Text version

FACID:

DRAWN:

DESIGNED:

DPW - CAD/ GIS BRANCH

99th READINESS DIVISION

SCALE:

CAD/GIS PROJ:CHECKED:

FIELD VERIFIED:

DATE:

SHEET:

REV:

DWG NO:

20NOV17

---REV 0: --

PA038 (42882)

NTSISSUED FOR REVIEW SJS

MLC SJS (18-02)

4X4 W4 / W4

WWR

IN CENTER OF WALL

WWR 4X4 W4 /W4

AND SHIPPING

(2) TYP FOR STRIPPING

WITH #6 TENSION BAR

8 TON ERECTION ANCHOR

SECTION VIEW

6. WEIGHT OF SECTION - APPROX. 21,500 lbs

CONFORM TO ASTM C913

5. MATERIALS AND MANUFACTURING SHALL

4. REINFORCING STEEL - ASTM A185

3. CONCRETE STRENGTH = 5000PSI MIN

2. DESIGN WIND LOAD = 17PSF (90 MPH)

1. DESIGN IS IN ACCORDANCE WITH ACI 318 ELEVATION VIEW

PLAN VIEW

NOTES:

(2) TYPE FOR SETTING

WITH #6 TENSION BAR

8 TON ERECTION ANCHOR

6'-0"

2'-0" TYP

1'-0 1/2 "

8'-4"

15'-0"

7"

HOOK

8" MIN

6"

2"COV

8"

10"

1'-11 1/2 " 1'-11 1/2 "

9"

8" 8"

PORTABLE PRECAST CONCRETE BARRIER

CONCRETE BARRIER WALL

PA038 LTA - KEYSTONE CONNEAUT LAKE (GENEVA)

" SHIP-LAP JOINT, TYP2

8'