WV006-Cross_Lanes-C9-CSS_9035-Schedule_PNL_A-Replace_Circuit_Breakers.xlsx

XLSX spreadsheet 17 KB Posted

Attached to
Replace Circuit Breakers in Training Building in Cross Lanes, WV 25313 Federal contract opportunity
Solicitation number
W15QKN-18-Q-1120
Issued by
Department of the Army Materiel Command Contracting Command Picatinny Arsenal

About this file

Schedule-Panel A

View the file

Other files for this federal contract opportunity

Other files attached to Replace Circuit Breakers in Training Building in Cross Lanes, WV 25313, newest first.
File Type Posted
Amendment_0001_to_Solicitation_W15QKN-18-Q-1120_Released.pdf PDF
WV006-Cross_Lanes-C9-CSS_9035-First_Floor_Lighting_Plan.pdf PDF
WV006-Cross_Lanes-C9-CSS_9035-Schedule_PNL_L-Replace_Circuit_Breakers.xlsx XLSX spreadsheet
WV006-Cross_Lanes-C9-CSS_9035-Schedule_PNL_E-Replace_Circuit_Breakers.xlsx XLSX spreadsheet
WV006-Cross_Lanes-C9-CSS_9035-Schedule_PNL_J-Replace_Circuit_Breakers.xlsx XLSX spreadsheet
WV006-Cross_Lanes-C9-CSS_9035-Second_Floor_Lighting_Plan.pdf PDF
WV006-Cross_Lanes-C9-CSS_9035-First_Floor_Power_Plan.pdf PDF
Solicitation_W15QKN-18-Q-1120_SF1442_Released.pdf PDF
WV006-Cross_Lanes-C9-CSS_9035-Schedule_PNL_G-Replace_Circuit_Breakers.xlsx XLSX spreadsheet
WV006-Cross_Lanes-C9-CSS_9035-Schedule_PNL_D-Replace_Circuit_Breakers.xlsx XLSX spreadsheet
WV006-Cross_Lanes-C9-CSS_9035-Schedule_PNL_B-Replace_Circuit_Breakers.xlsx XLSX spreadsheet
WV006-Cross_Lanes-C9-CSS_9035-Schedule_PNL_H-Replace_Circuit_Breakers.xlsx XLSX spreadsheet
WV006-Cross_Lanes-C9-CSS_9035-Schedule_PNL_K-Replace_Circuit_Breakers.xlsx XLSX spreadsheet
WV006-Cross_Lanes-C9-CSS_9035-Second_Floor_Power_Plan.pdf PDF
WV006-Cross_Lanes-C9-CSS_9035-Schedule_PNL_F-Replace_Circuit_Breakers.xlsx XLSX spreadsheet
WV006-Cross_Lanes-C9-CSS_9035-Schedule_PNL_C-Replace_Circuit_Breakers.xlsx XLSX spreadsheet
WV006-Cross_Lanes-C9-CSS_9035-SOW-Replace_Circuit_Breakers.doc DOC document
Show all 17

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Panel A
3 Phase 4 wire 225A 120V/208V MLO8/30/17
Min. AIC Raiting 10,000 RMS.
Circuit #Description:PoleAmpABCPoleAmpDescription:Circuit #
1Room 164, 168 Lights120A22.81120ARoom 174 Lights2
3See Note 1 Below.120A27120AEast Wall Security Lts.4
5See Note 2 Below.120A16.85120ASouth Wall Security Lts6
7See Note 3 Below.120A GFI15.95120ASee Note 6 Below.8
9See Note 4 Below.120A25.5120ARm. 171, 172, 173 Rec.10
11Rm. 171, 172, 173 Lts120A27120A GFIRoom 174 Rec.12
13Room 175, 183 Rec.120A27.5120ARoom 182, 183 Rec.14
15Mech. Rm. 181 Rec.120A GFI16.4120ARm. 181 Telephone Rm16
17See Note 5 Below.120A4120ARoom 174 EF-718
19Room 173 EF-9115A4.65120A GFISee Note 7 Below.20
21Room 181 EF-10115A5.5120ARoom 182, EF-11.22
23Room 175 Rec.115A5.5120A GFIRoom 178, EF-1324
25Room 178 EF-13A120A GFI12.5120ARm. 181 Circ. Pump26
271/3 HP Pumps120A17.15120ABoiler #428
291 HP Pumps120A19.6120AHVAC Controls30
313Q Electric Heater120ARm. 171, EF-832
333Q Electric Heater120A GFIDamage Cont. 171 Rec.34
353Q Electric Heater120AFlag Pole Photo Cell36
37WTR HTR Burner 1/4 HP115A5.8120ABoiler #138
39Spare120A120ABoiler #240
41Spare120A120ABoiler #342
Totals:89.2191.5572.95
Note 1:Rooms 171, 172, 173, 160, 170 Lights.
Note 2:Rooms 176, 181, 182, 180, 183, 184 Lights.
Note 3:Rooms 177, 178, 179 Damage Control Lights.
Note 4:Room 170, 176 Rec.,Room 181 LED Sign, Sprinkler Flow Alarm.
Note 5:Room 173, 174 UH-3, Room 183 EF-12.
Note 6:North Wall Security Lights, LED Signs Rooms 180, 177, 17?.
Note 7:Rooms 176, 181, 182, 184 UH-4.