This document is a set of plan drawings for the Winter Street Storm Improvements project prepared by Civil Solutions Engineering, LLC for the City of Roseburg Public Works Department in Roseburg, Oregon. The project, numbered 26.18/26PW15, involves the installation of a new storm drain system on N.E. Winter Street and N.E. Brooklyn Avenue, including approximately 217 linear feet of 12-inch corrugated plastic pipe (CPP) storm drain on Winter Street with a 13.5% slope, storm drain manholes, curb inlet catch basins equipped with water quality filter systems, and related infrastructure improvements. The project site is located at N.E. Winter Street, Roseburg, Oregon 97470, with Map ID 27-05W-07CD-06300. The drawing set includes plan views, profiles, standard details for storm drain components, and street improvement plans covering approximately 4+00 stations on Winter Street and 2+45 stations on Brooklyn Avenue. The engineer, James W. Norrington, P.E., certified the drawings as of June 2, 2010, with revisions noted on November 19, 2026.
The project specifications require adherence to the 2024 Oregon Standard Specifications for Construction (ODOT/APWA) with the Technical Specifications taking precedence where conflicts exist. Construction activities include trench backfill (Class B material in rights-of-way and parking lots; Class A elsewhere), placement of insulated copper toning wire in all trenches, compaction testing on mainline trenches and base rock materials, concrete work for driveways and sidewalks meeting ODOT/APWA specifications (4,000 PSI with fibermesh or rebar for driveways; 3,300 PSI for sidewalks and curb and gutter), and asphalt concrete overlay and pavement work. The contractor must contact the Oregon Utility Notification Center (811 or 1-800-332-2344) at least 48 hours prior to any excavation and comply with OAR 952-001-0090 regarding utility notification. City of Roseburg Public Works Department inspection is required at multiple stages including storm sewer construction, concrete work, finish base course grade, television inspection of storm drainage prior to paving, and final paving, with notification required 24 hours prior (phone: 541-492-6730; fax: 672-2785). The project specifications address asbestos-containing materials that may be present in existing underground pipe systems, requiring DEQ-licensed abatement contractors for friable asbestos removal and compliance with all relevant federal, state, county, and municipal regulations.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Volume 2 Technical Specifications.pdf | ||
| Specification Documents~1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT NO. 26.18 / 26PW15
PROJECT VICINITY MAP
NOVEMBER, 2026
WINTER STREET STORM IMPROVEMENTS
SITE ADDRESS:
CLIENT:
N.E. WINTER ST,
ROSEBURG, OREGON
97470
MAP ID: 27-05W-07CD-06300
ENGINEER:
CIVIL SOLUTIONS ENGINEERING, LLC
445 S. CALAPOOIA ST.
SUTHERLIN, OREGON
97479
PH: (541) 529-2002
EMAIL: JAMES@CSELLC.NET
ROSEBURG PUBLIC WORKS
900 S.E. DOUGLAS AVE.
ROSEBURG, OREGON
97470
/E
XE
IP R S 21
62/31
80160PE
OREGON
E
E
GN
I N
E
R
REG
ISTERED PROFESS IONAL
JAMES W . NORR I NGTO
NJ UNE 0 2 , 2 0 10
GENERAL
INDEX TO DRAWINGS
DWG NO. SHEET NO. DESCRIPTION
DETAILS
CIVIL
N.E. WINTER ST.
N .E
. B R
O O
K
LY
N A
V E.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE IN FEET
AutoCAD SHX Text T.L. 6300
AutoCAD SHX Text N
AutoCAD SHX Text 1 G1 PROJECT VICINITY MAP & INDEX TO DRAWINGS G1 PROJECT VICINITY MAP & INDEX TO DRAWINGS PROJECT VICINITY MAP & INDEX TO DRAWINGS 2 G2 LEGEND, ABBREVIATIONS, & GENERAL NOTES G2 LEGEND, ABBREVIATIONS, & GENERAL NOTES LEGEND, ABBREVIATIONS, & GENERAL NOTES 3 G3 GENERAL STREET & STORM DRAIN NOTES G3 GENERAL STREET & STORM DRAIN NOTES GENERAL STREET & STORM DRAIN NOTES
AutoCAD SHX Text 8 SD1 STORM DRAIN STANDARD DETAILS SD1 STORM DRAIN STANDARD DETAILS STORM DRAIN STANDARD DETAILS 9 SD2 STORM DRAIN STANDARD DETAILS (CONTINUED) SD2 STORM DRAIN STANDARD DETAILS (CONTINUED) STORM DRAIN STANDARD DETAILS (CONTINUED) 10 M1 MISCELLANEOUS DETAILS M1 MISCELLANEOUS DETAILS MISCELLANEOUS DETAILS 11 M2 MISCELLANEOUS DETAILS (CONTINUED)M2 MISCELLANEOUS DETAILS (CONTINUED)MISCELLANEOUS DETAILS (CONTINUED)
AutoCAD SHX Text 4 C1 N.E. WINTER ST. - STORM DRAIN PLAN (STA. 0+00 TO STA. 4+00) C1 N.E. WINTER ST. - STORM DRAIN PLAN (STA. 0+00 TO STA. 4+00) N.E. WINTER ST. - STORM DRAIN PLAN (STA. 0+00 TO STA. 4+00) 5 C2 N.E. BROOKLYN AVE. - STORM DRAIN PLAN (STA. 0+00 TO STA. 2+45) C2 N.E. BROOKLYN AVE. - STORM DRAIN PLAN (STA. 0+00 TO STA. 2+45) N.E. BROOKLYN AVE. - STORM DRAIN PLAN (STA. 0+00 TO STA. 2+45) 6 C3 N.E. WINTER ST. - STREET IMPROVEMENT PLAN (STA. 1+00 TO STA. 4+00) C3 N.E. WINTER ST. - STREET IMPROVEMENT PLAN (STA. 1+00 TO STA. 4+00) N.E. WINTER ST. - STREET IMPROVEMENT PLAN (STA. 1+00 TO STA. 4+00) 7 C4 N.E. BROOKLYN AVE. - STREET IMPROVEMENT PLAN (STA. 0+36 TO STA. 1+85)C4 N.E. BROOKLYN AVE. - STREET IMPROVEMENT PLAN (STA. 0+36 TO STA. 1+85)N.E. BROOKLYN AVE. - STREET IMPROVEMENT PLAN (STA. 0+36 TO STA. 1+85)
AutoCAD SHX Text
PROPOSED PROJECT LIMITS
AutoCAD SHX Text T.L. 6200
AutoCAD SHX Text T.L. 9100
AutoCAD SHX Text T.L. 9200
AutoCAD SHX Text T.L. 7600
AutoCAD SHX Text T.L. 7700
AutoCAD SHX Text T.L. 7800
AutoCAD SHX Text T.L. 7900
AutoCAD SHX Text T.L. 8000
AutoCAD SHX Text T.L. 8100
AutoCAD SHX Text T.L. 8200
AutoCAD SHX Text T.L. 8400
AutoCAD SHX Text T.L. 8500
AutoCAD SHX Text T.L. 9000
AutoCAD SHX Text T.L. 8900
AutoCAD SHX Text T.L. 8800
AutoCAD SHX Text T.L. 8700
AutoCAD SHX Text T.L. 8600
AutoCAD SHX Text T.L. 11200
AutoCAD SHX Text T.L. 7500
AutoCAD SHX Text T.L. 7400
LINE IS 1 INCH
AT FULL SCALE
DESIGNED: DRAWN: REVISIONS
IF NOT 1-INCH - SCALE ACCORDINGLY
DRAWING NO.
SHEET NO.DATE
PROJECT NO.
APPROVED BY:
DATE: LEGEND, ABBREVIATIONS, & GENERAL NOTES
WINTER STREET STORM IMPROVEMENTS
/E
XE
IP R S 21
62/31
80160PE
OREGON
E
E
GN
I N
E
R
REG
ISTERED PROFESS IONAL
JAMES W . NORR I NGTO
NJ UNE 0 2 , 2 0 1 0
11OF
JWN 26.18
NOV/2026
G2
NJC
CITY OF ROSEBURG PUBLIC WORKS DEPARTMENT
DRAWN ON DWG NO.
SECTION DESIGNATION
DRAWN ON DWG NO.
DETAIL DESIGNATION
REFERENCE SYMBOLS
AIR RELEASE VALVEARV
HB HOSE BIB
SVC SERVICE
SLAB-ON-GRADESOG
REDUCERRDCR
PIPE SUPPORTPS
PLUG VALVEPV
JUNCTION BOXJB
FINAL EFFLUENTFE
FLANGE COUPLING ADAPTERFCA
HIGH DENSITY POLYETHYLENEHDPE
TOE TOE OF BANK
TOP BACK CURBTBC
NIC NOT IN CONTRACT
VAR VARIES
DIAMETERØ
SOUTH(S)
NORTH(N)
EAST(E)
WEST(W)
STATIONSTA
LEFTLT
CUL CULVERT
RT RIGHT
LAT LATERAL
VALVEVLV
ADAPTERADPTR
GATE VALVEGV
FIRE HYDRANTFH
SANITARY DRAINSD
SANITARY SEWERSS
YARD
WITHOUT
WITH
GAWSA WATER POTABLE
STORM DRAIN
STAINLESS STEEL
SPECIFICATIONS
RIGHT OF WAY
REQUIRED
PAVEMENT
POUNDS PER SQUARE FOOT
PRESSURE
PLATE
PERFORATED
OVERFLOW
MINIMUM
MECHANICAL
MAXIMUM
MATERIAL
YD
W/O W/
W
STD
SST
SPEC
ROW
REQ'D
PVMT
PSF
PRESS.
PL
PERF
OF
MIN
MECH
MAX
MAT/MATL
LOWPOINT
INTERIOR
INVERT
HIGH POINT
HORIZONTAL
FOOTING
EXTERIOR
EXISTING
EACH WAY
ELBOW
EACH
DIMENSION
DIAMETER
CENTER
COUPLING
CORPORATION
CLEAN OUT
CATCH BASIN
BENCH MARK
APPROXIMATE
ALUMINUM
ANCHOR BOLT
LPT
INT
INV
HPT
HORIZ
FTG
EXT
EXIST./EX.
EW
ELB
EA
DIM
DIA
CTR
CPLG
CORP
CO
CB
CARV
BM
APPROX
AL
AB
AUX
AGG
AUXILIARY
AGGREGATE
POWER POLE/UTILITY POLEP/P
MANHOLE
MANUFACTURER
LINEAR FEET
LENGTH
HEIGHT
HORSE POWER
POWER INPUT
PLAIN END
ON CENTER
NOT TO SCALE
MASTER
REINFORCING
RADIUS
POLYVINYL CHLORIDE
POUNDS PER SQUARE INCH
PUMPING STATION
PRESSURE MAIN
PHASE (ELEC)/PUMP
OUTSIDE DIAMETER
TYPICAL
THREADED
SUBMERSION
SQUARE
STEEL
SECTION
SCHEDULE
MECHANICAL JOINT
L
HT
HP
MH
MFR/MANUF
LF
OC/O.C.
NTS
MSTR
PI
PE
P
OD
P/S
PM
REINF
R
PVC
PSI
STL
SEC
SCH
TYP
THD
SUBM
SQ
MJ
AIR
CI
C
BLDG
BKFL
AC
A
CAST IRON
CONDUIT
BUILDING
BACKFILL
ASPHALTIC CONCRETE
DRAIN
FD
ELEC
EL/ELEV
EFF
D/W
DIP
DET
D
CONT
CONST
CONN
CONC
CNTRL
CMP
FEET
FM
GPD,H,M
GND
GIP
GALV
FT
FLG
FF/FIN. FLR.
FORCE MAIN
GROUND (ELEC)
GALVANIZED IRON PIPE
GALVANIZED
FLANGED
FINISH FLOOR
FLOOR DRAIN
ELECTRICAL
ELEVATION
EFFLUENT
DISHWASHER
DUCTILE IRON PIPE
DETAIL
CONTINUOUS
CONSTRUCTION
CONNECTION
CONCRETE
CONTROL
CORRUGATED METAL PIPE
ABBREVIATIONS
TRANS TRANSITION
IE INVERT ELEVATION
FIBER OPTICFO
EDGE OF PAVEMENTEOP
FOC FACE OF CURB
FINISH GRADEFG
TOB TOP OF BANK
GENERAL NOTES
TRANSITION COUPLINGTCPLG
UNDERGROUND SERVICE ALERT
ONE-CALL NUMBER
CALL TWO BUSINESS DAYS
BEFORE YOU DIG
NEW
LINES AND NOTATIONS USED TO IDENTIFY NEW CONSTRUCTION OR IMPROVEMENTS TO EXISTING FACILITIES VARY.
REFER TO SITE SPECIFIC PLAN DRAWING SHEETS FOR IDENTIFICATION OF NEW CONSTRUCTION AND/OR IMPROVEMENTS
IN THAT PARTICULAR AREA.
DR DRAIN
RECLAIMED WATERRCL
UNLESS OTHERWISE NOTEDUON
DUCTILE IRONDI
TOP OF WALLTOW
CL CHLORINE
TOP OF FOOTINGTOF
SUPERNATANTSN
TS TRANSFER SLUDGE
DS DIGESTED SLUDGE
HOT WATERHW
PUMPED DRAINAGEPD
RETURN ACTIVATED SLUDGERAS
RS RAW SEWAGE
SECONDARY EFFLUENTSE
TD TANK DRAIN
WASTE ACTIVATED SLUDGEWAS
HIGH WATER LEVELHWL
LOW WATER LEVELLWL
NON-POTABLE WATERNPW
CMU CONCRETE MASONRY UNIT
CFM CUBIC FEET PER MINUTE
FL FLOWLINE
TEMPORARY BENCH MARKTBM
LONGLG
PRESSATEPST
POINT OF CURVATUREPC
1.
2.
CONTRACTORS NOTIFICATION REQUIREMENTS LAW
THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES, AS SHOWN ON THESE PLANS, IS BASED ON FIELD LOCATES AND RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE MEASUREMENTS IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED UPON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CONTACT "ONE-CALL" AT 811. THE TELEPHONE NUMBER FOR THE OREGON UTILITY NOTIFICATION CENTER IS (503) 232-1987. FOR UTILITY LOCATES AT LEAST 48 HOURS BEFORE ANY EXCAVATION. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS ESPECIALLY AT CONNECTIONS AND AT POTENTIAL
UTILITY CONFLICTS.
THE OVERHEAD ELECTRIC LOCAL DISTRIBUTION SYSTEMS AND INDIVIDUAL SERVICE LINES ARE NOT SPECIFICALLY INDICATED ON THE DRAWINGS. THE CONTRACTOR SHALL EXERCISE CAUTION WHILE
WORKING NEAR, OR UNDER, ALL ELECTRIC LINES.
THE BASIS OF BEARING WAS DERIVED FROM THE THE OREGON COORDINATE REFERENCE SYSTEM (OCRS), VERTICAL DATUM IS BASED ON NAVD 88.
TF TERTIARY FILTER
STORM HIGH WATER LEVELSHWL
BOTTOM WATER LEVELBWL
DB DIGESTED BIOSOLIDS
G GRIT
PLYWOODPLYWD
RW REUSE WATER
SERVICE AIRSA
TE TERTIARY EFFLUENT
VENTV
TOP OF SLABTOS
C
RESTRAINED FLANGE COUPLING ADAPTORRFCA
FRIG REFRIGERATOR
FACTORY FINISHFAC
FINISHFIN
FND FOUNDATION
EPOXY PAINTEP
EXISTING TO REMAINETR
EQUALEQ
DEMO DEMOLITION
DWG DRAWING
DST DOWNSPOUT
CV COVED
CLR CLEAR
CHEMICALCHEM
BLKG BLOCKING
BRICKBR
BD BOARD
ACOUSTICAL TILEAT
APPLIED ATATA
MOISTURE RESISTANT ATATMR
RUBBER BASERB/RBR
RESTROOMR/R
REFERENCEREF
REQUIREMENTSREQ'S
POLYMERPOL
PAINTPNT
PRESSURE TREATEDP.T.
OVERHEADOH
METALMTL
MANUFACTURINGMFG
LB POUND
INFO INFORMATION
H HEIGHT
GB/GYP.BD. GYPSUM BOARD
GBX MOISTURE RESISTANT GB
GFI GROUND FAULT INTERRUPTER
GL GLAZING
WOODWD
URETHANE FOAMUF
T.O. TOP OF
TEMP TEMPERED
SEALED CONCRETESC
SIMILARSIM
SEALED PLYWOODSP
SHEATHINGSTHNG
COMBINATION AIR RELEASE
VALVE
GALLONS PER DAY, HOUR, MINUTE
DEC DOUGLAS ELECTRIC COOP
VG VALLEY GUTTER
VENT TO ROOFVTR
UV TRANSMITTANCEUVT
WOVEN WIRE MESHWWM
INFLUENT PUMP STATIONIPS
INFLUENT SCREENING FACILITYISF
ATTENTION: OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED BY THE OREGON UTILITY
NOTIFICATION CENTER. THOSE RULES ARE SET FORTH IN OAR-952-001-0090. YOU MAY OBTAIN COPIES OF
THE RULES BY CALLING THE CENTER.
OVER-TORQUEOT
STREAMING CURRENT MONITORSCM
3.
PROPERTY LINEP.L./
TFOC TOP FACE OF CURB
PL
T.L. TAX LOT
TOP OF CURBTC
LINE TYPE & SYMBOL LEGEND
EXISTING
WATER METERWM
MONUMENTMON
T.O.P. TOP OF PIPE
AutoCAD SHX Text
APPR'D.
AutoCAD SHX Text
SUBMIT.
AutoCAD SHX Text
REVISED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text C:\Users\ncata\Civil Solutions Engineering\Communication Site - Documents\Active Projects\2026 Projects\26.18 Winter St. SD Improvements\Design\DWG\WINTER ST.& STORM_LAYOUTS_5-14-26.dwg, 11/20/2026 10:22:56 AM , 11/20/2026 10:22:56 AM 11/20/2026 10:22:56 AM
AutoCAD SHX Text CIVIL SOLUTIONS ENGINEERING, LLC 445 S. CALAPOOIA ST. SUTHERLIN, OREGON 97479 TELEPHONE: (541) 529-2002 JAMES@CSELLC.NET
AutoCAD SHX Text
EXISTING EDGE OF PAVEMENT
AutoCAD SHX Text
EXISTING EDGE OF GRAVEL
AutoCAD SHX Text
EXISTING FENCE
AutoCAD SHX Text
EXISTING COMMUNICATIONS
AutoCAD SHX Text
EXISTING WATERLINE
AutoCAD SHX Text
EXISTING STORM DRAIN
AutoCAD SHX Text
EXISTING SANITARY SEWER
AutoCAD SHX Text C
AutoCAD SHX Text
EXISTING COMMUNICATION PEDESTAL
AutoCAD SHX Text E
AutoCAD SHX Text
EXISTING ELECTRICAL PEDESTAL
AutoCAD SHX Text
SD
AutoCAD SHX Text
EXISTING STORM DRAIN MAN HOLE
AutoCAD SHX Text
SS
AutoCAD SHX Text
EXISTING SANITARY SEWER MANHOLE
AutoCAD SHX Text
EXISTING SHRUBBERY
AutoCAD SHX Text
EXISTING TREE
AutoCAD SHX Text
EXISTING HYDRANT
AutoCAD SHX Text E
AutoCAD SHX Text
EXISTING ELECTRICAL METER
AutoCAD SHX Text
EXISTING SIGN
AutoCAD SHX Text
EXISTING GUY STAKE
AutoCAD SHX Text
EXISTING CLEANOUT
AutoCAD SHX Text
CO
AutoCAD SHX Text
EXISTING POWER POLE
AutoCAD SHX Text
WV
AutoCAD SHX Text
EXISTING WATER VALVE
AutoCAD SHX Text
EXISTING WATER METER
AutoCAD SHX Text W
AutoCAD SHX Text
EXISTING AC PAVEMENT
AutoCAD SHX Text
EXISTING GRAVEL
AutoCAD SHX Text
EXISTING GRASS
AutoCAD SHX Text
EXISTING CONCRETE
AutoCAD SHX Text
EXISTING PROPERTY BOUNDARY
AutoCAD SHX Text
COMS
AutoCAD SHX Text
EXISTING MONUMENT
AutoCAD SHX Text
EXISTING UNDERGROUND POWER
AutoCAD SHX Text
SD
AutoCAD SHX Text
SS
AutoCAD SHX Text
JWN
AutoCAD SHX Text
JWN
AutoCAD SHX Text 11/19/26
AutoCAD SHX Text
CITY REVIEW COMMENTS
DESIGNED: DRAWN: REVISIONS
IF NOT 1-INCH - SCALE ACCORDINGLY
DRAWING NO.
SHEET NO.DATE
PROJECT NO.
APPROVED BY:
DATE: GENERAL STREET & STORM DRAIN NOTES/E
XE
IP R S 21
62/31
80160PE
OREGON
E
E
GN
I N
E
R
REG
ISTERED PROFESS IONAL
JAMES W . NORR I NGTO
NJ UNE 0 2 , 2 0 1 0
11OF
JWN 26.18
NOV/2026
G3
NJC
GENERAL NOTES
1. THE PROJECT TECHNICAL SPECIFICATIONS SHALL GOVERN. THE 2024 OREGON STANDARD SPECIFICATIONS FOR CONSTRUCTION (ODOT/APWA) SHALL APPLY TO ALL WORK NOT ADDRESSED IN THE TECHNICAL SPECIFICATIONS. WHERE THE TWO CONFLICT, THE TECHNICAL
SPECIFICATIONS SHALL TAKE PRECEDENCE.
2. TRENCH BACKFILL SHALL BE CLASS B (1"-0" CRUSHED ROCK) WITHIN ALL STREET RIGHT-OF-WAYS AND UNDER ALL PARKING LOTS, AND CLASS A (SUITABLE EXCAVATED MATERIAL) ELSEWHERE, UNLESS SHOWN DIFFERENT ON TRENCH DETAIL OR IN SPECIFICATIONS. ALL TRENCHES WILL
BE COMPACTED WITH HAND-OPERATED PNEUMATIC COMPACTOR.
3. THE CONTRACTOR SHALL REPLACE ANY AND ALL SURVEY MONUMENTS WHICH ARE AFFECTED BY THE CONSTRUCTION. ALL MONUMENTS WILL
BE RESET BY A LICENSED LAND SURVEYOR.
4. LOCATIONS SHOWN ON ENGINEERING DRAWINGS ARE APPROXIMATE. THE EXACT LOCATION WILL BE STAKED IN THE FIELD BY THE OWNERS
CHOSEN SURVEYOR OR CONSTRUCTION CONTRACTOR.
5. INSULATED COPPER TONING WIRE APPROVED FOR DIRECT BURY SHALL BE PLACED IN ALL TRENCHES WHERE PIPE HAS BEEN LAID. ALL TONE
WIRE SHALL BE TESTED PRIOR TO ACCEPTANCE.
6. THE CONTRACTOR SHALL NOTIFY ALL AFFECTED UTILITY COMPANIES FOR LOCATIONS OF MAINLINE AND SERVICE LINE LOCATIONS PRIOR TO DIGGING. CONTRACTOR TO CONTACT ONE-CALL AT LEAST 48 HOURS PRIOR TO CONSTRUCTION AT 1-800-332-2344.
ATTENTION:
OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED BY THE OREGON UTILITY NOTIFICATION CENTER. THOSE RULES ARE SET FORTH IN THE OAR 952-001-0010 THROUGH OAR 952-001-0090. YOU MAY OBTAIN COPIES OF THE RULES BY CALLING THE CENTER. (NOTE: THE ADMINISTRATIVE TELEPHONE NUMBER FOR THE OREGON UTILITY NOTIFICATION CENTER IS (503) 232-1987).
7. ENGINEER AND CITY TO BE NOTIFIED FOR INSPECTION AS SHOWN ON SCHEDULE OR AS SPECIFIED IN "GENERAL NOTES" FOR THAT SPECIFIC
CONSTRUCTION ITEM.
8. CONTRACTOR TO FIELD VERIFY TYPE, LOCATION, AND ELEVATIONS OF EXISTING UNDERGROUND UTILITIES PRIOR TO INSTALLATION OF NEW
PIPING.
9. CONTRACTOR RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS FOR WORKING IN PUBLIC RIGHT-OF-WAYS. (i.e. ODOT, CITY, COUNTY).
10. COMPACTION TESTING IS REQUIRED ON ALL MAINLINE TRENCHES, SUBGRADE AND BASE ROCK MATERIALS. TESTING SHALL CONFORM TO
SECTION 00405 FOR TRENCHES AND SECTION 00330 FOR SUBGRADE. AGGREGATE BASE MATERIAL SHALL BE PLACED IN CONFORMANCE WITH SECTION 00640 WITH THE EXCEPTION THAT COMPACTION OF EACH LAYER SHALL BE CONTINUED UNTIL A DENSITY OF NOT LESS THAT 95% OF MAXIMUM DENSITY AS DETERMINED BY AASHTO T99 (OR 90% AS DETERMINED BY ASTM D 1557 (OR AASHTO T 180)). FREQUENCY OF TESTING SHALL BE A MINIMUM OF 3 TESTS PER LIFT. WHEN QUANTITY EXCEEDS 2000 TONS PER LIFT, THEN ADDITIONAL TESTING IS REQUIRED AT THE RATE OF 3 TESTS PER 2000 TONS. ALL TEST RECORDS SHALL BE SUBMITTED TO THE ENGINEER BY THE FOLLOWING DAY.
11. STANDARD DRAWINGS SHOWN ON PLANS ARE SUBJECT TO CHANGE WITHOUT NOTIFICATION. CONTRACTOR TO VERIFY WITH AGENCY PRIOR
TO CONSTRUCTION.
GENERAL STREET IMPROVEMENTS NOTE
1. CONCRETE FOR DRIVEWAYS AND SIDEWALKS IN PUBLIC RIGHT-OF-WAY SHALL MEET ODOT/APWA SPECIFICATIONS. DRIVEWAYS SHALL BE 4,000 PSI WITH FIBERMESH OR REBAR, SIDEWALKS AND CURB & GUTTER SHALL BE 3,300 PSI STRENGTH.
CITY PUBLIC WORKS INSPECTION SCHEDULE
CITY OF ROSEBURG SHALL BE NOTIFIED FOR INSPECTION OF PUBLIC FACILITIES AT LEAST 24 HOURS PRIOR TO THE ACCOMPLISHMENT OF THE
FOLLOWING STAGES OF CONSTRUCTION.
PHONE: 541-492-6730. FAX: 672-2785.
1. ANY STORM SEWER CONSTRUCTION (INCLUDING STRUCTURES)
2. SOIL STABILIZATION FABRIC INSTALLATION
3. ANY CONCRETE WORK
4. FINISH BASE COURSE GRADE
5. TELEVISION INSPECTION OF STORM DRAINAGE (PRIOR TO PAVING)
6. PAVING
NONE OF THE ABOVE ITEMS OF WORK SHALL BE COVED UNTIL INSPECTED BY THE CITY OF ROSEBURG PUBLIC WORKS DEPARTMENT
ASBESTOS SPECIAL NOTE
1. MATERIALS CONTAINING ASBESTOS MAY BE PRESENT IN UNDERGROUND PIPE SYSTEMS. ALL APPROPRIATE FEDERAL, STATE, COUNTY, AND MUNICIPAL RULES, REGULATIONS AND GUIDELINES MUST BE FOLLOWED WHEN WORKING WITH ASBESTOS-CONTAINING MATERIAL. NONFRIABLE MATERIAL MUST BE HANDLED, TRANSPORTED AND DISPOSED OF IN A WAY THAT PREVENTS IT FROM BECOMING FRIABLE AND RELEASING ASBESTOS FIBERS. IF AC PIPE IS SHATTERED, DAMAGED, OR BADLY WEATHERED, IT IS CONSIDERED TO BE FRIABLE AND WILL LIKELY RELEASE ASBESTOS FIBERS. DEQ LICENSED ASBESTOS ABATEMENT CONTRACTOR USING DEQ CERTIFIED WORKERS MUST REMOVE ALL FRIABLE ASBESTOS MATERIAL. ANY AND ALL PERMITS AND FEES THAT ARE REQUIRED BY THE DEQ, DOUGLAS COUNTY, AND ANY OTHER REGULATORY AGENCY MUST BE OBTAINED BY THE CONTRACTOR PRIOR TO DISPOSING OF THE ASBESTOS CONTAINING MATERIAL. FOR INFORMATION ABOUT
ASBESTOS RULES, CONTACT THE DEQ WESTERN REGION OFFICE IN MEDFORD, OREGON.
UTILITY COMPANIES & CONTACTS
AVISTA UTILITIES RYAN FORSLOFF 541-440-1162
P.O. BOX 1520 CORPORATE OFFICE 800-227-9187
ROSEBURG, OR 97470
CENTURY LINK CHRISTOPHER J. SILBA 541-608-4511
CHARTER COMMUNICATIONS ROD JUSTICE 541-464-6185
575 W. HARRISON
ROSEBURG, OR 97471
COMSPAN MARY ROBERTS 541-229-0229
1016 S.E. OAK
ROSEBURG, OR 97470
DOUGLAS FAST NET TODD WAY 541-673-4242
480 OAKLAND AVE., N.E.
ROSEBURG, OR 97470
PACIFIC POWER SHANNON WATSON 541-679-3671
4025 OLD HWY 99 SOUTH MARTHA WARNER 541-679-3642
ROSEBURG, OR 97470
ROSEBURG, CITY OF NIKKI MESSENGER 541-492-6730
900 S.E. DOUGLAS
ROSEBURG, OR 97470
RUSA JIM BAIRD 541-672-1551
1297 N.E. GRANDVIEW
P.O. BOX 1185
ROSEBURG, OR 97470
COMPANY CONTACT PHONE
WINTER STREET STORM IMPROVEMENTS
CITY OF ROSEBURG PUBLIC WORKS DEPARTMENT
AutoCAD SHX Text
APPR'D.
AutoCAD SHX Text
SUBMIT.
AutoCAD SHX Text
REVISED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text C:\Users\ncata\Civil Solutions Engineering\Communication Site - Documents\Active Projects\2026 Projects\26.18 Winter St. SD Improvements\Design\DWG\WINTER ST.& STORM_LAYOUTS_5-14-26.dwg, 11/20/2026 10:22:56 AM , 11/20/2026 10:22:56 AM 11/20/2026 10:22:56 AM
AutoCAD SHX Text CIVIL SOLUTIONS ENGINEERING, LLC 445 S. CALAPOOIA ST. SUTHERLIN, OREGON 97479 TELEPHONE: (541) 529-2002 JAMES@CSELLC.NET
AutoCAD SHX Text
JWN
AutoCAD SHX Text
JWN
AutoCAD SHX Text
CITY REVIEW COMMENTS
AutoCAD SHX Text
11/19/26
DESIGNED: DRAWN: REVISIONS
IF NOT 1-INCH - SCALE ACCORDINGLY
DRAWING NO.
SHEET NO.DATE
PROJECT NO.
APPROVED BY:
DATE: N.E. WINTER ST. - STORM DRAIN PLAN/E
XE
IP R S 21
62/31
80160PE
OREGON
E
E
GN
I N
E
R
REG
ISTERED PROFESS IONA L
JAMES W . NORR I NGTO
NJ UNE 0 2 , 2 0 1 0
11OF
JWN 26.18
NOV/2026
C1
NJC
STA. 0+00 TO STA. 4+00
PROFILE VIEW
CONTRACTORS NOTIFICATION REQUIREMENTS LAW
ATTENTION: OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED BY THE OREGON UTILITY NOTIFICATION CENTER.
THOSE RULES ARE SET FORTH IN OAR-952-001-0090. YOU MAY OBTAIN COPIES OF THE RULES BY CALLING THE CENTER.
0' 20' 40'
PLAN SCALE
C1
1PLAN VIEW - STA. 0+00 TO STA. 4+00
N .E
. B R
O O
K
LY
N A
V E.
N.E. WINTER ST.
2 3
WINTER STREET STORM IMPROVEMENTS
CITY OF ROSEBURG PUBLIC WORKS DEPARTMENT
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text
SS
AutoCAD SHX Text
SS
AutoCAD SHX Text
SS
AutoCAD SHX Text
CO
AutoCAD SHX Text
MB
AutoCAD SHX Text
MB
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
APPR'D.
AutoCAD SHX Text
SUBMIT.
AutoCAD SHX Text
REVISED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text C:\Users\ncata\Civil Solutions Engineering\Communication Site - Documents\Active Projects\2026 Projects\26.18 Winter St. SD Improvements\Design\DWG\WINTER ST.& STORM_LAYOUTS_5-14-26.dwg, 11/20/2026 10:22:56 AM , 11/20/2026 10:22:56 AM 11/20/2026 10:22:56 AM
AutoCAD SHX Text CIVIL SOLUTIONS ENGINEERING, LLC 445 S. CALAPOOIA ST. SUTHERLIN, OREGON 97479 TELEPHONE: (541) 529-2002 JAMES@CSELLC.NET
AutoCAD SHX Text
KEYED NOTES::
AutoCAD SHX Text STA. 0+99.05 (0.9') 0+99.05 (0.9') EXISTING SD MH RIM=686.23' EX. 6" CONC. (SW) IEI=682.87'EX. 6" CONC. (NE) IEI=681.01'EX. 6" CONC. (SE) IEI=680.50'NEW 12" CPP (S) IEI=679.53'EX. 24" CPP (E) IEI=680.67'EX. 24" ALUM. SPIRAL (W) IEO=678.88'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HORIZONTAL
AutoCAD SHX Text
VERTICAL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text GENERAL NOTES: : 1. ALL STORM DRAIN MANHOLES ARE TO HAVE A SOLID COVER UNLESS OTHERWISE STATED. ALL STORM DRAIN MANHOLES ARE TO HAVE A SOLID COVER UNLESS OTHERWISE STATED. 2. ALL NEW CURB INLET CATCH BASINS ARE TO BE FITTED WITH A WATER QUALITY FILTER ALL NEW CURB INLET CATCH BASINS ARE TO BE FITTED WITH A WATER QUALITY FILTER SYSTEM SUCH AS FLOGARD, FLEXSTORM OR APPROVED EQUAL. 3. CONTRACTOR TO POTHOLE EXISTING SS SERVICE LINES PRIOR TO ANY CONSTRUCTION CONTRACTOR TO POTHOLE EXISTING SS SERVICE LINES PRIOR TO ANY CONSTRUCTION ACTIVITIES. NOTIFY ENGINEER OF ANY POTENTIAL CONFLICTS WITH NEW SD PIPING. 4. FINISH GRADE SURFACE CONTOURS SHOWN.FINISH GRADE SURFACE CONTOURS SHOWN.
AutoCAD SHX Text 1+00
AutoCAD SHX Text 2+00
AutoCAD SHX Text
1 SD1
AutoCAD SHX Text 676'
AutoCAD SHX Text
SCALE: 1" = 40'
AutoCAD SHX Text N
AutoCAD SHX Text
TAX LOT 7500 (HOUSE # 1621)
AutoCAD SHX Text
TAX LOT 7600 (HOUSE # 1529)
AutoCAD SHX Text
TAX LOT 7700 (HOUSE # 1571)
AutoCAD SHX Text
TAX LOT 7800 (HOUSE # 1561)
AutoCAD SHX Text
TAX LOT 7900 (HOUSE # 1551)
AutoCAD SHX Text
TAX LOT 6300 (HOUSE # 1620)
AutoCAD SHX Text
TAX LOT 9100 (HOUSE # 1479)
AutoCAD SHX Text
TAX LOT 9000 (HOUSE # 1560)
AutoCAD SHX Text
TAX LOT 8900 (HOUSE # 1550)
AutoCAD SHX Text 680'
AutoCAD SHX Text 684'
AutoCAD SHX Text 688'
AutoCAD SHX Text 692'
AutoCAD SHX Text 696'
AutoCAD SHX Text 700'
AutoCAD SHX Text 704'
AutoCAD SHX Text 708'
AutoCAD SHX Text 712'
AutoCAD SHX Text 716'
AutoCAD SHX Text 720'
AutoCAD SHX Text 724'
AutoCAD SHX Text 672'
AutoCAD SHX Text 676'
AutoCAD SHX Text 680'
AutoCAD SHX Text 684'
AutoCAD SHX Text 688'
AutoCAD SHX Text 692'
AutoCAD SHX Text 696'
AutoCAD SHX Text 700'
AutoCAD SHX Text 704'
AutoCAD SHX Text 708'
AutoCAD SHX Text 712'
AutoCAD SHX Text 716'
AutoCAD SHX Text 720'
AutoCAD SHX Text 724'
AutoCAD SHX Text 672'
AutoCAD SHX Text 0+00
AutoCAD SHX Text 3+00
AutoCAD SHX Text 4+00
AutoCAD SHX Text
EX. PROPERTY LINE / R-O-W (TYP.)
AutoCAD SHX Text
NEW FINISH GRADE @ EX. ROAD CENTERLINE
AutoCAD SHX Text
EXISTING GRADE @ EX. ROAD CENTERLINE
AutoCAD SHX Text
NEW 12" CPP SD,LF=217.0', S=13.5%
AutoCAD SHX Text
STA. 2+21.02 EXISTING SS SERVICE
AutoCAD SHX Text
STA. 2+74.60 EXISTING SS SERVICE
AutoCAD SHX Text
STA. 3+07.04 EX. SS SERVICE
AutoCAD SHX Text
STA. 3+17.34 EX. WATER SERVICE
AutoCAD SHX Text
STA. 3+37.88 EXISTING SS SERVICE
AutoCAD SHX Text STA. 3+55 (0.0') NEW 48" SD MHRIM=720.8'±NEW 12" CPP (W) IEI=715.39'NEW 12" CPP (E) IEI=715.39'NEW 12" CPP (N) IEO=714.29'
AutoCAD SHX Text STA. 1+34 (0.0') NEW 48" SD MHRIM=688.9'±NEW 12" CPP (S) IEI=684.95'NEW 12" CPP (E) IEI=683.05'NEW 12" CPP (W) IEI=683.72'NEW 12" CPP (N) IEO=682.95'
AutoCAD SHX Text STA. 0+99.05 (0.9') EXISTING SD MH RIM=686.23' EX. 6" CONC. (SW) IEI=682.87'EX. 6" CONC. (NE) IEI=681.01'EX. 6" CONC. (SE) IEI=680.50'NEW 12" CPP (S) IEI=679.53'EX. 24" CPP (E) IEI=680.67'EX. 24" ALUM. SPIRAL (W) IEO=678.88'
AutoCAD SHX Text
NEW 12" CPP SD,LF=31.0', S=11.0%
AutoCAD SHX Text
STA. 1+05.46 (0.8') EX. 8" SS CROSSING,APPROX. IE=682.0'±
AutoCAD SHX Text 728'
AutoCAD SHX Text 728'
AutoCAD SHX Text EXISTING 6" STORM DRAIN TO BE DEMOLISHED & REMOVED WHEREENCOUNTERED, PLUG THE LAST TWO FEET OF EACH PIPE END WITH CONCRETE, GROUT OR CDF
AutoCAD SHX Text
NEW 12" CPP SD, LF=31.0', S=11.00%
AutoCAD SHX Text STA. 1+34 (0.0') NEW 48" SD MH PER DETAILRIM=688.9'±NEW 12" CPP (S) IEI=684.95'NEW 12" CPP (E) IEI=683.05'NEW 12" CPP (W) IEI=683.72'NEW 12" CPP (N) IEO=682.95'
AutoCAD SHX Text
NEW 12" CPP SD, LF=217.0', S=13.5%
AutoCAD SHX Text STA. 3+55 (0.0') 3+55 (0.0') NEW 48" SD MH PER DETAILRIM=720.8'±NEW 12" CPP (W) IEI=715.39'NEW 12" CPP (E) IEI=715.39'NEW 12" CPP (N) IEO=714.29'
AutoCAD SHX Text
2 SD1
AutoCAD SHX Text
2 SD1
AutoCAD SHX Text
NEW 12" CPP SD, LF=18.7', S=0.50%
AutoCAD SHX Text STA. 1+34.00 (-22.2') 1+34.00 (-22.2') NEW CURB INLET CATCH BASIN PER DETAIL RIM/TFOC=689.17' NEW 12" CPP (W) IEO=683.14' 18" SUMP=681.64'
AutoCAD SHX Text
NEW 12" CPP SD, LF=11.2', S=0.50%
AutoCAD SHX Text
NEW 12" CPP SD, LF=11.1', S=0.50%
AutoCAD SHX Text
1 SD2
AutoCAD SHX Text STA. 3+55.00 (-14.6') 3+55.00 (-14.6') NEW CURB INLET CATCH BASIN PER DETAIL RIM/TFOC=720.17' NEW 12" CPP (W) IEO=715.44' 18" SUMP=713.94'
AutoCAD SHX Text
1 SD2
AutoCAD SHX Text
NEW 12" CPP SD, LF=11.0', S=0.50%
AutoCAD SHX Text STA. 3+55.00 (14.5') 3+55.00 (14.5') NEW CURB INLET CATCH BASIN PER DETAIL RIM/TFOC=719.97' NEW 12" CPP (E) IEO=715.45' 18" SUMP=713.95'
AutoCAD SHX Text
1 SD2
AutoCAD SHX Text
EXISTING DRIVEWAY (TYP.)
AutoCAD SHX Text STA. 1+34.00 (14.7') REMOVE & DISPOSE OF EXISTING CATCH BASIN, PROVIDE NEW CURB INLET CATCH BASIN PER DETAIL RIM/TFOC=688.42' NEW 12" CPP (E) IEO=683.78'18" SUMP=682.28'
AutoCAD SHX Text
1 SD2
AutoCAD SHX Text RELOCATE EXISTING "DEAD END" SIGN ON A TEMPORARY BASIS AND RESTORE TO ORIGINAL LOCATION AT THE END OF CONSTRUCTION ACTIVITIES PER DETAIL
AutoCAD SHX Text
STA. 3+24.23 EXISTING GAS SERVICE
AutoCAD SHX Text
STA. 2+24.52 EXISTING GAS SERVICE
AutoCAD SHX Text
STA. 2+54.90 EXISTING GAS SERVICE
AutoCAD SHX Text 3 M1
AutoCAD SHX Text
SAWCUT EXISTING AC PAVEMENT AS REQUIRED FOR SD SYSTEM INSTALLATION PER DETAIL
AutoCAD SHX Text
1 SD1
AutoCAD SHX Text
(TYP.)
AutoCAD SHX Text
JWN
AutoCAD SHX Text
JWN
AutoCAD SHX Text
CITY REVIEW COMMENTS
AutoCAD SHX Text
PROFILE VIEW
LINE IS 1 INCH
AT FULL SCALE
DESIGNED: DRAWN: REVISIONS
IF NOT 1-INCH - SCALE ACCORDINGLY
DRAWING NO.
SHEET NO.DATE
PROJECT NO.
APPROVED BY:
DATE: N.E. BROOKLYN AVE. - STORM DRAIN PLAN/E
XE
IP R S 21
62/31
80160PE
OREGON
E
E
GN
I N
E
R
REG
ISTERED PROFESS IONAL
JAMES W . NORR I NGTO
NJ UNE 0 2 , 2 0 1 0
11OF
JWN 26.18
NOV/2026
C2
NJC
STA. 0+00 TO STA. 2+45
CONTRACTORS NOTIFICATION REQUIREMENTS LAW
ATTENTION: OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED BY THE OREGON UTILITY NOTIFICATION CENTER.
THOSE RULES ARE SET FORTH IN OAR-952-001-0090. YOU MAY OBTAIN COPIES OF THE RULES BY CALLING THE CENTER.
0' 20' 40'
PLAN SCALE
C2
1PLAN VIEW - STA. 0+00 TO STA. 2+45
N.E. BROOKLYN AVE.
N .E
. W
IN
TE
R
S T.
WINTER STREET STORM IMPROVEMENTS
CITY OF ROSEBURG PUBLIC WORKS DEPARTMENT
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text
SS
AutoCAD SHX Text
SS
AutoCAD SHX Text
MB
AutoCAD SHX Text
MB
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
MB
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HORIZONTAL
AutoCAD SHX Text
VERTICAL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
APPR'D.
AutoCAD SHX Text
SUBMIT.
AutoCAD SHX Text
REVISED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text C:\Users\ncata\Civil Solutions Engineering\Communication Site - Documents\Active Projects\2026 Projects\26.18 Winter St. SD Improvements\Design\DWG\WINTER ST.& STORM_LAYOUTS_5-14-26.dwg, 11/20/2026 10:22:56 AM , 11/20/2026 10:22:56 AM 11/20/2026 10:22:56 AM
AutoCAD SHX Text CIVIL SOLUTIONS ENGINEERING, LLC 445 S. CALAPOOIA ST. SUTHERLIN, OREGON 97479 TELEPHONE: (541) 529-2002 JAMES@CSELLC.NET
AutoCAD SHX Text
KEYED NOTES::
AutoCAD SHX Text
STA. 0+69.01 EX. WATER SERVICE
AutoCAD SHX Text
SCALE: 1" = 20'
AutoCAD SHX Text N
AutoCAD SHX Text
TAX LOT 7500 (HOUSE # 1621)
AutoCAD SHX Text
TAX LOT 6300 (HOUSE # 1620)
AutoCAD SHX Text
TAX LOT 9100 (HOUSE # 1479)
AutoCAD SHX Text 0+00
AutoCAD SHX Text 672'
AutoCAD SHX Text 670'
AutoCAD SHX Text 668'
AutoCAD SHX Text 666'
AutoCAD SHX Text 664'
AutoCAD SHX Text 662'
AutoCAD SHX Text 674'
AutoCAD SHX Text 676'
AutoCAD SHX Text 678'
AutoCAD SHX Text 680'
AutoCAD SHX Text 682'
AutoCAD SHX Text 684'
AutoCAD SHX Text 686'
AutoCAD SHX Text 688'
AutoCAD SHX Text 690'
AutoCAD SHX Text 692'
AutoCAD SHX Text 660'
AutoCAD SHX Text 672'
AutoCAD SHX Text 670'
AutoCAD SHX Text 674'
AutoCAD SHX Text 676'
AutoCAD SHX Text 678'
AutoCAD SHX Text 680'
AutoCAD SHX Text 682'
AutoCAD SHX Text 684'
AutoCAD SHX Text 686'
AutoCAD SHX Text 688'
AutoCAD SHX Text 690'
AutoCAD SHX Text 692'
AutoCAD SHX Text
TAX LOT 9200 (HOUSE # 1469)
AutoCAD SHX Text
TAX LOT 9300 (HOUSE # 1459)
AutoCAD SHX Text
TAX LOT 7600 (HOUSE # 1529)
AutoCAD SHX Text
TAX LOT 6200 (HOUSE # 1490)
AutoCAD SHX Text
TAX LOT 6100 (HOUSE # 1470)
AutoCAD SHX Text STA. 0+63.32 (-14.6') 0+63.32 (-14.6') NEW CURB INLET CATCH BASIN PER DETAIL RIM/TFOC=678.99' NEW 4" PVC DRAIN (E) IEI=677.01'NEW 12" CPP (S) IEO=675.40'12" SUMP=673.90'
AutoCAD SHX Text
EX GRADE @ EX. ROAD CENTERLINE
AutoCAD SHX Text STA. 0+04.98 (-0.2') EX. SD MH RIM=674.69' EX. 24" CONC. (E) IEI=668.81'EX. 24" ALUM. SPIRAL (W) IEO=663.72'
AutoCAD SHX Text
EX. 24" ALUM. SPIRAL SD, LF=171.5', S=5.87% SD, LF=171.5', S=5.87%
AutoCAD SHX Text
EX. 24" CPP SD, LF=43.0', S=9.96%
AutoCAD SHX Text STA. 2+27.45 (-0.5') EX. SD MH RIM=690.61' EX. 24" CONC. (E) IEI=685.37'EX. 24" CONC. (W) IEO=684.95'
AutoCAD SHX Text STA. 1+80.49 (0.2') EX. SD MH RIM=686.23' EX. 6" CONC. (SW) IEI=682.87'EX. 6" CONC. (NE) IEI=681.01'EX. 6" CONC. (SE) IEI=680.50'NEW 12" CPP (S) IEI=679.53'EX. 24" CPP (E) IEI=680.67'EX. 24" ALUM. SPIRAL (W) IEO=678.88'
AutoCAD SHX Text STA. 0+63.32 (0.0') NEW 12" SD TEE FROM NEW CURBINLET @ STA. 0+63.32 (-14.6') IE=672.6'±
AutoCAD SHX Text
STA. 1+26.47 EX. WATER SERVICE
AutoCAD SHX Text
STA. 1+09.36 (0.0') EX. GAS LINE CROSSING, CONTRACTOR TO VERIFY
AutoCAD SHX Text
1 SD2
AutoCAD SHX Text
NEW 4" PERF. PVC DRAIN PER DETAILLF=94.5', S=5.53%
AutoCAD SHX Text
STA. 0+63.32 (0.0') NEW 12" SD TEE @ EX. 24" SD,IE=672.62'
AutoCAD SHX Text
NEW 12" CPP SD, LF=12.8',S=21.7%
AutoCAD SHX Text
EXISTING AC REPAIR & NEW CURB/GUTTER PER SHEET C4
AutoCAD SHX Text
EX. PROPERTY LINE / R-O-W (TYP.)
AutoCAD SHX Text 1+00
AutoCAD SHX Text
EXISTING DRIVEWAY (TYP.)
AutoCAD SHX Text 668'
AutoCAD SHX Text
4 SD1
AutoCAD SHX Text 2+00
AutoCAD SHX Text STA. 0+63.32 (-14.6') NEW CURB INLET CATCH BASIN RIM/TFOC=678.99' NEW 4" PVC DRAIN (E) IEI=677.01'NEW 12" CPP (S) IEO=675.40'18" SUMP=673.90'
AutoCAD SHX Text
NEW 4" PERF. DRAINIE=682.32'
AutoCAD SHX Text
EX. 24" CONC. SD
AutoCAD SHX Text
EX. 24" CONC. SD
AutoCAD SHX Text
NEW 4" PERF. PVC DRAIN, LF=96.0', S=5.53%
AutoCAD SHX Text
STA. 1+58.48 (-15.3') EX. WATERMAIN CROSSING @ NEW CURB AND GUTTER
AutoCAD SHX Text
NEW TFOC
AutoCAD SHX Text
PROVIDE & INSTALL A MANUFACTURER'S PLUG/CAP AT END OF NEW 4" PERF.PVC DRAIN PIPE
AutoCAD SHX Text
NEW 4" PVC DRAIN LF=1.5', S=5.53%
AutoCAD SHX Text GENERAL NOTES: : 1. ALL NEW CURB INLET CATCH BASINS ARE TO BE ALL NEW CURB INLET CATCH BASINS ARE TO BE FITTED WITH A WATER QUALITY FILTER SYSTEM SUCH AS FLOGARD, FLEXSTORM OR APPROVED EQUAL. 2. FINISH GRADE SURFACE CONTOURS SHOWN.FINISH GRADE SURFACE CONTOURS SHOWN.
AutoCAD SHX Text
JWN
AutoCAD SHX Text
JWN
AutoCAD SHX Text
CITY REVIEW COMMENTS
AutoCAD SHX Text
CONTRACTORS NOTIFICATION REQUIREMENTS LAW
ATTENTION: OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED BY THE OREGON UTILITY NOTIFICATION CENTER.
THOSE RULES ARE SET FORTH IN OAR-952-001-0090. YOU MAY OBTAIN COPIES OF THE RULES BY CALLING THE CENTER.
0' 10' 20'
PLAN SCALE
C3
1PLAN VIEW - STA. 1+00 TO STA. 4+00
LINE IS 1 INCH
AT FULL SCALE
DESIGNED: DRAWN: REVISIONS
IF NOT 1-INCH - SCALE ACCORDINGLY
DRAWING NO.
SHEET NO.DATE
PROJECT NO.
APPROVED BY:
DATE: N.E. WINTER ST. - STREET IMPROVEMENT PLAN/E
XE
IP R S 21
62/31
80160PE
OREGON
E
E
GN
I N
E
R
REG
ISTERED PROFESS IONA L
JAMES W . NORR I NGTO
NJ UNE 0 2 , 2 0 1 0
11OF
JWN 26.18
NOV/2026
C3
NJC
STA. 1+00 TO STA. 4+00
N .E
. B R
O O
K
LY
N A
V E.
N.E. WINTER ST.
C3
2NEW AC STREET OVERLAY DETAIL
WINTER STREET STORM IMPROVEMENTS
CITY OF ROSEBURG PUBLIC WORKS DEPARTMENT
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text
SS
AutoCAD SHX Text
CO
AutoCAD SHX Text
MB
AutoCAD SHX Text
MB
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
NEW AC OVERLAY PER SECTION
AutoCAD SHX Text
SCALE: 1" = 20'
AutoCAD SHX Text N
AutoCAD SHX Text
APPR'D.
AutoCAD SHX Text
SUBMIT.
AutoCAD SHX Text
REVISED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text C:\Users\ncata\Civil Solutions Engineering\Communication Site - Documents\Active Projects\2026 Projects\26.18 Winter St. SD Improvements\Design\DWG\WINTER ST.& STORM_LAYOUTS_5-14-26.dwg, 11/20/2026 10:22:56 AM , 11/20/2026 10:22:56 AM 11/20/2026 10:22:56 AM
AutoCAD SHX Text CIVIL SOLUTIONS ENGINEERING, LLC 445 S. CALAPOOIA ST. SUTHERLIN, OREGON 97479 TELEPHONE: (541) 529-2002 JAMES@CSELLC.NET
AutoCAD SHX Text
KEYED NOTES::
AutoCAD SHX Text
TAX LOT 7600 (HOUSE # 1529)
AutoCAD SHX Text
TAX LOT 7700 (HOUSE # 1571)
AutoCAD SHX Text
TAX LOT 7800 (HOUSE # 1561)
AutoCAD SHX Text
TAX LOT 7900 (HOUSE # 1551)
AutoCAD SHX Text
TAX LOT 9100 (HOUSE # 1479)
AutoCAD SHX Text
TAX LOT 9000 (HOUSE # 1560)
AutoCAD SHX Text
TAX LOT 8900 (HOUSE # 1550)
AutoCAD SHX Text
EX. PROPERTY LINE / R-O-W (TYP.)
AutoCAD SHX Text
STA. 1+30.24 TAPER NEW AC OVERLAY LONGITUDINALLY PER DETAIL
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
EXISTING AC PAVEMENT
AutoCAD SHX Text
EX. GROUND VARIES (TYP.)
AutoCAD SHX Text
EX. CURB & GUTTER (TYP.)
AutoCAD SHX Text
VARIES
AutoCAD SHX Text L
AutoCAD SHX Text C
AutoCAD SHX Text
VARIES
AutoCAD SHX Text 1 M1
AutoCAD SHX Text
EXISTING AC PAVEMENT GRINDING LIMITS PER DETAIL (APPROX. AREA=390 SF)
AutoCAD SHX Text
STA. 3+75.00 TAPER NEW AC OVERLAY LONGITUDINALLY PER DETAIL
AutoCAD SHX Text
EXISTING DRIVEWAY (TYP.)
AutoCAD SHX Text 2 C3
AutoCAD SHX Text
EX. AC PAVEMENT GRINDING LIMITS PER DETAIL (APPROX. AREA=208 SF)
AutoCAD SHX Text 2 C3
AutoCAD SHX Text
VARIES (13'-0"± TO 21-0"±)
AutoCAD SHX Text 13'-0"±
AutoCAD SHX Text 1 M1
AutoCAD SHX Text 1 M1
AutoCAD SHX Text 1 M1
AutoCAD SHX Text 1 M1
AutoCAD SHX Text 1 M1
AutoCAD SHX Text GENERAL NOTES: : 1. WITHIN EXISTING AC PAVEMENT GRINDING LIMITS, IT MAY BE NECESSARY TO REMOVE EXISTING AC WITHIN EXISTING AC PAVEMENT GRINDING LIMITS, IT MAY BE NECESSARY TO REMOVE EXISTING AC PAVEMENT TO FULL DEPTH ADJACENT TO EXISTING CURB & GUTTER RADII. 2. FINISH GRADE SURFACE CONTOURS SHOWN. FINISH GRADE SURFACE CONTOURS SHOWN. 3. ASPHALT CONCRETE (AC) TRENCH PATCHING SHALL BE COMPLETED AT THE END OF EACH WORK WEEK, ASPHALT CONCRETE (AC) TRENCH PATCHING SHALL BE COMPLETED AT THE END OF EACH WORK WEEK, OR SOONER IF 1 INCH OR MORE OF PRECIPITATION IS FORECAST WITHIN ANY 24-HOUR PERIOD.
AutoCAD SHX Text
NEW SD AC TRENCH PATCH PER DETAIL
AutoCAD SHX Text
1 SD1
AutoCAD SHX Text
ADJUST EXISTING VALVE CAN TO NEW FINISH GRADE
AutoCAD SHX Text
JWN
AutoCAD SHX Text
JWN
AutoCAD SHX Text
CITY REVIEW COMMENTS
AutoCAD SHX Text
DESIGNED: DRAWN: REVISIONS
IF NOT 1-INCH - SCALE ACCORDINGLY
DRAWING NO.
SHEET NO.DATE
PROJECT NO.
APPROVED BY:
DATE: N.E. BROOKLYN AVE. - STREET IMPROVEMENT PLAN/E
XE
IP R S 21
62/31
80160PE
OREGON
E
E
GN
I N
E
R
REG
I STERED PROFESS IONA L
JAMES W . NORR I NGTO
NJ UNE 0 2 , 2 0 10
11OF
JWN 26.18
NOV/2026
C4
NJC
STA. 0+36 TO STA. 1+85
CONTRACTORS NOTIFICATION REQUIREMENTS LAW
ATTENTION: OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED BY THE OREGON UTILITY NOTIFICATION CENTER.
THOSE RULES ARE SET FORTH IN OAR-952-001-0090. YOU MAY OBTAIN COPIES OF THE RULES BY CALLING THE CENTER.
0' 5' 10'
PLAN SCALE
C4
1PLAN VIEW - STA. 0+36 TO STA. 1+85
N.E. BROOKLYN AVE.
N .E
. W
IN
TE
R
S T.
C4
2BROOKLYN AVE. PARTIAL RECONSTRUCTION SECTION
WINTER STREET STORM IMPROVEMENTS
CITY OF ROSEBURG PUBLIC WORKS DEPARTMENT
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text
SS
AutoCAD SHX Text
MB
AutoCAD SHX Text
MB
AutoCAD SHX Text
SD
AutoCAD SHX Text
MB
AutoCAD SHX Text REMOVE AND DISPOSE OF EXISTING AC WITHIN SAWCUT LIMITS SHOWN ON PLAN. PROVIDE (2) 2" LIFTS OF AC PAVEMENT PER SPECIFICATIONS
AutoCAD SHX Text
APPR'D.
AutoCAD SHX Text
SUBMIT.
AutoCAD SHX Text
REVISED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text C:\Users\ncata\Civil Solutions Engineering\Communication Site - Documents\Active Projects\2026 Projects\26.18 Winter St. SD Improvements\Design\DWG\WINTER ST.& STORM_LAYOUTS_5-14-26.dwg, 11/20/2026 10:22:56 AM , 11/20/2026 10:22:56 AM 11/20/2026 10:22:56 AM
AutoCAD SHX Text CIVIL SOLUTIONS ENGINEERING, LLC 445 S. CALAPOOIA ST. SUTHERLIN, OREGON 97479 TELEPHONE: (541) 529-2002 JAMES@CSELLC.NET
AutoCAD SHX Text
TAX LOT 6300 (HOUSE # 1620)
AutoCAD SHX Text
TAX LOT 9100 (HOUSE # 1479)
AutoCAD SHX Text
TAX LOT 9200 (HOUSE # 1469)
AutoCAD SHX Text
TAX LOT 6200 (HOUSE # 1490)
AutoCAD SHX Text
KEYED NOTES::
AutoCAD SHX Text
NEW CURB & GUTTER PER DETAIL (LF=13.3' S=3.8%)
AutoCAD SHX Text 2 M1
AutoCAD SHX Text
SCALE: 1" = 10'
AutoCAD SHX Text N
AutoCAD SHX Text
NEW CURB & GUTTER PER DETAIL (LF=88.3' S=5.6%)
AutoCAD SHX Text
NEW CURB & GUTTER PER DETAIL (LF=13.6' S=9.7%)
AutoCAD SHX Text R20'-6"
AutoCAD SHX Text S=7.5%
AutoCAD SHX Text
EX. AC SAWCUT LIMITS (TOTAL LF=153'±)
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
NEW AC PAVEMENT PER SECTION (TOTAL AREA=1,364± SF)
AutoCAD SHX Text 2 C4
AutoCAD SHX Text
13'-0" TYP.
AutoCAD SHX Text
EX. PROPERTY LINE / R-O-W (TYP.)
AutoCAD SHX Text S=5.7%
AutoCAD SHX Text S=5.3%
AutoCAD SHX Text S=4.6%
AutoCAD SHX Text S=4.6%
AutoCAD SHX Text S=7.3%
AutoCAD SHX Text
EXISTING DRIVEWAY (TYP.)
AutoCAD SHX Text EXISTING MAILBOX (3x) TO BE REMOVED AND TEMPORARILY REINSTALLED PRIOR TO CONSTRUCTION ACTIVITIES AND THEN REINSTALLED PERMANENTLY PER DETAIL
AutoCAD SHX Text
LIMITS OF EXISTING ROAD BASE & SUBGRADE REMOVAL PER SECTION
AutoCAD SHX Text 2 C4
AutoCAD SHX Text
NEW SEPARATION GEOTEXTILE FABRIC
AutoCAD SHX Text PLACE & COMPACT NEW 1" MINUS AGGREGATE BASE TO 95% OF T99 (STANDARD PROCTOR), MAX. 8" LIFT
AutoCAD SHX Text PROVIDE FOUNDATION STABILIZATION AS DIRECTED BY ENGINEER UTILIZING 3" MINUS AGGREGATE OVER GEOTEXTILE FABRIC
AutoCAD SHX Text
EXISTING FINISH GRADE (VARIES)
AutoCAD SHX Text
FINISH GRADE NATIVE BACKFILL
AutoCAD SHX Text
NEW SUBSURFACE DRAIN PER DETAIL
AutoCAD SHX Text
4 SD1
AutoCAD SHX Text
NEW CURB & GUTTER PER DETAIL
AutoCAD SHX Text 2 M1
AutoCAD SHX Text
EXISTING ROAD BASE (TYP.), RECOMPACT PRIOR TO PLACEMENT OF NEW AC PAVEMENT
AutoCAD SHX Text
EXISTING AC PAVEMENT
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text 2 C4
AutoCAD SHX Text
SAWCUT PER PLAN
AutoCAD SHX Text 2 M1
AutoCAD SHX Text 2 M1
AutoCAD SHX Text 1 M2
AutoCAD SHX Text 6"
AutoCAD SHX Text GENERAL NOTES: : 1. FINISH GRADE SURFACE CONTOURS SHOWN. FINISH GRADE SURFACE CONTOURS SHOWN. 2. PROVIDE 3-INCH WEEP HOLES IN NEW CURB PER SPECIFICATIONS.PROVIDE 3-INCH WEEP HOLES IN NEW CURB PER SPECIFICATIONS.
AutoCAD SHX Text
NEW SEPARATION GEOTEXTILE FABRIC
AutoCAD SHX Text
JWN
AutoCAD SHX Text
JWN
AutoCAD SHX Text
CITY REVIEW COMMENTS
AutoCAD SHX Text
DESIGNED: DRAWN: REVISIONS
IF NOT 1-INCH - SCALE ACCORDINGLY
DRAWING NO.
SHEET NO.DATE
PROJECT NO.
APPROVED BY:
DATE: STORM DRAIN STANDARD DETAILS/E
XE
IP R S 21
62/31
80160PE
OREGON
E
E
GN
I N
E
R
REG
I STERED PROFESS IONAL
JAMES W . NORR I NGTO
NJ UNE 0 2 , 2 0 10
11OF
JWN 26.18
NOV/2026
SD1
NJC
SD1
2STANDARD MANHOLE DETAIL
SD1
3TYPICAL MANHOLE FRAME AND COVER
(APPROX. WT. - 305 LBS.)
CAST IRON SUBURBAN FRAMECOVER
30 3/4"
24 1/2"
3"
6"
23" 25" 27"
1/ 2"
2"
22" 7/ 8"
24 3/4"
GRATED LID
B B
1-1/2" OPENINGS
1"
"B"
MIN
"B"
MIN
"A"
NOM. PIPE
DIAMETER
TRENCH BACKFILL
CLASS AS SHOWN
ON THE PLANS OR
SPECIFIED
SD1
1TYPICAL TRENCH SECTION
SD1
4SUBSURFACE DRAIN @ NEW CURB
WINTER STREET STORM IMPROVEMENTS
CITY OF ROSEBURG PUBLIC WORKS DEPARTMENT
AutoCAD SHX Text
APPR'D.
AutoCAD SHX Text
SUBMIT.
AutoCAD SHX Text
REVISED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text C:\Users\ncata\Civil Solutions Engineering\Communication Site - Documents\Active Projects\2026 Projects\26.18 Winter St. SD Improvements\Design\DWG\WINTER ST.& STORM_LAYOUTS_5-14-26.dwg, 11/20/2026 10:22:56 AM , 11/20/2026 10:22:56 AM 11/20/2026 10:22:56 AM
AutoCAD SHX Text CIVIL SOLUTIONS ENGINEERING, LLC 445 S. CALAPOOIA ST. SUTHERLIN, OREGON 97479 TELEPHONE: (541) 529-2002 JAMES@CSELLC.NET
AutoCAD SHX Text 36"
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
4" MIN.
AutoCAD SHX Text
6" MIN.
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text 48"
AutoCAD SHX Text
6'-0" MIN.
AutoCAD SHX Text DETAIL NOTE: : 1. PROVIDE SLOTTED COVER WHERE INDICATED ON PLANS PROVIDE SLOTTED COVER WHERE INDICATED ON PLANS 2. ALL MANHOLES LESS THAN 6' IN DEPTH SHALL BE FLAT MANHOLESALL MANHOLES LESS THAN 6' IN DEPTH SHALL BE FLAT MANHOLES
AutoCAD SHX Text
RIM SET TO FINISH GRADE (SEE PROFILES)
AutoCAD SHX Text
PRECAST RISER RINGS, PROVIDE A MIN. OF (4) FOR FUTURE RIM ADJUSTABILITY
AutoCAD SHX Text
HOLE FOR TONING WIRE PER NOTE NO. 11 BELOW
AutoCAD SHX Text
COATED STEEL STEPS
AutoCAD SHX Text
PRECAST OFFSET CONE
AutoCAD SHX Text
PREFORMED GASKET AT SECTION JOINTS
AutoCAD SHX Text
PRECAST BARREL SECTION
AutoCAD SHX Text
CONTOUR CONCRETE TO PROVIDE SMOOTH CHANNEL
AutoCAD SHX Text
3300 PSI CONCRETE
AutoCAD SHX Text
AGGREGATE BASE (6" MIN.)
AutoCAD SHX Text
CAST IRON FRAME AND COVER, SEE
AutoCAD SHX Text
3 SD1
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text NOTE: : 1. PROVIDE GRATED COVERS OVER STORM DRAIN MANHOLES WHERE SHOWN ON PLANSPROVIDE GRATED COVERS OVER STORM DRAIN MANHOLES WHERE SHOWN ON PLANS
AutoCAD SHX Text
6" MIN.
AutoCAD SHX Text
6" MIN.
AutoCAD SHX Text
FINAL SAWCUT SEE NOTE 1
AutoCAD SHX Text
FINAL SAWCUT SEE NOTE 1
AutoCAD SHX Text
COMPACTED BACKFILL
AutoCAD SHX Text
TABLE A
AutoCAD SHX Text "A" (in)
AutoCAD SHX Text "B" (in)
AutoCAD SHX Text "C" (in)
AutoCAD SHX Text "D" (in)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
"D" MIN ABOVE OUTSIDE OF PIPE BELL
AutoCAD SHX Text
TONING WIRE (FORCEMAINS & WATERLINES)
AutoCAD SHX Text
NEW PIPE
AutoCAD SHX Text
"C" MIN BEDDING BELOW OUTSIDE OF PIPE BELL
AutoCAD SHX Text AT EXISTING GRAVEL ROADS CLASS "B" BACKFILL IS TO BE LEVEL WITH FINISHED GRADE OF THE EXISTING ROAD SURFACE.
AutoCAD SHX Text
PROVIDE (1) 2" LIFT OF AC PER SPECIFICATIONS
AutoCAD SHX Text
TRENCH LIMITS
AutoCAD SHX Text
FOUNDATION STABILIZATION AS REQUIRED BY ENGINEER
AutoCAD SHX Text NOTES: : 1. TRENCH LINES LOCATED IN YARD TRENCH LINES LOCATED IN YARD AREAS SHALL BE CAPPED WITH A MINIMUM OF 4" OF TOP SOIL AND SEEDED PER THE SPECIFICATIONS. 2. IN AREAS OUTSIDE THE ROADWAY, IN AREAS OUTSIDE THE ROADWAY, PROVIDE TOP SOIL (8") DEPTH OR AS REQUIRED WITH GRASS SEED SPECIFIED TO MATCH EXISTING GROUND
AutoCAD SHX Text
PIPE ZONE
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
NEW DRAINAGE GEOTEXTILE FABRIC WITH 12" MIN. OVERLAP
AutoCAD SHX Text
NEW 1" WASHED, OPEN GRADED DRAIN ROCK
AutoCAD SHX Text
NEW AGGREGATE BASE PER SECTION
AutoCAD SHX Text
NEW 4" PERFORATED D3034 SDR35 PVC DRAIN PIPE ENVELOPED W/ DRAIN ROCK
AutoCAD SHX Text
WIDTH PER TABLE A
AutoCAD SHX Text
NEW CURB & GUTTER PER DETAIL
AutoCAD SHX Text 2 M1
AutoCAD SHX Text
NEW AC PAVEMENT PER SECTION
AutoCAD SHX Text 2 C4
AutoCAD SHX Text 2 C4
AutoCAD SHX Text
VARIES
AutoCAD SHX Text 12"
AutoCAD SHX Text
JWN
AutoCAD SHX Text
JWN
AutoCAD SHX Text
CITY REVIEW COMMENTS
AutoCAD SHX Text
DESIGNED: DRAWN: REVISIONS
IF NOT 1-INCH - SCALE ACCORDINGLY
DRAWING NO.
SHEET NO.DATE
PROJECT NO.
APPROVED BY:
DATE: STORM DRAIN STANDARD DETAILS (CONTINUED)/E
XE
IP R S 21
62/31
80160PE
OREGON
E
E
GN
I N
E
R
REG
I STERED PROFESS IONAL
JAMES W . NORR I NGTO
NJ UNE 0 2 , 2 0 10
11OF
JWN 26.18
NOV/2026
SD2
NJC
SD2
1CURB INLET DETAIL
WINTER STREET STORM IMPROVEMENTS
CITY OF ROSEBURG PUBLIC WORKS DEPARTMENT
AutoCAD SHX Text
APPR'D.
AutoCAD SHX Text
SUBMIT.
AutoCAD SHX Text
REVISED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text C:\Users\ncata\Civil Solutions Engineering\Communication Site - Documents\Active Projects\2026 Projects\26.18 Winter St. SD Improvements\Design\DWG\WINTER ST.& STORM_LAYOUTS_5-14-26.dwg, 11/20/2026 10:22:56 AM , 11/20/2026 10:22:56 AM 11/20/2026 10:22:56 AM
AutoCAD SHX Text CIVIL SOLUTIONS ENGINEERING, LLC 445 S. CALAPOOIA ST. SUTHERLIN, OREGON 97479 TELEPHONE: (541) 529-2002 JAMES@CSELLC.NET
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text 2'-9"
AutoCAD SHX Text
TOP FACE OF CURB
AutoCAD SHX Text 16-1/2"
AutoCAD SHX Text 1/2"x10" ANCHOR BOLT, NUT(2)
AutoCAD SHX Text
FIBERGLASS LINER (OPT.)
AutoCAD SHX Text 17-1/8"
AutoCAD SHX Text
SL. 2%
AutoCAD SHX Text
TOP SECTION
AutoCAD SHX Text 2' 0"
AutoCAD SHX Text 3' 0"
AutoCAD SHX Text 17"
AutoCAD SHX Text
VARIABLE
AutoCAD SHX Text
TOP CURB GRADE
AutoCAD SHX Text
SUBGRADE
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
BASE SECTION
AutoCAD SHX Text
BASE MAY BE PRE-CAST OR CAST IN PLACE
AutoCAD SHX Text
SECTION A - A
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text 3'-6"
AutoCAD SHX Text 2'-9"
AutoCAD SHX Text 2'-6"
AutoCAD SHX Text
PLAN
AutoCAD SHX Text 1/2"x10" ANCHOR BOLT, NUT(2)
AutoCAD SHX Text ANGLE NOSING 3-1/2"x3-1/2"x1/4"
AutoCAD SHX Text
6" RAD. NOSING AT TOP
AutoCAD SHX Text
FIBER GLASS LINER (OPT.)
AutoCAD SHX Text
BACK OF CURB
AutoCAD SHX Text
TOP FACE OF CURB
AutoCAD SHX Text
BOTTOM FACE OF CURB
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text
TOP OF CURB
AutoCAD SHX Text
NORMAL GUTTER
AutoCAD SHX Text
FLOW LINE
AutoCAD SHX Text 2'-6"
AutoCAD SHX Text
FIBER GLASS LINER (OPT.)
AutoCAD SHX Text 16-1/2"
AutoCAD SHX Text
PERSPECTIVE VIEW
AutoCAD SHX Text 1' 4-1/2"
AutoCAD SHX Text 2'-6"
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text 3'-6"
AutoCAD SHX Text 4"x4" - 6"x6" WIRE MESH REINFORCING
AutoCAD SHX Text 3-1/2"x3-1/2"x1/4" ANGLE NOSING
AutoCAD SHX Text
FIBERGLASS LINER (OPT.)
AutoCAD SHX Text
24" CAST IRON MANHOLE COVER
AutoCAD SHX Text
MANHOLE GRADE ADJUSTMENT RING
AutoCAD SHX Text
TOP OF CURB
AutoCAD SHX Text
GUTTER FLOW LINE
AutoCAD SHX Text
DETAIL SECTION B-B
AutoCAD SHX Text
#10 GA. 2" LID RING
AutoCAD SHX Text
#10 GA. 2" COVER FRAME
AutoCAD SHX Text
FIBERGLASS LINER (OPT.)
AutoCAD SHX Text
NORMAL GUTTER
AutoCAD SHX Text
2" DROP
AutoCAD SHX Text
TOP OF CURB
AutoCAD SHX Text ANGLE NOSING 3-1/2"x3-1/2"x1/4"
AutoCAD SHX Text
COVER RECESS 27-1/16" I.D.
AutoCAD SHX Text
PRE-CAST ACCESS 26-3/4" O.D.
AutoCAD SHX Text 6" R.
AutoCAD SHX Text
24" I.D. OPENING
AutoCAD SHX Text B
AutoCAD SHX Text
NOTE: FOR BASE SECTION AND PLAN VIEW SEE ALTERNATE SECTION LEFT.
AutoCAD SHX Text
GUTTER FLOW LINE
AutoCAD SHX Text
TOP FACE OF CURB
AutoCAD SHX Text
CURB
AutoCAD SHX Text 2'-0"
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text 3'-6"
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text
LIMITS OF GUTTER
AutoCAD SHX Text
PAY LIMIT CURB & GUTTER
AutoCAD SHX Text NOTE: : 1. CONCRETE SHALL ATTAIN A STRENGTH OF 3300 PSI IN 20 DAYS. CONCRETE SHALL ATTAIN A STRENGTH OF 3300 PSI IN 20 DAYS. 2. TOP SHALL BE REINFORCED WITH 4"x4"-6"x6" WIRE MESH. TOP SHALL BE REINFORCED WITH 4"x4"-6"x6" WIRE MESH. 3. ALL METAL PARTS SHALL BE HOT DIPPED GALV. AFTER FABRICATION ALL METAL PARTS SHALL BE HOT DIPPED GALV. AFTER FABRICATION 4. ALL CURB INLET CATCH BASINS TO BE FITTED WITH WATER QUALITY FILTER ALL CURB INLET CATCH BASINS TO BE FITTED WITH WATER QUALITY FILTER INSERTS SUCH AS FLOGARD, FLEXSTORM, OR APPROVED EQUAL.
AutoCAD SHX Text
PAY LIMIT CURB & GUTTER
AutoCAD SHX Text
JWN
AutoCAD SHX Text
JWN
AutoCAD SHX Text
CITY REVIEW COMMENTS
AutoCAD SHX Text
DESIGNED: DRAWN: REVISIONS
IF NOT 1-INCH - SCALE ACCORDINGLY
DRAWING NO.
SHEET NO.DATE
PROJECT NO.
APPROVED BY:
DATE: MISCELLANEOUS DETAILS/E
XE
IP R S 21
62/31
80160PE
OREGON
E
E
GN
I N
E
R
REG
I STERED PROFESS IONAL
JAMES W . NORR I NGTO
NJ UNE 0 2 , 2 0 10
11OF
JWN 26.18
NOV/2026
M1
NJC
M1
1AC OVERLAY DETAIL - RD610
M1
2STANDARD CURB AND GUTTER
M1
3TYPICAL SIGN INSTALLATION
WINTER STREET STORM IMPROVEMENTS
CITY OF ROSEBURG PUBLIC WORKS DEPARTMENT
AutoCAD SHX Text
APPR'D.
AutoCAD SHX Text
SUBMIT.
AutoCAD SHX Text
REVISED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text C:\Users\ncata\Civil Solutions Engineering\Communication Site - Documents\Active Projects\2026 Projects\26.18 Winter St. SD Improvements\Design\DWG\WINTER ST.& STORM_LAYOUTS_5-14-26.dwg, 11/20/2026 10:22:56 AM , 11/20/2026 10:22:56 AM 11/20/2026 10:22:56 AM
AutoCAD SHX Text CIVIL SOLUTIONS ENGINEERING, LLC 445 S. CALAPOOIA ST. SUTHERLIN, OREGON 97479 TELEPHONE: (541) 529-2002 JAMES@CSELLC.NET
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
8'-0" COLD PLANE PVMT. REMOVAL
AutoCAD SHX Text 5'
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
NEW AC PAVEMENT
AutoCAD SHX Text 18"
AutoCAD SHX Text R = 2"
AutoCAD SHX Text
AGGREGATE BASE
AutoCAD SHX Text 13"
AutoCAD SHX Text 4"
AutoCAD SHX Text S = 5%
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
36" ANCHOR POST
AutoCAD SHX Text
BEHIND CURB INSTALLATION
AutoCAD SHX Text
STOP
AutoCAD SHX Text
STREET NAME
AutoCAD SHX Text E
AutoCAD SHX Text
ST
AutoCAD SHX Text
MIN. 7'-0" CLEAR
AutoCAD SHX Text
CAP NEW POST AS REQUIRED
AutoCAD SHX Text
2" ROUND GALVANIZED POST 12FT
AutoCAD SHX Text
CONNECT W/ SST 3/8" DRIVE CORNER BOLT & NUT MIN. TWO BOLTS PER SIGN CONNECTION
AutoCAD SHX Text
EXISTING GROUND
AutoCAD SHX Text SIGN DETAIL NOTE: : 1. THE EXISTING SIGN POST IS TO BE THE EXISTING SIGN POST IS TO BE REUSED WITH PRIOR CITY APPROVAL. 2. IF THE SIGN POST DAMAGED BY THE IF THE SIGN POST DAMAGED BY THE CONTRACTORS ACTIONS, THE SIGN POST SHALL BE REPLACED PER THIS DETAIL AND THE SPECIFICATIONS.
AutoCAD SHX Text
JWN
AutoCAD SHX Text
JWN
AutoCAD SHX Text
CITY REVIEW COMMENTS
AutoCAD SHX Text
DESIGNED: DRAWN: REVISIONS
IF NOT 1-INCH - SCALE ACCORDINGLY
DRAWING NO.
SHEET NO.DATE
PROJECT NO.
APPROVED BY:
DATE: MISCELLANEOUS DETAILS CONTINUED/E
XE
IP R S 21
62/31
80160PE
OREGON
E
E
GN
I N
E
R
REG
I STERED PROFESS IONAL
JAMES W . NORR I NGTO
NJ UNE 0 2 , 2 0 10
11OF
JWN 26.18
NOV/2026
M2
NJC
M2
1MAILBOX INSTALLATION DETAIL - RD101
WINTER STREET STORM IMPROVEMENTS
CITY OF ROSEBURG PUBLIC WORKS DEPARTMENT
AutoCAD SHX Text
APPR'D.
AutoCAD SHX Text
SUBMIT.
AutoCAD SHX Text
REVISED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text C:\Users\ncata\Civil Solutions Engineering\Communication Site - Documents\Active Projects\2026 Projects\26.18 Winter St. SD Improvements\Design\DWG\WINTER ST.& STORM_LAYOUTS_5-14-26.dwg, 11/20/2026 10:22:56 AM , 11/20/2026 10:22:56 AM 11/20/2026 10:22:56 AM
AutoCAD SHX Text CIVIL SOLUTIONS ENGINEERING, LLC 445 S. CALAPOOIA ST. SUTHERLIN, OREGON 97479 TELEPHONE: (541) 529-2002 JAMES@CSELLC.NET
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
JWN
AutoCAD SHX Text
JWN
AutoCAD SHX Text
CITY REVIEW COMMENTS
AutoCAD SHX Text
| Sheets and Views |
| WINTER ST.& STORM_LAYOUTS_5-14-26-G1 |
| WINTER ST.& STORM_LAYOUTS_5-14-26-G2 |
| WINTER ST.& STORM_LAYOUTS_5-14-26-G3 |
| WINTER ST.& STORM_LAYOUTS_5-14-26-C1 |
| WINTER ST.& STORM_LAYOUTS_5-14-26-C2 |
| WINTER ST.& STORM_LAYOUTS_5-14-26-C3 |
| WINTER ST.& STORM_LAYOUTS_5-14-26-C4 |
| WINTER ST.& STORM_LAYOUTS_5-14-26-SD1 |
| WINTER ST.& STORM_LAYOUTS_5-14-26-SD2 |
| WINTER ST.& STORM_LAYOUTS_5-14-26-M1 |
| WINTER ST.& STORM_LAYOUTS_5-14-26-M2 |
File details come from the government source that posted it. Updated .