VA250-17-B-0384-00002002.pdf

PDF 88 KB Posted

Attached to
Construct Surgery Addition Project 757-203 Federal contract opportunity
Solicitation number
VA25017B0384
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10

About this file

VA250-17-B-0384 00002 2018_02-13 Surgery Sole Source Update1.pdf

View the file

Other files for this federal contract opportunity

Other files attached to Construct Surgery Addition Project 757-203, newest first.
File Type Posted
36C25018C0081-003.docx DOCX document
VA250-17-B-0384-00003000.docx DOCX document
VA250-17-B-0384-00003001.pdf PDF
VA250-17-B-0384-00003002.pdf PDF
VA250-17-B-0384-00002001.pdf PDF
VA250-17-B-0384-00002000.docx DOCX document
VA250-17-B-0384-00001000.docx DOCX document
VA250-17-B-0384-00001001.pdf PDF
VA250-17-B-0384-003.pdf PDF
VA250-17-B-0384-001.docx DOCX document
VA250-17-B-0384-009.pdf PDF
VA250-17-B-0384-006.pdf PDF
VA250-17-B-0384-005.pdf PDF
VA250-17-B-0384-004.pdf PDF
VA250-17-B-0384-007.pdf PDF
VA250-17-B-0384-008.pdf PDF
VA250-17-B-0384-002.docx DOCX document
VA250-17-B-0384-000.docx DOCX document
Show all 18

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S:\_AMMS Shared Files\ProDoc\Construct Surgery Addition - Construction\2018_02-13 Surgery Sole Source Update

"Sole Source" Products Listing Project Name: Chalmer's P. Wylie ACC, Construct Surgery Addition VA Project No.: 757-116-12

CBLH Design Proj. No.: 18904.00 Date: 04/28/2017

ITEM NO. ITEM DESCRIPTION

SPEC SECTION /

DRAWING NO. MANUFACTURER/MODEL # SOLE SOURCE JUSTIFICATION ESTIMATED SYSTEM VALUE

1 Access Control E-002 Tyco SOLE Existing Conditions IStar Pro 8 - SH0033-DS-200908 - - Battery Backup Power Supply - SS051_1202 - - Power Supply - DSAL400ULPD8 - - Reader Module - SH0146-DS-200903 - - 5 Port Switch - D-FS105 - - Card Reader - SWH-4100 - -

2 Fire Alarm 283100/E-001 Simplex SOLE Existing Conditions Strobe - 4906-9101 - - Speaker/Strobe - 4906-9151 - - Relay IAM - 4090-9002 - - Monitor Module - 4090-9051 - - Pull Station - 4099-9004 - - Smoke Detector - 4098-9714 - - Remote Test Station - 2098-9806 - - Duct Detector - 4098-9756 - - Transponder Panel - 4100-9600 - -

3 Security Cameras E-002 Axis SOLE Compatibility with existing security management system Interior PTZ camera P5515 - - Mounting Hardware Numerous Part #'s - -

4 Nurse call 275223 Simplex Grinnel SOLE Existing System Master Station - - Wall Station - - Dome Light - - PoE Switch - - Toilet Station - - Graphical Annunciator - -

5 Temperature Controls 230923 Johnson Controls SOLE Existing System

6 Glazed Aluminum Curtainwall Framing 084413 Oldcastle SOLE Existing Façade Integration

7 Insulated Metal Wall Panels 074000 Kingspan SOLE Existing Façade Integration

S:\_AMMS Shared Files\ProDoc\Construct Surgery Addition - Construction\2018_02-13 Surgery Sole Source Update

2 Fire Alarm 283100/E-001 Simplex SOLE Existing Conditions