Pt 06A--Schedule E - Traverse City, MI.pdf

PDF 1 MB Posted

Attached to
TRAVERSE CITY, MI CBOC Clarification #1
Solicitation number
VA10115R0222
Issued by

About this file

VA10115R0222 Attachment

View the file

Other files

File Type Posted
VA101-15-R-0222-015.docx DOCX document
VA101-15-R-0222-011.docx DOCX document
VA101-15-R-0222-012.pdf PDF
Pt 08U--SF-3881 and Instructions - Vendorizing Form.doc DOC document
Pt 08N--Cert of Curr Cost or Pricing Data.doc DOC document
Pt 01--BasicRequirements - Traverse City, MI.PDF PDF
Pt 08I--GSA527 - Oct 2015.pdf PDF
Pt 08F(2)--Modified General Clauses.pdf PDF
Pt 05B--Schedule D - Traverse City, MI.xls XLS spreadsheet
Pt 08B(2) -- Attachment 1 to 1364 - Traverse City.xlsx XLSX spreadsheet
Pt 05A--Schedule D - Traverse City, MI.pdf PDF
Pt 08D--GSA1217 - Nov 2016.pdf PDF
Pt 08G--GSA_Form_3518-SAM_Reps_and_Certs_Addendum.pdf PDF
Pt 09A--Conceptual Plans - Traverse City, MI.pdf PDF
Pt 09B--PDF Drawings.zip ZIP file
Pt 10A--Schedule F -Traverse City, MI.pdf PDF
Pt 03A--Schedule B - Traverse City, MI.pdf PDF
Pt 07--Labor Standards Provision - Traverse City, MI.pdf PDF
Pt 08M--SF 25_Performance Bond - Exp 07-31-19.pdf PDF
Pt 08B(1)--GSA Form 1364A - Dec 2004.doc DOC document
Pt 08F(1)--GSA Form 3517B_06_07_16.pdf PDF
Pt 08P--Seismic Certificates_A - F - Sept 2012.pdf PDF
Pt 08T--FAR Clause 52.209-5 - Oct 2015.pdf PDF
Pt 08L--SF 25A - Payment Bond - Exp 07-31-19.pdf PDF
Pt 02B--Schedule A MCW - Traverse City, MI.docx DOCX document
Pt 08J —
Pt 04A--Schedule C - Traverse City, MI.pdf PDF
Pt 08C--1364A - Guidance.doc DOC document
Pt 08E--GSA3516 - Apr 2015.pdf PDF
Pt 08S--FAR 52.204-10 Reporting Exec Comp Oct 2016.pdf PDF
Pt 08A--Forms Divider.pdf PDF
Pt 08R--VA National Rules of Behavior.pdf PDF
Pt 08H--SF330 - Mar 2013.pdf PDF
Pt 02A--Schedule A - Traverse City, MI.pdf PDF
Pt 06B--Schedule E - Traverse City, MI.xlsx XLSX spreadsheet
Pt 08W--Offering Entity Acknowledgment Page.pdf PDF
Pt 04B-- Schedule C -Traverse City, MI.xls XLS spreadsheet
Pt 09C--CAD Drawings.zip ZIP file
Pt 01--BasicRequirements - Traverse City, MI.DOC DOC document
Pt 08Q--FPLS 12000 - May 2015.pdf PDF
Pt 08O--Cert of Build Energy Performance.doc DOC document
Pt 08K--SF24_Bid Bond - Exp 07-31-19.pdf PDF
Pt 10B--Schedule F -Traverse City, MI.xlsx XLSX spreadsheet
PT 08V--Contractor Confidentiality Cert_PS Design Stds Data Def.pdf PDF
Pt 08J —
VA101-15-R-0222-010.docx DOCX document
VA101-15-R-0222-005.docx DOCX document
VA101-15-R-0222-003.docx DOCX document
VA101-15-R-0222-001.pdf PDF
VA101-15-R-0222-000.docx DOCX document
Show all 50

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COMMUNITY-BASED MAY 2017

SOLICITATION FOR OFFERS OUTPATIENT CLINIC SFO No. VA101-15-R-0222

TRAVERSE CITY, MI

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 1 of 30

Lessor __________ Gov’t. __________ __________ of __________ Pages

PART VI

SCHEDULE E

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 2 of 30

PART VI: SCHEDULE E--ROOM FINISH, DOORS & HARDWARE

SECTION 1 ROOM FINISH, DOOR AND HARDWARE SCHEDULE--GENERAL

1.1 ROOM FINISHES, DOOR AND HARDWARE SCHEDULE

1.1.1 USE OF SCHEDULE E

1.1.2 OTHER REQUIREMENTS

1.2 DOORS

1.2.1 DOORS

1.2.2 DOOR TYPES

1.2.3 DOOR SIZES

1.3 FINISH HARDWARE

1.3.1 GENERAL

1.3.2 BUTT HINGES

1.3.3 CONTINUOUS HINGES

1.3.4 DOOR CLOSING DEVICES

1.3.5 DOOR STOPS

1.3.6 LOCKS AND LATCHES

1.3.7 PUSH-BUTTON COMBINATION LOCKS

1.3.8 ELECTROMAGNETIC LOCKS

1.3.9 CARD READERS

1.3.10 ELECTRIC STRIKES

1.3.11 KEYS

1.3.12 ARMOR PLATES, COMBINATION KICK-MOP PLATES AND DOOR EDGING

1.3.13 EXIT DEVICES

1.3.14 WEATHERSTRIPS (FOR EXTERIOR DOORS)

1.3.15 MISCELLANEOUS HARDWARE

1.3.16 PADLOCKS FOR VARIOUS DOORS, GATES AND HATCHES

1.3.17 Exam Room “Barn Door” Hardware (Basis of Design – Aurora Doors)

1.3.18 HARDWARE SETS

SECTION 2 SCHEDULE E

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 3 of 30

PART VI SCHEDULE E--ROOM FINISH, DOORS & HARDWARE

SECTION 1 ROOM FINISH, DOOR AND HARDWARE SCHEDULE--GENERAL

Schedule E lists each type of space or room required in the outpatient clinic. The following information is listed for each space in the Schedule:

Department, Area and Function

Floor, Wall and Ceiling Finishes

Door Symbol and Hardware Set

If the Lessor believes that there are spaces or conditions not included in this Schedule, the question shall be referred to the Contracting Officer.

Note: Common areas or building service areas that are indicated in Schedule E and are not included in the NUSF leased by VA are specifically excluded from the quantities listed in Schedule C.

1.1 ROOM FINISHES, DOOR AND HARDWARE SCHEDULE

1.1.1 USE OF SCHEDULE E

THE REQUIREMENTS IN THIS SCHEDULE APPLY TO ALL SPACES TO BE

OCCUPIED BY VA IN THE OUTPATIENT CLINIC. LESSOR SHALL PROVIDE

MATERIALS, FINISHES, DOORS, FRAMES, AND HARDWARE IN ACCORDANCE

WITH THIS SCHEDULE AND THE REQUIREMENTS SPECIFIED IN THIS SFO.

Lessor shall provide each space with door(s) of the type and size as listed in Schedule E with hardware as noted. Doors and hardware requirements are indicated by their respective door symbols and hardware set numbers in this Schedule. Additional requirements are defined in Paragraph 1.3, "Doors and Hardware".

The Lessor shall provide room finishes in each room in accordance with Schedule E. Finishes are shown in the schedule for the floor, base, wainscot, wall, and ceiling surfaces for each room or space. The following are abbreviations used for materials and codes throughout the room finishes, door, and hardware schedule. The Lessor shall coordinate abbreviations used in the construction documents prepared by the Lessor with the abbreviations and symbols used in this SFO.

ADO Automatic Door Operator

AF Access Flooring

AT Acoustical Ceiling (Tile)

AT(SP) Acoustical Ceiling (with Sprayed Plastic Finish)

AT(TG) Acoustical Ceiling (with Tegular Edge)

AWF Acoustical Wall Fabric (Tackable)

AWP Acoustical Wall Panel

BP Brick Pavers (Unit Pavers)

BR Brick (Unit Masonry)

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 4 of 30

C Concrete

CMU Concrete Masonry Units (Unit Masonry)

CP Carpet (without Cushion Broadloom)

CPT Carpet Tile

CT Ceramic Tile (Floor, Base, and Wall)

EFTR Existing Finish to Remain

EPY Epoxy (Coatings)

ERF Epoxy Resinous Flooring

EX Existing

EXP Exposed

GL Glass (Glazing)

GWB Gypsum Wallboard Systems

HW Hardware Set (Finish or Builders Hardware)

LM Latex Mastic Flooring

MAT Material

MC Multi-Color Coating

NF Natural Finish

NO Number

P Paint (Exterior, Interior, Transparent Finishes)

PC Precast (Architectural Precast Concrete Panels)

PCP Portland Cement Plaster

PFW Polypropylene Fabric Wallcovering

PL Plaster

PUT Polyurethane

QT Quarry Tile

RAF Resilient Athletic Flooring

RB Resilient Base (Rubber, Vinyl)

RF Raised Rubber Flooring

RSF Resilient Sheet Flooring

SC High Build Glazed Coating (Special Coating)

SP Special Faced

SPEC Special (Architect's Choice)

ST Stone (Cast)

TT Terrazzo Tile (Plastic Matrix)

VCT Resilient Tile Flooring (Vinyl Composition Tile)

VP Veneer Plaster

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 5 of 30

W Wallcovering (Vinyl Coated Fabric)

WB Wall Border

WD Wood

WP Wallcovering Protective (Rigid PVC Sheet)

WSF Welded Seam Sheet Flooring

1.1.2 OTHER REQUIREMENTS

A. Safety Glass There are two (2) types of safety glass that may be required in Interior Spaces; these are:

B. Laminated Fire Glass shall be used in fire rated assemblies Tempered Glass ("T") shall be used in all other Observations Windows and Doors with vision panels, including side lights.

C. Wall Protection at Drinking Fountains and Lavatories Provide vinyl wall covering behind Drinking Fountain Alcoves where wallboard or plaster finish occur and behind lavatories and end walls in examination rooms, treatment rooms, etc. at a minimum 50 inches wide (or terminating at the nearest inside corner). The vinyl wall covering shall go from base to ceiling.

1.2 DOORS

1.2.1 DOORS

The Door Symbol column in Schedule E identifies the type, size and special features of doors for use in a room or space. The number and letters used for the Door Symbol have the following meaning; the first number indicates door type and door material (odd nos. wood and even nos. steel), e.g., "1, 2, 4, etc.". The first letter (or letters) indicate door size e.g. "S, UU, V, etc." The letter after a dash (e.g., "-A") indicates a modification to a door. Use these symbols and designations at door openings on floor plan drawings.

For additional door requirements see Architectural Criteria in Sections 6 and 7 in Part I of the

SFO.

Door Swing: Doors to Housekeeping Aids Closets (HAC) shall open out. HAC doors shall swing out 180o where possible.

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 6 of 30

1.2.2 DOOR TYPES

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 7 of 30

1.2.3 DOOR SIZES

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 8 of 30

1.3 FINISH HARDWARE

1.3.1 GENERAL

A. Hardware Set Numbers on Schedule Except for protective plates, door stops, mutes, thresholds and the like specified herein, hardware requirements for each door are indicated in the Room Finish and Door Schedule by numbers that correspond to the following hardware sets listed in this SFO.

B. Manufacturers' Catalog Number References Where manufacturers' products are specified herein, products of other manufacturers which are considered equivalent to those specified may be used. Manufacturers whose products are specified are identified by abbreviations as follows:

Adams-Rite Adams Rite Mfg. Co. Glendale, CA

Glynn Johnson Glynn Johnson Co. Chicago, IL

LCN LCN Closers Princeton, IL

Firemark Rixon-Firemark Co. Chicago, IL

Hager Hager Hinge Company Saint Louis, MO

Stanley The Stanley Works New Britain, CT

Trimco Triangle Brass Mfg. Co. Los Angeles, CA

Unican Simplex Security Systems Collinsville, CT

Von Duprin Von Duprin Hardware Co. Indianapolis, IN

Zero Zero Weather Stripping Co. New York, NY

C. Keying All cylinders shall be keyed into Grand Master Key System. Provide removable core cylinders that are removable only with a special key or tool without disassembly of knob or lockset Cylinders shall be 7 pin type. Keying information shall be furnished at a later date by the Resident Engineer. Provide lockset cylinders that are compatible with Stanley/Best. The VA is responsible for the cores.

1.3.2 BUTT HINGES

A. ANSI A156.1.

The following types of butt hinges shall be used for the types of doors listed, except where otherwise specified:

(1) Exterior Doors Type A2112 for doors 900 mm (3 feet) wide or less and Type A2111 for doors over 900 mm (3 feet) wide. Hinges for exterior doors shall have non-removable pins.

(2) Interior Doors Type 8112 for doors 900 mm (3 feet) wide or less and Type A8111 for doors over 900 mm (3 feet) wide.

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 9 of 30

(3) Automatic doors hung on butts Type A2111 for exterior doors and aluminum doors, and Type A8111 for other doors.

(4) Labeled Wood Fire Doors Type 8411 or Type 8412; these hinges shall be thru bolted to door with hex nuts and bolts.

1.3.3 CONTINUOUS HINGES

A. ANSI/BHMA A156.26

Grade 1-300.

(1) Listed under Category N in BHMA's "Certified Product Directory."

B. General Minimum 0.120-inch- (3.0-mm-) thick, hinge leaves with minimum overall width of 4 inches (102 mm); fabricated to full height of door and frame and to template screw locations; with components finished after milling and drilling are complete:

(1) Fire Pins Steel pins to hold labeled fire doors in place if required by tested listing.

C. Continuous, Barrel-Type Hinges Hinge with knuckles formed around a pin that extends entire length of hinge.

(1) Base Metal for Exterior Hinges Stainless steel.

(2) Base Metal for Interior Hinges Steel.

(3) Base Metal for Hinges for Fire-Rated Assemblies Stainless steel.

(4) Manufacturers Hager Companies.

Markar Architectural Products, Inc.; a Subsidiary of Adams Rite Manufacturing Co.

McKinney Products Company; an ASSA ABLOY Group company.

Stanley Commercial Hardware; Division. of the Stanley Works and Zero International.

D. Continuous, Gear-Type Hinges Extruded-aluminum, pinless, geared hinge leaves; joined by a continuous extruded-aluminum channel cap; with concealed, self-lubricating thrust bearings.

(1) Manufacturers Bommer Industries, Inc.

Hager Companies.

McKinney Products Company; an ASSA ABLOY Group company.

Pemko Manufacturing Co.

Select Products Limited.

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 10 of 30

Zero International.

1.3.4 DOOR CLOSING DEVICES

Closing devices shall be products of one manufacturer for each type required.

The closer shall have 50 percent adjustable closing force over minimum value for that closer and have adjustable hydraulic back check effective between 60 degrees and 85 degrees of door opening.

Where specified, closer shall have hold-open feature.

Size Requirements: Size closers in accordance with manufacturer’s recommendations or provide multi-size closers, sizes 1 through 6.

1.3.5 DOOR STOPS

A. Conform to ANSI A156.16.

B. Provide door stops wherever an opened door or any item of hardware thereon would strike a wall, column, equipment or other parts of building construction. For concrete, masonry or quarry tile construction, use lead expansion shields for mounting door stops.

C. Where cylindrical locks with turn pieces or pushbuttons occur, equip wall bumpers Type L02251 (rubber pads having concave face) to receive turn piece or button.

D. Substitute floor stops Type L02141 or L02161 as appropriate, when wall bumpers would not provide an effective door stop.

E. Where drywall partitions occur, use floor stops, Type L02141 or L02161.

F. Provide stop Type L02011 or L02181, as applicable for exterior doors.

G. Omit stops where floor mounted door holders are required and where automatic operated doors occur.

H. Provide appropriate roller bumper for each set of doors (except where closet doors occur) where two doors would interfere with each other in swinging.

I. Provide appropriate door mounted stop on doors in individual toilets where floor or wall mounted stops cannot be used.

K. Provide door stops on doors where combination closer magnetic holders are specified.

1.3.6 LOCKS AND LATCHES

A. Conform to ANSI A156.2. Locks and latches for doors 45 mm (1-3/4 inch) thick or over shall have beveled fronts. Lock cylinders shall have not less than seven pins. Cylinders for all locksets shall be removable core type. Cylinders shall be furnished with construction removable cores and construction master keys. Cylinder shall be removable by special key or tool. Construct all cores so that they will be interchangeable into the core housings of all

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 11 of 30 mortise locks, rim locks, cylindrical locks, and any other type lock included in the Great Grand Master Key System. Disassembly of lever or lockset shall not be required to remove core from lockset. All locksets or latches on double doors with fire label shall have latch bolt with 19 mm (3/4 inch) throw. Provide temporary keying device or construction core of allow opening and closing during construction and prior to the installation of final cores.

B. In addition to above requirements, locks and latches shall comply with following requirements:

1. Cylindrical Lock and Latch Sets: levers shall meet ADA (Americans with Disabilities Act) requirements. Cylindrical locksets shall be series 4000 Grade I. Knobs for series 4000 lock and latch sets shall have 57 mm (2-1/4 inch) diameters. Where two turn pieces are specified for lock F76, turn piece on inside knob shall lock and unlock inside knob, and turn piece on outside knob shall unlock outside knob when inside knob is in the locked position. (This function is intended to allow emergency entry into these rooms without an emergency key or any special tool.)

2. Mortise Lock and Latch Sets: Conform to ANSI/BHMA A156.13. Mortise locksets shall be series 1000, minimum Grade 2. All locksets and latchsets shall have lever handles similar to Falcon S-lever Design. Lever handle shall be fabricated from wrought stainless steel. No substitute lever design or material shall be accepted. All locks and latchsets shall be furnished with curved lip strike and wrought box. Furnish armored fronts for all mortise locks.

3. Auxiliary locks shall be as specified under hardware sets and conform to ANSI A156.5.

1.3.7 PUSH-BUTTON COMBINATION LOCKS

A. ANSI/BHMA A156.5, Grade 1. Mechanical or electrically operated as indicated.

B. Construction: Heavy duty cylindrical lock housing conforming to ANSI/BHMA A156.2, Grade 1. Lever handles and operating components in compliance with the UFAS and the ADA Accessibility Guidelines.

C. Special Features: Key override to permit a master keyed security system and a key activated passage feature to allow access without using the entry code.

D. Manufacturers:

1. Alarm Lock.

2. Code Locks, LLC

3. Locknetics; an Ingersoll Rand company.

4. Kaba Ilco.

1.3.8 ELECTROMAGNETIC LOCKS

A. ANSI/BHMA A156.23

Electrically powered, of strength and configuration indicated; with electromagnet attached to frame and armature plate attached to door. Listed under Category E in BHMA's "Certified Product Directory."

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 12 of 30

(1) Type Full exterior or full interior, as required by application indicated.

(2) Strength Ranking 1000 lbf (4448 N).

(3) Inductive Kickback Peak Voltage Not more than 53 V.

(4) Residual Magnetism Not more than 4 lbf (18 N) to separate door from magnet.

B. Delayed-Egress Locks BHMA A156.24. Listed under Category G in BHMA's "Certified Product Directory".

(1) Means of Egress Doors Lock releases within 15 seconds after applying a force not more than 15 lbf (67 N) for not more than 3 seconds, as required by NFPA 101.

(2) Security Grade Activated from secure side of door by initiating device.

(3) Movement Grade Activated by door movement as initiating device.

C. Manufacturers Door Controls International.

Doorguard Systems, Inc.

Dortronics Systems, Inc.

DynaLock Corp.

Locknetics; an Ingersoll-Rand Company.

Rutherford Controls Int'l. Corp.

SARGENT Manufacturing Company; an ASSA ABLOY Group company.

Securitron Magnalock Corporation; an ASSA ABLOY Group company.

Security Door Controls.

1.3.9 CARD READERS

Provide and install card readers where indicated. Integrate card readers with other specified systems and systems that are in place.

1.3.10 ELECTRIC STRIKES

A. ANSI/ BHMA A156.31 Grade 1.

B. General: Use fail-secure electric strikes with fire-rated devices.

C. Manufacturers:

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 13 of 30

1. Adams Rite Manufacturing Co.

2. Folger Adam Security Inc.; an ASSA ABLOY Group company.

3. HES, Inc.; an ASSA ABLOY Group company.

4. Locknetics; an Ingersoll-Rand Company.

5. Precision Hardware, Inc.

6. Von Duprin; an Ingersoll-Rand Company.

1.3.11 KEYS

VA will supply keys.

1.3.12 ARMOR PLATES, COMBINATION KICK-MOP PLATES AND DOOR EDGING

A. Conform to ANSI Standard A156.6.

B. Provide protective plates and door edging as specified below:

1. Kick-mop plates and armor plates plastic or metal, Type J100 series, color as required.

2. Provide kick-mop plates for both sides of each door, except where noted as not required.

Kick-mop plates shall be 125 mm (5 inches) high. On push side of doors where jamb stop extends to floor, make combination kick-mop plates 38 mm (1-1/2 inches) less than width of door, except pairs of metal doors which shall have plates 25 mm (1 inch) less than width of each door. Extend all other combination kick-mop plates to within 6 mm (1/4 inch) of each edge of doors. Kick mop plates shall butt astragals. For jamb stop requirements, see specification sections pertaining to door frames.

3. Kick-mop plates are not required on following door sides:

a) Armor plate side of doors;

b) Exterior side of exterior doors;

c) Closet side of closet doors;

d) Storage side of doors to or from storage spaces; and

e) Both sides of aluminum entrance doors.

4. Armor plates for doors are listed under "Hardware Sets". Armor plates shall be 875 mm (35 inches) high and 38 mm (1-1/2 inches) less than width of doors, except on pairs of metal doors. Plates on pairs of metal doors shall be 25 mm (1 inch) less than width of each door.

Where top of intermediate rail of door is less than 875 mm (35 inches) from door bottom, extend armor plates to within 13 mm (1/2 inch) of top rail. On doors equipped with panic devices, extend armor plates to within 13 mm (1/2 inch) of panic bolt cross bar.

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 14 of 30

5. Where louver or grille occurs in lower portion of doors, substitute stretcher plate and kick-mop plate in place of armor plate. Size of stretcher plate and kick-mop plate shall be 125 mm (5 inches) high.

1.3.13 EXIT DEVICES

A. Conform to ANSI Standard A156.3. Exit devices shall be Grade 1; type and function are specified in hardware sets. Provide flush with finished floor strikes for vertical rod exit devices in interior of building. Trim shall have lever handles similar to locksets, unless otherwise specified.

B. Exit devices for fire doors shall comply with Underwriters Laboratories, Inc., requirements for Fire Exit Hardware. Submit proof of compliance.

1.3.14 WEATHERSTRIPS (FOR EXTERIOR DOORS)

Conform to ANSI A156.22. Air leakage shall not to exceed 0.50 CFM per foot of crack length (0.000774m3/s/m).

1.3.15 MISCELLANEOUS HARDWARE

A. Cylinders for Various Partitions and Doors: Key cylinders same as entrance doors of area in which partitions and door occur. Provide cylinders to operate locking devices where specified for following partitions and doors:

1. Folding doors and partitions.

2. Slide-up doors.

D. Mutes: Conform to ANSI A156.16. Provide door mutes or door silencers Type L03011, of white or light gray color, on each steel door frame, except lead-lined frames and frames for sound-resistant, lightproof and electromagnetically shielded doors. Furnish 3 mutes for single doors and 2 mutes for each pair of doors, except double-acting doors. Provide 4 mutes or silencers for frames for each Dutch type door. Provide 2 mutes for each edge of sliding door which would contact door frame.

1.3.16 PADLOCKS FOR VARIOUS DOORS, GATES AND HATCHES

A. ASTM E883, size 50 mm (2 inch) wide chain; furnish extended shackles as required by job conditions. Provide padlocks, with key cylinders, for each door in following areas as noted.

B. Key padlocks as follows:

1. Chain Link Fence Gates for Electrical Substation and other Fenced Buildings or Areas:

Engineer's set, except as otherwise specified.

2. Chain Link Fence Gates for Oxygen Storage: Maintenance supply set.

3. Roof Access and Scuttles: Engineer's set.

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 15 of 30

1.3.17 Exam Room “Barn Door” Hardware (Basis of Design – Aurora Doors)

A. Components:

(1) Single Top Track

(2) Floor Guide: Integral Jamb

(3) Valances: Extruded aluminum with integral end caps

(4) Top Rollers: Tandem nylon roller sized to match door weight

B. Accessories:

(1) Soft Closer: Soft and Self-closing mechanism at one side of door leaf.

(2) Handles: Ladder pull: 16” long x 1” diameter. Finish: US32D Satin Stainless Steel.

(3) Door Locks: “ADA” Thumbturn inside with keyed cylinder outside”, FSB Sliding door lock (finish US32D).

1.3.18 HARDWARE SETS

Following sets of hardware correspond to hardware numbers shown in Room Finish and Door Schedule. Where hardware set for a single door is specified for a pair of doors; equip each leaf of such pair of doors with set noted. Only those hardware sets that are referenced in the Schedule will be required. Disregard breaks in hardware set numbering sequence. Disregard hardware sets listed below but not shown in Schedule.

Hardware Consultant working on a project will be responsible for providing additional information regarding these hardware sets. The numbers shown in the following sets come from BHMA standards.

ELECTRIC HARDWARE ABBREVIATIONS LEGEND:

ADO = Automatic Door Operator EMCH = Electro-Mechanical Closer-Holder MHO = Magnetic Hold-Open (wall- or floor-mounted)

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 16 of 30

HARDWARE SETS (not all sets may be used on this project)

HW-1

(1) Continuous Hinge

(1) Door Pull w/ Plate J401 x J302

(1) Push Plate J302

(1) Kick Plate J102

(1) Mop Plate @ Inswing Door J103

(1) Closer C02011/C02021

(1) Floor Stop L02121 x 3 Fasteners

(3) Silencers L03011

HW-1A

Hinges as Required

(1) Latchset F75

(1) Closer C02011/C02021 x Install Outside Room

(1) Kick Plate J102

(1) Mop Plate @ Inswing Doors J103

(1) Floor Stop L02121 x 3 Fasteners

(1) Threshold J32300 x 57 mm Width (2 ¼”)

(1) Auto Door Bottom R0Y346 – Heavy Duty

(1) Set Seals R0Y164

HW-1F

(1) Continuous Hinge

(1) Latchset F75

(1) Kick Plate J102

(1) Wall Stop L02101

(3) Silencers L03011

HW-1L

(1) Continuous Hinge

(1) Latchset F75

(1) Kick Plate J102

(1) Wall Stop L02101

(1) Threshold J32300 x 57 mm Width (2 ¼”)

(1) Auto Door Bottom R0Y346 – Heavy Duty

(2) Sets Self-Adhesive Seals R0Y154

HW-1M

(1) Floor Closer C06011

(2) Push Plates J302

(2) Kick Plates J102

(2) Edge Guards @ Wood Doors J209M/J212

(1) Overhead Stop C01541 – Adjustable

HW-1P

(1) Floor Closer C6062

(2) Push Plate J302 8” x 6”

(2) Kick Plates J102

(2) Edge Guards @ Wood Doors J209M/J212

(1) Overhead Stop C01541 – Adjustable

HW-1Q

(1) Continuous Hinge

(1) Latchset F75

(1) Kick Plate J102

(1) Closer C02011/C02021

(1) Wall Stop L02101

(1) Threshold J32300 x 57 mm Width (2 ¼”)

(1) Auto Door Bottom R0Y346 – Heavy Duty

(2) Sets Self-Adhesive Seals R0Y154

HW-2

Hinges as Required

(1) Keyed Privacy Indicator Lock F90 x Occupancy Indicator

(1) Closer C02011/C02021

(1) Kick Plate J102

(1) Mop Plate @ Inswing Door J103

(1) Floor Stop L02121 x 3 Fasteners

(1) Set Self-Adhesive Seals R0Y154

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 17 of 30

HW-2A (ADO Door)

(1) Continuous Transfer Hinge x integral hinge guard channel x adjusta-screws x 8-thruwire transfer x in-hinge access panel

(1) Keyed Privacy Indicator Lock F13 x Occupancy Indicator

(1) Electric Strike E09391 (fail-secure), 24vdc

(1) Power Supply regulated, filtered, 24vdc, amperage as required

(1) Kick Plate J102

(1) Mop Plate @ Inswing Door J103

(1) Edge Guard @ Wood Doors J208M/J211 (verify), cut: hardware

(1) Wall Stop L02101

(1) Threshold J32300 x 57 mm Width (2 ¼”)

(1) Auto Door Bottom R0Y346 – Heavy Duty

(2) Sets Self-Adhesive Seals R0Y154

HW-2B (Barn Type Sliding Door)

(2) End Cap C-110 EC Clr Anod

(1) Fascia C-110 F Clr Anod (per ft)

(1) Barn Door Track Kit C-994-108 OR C-993- 108 OR C-911-108 as req'd.

(1) Sliding Door Lock 9100ADAL-5

NOTE: barn door track kit includes track, hangers, stops and guides.

HW-2C

Hinges as Required

(1) Privacy Lock F76-MOD x Occupancy Indicator

(1) Kick Plate J102

(1) Mop Plate @ Inswing Door J103

(1) Wall Stop L02101

(3) Silencers L03011

HW-2F

(1) Continuous Hinge

(1) Privacy Lock F76-MOD x Occupancy Indicator

(1) Kick Plate J102

(1) Wall Stop L02101

(1) Threshold J32300 x 57 mm Width (2 ¼”)

(1) Auto Door Bottom R0Y346 – Heavy Duty

(2) Sets Self-Adhesive Seals R0Y154

HW-2G

Hinges as Required

(1) Keyed Privacy Indicator Lock F90 x Occupancy Indicator

(1) Closer C02011/C02021

(1) Kick Plate J102

(1) Mop Plate @ Inswing Door J103

(1) Floor Stop L02121 x 3 Fasteners

(1) Auto Door Bottom R0Y345 – Heavy Duty

(2) Sets Self-Adhesive Seals R0Y154

HW-2J

Hinges as Required

(1) Privacy Lock F76-MOD x Occupancy Indicator

(1) Kick Plate J102

(1) Mop Plate @ Inswing Door J103

(1) Wall Stop L02121

(1) Auto Door Bottom R0Y345 – Heavy Duty

(2) Sets Self-Adhesive Seals R0Y154

RESCUE HARDWARE ON INSWINGING

DOORS

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 18 of 30

HW-3

Hinges as Required

(1) Office Lock F82

(1) Closer C02011/C02021

(1) Kick Plate J102

(1) Floor Stop L02121 x 3 Fasteners

(1) Set Self-Adhesive Seals R0Y154

HW-3E

Hinges as Required

(1) Office Lock F82

HW-3F

(1) Continuous Hinge x Integral Hinge Guard Channel and Adjusta-Screws

(1) Office Lock F82

(1) Closer C02011/C02021 at rated door

(1) Kick Plate J102

(1) Edge Guard (at wood door) J208M/J211 (verify), cut hardware

(1) Floor Stop L02121 x 3 Fasteners

(1) Threshold J32300 x 57 mm Width (2 ¼”)

(1) Auto Door Bottom R0Y346 – Heavy Duty

(1) Set Sound/Light Seals R0Y154

HW-3G

Hinges as Required

(1) Office Lock F82

(1) Floor Stop L02121 x 3 Fasteners

(1) Door Viewer (Mental Health Only) L03221

- 190° (View Into Corridor)

(1) Threshold J32300 x 57 mm Width (2 ¼”)

(1) Auto Door Bottom R0Y346 – Heavy Duty

(2) Set Self-Adhesive Seals R0Y154

OMIT VIEWER IF DOOR PROVIDED WITH

VISION LITE.

HW-3J

(1) Continuous Hinge x Integral Hinge Guard Channel and Adjusta-Screws

(1) Office Lock F82

(1) Kick Plate J102

(1) Wall Stop L02101

(1) Threshold J32300 x 57 mm Width (2 ¼”)

(1) Set Sound/Light Seals R0Y264/R0Y255

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 19 of 30

HW-4B

(1) Continuous Hinge

(1) Public Restroom Lock F88

(1) Closer C02011/C02021

(1) Closer C02051/C02061

(1) Mop Plate @ Inswing Door J103

(1) Floor Stop @ Outswing Door L02121 x 3 Fasteners

(1) Wall Stop @ Inswing Door L02121

(1) Threshold J32300 x 57 mm Width (2 ¼”)

(1) Auto Door Bottom R0Y346 – Heavy Duty

(2) Sets Self-Adhesive Seals R0Y154

PROVIDE NON-HOLD-OPEN CLOSER AT

TOILET ROOMS.

HW-4C

(1) Continuous Hinge x Integral Hinge Guard Channel and Adjusta-Screws

(1) Hospital Utility Lock F09 x Paddles Pointing Down

(1) Key Cylinder as Required

(1) Closer C02011/C02021

(1) Armor Plate J101 x 1.275 mm (0.050”) Thickness

(1) Edge Guard @ Wood Doors J209M/J212

(1) Overhead Stop C01541 – Adjustable

(1) Threshold J32300 x 57 mm Width (2 ¼”)

(1) Auto Door Bottom R0Y346 – Heavy Duty

(1) Set Seals R0Y164

HW-4D

(1) Continuous Hinge x Integral Hinge Guard Channel and Adjusta-Screws

(1) Classroom Lock F81

(1) Closer C02011/C02021

(1) Armor Plate J101 x 1.275 mm (0.050”) Thickness

(1) Mop Plate @ Inswing Door J103

(1) Edge Guard @ Wood Doors J209M/J212

(1) Floor Stop @ Outswing Door L02121 x 3 Fasteners

(1) Wall Stop @ Inswing Door L02121

(1) Set Self-Adhesive Seals R0Y154

HW-4E

Hinges as Required

(1) Utility Lock F88

(1) Closer (at rated doors) C02011/C02021

(1) Closer (at non-rated doors) C02051/C02061

(1) Kick Plate J102

(1) Floor Stop L02121 x 3 Fasteners

(1) Threshold J32300 x 57 mm Width (2 ¼”)

(2) Sets Self-Adhesive Seals R0Y154

HW-4F

Channel and Adjusta-Screws

(1) Utility Lock F88

(1) Armor Plate J101 x 1.275 mm (0.050”) Thickness

(1) Edge Guard @ Wood Doors J209M/J212

(1) Floor Stop @ Outswing Door L02121 x 3 Fasteners

(1) Wall Stop @ Inswing Door L02121

HW-4G

Channel and Adjusta-Screws

(1) Utility Lock F88

(1) Closer (at rated doors) C02011/C02021

(1) Kick Plate J102

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 20 of 30

HW-4J

Hinges as Required

(1) Classroom Lock F81

(1) Closer C02011/C02021

(1) Kick Plate J102

(1) Wall Stop L02101

(1) Threshold J32300 x 57 mm Width (2 ¼”)

(1) Auto Door Bottom R0Y346 – Heavy Duty

(2) Set Self-Adhesive Seals R0Y154

HW-4K

(1) Continuous Hinge x Integral Hinge Guard Channel and Adjusta-Screws

(1) Utility Lock F88

(1) Armor Plate J101 x 1.275 mm (0.050”) Thickness

(1) Edge Guard @ Wood Doors J209M/J212

(1) Floor Stop L02121 x 3 Fasteners

(1) Set Self-Adhesive Seals R0Y154

HW-4M

(1) Continuous Hinge x Integral Hinge Guard Channel and Adjusta-Screws

(1) Classroom Hospital Lock F08 x Paddles Pointing Down

(1) Heavy Duty Armor Plate J101 x 3.175 mm (0.125”) Thickness

(1) Edge Guard @ Wood Doors J209M/J212

(1) Floor Stop L02121 x 3 Fasteners

(1) Set Self-Adhesive Seals R0Y154

HW-4N

(1) Continuous Hinge x Integral Hinge Guard Channel and Adjusta-Screws

(1) Utility Lock F88

(1) Closer (at rated doors) C02011/C02021

(1) Kick Plate J102

(1) Edge Guard @ Wood Doors J209M/J212

(1) Floor Stop L02121 x 3 Fasteners

(1) Threshold J32300 x 57 mm Width (2 ¼”)

(1) Auto Door Bottom R0Y346 – Heavy Duty

(2) Set Self-Adhesive Seals R0Y154

HW-4P

(1) Continuous Hinge x Integral Hinge Guard Channel and Adjusta-Screws

(1) Classroom Hospital Lock F08 x Paddles Pointing Down

(1) Armor Plate J101 x 1.275 mm (0.050”) Thickness

(1) Edge Guard @ Wood Doors J209M/J212

(1) Overhead Stop C01541 – Adjustable

(1) Threshold J32300 x 57 mm Width (2 ¼”)

(1) Auto Door Bottom R0Y346 – Heavy Duty

(2) Sets Self-Adhesive Seals R0Y154

HW-4Q

(1) Pivot Set C07162 x 454kg (1000lbs) weight capacity

(1) Intermediate Pivot C07311

(1) Utility Hospital Lock F09 x Lead-Lined x Paddles Pointing Down

(1) Armor Plate J101 x 1.275 mm (0.050”) Thickness

(1) Edge Guard @ Wood Doors J209M/J212

(1) Overhead Stop C01541 – Adjustable

(1) Set Self-Adhesive Seals R0Y154

HW-4S

(1) Continuous Hinge x Integral Hinge Guard Channel and Adjusta-Screws

(1) Classroom Lock F81

(1) Heavy Duty Armor Plate J101 x 3.175 mm (0.125”) Thickness

(1) Edge Guard @ Wood Doors J209M/J212

(1) Floor Stop L02121 x 3 Fasteners

(1) Auto Door Bottom R0Y346 – Heavy Duty

(2) Sets Self-Adhesive Seals R0Y154

HW-4T

(1) Continuous Hinge x Integral Hinge Guard Channel and Adjusta-Screws

(1) Classroom Hospital Lock F08 x Paddles Pointing Down

(1) Armor Plate J101 x 1.275 mm (0.050”) Thickness

(1) Edge Guard @ Wood Doors J209M/J212

(1) Overhead Stop C01541 – Adjustable

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 21 of 30

HW-4U

(1) Continuous Hinge

(1) Public Restroom Lock F88

(1) Closer C02011/C02021

(1) Closer C02051/C02061

(1) Kick Plate J102

(1) Mop Plate @ Inswing Door J103

(1) Floor Stop @ Outswing Door L02121 x 3 Fasteners

(1) Wall Stop @ Inswing Door L02121

(1) Set Self-Adhesive Seals R0Y154

PROVIDE NON-HOLD-OPEN CLOSER AT

TOILET ROOMS.

HW-4V

(1) Pivot Set C07162 x 454kg (1000lbs) weight capacity

(1) Intermediate Pivot C07311

(1) Utility Hospital Lock F09 x Lead-Lined x Paddles Pointing Down

(1) Closer C02011/C02021 x Metal Lead-Lined Cover

(1) Armor Plate J101 x 1.275 mm (0.050”) Thickness

(2) Edge Guards @ Wood Doors J209M/J212

(1) Overhead Holder-Stop C01541 – Adjustable

(1) Set Self-Adhesive Seals R0Y154

HW-5

Hinges as Required

(1) Storeroom Lock F86

(1) Closer C02011/C02021

(1) Kick Plate J102

(1) Floor Stop L02121 x 3 Fasteners

(1) Set Self-Adhesive Seals R0Y154

HW-5B

(1) Continuous Hinge x Integral Hinge Guard Channel and Adjusta-Screws

(1) Storeroom Lock F86

(1) Closer C02011/C02021

(1) Armor Plate J101 x 1.275 mm (0.050”) Thickness

(1) Edge Guard @ Wood Doors J209M/J212

(1) Wall Stop L02101

(1) Set Self-Adhesive Seals R0Y154

HW-5D

Hinges as Required

(1) Storeroom Lock F86

(1) Kick Plate J102

(1) Floor Stop L02121 x 3 Fasteners

(1) Wall Stop @ Inswing Door L02121

(3) Silencers L03011

HW-5E

Channel and Adjusta-Screws

(1) Storeroom Lock F13-MOD x Rigid Outside Lever x Key Retracts Deadbolt and Latchbolt

(1) Armor Plate J101 x 1.275 mm (0.050”) Thickness

(1) Edge Guard @ Wood Doors J209M/J212

(1) Floor Stop L02121 x 3 Fasteners

(1) Set Self-Adhesive Seals R0Y154

HW-5F

(1) Continuous Hinge x Integral Hinge Guard Channel and Adjusta-Screws

(1) Storeroom Lock F86

(1) Closer C02011/C02021

(1) Heavy Duty Armor Plate J101 x 3.175 mm (0.125”) Thickness

(1) Edge Guard @ Wood Doors J209M/J212

(1) Floor Stop L02121 x 3 Fasteners

(1) Set Self-Adhesive Seals R0Y154

HW-5G

Hinges as Required

(1) Storeroom Lock F86

(1) Kick Plate J102

(1) Floor Stop L02121 x 3 Fasteners

(1) Threshold J32300 x 57 mm Width (2 ¼”)

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 22 of 30

HW-5H

Hinges as Required

(1) Dutch Door Bolt L04161 - 4” @ Top Leaf

(1) Storeroom Lock F86@ Bottom Leaf

(1) Kick Plate J102

(1) Floor Stop L02121 x 3 Fasteners

(1) Wall Stop @ Inswing Door L02121

(1) Set Self-Adhesive Seals R0Y154

HW-6D

(1) Key Cylinder as Required

BALANCE OF HARDWARE FURNISHED WITH

INTEGRATED DOOR ASSEMBLY.

PROVIDE AUTO DOOR OPERATOR AND

CONTROLS.

HW-6E

Channel and Adjusta-Screws

(1) Exit Device Type 1 F08 Lever

(1) Key Cylinder as Required

(1) Kick Plate J102

(1) Edge Guard @ Wood Doors J209M/J212

(1) Floor Stop L02121 x 3 Fasteners

(1) Set Self-Adhesive Seals R0Y154

HW-6F

(1) Continuous Hinge x Integral Hinge Guard Channel and Adjusta-Screws x 8-Thruwire Transfer x In-Hinge Access Panels

(1) Elec. Exit Device Type 1 F08 Lever (E04)

(1) Power Supply By Exit MFR. For E04 Function

(1) Armor Plate J101 x 1.275 mm (0.050”) Thickness

(1) Edge Guard @ Wood Doors J209M/J212

(1) Floor Stop L02121 x 3 Fasteners

(1) Set Self-Adhesive Seals R0Y154

POWER TRANSFER SHARED BY ELECTRIC

PANEL AND RE-ACTIVATION SENSOR

WIRING PROVIDE RE-ACTIVATION

SENSORS.

PROVIDE AUTO DOOR OPERATORS AND

CONTROLS.

HW-7

(1) Key Cylinder (for Keyswitch) as Required

BALANCE OF HARDWARE SUPPLIED

WITH COILING DOORS AND GRILLES

HW-7B

(1) Key Cylinder as Required

BALANCE OF HARDWARE SUPPLIED WITH

SHIELDED DOOR ASSEMBLY

HW-8

ALL HARDWARE FURNISHED WITH

INTEGRATED DOOR ASSEMBLY.

HW-8C

(2) Double-Acting Floor Closers C06011

(4) Push Plates J302 8” x 16”

(4) Heavy Duty Armor Plates J101 x 3.175 mm (0.125”) Thickness

(4) Edge Guards @ Wood Doors J209M/J212

(2) Overhead Holders C01511 – Adjustable

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 23 of 30

HW-8D

(2) Pivot Sets C07162

(2) Intermediate Transfer Pivots C07321 x 4- Wires

(2) Intermediate Pivots C07311

(2) Push/Pull Bar Sets J505 – 305 mm (12”) Center-to-Center Pull

(2) Overhead Stops C01541 – Adjustable

HW-10B

(2) Continuous Hinges x Integral Hinge Guard Channel and Adjusta-Screws

(1) Set Auto Flush Bolts Type 25 Less Bottom Bolt

(1) Classroom Hospital Lock F08 x Paddles Pointing Down

(1) Overlapping Astragal with Self-Adhesive Seal R0Y634 x R0Y154 x Thru-Bolts

(1) Closer (at rated doors) C02011/C02021

(2) Heavy Duty Armor Plate J101 x 3.175 mm (0.125”) Thickness

(2) Edge Guards @ Wood Doors J208M/J211

(2) Floor Stops L02121 x 3 Fasteners

INSTALL LOCK TRIM PROTECTOR BAR ON

PUSH SIDE OF ACTIVE LEAF TO PROTECT

TRIM.

HW-10C

(2) Continuous Hinges x Integral Hinge Guard Channel and Adjusta-Screws

(1) Set Auto Flush Bolts Type 25 Less Bottom Bolt

(1) Utility Lock F88

(1) Overlapping Astragal with Self-Adhesive Seal R0Y634 x R0Y154 x Thru-Bolts

(2) Kick Plates J102

(1) Edge Guard @ Wood Doors J208M/J211

(2) Floor Stops L02121 x 3 Fasteners

(1) Set Self-Adhesive Seals R0Y154

HW-10D

Hinges as Required

(1) Set Auto Flush Bolts Type 25 Less Bottom Bolt

(1) Classroom Lock F81

(1) Overlapping Astragal with Self-Adhesive Seal R0Y634 x R0Y154 x Thru-Bolts

(2) Kick Plates J102

(2) Floor Stops L02121 x 3 Fasteners

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 24 of 30

HW-10E

(2) Pivot Sets C07162 x 454kg (1000lbs) Weight Capacity

(2) Intermediate Pivots C07311

(1) Set Auto Flush Bolts Type 25 Less Bottom Bolt

(1) Classroom Lock F81 x Lead Lined x Paddles Pointing Down

(1) Overlapping Astragal with Self-Adhesive Seal R0Y634 x R0Y154 x Thru-Bolts x Lead Lined

(2) Armor Plates J101 x 1.275 mm (0.050”) Thickness

(4) Edge Guards @ Wood Doors J208M/J211

(2) Floor Stops L02121 x 3 Fasteners

(1) Set Self-Adhesive Seals R0Y154

HW-10H

(2) Bottom Pivots C07162 x 454kg (1000lbs) Weight Capacity

(1) Intermediate Pivot C07311 (Middle of Active Leaf)

(1) Intermediate Transfer Pivot C07321 x 4- Wires (Middle of Inactive Leaf)

(1) Intermediate Transfer Pivot C07321 x 4- Wires (Near Top of Each Leaf)

(1) Set Auto Flush Bolts Type 25 Less Bottom Bolt

(1) Hospital Utility Lock F09 x Paddles Pointing Down x Lead-Lined

(1) Electric Unlatch Strike E09321 (Fail Secure) (Lead-Lined)

(1) Power Supply Regulated, Filtered, 24VDC, Amperage as Required

(1) Coordinator Type 21A

(1) Overlapping Astragal with Self-Adhesive Seal R0Y634 x R0Y154 x Thru-Bolts x Lead Lined

(2) Armor Plates J101 x 1.275 mm (0.050”) Thickness

(4) Edge Guards @ Wood Doors J208M/J211

(2) Overhead Stops C01541 – Adjustable

(1) Set Self-Adhesive Seals R0Y154

PROVIDE AUTOMATIC DOOR OPERATOR

AND CONTROLS.

PROVIDE POWER TRANSFER PIVOTS NEAR

TOP OF EACH DOOR FOR RE-ACTIVATION

SENSOR WIRING AND PROVIDE RE-

ACTIVATION SENSORS.

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 25 of 30

HW-11

Hinges as Required

(1) Set Auto Flush Bolts Type 25 Less Bottom Bolt

(1) Storeroom Lock F86

(1) Coordinator Type 21A

(1) Overlapping Astragal with Self-Adhesive Seal R0Y634 x R0Y154 x Thru-Bolts

(2) Closers C02011/C02021

(2) Kick Plates J102 (@ Storage Rooms Only)

(2) Floor Stops L02121 x 3 Fasteners

(1) Set Self-Adhesive Seals R0Y154

HW-11A

(2) Continuous Hinges x Integral Hinge Guard Channel and Adjusta-Screws

(1) Set Auto Flush Bolts Type 25

(1) Security Storeroom Lock F13-MOD x Rigid Outside Lever x Key Retracts Deadbolt and Latchbolt

(1) Overlapping Astragal with Self-Adhesive Seal R0Y634 x R0Y154 x Thru-Bolts

(2) Armor Plates J101 x 1.275 mm (0.050”) Thickness

(2) Edge Guards @ Wood Doors J208M/J211

(2) Floor Stops L02121 x 3 Fasteners

(1) Set Self-Adhesive Seals R0Y154

HW-11B

(2) Continuous Hinges x Integral Hinge Guard Channel and Adjusta-Screws

(1) Set Auto Flush Bolts Type 25

(1) Storeroom Lock F86

(1) Coordinator Type 21A

(1) Overlapping Astragal with Self-Adhesive Seal R0Y634 x R0Y154 x Thru-Bolts

(2) Closers C02011/C02021

(2) Armor Plates J101 x 1.275 mm (0.050”) Thickness

(2) Edge Guards @ Wood Doors J208M/J211

(2) Floor Stops L02121 x 3 Fasteners

(1) Set Self-Adhesive Seals R0Y154

HW-11C

Hinges as Required

(1) Set Auto Flush Bolts Type 25 Less Bottom Bolt

(1) Storeroom Lock F86

(1) Coordinator Type 21A

(1) Overlapping Astragal with Self-Adhesive Seal R0Y634 x R0Y154 x Thru-Bolts

(2) Closers C02011/C02021

(2) Kick Plates J102 (@ Storage Rooms Only)

(2) Floor Stops L02121 x 3 Fasteners

(1) Threshold J32300 x 57 mm Width (2 ¼”)

(2) Auto Door Bottoms R0Y346 – Heavy Duty

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 26 of 30

HW-12H

(2) Continuous Transfer Hinges x Integral Hinge Guard Channel and Adjusta-Screws x 8-Thruwire Transfer x In-Hinge Access Panel

(1) Elec. Exit Device Type 7 or 8 F01 (E04)

(1) Elec. Exit Device Type 7 or 8 F08 Lever (E04)

(1) Key Cylinder as Required

(1) Power Supply by Exit Mfr. For E04 Function

(1) Set Meeting Stile Astragals R0Y834

(2) Kick Plates J102

(2) Edge Guards @ Wood Doors J208M/J211

(2) Auto Door Bottoms R0Y346 – Heavy Duty

(2) Sets Self-Adhesive Seals R0Y154

POWER TRANSFER SHARED BY

ELECTRIC PANEL AND RE-ACTIVATION

SENSOR WIRING.

PROVIDE RE-ACTIVATION SENSORS.

PROVIDE AUTO DOOR OPERATORS AND

CONTROLS.

HW-12B

(1) Key Cylinder TYPE AS REQUIRED

BALANCE OF HARDWARE FURNISHED WITH

PROVIDE AUTO DOOR OPERATOR AND

CONTROLS.

HW-13

ALL HARDWARE SUPPLIED WITH

ENTRANCE DOOR(S).

HW-E4

(1) Transfer Hinge 4-Wire Type as Required

(1) Electrified Lock F07 (E01-REX, E06) 24VDC

(1) Power Supply Regulated, Filtered, 24VDC, Amperage as Required

(1) Key Cylinder as Required

(1) Closer C02011

(1) Kick Plate J102

(1) Floor Stop L02121 x 3 Fasteners

(1) Threshold J32120 x Silicone Gasket

(1) Door Sweep R0Y416

(1) Set Frame Seals R0Y164

(1) Drip R0Y976

(1) Alarm Contact

PROVIDE 120VAC POWER, CONDUIT, AND

WIRING; AND CARD READER.

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 27 of 30

HW-E4A

(1) Continuous Hinge

(1) Anti-Vandal Pull

(1) Exit Device Type 1 F03 Less Trim

(1) Latch Protector (outswing doors)

(1) Key Cylinder as Required

(1) Closer C02011

(1) Kick Plate J102

(1) Floor Stop L02121 x 3 Fasteners

(1) Threshold J32120 x Silicone Gasket

(1) Door Sweep R0Y416

(1) Set Frame Seals R0Y164

(1) Drip R0Y976

(1) Alarm Contact

HW-E6

(2) Continuous Hinges

(1) Set Auto Flush Bolts Type 25

(1) Dust Proof Strike L04021

(1) Entry Lock F11

(1) Overlapping Astragal with Self-Adhesive Seal R0Y634 x R0Y154 x Thru-Bolts

(1) Coordinator Type 21A

(2) Closers C02011/C02021

(2) Kick Plates J102

(2) Floor Stops L02121 x 3 Fasteners

(1) Threshold (outswing door) J32120 x Silicone Gasket

(1) Threshold (inswing door) Aluminum

(2) Door Sweeps R0Y416

(1) Set Frame Seals R0Y164

(1) Drip R0Y976

HW-SH-2

(1) Continuous Hinge

(1) Door Pull w/ Plate J401 x J302

(1) Lock Detention Type

(1) Strike/Keeper as Required

(1) Overhead Stop C01541 – Adjustable x Sec Torx

(1) Door Position Switch

HW-SH-3

Hinges as Required

(1) Transfer Hinge 4-Wire Type as Required

(1) Electrified Lock F07 (E01-REX, E06) 24VDC

(1) Power Supply Regulated, Filtered, 24VDC, Amperage as Required

(1) Closer C02011/C02021

(1) Floor Stop L02121 x 3 Fasteners

(1) Threshold J32300 x 57 mm Width (2 ¼”)

(1) Auto Door Bottom R0Y346 – Heavy Duty

(2) Sets Self-Adhesive Seals R0Y154

(1) Alarm Contact

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 28 of 30

HW-SH-3B

(1) Continuous Hinge

(1) Push-Button Combination Lock N3 – A156.13 F86 G1 E06

(1) Closer C02011/C02021

(1) Kick Plate J102

(1) Mop Plate @ Inswing Door J103

(1) Floor Stop L02121 x 3 Fasteners

(1) Set Self-Adhesive Seals R0Y154

HW-SH-3C

(1) Continuous Hinge x Integral Hinge Guard Channel and Adjusta-Screws

(1) Push-Button Combination Lock N3 – A156.13 F86 G1 E06

(1) Closer C02011/C02021

(1) Armor Plate J101 x 1.275 mm (0.050”) Thickness

(1) Edge Guard @ Wood Doors J208M/J211

(1) Floor Stop L02121 x 3 Fasteners

(1) Wall Stop @ Inswing Door L02121

(1) Set Self-Adhesive Seals R0Y154

HW-SH-3D

(1) Continuous Hinge x Integral Hinge Guard Channel and Adjusta-Screws x 4-Thruwire Transfer x In-Hinge Access Panel

(1) Electrified Lock F07 (E01-REX, E06)

24VDC

(1) Power Supply Regulated, Filtered, 24VDC, Amperage as Required

(1) Closer C02011/C02021

(1) Armor Plate J101 x 1.275 mm (0.050”) Thickness

(1) Edge Guard @ Wood Doors J208M/J211

(1) Floor Stop L02121 x 3 Fasteners

(1) Threshold J32300 x 57 mm Width (2 ¼”)

(1) Auto Door Bottom R0Y346 – Heavy Duty

(2) Sets Self-Adhesive Seals R0Y154

(1) Alarm Contact PROVIDE 120VAC

POWER, CONDUIT, AND WIRING; AND

CARD READER.

HW-SH-3F

(1) Continuous Hinge x Integral Hinge Guard Channel and Adjusta-Screws x 4-Thruwire Transfer x In-Hinge Access Panel

(1) Electrified Lock F13-MOD x Rigid Outside Lever x Key Retracts Latchbolt and Deadbolt

(E01-REX, E06) 24VDC

(1) Power Supply Regulated, Filtered, 24VDC, Amperage as Required

(1) Closer C02011/C02021

(1) Armor Plate J101 x 1.275 mm (0.050”) Thickness

(1) Edge Guard @ Wood Doors J208M/J211

(1) Floor Stop L02121 x 3 Fasteners

(1) Set Self-Adhesive Seals R0Y154

(1) Alarm Contact

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 29 of 30

HW-SH-3H

(1) Continuous Hinge x 4-Thruwire Transfer x In-Hinge Access Panel

(1) Electrified Lock F13-MOD x Rigid Outside Lever x Key Retracts Latchbolt and Deadbolt

(E01-REX, E06) 24VDC

(1) Power Supply Regulated, Filtered, 24VDC, Amperage as Required

(1) Closer C02011/C02021

(1) Kick Plate J102

(1) Floor Stop L02121 x 3 Fasteners

(1) Set Self-Adhesive Seals R0Y154

(1) Door Viewer L03221 - 190°

(1) Alarm Contact

PROVIDE 120VAC POWER, CONDUIT, AND

WIRING; AND CARD READER.

HW-SH-4

(1) Key Cylinder as Required

BALANCE OF HARDWARE SUPPLIED WITH

INTEGRATED DOOR ASSEMBLY.

HW-SH-9

Hinges as Required

(1) Transfer Hinge 4-Wire Type as Required

(1) Set Auto Flush Bolts Type 25 Less Bottom Bolt

(1) Dust Proof Strike L04021

(1) Electrified Lock F07 (E01-REX, E06)

24VDC

(1) Power Supply Regulated, Filtered, 24VDC, Amperage as Required

(1) Coordinator Type 21A

(1) Overlapping Astragal with Self-Adhesive Seal R0Y634 x R0Y154 x Thru-Bolts

(2) Closers C02011/C02021

(2) Kick Plates J102 (@ Storage Rooms Only)

(2) Floor Stops L02121 x 3 Fasteners

(1) Set Self-Adhesive Seals R0Y154

(2) Alarm Contacts

PROVIDE 120VAC POWER, CONDUIT, AND

WIRING; AND CARD READER.

HW-SH-10

(1) Key Cylinder as Required

BALANCE OF HARDWARE SUPPLIED WITH

Part VI: Schedule E – Room Finish, Door & Hardware -- Page 30 of 30

HW-SH-10A

(1) Key Cylinder as Required

BALANCE OF HARDWARE SUPPLIED

WITH INTEGRATED DOOR ASSEMBLY.

PROVIDE AUTO DOOR OPERATOR AND

CONTROLS.

SECTION 1 ROOM FINISH, DOOR AND HARDWARE SCHEDULE--GENERAL
1.1 ROOM FINISHES, DOOR AND HARDWARE SCHEDULE
1.1.1 USE OF SCHEDULE E
1.1.2 OTHER REQUIREMENTS
A. Safety Glass
B. Laminated Fire Glass shall be used in fire rated assemblies
C. Wall Protection at Drinking Fountains and Lavatories
1.2 DOORS
1.2.1 DOORS
1.2.2 DOOR TYPES
1.2.3 DOOR SIZES
1.3 FINISH HARDWARE
1.3.1 GENERAL
A. Hardware Set Numbers on Schedule
B. Manufacturers' Catalog Number References
C. Keying
1.3.2 BUTT HINGES
A. ANSI A156.1.
(1) Exterior Doors
(2) Interior Doors
(3) Automatic doors hung on butts
(4) Labeled Wood Fire Doors
1.3.3 CONTINUOUS HINGES
A. ANSI/BHMA A156.26
(1) Listed under Category N in BHMA's "Certified Product Directory."
B. General
(1) Fire Pins
C. Continuous, Barrel-Type Hinges
(1) Base Metal for Exterior Hinges
(2) Base Metal for Interior Hinges
(3) Base Metal for Hinges for Fire-Rated Assemblies
(4) Manufacturers
D. Continuous, Gear-Type Hinges
(1) Manufacturers
1.3.4 DOOR CLOSING DEVICES
1.3.5 DOOR STOPS
1.3.6 LOCKS AND LATCHES
1.3.7 PUSH-BUTTON COMBINATION LOCKS
1.3.8 ELECTROMAGNETIC LOCKS
A. ANSI/BHMA A156.23
(1) Type
(2) Strength Ranking
(3) Inductive Kickback Peak Voltage
(4) Residual Magnetism
B. Delayed-Egress Locks
(1) Means of Egress Doors
(2) Security Grade
(3) Movement Grade

C. Manufacturers

1.3.9 CARD READERS
1.3.10 ELECTRIC STRIKES
1.3.11 KEYS
1.3.12 ARMOR PLATES, COMBINATION KICK-MOP PLATES AND DOOR EDGING
1.3.13 EXIT DEVICES
1.3.14 WEATHERSTRIPS (FOR EXTERIOR DOORS)
1.3.15 MISCELLANEOUS HARDWARE
1.3.16 PADLOCKS FOR VARIOUS DOORS, GATES AND HATCHES
1.3.17 Exam Room “Barn Door” Hardware (Basis of Design – Aurora Doors)
1.3.18 HARDWARE SETS