Utility Legend Symbols.pdf
PDF 190 KB Posted
- Attached to
- Rebid RFB for EMS Station 12 Fencing
- Solicitation number
- 471-04202026
- Issued by
- Warren County, North Carolina
About this file
This utility legend symbols document provides a comprehensive reference guide for interpreting utility infrastructure maps used by Wayne County and Seymour Johnson Air Force Base in North Carolina. The document categorizes utility symbols across multiple infrastructure layers including electric, fuel, natural gas, sewer, water, stormwater, thermal, and communication systems. Each symbol represents specific utility components such as meters, valves, pumps, storage tanks, pipe lines, and associated infrastructure features. The legend enables stakeholders to accurately read and interpret utility maps that depict the location and status of both active and abandoned utility systems across the service area.
The utility legend serves as a technical reference tool for the EMS Station 12 fencing project located at 2510 East Elm Street on Seymour Johnson Air Force Base in Goldsboro, North Carolina. Bidders responding to Wayne County's Request for Bids for fence removal and installation must use this symbology to understand existing utility infrastructure that may impact the project scope. The legend distinguishes between operational and abandoned utilities through visual differentiation and organizes symbols by utility type and function, allowing project teams to identify potential conflicts or considerations during fence work planning and execution. The document does not contain pricing information, set-asides, or contract terms but rather functions as a technical specification document necessary for accurate project planning and bidder understanding of site conditions.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Perimeter Fence.pdf | ||
| EMS STATION-Haul Route.pdf | ||
| EMS Station Utilities CUI.pdf | ||
| Rebid 2026 RFB EMS Station 12 Fencing.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
9 Fuel Tank !¹ Fuel Rectifier )p Fuel Pig Launch ô Fuel Pump Booster Station Ö Fuel Pump × Fuel Anode K Fuels Control Valve K Abandoned Fuels Control Valve Þ Fuel Filter Strainer æ High Pit ¿ Transition Pit
³Ü Hydrant Outlet Pit | Offloading, Truck e Offloading/Fillstand, Truck ' Abandoned Hydrant Outlet Pit
Defueling Line Fuels Installation Pipeline Abandoned Fuels Installation Pipeline u Natural Gas Storage Tank s Sewer Clean Out k Sewer Meter E Sewer Manhole E Abandoned Sewer Manhole K Sewer Control Valve K Abandoned Sewer Control Valve à Final Flume à Sewer Pump à Abandoned Sewer Pump n Sewer Oil Water Separator n Abandoned Sewer Oil Water Separator !w Sewer Outfall p Sewer Septic Tank i Sewer Grase Trap
Sewer Main Line Sewer Abandoned/Inactive Pipe Sewer Service Line Sewer Service Line Abandoned Sewer Force Main
")A Water Anode Test Station Water Control Valve Water Fitting
Q Water Hydrant W Water Meter < Water Pump Station ! Water Source « Water Fire Hydrant
Water Main Line Fire Main Line Hot Water Main Line Abandoned Water Main Line Water Service Line Fire Service Line Abandoned Water Service Line Water Storage Tank u Water Well
Sub-Basin Boundary C Stormwater Inlet
C Abandoned Stormwater Inlet ! StormWater Discharge Point
Stormwater Open Drainage Line Drainage Ditch Stormwater Gravity Line Service Stormwater Gravity Line Abandoned Stormwater Gravity Line Storm Culvert Gated Storm Culvert NonGated StormWater Storage Reservoir Zone1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6
Electric Layers
Fuel Layers
Natural Gas Layers
Stormwater LayersSewer Layers Water Layers
SJAFB Utility Layers Symbology
U:/2022 Base Map/Utility Maps
)Path Node Default
FODP
Splice Terminal
_̂ Service Loop AIP or Unknown Twisted Pair Fiber Coax Hybrid Fiber / Twisted Pair Hybrid Twisted Pair / Coax Hybrid Fiber / Coax Waveguide Bare / Ground Wire Tube Cable
Vacant InnerDuct In Service InnerDuct Vacant Duct In Service Duct Splice Container General Container Manhole Default Direct Buried Duct Ductbank
Thermal Layers
Communication Layers dR Electric Meter ³ Light Pole
Electrical Generator Ì Handhole  Junction Box c Manhole Ä Pedestal Sectionalizing Cubicle Ó Substation
!( Electrical Pole Ì Circuit Breaker ? Gang Disc Switch ÑC Pad Mounted Switch Ñ! Pole Mounted Switch
@C Pad Mounted, Circuit 1 @C Pad Mounted, Circuit 2 @C Pad Mounted, Circuit 3 @C Pad Mounted, Circuit 4 @C Pad Mounted, Circuit 5 #* Pole Mounted, Circuit 1 #* Pole Mounted, Circuit 2 #* Pole Mounted, Circuit 3
Overhead Transmission Line
ABANDONED
CIRCUIT 1
CIRCUIT 2
CIRCUIT 3
CIRCUIT 1
CIRCUIT 2
CIRCUIT 3
CIRCUIT 4
CIRCUIT 5
CIRCUIT 2
CIRCUIT 4
CIRCUIT 5
ñ Natural Gas Meter $ Natural Gas Valve u Natural Gas Storage Tank ö Natural Gas Reducer º Natural Gas Regulator
Gas Line Piedmont Gas Line Abandoned Gas Line u Heat Cool Junction Heat Cool Main Line Heat Cool Service Line
File details come from the government source that posted it. Updated .