Utility Legend Symbols.pdf

PDF 190 KB Posted

Attached to
Rebid RFB for EMS Station 12 Fencing
Solicitation number
471-04202026
Issued by
Warren County, North Carolina

About this file

This utility legend symbols document provides a comprehensive reference guide for interpreting utility infrastructure maps used by Wayne County and Seymour Johnson Air Force Base in North Carolina. The document categorizes utility symbols across multiple infrastructure layers including electric, fuel, natural gas, sewer, water, stormwater, thermal, and communication systems. Each symbol represents specific utility components such as meters, valves, pumps, storage tanks, pipe lines, and associated infrastructure features. The legend enables stakeholders to accurately read and interpret utility maps that depict the location and status of both active and abandoned utility systems across the service area.

The utility legend serves as a technical reference tool for the EMS Station 12 fencing project located at 2510 East Elm Street on Seymour Johnson Air Force Base in Goldsboro, North Carolina. Bidders responding to Wayne County's Request for Bids for fence removal and installation must use this symbology to understand existing utility infrastructure that may impact the project scope. The legend distinguishes between operational and abandoned utilities through visual differentiation and organizes symbols by utility type and function, allowing project teams to identify potential conflicts or considerations during fence work planning and execution. The document does not contain pricing information, set-asides, or contract terms but rather functions as a technical specification document necessary for accurate project planning and bidder understanding of site conditions.

View the file

Other files

File Type Posted
Perimeter Fence.pdf PDF
EMS STATION-Haul Route.pdf PDF
EMS Station Utilities CUI.pdf PDF
Rebid 2026 RFB EMS Station 12 Fencing.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

9 Fuel Tank !¹ Fuel Rectifier )p Fuel Pig Launch ô Fuel Pump Booster Station Ö Fuel Pump × Fuel Anode K Fuels Control Valve K Abandoned Fuels Control Valve Þ Fuel Filter Strainer æ High Pit ¿ Transition Pit

³Ü Hydrant Outlet Pit | Offloading, Truck e Offloading/Fillstand, Truck ' Abandoned Hydrant Outlet Pit

Defueling Line Fuels Installation Pipeline Abandoned Fuels Installation Pipeline u Natural Gas Storage Tank s Sewer Clean Out k Sewer Meter E Sewer Manhole E Abandoned Sewer Manhole K Sewer Control Valve K Abandoned Sewer Control Valve à Final Flume à Sewer Pump à Abandoned Sewer Pump n Sewer Oil Water Separator n Abandoned Sewer Oil Water Separator !w Sewer Outfall p Sewer Septic Tank i Sewer Grase Trap

Sewer Main Line Sewer Abandoned/Inactive Pipe Sewer Service Line Sewer Service Line Abandoned Sewer Force Main

")A Water Anode Test Station Water Control Valve Water Fitting

Q Water Hydrant W Water Meter < Water Pump Station ! Water Source « Water Fire Hydrant

Water Main Line Fire Main Line Hot Water Main Line Abandoned Water Main Line Water Service Line Fire Service Line Abandoned Water Service Line Water Storage Tank u Water Well

Sub-Basin Boundary C Stormwater Inlet

C Abandoned Stormwater Inlet ! StormWater Discharge Point

Stormwater Open Drainage Line Drainage Ditch Stormwater Gravity Line Service Stormwater Gravity Line Abandoned Stormwater Gravity Line Storm Culvert Gated Storm Culvert NonGated StormWater Storage Reservoir Zone1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6

Electric Layers

Fuel Layers

Natural Gas Layers

Stormwater LayersSewer Layers Water Layers

SJAFB Utility Layers Symbology

U:/2022 Base Map/Utility Maps

)Path Node Default

FODP

Splice Terminal

_̂ Service Loop AIP or Unknown Twisted Pair Fiber Coax Hybrid Fiber / Twisted Pair Hybrid Twisted Pair / Coax Hybrid Fiber / Coax Waveguide Bare / Ground Wire Tube Cable

Vacant InnerDuct In Service InnerDuct Vacant Duct In Service Duct Splice Container General Container Manhole Default Direct Buried Duct Ductbank

Thermal Layers

Communication Layers dR Electric Meter ³ Light Pole

Electrical Generator Ì Handhole  Junction Box c Manhole Ä Pedestal Sectionalizing Cubicle Ó Substation

!( Electrical Pole Ì Circuit Breaker ? Gang Disc Switch ÑC Pad Mounted Switch Ñ! Pole Mounted Switch

@C Pad Mounted, Circuit 1 @C Pad Mounted, Circuit 2 @C Pad Mounted, Circuit 3 @C Pad Mounted, Circuit 4 @C Pad Mounted, Circuit 5 #* Pole Mounted, Circuit 1 #* Pole Mounted, Circuit 2 #* Pole Mounted, Circuit 3

Overhead Transmission Line

ABANDONED

CIRCUIT 1

CIRCUIT 2

CIRCUIT 3

CIRCUIT 1

CIRCUIT 2

CIRCUIT 3

CIRCUIT 4

CIRCUIT 5

CIRCUIT 2

CIRCUIT 4

CIRCUIT 5

ñ Natural Gas Meter $ Natural Gas Valve u Natural Gas Storage Tank ö Natural Gas Reducer º Natural Gas Regulator

Gas Line Piedmont Gas Line Abandoned Gas Line u Heat Cool Junction Heat Cool Main Line Heat Cool Service Line

File details come from the government source that posted it. Updated .