UPS Maintenance - Attachment A~5.docx

DOCX document 520 KB Posted

Attached to
EMA - UPS Maintenance
Solicitation number
27-588IEMA-MGMTA-B-52893
Issued by
Illinois

About this file

This is a Scope of Work and pricing attachment for preventative maintenance and break/fix services for Uninterruptible Power Supply (UPS) units operated by the Illinois Emergency Management Agency and Office of Homeland Security (IEMA-OHS). IEMA-OHS operates seven Eaton UPS units across seven locations in Illinois: five units rated at 15kVA and two units rated at 30kVA, which provide critical backup power for the Gaseous Effluent Monitoring System (GEMS) at six nuclear power stations and one test facility in Springfield. The contract term is three years, from July 1, 2026, through June 30, 2029. Services required include annual preventative maintenance visits at each site, 24/7 on-site emergency response capability with a 30-minute callback requirement and four-hour on-site response time, and repair services with completion within 24 hours of problem diagnosis. All maintenance personnel must comply with Constellation nuclear power plant security requirements, including background reviews, urinalysis, and facility access clearance.

Vendors must submit pricing in four tables: Table A for annual preventative maintenance costs per site for each contract year; Table B for hourly service rates differentiated by time of day and day of week (Monday-Friday 8 AM-5 PM, Monday-Friday 5 PM-8 AM and Saturday, and Sunday/holidays); Table C for parts, materials, and equipment costs at percent off MSRP; and Table D for replacement battery costs including installation and disposal of spent batteries across the three contract years. All pricing must include travel, living expenses, and shipping costs. The contract is subject to the Illinois Prevailing Wage Act, requiring all contractors and subcontractors to pay workers no less than the prevailing wage rates established by the Illinois Department of Labor for the counties where work is performed. Vendors must maintain current knowledge of prevailing wage rates and ensure compliance throughout the contract term.

View the file

Other files

File Type Posted
standard-terms-and-conditions~41.pdf PDF
Standard Illinois Certifications v.26.2~3.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

IEMA-OHS UPS Maintenance

The Illinois Emergency Management Agency and Office of Homeland Security (IEMA-OHS) is seeking preventative maintenance and break/fix pricing for our agency Uninterruptable Power Supplies (UPS). IEMA-OHS has seven (7) Eaton UPS units. Five (5) are Eaton 9355-15 / 15KVA and two (2) are Eaton 9355-30 / 30KVA.

We are planning on a three-year term from July 1, 2026, through June 30, 2029.

OVERVIEW

In accordance with the Illinois Nuclear Safety Preparedness Act, the Illinois Emergency Management Agency and Office of Homeland Security is responsible for protecting the citizens of Illinois from potential adverse health effects from the use of radioactive material and radiation in the state. The Agency is specifically tasked with monitoring the commercial nuclear power stations in Illinois to detect releases of radioactive material. The Agency has highly sensitive monitoring equipment installed at each nuclear power station site that monitors gaseous effluents. The Gaseous Effluent Monitoring System (GEMS) monitors airborne effluents continuously by sampling mechanical handling systems, and a highly complex communications system to relay detailed isotopic analyses and system data to Agency scientists in Springfield. This data is monitored 24/7/365 as part of IEMA-OHS’ Remote Monitoring System.

To prevent loss of monitoring capability, each GEMS is equipped with backup emergency power systems consisting of a 50kW generator, a transfer switch system, and an uninterruptable power supply (UPS). The UPS is designed to activate immediately on loss of electrical power and carry the full electrical load of the GEMS while the emergency generator is ramping up to the appropriate speed. Once the generator reaches the appropriate speed, the transfer switch activates and immediately switches over from the UPS to the generator. In the event of generator failure, the UPS must be able to carry the full electrical load of the GEMS critical systems for at least four (4) hours; sufficient time for a technician to arrive on site to trouble shoot and repair the system. The UPS has filter circuitry to protect the GEMS and its sensitive components from power surges and failure in the event of blackout/brownout conditions. The UPS is an integral part of the GEMS operation and is installed at each of six (6) nuclear power stations in Illinois, within the high security protected area. IEMA also maintains a test bed system at our Springfield test facility that is identical to the fielded systems.

Units are located at the following locations:

Braidwood Generating Station (30kVa) 35100 S Route 53 Braceville, IL 60407-9619 Dresden (15kVa) 6500 N Dresden Rd.

Morris, IL 60450-9765 Illinois Emergency Mgmt. Agency and Office of Homeland Security (15kVa) 1301 Knotts St. (Rear Entrance) Springfield, IL 62703-5326

Byron (15kVa) 4450 N German Church Rd.

Byron, IL 61010-9794 LaSalle (30kVa) 2601 N 21st Rd.

Marseilles, IL 61341-9757

Clinton (15kVa) 8401 Power Rd.

Clinton, IL 61727-9182

Quad Cities (15kVa) 22710 – 206th Ave. North Cordova, IL 61242-9470

Mandatory Specifications:

M1: Vendor must provide annual major preventative maintenance visit per year, per site for the UPS. Vendor must be certified to perform repair and maintenance activities on this equipment. Vendor may be asked to provide documentation indicating their ability and authorization to resell and deliver products and services on behalf of the UPS manufacturer.

M2: Vendors and vendors’ agents involved with repair and maintenance must be willing to comply with Constellation nuclear power plant entry requirements, safety rules and regulations and procedures. These may include, and not be limited to, urinalysis, background review, escorted visitor/contractor requirements and vehicle search. Vendor must be cleared by Constellation for access to the protected areas of the power plant.

M3: Vendor must be able to provide 24/7 on site responses by an authorized/certified service engineer. Vendor will be notified of needed repairs via telephone and must call back within 30 minutes. Vendor must respond on site for system trouble resolution within four (4) hours (including weekends and holidays) of the vendor receiving notification of system problem or failure. Repairs will be expected within 24 hours of problem diagnosis. Repair service includes materials, parts replacement, and disposal of failed or expired batteries as needed. Vendor must prepare a written estimate and proposal of all repairs prior to servicing the device, including a description of work and a detailed breakdown of material, labor, and other costs.

M4: Vendor must use materials and equipment equivalent to those originally installed. Substitutions may only be used with prior IEMA-OHS consent. Vendor is to remove and properly dispose of all used or excess material, including, but not limited to, batteries, lubricant, filters, etc., as well as all waste products and debris. Disposal must be in accordance with prevailing federal, state, and local environmental regulations.

M5: Vendor must perform tests and adjustments with an approved testing procedure to establish performance levels for the system in accordance with the specifications. Vendor must follow the manufacturer’s commissioning, maintenance and service forms for every site call made.

M6: Vendor must perform an annual on-site inspection, performance of preventative maintenance and report of findings to IEMA-OHS for each UPS location. Preventative maintenance shall be scheduled on Agency’s availability during normal weekday work hours.

M7: Inspection and preventative maintenance must include, at a minimum: check wiring to confirm proper connections and locate any visual problems, visual inspection of internal subassemblies and major components, check mechanical connections, check ventilation systems and fan(s), check and clean all foreign material from interior of unit, inspect and test system alarms, verify all software system parameters and settings, perform all necessary calibrations in accordance with manufacturer recommendations, verify bypass/static switch, perform battery and inverter diagnostics, verify charger operation, run battery load test (when practical and upon approval of the Agency), perform detailed battery inspections with appropriate test equipment, perform/install any necessary field engineering modifications and upgrades, return unit to normal operation, log maintenance history into machine records, and remove and properly dispose of all waste products, and excess material and debris.

M8: Report findings must include, at a minimum: system location, model and serial numbers, date of service, start and end time of service, number of batteries, battery type, battery age, available run time and percentage of utilization, all inspections performed, and results found, all tests performed, and results found, all work performed, and comments regarding problems with the UPS and recommended solutions.

PRICING TABLES

Vendor must enter the cost in Pricing Table A for annual preventive maintenance on each of the UPS units listed below. Vendor must complete all required pricing fields to be deemed responsive.

PRICING TABLE A – Annual Preventive Maintenance

Description
Annual Preventive Maint.

7/1/2026 – 6/30/2027 Annual Preventive Maint.

7/1/2027 – 6/30/2028 Annual Preventive Maint.

7/1/2028 – 6/30/2029

Power Plant UPS

Braidwood (30kVA)

Byron (15kVA)

Clinton (15kVA)

Dresden (15kVA)

LaSalle (30kVA)

Quad Cities (15kVA)

IEMA UPS (Springfield, IL)

Knotts St. (15kVA)

TOTALS

Vendor must enter in Pricing Table B the hourly rate to be used for all service calls. Rates must be inclusive of all travel and living expenses. Vendor must complete all required pricing fields to be deemed responsive.

PRICING TABLE B – Service Calls

Service Description
Hourly Rate

07/01/2026 – 06/30/2027 Hourly Rate 07/01/2027 – 06/30/2028 Hourly Rate 07/01/2028 – 06/30/2029

Monday – Friday

(8:00 AM – 5:00 PM)

Monday – Friday

(5:00 PM – 8:00 AM)

and Saturday

Sunday and Holidays

For evaluation purposes only, the agency will use five (5) hours for Monday-Friday 8A-5P, two (2) hours for Monday-Friday 5P-8A/Saturday, and one (1) hour for Sunday in each of the twelve-month periods.

Vendor should include in Pricing Table C the cost for parts, materials, equipment or other items that IEMA may need during the course of this contract. This includes items that may be utilized during service calls. Rates must include all shipping and fees. Vendor may list percentage off MSRP in Pricing Table C if pricing is not known. Pricing in Table C will not be evaluated and will be used for contract purposes only.

Pricing Table C – Other Parts & Supplies

Description
Part Number
MSRP
% off MSRP (for contract term)
Total Price
Environmental Sensor
ENVIROSENSE
SNMP Web Card
SNMPWEBCARD

Other cards that potentially need replaced

Main Internal Fuses

Vendor must include in Pricing Table D the cost for replacement batteries for each of the UPS units listed below. Price must be inclusive of shipping to 1301 Knotts St., Springfield, IL. If the agency determines that battery replacement is necessary, the agency may elect to have the vendor provide the battery replacement and disposal of spent batteries.

Pricing Table D – Replacement Batteries

Description
Cost w/ Shipping

7/1/2026 – 6/30/2027 Cost w/ Shipping 7/1/2027 – 6/30/2028 Cost w/ Shipping 7/1/2028 – 6/30/2029

64 replacement batteries for Eaton 9355-15 / 15KVA PWHR1234W2FR (Knotts Street, Springfield)

256 replacement batteries for Eaton 9355-15 / 15KVA PWHR1234W2FR (GEMS Sites)

180 replacement batteries for Eaton 9355-30 / 20KVA NPX-L35FR (GEMS Sites)

Disposal of spent UPS batteries for each site

Installation by a field engineer for each site

CONTACT INFORMATION

Business Name

Address

City, State, Zip

Phone

Email

Contact

FEIN

This contract calls for the construction of a “public work,” within the meaning of the Illinois Prevailing Wage Act, 820 ILCS 130/.01 et seq. (the “Act”) or is a service contract subject to the prevailing wage requirements of the Illinois Procurement Code, 30ILCS 500/25-60 (the “Code”). The Act requires contractors and subcontractors to pay laborers, workers, and mechanics performing services on public works projects no less than the current “prevailing rate of wages” (hourly cash wages plus amount for fringe benefits) in the county where the work is performed. The Code requires vendors awarded certain service contracts to pay service workers no less than the general prevailing wage rate of hourly wages (hourly cash wages plus amount for fringe benefits) in the county where the work is performed. The Illinois Department of Labor publishes the prevailing wage rates on its website at http://labor.illinois.gov. The Illinois Department of Labor revises the prevailing wage rates, and the contractor / subcontractor has an obligation to check the Illinois Department of Labor’s web site for revisions to prevailing wage rates. For information regarding current prevailing wage rates, please refer to the Illinois Department of Labor’s website. All contractor and subcontractors rendering services under this contract must comply with all requirements image1.jpg image2.jpg image3.jpg