UFGS_09_90_00_Paints_and_Coatings_Base Facility Standards.pdf

PDF 255 KB Posted

Attached to
WPAFB Basewide Paint IDIQ Federal contract opportunity
Solicitation number
FA8601-20-R-0017
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Wright Patterson Air Force Base

View the file

Other files for this federal contract opportunity

Other files attached to WPAFB Basewide Paint IDIQ, newest first.
File Type Posted
Presolicitation Notice (RFP).pdf PDF
01 02 20_Base Facility Standards (Environmental).pdf PDF
Call Sheet_FBO.xlsx XLSX spreadsheet
Presolicitation Notice (RFP).pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

USACE / NAVFAC / AFCEC / NASA UFGS- 09 90 00 ( May 2011) Change 4 - 11/ 18 Pr epar i ng Act i v i t y: NAVFAC Super sedi ng UFGS- 09 90 00 ( August 2010)

UNI FI ED FACI LI TI ES GUI DE SPECI FI CATI ONS

Ref er ences ar e i n agr eement wi t h UMRL dat ed Oct ober 2019

SECTION TABLE OF CONTENTS

DIVISION 09 - FINISHES

SECTION 09 90 00

PAINTS AND COATINGS

05/11

PART 1 GENERAL

1.1 REFERENCES

1.2 SUBMITTALS

1.3 CERTIFICATES

1.3.1 Indoor Air Quality

1.3.1.1 Paints and Coatings

1.4 APPLICATOR'S QUALIFICATIONS

1.4.1 Contractor Qualification

1.4.2 SSPC QP 1 Certification

1.5 QUALITY ASSURANCE

1.5.1 Field Samples and Tests

1.5.1.1 Sampling Procedure

1.5.1.2 Testing Procedure

1.5.2 Textured Wall Coating System

1.5.3 Sample Textured Wall Coating System Mock-Up

1.6 REGULATORY REQUIREMENTS

1.6.1 Environmental Protection

1.6.2 Lead Content

1.6.3 Chromate Content

1.6.4 Asbestos Content

1.6.5 Mercury Content

1.6.6 Silica

1.6.7 Human Carcinogens

1.7 PACKAGING, LABELING, AND STORAGE

1.8 SAFETY AND HEALTH

1.8.1 Safety Methods Used During Coating Application

1.8.2 Toxic Materials

1.9 ENVIRONMENTAL CONDITIONS

1.9.1 Coatings

1.9.2 Post-Application

1.10 SCHEDULING

1.11 COLOR SELECTION

1.12 LOCATION AND SURFACE TYPE TO BE PAINTED

1.12.1 Painting Included

SECTION 09 90 00 Page 1

1.12.1.1 Exterior Painting

1.12.1.2 Interior Painting

1.12.2 Painting Excluded

1.12.3 Mechanical and Electrical Painting

1.12.3.1 Fire Extinguishing Sprinkler Systems

1.12.4 Exterior Painting of Site Work Items

1.12.5 MISCELLANEOUS PAINTING

1.12.6 Definitions and Abbreviations

1.12.6.1 Qualification Testing

1.12.6.2 Batch Quality Conformance Testing

1.12.6.3 Coating

1.12.6.4 DFT or dft

1.12.6.5 DSD

1.12.6.6 EPP

1.12.6.7 EXT

1.12.6.8 INT

1.12.6.9 micron / microns

1.12.6.10 mil / mils

1.12.6.11 mm

1.12.6.12 MPI Gloss Levels

1.12.6.13 MPI System Number

1.12.6.14 Paint

1.12.6.15 REX

1.12.6.16 RIN

PART 2 PRODUCTS

2.1 MATERIALS

PART 3 EXECUTION

3.1 PROTECTION OF AREAS AND SPACES NOT TO BE PAINTED

3.2 REPUTTYING AND REGLAZING

3.3 RESEALING OF EXISTING EXTERIOR JOINTS

3.3.1 Surface Condition

3.3.2 Backstops

3.3.3 Primer and Bond Breaker

3.3.4 Ambient Temperature

3.3.5 Exterior Sealant

3.3.6 Cleaning

3.4 SURFACE PREPARATION

3.4.1 Additional Requirements for Preparation of Surfaces With

Existing Coatings

3.4.2 Existing Coated Surfaces with Minor Defects

3.4.3 Removal of Existing Coatings

3.4.4 Substrate Repair

3.5 PREPARATION OF METAL SURFACES

3.5.1 Existing and New Ferrous Surfaces

3.5.2 Final Ferrous Surface Condition:

3.5.3 Galvanized Surfaces

3.5.4 Non-Ferrous Metallic Surfaces

3.5.5 Terne-Coated Metal Surfaces

3.5.6 Existing Surfaces with a Bituminous or Mastic-Type Coating

3.6 PREPARATION OF CONCRETE AND CEMENTITIOUS SURFACE

3.6.1 Concrete and Masonry

3.6.2 Gypsum Board, Plaster, and Stucco

3.6.3 Existing Asbestos Cement Surfaces

3.7 PREPARATION OF WOOD AND PLYWOOD SURFACES

3.7.1 New [, Existing Uncoated,] [and] [Existing Coated] Plywood and

SECTION 09 90 00 Page 2

Wood Surfaces, Except Floors:

3.7.2 Wood Floor Surfaces, Natural Finish

3.7.3 Interior Wood Surfaces, Stain Finish

3.7.4 Water Blasting of Existing Coated Wood Surfaces:

3.8 APPLICATION

3.8.1 Coating Application

3.8.2 Mixing and Thinning of Paints

3.8.3 Two-Component Systems

3.8.4 Coating Systems

3.9 COATING SYSTEMS FOR METAL

3.10 COATING SYSTEMS FOR CONCRETE AND CEMENTITIOUS SUBSTRATES

3.11 COATING SYSTEMS FOR WOOD AND PLYWOOD

3.12 PIPING IDENTIFICATION

3.13 INSPECTION AND ACCEPTANCE

3.14 WASTE MANAGEMENT

3.15 PAINT TABLES

3.15.1 Exterior Paint Tables

3.15.2 Interior Paint Tables

-- End of Section Table of Contents --

SECTION 09 90 00 Page 3

USACE / NAVFAC / AFCEC / NASA UFGS- 09 90 00 ( May 2011) Change 4 - 11/ 18 Pr epar i ng Act i v i t y: NAVFAC Super sedi ng UFGS- 09 90 00 ( August 2010)

UNI FI ED FACI LI TI ES GUI DE SPECI FI CATI ONS

Ref er ences ar e i n agr eement wi t h UMRL dat ed Oct ober 2019

SECTION 09 90 00

PAINTS AND COATINGS

05/11

NOTE: Thi s gui de speci f i cat i on cover s t he r equi r ement s f or pai nt i ng of new and exi st i ng, i nt er i or and ext er i or subst r at es, i ncl udi ng masonr y, concr et e, met al , wood and ot her mi scel l aneous materials.

Adher e t o UFC 1-300-02 Uni f i ed Faci l i t i es Gui de Speci f i cat i ons ( UFGS) For mat St andar d when edi t i ng t hi s gui de speci f i cat i on or pr epar i ng new pr oj ect speci f i cat i on sect i ons. Edi t t hi s gui de speci f i cat i on f or pr oj ect speci f i c r equi r ement s by addi ng, del et i ng, or r evi s i ng t ext . For br acket ed i t ems, choose appl i cabl e i t em( s) or i nser t appr opr i at e i nf or mat i on.

Remove i nf or mat i on and r equi r ement s not r equi r ed i n r espect i ve pr oj ect , whet her or not br acket s ar e present.

Comment s, suggest i ons and r ecommended changes f or t hi s gui de speci f i cat i on ar e wel come and shoul d be submi t t ed as a Criteria Change Request (CCR) .

NOTE: Thi s Gui de Speci f i cat i on i s used i n t he pr epar at i on of pr oj ect speci f i cat i ons f or Depar t ment of Def ense f aci l i t i es:

1. Bui l di ngs;

2. Rel at ed mechani cal , el ect r i cal , and mi scel l aneous i t ems; and

3. Shor e- t o- shi p ut i l i t y connect i ons.

Thi s gui de speci f i cat i on WAS NOT pr epar ed t o addr ess t he r equi r ement s of r out i ne mai nt enance pai nt i ng al t hough i t coul d be modi f i ed t o do so.

SECTION 09 90 00 Page 4

Thi s gui de speci f i cat i on DOES NOT addr ess hi gh- per f or mance or speci al t y coat i ng r equi r ement s, or pr ot ect i ve coat i ng of i ndust r i al st r uct ur es or f aci l i t i es, i ncl udi ng but not l i mi t ed t o:

1. Tower s;

2. Pi l i ngs;

3. Pavement mar ki ngs;

4. I t ems r equi r i ng speci al i zed t r eat ment due t o pecul i ar usage;

5. Pet r ol eum st or age f aci l i t i es;

6. Wat er st or age f aci l i t i es;

7. Wat er f r ont f aci l i t i es, except shor e- t o- shi p ut i l i t y connect i ons; and

8. Hangar s

I f such i t ems ar e i n t he pr oj ect i ncl ude i n a separ at e sect i on or modi f y t hi s sect i on accor di ngl y. The f ol l owi ng gui de speci f i cat i ons ar e exampl es of t hose avai l abl e f or speci f i c ser vi ce condi t i ons not ed, and may be modi f i ed t o pr ovi de f or r el at ed ser vi ce condi t i ons:

1. Sect i on 09 97 23 METALLI C TYPE CONDUCTI VE/ SPARK RESI STANT CONCRETE FLOOR FI NI SH. Thi s speci f i cat i on cover s t he pai nt i ng of hydr aul i c st r uct ur es l ocat ed i n f r esh wat er such as l ocks and dams.

2. Sect i on 09 97 13. 15 LOW VOC POLYSULFI DE I NTERI OR

COATI NG OF WELDED STEEL PETROLEUM FUEL TANKS

3. Sect i on 09 97 13. 27 EXTERI OR COATI NG OF STEEL STRUCTURES. Thi s speci f i cat i on i s usabl e f or any st eel st r uct ur e exposed t o weat her , and i s usabl e f or ot her pur poses as wel l , such as hangar st r uct ur es, encl osed swi mmi ng pool st r uct ur es, and most s i t uat i ons r equi r i ng hi gh- per f or mance pr ot ect i ve coat i ng syst ems.

4. Sect i on 09 97 13. 16 I NTERI OR COATI NG OF WELDED

STEEL WATER TANKS

5. Sect i on 09 97 13. 15 LOW VOC POLYSULFI DE I NTERI OR COATI NG OF WELDED STEEL PETROLEUM FUEL TANKS. Thi s i s a t hr ee- coat epoxy syst em t hat i s adapt abl e t o a wi de r ange of hi gh- per f or mance pr ot ect i ve coat i ng r equi r ement s wher e t her e i s no exposur e t o sunl i ght .

Thi s gui de gener al l y cont ai ns onl y t wo t ypes of coat i ng syst ems, sol vent based and wat er based. I f di f f er ent syst ems ar e r equi r ed r egi onal l y, or f or speci al needs, modi f y t he gui de accor di ngl y.

SECTION 09 90 00 Page 5

PART 1 GENERAL

1.1 REFERENCES

NOTE: Thi s par agr aph i s used t o l i s t t he publ i cat i ons c i t ed i n t he t ext of t he gui de speci f i cat i on. The publ i cat i ons ar e r ef er r ed t o i n t he t ext by basi c desi gnat i on onl y and l i s t ed i n t hi s par agr aph by or gani zat i on, desi gnat i on, dat e, and t i t l e.

Use t he Ref er ence Wi zar d' s Check Ref er ence f eat ur e when you add a Ref er ence I dent i f i er ( RI D) out si de of t he Sect i on' s Ref er ence Ar t i c l e t o aut omat i cal l y pl ace t he r ef er ence i n t he Ref er ence Ar t i c l e. Al so use t he Ref er ence Wi zar d' s Check Ref er ence f eat ur e t o updat e t he i ssue dat es.

Ref er ences not used i n t he t ext wi l l aut omat i cal l y be del et ed f r om t hi s sect i on of t he pr oj ect speci f i cat i on when you choose t o r econci l e r ef er ences i n t he publ i sh pr i nt pr ocess.

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN CONFERENCE OF GOVERNMENTAL INDUSTRIAL HYGIENISTS (ACGIH)

ACGIH 0100 (2015; Suppl 2002-2016) Documentation of the Threshold Limit Values and Biological Exposure Indices

ASME INTERNATIONAL (ASME)

ASME A13.1 (2015) Scheme for the Identification of Piping Systems

ASTM INTERNATIONAL (ASTM)

ASTM C920 (2018) Standard Specification for Elastomeric Joint Sealants

ASTM D235 (2002; R 2012) Mineral Spirits (Petroleum Spirits) (Hydrocarbon Dry Cleaning Solvent)

ASTM D523 (2014; R 2018) Standard Test Method for Specular Gloss

ASTM D2824/D2824M (2018) Standard Specification for Aluminum-Pigmented Asphalt Roof Coatings, Non-Fibered, and Fibered without Asbestos

ASTM D4214 (2007; R 2015) Standard Test Method for Evaluating the Degree of Chalking of

SECTION 09 90 00 Page 6

Exterior Paint Films

ASTM D4263 (1983; R 2018) Standard Test Method for Indicating Moisture in Concrete by the Plastic Sheet Method

ASTM D4444 (2013; R 2018) Standard Test Method for Laboratory Standardization and Calibration of Hand-Held Moisture Meters

ASTM D6386 (2016) Standard Practice for Preparation of Zinc (Hot-Dip Galvanized) Coated Iron and Steel Product and Hardware Surfaces for Painting

ASTM F1869 (2016) Standard Test Method for Measuring Moisture Vapor Emission Rate of Concrete Subfloor Using Anhydrous Calcium Chloride

MASTER PAINTERS INSTITUTE (MPI)

MPI 1 (2012) Aluminum Paint

MPI 2 (2012) Aluminum Heat Resistant Enamel (up to 427 C and 800 F

MPI 4 (2012) Interior/Exterior Latex Block Filler

MPI 5 (2012) Primer, Exterior Alkyd Wood

MPI 6 (2012) Primer, Exterior Latex Wood

MPI 7 (Oct 2009) Exterior Oil Wood Primer

MPI 8 (2012) Alkyd, Exterior Flat (MPI Gloss Level I)

MPI 9 (2012) Alkyd, Exterior Gloss (MPI Gloss Level 6)

MPI 10 (2012) Latex, Exterior Flat (MPI Gloss Level 1)

MPI 11 (2012) Latex, Exterior Semi-Gloss, MPI Gloss Level 5

MPI 13 (2012) Stain, Exterior Solvent-Based, Semi-Transparent

MPI 16 (2012) Stain, Exterior, Water Based, Solid Hide

MPI 19 (2012) Primer, Zinc Rich, Inorganic

MPI 21 (2012) Heat Resistant Coating, (Up to 205°C/402°F), MPI Gloss Level 6

MPI 22 (2012) Aluminum Paint, High Heat (up to 590° C/1100° F)

SECTION 09 90 00 Page 7

MPI 23 (2012) Primer, Metal, Surface Tolerant

MPI 26 (2012) Primer, Galvanized Metal, Cementitious

MPI 27 (2012) Floor Enamel, Alkyd, Gloss (MPI Gloss Level 6)

MPI 31 (2012) Varnish, Polyurethane, Moisture Cured, Gloss (MPI Gloss Level 6)

MPI 39 (2012) Primer, Latex, for Interior Wood

MPI 42 (2012) Textured Coating, Latex, Flat

MPI 44 (2012) Latex, Interior, (MPI Gloss Level 2)

MPI 45 (2012) Primer Sealer, Interior Alkyd

MPI 46 (2012) Undercoat, Enamel, Interior

MPI 47 (2012) Alkyd, Interior, Semi-Gloss (MPI Gloss Level 5)

MPI 48 (2012) Alkyd, Interior, Gloss (MPI Gloss Level 6-7)

MPI 49 (2012) Alkyd, Interior, Flat (MPI Gloss Level 1)

MPI 50 (2012) Primer Sealer, Latex, Interior

MPI 51 (2012) Alkyd, Interior, (MPI Gloss Level 3)2

MPI 52 (2012) Latex, Interior, (MPI Gloss Level 3)

MPI 54 (2012) Latex, Interior, Semi-Gloss (MPI Gloss Level 5)

MPI 56 (2012) Varnish, Interior, Polyurethane, Oil Modified, Gloss

MPI 57 (2012) Varnish, Interior, Polyurethane, Oil Modified, Satin

MPI 59 (2012) Floor Paint, Alkyd, Low Gloss

MPI 60 (2012) Floor Paint, Latex, Low Gloss

MPI 68 (2012) Floor Paint, Latex, Gloss

MPI 71 (2012) Varnish, Polyurethane, Moisture Cured, Flat (MPI Gloss Level 1)

MPI 72 (2012) Polyurethane, Two-Component, Pigmented, Gloss (MPI Gloss Level 6-7)

SECTION 09 90 00 Page 8

MPI 77 (2012) Epoxy, Gloss

MPI 79 (2012) Primer, Alkyd, Anti-Corrosive for Metal

MPI 90 (2012) Stain, Semi-Transparent, for Interior Wood

MPI 94 (2012) Alkyd, Exterior, Semi-Gloss (MPI Gloss Level 5)

MPI 95 (2012) Primer, Quick Dry, for Aluminum

MPI 101 (2012) Primer, Epoxy, Anti-Corrosive, for Metal

MPI 107 (2012) Primer, Rust-Inhibitive, Water Based

MPI 108 (2012) Epoxy, High Build, Low Gloss

MPI 113 (2012) Elastomeric, Pigmented, Exterior, Water Based, Flat

MPI 116 (2012) Block Filler, Epoxy

MPI 119 (2012) Latex, Exterior, Gloss (MPI Gloss Level 6)

MPI 134 (2012) Primer, Galvanized, Water Based

MPI 138 (2012) Latex, Interior, High Performance Architectural, (MPI Gloss Level 2)

MPI 139 (2012) Latex, Interior, High Performance Architectural, (MPI Gloss Level 3)

MPI 140 (2012) Latex, Interior, High Performance Architectural, (MPI Gloss Level 4)

MPI 141 (2012) Latex, Interior, High Performance Architectural, Semi-Gloss (MPI Gloss Level 5)

MPI 144 (2012) Latex, Interior, Institutional Low Odor/VOC, (MPI Gloss Level 2)

MPI 145 (2012) Latex, Interior, Institutional Low Odor/VOC, ( MPI Gloss Level 3)

MPI 146 (2012) Latex, Interior, Institutional Low Odor/VOC, (MPI Gloss Level 4)

MPI 147 (May 2016) Latex, Interior, Institutional Low Odor/VOC, Semi-Gloss (MPI Gloss Level 5)

MPI 151 (2012) Light Industrial Coating, Interior, Water Based (MPI Gloss Level 3)

SECTION 09 90 00 Page 9

MPI 153 (2012) Light Industrial Coating, Interior, Water Based, Semi-Gloss (MPI Gloss Level 5)

MPI 154 (2012) Light Industrial Coating, Interior, Water Based, Gloss (MPI Gloss Level 6)

MPI 161 (2012) Light Industrial Coating, Exterior, Water Based ( MPI Gloss Level 3)

MPI 163 (2012) Light Industrial Coating, Exterior, Water Based, Semi-Gloss (MPI Gloss Level 5)

MPI 164 (2012) Light Industrial Coating, Exterior, Water Based, Gloss (MPI Gloss Level 6)

SCIENTIFIC CERTIFICATION SYSTEMS (SCS)

SCS SCS Global Services (SCS) Indoor Advantage

SOCIETY FOR PROTECTIVE COATINGS (SSPC)

SSPC 7/NACE No.4 (2007; E 2004) Brush-Off Blast Cleaning

SSPC Guide 6 (2015) Guide for Containing Surface Preparation Debris Generated During Paint Removal Operations

SSPC Guide 7 (2004; E 2004) Guide to the Disposal of Lead-Contaminated Surface Preparation Debris

SSPC PA 1 (2016) Shop, Field, and Maintenance Coating of Metals

SSPC PA Guide 3 (1982; E 1995) A Guide to Safety in Paint Application

SSPC Paint 18 (1982; E 2004) Chlorinated Rubber Intermediate Coat Paint

SSPC QP 1 (2012; E 2012) Standard Procedure for Evaluating Painting Contractors (Field Application to Complex Industrial Structures)

SSPC SP 1 (2015) Solvent Cleaning

SSPC SP 2 (1982; E 2000; E 2004) Hand Tool Cleaning

SSPC SP 3 (1982; E 2004) Power Tool Cleaning

SSPC SP 6/NACE No.3 (2007) Commercial Blast Cleaning

SSPC SP 10/NACE No. 2 (2007) Near-White Blast Cleaning

SSPC SP 12/NACE No.5 (2002) Surface Preparation and Cleaning of Metals by Waterjetting Prior to Recoating

SECTION 09 90 00 Page 10

SSPC VIS 1 (2002; E 2004) Guide and Reference Photographs for Steel Surfaces Prepared by Dry Abrasive Blast Cleaning

SSPC VIS 3 (2004) Guide and Reference Photographs for Steel Surfaces Prepared by Hand and Power Tool Cleaning

SSPC VIS 4/NACE VIS 7 (1998; E 2000; E 2004) Guide and Reference Photographs for Steel Surfaces Prepared by Waterjetting

SOCIETY OF AUTOMOTIVE ENGINEERS INTERNATIONAL (SAE)

SAE AMS-STD-595A (2017) Colors used in Government Procurement

U.S. ARMY CORPS OF ENGINEERS (USACE)

EM 385-1-1 (2014) Safety and Health Requirements Manual

U.S. DEPARTMENT OF DEFENSE (DOD)

MIL-PRF-680 (2010; Rev C; Notice 1 2015) Degreasing Solvent

MIL-STD-101 (2014; Rev C) Color Code for Pipelines and for Compressed Gas Cylinders

U.S. ENVIRONMENTAL PROTECTION AGENCY (EPA)

EPA Method 24 (2000) Determination of Volatile Matter Content, Water Content, Density, Volume Solids, and Weight Solids of Surface Coatings

U.S. FEDERAL AVIATION ADMINISTRATION (FAA)

FAA AC 70/7460-1 (2015; Rev L) Obstruction Marking and Lighting

U.S. GENERAL SERVICES ADMINISTRATION (GSA)

FED-STD-313 (2014; Rev E) Material Safety Data, Transportation Data and Disposal Data for Hazardous Materials Furnished to Government Activities

U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)

29 CFR 1910.1000 Air Contaminants

29 CFR 1910.1001 Asbestos

29 CFR 1910.1025 Lead

29 CFR 1926.62 Lead

SECTION 09 90 00 Page 11

UNDERWRITERS LABORATORIES (UL)

UL 2818 (2013) GREENGUARD Certification Program For Chemical Emissions For Building Materials, Finishes And Furnishings

1.2 SUBMITTALS

NOTE: Revi ew Submi t t al Descr i pt i on ( SD) def i ni t i ons i n Sect i on 01 33 00 SUBMI TTAL PROCEDURES and edi t t he f ol l owi ng l i s t t o r ef l ect onl y t he submi t t al s r equi r ed f or t he pr oj ect .

The Gui de Speci f i cat i on t echni cal edi t or s have desi gnat ed t hose i t ems t hat r equi r e Gover nment appr oval , due t o t hei r compl exi t y or cr i t i cal i t y, wi t h a " G. " Gener al l y, ot her submi t t al i t ems can be r evi ewed by t he Cont r act or ' s Qual i t y Cont r ol Syst em. Onl y add a " G" t o an i t em, i f t he submi t t al i s suf f i c i ent l y i mpor t ant or compl ex i n cont ext of t he pr oj ect .

For submi t t al s r equi r i ng Gover nment appr oval on Ar my pr oj ect s, a code of up t o t hr ee char act er s wi t hi n t he submi t t al t ags may be used f ol l owi ng t he " G" desi gnat i on t o i ndi cat e t he appr ovi ng aut hor i t y.

Codes f or Ar my pr oj ect s usi ng t he Resi dent Management Syst em ( RMS) ar e: " AE" f or Ar chi t ect - Engi neer ; " DO" f or Di st r i ct Of f i ce ( Engi neer i ng Di v i s i on or ot her or gani zat i on i n t he Di st r i ct Of f i ce) ; " AO" f or Ar ea Of f i ce; " RO" f or Resi dent Of f i ce; and " PO" f or Pr oj ect Of f i ce. Codes f ol l owi ng t he " G" t ypi cal l y ar e not used f or Navy, Ai r For ce, and NASA pr oj ect s.

The " S" f ol l owi ng a submi t t al i t em i ndi cat es t hat t he submi t t al i s r equi r ed f or t he Sust ai nabi l i t y eNot ebook t o f ul f i l l f eder al l y mandat ed sust ai nabl e r equi r ement s i n accor dance wi t h Sect i on 01 33 29 SUSTAI NABI LI TY REPORTI NG. Locat e t he " S" submi t t al under t he SD number t hat best descr i bes t he submi t t al i t em.

Choose t he f i r st br acket ed i t em f or Navy, Ai r For ce and NASA pr oj ect s, or choose t he second br acket ed i t em f or Ar my pr oj ect s.

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are [for Contractor Quality Control approval.][for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government.] Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance with Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section

01 33 00 SUBMITTAL PROCEDURES:

The current MPI, "Approved Product List" which lists paint by brand, SECTION 09 90 00 Page 12 label, product name and product code as of the date of contract award, will be used to determine compliance with the submittal requirements of this specification. The Contractor may choose to use a subsequent MPI "Approved Product List", however, only one list may be used for the entire contract and each coating system is to be from a single manufacturer.

Provide all coats on a particular substrate from a single manufacturer.

No variation from the MPI Approved Products List is acceptable.

Samples of specified materials may be taken and tested for compliance with specification requirements.

SD-02 Shop Drawings

Piping Identification

SD-03 Product Data

Coating ; G[, [_____]]

Sealant

SD-04 Samples

Color ; G[, [_____]]

Textured Wall Coating System ; G[, [_____]]

[ Sample Textured Wall Coating System Mock-Up ; G[, [_____]]

] SD-07 Certificates

Applicator's Qualifications

Qualification Testing laboratory for coatings; G[, [_____]]

Indoor Air Quality for Paints and Primers

[ Indoor Air Quality for Consolidated Latex Paints

] SD-08 Manufacturer's Instructions

Application Instructions

Mixing

Manufacturer's Safety Data Sheets

SD-10 Operation and Maintenance Data

Coatings ; G[, [_____]]

1.3 CERTIFICATES

1.3.1 Indoor Air Quality

Submit required indoor air quality certifications in one submittal package.

SECTION 09 90 00 Page 13

1.3.1.1 Paints and Coatings

NOTE: The Gover nment s ' s pr ef er ence i s f or use of pr oduct s t hat have been cer t i f i ed f or i ndoor ai r qual i t y by a t hi r d- par t y or gani zat i on such as Gr eenguar d or SCS Gl obal Ser vi ces. Resear ch has shown t hat al l pai nt s except consol i dat ed l at ex pai nt s ar e avai l abl e among 3 nat i onal manuf act ur er s.

Ver i f y t her e i s a cer t i f i ed pr oduct avai l abl e when speci f y i ng consol i dat ed l at ex pai nt t hat i s bot h cost ef f ect i ve and appr opr i at e f or t he pr oj ect .

Conf i r m l ocal / r egi onal avai l abi l i t y of Gr eenguar d or SCS pr oduct s when speci f y i ng consol i dat ed l at ex pai nt t hat does not i mpact cost ef f ect i veness.

Provide paint and coating products certified to meet indoor air quality requirements by UL 2818 (Greenguard) Gold, SCS Global Services Indoor Advantage Gold or provide certification by other third-party programs.

Provide current product certification documentation from certification body.

1.4 APPLICATOR'S QUALIFICATIONS

NOTE: When usi ng t he cont r act or qual i f i cat i on c l ause r at her t han t he SSPC Cer t i f i cat i on r equi r ement s, edi t t o r equi r e appr opr i at e exper i ence.

NOTE: Sel ect onl y one of t he f ol l owi ng t wo br acket ed paragraphs.

[ 1.4.1 Contractor Qualification

Submit the name, address, telephone number, FAX number, and e-mail address of the contractor that will be performing all surface preparation and coating application. Submit evidence that key personnel have successfully performed surface preparation and application of coatings on [_____] on a minimum of three similar projects within the past three years. List information by individual and include the following:

a. Name of individual and proposed position for this work.

b. Information about each previous assignment including:

Position or responsibility

Employer (if other than the Contractor)

Name of facility owner

Mailing address, telephone number, and telex number (if non-US) of facility owner

Name of individual in facility owner's organization who can be

SECTION 09 90 00 Page 14 contacted as a reference

Location, size and description of structure

Dates work was carried out

Description of work carried out on structure

NOTE: For pr oj ect s i n cont i nent al US, Hawai i , Al aska, and Puer t o Ri co, r equi r e SSPC Cer t i f i cat i on. Use i n ot her l ocat i ons wher e qual i f i ed US cont r act or i s desi r ed. I f pr oj ect i nvol ves r emoval of pai nt cont ai ni ng hazar dous mat er i al s, add r equi r ement f or SSPC QP- 2 cer t i f i cat i on i n sect i on of speci f i cat i on wher e t he hazar dous pai nt r emoval i s speci f i ed, gener al l y Section 02 83 00 LEAD REMEDI ATI ON.

NOTE: * * WARNI NG* * WARNI NG* * WARNI NG* * WARNI NG* *

Sol i c i t at i ons r equi r i ng SSPC Cer t i f i cat i on shoul d poi nt out t he exi st ence and l ocat i on of t he cer t i f i cat i on r equi r ement , i n t he Pr oj ect I nf or mat i on For m. To be enf or ceabl e, i ncl ude t he r equi r ement i n t he sol i c i t at i on document s. SSPC Cer t i f i cat i on i s a speci al r esponsi bi l i t y r equi r ement pur suant t o FAR 9. 104- 2 Speci al St andar ds. Thi s i s anal ogous t o r equi r i ng bi dder s t o have a speci f i ed l evel of exper i ence or exper t i se and GAO has sust ai ned t hese t ypes of speci al requirements.

NOTE: Use br acket opt i on bel ow concer ni ng SSPC QP 1 onl y when i ndust r i al coat i ngs ar e r equi r ed.

Pai nt i ng qual i f i cat i ons f or pr oj ect s such as BEQ' s, t r ai ni ng f aci l i t i es and gener al admi ni st r at i on bui l di ngs do not r equi r e QP 1 cer t i f i cat i on.

[ 1.4.2 SSPC QP 1 Certification

All contractors and subcontractors that perform surface preparation or coating application must be certified by the Society for Protective Coatings (formerly Steel Structures Painting Council) (SSPC) to the requirements of SSPC QP 1 prior to contract award, and must remain certified while accomplishing any surface preparation or coating application. If a contractor's or subcontractor's certification expires, the firm will not be allowed to perform any work until the certification is reissued. Requests for extension of time for any delay to the completion of the project due to an inactive certification will not be considered and liquidated damages will apply. Notify the Contracting Officer of any change in contractor certification status.

SECTION 09 90 00 Page 15

] 1.5 QUALITY ASSURANCE

1.5.1 Field Samples and Tests

The Contracting Officer may choose up to two coatings that have been delivered to the site to be tested at no cost to the Government. Take samples of each chosen product as specified in the paragraph SAMPLING PROCEDURES. Test each chosen product as specified in the paragraph TESTING PROCEDURE. Remove products from the job site which do not conform, and replace with new products that conform to the referenced specification. Test replacement products that failed initial testing at no cost to the Government.

NOTE: Onl y r equi r e t he t est i ng f or l ar ge quant i t i es of epoxy/ pol yur et hane coat i ngs or a s i ngl e coat i ng syst em t hat i s used i n l ar ge quant i t i es on t he pr oj ect . A l ar ge quant i t y of epoxy/ pol yur et hane coat i ngs i s consi der ed t o be 189 Li t er s 50 gal l ons or mor e, a l ar ge quant i t y of ot her coat i ng syst ems i s consi der ed t o be 757 Li t er s 200 gal l ons or mor e.

Li st al l coat i ngs f or t est i ng by MPI or SSPC pai nt number i n t he f ol l owi ng par agr aph.

[ Another required testing is Batch Quality Conformance Testing to prove conformance of the manufacturer's paint to the specified MPI standard.

This testing is accomplished before the materials are delivered to the job site. Provide testing for [_____] paint products. Test paint products as specified in the paragraph "Testing Procedure".

] 1.5.1.1 Sampling Procedure

The Contracting Officer will select paint at random from the products that have been delivered to the job site for sample testing. The Contractor will provide one liter one quart samples of the selected paint materials.

Take samples in the presence of the Contracting Officer, and label, and identify each sample. Provide labels in accordance with the paragraph PACKAGING, LABELING, AND STORAGE of this specification.

1.5.1.2 Testing Procedure

Provide Batch Quality Conformance Testing for specified products, as defined by and performed by MPI. As an alternative to Batch Quality Conformance Testing, the Contractor may provide Qualification Testing for specified products above to the appropriate MPI product specification, using the third-party laboratory approved under the paragraph "Qualification Testing" laboratory for coatings. Include the backup data and summary of the test results within the qualification testing lab report. Provide a summary listing of all the reference specification requirements and the result of each test. Clearly indicate in the summary whether the tested paint meets each test requirement. Note that Qualification Testing may take 4 to 6 weeks to perform, due to the extent of testing required.

Submit name, address, telephone number, FAX number, and e-mail address of the independent third party laboratory selected to perform testing of coating samples for compliance with specification requirements. Submit documentation that laboratory is regularly engaged in testing of paint

SECTION 09 90 00 Page 16 samples for conformance with specifications, and that employees performing testing are qualified. If MPI is chosen to perform the Batch Quality Conformance testing, the above submittal information is not required, only a letter is required from the Contractor stating that MPI will perform the testing.

1.5.2 Textured Wall Coating System

Three complete samples of each indicated type, pattern, and color of textured wall coating system applied to a panel of the same material as that on which the coating system will be applied in the work. Provide samples of wall coating systems minimum 125 by 175 mm 5 by 7 inches and of sufficient size to show pattern repeat and texture.

NOTE: I ncl ude t he f ol l owi ng Mock- Up sect i on when a t ext ur ed wal l coat i ng syst em i s i ncl uded i n t he project.

[ 1.5.3 Sample Textured Wall Coating System Mock-Up

After coating samples are approved, and prior to starting installation, provide a minimum 2.43 m by 2.43 m 8 foot by 8 foot mock-up for each substrate and for each color and type of textured wall coating, using the actual substrate materials. Use the approved mock-up samples as a standard of workmanship for installation within the facility. Submit at least 48 hour advance written notice to the Contracting Officer's Representative prior to mock-up installation.

] 1.6 REGULATORY REQUIREMENTS

1.6.1 Environmental Protection

In addition to requirements specified elsewhere for environmental protection, provide coating materials that conform to the restrictions of the local Air Pollution Control District and regional jurisdiction.

Notify Contracting Officer of any paint specified herein which fails to conform.

1.6.2 Lead Content

Do not use coatings having a lead content over 0.06 percent by weight of nonvolatile content.

1.6.3 Chromate Content

Do not use coatings containing zinc-chromate or strontium-chromate.

1.6.4 Asbestos Content

Provide asbestos-free materials.

1.6.5 Mercury Content

Provide materials free of mercury or mercury compounds.

SECTION 09 90 00 Page 17

1.6.6 Silica

Provide abrasive blast media containing no free crystalline silica.

1.6.7 Human Carcinogens

Provide materials that do not contain ACGIH 0100 confirmed human carcinogens (A1) or suspected human carcinogens (A2).

1.7 PACKAGING, LABELING, AND STORAGE

NOTE: Mat er i al s wi t h a hi gh capaci t y t o absor b VOC emi ssi ons i ncl ude mat er i al s whi ch ar e woven, f i br ous or por ous i n nat ur e, such as acoust i cal cei l i ngs, car pet , and t ext i l es.

Provide paints in sealed containers that legibly show the contract specification number, designation name, formula or specification number, batch number, color, quantity, date of manufacture, manufacturer's formulation number, manufacturer's directions including any warnings and special precautions, and name and address of manufacturer. Furnish pigmented paints in containers not larger than 20 liters 5 gallons . Store paints and thinners in accordance with the manufacturer's written directions, and as a minimum, stored off the ground, under cover, with sufficient ventilation to prevent the buildup of flammable vapors, and at temperatures between 4 to 35 degrees C 40 to 95 degrees F . Do not store paint, polyurethane, varnish, or wood stain products with materials that have a high capacity to adsorb VOC emissions, [including [_____]]. Do not store paint, polyurethane, varnish, or wood stain products in occupied spaces.

1.8 SAFETY AND HEALTH

Apply coating materials using safety methods and equipment in accordance with the following:

Comply with applicable Federal, State, and local laws and regulations, and with the ACCIDENT PREVENTION PLAN, including the Activity Hazard Analysis as specified in Section 01 35 26 GOVERNMENT SAFETY REQUIREMENTS and in Appendix A of EM 385-1-1 . Include in the Activity Hazard Analysis the potential impact of painting operations on painting personnel and on others involved in and adjacent to the work zone.

1.8.1 Safety Methods Used During Coating Application

Comply with the requirements of SSPC PA Guide 3 .

1.8.2 Toxic Materials

To protect personnel from overexposure to toxic materials, conform to the most stringent guidance of:

a. The applicable manufacturer's Safety Data Sheets (SDS) or local regulation.

b. 29 CFR 1910.1000 .

SECTION 09 90 00 Page 18

c. ACGIH 0100 , threshold limit values.

NOTE: Del et e f ol l owi ng par agr aph i f no l ead i s cont ai ned i n exi st i ng coat i ng syst ems.

[ d. The appropriate OSHA standard in 29 CFR 1910.1025 and 29 CFR 1926.62 for surface preparation on painted surfaces containing lead. Removal and disposal of coatings which contain lead is specified in Section 02 83 00 LEAD REMEDIATION[_____]. Additional guidance is given in SSPC Guide 6 and SSPC Guide 7 . Refer to drawings for list of hazardous materials located on this project. Coordinate paint preparation activities with this specification section.

NOTE: Del et e f ol l owi ng par agr aph i f no asbest os i s cont ai ned i n exi st i ng coat i ng syst ems.

[ e. The appropriate OSHA standards in 29 CFR 1910.1001 for surface preparation of painted surfaces containing asbestos. Removal and disposal of coatings which contain asbestos materials is specified in Section 02 82 00 ASBESTOS REMEDIATION. Refer to drawings for list of hazardous materials located on this project. Coordinate paint preparation activities with this specification section.

] Submit manufacturer's Safety Data Sheets for coatings, solvents, and other potentially hazardous materials, as defined in FED-STD-313 .

1.9 ENVIRONMENTAL CONDITIONS

Comply, at minimum, with manufacturer recommendations for space ventilation during and after installation.[ Isolate area of application from rest of building when applying high-emission paints or coatings.]

1.9.1 Coatings

Do not apply coating when air or substrate conditions are:

a. Less than 3 degrees C 5 degrees F above dew point;

b. Below 10 degrees C 50 degrees F or over 35 degrees C 95 degrees F , unless specifically pre-approved by the Contracting Officer and the product manufacturer. Do not, under any circumstances, violate the manufacturer's application recommendations.

1.9.2 Post-Application

NOTE: Choose t he most appr opr i at e opt i on( s) f or vent i l at i on. For i nst ance, hi gh- humi di t y r egi ons may gener at e t oo much condensat e when usi ng 100 per cent out si de ai r .

Vacate space for as long as possible after application. Wait a minimum of 48 hours before occupying freshly painted rooms. Maintain one of the following ventilation conditions during the curing period, or for 72 hours

SECTION 09 90 00 Page 19 after application:

a. Supply 100 percent outside air 24 hours a day.

b. Supply airflow at a rate of 6 air changes per hour, when outside temperatures are between 13 degrees C 55 degrees F and 29 degrees C 85 degrees F and humidity is between 30 percent and 60 percent.

c. Supply airflow at a rate of 1.5 air changes per hour, when outside air conditions are not within the range stipulated above.

1.10 SCHEDULING

NOTE: Mat er i al s t hat adsor b VOCs i ncl ude car pet s, t ext i l es, unpr i med gypsum wal l boar d, and acoust i cal cei l i ng panel s.

Allow paint, polyurethane, varnish, and wood stain installations to cure prior to the installation of materials that adsorb VOCs, including [_____].

1.11 COLOR SELECTION

NOTE: I ncl ude t he f ol l owi ng br acket ed par agr aph and Tabl e i f t he pr oj ect i ncl udes pai nt i ng of Shor e- To- Shi p Ut i l i t y connect i ons

[ Color Coding For Shore-To-Ship Utility Connections: Paint hose connection fittings and shut-off valves the designated color. In addition to color coding provide 50 mm 2 inch high stenciled letters using black stencil paint, clearly designating service for each connection.

Color Coding for Shore-to-Ship Utility Connections

Service Color SAE AMS-STD-595A No.

Potable Water* Blue 15044

Water Provided Red 11105 for Fire Protection**

Chilled Water Striped Blue/White 15044/17886

Oily Waste Water Striped Yellow/Black 13538/17038

Sewer Gold 17043

Steam White 17886

High Pressure Air Gray 16081

Low Pressure Air Tan 10324

Fuel Yellow 13655

SECTION 09 90 00 Page 20

Color Coding for Shore-to-Ship Utility Connections

Service Color SAE AMS-STD-595A No.

* This includes connections serving domestic functions.

** This includes non-potable salt water or, at some locations, fresh water connections provided for fire protection (may also include flushing and cooling requirements). Note: This does not include waterfront fire hydrants.

] Provide colors of finish coats as indicated or specified. Allow Contracting Officer to select colors not indicated or specified.

Manufacturers' names and color identification are used for the purpose of color identification only. Named products are acceptable for use only if they conform to specified requirements. Products of other manufacturers are acceptable if the colors approximate colors indicated and the product conforms to specified requirements.

Tint each coat progressively darker to enable confirmation of the number of coats.

NOTE: On Navy pr oj ect s, do not use Sect i on 09 06 00 SCHEDULES FOR FI NI SHES. Pr ovi de col or sel ect i on on t he cont r act dr awi ngs.

Provide color, texture, and pattern of wall coating systems [as indicated][in accordance with Section 09 06 00 SCHEDULES FOR FINISHES]

Submit manufacturer's samples of paint colors. Cross reference color samples to color scheme as indicated. Submit color stencil codes.

1.12 LOCATION AND SURFACE TYPE TO BE PAINTED

NOTE: Dr awi ngs shoul d i ndi cat e t ype and ext ent of wor k. Speci f i c quant i t i es shoul d not be ci t ed i n t he speci f i cat i on. I ndi cat e on t he dr awi ngs t he l i near amount of exi st i ng put t y, gl azi ng compound, seal ant or caul k i ng t o be r epl aced wi t h new mat er i al and quant i f y t he ar ea of exi st i ng coat i ng t o be r emoved by met hods speci f i ed f or each subst r at e material.

1.12.1 Painting Included

Where a space or surface is indicated to be painted, include the following unless indicated otherwise.

a. Surfaces behind portable objects and surface mounted articles readily detachable by removal of fasteners, such as screws and bolts.

b. New factory finished surfaces that require identification or color coding and factory finished surfaces that are damaged during

SECTION 09 90 00 Page 21 performance of the work.

c. Existing coated surfaces that are damaged during performance of the work.

1.12.1.1 Exterior Painting

Includes new surfaces[, existing coated surfaces,] [and] [existing uncoated surfaces,] of the building[s] and appurtenances. Also included are existing coated surfaces made bare by cleaning operations.

1.12.1.2 Interior Painting

Includes new surfaces[, existing uncoated surfaces,] [and] [existing coated surfaces] of the building[s] and appurtenances as indicated and existing coated surfaces made bare by cleaning operations. Where a space or surface is indicated to be painted, include the following items, unless indicated otherwise.

a. Exposed columns, girders, beams, joists, and metal deck; and

b. Other contiguous surfaces.

1.12.2 Painting Excluded

Do not paint the following unless indicated otherwise.

a. Surfaces concealed and made inaccessible by panelboards, fixed ductwork, machinery, and equipment fixed in place.

b. Surfaces in concealed spaces. Concealed spaces are defined as enclosed spaces above suspended ceilings, furred spaces, attic spaces, crawl spaces, elevator shafts and chases.

c. Steel to be embedded in concrete.

d. Copper, stainless steel, aluminum, brass, and lead except existing coated surfaces.

e. Hardware, fittings, and other factory finished items.

[ f. Do not paint surfaces in the following areas: [_____].

] 1.12.3 Mechanical and Electrical Painting

Includes field coating of [interior] [and] [exterior] new [and existing] surfaces.

a. Where a space or surface is indicated to be painted, include the following items unless indicated otherwise.

(1) Exposed piping, conduit, and ductwork;

(2) Supports, hangers, air grilles, and registers;

(3) Miscellaneous metalwork and insulation coverings.

[ b. Do not paint the following, unless indicated otherwise:

SECTION 09 90 00 Page 22

[ (1) New zinc-coated, aluminum, and copper surfaces under insulation

][ (2) New aluminum jacket on piping

][ (3) New interior ferrous piping under insulation.

]][ 1.12.3.1 Fire Extinguishing Sprinkler Systems

Clean, pretreat, prime, and paint new fire extinguishing sprinkler systems including valves, piping, conduit, hangers, supports, miscellaneous metalwork, and accessories. Apply coatings to clean, dry surfaces, using clean brushes. Clean the surfaces to remove dust, dirt, rust, and loose mill scale. Immediately after cleaning, provide the metal surfaces with one coat primer per schedules. Shield sprinkler heads with protective covering while painting is in progress. Upon completion of painting, remove protective covering from sprinkler heads. Remove sprinkler heads which have been painted and replace with new sprinkler heads. Provide primed surfaces with the following:

a. Piping in Unfinished Areas: Provide primed surfaces with one coat of red alkyd gloss enamel applied to a minimum dry film thickness of

0.025 mm 1.0 mil in attic spaces, spaces above suspended ceilings, crawl spaces, pipe chases, mechanical equipment room, and spaces where walls or ceiling are not painted or not constructed of a prefinished material.[ In lieu of red enamel finish coat, provide piping with 50 mm 2 inch wide red enamel bands or self-adhering red plastic bands spaced at maximum of 6 meters 20 foot intervals.]

b. Piping in Finished Areas: Provide primed surfaces with two coats of paint to match adjacent surfaces, except provide valves and operating accessories with one coat of red alkyd gloss enamel applied to a minimum dry film thickness of 0.025 mm 1.0 mil . Provide piping with 50 mm 2 inch wide red enamel bands or self-adhering red plastic bands spaced at maximum of 6 meters 20 foot intervals throughout the piping systems.

] [ 1.12.4 Exterior Painting of Site Work Items

Field coat the following items:

New Surfaces Existing Surfaces

a. [_____] [_____]

b. [_____] [_____]

c. [_____] [_____]

] 1.12.5 MISCELLANEOUS PAINTING

Lettering [Building ][Room Number(s) ]

Provide lettering [as scheduled on the drawings] [block] [Gothic] type, [black enamel] [water-type decalcomania, finished with a protective coating of spar varnish]. Samples must be approved before application.

[ Obstructions To Aviation

SECTION 09 90 00 Page 23

NOTE: St r uct ur es, such as smokest acks, pol es, and bui l di ngs, whi ch have been i dent i f i ed as obst r uct i on t o avi at i on wi l l be speci f i ed by name. Ver i f y t hat t he st r uct ur es so i dent i f i ed ar e not speci f i ed t o be pai nt ed i n t he sect i ons speci f y i ng t he st r uct ur es so t hat pai nt i ng wi l l not be speci f i ed t wi ce.

Coor di nat e wi t h FAA f or al t er nat e col or s and pat t er ns.

Paint the following obstructions to aviation in the pattern and color prescribed by FAA AC 70/7460-1 : [_____]

] 1.12.6 Definitions and Abbreviations

1.12.6.1 Qualification Testing

Qualification testing is the performance of all test requirements listed in the product specification. This testing is accomplished by MPI to qualify each product for the MPI Approved Product List, and may also be accomplished by Contractor's third party testing lab if an alternative to Batch Quality Conformance Testing by MPI is desired.

1.12.6.2 Batch Quality Conformance Testing

Batch quality conformance testing determines that the product provided is the same as the product qualified to the appropriate product specification. This testing must be accomplished by an MPI testing lab.

1.12.6.3 Coating

A film or thin layer applied to a base material called a substrate. A coating may be a metal, alloy, paint, or solid/liquid suspensions on various substrates (such as metals, plastics, wood, paper, leather, cloth). They may be applied by electrolysis, vapor deposition, vacuum, or mechanical means such as brushing, spraying, calendaring, and roller coating. A coating may be applied for aesthetic or protective purposes or both. The term "coating" as used herein includes emulsions, enamels, stains, varnishes, sealers, epoxies, and other coatings, whether used as primer, intermediate, or finish coat. The terms paint and coating are used interchangeably.

1.12.6.4 DFT or dft

Dry film thickness, the film thickness of the fully cured, dry paint or coating.

1.12.6.5 DSD

Degree of Surface Degradation, the MPI system of defining degree of surface degradation. Five (5) levels are generically defined under the Assessment sections in the MPI Maintenance Repainting Manual.

1.12.6.6 EPP

Environmentally Preferred Products, a standard for determining environmental preferability in support of Executive Order 13101.

SECTION 09 90 00 Page 24

1.12.6.7 EXT

MPI short term designation for an exterior coating system.

1.12.6.8 INT

MPI short term designation for an interior coating system.

1.12.6.9 micron / microns

The metric measurement for 0.001 mm or one/one-thousandth of a millimeter.

1.12.6.10 mil / mils

The English measurement for 0.001 in or one/one-thousandth of an inch, equal to 25.4 microns or 0.0254 mm.

1.12.6.11 mm

The metric measurement for millimeter, 0.001 meter or one/one-thousandth of a meter.

1.12.6.12 MPI Gloss Levels

MPI system of defining gloss. Seven (7) gloss levels (G1 to G7) are generically defined under the Evaluation sections of the MPI Manuals.

Traditionally, Flat refers to G1/G2, Eggshell refers to G3, Semigloss refers to G5, and Gloss refers to G6.

Gloss levels are defined by MPI as follows:

Gloss Description Units Units Level at 60 degrees at 85 degrees

G1 Matte or Flat 0 to 5 10 max G2 Velvet 0 to 10 10 to 35 G3 Eggshell 10 to 25 10 to 35 G4 Satin 20 to 35 35 min G5 Semi-Gloss 35 to 70 G6 Gloss 70 to 85 G7 High Gloss

Gloss is tested in accordance with ASTM D523. Historically, the Government has used Flat (G1 / G2), Eggshell (G3), Semi-Gloss (G5), and Gloss (G6).

1.12.6.13 MPI System Number

The MPI coating system number in each Division found in either the MPI Architectural Painting Specification Manual or the Maintenance Repainting Manual and defined as an exterior (EXT/REX) or interior system (INT/RIN).

The Division number follows the CSI Master Format.

1.12.6.14 Paint

See Coating definition.

SECTION 09 90 00 Page 25

1.12.6.15 REX

MPI short term designation for an exterior coating system used in repainting projects or over existing coating systems.

1.12.6.16 RIN

MPI short term designation for an interior coating system used in repainting projects or over existing coating systems.

PART 2 PRODUCTS

2.1 MATERIALS

NOTE: Repr ocessed and consol i dat ed l at ex pai nt s ar e EPA desi gnat ed pr oduct s. Ver i f y t he avai l abi l i t y of cer t i f i ed pr oduct s wi t hi n t he r egi on when speci f y i ng consol i dat ed l at ex pai nt .

Conform to the coating specifications and standards referenced in PART 3.

Submit product data sheets for specified coatings and solvents. Provide preprinted cleaning and maintenance instructions for all coating systems.

Submit Manufacturer's Instructions on Mixing: Detailed mixing instructions, minimum and maximum application temperature and humidity, potlife, and curing and drying times between coats.

Provide certification of Indoor Air Quality for paints and primers .

[ Provide certification of Indoor Air Quality for consolidated latex paints .

] PART 3 EXECUTION

NOTE: Exer ci se caut i on when devi at i ng f r om pai nt syst ems l i s t ed i n t abl es of " PART 3 EXECUTI ON. " Ver i f y compat i bi l i t y and sui t abi l i t y of pai nt syst ems subst i t ut ed by r evi ewi ng t he Eval uat i on of Syst ems sect i ons of t he MPI Manual s.

3.1 PROTECTION OF AREAS AND SPACES NOT TO BE PAINTED

Prior to surface preparation and coating applications, remove, mask, or otherwise protect hardware, hardware accessories, machined surfaces, radiator covers, plates, lighting fixtures, public and private property, and other such items not to be coated that are in contact with surfaces to be coated. Following completion of painting, reinstall removed items by workmen skilled in the trades. Restore surfaces contaminated by coating materials, to original condition and repair damaged items.

[ 3.2 REPUTTYING AND REGLAZING

NOTE: I ncl ude t hi s par agr aph ( 3. 2) onl y f or pr oj ect s i nvol v i ng pai nt i ng of exi st i ng wi ndows but not i ncl udi ng a gl azi ng sect i on. Reput t y i ng wor k

SECTION 09 90 00 Page 26 shoul d be cover ed i n gl azi ng sect i on i f such a sect i on i s used i n t he pr oj ect speci f i cat i ons. Thi s i s nor mal l y used i n hi st or i cal pr eser vat i on. Avoi d usi ng l i nseed oi l put t y at bui l di ng i nt er i or .

Remove cracked, loose, and defective putty or glazing compound on glazed sash and provide new putty or glazing compound. Where defective putty or glazing compound constitutes 30 percent or more of the putty at any one light, remove the glass and putty or glazing compound and reset the glass.

Remove putty or glazing compound without damaging sash or glass. Clean rabbets to bare wood or metal and prime prior to reglazing. Provide linseed oil putty for wood sash. Patch surfaces to provide smooth transition between existing and new surfaces. Finish putty or glazing compound to a neat and true bead. Allow glazing compound time to cure, in accordance with manufacturer's recommendation, prior to coating application. Allow putty to set one week prior to coating application.

][ 3.3 RESEALING OF EXISTING EXTERIOR JOINTS

NOTE: I ncl ude t hi s par agr aph ( 3. 3) onl y f or pr oj ect s i nvol v i ng r eseal i ng of exi st i ng ext er i or j oi nt s but not i ncl udi ng a seal ant sect i on 07 92 00 JOI NT SEALANTS. Such wor k shoul d be cover ed i n seal ant sect i on i f such a sect i on i s used i n t he pr oj ect speci f i cat i ons.

3.3.1 Surface Condition

Begin with surfaces that are clean, dry to the touch, and free from frost and moisture; remove grease, oil, wax, lacquer, paint, defective backstop, or other foreign matter that would prevent or impair adhesion.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .