TUIN_231534_FINAL_CD_PLANS_1_OF_4_BASE_BID_compr_1.pdf

PDF 22 MB Posted

Attached to
TUIN 213534 Preserve Carver Museum
Solicitation number
DOIPFBO220067
Issued by

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TPF

TPF

TPF

TPF

TPF

TP

F

TP

F

TPFTPF

SS

SS

SS

SS

SS

SS

SS

UNIVERSITY AVENUE

X

X

X

X

X

X X

SCALE: 1" = 20'

0 20' 40' 60'10'

SS

SS

SS

SS

SS

UNIVERSITY AVENUE

X

X

X

X

X X

SCALE: 1" = 20'

0 20' 40' 60'10'

SS

SS

SS

SS

SS

SS

SS

SS

SS

X

X

X

X

X

X

X X

X

X

X

X

X

X

X

X

SCALE: 1" = 10'

0 5' 30'20'10'

STORM LINE A PROFILE

1" = 10'-0"

STORM LINE B PROFILE

1" = 10'-0"

STORM LINE C PROFILE

1" = 10'-0"

STORM LINE D PROFILE

1" = 10'-0"

STORM LINE E PROFILE

1" = 10'-0"

STORM LINE F PROFILE

1" = 10'-0"

LOD

LOC

TREE PROTECTION FENCE: HIGH

DENSITY POLYETHYLENE FENCING

WITH 3.5" X 1.5" OPENINGS; COLOR-

ORANGE. WOOD STAKES INSTALLED

AT 8' O.C.

KEEP OUT

TREE

PROTECTION

AREA

8.5" X 11" SIGN LAMINATED

IN PLASTIC SPACED EVERY

50' ALONG THE FENCE

4' -0

CROWN DRIP LINE OR OTHER LIMIT OF TREE PROTECTION AREA.

SEE TREE PRESERVATION PLAN FOR FENCE ALIGNMENT.

MAINTAIN EXISTING GRADE WITH

THE TREE PROTECTION FENCE

UNLESS OTHERWISE INDICATED

ON THE PLANS.

NOTES:

1. SEE GENERAL NOTES FOR ADDITIONAL TREE

PROTECTION REQUIREMENTS.

2. IF THERE IS NO EXISTING IRRIGATION, SEE

SPECIFICATIONS FOR WATERING

REQUIREMENTS.

3. NO PRUNING SHALL BE PERFORMED EXCEPT BY

APPROVED ARBORIST.

4. NO EQUIPMENT SHALL OPERATE INSIDE THE

PROTECTIVE FENCING INCLUDING DURING

FENCE INSTALLATION AND REMOVAL.

WOOD STAKES

OR APPROVED EQUAL.

UNIVERSITY AVENUE

TPF

TPF

TPF

TPF

TPF

TPF

TPF

TP

F

TPFTPF

LO

C

LO

C

LO

C

LOC

LOC

LOC

LOC

LO

C

LOC

LOC

LOC

LO

C

LO

C

LO

C

LO

C

LOC

LOC

LOC LOC

LOC

LOC

LO

C

LOD

LO

D

LO

D

LO

D

LO

D

LO

D

LO

D

LO

D

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOD

LOC

UNIVERSITY AVENUE

LO

C

LO

C

LO

C

LOC

LOC

LOC

LOC

LO

C

LOC

LOC

LOC

LO

C

LO

C

LO

C

LO

C

LOC

LOC

LOC LOC

LOC

LOC

LO

C

LOD

LO

D

LO

D

LO

D

LO

D

LO

D

LO

D

LOD

LOD

LOD

LOD

LOD

LOD

LOD

(7)

KALMIA LATIFOLIA

(5)

ILEX VOMITORIA `NANA`

(3)

SPIRAEA THUNBERGII

(1,518 sf)

CYNODON DACTYLON

VINCA MINOR

(170)

ILEX VOMITORIA `NANA`

(27)

(1)

FORSYTHIA X INTERMEDIA

(1)

LAGERSTROEMIA X `NATCHEZ`

(160 sf)

SEED MIX NATIVE

(37 sf)

CYNODON DACTYLON

(221 sf)

CYNODON DACTYLON

CYNODON DACTYLON

(151 sf)

FORSYTHIA X INTERMEDIA

(1)

THUJA OCCIDENTALIS 'LITTLE GIANT'

(2)

SPIRAEA THUNBERGII

(4)

THUJA OCCIDENTALIS 'LITTLE GIANT'

(4)

FORSYTHIA X INTERMEDIA

(2)

VINCA MINOR

(209)

TREES QTY BOTANICAL / COMMON NAME CONT

1 LAGERSTROEMIA X `NATCHEZ` / CRAPE MYRTLE 2.5" CAL.

SHRUBS QTY BOTANICAL / COMMON NAME SIZE

4 FORSYTHIA X INTERMEDIA / BORDER FORSYTHIA 5 GAL

32 ILEX VOMITORIA `NANA` / DWARF YAUPON 3 GAL

7 KALMIA LATIFOLIA / MOUNTAIN LAUREL 5 GAL

7 SPIRAEA THUNBERGII / THUNBERG SPIREA 3 GAL

1 STEWARTIA MALACODENDRON / SILKY CAMELLIA 5 GAL

6 THUJA OCCIDENTALIS 'LITTLE GIANT' / LITTLE GIANT ARBORVITAE 3 GAL

GROUND COVERS QTY BOTANICAL / COMMON NAME CONT SPACING

1,927 SF CYNODON DACTYLON / BERMUDA GRASS SOD

379 VINCA MINOR / COMMON PERIWINKLE 4" POT 12" o.c.

SEED MIX QTY BOTANICAL / COMMON NAME CONT SPACING

160 SF SEED MIX NATIVE / NATIVE SEED MIX SEED

PLANT SCHEDULE

(1)

STEWARTIA MALACODENDRONRIVER ROCK

SEE CIVIL DETAILS

SEE SPEC 32 93 00

(180 SF)

PLAN VIEW OF STAKING

COMPACTED SOIL PEDESTAL

12" TYP. FINAL HGT. TBD IN FIELD

TO PROMOTE PROPER DRAINAGE

REBAR STAKE

#5, 36" LENGTH, DRIVE TO FINISH

GRADE OR BELOW

ALT: 2"x2"x36" WOOD STAKE

ARBORKNOT OR APPROVED

EQUAL. TIED TO MANUF. SPEC.

WHITE FLAGGING, ALL GUYS

MULCH RING, MIN. 3" DEPTH

DO NOT PILE MULCH AGAINST TREE

ARBORTIE GREEN GUYING

MATERIAL, OR APPROVED EQUAL

SOIL BERM TO HOLD WATER

FERTILIZER TABLETS,

SEE SPECIFICATIONS

SCARIFY SIDE OF PLANTING HOLE,

MIN. 4" DEPTH

REMOVE BURLAP AND ROPE FROM TOP 13 OF

ROOTBALL, ALL NON-BIODEGRADABLE MATERIAL TO

BE REMOVED, CUT THREE 12" DEEP VERTICAL CUTS EQ.

SPACED AROUND ROOTBALL TO PROMOTE GROWTH

SUBGRADE

2X ROOTBALL

AMENDED SOIL AS NEEDED PER

SPECIFICATIONS

NOTES:

1. TREE ROOT BALL SET FLUSH WITH FINISHED GRADE UNLESS SITE DETERMINED TO HAVE POOR DRAINAGE, IN WHICH CASE PLANT ROOT BALL 2"

ABOVE FINISH GRADE.

2. PLUMB TREE BEFORE STAKING.

3. LOCATE ARBORTIE ABOVE FIRST SCAFFOLD BRANCHES. FOR MULTI-TRUNKED TREES, ATTACHED TO LARGEST TRUNK.

4. REMOVE ALL BRANCHES THAT ARE DAMAGED, RUBBING, OR CROSSING OTHER BRANCHES.

5. MAINTAIN CENTRAL LEADER IN TACT

6. FINAL TREE PLACEMENT TO BE APPROVED BY CONTRACTING OFFICER.

7. SPACE STAKES EVENLY AROUND OUTSIDE OF PLANTING PIT.

8. CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION.

9. REMOVE ARBORTIE AND STAKES AFTER ONE FULL GROWING SEASON, OR UNLESS OTHERWISE SPECIFIED.

10. FILL TREE PIT WITH WATER AND CONFIRM PERCOLATION RATE PRIOR TO PLANTING. NOTIFY LANDSCAPE IF POOR DRAINAGE EXISTS.

COMPACTED SOIL FILL

FERTILIZER TABLETS,

SEE SPECIFICATIONS

SCARIFY SIDE OF PLANTING HOLE,

AND ROOT BALL

SUBGRADE

AMENDED SOIL AS NEEDED PER

SPECIFICATIONS

NOTES:

1. SHRUB ROOT BALL SET 2" ABOVE FINISHED GRADE

2. PLUMB SHRUB BEFORE STAKING.

3. CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION.

4. ENSURE ALL AIR POCKETS ARE REMOVED WHILE BACKFILLING SOIL MIXTURE.

5. UNLESS OTHERWISE SPECIFIED, STAGGER ROWS OF SHRUBS.

MULCH OVER ENTIRE BED,

4" COVERAGE, MAX. 1" DEEP ON

TOP OF ROOT BALL, SEE SPEC.

FOR MULCH

FINISH GRADE

LOOSEN SUBGRADE AND REMOVE

IMPERVIOUS DEBRIS

SHRUB SET 2" ABOVE EXISTING

GRADE

EQ.EQ.

NOTES:

1. SEE PLANTING LEGEND FOR GROUNDCOVER SPECIES, SIZE, AND SPACING DIMENSION.

2. SMALL ROOTS (14" OR LESS) THAT GROW AROUND, UP, OR DOWN THE ROOT BALL PERIPHERY

ARE CONSIDERED A NORMAL CONDITION IN CONTAINER PRODUCTION AND ARE ACCEPTABLE

HOWEVER THEY SHOULD BE ELIMINATED AT THE TIME OF PLANTING. ROOTS ON THE PERIPHERY

CAN BE REMOVED AT THE TIME OF PLANTING.

3. SETTLE SOIL AROUND ROOT BALL OF EACH GROUNDCOVER PRIOR TO MULCHING.

PLAN

SECTION VIEW

6" M

IN

GROUNDCOVER PLANTS TO BE

TRIANGULARLY SPACED

MULCH

ADJACENT HARDSCAPE

3" THICK LAYER OF MULCH

FINISHED GRADE

MODIFIED SOIL. DEPTH VARIES

EXISTING SOIL

O.C. SPACING

O.

C.

S

PA

CI

NG

18" MIN. SETBACK FOR SHRUBS FROM

12" MIN. SETBACK FOR GROUNDCOVERS

NOTE:

1. THE PERIMETER OF ALL CURVED PLANTING

BEDS SHALL BE PLANTED WITH A ROW OF

SHRUBS AS SHOWN IN THE PLANS AND AT

THE SPACING SHOWN IN THE PLANT LIST.

INTERIOR PORTIONS OF EACH BED SHALL BE

PLANTED AT APPROPRIATE SPACING

ACCORDING TO THIS PLANT SPACING DETAIL.

2. BEST FACE OF EACH PLANT SHALL FACE

FRONT OF PLANTING BED.

CURB / EDGE OF PAVEMENT/ BED LINE

18" MIN. FOR SHRUBS

12" MIN. FOR GROUNDCOVERS

ALL SHRUBS/GROUNDCOVER TO

BE TRIANGULAR SPACED WHERE

MASSED. SEE PLANT LIST FOR

(O.C.) SPACING

BED LINE

COMPACTED SOIL FILL

FERTILIZER TABLETS,

SEE SPECIFICATIONS

SCARIFY SIDE OF PLANTING HOLE,

AND ROOT BALL

SUBGRADE

AMENDED SOIL AS NEEDED PER

SPECIFICATIONS

NOTES:

1. SHRUB ROOT BALL SET FLUSH WITH FINISHED GRADE

2. WHEN SHRUBS ARE PLANTED IN MASSING, DO NOT FORM SOIL BERMS ON INDIVIDUAL PLANTS AND ENTIRE PLANTING BED SHALL BE EXCAVATED TO RECEIVE PLANTING SOIL AND PLANT MATERIAL.

3. PLUM SHRUB BEFORE STAKING.

4. CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION.

5. ENSURE ALL AIR POCKETS ARE REMOVED WHILE BACKFILLING SOIL MIXTURE.

6. UNLESS OTHERWISE SPECIFIED, STAGGER ROWS OF SHRUBS.

MULCH OVER ENTIRE BED,

4" COVERAGE, MAX. 1" DEEP ON

TOP OF ROOT BALL, SEE SPEC.

FOR MULCH

FINISH GRADE

LOOSEN SUBGRADE AND REMOVE

IMPERVIOUS DEBRIS

SOIL BERM TO HOLD WATER

CUT BACK SLOPE TO PROVIDE A

FLAT SURFACE FOR PLANTING

TUIN_FINALCD_GEN
COVER
PLOT
G1.0
PLOT
G1.1
PLOT
G1.2
PLOT
G1.3
PLOT
G1.4
PLOT
G2.0
PLOT
G3.0
PLOT
G3.1
PLOT

TUIN_FINALCD_BASEBID

File details come from the government source that posted it. Updated .