TUIN_231534_FINAL_CD_PLANS_1_OF_4_BASE_BID_compr_1.pdf
PDF 22 MB Posted
- Attached to
- TUIN 213534 Preserve Carver Museum
- Solicitation number
- DOIPFBO220067
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TPF
TPF
TPF
TPF
TPF
TP
F
TP
F
TPFTPF
SS
SS
SS
SS
SS
SS
SS
UNIVERSITY AVENUE
X
X
X
X
X
X X
SCALE: 1" = 20'
0 20' 40' 60'10'
SS
SS
SS
SS
SS
UNIVERSITY AVENUE
X
X
X
X
X X
SCALE: 1" = 20'
0 20' 40' 60'10'
SS
SS
SS
SS
SS
SS
SS
SS
SS
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
SCALE: 1" = 10'
0 5' 30'20'10'
STORM LINE A PROFILE
1" = 10'-0"
STORM LINE B PROFILE
1" = 10'-0"
STORM LINE C PROFILE
1" = 10'-0"
STORM LINE D PROFILE
1" = 10'-0"
STORM LINE E PROFILE
1" = 10'-0"
STORM LINE F PROFILE
1" = 10'-0"
LOD
LOC
TREE PROTECTION FENCE: HIGH
DENSITY POLYETHYLENE FENCING
WITH 3.5" X 1.5" OPENINGS; COLOR-
ORANGE. WOOD STAKES INSTALLED
AT 8' O.C.
KEEP OUT
TREE
PROTECTION
AREA
8.5" X 11" SIGN LAMINATED
IN PLASTIC SPACED EVERY
50' ALONG THE FENCE
4' -0
CROWN DRIP LINE OR OTHER LIMIT OF TREE PROTECTION AREA.
SEE TREE PRESERVATION PLAN FOR FENCE ALIGNMENT.
MAINTAIN EXISTING GRADE WITH
THE TREE PROTECTION FENCE
UNLESS OTHERWISE INDICATED
ON THE PLANS.
NOTES:
1. SEE GENERAL NOTES FOR ADDITIONAL TREE
PROTECTION REQUIREMENTS.
2. IF THERE IS NO EXISTING IRRIGATION, SEE
SPECIFICATIONS FOR WATERING
REQUIREMENTS.
3. NO PRUNING SHALL BE PERFORMED EXCEPT BY
APPROVED ARBORIST.
4. NO EQUIPMENT SHALL OPERATE INSIDE THE
PROTECTIVE FENCING INCLUDING DURING
FENCE INSTALLATION AND REMOVAL.
WOOD STAKES
OR APPROVED EQUAL.
UNIVERSITY AVENUE
TPF
TPF
TPF
TPF
TPF
TPF
TPF
TP
F
TPFTPF
LO
C
LO
C
LO
C
LOC
LOC
LOC
LOC
LO
C
LOC
LOC
LOC
LO
C
LO
C
LO
C
LO
C
LOC
LOC
LOC LOC
LOC
LOC
LO
C
LOD
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOC
UNIVERSITY AVENUE
LO
C
LO
C
LO
C
LOC
LOC
LOC
LOC
LO
C
LOC
LOC
LOC
LO
C
LO
C
LO
C
LO
C
LOC
LOC
LOC LOC
LOC
LOC
LO
C
LOD
LO
D
LO
D
LO
D
LO
D
LO
D
LO
D
LOD
LOD
LOD
LOD
LOD
LOD
LOD
(7)
KALMIA LATIFOLIA
(5)
ILEX VOMITORIA `NANA`
(3)
SPIRAEA THUNBERGII
(1,518 sf)
CYNODON DACTYLON
VINCA MINOR
(170)
ILEX VOMITORIA `NANA`
(27)
(1)
FORSYTHIA X INTERMEDIA
(1)
LAGERSTROEMIA X `NATCHEZ`
(160 sf)
SEED MIX NATIVE
(37 sf)
CYNODON DACTYLON
(221 sf)
CYNODON DACTYLON
CYNODON DACTYLON
(151 sf)
FORSYTHIA X INTERMEDIA
(1)
THUJA OCCIDENTALIS 'LITTLE GIANT'
(2)
SPIRAEA THUNBERGII
(4)
THUJA OCCIDENTALIS 'LITTLE GIANT'
(4)
FORSYTHIA X INTERMEDIA
(2)
VINCA MINOR
(209)
TREES QTY BOTANICAL / COMMON NAME CONT
1 LAGERSTROEMIA X `NATCHEZ` / CRAPE MYRTLE 2.5" CAL.
SHRUBS QTY BOTANICAL / COMMON NAME SIZE
4 FORSYTHIA X INTERMEDIA / BORDER FORSYTHIA 5 GAL
32 ILEX VOMITORIA `NANA` / DWARF YAUPON 3 GAL
7 KALMIA LATIFOLIA / MOUNTAIN LAUREL 5 GAL
7 SPIRAEA THUNBERGII / THUNBERG SPIREA 3 GAL
1 STEWARTIA MALACODENDRON / SILKY CAMELLIA 5 GAL
6 THUJA OCCIDENTALIS 'LITTLE GIANT' / LITTLE GIANT ARBORVITAE 3 GAL
GROUND COVERS QTY BOTANICAL / COMMON NAME CONT SPACING
1,927 SF CYNODON DACTYLON / BERMUDA GRASS SOD
379 VINCA MINOR / COMMON PERIWINKLE 4" POT 12" o.c.
SEED MIX QTY BOTANICAL / COMMON NAME CONT SPACING
160 SF SEED MIX NATIVE / NATIVE SEED MIX SEED
PLANT SCHEDULE
(1)
STEWARTIA MALACODENDRONRIVER ROCK
SEE CIVIL DETAILS
SEE SPEC 32 93 00
(180 SF)
PLAN VIEW OF STAKING
COMPACTED SOIL PEDESTAL
12" TYP. FINAL HGT. TBD IN FIELD
TO PROMOTE PROPER DRAINAGE
REBAR STAKE
#5, 36" LENGTH, DRIVE TO FINISH
GRADE OR BELOW
ALT: 2"x2"x36" WOOD STAKE
ARBORKNOT OR APPROVED
EQUAL. TIED TO MANUF. SPEC.
WHITE FLAGGING, ALL GUYS
MULCH RING, MIN. 3" DEPTH
DO NOT PILE MULCH AGAINST TREE
ARBORTIE GREEN GUYING
MATERIAL, OR APPROVED EQUAL
SOIL BERM TO HOLD WATER
FERTILIZER TABLETS,
SEE SPECIFICATIONS
SCARIFY SIDE OF PLANTING HOLE,
MIN. 4" DEPTH
REMOVE BURLAP AND ROPE FROM TOP 13 OF
ROOTBALL, ALL NON-BIODEGRADABLE MATERIAL TO
BE REMOVED, CUT THREE 12" DEEP VERTICAL CUTS EQ.
SPACED AROUND ROOTBALL TO PROMOTE GROWTH
SUBGRADE
2X ROOTBALL
AMENDED SOIL AS NEEDED PER
SPECIFICATIONS
NOTES:
1. TREE ROOT BALL SET FLUSH WITH FINISHED GRADE UNLESS SITE DETERMINED TO HAVE POOR DRAINAGE, IN WHICH CASE PLANT ROOT BALL 2"
ABOVE FINISH GRADE.
2. PLUMB TREE BEFORE STAKING.
3. LOCATE ARBORTIE ABOVE FIRST SCAFFOLD BRANCHES. FOR MULTI-TRUNKED TREES, ATTACHED TO LARGEST TRUNK.
4. REMOVE ALL BRANCHES THAT ARE DAMAGED, RUBBING, OR CROSSING OTHER BRANCHES.
5. MAINTAIN CENTRAL LEADER IN TACT
6. FINAL TREE PLACEMENT TO BE APPROVED BY CONTRACTING OFFICER.
7. SPACE STAKES EVENLY AROUND OUTSIDE OF PLANTING PIT.
8. CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION.
9. REMOVE ARBORTIE AND STAKES AFTER ONE FULL GROWING SEASON, OR UNLESS OTHERWISE SPECIFIED.
10. FILL TREE PIT WITH WATER AND CONFIRM PERCOLATION RATE PRIOR TO PLANTING. NOTIFY LANDSCAPE IF POOR DRAINAGE EXISTS.
COMPACTED SOIL FILL
FERTILIZER TABLETS,
SEE SPECIFICATIONS
SCARIFY SIDE OF PLANTING HOLE,
AND ROOT BALL
SUBGRADE
AMENDED SOIL AS NEEDED PER
SPECIFICATIONS
NOTES:
1. SHRUB ROOT BALL SET 2" ABOVE FINISHED GRADE
2. PLUMB SHRUB BEFORE STAKING.
3. CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION.
4. ENSURE ALL AIR POCKETS ARE REMOVED WHILE BACKFILLING SOIL MIXTURE.
5. UNLESS OTHERWISE SPECIFIED, STAGGER ROWS OF SHRUBS.
MULCH OVER ENTIRE BED,
4" COVERAGE, MAX. 1" DEEP ON
TOP OF ROOT BALL, SEE SPEC.
FOR MULCH
FINISH GRADE
LOOSEN SUBGRADE AND REMOVE
IMPERVIOUS DEBRIS
SHRUB SET 2" ABOVE EXISTING
GRADE
EQ.EQ.
NOTES:
1. SEE PLANTING LEGEND FOR GROUNDCOVER SPECIES, SIZE, AND SPACING DIMENSION.
2. SMALL ROOTS (14" OR LESS) THAT GROW AROUND, UP, OR DOWN THE ROOT BALL PERIPHERY
ARE CONSIDERED A NORMAL CONDITION IN CONTAINER PRODUCTION AND ARE ACCEPTABLE
HOWEVER THEY SHOULD BE ELIMINATED AT THE TIME OF PLANTING. ROOTS ON THE PERIPHERY
CAN BE REMOVED AT THE TIME OF PLANTING.
3. SETTLE SOIL AROUND ROOT BALL OF EACH GROUNDCOVER PRIOR TO MULCHING.
PLAN
SECTION VIEW
6" M
IN
GROUNDCOVER PLANTS TO BE
TRIANGULARLY SPACED
MULCH
ADJACENT HARDSCAPE
3" THICK LAYER OF MULCH
FINISHED GRADE
MODIFIED SOIL. DEPTH VARIES
EXISTING SOIL
O.C. SPACING
O.
C.
S
PA
CI
NG
18" MIN. SETBACK FOR SHRUBS FROM
12" MIN. SETBACK FOR GROUNDCOVERS
NOTE:
1. THE PERIMETER OF ALL CURVED PLANTING
BEDS SHALL BE PLANTED WITH A ROW OF
SHRUBS AS SHOWN IN THE PLANS AND AT
THE SPACING SHOWN IN THE PLANT LIST.
INTERIOR PORTIONS OF EACH BED SHALL BE
PLANTED AT APPROPRIATE SPACING
ACCORDING TO THIS PLANT SPACING DETAIL.
2. BEST FACE OF EACH PLANT SHALL FACE
FRONT OF PLANTING BED.
CURB / EDGE OF PAVEMENT/ BED LINE
18" MIN. FOR SHRUBS
12" MIN. FOR GROUNDCOVERS
ALL SHRUBS/GROUNDCOVER TO
BE TRIANGULAR SPACED WHERE
MASSED. SEE PLANT LIST FOR
(O.C.) SPACING
BED LINE
COMPACTED SOIL FILL
FERTILIZER TABLETS,
SEE SPECIFICATIONS
SCARIFY SIDE OF PLANTING HOLE,
AND ROOT BALL
SUBGRADE
AMENDED SOIL AS NEEDED PER
SPECIFICATIONS
NOTES:
1. SHRUB ROOT BALL SET FLUSH WITH FINISHED GRADE
2. WHEN SHRUBS ARE PLANTED IN MASSING, DO NOT FORM SOIL BERMS ON INDIVIDUAL PLANTS AND ENTIRE PLANTING BED SHALL BE EXCAVATED TO RECEIVE PLANTING SOIL AND PLANT MATERIAL.
3. PLUM SHRUB BEFORE STAKING.
4. CONTRACTOR SHALL ASSURE PERCOLATION OF ALL PLANTING PITS PRIOR TO INSTALLATION.
5. ENSURE ALL AIR POCKETS ARE REMOVED WHILE BACKFILLING SOIL MIXTURE.
6. UNLESS OTHERWISE SPECIFIED, STAGGER ROWS OF SHRUBS.
MULCH OVER ENTIRE BED,
4" COVERAGE, MAX. 1" DEEP ON
TOP OF ROOT BALL, SEE SPEC.
FOR MULCH
FINISH GRADE
LOOSEN SUBGRADE AND REMOVE
IMPERVIOUS DEBRIS
SOIL BERM TO HOLD WATER
CUT BACK SLOPE TO PROVIDE A
FLAT SURFACE FOR PLANTING
| TUIN_FINALCD_GEN |
| COVER |
| PLOT |
| G1.0 |
| PLOT |
| G1.1 |
| PLOT |
| G1.2 |
| PLOT |
| G1.3 |
| PLOT |
| G1.4 |
| PLOT |
| G2.0 |
| PLOT |
| G3.0 |
| PLOT |
| G3.1 |
| PLOT |
TUIN_FINALCD_BASEBID
File details come from the government source that posted it. Updated .