TP Camera Drawings.pdf
PDF 9 MB Posted
- Solicitation number
- RFP PPS 260000002113 5
- Issued by
- Kalamazoo County, Michigan
About this file
This document comprises technical design drawings and specifications for a security camera installation project at Woodland Elementary School in Portage, Michigan, submitted by Portage Public Schools. The project scope includes the installation of security cameras, mounting hardware, and camera licenses for an existing video management system (VMS) across the school's first floor, divided into three units (A, B, and C). The camera schedule specifies 16 total cameras: 2 ceiling-mounted cameras (model PND-A9081RV) and 14 exterior wall and corner-mounted cameras (model PNM-C32083RVQ) installed at 10 feet elevation. The design was issued for bidding on November 22, 2024, with a bulletin update dated April 16, 2026. The project includes detailed specifications for camera placement, mounting hardware, labeling requirements, cabling infrastructure, and integration with the owner's network and recording systems.
Installation requirements mandate that work be completed by or overseen by a manufacturer-certified professional, with cameras configured according to the owner's network standards and recording specifications. The scope explicitly excludes camera cabling, network video recorders (NVRs), and the VMS, which are already provided. All cameras require security labeling visible from ground level, weathertight sealant and surge suppression for exterior units, and safety wire securing ceiling-mounted cameras to the structure above. Contractors must coordinate with the owner on IP address assignment, device naming conventions, initial camera aiming, and final sign-off on all camera views through a camera coordination spreadsheet prior to configuration of recording parameters and analytics settings.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L
L R
IG
H
T S
R E
S E
R V
E D
DESIGN TEAM
ARCHITECT/ENGINEER
WOODLAND ELEMENTARY SCHOOL -
SECURITY CAMERAS
PORTAGE PUBLIC SCHOOLS
Portage, Michigan
C O
V E
R S
H E
E T
-2
.5
G
.5
W O
O D
L A
N D
E L E
M E
N T
A R
Y S
C H
O O
L
S E
C U
R
IT
Y C
A M
E R
A S
P o rt a g e
M ic h ig a n
P O
R T
A G
E P
U B
L
IC
S C
H O
O L
S
N O
V E
M B
E R
BID DOCUMENTS
DRAWING INDEX
PORTAGE PUBLIC SCHOOLS
1401 WOODLAND DR.
PORTAGE, MI 49024
242 E. KALAMAZOO AVE, SUITE 100
KALAMAZOO, MICHIGAN 49007
PHONE: 269.343.6133
FAX: 269.343.6633
SITE ADDRESS
ISSUED FOR DATE
TECHNOLOGY - GENERAL
TG 001.54 TECHNOLOGY SYMBOLS AND GENERAL NOTES
TECHNOLOGY
T 101.54A FIRST FLOOR TECHNOLOGY PLAN - UNIT A
T 101.54B FIRST FLOOR TECHNOLOGY PLAN - UNIT B
T 101.54C FIRST FLOOR TECHNOLOGY PLAN - UNIT C
T 441.54 CAMERA DETAILS
RELEASE BUTTON
CARD READER - 4 SQ BOX, SG COVER, 3/4" CONDUIT STUB
KEY PAD - 4 SQ BOX, SG COVER, 3/4" CONDUIT STUB
INTERCOM - 4 SQ BOX, SG COVER, 3/4" CONDUIT STUB 40"
40"
40"
SECURITY CAMERA - WALL
SECURITY CAMERA - CEILING
SECURITY CABLING PATHWAY, 4 SQ, SG BRUSH PLATE, 1" CONDUIT STUB
INTERCOM MASTER STATION
LOCKDOWN BUTTON
DURESS ALARM PUSH BUTTON - UNDER DESK
ACCESS CONTROL DETAIL INDICATOR: REFER TO ACCESS
CONTROL DETAILS AND SCHEDULE
16"
ACCESS CONTROL PANEL (REFER TO DETAILS)
CARD READER, MULLION MOUNT, 3/4" CONDUIT STUB 40"
LOCKDOWN STROBE (REFER TO DETAILS)
SECURITY SYMBOLS
RB
CR
KP
IC
SCP
MS
LD
DA
#n
ACP #
CR
M
LS
NOTES:
MOUNT DEVICES AT HEIGHTS INDICATED UNLESS INDICATED
OTHERWISE ON PLANS. HEIGHTS ARE TO BOTTOM OF DEVICE.
DB
ST
DOORBELL, 4 SQ BOX, SG REDUCER, 3/4" CONDUIT STUB
DOORBELL STROBE, 4 SQ BOX, SG REDUCER, 3/4"C STUB
40"
96"
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L
L R
IG
H
T S
R E
S E
R V
E D
T E
C H
N O
L O
G Y
S Y
M B
O L
S A
N D
G E
N E
R A
L N
O T
E S
-2
.5
T G
.5
W O
O D
L A
N D
E L E
M E
N T
A R
Y S
C H
O O
L
S E
C U
R
IT
Y C
A M
E R
A S
P o rt a g e
M ic h ig a n
P O
R T
A G
E P
U B
L
IC
S C
H O
O L
S
N O
V E
M B
E R
ISSUED FOR DATE
GENERAL NOTES - SECURITY CAMERA
1 INSTALLATION SHALL BE COMPLETED BY OR OVERSEEN BY A MANUFACTURER CERTIFIED
PROFESSIONAL.
2 INSTALL CAMERAS USING ALL APPROPRIATE HANGERS, FASTENERS, ETC. CAMERAS
INSTALLED IN GRID/LAY IN CEILING SHALL HAVE SAFETY WIRE TYING THE CAMERA TO
STRUCTURE ABOVE. EXTERIOR CAMERAS SHALL HAVE WEATHERTIGHT SEALANT AND
SURGE SUPPRESSION INSTALLED. REFER TO CAMERA ROUGH IN DETAILS.
3 PRIOR TO CONNECTION TO OWNER'S NETWORK, DEFAULT USERNAME AND PASSWORD
SHALL BE CHANGED. COORDINATE WITH OWNER FOR DEVICE SPECIFIC USERNAMES
AND PASSWORDS.
4 CAMERA SHALL BE CONFIGURED BASED ON OWNER'S NETWORK CONFIGURATION AND
NAMING STANDARDS. COMPLETE AN IP ADDRESS REQUEST WITH THE OWNER,
COORDINATE NAMING CONFIGURATION BASED ON CAMERA COORDINATION
SPREADSHEET.
5 INSTALL CAMERAS WITH INITIAL VIEW DEFINED BY THE CAMERA COORDINATION
SPREADSHEET OR COVERAGE ANGLES PROVIDED BY ARCHITECT. VARIFOCAL AIMING
WHERE REQUIRED TO OBTAIN INTENDED VIEW SHALL BE COMPLETED.
6 FOLLOWING SETTING THE INITIAL VIEW, COORDINATE AIMING MODIFICATIONS WITH
OWNER AND OBTAIN SIGN OFF PER CAMERA THROUGH THE CAMERA AIMING
COORDINATION SPREADSHEET.
7 CONFIGURE CAMERA TO RECORD TO NVR BASED ON OWNER'S RECORDING
CONFIGURATION STANDARDS. RESOLUTION, FRAMES PER SECOND,
CONTINUOUS/MOTION ACTIVATED RECORDING, ANALYTICS, AND ANY OTHER FEATURES
SHALL BE COORDINATED.
8 LABEL CAMERA HOUSING IN A LOCATION VISIBLE FROM THE GROUND. REFER TO
CAMERA LABELING DETAIL FOR REQUIREMENTS.
9 CAMERA SYMBOLS AND COVERAGE ANGLES SHALL BE SET IN VMS MAPS ONCE OWNER
HAS SIGNED OFF ON VIEWS.
10 THE SCOPE OF WORK FOR THIS PROJECT IS CAMERAS, MOUNTING HARDWARE, AND
CAMERA LICENSES FOR THE EXISTING VMS. CAMERA CABLING, NVRS, AND VMS ARE
ALREADY PROVIDED.
X
24X4824X48 24X42
X
24X48
X
X
X
24X48
X
X
24X42
24X48
X
24X36 24X42
24X48
X
X
24X42
X
24X42
W/D
T S
-A
WAP
SF
C
C
C
SS
SS
A
M
CR
IC
PRJ
A
TS-A
SF
SF
SF
SF
CRCR
CRIC
CR CR
C R
M
C R
C R
FV
H H
HHH
H
H
H
H
H H H
FV
WAP
WAP
WAP
R B
R B
LD
T V
-B T V
-B
FB
A
FB
T V
-B
SF
T V
-B
C
B
B B
B
B
SF
SS
WAP
WAP
D
D
M
CR
M
C R
GBB
T
T
B B
B
SF
H
SS
SS
WAP
WAP
WAP
WAP
W A
P
WAP
WAP
WAP
SE
S E
DB
S T
J
J
J
H
A N
T
A N
T
SF
KK
DO
DO
DODO
DO
DO
DO
DO
TV-B
W A
P
UNIT
A
UNIT
B
UNIT A UNIT C
CE-11
M1 1
+120"
CE-12
M1 1
+120"
CE-13
M1 1
+120"
CE-01
M1 1
+120"
C1-01
I1A 1
C1-02
I1A 1
B1
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L
L R
IG
H
T S
R E
S E
R V
E D
F
IR
S T
F L
O O
R T
E C
H N
O L O
G Y
P L
A N
U
N
IT
A
-2
.5
T
.5
A
W O
O D
L A
N D
E L E
M E
N T
A R
Y S
C H
O O
L
S E
C U
R
IT
Y C
A M
E R
A S
P o rt a g e
M ic h ig a n
P O
R T
A G
E P
U B
L
IC
S C
H O
O L
S
N O
V E
M B
E R
ISSUED FOR DATE
BULLETIN NO. 1 04/16/2026
1/8" = 1'-0"
FIRST FLOOR TECHNOLOGY PLAN - UNIT A
WOODLAND ELEMENTARY
UNIT A UNIT B
UNIT C
KEY PLAN
SCALE: NO SCALE
W/D
TS-ATV-A
A
HH
WAP
SF C
C
SF SF
C
C
C
SFSF
T S
-A
WAP SF
SF SF
C
C
C
CR
CR
H H
H
H
T S
-A
PRJ
SS
M
CR
CRCR
CR
T V
-A T
S -A
A
A
A
T V
-A T
S -A
A A
WAP
SF
WAP WAP
WAP
WAP
SF SF
SF
SF
HH
H
H
H
H
H
H
H
H
H
HH
FV FV FV FV
FV FV FV FV
H
H
H
FB
A
FB
TV-A
A
TS-A
SF
WAP
WAPSF
TV-B
FB
A
FB
WAP SF
P R
J A
C R
C R
C R
CR
CR
CR
A
B B
SF
SF
T
T
HD HD
HD HD
SF
SF
GBB
SSSS
SS
SS
SS
SS
SF
B
H
S4
T V
-B
SS
SF
WAP
WAP
WAP
WAP
WAP
WAP
WAP
S E
S E
DB
SCR
T V
L E
D
A N
T
SF
B
B
B
B
C
C
C
M
CR
M
C R
DO
DO
CB
CB
CBCB
CB
CB
CB
T V
-B
TV-B
CB
UNIT
A
UNIT
B
U N
IT
B
U N
IT
C
CE-06
M1 1
+120"
CE-07
M1 1
+120"
CE-08
M1 1
+120"
CE-09
M1 1
+120"
CE-10
M1 1
+120"
B1
B1
CE-14
M1 1
+120"
B1
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L
L R
IG
H
T S
R E
S E
R V
E D
F
IR
S T
F L
O O
R T
E C
H N
O L O
G Y
P L
A N
U
N
IT
B
-2
.5
T
.5
B
W O
O D
L A
N D
E L E
M E
N T
A R
Y S
C H
O O
L
S E
C U
R
IT
Y C
A M
E R
A S
P o rt a g e
M ic h ig a n
P O
R T
A G
E P
U B
L
IC
S C
H O
O L
S
N O
V E
M B
E R
WOODLAND ELEMENTARY
UNIT A UNIT B
UNIT C
KEY PLAN
SCALE: NO SCALE
ISSUED FOR DATE
BULLETIN NO. 1 04/16/2026
1/8" = 1'-0"
FIRST FLOOR TECHNOLOGY PLAN - UNIT B
REF
C
C
C
C
SS
SS
P R
J A
A
WAP
SF
SF
T S
-C
M
CR
IC
CR
WAP
SS
CR
M
CR
CR CR
M
C R
H H
H
H
H
H
H
H
H
H
H
H
H
H H
A
TS-ATV-A
TV-A TS-A
A
A
A
A
A
T V
-A
T V
-A
T V
-A
TV-A
T S
-A
T S
-A
T S
-A
TS-A
WAP
WAP
WAP
WAP
WAP
WAP
SF
SF
SF
SF
SF
SF
H
H
H
H
H
FV FV FV FV
H FV
H H
H H
H
A T
V -A
T S
-A
P R
J A
T S
-A A
M
CR
CR
CR
M
C R
FV
T
HD HD
FB
A
FB
FB
A
FB
FB
A
FB
FB
A
FB
SF
GBB
B
SS
SS
SS
SS
SS
SS SS
SF
SF
SFSF
SF
WAP
TV-B
B
B
B
TV-B
T
FV
T
FV
FV
T
SF
H
H
H
H
WAP
WAP
WAP
WAP
WAP
WAP
S E
H
J J
H
B
C
C
C
C
C
SF
UNIT A UNIT C
U N
IT
B
U N
IT
C
CE-01
M1 1
+120"
CE-02
M1 1
+120"
CE-03
M1 1
+120"
CE-04
M1 1
+120"
CE-05
M1 1
+120"
C1-01
I1A 1
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L
L R
IG
H
T S
R E
S E
R V
E D
F
IR
S T
F L
O O
R T
E C
H N
O L O
G Y
P L
A N
U
N
IT
C
-2
.5
T
.5
C
W O
O D
L A
N D
E L E
M E
N T
A R
Y S
C H
O O
L
S E
C U
R
IT
Y C
A M
E R
A S
P o rt a g e
M ic h ig a n
P O
R T
A G
E P
U B
L
IC
S C
H O
O L
S
N O
V E
M B
E R
WOODLAND ELEMENTARY
UNIT A UNIT B
UNIT C
KEY PLAN
SCALE: NO SCALE
ISSUED FOR DATE
1/8" = 1'-0"
FIRST FLOOR TECHNOLOGY PLAN - UNIT C
SURFACE CAMERA LABELING CEILING CAMERA LABELING
CAMERA NUMBER - TECH ROOM NUMBER - RACK - PORT
C -1
A
C
A
A100C 2A 14C-1
PRINTED ADHESIVE LABEL ON
HOUSING TO BE READILY
VISIBLE FOR IDENTIFICATION
FROM GROUND.
C-1 - A100C - 2A - 14
PRINTED ADHESIVE LABEL ON
HOUSING TO BE READILY
VISIBLE FOR IDENTIFICATION
FROM GROUND.
CAMERA NUMBER - TECH ROOM NUMBER - RACK - PORT
A100C 2A 14C-1 ---
PENDANT CAMERA LABELING POLE MOUNT CAMERA LABELING
CAMERA NUMBER - TECH ROOM NUMBER - RACK - PORT
C-1 - A100C - 2A - 14
A100C 2A 14C-1
PRINTED ADHESIVE LABEL ON
HOUSING TO BE READILY
VISIBLE FOR IDENTIFICATION
FROM GROUND.
C-1 - A100C - 2A - 14
PRINTED ADHESIVE LABEL ON
HOUSING TO BE READILY
VISIBLE FOR IDENTIFICATION
FROM GROUND.
CAMERA NUMBER - TECH ROOM NUMBER - RACK - PORT
A100C 2A 14C-1 ---
INT. CORNER CAMERA LABELING CORNER MOUNT CAMERA LABELING
CAMERA NUMBER - TECH ROOM NUMBER - RACK - PORT
A100C 2A 14C-1
PRINTED ADHESIVE LABEL ON
HOUSING TO BE READILY
VISIBLE FOR IDENTIFICATION
FROM GROUND.
C-1 - A100C - 2A - 14
C-1 - A100C - 2A - 14
PRINTED ADHESIVE LABEL ON
HOUSING TO BE READILY
VISIBLE FOR IDENTIFICATION
FROM GROUND.
CAMERA NUMBER - TECH ROOM NUMBER - RACK - PORT
A100C 2A 14C-1 ---
CORNER BRACKET
AND FASTENERS
EXTERIOR PENETRATION SHALL BE CONCEALED
BY MOUNTING BRACKET WHERE POSSIBLE. SG
JUNCTION BOX SHALL BE INSTALLED ON
INTERIOR SIDE OF WALL AT DEVICE ELEVATION
OR ABOVE ACCESBILE CEILING IF DEVICE IS
BELOW CEILING HEIGHT.
3/4" LIQUID TIGHT CONDUIT SHALL BE RUN
FROM INTERIOR MOUNTED SG BACKBOX
THROUGH PENETRATION TO CAMERA
MOUNTING BRACKET. PROVIDE 15' SERVICE
LOOP PRIOR TO INTERIOR JB. REFER TO
WAP AND CAMERA CABLE DETAIL AND
CABLE LEGEND FOR CABLING AND
TERMINATION REQUIREMENTS. LABEL WITH
PORT INFORMATION AT TERMINATION.
CAMERA MOUNTING
BRACKET
REFER TO FLOOR PLAN OR
CAMERA SCHEDULE FOR
ELEVATION REQUIREMENTS.
BOTTOM OF DECK
ACCESSIBLE CEILING
EXTERIOR CORNER MOUNT CAMERASCEILING MOUNT CAMERAS
WHEN INSTALLING IN GRID CEILING, CAMERA SHALL
BE CENTERED ON TILE. CAMERA SHALL BE
MOUNTED FLUSH TO SURFACE IN ALL CEILING
TYPES. CAMERA SHALL BE LABELED WITH PORT
INFORMATION. SECURITY CONTRACTOR SHALL
PROVIDE MOUNTING HARDWARE AS NEEDED.
CEILING
IN NON-GRID CEILING, ELECTRICAL CONTRACTOR SHALL
PROVIDE 3/4" FLEX CONDUIT FROM NEAREST CABLE
MANAGMENT SYSTEM TO CEILING PENETRATION, STUBBED
FLUSH. REFER TO PLANS FOR
DATA CABLE ORIGIN
INSTALL CABLING IN CONDUIT IN EXPOSED
AREAS; USE CABLE MANAGEMENT SYSTEMS
ELSEWHERE. PROVIDE 15' SERVICE LOOP
PRIOR TO TERMINATION. AT END OF SERVICE
LOOP, TERMINATE WITH SURFACE BOX AND
PATCH CABLE TO CAMERA HOUSING. REFER TO
WAP AND CAMERA CABLE DETAIL AND CABLE
LEGEND FOR CABLING AND TERMINATION
REQUIREMENTS. LABEL WITH PORT
INFORMATION AT TERMINATION.
FINISHED
FLOOR
OUTSIDE WALL
BOTTOM OF DECK
EXTERIOR SURFACE MOUNT CAMERAS
ACCESSIBLE CEILING
FINISHED
GRADE
3/4" CONDUIT FROM SG BOX
STUBBED INTO ACCESSIBLE CEILING
SPACE FOR SECURITY CABLING; BOX
AND CONDUIT SHALL BE AT DEVICE
ELEVATION UNLESS DEVICE IS BELOW
ACCESSIBLE CEILING
INSTALL CABLING IN CONDUIT IN EXPOSED AREAS; USE
CABLE MANAGEMENT SYSTEMS ELSEWHERE. PROVIDE
15' SERVICE LOOP PRIOR TO TERMINATION.
TERMINATE WITH SURFACE MOUNT BOX AT INTERIOR
JB, PATCH CABLE TO CAMERA HOUSING. REFER TO
WAP AND CAMERA CABLE DETAIL AND CABLE LEGEND
FOR CABLING AND TERMINATION REQUIREMENTS.
LABEL WITH PORT INFORMATION AT TERMINATION.
REFER TO PLANS OR
SECURITY CAMERA SCHEDULE
FOR DEVICE ELEVATION
REQUIREMENTS
CAMERA MOUNTED DIRECTLY TO EXTERIOR WALL.
LABEL PORT INFORMATION ON CAMERA HOUSING.
SG BOX FLUSH ON INTERIOR SIDE
OF PENETRATION
B
B BC 8
B
B
C
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L
L R
IG
H
T S
R E
S E
R V
E D
C A
M E
R A
D E
T A
IL
S
-2
.5
T
.5
W O
O D
L A
N D
E L E
M E
N T
A R
Y S
C H
O O
L
S E
C U
R
IT
Y C
A M
E R
A S
P o rt a g e
M ic h ig a n
P O
R T
A G
E P
U B
L
IC
S C
H O
O L
S
N O
V E
M B
E R
SCALE: NONE
EXTERIOR CORNER MOUNT CAMERA
SCALE: NONE
TYPICAL SECURITY CAMERA ROUGH-IN - CEILING
SCALE: NONE
TYPICAL SECURITY CAMERA ROUGH-IN - EXTERIOR WALL
ISSUED FOR DATE
BULLETIN NO. 1 04/16/2026
SECURITY CAMERA SCHEDULE
CAMERA NUMBER MAKE/MODEL MOUNTING HEIGHT MOUNTING TYPE EQUIPMENT ACCESSORIES DATA DROPS COMMENTS
C1-01 PND-A9081RV CEILING SBP-160HMW1 + SBP-300CMW 1
C1-02 PND-A9081RV CEILING N/A 1
CE-01 PNM-C32083RVQ 10' - 0" WALL SBP-250WMW + SBP-250C 1
CE-02 PNM-C32083RVQ 10' - 0" CORNER SBP-250WMW + SBP-250C + SBP-156KMW 1
CE-03 PNM-C32083RVQ 10' - 0" CORNER SBP-250WMW + SBP-250C + SBP-156KMW 1
CE-04 PNM-C32083RVQ 10' - 0" CORNER SBP-250WMW + SBP-250C + SBP-156KMW 1
CE-05 PNM-C32083RVQ 10' - 0" CORNER SBP-250WMW + SBP-250C + SBP-156KMW 1
CE-06 PNM-C32083RVQ 10' - 0" WALL SBP-250WMW + SBP-250C 1
CE-07 PNM-C32083RVQ 10' - 0" CORNER SBP-250WMW + SBP-250C + SBP-156KMW 1
CE-08 PNM-C32083RVQ 10' - 0" CORNER SBP-250WMW + SBP-250C + SBP-156KMW 1
CE-09 PNM-C32083RVQ 10' - 0" CORNER SBP-250WMW + SBP-250C + SBP-156KMW 1
CE-10 PNM-C32083RVQ 10' - 0" CORNER SBP-250WMW + SBP-250C + SBP-156KMW 1
CE-11 PNM-C32083RVQ 10' - 0" CORNER SBP-250WMW + SBP-250C + SBP-156KMW 1
CE-12 PNM-C32083RVQ 10' - 0" CORNER SBP-250WMW + SBP-250C + SBP-156KMW 1
CE-13 PNM-C32083RVQ 10' - 0" CORNER SBP-250WMW + SBP-250C + SBP-156KMW 1
CE-14 PNM-C32083RVQ 10' - 0" CORNER SBP-250WMW + SBP-250C + SBP-156KMW 1
SCALE: NONE
INTERIOR SECURITY CAMERA CABLING DETAIL
SCALE: NONE
EXTERIOR SECURITY CAMERA CABLING DETAIL
EXTERIOR CAMERA EQUIPMENT SCHEDULE
KEY # DESCRIPTION MANUFACTURER PART # COMMENTS
1 NETWORK SWITCH PROVIDED BY OWNER PROVIDED BY OWNER
5 PATCH PANEL REFER TO RACK
SCHEDULE
REFER TO RACK
SCHEDULE
6 SURFACE MOUNT BOX REFER TO SCHEDULE REFER TO SCHEDULE
7 ETHERNET SURGE PROECTOR TRIPPLITE B110-SP-POE-1 ONLY NEEDED FOR CAMERAS THAT ARE NOT
MOUNTED DIRECTLY TO BUILDING
8 CAMERA SEE CAMERA SCHEDULE SEE CAMERA SCHEDULE
B PATCH CORD REFER TO SCHEDULE REFER TO SCHEDULE
C CATEGORY CABLE REFER TO SCHEDULE REFER TO SCHEDULE INCLUDE MINIMUM 15FT SERVICE LOOP
INTERIOR CAMERA EQUIPMENT SCHEDULE
KEY # DESCRIPTION MANUFACTURER PART # COMMENTS
1 NETWORK SWITCH PROVIDED BY OWNER PROVIDED BY OWNER
5 PATCH PANEL REFER TO RACK
SCHEDULE
REFER TO RACK
SCHEDULE
6 SURFACE MOUNT BOX REFER TO SCHEDULE REFER TO SCHEDULE
8 CAMERA SEE CAMERA SCHEDULE SEE CAMERA SCHEDULE
B PATCH CORD REFER TO SCHEDULE REFER TO SCHEDULE
C CATEGORY CABLE REFER TO SCHEDULE REFER TO SCHEDULE INCLUDE MINIMUM 15FT SERVICE LOOP
B1
| 21237.54 PPS WOODLAND - SECURITY CAMERAS - BULLETIN 01.pdf |
| Sheets |
| T 101.54A - FIRST FLOOR TECHNOLOGY PLAN - UNIT A |
| T 101.54B - FIRST FLOOR TECHNOLOGY PLAN - UNIT B |
| T 441.54 - CAMERA DETAILS |
| 21237.54 PPS WOODLAND - SECURITY CAMERAS.pdf |
| Sheets |
| G 001.54 - COVER SHEET |
| T 101.54A - FIRST FLOOR TECHNOLOGY PLAN - UNIT A |
| T 101.54B - FIRST FLOOR TECHNOLOGY PLAN - UNIT B |
| T 101.54C - FIRST FLOOR TECHNOLOGY PLAN - UNIT C |
| T 441.54 - CAMERA DETAILS |
| TG 001.54 - TECHNOLOGY SYMBOLS AND GENERAL NOTES |
File details come from the government source that posted it. Updated .