TOKAY_04-124690_DWG_A.pdf
PDF 5 MB Posted
- Solicitation number
- 25/26-0026i
- Issued by
- San Bernardino County, California
About this file
These architectural documents are for the Tokay Elementary Play Equipment Replacement project for the Fontana Unified School District, located at 7846 Tokay Ave. in Fontana, California. The project is scheduled for June 2025 and involves replacing the existing playground equipment with a new play structure layout that includes multiple play components such as a playhouse, bell panel, chimes panel, glide slides, rock climbers, a solar climber, cabana roofs, and transfer stations. The project plans are designed to meet 2022 California Building Code standards and various accessibility requirements, with specific attention to path of travel compliance and safety regulations.
The site plan shows the playground will be situated within the existing school grounds, featuring an artificial turf safety surfacing area of 1,226 square feet and a contrasting concrete strip leading to steps. The design incorporates accessibility features like a 30" x 48" clear space and an accessible route. The project documentation is prepared by Lionakis architectural firm and has been reviewed and approved by the Division of the State Architect (DSA), with an identification stamp dated 06/27/2025. The play structure is designed by Davebang and appears to be a comprehensive replacement of the existing playground equipment to enhance safety and play opportunities for elementary school students.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT LOCATION
VICINITY MAP PROJECT DIRECTORY
OWNER
FONTANA UNIFIED SCHOOL DISTRICT
9680 CITRUS AVENUE
FONTANA, CA 92335
CONTACT: FACILITIES PLANNING DESIGN AND CONSTRUCTION
CONTACT NAME: SAMER ALUZBAIDI, EXECUTIVE DIRECTOR
PHONE: 909.357.7528
ARCHITECT
LIONAKIS
2050 MAIN STREET, SUITE 400
IRVINE, CA 92614
CONTACT: TONY PACHECO-TAYLOR
PHONE: 949.955.1919
EMAIL: TONY.PACHECOTAYLOR@LIONAKIS.COM
THIS PROJECT SCOPE INCLUDES THE FOLLOWING:
NEW PLAY EQUIPMENT AND PLAY SURFACING REPLACEMENT.
SCOPE OF PROJECT
N/A
DEFERRED SUBMITTALS
BUILDING IDENTIFIER - WHERE OCCURS
DISCIPLINE DESIGNATOR - LEVEL 1
DISCIPLINE DESIGNATOR - LEVEL 2
REPLACE DASH WHERE OCCURS
SHEET TYPE SUBSET DESIGNATOR
LEVEL/SEQUENCE DESIGNATOR
AREA IDENTIFIER - WHERE OCCURS
SHEET TYPE DESIGNATOR
C.A-123AB
UNIQUE PORTION IDENTIFIER - WHERE OCCURS
SHEET TYPE DESIGNATORS
0 - GENERAL
1 - PLANS
2 - ELEVATIONS
3 - SECTIONS
4 - LARGE SCALE VIEWS
5 - DETAILS
6 - SCHEDULES & DIAGRAMS
7 - USER DEFINED
8 - USER DEFINED
9 - 3D REPRESENTATIONS
DISCIPLINE DESIGNATORS - LEVEL 1
G GENERAL
H HAZARDOUS MATERIALS
V SURVEY/MAPPING
B GEOTECHNICAL
C CIVIL
L LANDSCAPE
S STRUCTURAL
A ARCHITECTURAL
I INTERIORS
Q EQUIPMENT
F FIRE PROTECTION
P PLUMBING
D PROCESS
M MECHANICAL
E ELECTRICAL
W DISTRIBUTED ENERGY
T TELECOMMUNICATIONS
R RESOURCE
X OTHER DISCIPLINES
Z CONTRACTOR/SHOP DRAWINGS
O OPERATIONS
SHEET IDENTIFICATION LEGEND
ARCHITECTURAL SYMBOLS LEGEND
B3 A-501
B3 A-501
A4 A-201
D2 A-512
TOC 98'-8"
B3 A-301
A2 A-303
A2 A-303
ROOM NAME
NORTH
PLAN
MATCH LINE
SEE XX / X-XXX
A
A-202 A2
A1
A2A4
A3
A-202
LEVEL 1
100'-0"
D2 A-512
D2 A-512
DETAIL INDICATOR - REFERENCE &
DETAIL INDICATOR - ITEM
DETAIL INDICATOR - SECTION & DETAIL
INDICATOR - SECTION ITEM
SECTION INDICATOR - PARTIAL
BUILDING/WALL &
DETAIL INDICATOR - AREA
SECTION INDICATOR - BUILDING
ELEVATION INDICATOR - EXTERIOR
ELEVATION INDICATOR - INTERIOR,
SINGLE & MULTIPLE VIEW
MATCH LINE INDICATOR
REFERENCE GRID WITH REFERENCE GRID LINES
REVISION INDICATOR & REVISION CLOUD
ROOM IDENTIFIER WITH ROOM NAME & NUMBER
ELEVATION INDICATOR - LEVEL & SPOT
WINDOW OR LOUVER IDENTIFIER
KEYNOTE INDICATOR
PLAN NORTH & TRUE NORTH INDICATOR
PROJECT LOCATION
LOCATION MAP
1 2 3 4 5
D
C
B
A
SHEET
TITLE
MANAGEMENT
ISSUED
PROJECT
SEAL
CONSULTANT
CLIENT PROJECT NO:
COPYRIGHT:
LIONAKIS PROJECT NO:
LIONAKIS 2024
IF
T
HI
S
SH
EE
T
IS
N
OT
"x
IT
IS
A R
ED
UC
ED
P
RI
NT
SC
AL
E
AC
CO
RD
IN
GL
Y
1/4
1/2
1"
2"
CLIENT
6/2 6/2
5 5
:21 :50
P M
Au tod es k D oc s:/
/02
.21
T ok ay E lem en tar y P
OT
/02
.21 _A
RC
HM
ST
R_
R2 4_
CE
NT
RA
L.r vt
G-001
COVER SHEET
7846 TOKAY AVE.
FONTANA, CA 92336
OTC PACKAGE
025154.21
FONTANA UNIFIED SCHOOL DISTRICT
TOKAY ELEMENTARY SCHOOL
JUNE 2025
TOKAY ELEMENTARY PLAY EQUIPMENT REPLACEMENT
FONTANA UNIFIED SCHOOL DISTRICT
TOKAY ELEMENTARY PLAY
EQUIPMENT REPLACEMENT
7846 TOKAY AVE.
FONTANA, CA 92336
9680 CITRUS AVENUE
FONTANA, CA 92335
SEE UNITED STATES NATIONAL
CAD STANDARD FOR ANY
ABBREVIATIONS NOT LISTED
BELOW.
& AND
@ AT
(E) EXISTING
' FOOT, FEET
" INCH(ES)
# NUMBER
ALUM ALUMINUM
ARCH ARCHITECTURAL
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT / ENGINEER
AB ANCHOR BOLT
AC ASPHALTIC CONCRETE
ACC ACCESSIBLE
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACST ACOUSTIC
AD AREA DRAIN
ADC AUTOMATIC DOOR CLOSER
ADO AUTOMATIC DOOR OPERATOR
ADDL ADDITIONAL
ADJ SHV ADJUSTABLE SHELVING
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AGGR AGGREGATE
AHU AIR HANDLING UNIT
ASSY ASSEMBLY
BD BOARD
BKG BACKING
BLDG BUILDING
BM BEAM
BM BENCHMARK
BOT BOTTOM
BTWN BETWEEN
BUR BUILT-UP ROOFING
BW BOTH WAYS
C CHANNEL
CAB CABINET
CB CATCH BASIN
CBC CALIFORNIA BUILDING CODE
CEM CEMENT
CEM PLAS CEM PLASTER
CFLG COUNTERFLASHING
CFMF COLD-FORMED METAL FRAMING
CG CORNER GUARD
CI CAST IRON
CJ CONSTRUCTION JOINT /
CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CNTR COUNTER
CO CLEANOUT
COL COLUMN
CONC CONCRETE
CONSTR CONSTRUCTION
CONT CONTINUE / CONTINUOUS
COTG CLEANOUT TO GRADE
CP CONTROL PANEL
CPT CARPET
CRS COLD ROLLED STEEL
CSK COUNTER SUNK
CSWK CASEWORK
CT CERAMIC TILE
CTR CENTER
DBL DOUBLE
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
LIST OF ARCHITECTURAL ABBREVIATIONS
SHEET INDEX
GENERAL
G-001 COVER SHEET
ARCHITECTURAL
AS101 OVERALL SITE PLAN
AS102 ENLARGED SITE PLAN
AS103 ENLARGED SITE PLAN
DHM DETENTION HOLLOW METAL
DIA DIAMETER
DIM DIMENSION
DS DOWNSPOUT
DSP DRY STANDPIPE
DWG DRAWING
DWR DRAWER
EA EACH
EGSB EXTERIOR GYPSUM SHEATHING
BOARD
EIFS EXTERIOR INSULATION AND
FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC / ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSURE
EPB ELECTRICAL PANEL BOARD
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXST EXISTING
EXP EXPANSION
EXT EXTERIOR
FA FIRE ALARM
FB FLAT BAR
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FIN FINISH
FLG FLOORING
FLL FLOW LINE
FLR FLOOR
FOC FACE OF CONCRETE/CURB
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUD
FOW FACE OF WALL
FP FIREPROOF
FRP FIBERGLASS REINFORCED
PLASTIC
FT FEET / FOOT
FTG FOOTING
FURG FURRING
FUT FUTURE
G GROUND; NATURAL GAS
GA GAGE
GALV GALVANIZED
GB GRAB BAR
GI GALVANIZED IRON
GLU LAM GLUED LAMINATED WOOD
GYP GYPSUM
HB HOSE BIB
HC HOLLOW CORE
HDBD HARDBOARD
HDW HARDWARE
HDWD HARDWOOD
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
ID INSIDE DIAMETER
INSUL INSULATION
INT INTERIOR
JAN JANITOR
KIT KITCHEN
L ANGLE
LAB LABORATORY
LAV LAVATORY
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MR MOISTURE RESISTANT
MTD MOUNTED
MTL METAL
MULL MULLION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O/ OVER
OC ON CENTER
OD OUTSIDE DIAMETER
OF/CI OWNER FURNISHED /
CONTRACTOR INSTALLED
OFF OFFICE
OGL OBSCURE GLASS
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
PAF POWER ACTUATED FASTENER
PL PROPERTY LINE; PLATE
PLAM PLASTIC LAMINATE
PLB PLUMB
PLBG PLUMBING
PLYWD PLYWOOD
PNL PANEL
PROP PROPERTY
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT; PAINT
PTN PARTITION
PV PHOTOVOLTAIC
QT QUARRY TILE
R RADIUS; RISER
RD ROOF DRAIN
REBAR REINFORCING STEEL BAR
REF REFERENCE
REF REFRIGERATOR
REINF REINFORCE / REINFORCING
REQD REQUIRED
RESIL RESILIENT
RM ROOM
RO ROUGH OPENING
RWD REDWOOD
RWL RAIN WATER LEADER
SAD SEE ARCHITECTURAL
DRAWINGS
SATC SUSPENDED ACOUSTICAL TILE
CEILING
SB SPLASH BLOCK
SC SOLID CORE
SCHED SCHEDULE
SD STORM DRAIN
SDST SELF DRIVING, SELF TAPPING
SHT SHEET
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SLNT SEALANT
SM SHEET METAL
SPEC SPECIFICATION
SQ SQUARE
SS SANITARY SEWER; SERVICE
SINK
SST STAINLESS STEEL
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SUSP CLG SUSPENDED CEILING
SV SHEET VINYL
SYMM SYMMETRICAL
SYS SYSTEM
T TREAD
T&G TONGUE & GROOVE
TEL TELEPHONE
THK THICKNESS
TMH TOP OF MANHOLE
TMPD TEMPERED
TO TOP OF
TOC TOP OF CURB
TOF TOP OF FRAME
TOJ TOP OF JOIST
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF STEEL
TOW TOP OF WALL
TV TELEVISION
TYP TYPICAL
UC UNDER COUNTER/CABINET
UNO UNLESS NOTED OTHERWISE
UON UNLESS OTHERWISE NOTED
UR URINAL
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VWC VINYL WALL COVERING
VWF VINYL WALL FABRIC
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
WH WATER HEATER
WO WHERE OCCURS
WP WORKING POINT
WPM WATERPROOF MEMBRANE
WSCT WAINSCOT
WT WEIGHT
WTR WATER
WWR WELDED WIRE
REINFORCEMENT
2050 Main Street, Suite 400 Irvine, CA 92614 P 949.955.1919 F 949.955.9175 www.lionakis.com
C35462
LI
CE
NS
ED A
T
RCHITEC
R 5EN. 0 -30- 2
S AT
AT E
OF CA L I
FO
RN
I
D.Y
OH
PAC
TN
A
N -O
CEH
T A Y L O R
MARK DATE DESCRIPTION
1. SPECIAL REQUIREMENTS:
-ACCESSIBLE PATH OF TRAVEL PER SHEET AS101
2. CONSTRUCTION SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS,
INCLUDING BUT NOT LIMITED TO:
TITLE 19 CCR, PUBLIC SAFETY, STATE FIRE MARSHALL REGULATIONS
TITLE 24 CCR, PART 1 - 2022 CALIFORNIA BUILDING STANDARDS ADMINISTRATIVE CODE
TITLE 24 CCR, PART 2 - 2022 CALIFORNIA BUILDING CODE, VOL.1 & 2 (CBC)
TITLE 24 CCR, PART 3 - 2022 CALIFORNIA ELECTRICAL CODE (CEC)
TITLE 24 CCR, PART 4 - 2022 CALIFORNIA MECHANICAL CODE (CMC)
TITLE 24 CCR, PART 5 - 2022 CALIFORNIA PLUMBING CODE (CPC)
TITLE 24 CCR, PART 6 - 2022 CALIFORNIA ENERGY CODE
TITLE 24 CCR, PART 9 - 2022 CALIFORNIA FIRE CODE (CFC)
TITLE 24 CCR, PART 11 - 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE
TITLE 24 CCR, PART 12 - 2022 CALIFORNIA REFERENCED STANDARDS
2022 NFPA 13, INSTALLATION OF SPRINKLER SYSTEMS (CA AMENDED)
2019 NFPA 14, INSTALLATION OF STANDPIPE AND HOSE SYSTEMS
2021 NFPA 17, DRY CHEMICAL EXTINGUISHING SYSTEMS
2021 NFPA 17A, WET CHEMICAL EXTINGUISHING SYSTEMS
2022 NFPA 20, INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION
2018 NFPA 22, WATER TANKS FOR PRIVATE FIRE PROTECTION
2022 NFPA 24, INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES
2013 NFPA 25, INSPECTION, TESTING, MAINTENANCE OF WATER-BASED FIRE PROTECTION
SYSTEMS (CA AMENDED)
2022 NFPA 72, NATIONAL FIRE ALARM CODE (CA AMENDED)
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN
3. CHANGES TO THE APPROVED DRAWINGS OR SPECIFICATIONS SHALL BE MADE BY ADDENDA OR
CONSTRUCTION CHANGE DOCUMENTS (CCD) APPROVED BY THE DIVISION OF THE STATE
ARCHITECT, AS REQUIRED BY THE SECTION 4-338 OF CALIFORNIA CODE OF REGULATIONS,
TITLE 24, PART I. (CAC 4-338) SUBSTITUTIONS OF PRODUCTS OR PROCESSES WHICH AFFECT STRUCTURAL SAFETY, FIRE AND LIFE-SAFETY, OR ACCESSIBILITY SHALL BE SUBMITTED AS AN
ADDDENDUM OR CONSTRUCTION CHANGE DOCUMENT TO DSA FOR REVIEW AND APPROVAL.
GENERAL NOTES
TEST MARK (For DSA Use Only) Prior to adding document to the Session the Plan Reviewer shall place this test mark off the top edge of the first sheet and change status to "INCORPORATE". If Back-check menu does not show or the color does not change to green, the Plan Reviewer shall fix the back-check menu. For guidance on how to fix the back-check menu, refer to "_DSA EPR Support > Help Desk > Fixing Back Check Menu"
TOTAL SHEETS: 4
APP. INC:
REVIEWED FOR
SS FLS ACS
DATE:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
04-124690
06/27/2025
SITE LEGEND
GENERAL NOTES
1.
2.
3.
CONTRACTOR TO FIELD VERIFY SPOT ELEVATION PRIOR TO SETTING FINAL GRADES.
THE GROUND AROUND ANY BUILDING SHALL BE SLOPE A MINIMUM OF 5% AWAY FROM THE
BUILDING FOR AT LEAST 10 FEET FROM THE FACE OF THE WALL PER CBC, AND IMPERVIOUS
SURFACES SHALL BE SLOPED AT A MINIMUM OF 2% AWAY FROM THE BUILDING.
ACCESS TO A PUBLIC WAY: THE EXIT DISCHARGE SHALL PROVIDE A DIRECT AND
(CBC 1028.5) UNOBSTRUCTED ACCESS TO PUBLIC WAY.
EXISTING BUILDING WITH NO SCOPE OF WORK
EXISTING FIRE TRUCK ACCESS ROAD (MINIMUM
20'-0" CLEAR WIDTH)
EXISTING SAFE DISPERSAL AREA
EXISTING PATH OF TRAVEL (SEE SHEET AS102
FOR SLOPE INFORMATION)
"DESIGN PROFESSIONAL IN GENERAL
RESPONSIBLE CHARGE STATEMENT : THE POT
IDENTIFIED IN THESE CONSTRUCTION
DOCUMENTS IS COMPLIANT WITH THE CURRENT
APPLICABLE CALIFORNIA BUILDING CODE
ACCESSIBILITY PROVISIONS FOR PATH OF
TRAVEL REQUIREMENTS FOR ALTERATIONS,
ADDITIONS AND STRUCTURAL REPAIRS. AS
PART OF THE DESIGN OF THIS PROJECT, THE
POT WAS EXAMINED AND ANY ELEMENTS,
COMPONENTS OR PORTIONS OF THE POT THAT
WERE DETERMINED TO BE NONCOMPLIANT 1)
HAS BEEN IDENTIFIED AND 2) THE DETAILS,
DRAWINGS AND SPECIFICATIONS
INCORPORATED INTO THESE CONSTRUCTION
DOCUMENTS. ANY NONCOMPLIANT ELEMENTS,
COMPONENTS OR PORTIONS OF THE POT THAT
WILL NOT BE CORRECTED BY THIS PROJECT
BASED ON VALUATION THRESHOLD LIMITATIONS
OR A FINDING OF UNREASONABLE HARDSHIP
ARE SO INDICATED IN THESE CONSTRUCTION
DOCUMENTS.
DURING CONSTRUCTION, IF POT ITEMS WITHIN
THE SCOPE OF THE PROJECT REPRESENTED AS
CODE COMPLIANT ARE FOUND TO BE
NONCONFORMING BEYOND REASONABLE
CONSTRUCTION TOLERANCES, THEY SHALL BE
BOUGHT INTO COMPLIANCE WITH THE CBC AS A
PART OF THIS PROJECT BY MEANS OF
CONSTRUCTION CHANGE DOCUMENT.
"ACCESSIBLE PATH OF TRAVEL AS INDICATED
ON PLAN IS A BARRIER-FREE ACCESS ROUTE
WITHOUT ABRUPT LEVEL CHANGES EXCEEDING
½" IF BEVELED AT 1:2 MAXIMUM SLOPE OR
VERTICAL LEVEL CHANGES NOT EXCEEDING ¼"
MAXIMUM AND AT LEAST 48" IN WIDTH.
SURFACE IS STABLE, FIRM, AND SLIP-
RESISTANT. CROSS-SLOPE SHALL NOT BE
STEEPER THAN 1:48 AND SLOPE IN THE
DIRECTION OF TRAVEL SHALL NOT BE STEEPER
THAN 1:20. ACCESSIBLE PATH OF TRAVEL
SHALL BE MAINTAINED FREE OF OVERHANGING
OBSTRUCTIONS TO 80" MINIMUM AND FREE OF
OBJECTS PROTRUDING MORE THAN 4" FROM
THE WALL, ABOVE 27" AND LESS THAN 80"
ABOVE THE FLOOR. ARCHITECT SHALL VERIFY
THAT THERE ARE NO BARRIERS IN THE PATH OF
TRAVEL."
EXISTING FENCE
TO
K A Y A
VE
CLASSROOMS
BLDG. A
A# 44121
PRESCHOOL
A# 56797
A# 48074
A# 67536
CLASSROOMS
BLDG. B
A# 46179
A# 67536
A# 67536
A# 67536
A# 67536
A# 67536A# 67536
A# 67536A# 67536
A# 67536A# 67536
CLASSROOMS
BLDG. D
A# 47056
MULTI PURPOSE
BLDG. C
A# 47056
ADMINISTRATION
BLDG. E
A# 47056
(E) FIELD AREA
AS102
SHADE
STRUCTURE
A#03-106747
(E) GRASS AREA
(E) A/C PAVING (E) CONCRETE
PAVING
SCALE 1" = 30'-0"1 SITE PLAN - OVERALL
1 2 3 4 5
D
C
B
A
SHEET
TITLE
MANAGEMENT
ISSUED
PROJECT
SEAL
CONSULTANT
CLIENT PROJECT NO:
COPYRIGHT:
LIONAKIS PROJECT NO:
LIONAKIS 2024
IF
T
HI
S
SH
EE
T
IS
N
OT
"x
IT
IS
A R
ED
UC
ED
P
RI
NT
SC
AL
E
AC
CO
RD
IN
GL
Y
1/4
1/2
6/2
5 5
:21 :51
P M
Au tod es k D oc s:/
/02
.21
T ok ay E lem en tar y P
OT
/02
.21 _A
RC
HM
ST
R_
R2 4_
CE
NT
RA
L.r vt
AS101
OVERALL SITE PLAN
025154.21
FONTANA UNIFIED SCHOOL DISTRICT
TOKAY ELEMENTARY PLAY
EQUIPMENT REPLACEMENT
7846 TOKAY AVE.
FONTANA, CA 92336
9680 CITRUS AVENUE
FONTANA, CA 92335
2050 Main Street, Suite 400 Irvine, CA 92614 P 949.955.1919 F 949.955.9175 www.lionakis.com
C35462
LI
CE
NS
ED A
T
RCHITEC
R 5EN. 0 -30- 2
S AT
AT E
OF CA L I
FO
RN
I
D.Y
OH
PAC
TN
A
N -O
CEH
T A Y L O R
MARK DATE DESCRIPTION
NORTH
A#04-107827
APP. INC:
REVIEWED FOR
SS FLS ACS
DATE:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
04-124690
SITE LEGEND
GENERAL NOTES
1.
2.
3.
CONTRACTOR TO FIELD VERIFY SPOT ELEVATION PRIOR TO SETTING FINAL GRADES.
THE GROUND AROUND ANY BUILDING SHALL BE SLOPE A MINIMUM OF 5% AWAY FROM THE
BUILDING FOR AT LEAST 10 FEET FROM THE FACE OF THE WALL PER CBC, AND IMPERVIOUS
SURFACES SHALL BE SLOPED AT A MINIMUM OF 2% AWAY FROM THE BUILDING.
ACCESS TO A PUBLIC WAY: THE EXIT DISCHARGE SHALL PROVIDE A DIRECT AND
(CBC 1028.5) UNOBSTRUCTED ACCESS TO PUBLIC WAY.
EXISTING BUILDING WITH NO SCOPE OF WORK
EXISTING FIRE TRUCK ACCESS ROAD (MINIMUM
20'-0" CLEAR WIDTH)
EXISTING SAFE DISPERSAL AREA
EXISTING PATH OF TRAVEL (SEE SHEET AS102
FOR SLOPE INFORMATION)
"DESIGN PROFESSIONAL IN GENERAL
RESPONSIBLE CHARGE STATEMENT : THE POT
IDENTIFIED IN THESE CONSTRUCTION
DOCUMENTS IS COMPLIANT WITH THE CURRENT
APPLICABLE CALIFORNIA BUILDING CODE
ACCESSIBILITY PROVISIONS FOR PATH OF
TRAVEL REQUIREMENTS FOR ALTERATIONS,
ADDITIONS AND STRUCTURAL REPAIRS. AS
PART OF THE DESIGN OF THIS PROJECT, THE
POT WAS EXAMINED AND ANY ELEMENTS,
COMPONENTS OR PORTIONS OF THE POT THAT
WERE DETERMINED TO BE NONCOMPLIANT 1)
HAS BEEN IDENTIFIED AND 2) THE DETAILS,
DRAWINGS AND SPECIFICATIONS
INCORPORATED INTO THESE CONSTRUCTION
DOCUMENTS. ANY NONCOMPLIANT ELEMENTS,
COMPONENTS OR PORTIONS OF THE POT THAT
WILL NOT BE CORRECTED BY THIS PROJECT
BASED ON VALUATION THRESHOLD LIMITATIONS
OR A FINDING OF UNREASONABLE HARDSHIP
ARE SO INDICATED IN THESE CONSTRUCTION
DOCUMENTS.
DURING CONSTRUCTION, IF POT ITEMS WITHIN
THE SCOPE OF THE PROJECT REPRESENTED AS
CODE COMPLIANT ARE FOUND TO BE
NONCONFORMING BEYOND REASONABLE
CONSTRUCTION TOLERANCES, THEY SHALL BE
BOUGHT INTO COMPLIANCE WITH THE CBC AS A
PART OF THIS PROJECT BY MEANS OF
CONSTRUCTION CHANGE DOCUMENT.
"ACCESSIBLE PATH OF TRAVEL AS INDICATED
ON PLAN IS A BARRIER-FREE ACCESS ROUTE
WITHOUT ABRUPT LEVEL CHANGES EXCEEDING
½" IF BEVELED AT 1:2 MAXIMUM SLOPE OR
VERTICAL LEVEL CHANGES NOT EXCEEDING ¼"
MAXIMUM AND AT LEAST 48" IN WIDTH.
SURFACE IS STABLE, FIRM, AND SLIP-
RESISTANT. CROSS-SLOPE SHALL NOT BE
STEEPER THAN 1:48 AND SLOPE IN THE
DIRECTION OF TRAVEL SHALL NOT BE STEEPER
THAN 1:20. ACCESSIBLE PATH OF TRAVEL
SHALL BE MAINTAINED FREE OF OVERHANGING
OBSTRUCTIONS TO 80" MINIMUM AND FREE OF
OBJECTS PROTRUDING MORE THAN 4" FROM
THE WALL, ABOVE 27" AND LESS THAN 80"
ABOVE THE FLOOR. ARCHITECT SHALL VERIFY
THAT THERE ARE NO BARRIERS IN THE PATH OF
TRAVEL."
EXISTING FENCE
CLASSROOMS
BLDG. A
A# 44121
PRESCHOOL
A# 56797
AS103
.3%
0.6%
.1% 0.2%
(E) SHADE
STRUCTURE
A#04-107827
30"x48" TRANSFER
STATION
1.6%
.8%
.77%
1.8
.2%
1.7
.9%
.0%
1.1%
.2%
1.3%
.2%
.4%
.1.
(E) A/C PAVING
(E) CONC. PAVING
(E) A/C PAVING
AS102
NEW PLAY STRUCTURE &
ACCESSIBLE PLAYGROUND
TURF SURFACE. (SEE
SUPPORTING DOCUMENTS FOR
ADDITIONAL INFORMATION)
2%
MA
X
2%
MAX
REPLACE EXISTING
TURF AND
SUBGRADE WITH
ACCESSIBLE
PLAYGROUND
TURF/SUBGRADE
DEMO (E) GATE
BASE MATERIAL
BELOW TURF- PER
MANUFACTURER'S
SPECIFICATIONS
(E)
CONC
WALK
CONCRETE WALK - TURF
FLUSH TRANSITION ACCESSIBLE
PLAYGROUND TURF
FACE
THE TRANSITION FROM CONCRETE SURFACE TO NEW SYNTHETIC PLAY
SURFACE SHALL COMPLY WITH CBC 11B-303.1
1 2 3 4 5
D
C
B
A
SHEET
TITLE
MANAGEMENT
ISSUED
PROJECT
SEAL
CONSULTANT
CLIENT PROJECT NO:
COPYRIGHT:
LIONAKIS PROJECT NO:
LIONAKIS 2024
IF
T
HI
S
SH
EE
T
IS
N
OT
"x
IT
IS
A R
ED
UC
ED
P
RI
NT
SC
AL
E
AC
CO
RD
IN
GL
Y
1/4
1/2
7/2
5 1
2:4 0:0
9 P M
Au tod es k D oc s:/
/02
.21
T ok ay E lem en tar y P
OT
/02
.21 _A
RC
HM
ST
R_
R2 4_
CE
NT
RA
L.r vt
AS102
ENLARGED SITE PLAN
025154.21
FONTANA UNIFIED SCHOOL DISTRICT
TOKAY ELEMENTARY PLAY
EQUIPMENT REPLACEMENT
7846 TOKAY AVE.
FONTANA, CA 92336
9680 CITRUS AVENUE
FONTANA, CA 92335
2050 Main Street, Suite 400 Irvine, CA 92614 P 949.955.1919 F 949.955.9175 www.lionakis.com
C35462
LI
CE
NS
ED A
T
RCHITEC
R 5EN. 0 -30- 2
S AT
AT E
OF CA L I
FO
RN
I
D.Y
OH
PAC
TN
A
N -O
CEH
T A Y L O R
NORTH
MARK DATE DESCRIPTION
SCALE 1/8" = 1'-0"1 SITE PLAN - ENLARGED
1 1/2" = 1'-0"2
APP. INC:
REVIEWED FOR
SS FLS ACS
DATE:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
04-124690
GENERAL NOTE
SEE SHEET AS102 FOR ADDITIONAL
SURFACE INFORMATION
A#03-106747
1 2 3 4 5
D
C
B
A
SHEET
TITLE
MANAGEMENT
ISSUED
PROJECT
SEAL
CONSULTANT
CLIENT PROJECT NO:
COPYRIGHT:
LIONAKIS PROJECT NO:
LIONAKIS 2024
IF
T
HI
S
SH
EE
T
IS
N
OT
"x
IT
IS
A R
ED
UC
ED
P
RI
NT
SC
AL
E
AC
CO
RD
IN
GL
Y
1/4
1/2
6/2
5 5
:21 :55
P M
Au tod es k D oc s:/
/02
.21
T ok ay E lem en tar y P
OT
/02
.21 _A
RC
HM
ST
R_
R2 4_
CE
NT
RA
L.r vt
AS103
ENLARGED SITE PLAN
025154.21
FONTANA UNIFIED SCHOOL DISTRICT
TOKAY ELEMENTARY PLAY
EQUIPMENT REPLACEMENT
7846 TOKAY AVE.
FONTANA, CA 92336
9680 CITRUS AVENUE
FONTANA, CA 92335
2050 Main Street, Suite 400 Irvine, CA 92614 P 949.955.1919 F 949.955.9175 www.lionakis.com
C35462
LI
CE
NS
ED A
T
RCHITEC
R 5EN. 0 -30- 2
S AT
AT E
OF CA L I
FO
RN
I
D.Y
OH
PAC
TN
A
N -O
CEH
T A Y L O R
NORTH
MARK DATE DESCRIPTION
SCALE 3/8" = 1'-0"1 PLAY STRUCTURE LAYOUT
GROUND SURFACE OF PLAY AREAS:
GROUND SURFACES ON ACCESSIBLE ROUTES, CLEAR FLOOR OR GROUND
SPACES, AND TURNING SPACE FOR PLAY AREA SHALL COMPLY WITH CBC
SECTION 11B-1008.2.6 AS FOLLOWS:
• GROUND SURFACES SHALL BE INSPECTED AND MAINTAINS
REGULARLY AND FREQUENTLY TO ENSURE CONTINUED
COMPLIANCE WITH ASTM F 1951.
• GROUND SURFACES LOCATED WITHIN USE ZONES SHALL
COMPLY WITH ASTM F 1292 (1999 EDITION OR 2004 EDITION).
A#04-107827
APP. INC:
REVIEWED FOR
SS FLS ACS
DATE:
IDENTIFICATION STAMP
DIV. OF THE STATE ARCHITECT
04-124690
| G-001 - COVER SHEET |
| AS101 - OVERALL SITE PLAN |
| AS102 - ENLARGED SITE PLAN |
| AS103 - ENLARGED SITE PLAN |
File details come from the government source that posted it. Updated .