Technical Exhibit E- Solicitation W91151-25-R-A009 Water Wash System Diagram.pdf

PDF 152 KB Posted

Attached to
Kitchen Hood Cleaning, Preventive Maintenance and Repair
Solicitation number
W91151-25-R-A009
Issued by

About this file

This technical exhibit is a detailed diagram of a Water Wash System for a kitchen hood installation. The diagram illustrates the comprehensive components and connections for a typical water wash hood system, including key elements such as a waterwash hood, exhaust duct collar, junction box with hood lights, control station, and various water supply lines. The diagram specifies optional and standard connections including hot and cold water supplies, detergent lines, a vacuum breaker, and electrical requirements of 115 VAC 20 AMP service. The technical exhibit notes that internal components are factory piped and wired, while external piping and wiring will be completed by others, providing a clear schematic for installation and system configuration.

View the file

Other files

File Type Posted
Combined Synopsis Solicitation W91151-25-R-A009 v7 17 JUL 2025.docx DOCX document
Combined Synopsis Solicitation W91151-25-R-A009- 04 JUN 2025 KO REVIEWED with Corrections v7.pdf PDF
Kitchen Hood Preventive Maintenance Services Follow-On Questions and Answers JUL 2025.pdf PDF
Combined Synopsis Solicitation for W91151-25-R-A009 Kitchen Hood Cleaning Preventive Maintenance and Repair.pdf PDF
Attachment 2 - Solicitation W91151-25-R-A009 Kitchen Hoods PWS.pdf PDF
Technical Exhibit B - Solicitation W91151-25-R-A009 Roof Descriptions.xlsx XLSX spreadsheet
Techical Exhibit C - Solicitation W91151-25-R-A009 Monthly Schedule Example.xlsx XLSX spreadsheet
Technical Exhibit A - Solicitation W91151-25-R-A009 Exhaust Hoods Inventory List 4 Jan 2024.xlsx XLSX spreadsheet
Attachment 3 - Solicitation W91151-25-R-A009 Wage Determination Rev.27.pdf PDF
Techical Exhibit F - Soicitation W91151-25-R-A009 Hazardous Material Authorization Request.pdf PDF
Technical Exhibit K - Solicitaion W91151-25-R-A009 PM Replacement Parts.xlsx XLSX spreadsheet
Combined Synopsis Solicitation W91151-25-R-A009 Kitchen Hood Cleaning Preventive Maintenance and Repair.pdf PDF
Technical Exhibit D - Solicitation W91151-25-R-A009 Maintenance Report.xlsx XLSX spreadsheet
Attachment 1- Solicitation W9115125RA009 Contract Clauses.pdf PDF
Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Waterwash Hood

Junction Box - Hood Lights

Exhaust Duct Collar

Drain Pipe

Waterwash Control Station

Hot Water Supply to Control Station

Optional Cold Water Supply to Control Station

Vacuum Breaker

Detergent Line

Hot Water/Detergent to Hood

Detergent Check Valve

Optional Continuous Cold Water Mist Supply Line

Internal components of hood and control station are factory piped and wired. All external piping and wiring is by others.

115 VAC 20 AMP service

Fire Sup. System NC Switch

Fan Control Center

Opt. Solenoid Valve for Seq. Wash

Wiring to:

Water Wash System

Typical Installation:

Fig. 1

File details come from the government source that posted it. Updated .