Technical Exhibit B - Solicitation W91151-25-R-A009 Roof Descriptions.xlsx
XLSX spreadsheet 12 KB Posted
- Solicitation number
- W91151-25-R-A009
About this file
The document is a Technical Exhibit B detailing roof descriptions for multiple facilities associated with Solicitation W91151-25-R-A009 for Kitchen Hood Cleaning services at Fort Cavazos, Texas. The exhibit comprehensively catalogs 50+ buildings with specific roof characteristics, including roof types (flat gravel, standing seam metal, sloped shingled), parapet wall heights, and roof access methods. Most facilities lack permanent anchor points and require ladder access, with some having internal mechanical room ladders. The document also provides examples of approved fall protection methods for different roof types, such as warning line systems, water-filled counterweight anchors, roof clamps, and mobile fall protection carts.
The related federal contract opportunity is a 100% Small Business Set-Aside Firm-Fixed-Price Indefinite Delivery/Indefinite Quantity (IDIQ) contract for kitchen hood cleaning, preventive maintenance, and repair services. The contract will span 60 months, covering locations throughout Fort Cavazos, including Main Cantonment, North Fort Cavazos, West Fort Cavazos, and Belton Lake Outdoor Recreational Area. The solicitation closes on 15 JUL 2025 at 1:00 PM Central Time, with questions accepted until 10 JUL 2025. The contract's NAICS code is 561790, with a business size standard of $9M, and the government intends to award without discussions.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet2
| ROOF DESCRIPTIONS | |
| 113 | This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof or pre-designed roof access. |
The Contractor will require a ladder to access the roof.
| 333 | This facility has a standing seam sloped metal roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof. |
| 1937 | This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof. |
| 4612 | This facility has a flat roof with gravel and has no parapet walls. There are not any permanent anchor points on the roof. This building has roof access by ladder. |
| 5764 | This facility has a standing seam sloped metal roof with no parapet walls. There are not any permanent anchor points on the roof. The building has roof access from mezzanine area. |
| 7081 | This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof. |
| 9205 | This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof. The building has a roof access ladder inside mechanical room. |
| 12007 | This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof. The building has a roof access ladder inside mechanical room. |
| 20114 | Sloped shingled roof, no parapet walls. There are not any permanent anchor points on the roof. The Contractor will require a ladder to access the roof. |
| 20137 | Sloped shingled roof, no parapet walls. There are not any permanent anchor points on the roof. The Contractor will require a ladder to access the roof. |
| 20139 | Sloped shingled roof, no parapet walls. There are not any permanent anchor points on the roof. The Contractor will require a ladder to access the roof. |
| 21020 | This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof. The building has a roof access ladder inside mechanical room. |
| 23025 | This facility has a standing seam sloped metal roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof. |
| 34002 | This facility has a flat roof with gravel and has parapet walls that are 42 inches in height or greater. There are not any permanent anchor points on the roof. The building has a roof access ladder inside mechanical room. |
| 39041 | This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof. The building has a roof access ladder inside mechanical room. |
| 41015 | This facility has a standing seam sloped metal roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof. |
| 48303 | This facility has a standing seam sloped metal roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof. |
| 49010 | This facility has a standing seam sloped metal roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof. |
| 52024 | This facility has a standing seam sloped metal roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof. |
| 52940 | This facility has a standing seam sloped metal roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof. |
| 52943 | This facility has a standing seam sloped metal roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof. |
| 56425 | This facility has a sloped shingled roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof. |
| 56447 | This facility has a sloped shingled roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof. |
| 56471 | This facility has a sloped shingled roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof. |
| 56519 | Flat roof with gravel, has parapet walls less than 42 inches tall. No permanent anchor points on roof. The Contractor will require a ladder to access the roof. |
| 70004 | This facility has a standing seam sloped metal roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof. |
| 70020 | This facility has a standing seam sloped metal roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof. |
| 90145 | This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof. |
| 91226 | This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof. The building has a roof access ladder inside mechanical room. |
| 4615 | This facility has a flat roof with gravel and has no parapet walls. There are not any permanent anchor points on the roof. The Contractor will require a ladder to access the roof. |
| 5782 | This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof. |
| 36000 | The exhaust fans are located on the side of the facility and not on the roof. |
| 40001 | The exhaust fan is located on the side of the facility not on the roof. |
| 41018 | This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof. The building has a roof access ladder inside mechanical room. |
| 48830 | This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof. The Contractor will require a ladder to access the roof. |
| 52019 | This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof. The Contractor will require a ladder to access the roof. |
| 56320 | This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof. The building has a roof access ladder inside mechanical room. |
| 85018 | This facility has a standing seam sloped metal roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof. |
| 118 | Type 2 Hoods do not require roof access to clean. |
| 4250 | Type 2 Hoods do not require roof access to clean. |
| 9401 | Type 2 Hoods do not require roof access to clean. |
| 33012 | Type 2 Hoods do not require roof access to clean. |
| 50000 | Type 2 Hoods do not require roof access to clean. |
| EXAMPLES OF APPROVED FALL PROTECTION METHODS: | |
| Flat Roofs-Warning lines system, Water filled neoprene counterweight fall arrest anchor system, weighted temporary anchor point, guardrail systems. | |
| Standing Seam Sloped Metal Foofs- Standing seam roof clamps with self retracting lifeline, mobile fall protection cart. | |
| Sloped Shingled Roofs- Mobile fall protection cart. |