This is a Technical Evaluation Criteria document for the National Institute of Biomedical Imaging and Bioengineering (NIBIB) acquisition of an HZ-12 Centrifugal Barrel Finishing Machine or equivalent. The evaluation will use a Best Value methodology, with all technical requirements being mandatory and pass/fail in nature. Any failure to meet a requirement results in an Unacceptable rating.
The required system must be a high-energy centrifugal barrel finishing machine suitable for small-scale lab or production environments with approximately 12 liters (0.42 cubic feet) total capacity. The system must include heavy-duty steel, all-welded construction with a powder-coated finish; four removable barrels with polyurethane linings; polyurethane-lined barrels (minimum thickness specified); 120V single-phase power with approximately 1 HP motor and variable speed drive control; an integrated cycle timer (0-100 hour range); and safety features including door interlock and automatic braking. The equipment must fit within specified lab footprint dimensions (~32"W x 30"D x 55"H), be compatible with standard lab electrical infrastructure, and be delivered fully assembled within 4-6 weeks. Required inclusions are vendor-provided virtual training at no cost, minimum 1-year warranty on wearable components, up to 3-year warranty on structural components, and manufacturer support for repairs and replacement parts. All required consumables (media and compounds) must be included for full operation at delivery.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Combined_syn_sol 3 Mass Fishing.docx | DOCX document | |
| SOW_MFI_HZ-12_CentrifugalBarrelFinisher.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Technical Evaluation Criteria
National Institute of Biomedical Imaging and Bioengineering (NIBIB) Acquisition of HZ-12 Centrifugal Barrel Finishing Machine or Equal
Evaluation Methodology:
Proposals will be evaluated using a Best Value methodology.
Offerors must meet all technical requirements without exception. Failure to meet any requirement will result in an Unacceptable rating.
A. Technical (Pass/Fail – Mandatory)
| 1. System Performance |
| Acceptable |
| Unacceptable |
Must be a high-energy centrifugal barrel finishing machine suitable for small-scale lab or production environments.
Must provide sufficient finishing capability for precision parts.
Must have a total capacity of approximately 12 liters (0.42 cubic feet).
| 2. System Configuration & Completeness |
| Acceptable |
| Unacceptable |
Must include all required components for full operation at delivery:
Base machine with standard pushbutton control panel.
Four (4) removable barrels with lids.
Required consumables (media and compounds for operation).
| 3. Mechanical & Construction Requirements |
| Acceptable |
| Unacceptable |
Must include:
Heavy-duty steel, all-welded construction.
Reinforced frame for durability.
Powder-coated, scratch-resistant finish.
Barrels lined with polyurethane (minimum ¼” thickness).
| 4. Electrical & Operational Requirements |
| Acceptable |
| Unacceptable |
Must include:
120V single-phase power (or equivalent).
Approximately 1 HP motor.
Variable speed drive control.
Integrated cycle timer (0-100 hour range).
| 5. Safety Features |
| Acceptable |
| Unacceptable |
Must include:
Safety Interlock preventing operation when door is open.
Automatic braking system when cycle ends or door is opened.
Safe operational design compliant with standard lab safety practices.
| 6. Compatibility & Integration |
| Acceptable |
| Unacceptable |
Must:
Fit within lab footprint (~32”W x 30”D x 55”H).
Be compatible with standard lab electrical infrastructure.
| 7. Installation & Training |
| Acceptable |
| Unacceptable |
Must include:
Equipment delivered fully assembled.
Vendor-provided virtual training at no cost.
Optional onsite support available if required.
| 8. Warranty & Technical Support |
| Acceptable |
| Unacceptable |
Must include:
Minimum 1-year warranty on wearable components.
Up to 3-year warranty on structural components.
Manufacturer support for repairs and replacement parts.
| 9. Delivery & Lead Time |
| Acceptable |
| Unacceptable |
Must:
Provide delivery within approximately 4-6 weeks after order.
Include shipping and coordination details.
Manufacturer support for repairs and replacement parts.
Technical Evaluation Rating Definitions
| Rating |
| Definition |
| Acceptable: |
| Meets all requirements with clear evidence; low to moderate risk. |
| Unacceptable: |
| Fails any requirement or lacks sufficient detail. |