Tech Data - PGC 36096 -ImprovedDBwCS - 04.04.23.pdf

PDF 779 KB Posted

Attached to
Improved and Regular Duffel Bag Federal contract opportunity
Solicitation number
SPE1C1-23-R-0094
Issued by
Defense Logistics Agency Troop Support Clothing and Textiles

View the file

Other files for this federal contract opportunity

Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Technical and Packaging Data

PGC36096 - Duffel Bag (with Compression Straps)

Updated: 4/4/2023

Bag, Duffel, Compressions Straps shall be made in accordance with MIL-DTL-32661.

The following drawings may be used for reference only:

2-3-0595 -Bag, Duffel Assembly

2-3-0599 -End Pocket Assembly, Bag, Duffel

2-3-0601 -Shoulder Strap Assembly, Bag, Duffel

2-3-0603 -Identification/Label, Bag, Duffel

2-4-0101 -Side Release Fastener, 1-Inch

In the case of conflict between specification and drawing, the specification (MIL-DTL-32661) shall govern.

Standard sample for Cloth, Nylon Duck, Water Repellent Treated and Coated conforming to Type I, Class

3, Style A of MIL-DTL-32439B is available on roll no. 3933 and is for shade only.

Inspection shall be as follows:

ANZI Z1.4

Dimensional S-2 6.5

Visual Level II 1.0

Palettization S-I 6.5

Prep S-3 2.5

Interim changes to MIL-DTL-32661:

ADDITIONAL INFORMATION FOR MIL-DTL-32661 & MIL-DTL-32439B:

PRODUCTION SAMPLES:

All production samples being sent to DLA Troop Support shall be randomly pulled by the QAR and accompanied by a DD1222. This is for any samples requested by DLA or samples being sent by the

Prime.

SHADE SWATCHING EVALUATION REQUIREMENT

52.246-9031

(A) SAMPLING: NOTWITHSTANDING ANY CURRENT PROVISIONS OF THE FABRIC

SPECIFICATION, THE FOLLOWING SHED EVALUATION SHALL APPLY TO THIS

SOLICITATION. A 4X12 INCH SHADE SWATCH WILL BE CUT BY THE CONTRACTOR FROM

THOSE PIECES OR ROLLS SELECTED BY THE GOVERNMENT REPRESENTATIVE, IN

ACCORDANCE WITH THE FOLLOWING TABLE:

LOT SIZE (PIECES) PIECES TO BE SAMPLED

1 TO 8 EACH PIECE

9 TO 25 8 PIECES

26 TO 90 20 PIECES

91 TO 160 32 PIECES

OVER 160 PIECES 1 OF EVERY 5 PIECES

THE SWATCHES SHALL BE IDENTIFIED AND SUBMIT TO THE DLA TROOP SUPPORT

LABORATORY FOR SHADE EVALUATION. IF ONE OR MORE OF THE SHADE SWATCHES

ARE FOUND UNACCEPTABLE, THE ENTIRE LOT SHALL BE REJECTED. A LOT THAT WAS

REJECTED FOR SHADE SHALL BE SCREENED AND ALL DEFECTIVE PIECES IN THE LOT

SHALL BE REMOVED BEFORE SUCH A LOT IS RESUBMITTED. RESUBMITTED LOTS SHALL

AGAIN BE SUBJECTED TO THE SAMPLING AND SHADE EVALUATION PRESCRIBED

HEREIN. THIS REQUIREMENT DOES NOT NEGATE THE CONTACTOR'S RESPONSIBILITY TO

PERFORM SHADE EVALUATION PRIOR TO THE SUBMITTAL OF A LOT TO THE

GOVERNMENT.

(B) WHEN SECTION 3 OF THE FABRIC SPECIFICATION CONTAINS A SPECIFIC

REQUIREMENT FOR UNIFORMITY OF SHADE AND WHEN THE STANDARD SAMPLE IS

REFERENCED FOR UNIFORMITY OF SHADE, THE SWATCHES SUBMITTED IN

ACCORDANCE WITH (A) ABOVE SHALL ALSO BE EVALUATED FOR UNIFORMITY OF

SHADE.

(C) THE CONTRACTOR SHALL TRANSMIT THE SWATCHES TO:

DLA PRODUCT TESTING CENTER ANALYTICAL

700 ROBBINS AVENUE

PHILADELPHIA, PA 19111

ATTN: BLDG 5D

EMAIL: jamie.hieber@dla.mil

PHONE: 215-737-3265

THE LETTER SHALL INDICATE "FOR GOVERNMENT SHADE APPROVAL" AND CONTAIN

THE FOLLOWING INFORMATION:

(1) NAME OF PRIME CONTRACTOR.

(2) CONTRACT NUMBER.

(3) NOMENCLATURE.

(4) GOVERNMENT INSPECTION LOT NUMBER.

(5) NUMBER OF SWATCHES BEING SUBMITTED.

(6) QAR'S NAME.

(7) NAME AND ADDRESS OF THE QAR'S BASE PLANT.

(8) PIECE NUMBER OF STANDARD SAMPLE CITED IN CONTRACT.

(9) TALLY LIST WITH PIECE NUMBERS (NOT APPLICABLE TO CASE SWATCHING).

(D) IF ANY SWATCHES ARE REJECTED BY THE DLA PRODUCT TESTING CENTER--

ANALYTICAL FOR SHADE, THOSE PIECES FROM WHICH THE REJECTED SWATCHES WERE

CUT WILL BE REMOVED FROM THE LOT. EACH PIECE ACCEPTABLE FOR SHADE FROM

WHICH A SHADE SWATCH HAS BEEN REMOVED SHALL BE CUT BY THE CONTRACTOR

FROM SELVAGE TO SELVAGE SO THAT THERE WILL BE NO EVIDENCE OF THE SHADE

SWATCH CUT-OUT. THE PORTION REMOVED SHALL NOT BE INCLUDED IN THE

YARDAGE INDICATED ON THE PIECE TICKET.

(E) IF THE CONTRACTOR REWORKS AND RESUBMITS PIECES ORIGINALLY REJECTED FOR

SHADE OR FINISH, IT SHALL NOT COMBINE THE REJECTED PIECES WITH NORMAL

PRODUCTION OR WITH LOTS REJECTED FOR OTHER CAUSES. SUCH PIECES SHALL BE

COMBINED TO FORM ONE RESUBMITTED LOT. EACH PIECE SHALL RETAIN ITS ORIGINAL

PIECE NUMBER, SUFFIXED WITH AN "X". THE LOT NUMBER SHALL ALSO BE SUFFIXED

WITH AN "X".

ADDITIONAL INFORMATION FOR L-P-378:

L-P-378 IS HEREBY CANCELLED AND REPLACED

BY A-A-3174 10/15/98

A-A-3174 DATED 15 OCTOBER 1998, IS HEREBY

CANCELED WITHOUT REPLACEMENT.

A-A-3174 NOTICE 2 DATED JULY 25, 2000 NOTICE OF

REINSTATEMENT. COMMERCIAL ITEM DESCRIPTION

A-A-3174, DATED OCTOBER 15, 1998, IS HEREBY

REINSTATED AND MAY BE USED FOR ACQUISITION.

INTERIM CHANGES TO A-A-55126B,

THE FOLLOWING CHANGES ARE FOR ALL CURRENT, PENDING AND FUTURE

PROCUREMENTS OF THE SUBJECT DOCUMENT UNTIL SUCH TIME AS THE DOCUMENT IS

AMENDED OR REVISED.

PAGE 4. TABLE I, PHYSICAL REQUIREMENTS, CHARACTERISTIC, SHEAR

STRENGTH,DELETE LBS/SQ INCH (MIN), ADD SHEAR STRENGTH, LBS/2 SQ INCH (MIN).

PAGE 5 TABLE II, PHYSICAL REQUIREMENTS; CHARACTERISTIC, LENGTH

DIMENSIONAL STABILITY, % (MAX); LOOP, ALL CLASSES DELETE .0; ADD ALL CLASSES

4.0.

PAGE 7, Paragraph 3.10.2, Change the following title of paragraph from: "Fray resistance of Universal

Camouflage Shades" and replace with "Fray resistance of Camouflage Prints"

PAGE 14, Paragraph 7.3.4 Change the following title of paragraph from: Fray resistance for Universal

Camouflage Shades." and replace with "Fray resistance for Camouflage Prints."

DELETE

ADDITIONAL INFORMATION FOR A-A-55634A, 23 MARCH 2004:

SPECIAL NOTE!! ALL SLIDE FASTENERS USED ARE TO BE MEASURED FROM "STOP TO

STOP". RECOMMEND THAT THIS MEASUREMENT BE TAKEN RANDOMLY BEFORE SLIDE

FASTENERS ARE SEWN TO THE ITEMS, COVERALL, OR ANY ITEM REFERRED TO IN THE

SOLICITATION. "THE QAR WILL REJECT ANY SLIDE THAT IS NOT LAYING FLAT AFTER IT

IS SEWN INTO/ONTO AN ITEM." SPECIAL INFO ON ITEMS THAT UTILIZE SLIDE

FASTENERS IS GIVEN BY "ALL USING MILITARY PERSONNEL".

INCLUDE ZT101 OBJECT TEXT ID ST

MIL-DTL-32075: LABEL FOR CLOTHING, EQUIPAGE,

AND TENTAGE, GENERAL USE REPLACES DDD-L-20

(Ref. T0451 - June 19, 2007)

INTERIM SPECIFICATION CHANGES TO MIL-DTL-32075:

PAGE 4, PARA. 3.3.5, AFTER "TYPE III OR IV, CLASS 4 OF" DELETE "DDD-L-20" AND

REPLACE "MIL-DTL-32075,".

PAGE 6, TABLE I, "PHYSICAL REQUIREMENTS OF THE

TYPE VI FINISHED LABEL." UNDER "TEARING

STRENGTH" DELETE: "(LB.) MINIMUM" AND

SUBSTITUTE: "(GNS) MINIMUM."

PAGE 12, PARA 3.3.2.17, AFTER "NSN" ADD

"AND THE UNIVERSAL PRODUCT CODE (UPC)

SUPPLIED BY THE GOVERNMENT, FOR ALL NSNs."

ADDITIONAL INFORMATION FOR MIL-PRF-5038:

ALL STANDARD SAMPLE INFORMATION WILL STILL APPLY.

STANDARD SAMPLES ARE AS FOLLOWS:

TAN 380, TYPE III, ROLL #3497, FOR SHADE, APPEARANCE AND COLORFASTNESS.

TAN 380, TYPE II, ROLL #3498, FOR SHADE, APPEARANCE AND COLORFASTNESS.

BLACK 375, TYPE III, ROLL #3443, FOR SHADE, APPEARANCE AND COLORFASTNESS.

OLIVE DRAB 7, TYPE IV, ROLL #3012, FOR SHADE, FINISH AND COLORFASTNESS.

CAMOUFLAGE GREEN 483, TYPE II, ROLL #3484, FOR SHADE, APPEARANCE AND

COLORFASTNESS.

CAMOUFLAGE GREEN 483, TYPE III, ROLL #3485 FOR SHADE, APPEARANCE AND

CAMOUFLAGE GREEN 483, TYPE IV, ROLL #3486, FOR SHADE, APPEARANCE AND

STANDARD SAMPLE FOR FOLIAGE GREEN 504 IS MIL-C-44436, ROLL #3729 (THE FOLIAGE

GREEN 502 AREA OF THE PATTERN).

STANDARD SAMPLE FOR DESERT SAND 503 IS MIL-C-44436, ROLL #3729 (THE DESERT

SAND 500 AREA OF THE PATTERN).

FOLIAGE GREEN 504/DESERT SAND 503 IS TO BE USED AS SPECIFIED BY CONTRACT. THIS

APPLIES TO TYPE III.

INTERIM SPECIFICATION CHANGES TO MIL-W-5664D:

PARA. 3.3.1 - DELETE IN ITS ENTIRETY AND SUBSTITUTE: "3.3.1 WEAVE CONSTRUCTION.

THE WEAVE FOR ALL TYPES AND CLASSES MAY BE SUPPLIED IN EITHER SHUTTLE OR

SHUTTLELESS LOOM CONSTRUCTION.

PARA. 3.7, SENTENCE 2, DELETE IN ITS ENTIRETY AND SUBSTITUTE "TYPE II SHALL BE

CAMOUFLAGE GREEN 483.

PARA. 4.6.1.1 YARD-BY-YARD EXAMINATION, CONTINUED ON PAGE 6, LINE 2, DELETE

"2.5" AND SUBSTITUTE "1.5.". LINE 3, DELETE "6.5" AND SUBSTITUTE "4.0"

TABLE II - DELETE THE DEFECT FOR "YARNS (FILLING)" ENTIRELY.

PARA. 4.6.3 - DELETE IN ITS ENTIRETY.

STANDARD SAMPLE FOR FOLIAGE GREEN 504, WEBBING, TEXTILE, ELASTIC, IS

IDENTIFIED AS ROLL NO. 3743, REFERENCED FOR SHADE ONLY.

STANDARD SAMPLE FOR CAMOUFLAGE GREEN 483 IS IDENTIFIED AS ROLL NO. 3523,

REFERENCED FOR SHADE ONLY.

ADDITIONAL INFORMATION FOR MIL-W-17337:

THE WEBBING, TEXTILE, WOVEN NYLON SHALL BE

MADE IN ACCORDANCE WITH PN 70167 M11637-6,

INTERIM CHANGES TO MIL-W-17337

PARA. 3.4, ADD NEW COLOR: "E. CAMOUFLAGE GREEN

483 NO, 34094 OF FED-STD-595 (SEE 6.7)". AFTER

INTERIM STANDARD SAMPLE FOR FOLIAGE GREEN 504 IS

IDENTIFIED AS ROLL #3721 (THE FOLIAGE GREEN 502

AREA OF THE PATTERN, AND REFERENCED FOR SHADE

ONLY. FOLIAGE GREEN 504 IS TO USED AS SPECIFIED

BY CONTRACT.

ADD F. FOLIAGE GREEN 504

PARA. 3.4.3, ADD NEW PARAGRAPH:

"3.4.3.1 SPECTRAL REFLECTANCE. FINISHED

CAMOUFLAGE

GREEN 483 WEBBING GREATER THAN 1-1/4" IN

WIDTH SHALL MEET THE FOLLOWING SPECTRAL

REFLECTANCE

FACTORS (IN PERCENT) FOR THE VISIBLE/NEAR

-INFRARED WAVELENGTH RANGE, 600 TO 860 C1040

NANOMETERS (NM), WHEN TESTED

AS SPECIFIED IN 4.5.

% REFLECTANCE % REFLECTANCE

WAVELENGTH(NM) MIN. MAX. WAVELENGTH (NM) MIN.MAX

600 3 10 740 7 52

620 3 10 760 11 60

640 3 10 780 17 64

660 3 11 800 24 67

680 3 15 820 32 70

700 3 28 840 37 75

720 5 40 860 40 78"

TABLE IV, AFTER "COLORFASTNESS TO: CROCKING",

ADD THE FOLLOWING UNDER THEIR RESPECTIVE COLUMNS

"SPECTRAL REFLECTANCE 3.4.4 4.5.1.5"

AFTER 4.5.1.4, ADD NEW PARAGRAPH:

"4.5.1.5 SPECTRAL REFLECTANCE MEASUREMENTS IN

THE VISIBLE/NEAR INFRARED. SPECTRAL REFLECTANCE

DATA FOR CAMOUFLAGE GREEN 483, SHALL BE OBTAINED

FROM 600 TO 860 NANOMETERS (NM), AT 20 NM

INTERVALS ON A SPECTROPHOTOMETER (SEE 6.8)

RELATIVE TO A BARIUM SULFATE STANDARD, THE PRE-

FERRED WHITE REFERENCE STANDARD. OTHER WHITE

REFERENCE MATERIAL MAY BE USED, PROVIDED THEY

ARE CALIBRATED TO ABSOLUTE WHITE; E.G., HALON,

MAGNESIUM OXIDE, OR VITROLITE TILES (SEE 6.9).

THE SPECTRAL BANDWIDTH NM SHALL BE LESS THAN 26

NM AT 860. REFLECTANCE MEASUREMENTS SHALL BE

MADE BY EITHER THE MONOCHROMATIC OR POLYCHRO-

MATIC MODE OF OPERATION. WHEN THE POLYCHROMATIC

MODE IS USED, THE SPECTROPHOTOMETER SHALL OPER-

ATE WITH THE SPECIMEN DIFFUSELY ILLUMINATED WITH

THE FULL EMISSION OF A SOURCE THAT SIMULATES

EITHER CIE SOURCE OR CIE SOURCE D65. THE

SPECIMEN SHALL BE MEASURED AS

A SINGLE LAYER BACKED

WITH TWO LAYERS OF THE SAME FABRIC AND SHADE.

READINGS SHALL BE TAKEN ON A MINIMUM OF TWO

DIFFERENT AREAS, AND THE DATA AVERAGED. THE

SPECIMEN SHALL BE VIEWED AT AN ANGLE NO

GREATER THAN 10 DEGREES FROM NORMAL, WITH THE

SPECULAR COMPONENT INCLUDED. PHOTOMETRIC

ACCURACY OF THE SPECTROPHOTOMETER SHALL BE

WITHIN 1 PERCENT AND WAVELENGTH ACCURACY

WITHIN 2 NM. THE STANDARD APERATURE SIZE USED IN

THE COLOR MEASUREMENT DEVICE SHALL BE 1.0 TO

1.25 INCHES IN DIAMETER. WHEN THE MEASURED

REFLECTANCE VALUES AT FOUR OR MORE WAVELENGTHS

DO NOT MEET THE REQUIREMENTS SPECIFIED IN

3.4.4, IT SHALL BE A TEST FAILURE.".

AFTER 6.6, ADD NEW PARAGRAPHS:

"6.7 COLOR. THE ARMY HAS REPLACED THE USE OF

OLIVE DRAB 7 WITH CAMOUFLAGE GREEN 483. ANY ARMY

END ITEM WHICH PREVIOUSLY REQUIRED THE OLIVE

DRAB 7 COLOR SHALL USE CAMOUFLAGE GREEN 483.

6.8 SPECTROPHOTOMETERS. SUITABLE SPECTROPHO-

TOMETERS FOR MEASURING SPECTRAL REFLECTANCE

IN THE VISIBLE/NEAR-INFRARED ARE DIANO HARDY,

DIANO MATCH SCAN, HUNTER D54P-IR, AND MACBETH

1500 WITH IR OPTION.

6.9 WHITE STANDARD. BARIUM SULFATE OF SUITABLE

QUALITY FOR USE AS A WHITE REFERENCE STANDARD IS

AVAILABLE FROM THE EASTMAN KODAK COMPANY. THE

SAME SOURCE HAS AVAILABLE, MAGNESIUM REAGENT

(RIBBON) AND HALON. SUITABLE TILES CAN BE OB-

TAINED FROM THE NATIONAL BUREAU OF STANDARDS OR

THE INSTRUMENT MANUFACTURERS.

6.10 DYE COMBINATION FOR CAMOUFLAGE GREEN 483:

ACID BLUE 171 ACID ORANGE 162".

ADDITIONAL INFORMATION FOR MIL-G-16491:

MIL-G-16491F IS CANCELLED - REPLACED BY NASM 16491.

ADDITIONAL INFORMATION FOR ANSI/ASQC Z1.4:

NOTE: THE MOST RECENT VERSION OF THIS DOCUMENT SHOULD BE USED.

APPLICATION FOR COPIES SHOULD BE ADDRESSED TO:

AMERICAN SOCIETY FOR QUALITY

600 NORTH PLANKINTON AVENUE

MILWAUKEE, WISCONSIN 53203

(Ref. T0795 - May 17, 2006)

ASTM D 751 STANDARD TEST METHODS FOR

. COATED FABRICS

. 28 APRIL 1989.

ASTM D 3775 FABRIC COUNT OF WOVEN FABRIC

. 3 OCTOBER 1994.

ADDITIONAL INFORMATION FOR ASTM-D3776:

NO ADDITIONAL INFORMATION FOLLOWS.

ADDITIONAL INFORMATION FOR ASTM-D5034:

NO ADDITIONAL INFORMATION FOLLOWS.

ADDITIONAL INFORMATION FOR ASTM-D-6193(2004)OR LATEST VERSION:

NO ADDITIONAL INFORMATION FOLLOWS.

PACKAGING & INSPECTION DATA:

Marking shall be in accordance with MIL-STD-129.

15 Duffel Bags shall be packed in a fiberboard shipping container conforming to ASTM-D-5118, Type

CF, Style RSC, Grade 275, variety SW, Class domestic, with a double wall liner. Any commercial closure method cited in ASTM-D-1974 is acceptable except stapling.

If not using an RFID hangtag containing printed requirements below (barcode label):

Each bag shall have a barcode label conforming to Type VIII, Class 17 of MIL-DTL-32075. The bar coding element shall be a 13 digit national stock number (NSN). There shall be a 12 digit UPC number assigned for all NSNs by the contracting activity. The initials "UPC" must appear beneath the code. The bar code for NSN and UPC type shall be a medium to high density and shall be located so that it is completely visible on the garment when it is folded and/or packaged as specified and so it causes no damage to the garment. The UPC code must be placed on all shipping cartons on which the NSN appears.

RFID HANGTAG:

An RFID inlay shall be individually attached to each item.

The RFID inlay shall be passive Gen2 with a frequency range between 860 and 960 MHz. The RFID antenna shall be Avery/Dennis AD222 or comparable with ISO/IEC 18000-6C EPC global Class1 Gen2

Protocol and an EPC memory allocation containing a 96 bit EPC Number. The data linking the EPC number to the NSN and quantity unit pack shall be exportable to VIM/ASAP. The bar code and the human readable version of the EPC Number shall be printed under the RFID inlay.

The RFID tag shall be examined for the defects listed below:

-RFID Inlay omitted

-RFID Inlay not secure

-RFID Inlay not readable with RFID scanner RFID Inlay or configuration not as specified Barcode of the

EPC number omitted or not readable with barcode scanner Human readable version of the EPC number omitted or not readable

The manual document "Item-Level Passive RFID Technology Manufacturer's Information Guide" provides guidance on RFID implementation and is available from the contracting officer.

SIGNIFICANT NOTE - "PALLETIZATION IS REQUIRED FOR THESE SUPPLIES".

NOTE: THE FOLLOWING APPLIES TO ALL NON-MANUFACTURED WOOD PACKAGING

MATERIALS:

"All Wood Packaging Material (WPM) acquired by DOD must meet requirements of International

Standards for Phytosanitary Measures (ISPM) 15, "Guidelines for Regulating Wood Packaging Materials in International Trade." DOD shipments inside and outside of the United States must meet ISPM 15 whenever WPM is used to ship DOD cargo, or when wood is being acquired by DLA for future use as packaging material. WPM is defined as wood pallets, skids, load boards, pallet collars, wooden boxes, reels, dunnage, crates, frame and cleats. Packaging materials exempt from the requirements are materials that have undergone a manufacturing process, such as corrugated fiberboard, plywood, particleboard, veneer, and oriented strand board (OSD). All WPM shall comply with one of the following official quality control programs:

Heat Treatment (HT) or Kiln Dried Heat Treatment (KD HT) in accordance with American Lumber

Standard Committee, Incorporated (ALSC) Wood Packaging Material Program and WPM Enforcement

Regulations (see http://www.alsc.org/; or

All WPM shall include certification/quality markings in accordance with the ALSC or NWPCA standards, as applicable. Markings shall be placed in an unobstructed area that will be readily visible to inspectors. Pallet markings shall be applied to the stringer or block on diagonally opposite sides of the pallet and be contrasting and clearly visible.

All containers shall be marked on a side other than the top or bottom, contrasting and clearly visible. All dunnage used in configuring and/or securing the load shall also comply with ISPM 15 and be marked with an ASLC approved DUNNAGE stamp. Failure to comply with the requirements of this restriction may result in refusal, destruction, or treatment of materials at the point of entry. The Agency reserves the right to recoup from the Contractor any remediation costs incurred by the Government."

PALLET SHALL BE 4 WAY ENTRY, WINGED TYPE. PALLETIZED LOAD DIMENSIONS

SHALL NOT EXCEED 43 INCHES IN LENGTH, 52 INCHES IN WIDTH, AND 54 INCHES IN

HEIGHT (INCLUDING THE PALLET).

THE PALLETIZED LOAD SHALL BE BONDED USING APPROVED COMMERCIAL BONDING

MATERIALS. THE USE OF METAL BANDING, IN SECURING BOXES TO PALLETS, IS

DISCOURAGED. PALLET LOADS SHALL CONTAIN THE SAME NUMBER OF CARTONS, OF

IDENTICAL QUANTITIES, OF ONE NSN, TO THE MAXIMUM EXTENT POSSIBLE.

PALLET LOADS CONTAINING MORE THAN ONE NSN SHALL BE CLEARLY MARKED TO

LIST ALL THE NSN'S CONTAINED IN THE LOAD. NO CARTON SHALL HAVE MORE THAN

ONE NSN. AT THE END OF A SIZE RUN, NO MORE THAN ONE CARTON PER NSN MAY BE

SHORT OR OVER THE SPECIFIED QUANTITY. SAID CARTON SHALL BE CLEARLY

MARKED "SHORT" OR "OVER".

MIL-STD-147 IS REFERENCED FOR PALLETIZED LOADS.

IN ADDITION TO REQUIREMENTS SPECIFIED ABOVE THE FOLLOWING CLAUSE ALSO

APPLIES:

52.247-9012 - REQUIREMENTS FOR TREATEMENT OF WOOD PACKAGING MATERIALS

(WPM) - (JULY 2006)

252.211-7006 - RADIO FREQUENCY IDENTIFICATION (RFID) Required

(ref. T8379; Nov. 08, 2006)

MIL-STD-147 IS HEREBY REINSTATED AS FOLLOWS:

MIL-STD-147E DEPARTMENT OF DEFENSE

16 MAY 2008 STANDARD PRACTICE

PALLETIZED UNIT LOADS

STANDARDS (COMMERCIAL)

ASME-MH1 American Society of Mechanical Engineers (ASME) Pallets, Slip Sheets, and Other Bases

For Unit Loads, for construction of pallets.

MIL-STD-129 CURRENT REVISION UNLESS OTHERWISE SPECIFIED

- DEPARTMENT OF DEFENSE STANDARD PRACTICE

- MILITARY MARKING FOR SHIPMENT AND STORAGE

INTERIM CHANGES:

OMISSION OF MARKINGS ON EXTERIOR SHIPPING CONTAINERS OF ITEMS

IN THE DLA TROOP SUPPORT CLOTHING AND TEXTILE (C&T) DIRECTORATE:

THE NOMENCLATURE AND MANUFACTURER'S NAME (WHEN THE NAME IDENTIFIES THE

MATERIAL) SHALL BE OMITTED FROM ALL EXTERIOR SHIPPING CONTAINERS OF DLA

TROOP SUPPORT C&T ITEMS, REGARDLESS OF MODE OF SHIPMENT.

IF THE MANUFACTURER'S NAME DOES NOT IDENTIFY THE MATERIAL AS BEING

CLOTHING, IT MAY REMAIN. NSNS SHALL BE SHOWN ON ALL SHIPPING CONTAINERS OF

C&T ITEMS, THE PACKING LIST SHALL BE PLACED INSIDE THE LAST CONTAINER TO BE

LOADED FOR EACH SHIPMENT. THE WORDS "PACKING LIST HERE" SHALL BE STENCILED,

NOT HAND LETTERED, ON THE CONTAINER.

ADDITIONAL INFORMATION FOR PPP-B-636:

FEDERAL SPECIFICATION PPP-B-636 DATED JULY 12, 1981, INCLUDING INTERIM FEDERAL

SPECIFICATION PPP-B-636L DATED JANUARY 1, 1991, IS HEREBY CANCELLED, AND

REPLACED WITH ASTM-D-5118, STANDARD PRACTICE FOR FABRICATION OF

FIBERBOARD SHIPPING BOXES, AND ASTM-D-1974, STANDARD PRACTICE FOR METHOD

OF CLOSING, SEALING AND REINFORCING FIBERBOARD SHIPPING CONTAINERS.

Packaging examination. The fully packaged end item shall be examined for the defects listed below. The lot size shall be expressed in units of shipping containers. The sample unit shall be one shipping container fully packaged. The Inspection level shall be S-2 and the AQL, expressed in terms of defects per hundred units, shall be 2.5.

Examine Defect

Marking Omitted; incorrect; illegible, of

(exterior) improper size, location, sequence

& Unit Pack, or method of application.

Materials Any component missing, damaged or not as specified.

Workmanship Inadequate application of components, such as: incomplete closure of container flaps, loose strapping, improper taping, or inadequate stapling. Bulged or distorted container.

Contents Number of intermediate containers per shipping container is more or less than required.

Number of items per container is more or less than required.

Palletization examination. The fully packaged and palletized end items shall be examined for the defects listed below. The lot size shall be expressed in units of palletized unit loads. The sample unit shall be one palletized unit load, fully packaged.

The Inspection level shall be S-1 and the AQL, expressed in terms of defects per hundred units, shall be

6.5.

Examine Defect

Finished Length, width or height exceeds Dimensions specified maximum requirement.

Palleti- Pallet pattern not as specified.

zation Interlocking of loads not as specified. Load not bonded with required straps as specified.

Weight Exceeds maximum load limits.

Marking Omitted; incorrect; illegible;

of improper size, location, sequence or method of application.

DRAWINGS, BAG, DUFFEL, IMPROVED MIL-DTL-32661

You may obtain copies of Specifications, Patterns and Drawings by contacting your Contracting Officer.

The following drawings may be used for reference only:

2-3-0595A -Bag, Duffel Assembly

2-3-0599A -End Pocket Assembly, Bag, Duffel

2-3-0601A -Shoulder Strap Assembly, Bag, Duffel

2-3-0603A -Identification/Label, Bag, Duffel

2-4-0101A -Side Release Fastener, 1-Inch

In the case of conflict between specification and drawing, the specification (A-A-55077A) shall govern.

File details come from the government source that posted it. Updated .