SystemSensor_Heat_200Series_DataSheet_A05-0362.pdf

PDF 304 KB Posted

Attached to
FIRE ALARM SYS REPLACEMENT SERVICE - SKAGWAY AK Federal contract opportunity
Solicitation number
140P9723Q0077
Issued by
Department of the Interior National Park Service Alaska Region

About this file

This document contains a product datasheet for SystemSensor's 200 Series intelligent plug-in smoke and heat detectors as well as details for a related federal contract opportunity with the National Park Service.

The datasheet provides specifications for SystemSensor's photoelectric, ionization, and thermal detector models as well as compatible mounting bases and accessories. Detector features include low-profile designs, analog communications, adjustable sensitivity settings, and dual LEDs. Thermal detectors offer fixed-temperature and rate-of-rise heat detection. The opportunity notice is for replacement of the fire alarm system in Skagway, Alaska and seeks contractor support for installation, maintenance, and repair services. The solicitation number is 140P9723Q0077 with responses due to the National Park Service Alaska Region.

View the file

Other files for this federal contract opportunity

Other files attached to FIRE ALARM SYS REPLACEMENT SERVICE - SKAGWAY AK, newest first.
File Type Posted
Sol_140P9723Q0077_Amd_0001.pdf PDF
System-Smoke-Detectors-AppGuide-SPAG91.pdf PDF
SilentKnight_PullStations_DataSheet.pdf PDF
Sol_140P9723Q0077.pdf PDF
B03_DL_WD_2015-5685_Rev_19.pdf PDF
KLGO_Pantheon_Saloon___Red_Front_FireAlarm_plans.pdf PDF
Bldg_Device_Inventories.zip ZIP file
SK-Photo_DataSheet_350118.pdf PDF
SilentKnight_6808_hbt-fire-351608-C.pdf PDF
SilentKnight_SwiftGateway_WSK-WGI_DataSheet.pdf PDF
B08_SOW.pdf PDF
B08_RFQ_Content.pdf PDF
Swift_AVbase_DataSheet.pdf PDF
Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Agency Listings

200 Series Intelligent Low-Profile Plug-In Detectors

The System Sensor 200 Series intelligent plug-in smoke detectors with integral communication provide point location for alarm communication and selective maintenance.

Features

• Sleek, low-profile design

• Analog communications

• Low standby current

• Rotary address switches

• Superior EMI protection

• Dual LEDs for 360° visibility

200Seriessmokedetectorsareintelligent(addressable)detectors
withpointIDcapabilitythatenableeachdetectoraddresstobeset
withdecadeaddressswitchestoprovideexactdetectorlocations.
Thesensitivityof200Seriesdetectorscanbeprogrammedusingthe
controlpanelsoftwaretosuittheenvironment.Inaddition,detector
sensitivityiscontinuallymonitoredandreportedtothepanel.
The System Sensor 2251Bphotoelectricdetector’suniqueoptical
sensingchamberisengineeredtosensesmokeproducedbyawide
rangeofcombustionsources.Dualelectronicthermistorsadd135°F
fixedtemperaturethermalsensingonthe2251TBmodel.The
2251BRisaremotetestcapabledetectorforusewithDNR(W)
ductsmokedetectors.
The Acclimate ™2251TMBphotoelectricdetectorincludesthermal
detectionat135°F.Itusesadvancedonboardsoftwaretocombine
thesignalsfromthephotoandthermalelementstocreateatrue
multi-criteriadetectorcapableofrejectingnuisancesources,butstill
respondingquicklytorealfires.Inaddition,theAcclimatedetector
canadjustitssensitivityaccordingtoitsenvironment.
The 1251Bionizationdetectorincorporatesauniquesingle-source,
dual-chamberdesigntorespondquicklyanddependablytoabroad
rangeoffires.
Boththe 5251B and 5251RBdetectorsuseaninnovativethermistor
sensingcircuittoproduce135°Ffixedandrate-of-risethermaldetection
inlow-profilepackages.The5251Hmodelprovidesfixedhigh-
temperaturedetectionat190°F.Thesethermaldetectorsprovidecost-
effective,intelligentpropertyprotectioninavarietyofapplications.

For exact certification listings for each model, please reference the respective agency Web site.

3825OhioAvenue•St.Charles,IL60174
Phone:800-SENSOR2•Fax:630-377-6495
©2011SystemSensor.
Productspecificationssubjecttochangewithoutnotice.Visitsystemsensor.comfor
currentproductinformation,includingthelatestversionofthisdatasheet.
A05-0362-006•8/11•#2653

Ordering Information Part No. Description

2251B* Photoelectric smoke detector

2251BR* Photoelectricsmokedetector,remotetestcapable,
forusewithDNR(W)ductsmokedetectors

2251TB* Photoelectric smoke detector with thermal

2251TMB* Acclimate™ multi-criteria smoke detector

1251B* Ionization smoke detector

5251B* Fixed temperature thermal detector

5251RB* Rate-of-rise thermal detector

5251H* High temperature thermal detector

Bases

B501* 4” Flangeless mounting base

B501BP* 4” Flangeless mounting base bulk pack

B210LP* 6” Flanged mounting base

B210LPBP* 6” Flanged mounting base bulk pack

B200SR* Standardsounderbase
(compatiblewithB501BHseries)

B200S* Intelligent addressable sounder base

B224RB* Relay base

B224BI* Isolator base

Accessories

SMB600 Surface Mounting Kit (flanged)

F110 Accessory Flange Ring for 6” Base

F110BP Accessory Flange Ring for 6” Base Bulk Pack

F210 Accessory New Smaller Flange Ring for 6” Base

RA100Z Remote LED annunciator

M02-04-01 Detector test magnet

M02-09-00 Telescoping test magnet

XR2B Detector removal tool (T55-127-000 included)

XP-4 Extension for XR2B (5 to 15 ft)

T55-127-000 Detector removal head

BCK-200B Black detector kit (10 pack)**

WCK-2008 White detector kit (10 pack)**

Accessories

200 Series Intelligent Detector Specifications Physical/Operating Specifications

Height 2.0 inches (51 mm)

Diameter 6.1 inches (155 mm) installed in B210LP base; 4.1 inches (104 mm) installed in B501 base

Shipping Weight Heat: 4.8 oz (136 g); Photo/Photo with Heat: 5.2 oz (147 g); Ion: 5.4 oz (153 g)

Operating Temperature Range Ion/Photo:32°Fto120°F(0°Cto49°C)
PhotowithThermal:32°Fto100°F(0°Cto38°C)
Thermal:–4°Fto100°F(–20°Cto38°C)
HighTemperature:–4°Fto150°F(–20°Cto66°C)
UL-Listed Velocity Range Ion:0to1,200fpm(0to6.1m/sec)
Photo/PhotowithThermal:0to4,000fpm(0to20m/sec)(suitableforinstallationinducts)

Operating Humidity Range 10% to 93% non-condensing

Thermal Ratings FixedTemperatureSetpoint:135°F(57°C)
Rate-of-RiseDetection:15°F/min.(8.3°C/min.)
HighTemperatureHeat:190°F(88°C)

Electrical Specifications

Voltage Range 15 to 32 VDC peak

Standby Current (max. avg.) 300µA@24VDC(onecommunicationevery5secondswithLEDenabled)
Photo/PhotowithThermal:300µA@24VDC(onecommunicationevery5secondswithLEDenabled)

LED Current (max.) 6.5 mA @ 24 VDC (on)

RA100Z

Remote LED Annunciator

XR2B

Detector

Removal Tool

Headalsosoldseparately
(partno.T55-127-000)

* Add “A” for ULC listed product (e.g., 2251BA)

**TheBCK-200BandWCK-200BareonlyapplicabletotheB210LPflangedstyle
mountingbaseandmayonlybeusedwith2251B(photoelectric)and1251B
(ionization)smokedetectors.