Surplus Work Sheet.pdf

PDF 110 KB Posted

Attached to
NSN:1680-00-902-2196 NSN 1680-00-872-7023 NOUN:ACTUATOR, ELECTROMEC P/N: R1668-1 P/N: 817T100-1
Solicitation number
SPRTA1-26-Q-0
Issued by

About this file

This is a Surplus Materiel Worksheet (AFMC Form 813) dated April 20, 2026, evaluating the availability and acceptability of surplus government inventory to fulfill procurement needs.

The evaluation concerns a T-38 Flap Actuator (NSN 1680009022196RK, Part Number 817T100-1, CAGE 98889) requested by the Air Force Materiel Command. The evaluator, Dwight C. Caras of 423 SCMS/GUEAB, determined that surplus materiel may be considered to satisfy government requirements. The worksheet indicates that government surplus items in new/unused, new/reconditioned, new/modified, and used/overhauled conditions are all acceptable for consideration. Commercial surplus items in all four condition categories were marked as not acceptable. All acceptable surplus items will be subject to part number and manufacturer verification, prior government ownership confirmation, 100% end item inspection, test and verification, verifiable dimension review, location inspection and testing, initial acceptability testing, and overhaul and certification. The justification for accepting surplus materiel is the urgent need for component carcasses to be overhauled due to high mission-impacting capability (MICAP) demands and carcass constraints. All items will be marked in "K" condition (suspended) prior to shipment pending completion of the evaluation requirements and certification processes.

View the file

Other files

File Type Posted
4438642_TRNSPDATA_REPORT.pdf PDF
4396238_SMW_REPORT.pdf PDF
SPRTA1-26-Q-0435.pdf PDF
4438640_PKGRQMT_REPORT.pdf PDF
Synopsis Memo.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SURPLUS MATERIEL WORKSHEET

DATE

20 APR 2026

I. REQUEST FOR EVALUATION

NSN

1680009022196RK

PART NUMBER

817T100-1

CAGE

98889

APPLICATION

T-38 Flap Actuator

IMS

Caras, Dwight C

OFFICE SYMBOL

423 SCMS / GUEAB

PHONE

405-582-4121

SURPLUS MATERIEL MAY BE AVAILABLE TO FULFILL THE GOVERNMENT'S NEEDS FOR THIS ITEM. AS A RESULT, AN EVALUATION MUST BE PERFORMED

IAW AFMC FAR SUPPLEMENT PART 5352.

THE EVALUATION ON THIS ITEM INDICATES SURPLUS MATERIEL WILL BE CONSIDERED IN THE FOLLOWING TYPES / CATEGORIES

II. EVALUATION CRITERIA (For types/categories deemed acceptable)

ACCEPT-

ABLE (Y/N)

P/N AND

MFG

VERIFI-

CATION

PRIOR

GOV'T

OWNER-

SHIP

100% END

ITEM

INSPECT

TEST AND

VERIFI-

CATION

VERIFI-

ABLE

DIMEN-

SIONS

LOCATION

INSPEC-

TION

TESTING

INITIAL

ACCEPT-

ABILITY

ITEMS

OVERHAUL

AND

CERTIFI-

CATION

OTHER

(Explain in Remarks)

Y X X X

Y X X X

Y X X X

Y X X X

N

N

N

N

G O V T

S U R P L U S

NEW/UNUSED

NEW/RECONDITIONED

NEW/MODIFIED

USED/OVERHAULED

C O M M L

S U R P L U S

NEW/UNUSED

NEW/RECONDITIONED

NEW/MODIFIED

USED/OVERHAULED

SURPLUS EVALUATION CRITERIA (If Section 11a. indicates surplus materiel may be considered). (Fill in blanks as appropriate)

PART NUMBER VERIFICATION 98889(AFMCFARS 5352.211-9011) MFG 817T100-1P/N

PRIOR GOVERNMENT OWNERSHIP (AFMCFARS 5352.211-9015)

100% END ITEM INSPECTION (AFMCFARS 5352.211-9017)

TEST AND VERIFICATION (AFMCFARS 5352.211-9013) TECH ORDER NUMBER

VERIFIABLE DIMENSION (AFMCFARS 5352.211-9012) DESIGN ACTIVITY

DRAWING NUMBER

LOCATION OF INSPECTION TESTING (AFMCFARS 5352.211-9015)

INITIAL ACCEPTABILITY ITEMS (AFMCFARS 5352.211-9014) A QUANTITY OF ITEMS WILL BE TESTED FOR INITIAL ACCEPTANCE

TEST WILL BE CONDUCTED USING THE FOLLOWING CRITERIA (and location of testing)

OVERHAUL AND CERTIFICATION (AFMCFARS 5352.211-9010)

OTHER SPECIAL REQUIREMENTS (Explain)

Caras, Dwight CNAME: 20 APR 2026DATE:

All items will be marked "K" condition (suspended) prior to shipment. Justification for accepting surplus is the urgent need for carcasses to be overhauled due to high MICAPs and carcass constraint.

REMARKS

JUSTIFICATION FOR UNACCEPTABLE SURPLUS MATERIEL

EVALUATOR

Caras, Dwight C

OFFICE SYMBOL

423 SCMS / GUEAB

PHONE

405-582-4121 / 852-4121

COMPLETE DATE

20 APR 2026

SIGNATURE

//SIGNED// Caras, Dwight C

USER TYPE

Engineer

SIGNATURE DATE

20 APR 2026

Page 1 of 1AFMC FORM 813, 20000323 (IMT-V1) Version 1Generated by PRPS using Jasper Reports on 25 Jun 2026