SUPPLYSPEC - 2 Servers for Database.docx

DOCX document 24 KB Posted

Attached to
PD-60-0099; AVDB Dell Server Tech Refresh
Solicitation number
N64498-26-SIMACQ-PD-60-0099
Issued by

About this file

This is a specification document for server procurement supporting a Dell PowerEdge technology refresh initiative. The document details requirements for two Dell PowerEdge servers intended for database operations, specifying technical configurations, performance parameters, and compatibility standards necessary for the Naval Surface Warfare Center, Philadelphia Division (NSWCPD) infrastructure modernization project.

The specification document serves as technical reference material for the Sources Sought notice (Solicitation Number N64498-26-SIMACQ-PD-60-0099), which is being issued for market research purposes by NSWCPD to gather capability information from potential vendors regarding procurement of three Dell PowerEdge servers and Schneider Electric Power Distribution Units. Interested vendors must submit unclassified capability statements via email to jenny.e.tomeo.civ@us.navy.mil by 6:00 PM EST on September 21, 2026, with the solicitation number referenced in the subject line. This is a pre-solicitation notice for market research under FAR Part 10 and does not constitute a binding commitment to award a contract. The Government will not provide compensation for response development costs, will retain all submissions as Government property, and will not release proprietary information without written permission.

View the file

Other files

File Type Posted
SUPPLYSPEC - PDU.docx DOCX document
SUPPLYSPEC - 1 Server for Process Management (1).docx DOCX document
Sources Sought_Notice Code 60 Dell Severs_SAPCOM.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Standalone Tech Refresh Server Specifications/Requirements

Item 0001 Quantity: 2

Each server shall have the following specifications:

1. Chassis:

a. Must be a rackmount server chassis

b. Must include enough slots for sufficient hard drive memory

c. Must include sufficient universal slots

d. Must include six high-performance cooling fan modules option

e. Must include a cable management arm

f. Must include Riser Config 1, 6x8 FH Slots (Gen4), 2x16 LP Slots(Gen4)

2. Power:

a. Power supply must meet requirements of all following specifications.

b. Must include minimum dual redundant (1+1) power supplies

c. Power rating per power supply: minimum 1400W

d. Power supplies must be HOT Plug capable

e. Must include two NEMA 5-15P to C13, 125V, 15A, 3m power cables

3. Processor:

a. Minimum two processors Intel Xeon Silver 2.4GHz with Turbo equivalent or higher

b. Base Frequency: 2.4 GHz or faster

c. Cache: 30 MB minimum

d. Cores: Minimum 12-core/24 threads

e. Must include heatsinks for the CPUs

4. Memory:

a. Must include 512 GB of RAM RDIMM Dual Rank memory sticks

b. Memory sticks must all be of the same specification

c. Technology: 5600 MT/s DDR-5 minimum

d. Error Correction: ECC required

e. Must include a storage controller

5. Graphics:

a. Connections: VGA output port

6. Boot Device

a. Minimum two 480 GB drives (or two drives of higher capacity)

b. Form Factor: M.2 NVMe Comment by Mui, William CIV USN NAVAL SURF WAR CENT (USA): I spec this with the m.2 Vme RAID1 drives. During the last requote from Impres this was changed by them (we did not request).

c. Must include BOSS RAID controller

d. RAID Configuration: RAID 1

e. Must include BOSS cables and bracket

f. No pre-installed OS is required

7. Disk Storage

a. Must include PERC H965i RAID controller

b. RAID Levels: 0, 1, 5, 6, 10, 50, and 60; End user configurable

c. RAID Host Bus Type: 16-lane, PCIe Gen4

d. RAID Cache Memory: 8 GB DDR4 (3200 MT/s)

e. RAID Max Drives: 24

f. Must include minimum 57.6 TB of disk storage comprised of individual hard drive of the same specification

g. Hard drive interface type: SAS-3 12Gb/s

h. Rotational Speed: 10Krpm

i. Sector Format: 512e

8. Networking

a. Must include Broadcom 57414 network card

b. Type: 10/25GbE SFP28

c. Minimum dual network ports

9. Ports

a. Must minimally have one USB 2.0 or 3.0 ports

b. Must minimally have 4 USB ports total

c. Must minimally have 2 USB ports on back of server

d. Must include a network interface card with dual ports

10. Security:

a. Trusted Platform Module (TPM) 2.0 must be installed

11. Storage Expansion Interface Card:

a. Must include Dell HBA355e Adapter Full Height/Low Profile card

b. Must be fully compatible with Dell MD1420 Power Vault enclosure and 2.4TB Hard Drives (SAS ISE 12 Gbps 10K rpm 512e) within Dell MD1420

c. Must be compatible with Dell RAID protocols

12. BIOS Configuration

a. Must include BIOS Performance Optimized Configuration for memory

b. Must include Performance BIOS Setting for maximum computational throughput rather than power savings

13. Other:

a. All installed components must be supplied from an Original Component Manufacturer (OCM), Original Equipment Manufacturer (OEM), or through an OCM/OEM authorized distribution chain. Products or materials shall not be acquired from an independent distributor.

b. Shall not include counterfeit parts or suspected counterfeit parts, defined as material for which credible evidence (including but not limited to, visual inspection or testing) provides reasonable doubt that the component is authentic.

14. Support and Warranty:

a. Must include 24/7 Technical Support for 5 years

b. Must include next business day on-site service after problem diagnosis for 5 years.

c. Must include hardware warranty plus on-site service.

d. Must include option to keep component for Enterprise 5 years