This Statement of Work details a Video Installation and Integration project for Triangle Chapel's Sanctuary at Keesler Air Force Base. The project requires installing three LED monitors (minimum 100 inches) at front of house (FOH) and rear of house (ROH) locations, with Wi-Fi capabilities and the ability to display either identical or different video feeds. The contractor must remove three existing powered projection screens and three projectors currently mounted in the room. The sanctuary has a cathedral ceiling with specific dimensions: 154' back to front, 49'6" wide, with ceiling heights ranging from 17'8" at the wall to 37'7" at the midpoint. The video feed will originate from a production booth located in the center of the balcony, and up to 200 feet of new cable may be required to connect the monitors. The government will provide a Mac Mini with an Apple M1 Chip for video and audio transmission.

The document is part of a Sources Sought announcement for a potential Audio/Video/Lighting upgrade project, issued by the Department of the Air Force Air Education and Training Command. Responses to the Sources Sought Notice are due by 10:00 AM CDT on Wednesday, 18 June 2025, and must be emailed to specified Air Force contract personnel. Interested parties are required to provide company details, confirm compliance with project requirements, and indicate whether the items are available on a Federal Supply Schedule contract. This is a market research effort to identify potential sources for the project, and submission does not guarantee future solicitation or contract award.

View the file

Other files

File Type Posted
Statement of Objectives Larcher Chapel.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Work Triangle Chapel Sanctuary

1. Scope:

Triangle Chapel’s Sanctuary requires a professional Video Installation and Integration project to facilitate religious services, training and resiliency events, and unit functions. The room has a cathedral ceiling. The dimensions of the room are as follows:

Back row to Front of House (FOH) screen location: 154’ Width of room: 49’6” Wall from floor to edge of ceiling (beginning of slant) – 17’8” 2nd Floor Balcony Height: 10’10” higher than floor level.

Ceiling at midpoint: 37’7”

2. Collaborative Equipment

The Contractor shall provide all required technology and installation to equip the sanctuary for video and image presentation. This shall be accomplished through the installation of two LED monitors installed at the front of house (FOH), and an additional LED monitor at rear of house (ROH) to show either the same video feed as FOH, or different. The minimum size for these monitors is 100 inches, and they need to be Wi-Fi capable. This will allow for the ROH monitor to function as a confidence screen, or as an additional presentation screen. The video feed shall originate at the production booth, located in the center of the balcony. New cable shall be run from the production booth to the FOH and ROH LED monitors. Depending on the route chosen, the contractor may need up to 200 feet of cable to connect the production booth to the monitors.

The contractor shall remove three powered projection screens currently installed in the room.

The contractor shall remove three projectors currently installed in the room – one off the balcony and two off front side columns.

The government will provide:

Computer: Mac Mini with Apple M1 Chip, with HDMI send, split for video and audio.

#1 is the closest floor outlet, which is located on either side. #2 is the location of the current powered screens to be removed, and an additional source for electrical power.