Statement of Work Breathing Air High Compressor (rev 2 08192024).pdf

PDF 93 KB Posted

Attached to
Breathing Air High Pressure Compressor System
Solicitation number
W912L6-24-R-9712
Issued by

About this file

This document is a Statement of Work for a Breathing Air High Pressure Compressor System procurement by the 63rd Weapons of Mass Destruction - Civil Support Team (WMD-CST) of the Oklahoma Army National Guard (OKARNG).

The Statement of Work defines the requirements for a brand name compressor system manufactured by Baur Compressors, Inc. to maintain standardized equipment for the WMD-CST. The system must meet specific technical requirements including a 6,000 psi maximum working pressure, automatic cascade control, 13-26 scfm charge rate, and various safety and monitoring features. The government intends to award a Lowest Price Technically Acceptable firm-fixed price contract under FAR Part 12 for this brand name commercial item. Proposals are due by 4 September 2024 in response to Solicitation Number W912L6-24-R-9712, which has been set aside for small businesses under NAICS code 333912.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Product Description: Breathing Air High Pressure Compressor System

1.0 SCOPE.

1.0.1 This product description defines requirement for the 63rd Weapons of Mass Destruction

(WMD) – Civil Support Team (CST) procurement of Breathing Air High Pressure Compressor

System.

1.0.2 WMD-CSTs are required to conduct operations using a self-contained breathing apparatus

(SCBA). The SCBAs are filled using a “Breathing Air High Pressure Compressor System”. The system ensures quality air and standards listed in the below.

1.0.3 Brand name product/equipment is manufactured by Baur Compressor, Inc. The product/equipment described at paragraph 3.0 is brand required to maintain standardization of equipment when training with interagency partners and other CST units.

2.0 APPLICABLE DOCUMENTS.

2.0.1 Army Regulation 750-1 (Army Materiel Maintenance Policy)

2.0.2 Federal Office of Safety and Health Administration 29 CFR, 1910.134 “Compressor

Operations for Breathing Air”

2.0.3 TM 3-6665-428-10, September 2014

2.0.4 JPEO-CBD, SFAE-CBD-NBC memorandum (Chemical Biological Radiological Nuclear

Dismounted Reconnaissance Sets, Kits, and Outfits Bauer Air Compressor Air Quality

Sampling), 10 March 2016

2.0.5 CST Common Table of Allowances (CTA) 50-909, Table 63 / 81

3.0 EQUIPMENT AND SPECIFICATION REQUIREMENTS.

3.0.1 Description of equipment:

Manufacturer Description Part Number

Baur Compressors, Inc Unicus 4i/25 BAU-UN 4I/25H-E3

BAU-GT/CO/III

BAU-CYL-9/6K

3.0.2 Specification of equipment:

System will have filling capability to refill SCBA bottles after use. System will have four stage, air cooled, pressure lubrication high pressure compressor with a maximum working pressure of

6000 psi and an automatic cascade control system rated for 7000 psi service. Pertaining to NFPA

1901 2016 edition, system will have a minimum of three containment fill stations that accommodates SCBA cylinders up to 31” overall length. System is required to have an auto cascade system to simplify use of the system, reduce human error, and safely operate. System is

Product Description: Breathing Air High Pressure Compressor System required to accommodate 13 to 26 scfm charge rate with air storage controls. System will have independent fill pressures and speeds. System is required to have a purification system. System will have a filter replacement monitor and/or have a built-in monitor within the touch screen to alarm/alert for filter replacement; monitor will have light indicator or screen indicator to provide a warning to user to ensure quality air is provided for use. System is required to have a human machine interface touch screen. System is required to have safety shutdowns for low oil pressure and high temperatures. System should have an automatic condensation drainage system with a sensor within the reservoir to show full, likewise, the system should indicate when full and shut down the compressor. System should have an emergency push to stop button. System will have security features to deter from unwarranted tampering, system should have pin code or similar item to allow for securing the system.

4.0 PLACE OF DELIVERY.

OK Army National Guard

USPFO Warehouse

3505 Military Circle NE

Oklahoma City, OK 73111

File details come from the government source that posted it. Updated .