Statement of Requirement Hillstone 270 VDC Load Bank.pdf

PDF 195 KB Posted

Attached to
Load Banks Hillstone 270 VDC
Solicitation number
FA4800-25-Q-A026
Issued by

About this file

This is a Statement of Requirements for one Hillstone 270 VDC Load Bank needed by the Aerospace Ground Equipment Flight of the 1st Maintenance Squadron. The load bank will be used for testing power carts and must be portable to support three Fighter Generation Squadrons at various TDY and deployment locations globally.

The required specifications include: 270VDC maximum operating voltage, 254 Amps maximum current rating, 69 kW maximum power rating, Burton connector type 270R-1100-000, 3kW Incoloy resistors with ±5% tolerance, and Zintec coated steel construction with powder coated finish. The unit must have forced air cooling, IP55/IP20 environmental protection ratings, and operate in temperatures from 0-40°C. Physical requirements specify dimensions of 1140mm x 670mm x 1140mm, weight of 179kg, with swivel castors, forklift pockets, and lifting eyes for mobility. Additional features include digital panel meters, six load channel switches, temperature indicators, and auxiliary power capabilities for both 110V and 240V AC operation.

View the file

Other files

File Type Posted
Brand Name_Combo for Product RFQ.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF REQUIREMENTS

For

Hillstone 270 VDC Load Bank

1 MXS/MXMG

6 December 2024

Purpose: This Statement of Requirements outlines the need for the Hillstone 270 VDC Load Bank to support the Aerospace Ground Equipment Flight of the 1st Maintenance Squadron. Theis new load bank is critical for testing our current fleet of power carts. The load bank is also compact and portable, making it easy to transport and use at various Temporary Duty (TDY) and Deployment locations to support three separate Fighter Generation Squadrons (FGS) simultaneously, often operating in different locations across the globe. Additionally, the Hillstone 270 VDC load bank has been specifically designed to meet the unique requirements of our power carts, which are used to support critical mission operations.

Our existing load bank is not portable and does NOT meet mission requirements if needed in another location, as our current one is not portable. It is made for home station and not for use at TDY and deployment locations.

Requirements: To meet the operational needs of the Aerospace Ground Equipment Flight, the following specifications are required for the new Hillstone 270 VDC Load Bank:

Quantity: One Hillstone 270 VDC Load Bank

Max operating voltage: 270VDC

Max current rating: 254 Amps

Max power rating: 69 kW

DC Cable Set Burton connector type: 270R-1100-000

Resistor Type: 3kW Incoloy 270V resistors; Tolerance +/-5%

Construction: Zintec coated 2mm steel

Finish: Powder coated outer panel; RAL7003

Auxiliary mains: Single phase 110V AC, 50/60Hz, Single phase 240V AC, 50/60Hz

Cooling: Forced air cooling, horizontal fan

Environmental Protection: Rating - Electrical chamber IP55, Heat chamber IP20

Movement: Swivel castors, fork lift pockets, lifting eyes

Temperature: Operating: 0 – 40 ℃, 0 - 104 ℉, Storage: 0 – 80 ℃, 0 - 176 ℉

Current Shunt: 6A:1mV; Accuracy: ± 0.5%

Voltage Measurement: Fused direct terminal connection points

Case Size: 1140mm x 670mm x 1140mm High, 45” x 26” x 45”

Case weight: 179kg, 400lb

Lifting Eyes: 4×M12 long shank collared eyebolts

Test sockets: 4mm, 28VDC +ve & -ve, 270VDC +ve & -ve, Current 6A:1mV

Auxiliary sockets: IEC 60309 Blue 240V 50Hz with IP65 protective cap, IEC 60309 Yellow 120V 60Hz with IP65 protective cap

• Digital Panel Ammeter: 0-300A

• Load channel switches: Channel 1 to 6: Amber illuminated IP65 rocker switches

• Mains switch: Green illuminated IP65 rocker switch

• LED indicators: Over Temperature, 28V Circuit enabled

• 28V switch: 2 position rotary switch

• Green Start button: Latching enabling of control circuit

• Red Stop button: De-energises control circuit

• Max operating voltage: 270VDC

• Max current rating: 254 Amps

• Max power rating: 69 kW

• DC Cable Set Burton connector type: 270R-1100-000

• Resistor Type: 3kW Incoloy 270V resistors; Tolerance +/-5%

• Construction: Zintec coated 2mm steel

• Finish: Powder coated outer panel; RAL7003

• Auxiliary mains: Single phase 110V AC, 50/60Hz, Single phase 240V AC, 50/60Hz

• Cooling: Forced air cooling, horizontal fan

• Environmental Protection: Rating - Electrical chamber IP55, Heat chamber IP20

• Movement: Swivel castors, fork lift pockets, lifting eyes

• Temperature: Operating: 0 – 40 ℃, 0 - 104 ℉, Storage: 0 – 80 ℃, 0 - 176 ℉

• Current Shunt: 6A:1mV; Accuracy: ± 0.5%

• Voltage Measurement: Fused direct terminal connection points

• Case Size: 1140mm x 670mm x 1140mm High, 45” x 26” x 45”

• Case weight: 179kg, 400lb

• Lifting Eyes: 4×M12 long shank collared eyebolts

• Test sockets: 4mm, 28VDC +ve & -ve, 270VDC +ve & -ve, Current 6A:1mV

• Auxiliary sockets: IEC 60309 Blue 240V 50Hz with IP65 protective cap, IEC 60309 Yellow 120V 60Hz with IP65 protective cap

• Digital Panel Voltmeter: 0-300VDC

• Digital Panel Ammeter: 0-300A

• Load channel switches: Channel 1 to 6: Amber illuminated IP65 rocker switches

• Mains switch: Green illuminated IP65 rocker switch

• LED indicators: Over Temperature, 28V Circuit enabled

• 28V switch: 2 position rotary switch

• Green Start button: Latching enabling of control circuit

• Red Stop button: De-energises control circuit

Internal Configuration: The ISUs must be designed to support two separate work centers, allowing efficient storage and organization of deployment assets for UTC HFBE1 missions and TDY certification events for Fighter Generation Squadron and training exercises.

Quick Access to Tools & Equipment: The layout must ensure rapid access to tools and equipment without needing to unpack or reconfigure to get any one tool/item. Reducing response times and allowing seamless integration into Agile Combat Employment configurations.

Airworthiness Compliance: Each ISU-90 must meet all airworthiness standards to support worldwide deployment to any location including bare base environments.

Hazardous Materials Storage: The ISU-90s must be able to safely store and transport hazardous materials, including flammable liquids and corrosives.

Efficient Layout for Tools & Parts: The internal layout must organize all tools and supporting equipment efficiently, with room to store unserviceable parts for return transport.

Split Serviceability: The ISU-90 must be designed with a split configuration, where one side supports the Egress section and the other supports Fuel Systems.

Note: Attached are photos showcasing the storage requirements (and lack thereof) and the current unserviceable condition of the existing units for your reference. We need to fabricate and deliver ISU-90 containers to the Accessories Flight, 1st Maintenance Squadron, ZIP code 23665 prior to April 1, 2025.

1502200700A Cross-Out

Digital Panel Voltmeter: 0-300VDC

Digital Panel Ammeter: 0-300A

Load channel switches: Channel 1 to 6: Amber illuminated IP65 rocker switches

Mains switch: Green illuminated IP65 rocker switch

LED indicators: Over Temperature, 28V Circuit enabled

28V switch: 2 position rotary switch

Green Start button: Latching enabling of control circuit

Red Stop button: De-energises control circuit

Blank Page
Blank Page

File details come from the government source that posted it. Updated .