Text version
Date 4/9/2019
RFP NO. SPRWA1-18-R-0033
RFP TITLE
On the 312237 SP6T Switch SCD, the definition of the RF and DC connections are not defined. Which J port is the input? Which DC pins controls which J port switch arm?
J1 is the output connector.
J2 through J7 are input signals.
E2 thru E7 control port switches for J2 through J7 respectively.
Radio Frequency Switches
Question # Questions Government Response