SPRINGPORT HIGH SCHOOL & ELEMENTARY SCHOOL - BP#2 - CONSTRUCTION DOCUMENTS VOL 2.pdf
PDF 24 MB Posted
- Solicitation number
- RFP SPP 260000002583 2
- Issued by
- Kalamazoo County, Michigan
About this file
This construction document set represents the architectural and structural design specifications for the Springport Public Schools High School and Elementary School addition and renovation project located at 300 West Main Street, Springport, Michigan 49284. The project encompasses the addition of 17,191 square feet including a new gymnasium and corridor space, renovation of the existing 153,054 square-foot facility, and demolition of an existing 8,374 square-foot gymnasium. The construction is organized into three phased occupancy periods: Phase 1 occupancy in August 2027, Phase 2 occupancy in August 2027, and Phase 3 occupancy in December 2028, with corresponding demolition phases beginning November 2026 and continuing through Summer 2027. The project is designed in accordance with the 2021 Michigan Building Code and 2012 NFPA 101 Life Safety Code, with Construction Type IIB classification for new work. The facility includes multiple occupancy groups: Group E (Education) for classroom spaces, Group A-2 (Cafeterias) for the cafetorium, and Group A-4 (Indoor Sports with Spectator Seating) for the gymnasium. The design incorporates automatic fire sprinkler systems in new and renovated areas, with specific code compliance requirements for egress, fire ratings, and accessibility standards.
The structural design establishes specific design loads and material specifications including roof dead loads of 20 PSF, floor dead loads of 64 PSF, roof live loads of 20 PSF, and wind speeds of 115 MPH ultimate design (92 MPH nominal). The project requires concrete with minimum 28-day compressive strength of 4,000 PSI for footings and interior slabs, and 4,500 PSI for weather-exposed elements. Structural materials include ASTM A615 Grade 60 reinforcing steel, masonry with 2,000 PSI compressive strength, and structural steel meeting AISC 360-16 standards. The construction documents include comprehensive special inspection and testing requirements for concrete placement, masonry construction, structural steel welding and bolting, and steel deck installation. The project design accommodates seismic forces based on Seismic Design Category B parameters, with mapped acceleration parameters of Ss=0.108 and S1=0.050. Plumbing fixture requirements are based on actual occupant loads of 489 students and staff for the elementary school, with 27 water closets and 18 lavatories provided. Energy performance requirements comply with ASHRAE Standard 90.1-2019 for Climate Zone 5A, specifying minimum insulation values for roof (R-30 for new construction), walls, and fenestration components. The construction documents were issued for permit dated August 28, 2026, prepared by Tower Pinkster architecture and engineering firm with construction management services provided by a firm located at 211 E Water Street, Suite 201, Kalamazoo, Michigan.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Ea to n Ra pi ds
R d
Devereaux Rd
D-Drive N
I-94
I-94
I-94
C-Drive N
M ile
R d
M ile
R d
Comdon Rd
W Main St
M ap le S t M e ch an ic
S t
Ea to n R ap id s
R d
S p ri ng p o rt
R d
Pope Church Rd
/2
M ile
R d
M ile
R d
Elmer Rd
N P ar m a R d
N P ar m a R d
W Michigan Ave
N G ib bs
R d
N G ib bs
R d
Devereaux Rd
B ro w n
R d
B ro w n
R d
AREA OF WORK
E at o n
R ap id s
R d
W Main St
M ec ha ni c S t
2 3
M o nr o e S t
Oyer St
Grand St
P e ar
S t
E Main St Eaton Rapids Rd
Willow St
M ill S t
G re e n
S t
1 - SPRINGPORT FOOTBALL STADIUM
2 - SPRINGPORT MIDDLE SCHOOL
3 - SPRINGPORT HIGH SCHOOL & ELEMENTARY SCHOOL
4 - SPRINGPORT TRANSPORTATION BUILDING
5 - SPRINGPORT AGRICULTURE BUILDING
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
DESIGN TEAM
ARCHITECT/ENGINEER
/2
/2
:1 :0
P
M
SPRINGPORT HIGH SCHOOL &
ELEMENTARY SCHOOL
SPRINGPORT PUBLIC SCHOOLS
SPRINGPORT PUBLIC SCHOOLS
300 WEST MAIN STREET SPRINGPORT, MI 49284
BP#2 - CONSTRUCTION DOCUMENTS
C O
V E
R S
H E
E T
.0
G
S P
R
IN
G P
O R
T H
IG
H
S C
H O
O L
E
L E
M E
N T
A R
Y S
C H
O O
L
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
W E
S T
M A
IN
S
T R
E E
T S
P R
IN
G
P O
R T
M
I
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
A U
G U
S T
D R
A W
N B
Y
X X
X
VILLAGE MAP
CAMPUS MAP
CONSTRUCTION MANAGER
211 E WATER ST. SUITE 201
KALAMAZOO, MI 49007
PHONE: 269.910.1347
REFERENCED CODES
BUILDING:
ENERGY:
PLUMBING:
MECHANICAL:
FUEL GAS:
ELECTRICAL:
BARRIER-FREE:
USE GROUP:
CONSTRUCTION TYPE:
AUTOMATIC SPRINKLERS:
2021 MICHIGAN BUILDING CODE AND 2012 NFPA 101 LIFE SAFETY CODE
2021 MICHIGAN ENERGY CODE
2021 MICHIGAN PLUMBING CODE
2021 MICHIGAN MECHANICAL CODE
(IFGC) 2021 INTERNATIONAL FUEL GAS CODE
2023 NATIONAL ELECTRICAL CODE WITH MICHIGAN AMENDMENTS
2021 MICHIGAN BUILDING CODE AND 2017 ICC & C A117.1
E, A2, A4
IIB, IIIB
EXISTING ELEMENTARY - NON-SPRINKLED
PROJECT AREA
EXISTING BUILDING: 153,054 SF
EXISTING GYM BEING DEMOLISHED: 8,374 SF
242 E KALAMAZOO AVE. SUITE 100
KALAMAZOO, MICHIGAN 49007
PHONE: 269.343.6133
FAX: 269.343.6633
GYM & CORRIDOR ADDITION: 17,191 SF
ISSUED FOR DATE
PROPOSED ADDITION & RENOVATION - SPRINKLED
VOLUME - 2
NOTE:
MOUNT EQUIPMENT AS SHOWN UNLESS SPECIFIED OTHERWISE.
MAX TWO DEVICES IN ONE HIGHER MOUNT
LOCATION AT LATCH SIDE OF DOOR, PROVIDE RFI
IF MORE DEVICES ARE NECESSARY. WHERE THERE
IS ONE DEVICE, CENTER OVER LOWER DEVICE. (TO
BE WITHIN ADA HEIGHT). (IF SWITCH CANNOT BE
LOCATED ON LATCH SIDE, LOCATE ONE DOOR
LEAF AWAY ON HINGE SIDE.)
DOOR
LOW DEVICES
RECEPTACLEVOICE/DATA
MASONRY COURSING
(WHERE APPLICABLE)
LIGHT SWITCH
F.A. AUDIO/VISUAL
ALIGNMENT NOTES
• ALIGN AND LOCATE CLOSE TOGETHER ANY DEVICES INSTALLED WITHIN 6' HORIZONTALLY.
• CENTER ALL DEVICES WHERE INDICATED ON COLUMN WRAP OR BUMP OUT; STACK AND ALIGN VERTICALLY.
• INSTALL DEVICES AT HEIGHTS INDICATED IN SYMBOL LEGEND UNLESS STACKING PER THIS DETAIL.
• WHERE HEIGHT IS SPECIFICALLY NOTED ON FLOOR PLANS, USE THAT MOUNTING HEIGHT
• CENTER ON DOORFRAME OR WHITEBOARDS ANY DEVICES INDICATED ABOVE.
O R L
A N D
IN
G
FR
O M
F
LO
O R
FR
O M
F
LO
O R O
R L
A N D
IN
G
6' - 0" MIN.
4" MAX
CAMERAS, CLOCKS, WALL
OCCUPANCY SENSORS
WHITE BOARD (WHERE APPLICABLE -
VERIFY WITH DETAILS/PLANS PROPER
INSTALL HEIGHT) CENTER ANY SINGLE
DEVICE WITH CENTER OF WHITE BOARD
ANY DEVICES
SHOWN OVER DOOR
TO BE CENTERED.
EQ EQ
EQ EQ
FR
O M
F
LO
O R O
R L
A N D
IN
G
SHORT THROW PROJECTOR
WHERE APPLICABLE
~12"
FA PULL STATION - HINGE SIDE
OF DOOR 1-LEAF AWAY WITHIN
5'-0" OF EXTERIOR OR STAIR
DOORS, WHEN WALL MOUNT
STROBES ARE ON PROJECT,
ALIGN ABOVE.
WHEN DEVICES ARE WITHIN DIMENSION, STACK
HIGH/LOW VERTICALLY AND GROUP DEVICES AT
SAME HEIGHT. UNLESS DEVICES IS PART OF
TECHNOLOGY DETAIL GROUPING OR SERVING A
FURNITURE GROUP.
CASEWORK, COORDINATE DEVICE BOTTOM
TO BE 2" OVER BACKSPLASH OR OVER
COUNTERTOP (IF NO BACKSPLASH). FOR
LARGE FORMAT TILE, ALIGN EDGE OF DEVICE
WITH HORIZONTAL GROUT LINE CLOSEST TO
COUNTERTOP.
COORDINATE OUTLET LOCATIONS WITH
GROUT LINES, EDGE OF DEVICE ON GROUT
LINE IF POSSIBLE. COORDINATE WITH
INTERIOR DESIGN DRAWINGS.
TYPICAL COLUMN
ENCLOSURE, CHASE OR
BUMP-OUT WITH DEVICES
INDICATED IN PLANS.
EQ EQ
EQEQEQEQ
THERMOSTAT,
SENSORS OR AV
CONTROLLER, CARD
READER, ETC.
DEVICES TO BE 4" MAX DISTANCE APART
B1
I 101
A 301
A
A 311
A 00A-1
A 321
ROOM NUMBER
SHEET NUMBER
DETAIL NUMBER
ROOM NAME
100'-0" : 100'-0"
DISTANCE IN THE "X" DIRECTION FROM THE "Y" BASE LINE
DISTANCE IN THE "Y" DIRECTION FROM THE "X" BASE LINE
TYPICAL SYMBOLS AND REFERENCES
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
SECTION NUMBER
SHEET NUMBER
ELEVATION LETTER
SHEET NUMBER
ELEVATION NUMBER
BARRIER-FREE
REVISION IDENTIFIER (ADDENDUM AND BULLETIN)
COLUMN BUBBLE AND LINE
ELEVATION TAG FOR FLOOR PLANS AND
ELEVATION TAG FOR EXTERIOR
ELEVATIONS AND BUILDING SECTIONS
REFLECTED CEILING PLANS
ELEVATION TAG FOR FLOOR PLANS AND
ELEVATION TAG FOR EXTERIOR
ELEVATIONS AND BUILDING SECTIONS
REFLECTED CEILING PLANS
SHEET NUMBER
ELEVATION NUMBER
DOOR NUMBER - CORRESPONDS
TO THE ROOM NUMBER
LETTER DESIGNATES MORE THAN ONE IN ROOM
FINISH FLOOR
ELEVATION 100'-0"
FINISH FLOOR
ELEVATION 100'-0"
100'-0"
100'-0"
NOTE:
ROOM NAMES AND NUMBERS ON PLANS ARE
FOR CONSTRUCTION PURPOSES ONLY.
COORDINATE WITH OWNER REGARDING
PROPOSED NUMBERS FOR ALL SIGNAGE,
SCHEDULE AND PANEL DESIGNATIONS.
DETAIL REFERENCE BUBBLE
DETAIL REFERENCE BUBBLE
BUILDING SECTION REFERENCE BUBBLE
EXTERIOR ELEVATION REFERENCE BUBBLE
INTERIOR ELEVATION REFERENCE BUBBLE
ELEVATION TAG - EXISTING
ELEVATION TAG - NEW
U N
IT
A
U N
IT
B
ROOM NAME
A101A
A 502
ROOM IDENTIFICATION TAG
UNIT MATCHLINES
DETAIL TITLE
TYPICAL NOTATION SYMBOLS
ELEVATION AND SECTION REFERENCE SYMBOLS
WORKING POINT LAYOUT TAG
BORROWED LIGHT AND DOOR IDENTIFICATION
SYMBOLS
DETAIL TITLE
1" = 0'-1"
A 101
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L
L R
IG
H
T S
R E
S E
R V
E D
/2
/2
:5 :0
P
M
T Y
P
IC
A L S
Y M
B O
L S
A N
D R
E F
E R
E N
C E
S
A B
B R
E V
IA
T
IO
N
S
A N
D D
E V
IC
E
A L
IG
N
M E
N T
G U
ID
E
L
IN
E S
.0
G
S P
R
IN
G P
O R
T H
IG
H
S C
H O
O L
E
L E
M E
N T
A R
Y S
C H
O O
L
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
W E
S T
M A
IN
S
T R
E E
T S
P R
IN
G
P O
R T
M
I
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
A U
G U
S T
D R
A W
N B
Y
X X
X
SCALE: NONE
DEVICE ALIGNMENT GUIDELINES
LIST OF ABBREVIATIONS
ACP ACOUSTICAL PANEL CEILING
AFF ABOVE FINISH FLOOR
ALUM ALUMINUM
ANOD ANODIZED
CFMF COLD FORMED METAL FRAMING
CMU CONCRETE MASONRY UNIT
CONC CONCRETE
DCMU DECORATIVE CONCRETE MASONRY UNIT
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FRT FIRE RESISTANT TREATED
FV FIELD VERIFY
GYP BD GYPSUM BOARD
HM HOLLOW METAL
LVL LAMINATED VENEER LUMBER
MCM METAL COMPOSITE MATERIAL WALL PANEL
OC ON CENTER
PT PRESERVATIVE TREATED
PNT PAINT
SS STAINLESS STEEL
SSM SOLID SURFACE MATERIAL
TYP TYPICAL
VIF VERIFY IN FIELD
WD WOOD
GENERAL NOTES - ARCHITECTURAL - NEW CONSTRUCTION
1 THE OWNER RESERVES THE RIGHT TO REMOVE ANY ITEM FROM THE PROJECT PRIOR TO
COMMENCEMENT OF CONTRACTED DEMOLITION WORK.
2 ALL EXISTING CONDITIONS SHOULD BE FIELD VERIFIED BEFORE WORK BEGINS.
3 DIMENSIONS GIVEN ARE ACTUAL AND ARE TO THE FACE OF MASONRY UNITS OR TO THE
FACE OF STUD FRAMING, UNLESS NOTED OTHERWISE.
4 DETAILS SHOWN ILLUSTRATE DESIGN INTENT, NOT ALL POSSIBLE CONDITIONS. FOR
CONDITIONS NOT SHOWN, USE DETAILS CLOSEST TO CONDITION IN QUESTION.
5 EXTEND ALL INTERIOR WALL PARTITIONS FROM FLOOR TO STRUCTURE/DECK ABOVE
UNLESS NOTED OR DETAILED OTHERWISE.
6 WITHIN BUILDING INTERIOR PROVIDE BULLNOSE BLOCK IN CMU WALL ASSEMBLIES AT
ALL EXPOSED OUTSIDE CORNERS, INCLUDING WINDOW AND DOOR JAMBS, UNLESS
NOTES OR DETAILED OTHERWISE. PROVIDE SQUARE CORNERS AT ALL LOCATIONS
FINISHED WITH WALL TILE, REFER TO FINISH PLANS (I100 SHEETS) FOR LOCATIONS.
7 TOOTH-IN MASONRY AT NEW OPENINGS IN EXISTING WALLS.
8 TOOTH-IN NEW MASONRY INFILL INTO EXISTING OPENINGS AT ALL BULLNOSE BLOCK
LOCATIONS.
9 STUD WALLS SPANNING OVER 12'-0" IN HEIGHT SHALL BE A MINIMUM OF 20 GAGE.
10 DOORS ARE TO BE 4" FROM CORNER OF ROOM, UNLESS NOTED OR DIMENSIONED
OTHERWISE.
11 FIRESTOP ALL INTERCONNECTIONS BETWEEN VERTICAL AND HORIZONTAL SPACES AND
CONCEALED WALL SPACES AT CEILING, FLOOR AND ROOF LEVELS.
12 FIRESEAL ALL PENETRATIONS, SUCH AS, PIPES, DUCTS, CONDUITS, ETC. THROUGH FIRE
AND/OR SMOKE RATED ASSEMBLIES.
13 FOR CONTROL JOINT (C.J.) LOCATIONS REFER TO EXTERIOR ELEVATIONS AND/OR FLOOR
PLANS.
14 PAINT ALL ELECTRICAL PANEL COVERS AND ACCESS PANELS TO MATCH ADJACENT
FINISHES. USING OIL-BASED PAINT, NOT LATEX WALL PAINT.
15 PROVIDE WOOD BLOCKING IN WALLS THAT REQUIRE WALL MOUNTED EQUIPMENT OR
ACCESSORIES. COORDINATE WITH EQUIPMENT OR ACCESSORY MANUFACTURER.
16 PROVIDE ALL ASSOCIATED CURBS FOR ROOF TOP EQUIPMENT AND MECHANICAL ROOF
TOP UNITS. LARGE VOIDS BELOW THE AIR HANDLING UNITS SHALL BE FILLED WITH
INSULATION AS SPECIFIED FOR NOISE CONTROL.
17 ALL EXISTING ROOF TOP PENETRATIONS BEING REMOVED REQUIRE ROOF PATCHING TO
MATCH EXISTING ADJACENT.
18 AT AREAS THAT REQUIRE DEMOLITION OF ADJACENT MATERIALS OR FINISHES FOR THE
INSTALLATION OF NEW WORK, THE DISTURBED ITEMS INTENDED TO BE EXISTING TO
REMAIN SHALL BE PATCHED OR RESTORED TO ORIGINAL CONDITION.
GENERAL NOTES - ARCHITECTURAL - DEMOLITION
1 CONTRACTORS ARE REQUIRED TO INSPECT/REVIEW THE EXISTING BUILDING PRIOR TO
RELATED DEMOLITION WORK. UNLESS NOTED OTHERWISE, REMOVAL OF ANY WALL,
FLOOR OR CEILING INCLUDES ALL GENERAL MECHANICAL AND ELECTRICAL ITEMS WHICH
ARE A PART OF, OR ATTACHED TO IT.
2 CONTRACTOR SHALL VERIFY ALL EXISTING JOB SITE CONDITIONS AND DIMENSIONS AND
BE RESPONSIBLE FOR THE SAME ADVISE CONSTRUCTION MANAGER OF ANY AND ALL
DISCREPANCIES.
3 PATCH FLOORS, WALLS AND CEILINGS DAMAGED DURING CONSTRUCTION AND
DEMOLITION AS REQUIRED. FINISH TO MATCH EXISTING.
4 ACCOMMODATE NEW CONSTRUCTION IF NOT INDICATED.
5 PROTECT ALL EXISTING FINISHES THROUGHOUT PROJECT.
6 REFER TO DEMOLITION ELEVATIONS, SECTIONS AND DETAILS FOR ADDITIONAL
INFORMATION.
7 REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL PLANS FOR
ADDITIONAL DEMOLITION NOTES.
8 SALVAGE ALL UNISTRUT AND PROTECT FOR RE-USE IN NEW CONSTRUCTION, IF
REQUIRED.
9 AT LOCATIONS OF REMOVED WALLS, ALL ASSOCIATED ITEMS ATTACHED TO THE WALL
ARE TO BE REMOVED. SUCH AS: DOORS, WINDOWS, FRAMES, MARKERBOARDS,
TACKBOARDS, TACK STRIPS, ETC.
ISSUED FOR DATE
.0
IG
K
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
/2
/2
:0
:4
P
M
C O
D E
R E
V
IE
W
.0
G
S P
R
IN
G P
O R
T H
IG
H
S C
H O
O L
E L E
M E
N T
A R
Y S
C H
O O
L
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
W E
S T
M A
IN
S
T R
E E
T
S P
R
IN
G P
O R
T
M I
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
A U
G U
S T
D R
A W
N B
Y
X X
X
2021 MICHIGAN REHABILITATION CODE SUMMARY
ALTERATION - ANY CONSTRUCTION OR RENOVATION TO AN EXISTING STRUCTURE OTHER THAN REPAIR OR ADDITION. ALTERATIONS ARE CLASSIFIED AS LEVEL 1, LEVEL 2 AND LEVEL 3
WORK AREA - THAT PORTION OR PORTIONS OF A BUILDING CONSISTING OF ALL RECONFIGURED SPACES AS INDICATED ON THE CONSTRUCTION DOCUMENTS. WORK AREA EXCLUDES OTHER PORTIONS OF THE BUILDING
WHERE INCIDENTAL WORK ENTAILED BY THE INTENDED WORK MUST BE PERFORMED AND PORTIONS OF THE BUILDING WHERE WORK NOT INITIALLY INTENDED BY THE OWNER IS SPECIFICALLY REQUIRED BY THIS
CODE.
ALTERATION - LEVEL 1 (MRC 602.1)
SCOPE - LEVEL 1 ALTERATIONS INCLUDE THE REMOVAL AND REPLACEMENT OR THE COVERING OF EXISTING MATERIALS, ELEMENTS, EQUIPMENT, OR FIXTURES USING NEW MATERIALS, ELEMENTS, EQUIPMENT, OR
FIXTURES THAT SERVE THE SAME PURPOSE.
ALTERATION - LEVEL 2 (MRC 603.1)
SCOPE - LEVEL 2 ALTERATIONS INCLUDE THE RECONFIGURATION OF SPACE, THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE
INSTALLATION OF ANY ADDITIONAL EQUIPMENT.
ALTERATION - LEVEL 3 (MRC 604.1)
SCOPE - LEVEL 3 ALTERATIONS APPLY WHERE THE WORK AREA EXCEEDS 50 PERCENT OF THE BUILDING AREA
CHANGE OF OCCUPANCY (MRC 605.1)
SCOPE - ANY ACTIVITY CLASSIFIED AS A CHANGE OF OCCUPANCY AS DEFINED IN CHAPTER 2. SHALL COMPLY WITH CHAPTER 10
MATERIALS AND METHODS (MRC 702.7)
ALL NEW WORK SHALL COMPLY WITH THE MATERIALS AND METHODS REQUIREMENTS IN THE INTERNATIONAL BUILDING CODE, INTERNATIONAL ENERGY CODE, INTERNATIONAL MECHANICAL CODE AND INTERNATIONAL PLUMBING CODE, AS APPLICABLE, THAT SPECIFY
STANDARDS, DETAIL OF INSTALLATION AND CONNECTION, JOINTS, PENETRATIONS, AND CONTINUITY OF ANY ELEMENT, COMPONENT OR
SYSTEM IN THE BUILDING.
ENERGY CONSERVATION, MINIMUM REQUIREMENTS (MRC 708.1)
LEVEL 1 ALTERATIONS TO EXISTING BUILDINGS OR STRUCTURES DO NOT REQUIRE THE ENTIRE BUILDING OR STRUCTURE TO COMPLY WITH THE ENERGY REQUIREMENTS OF THE INTERNATIONAL ENERGY
CONSERVATION. THE ALTERATIONS SHALL CONFORM TO THE ENERGY REQUIREMENTS AS THEY RELATE TO NEW CONSTRUCTION ONLY.
2021 MBC CODE SUMMARY / 2012 NFPA 101 CODE SUMMARY
EXISTING BUILDING - 153,054 SF
EXISTING GYM BEING DEMOLISHED - 8,375 SF
BUILDING GYM AND CORRIDOR ADDITION - 17,191SF
ADDITIONS ARE SEPARATED FROM THE EXISTING BUILDING WITH A FIRE WALL
OCCUPANCY
E (MBC 305) EDUCATION
A-2 (MBC 303.3) CAFETERIAS
A-4 (MBC 303.5) INDOOR SPORTS WITH SPECTATOR SEATING
ALLOWABLE HEIGHT (FEET) (MBC 504.3)
A & E = 75’ MAX SPRINKLERED (55' MAX NOT SPRINKLERED)
ALLOWABLE HEIGHT (STORIES) (MBC 504.4)
E = 3 STORIES SPRINKLERED (2 STORIES NOT SPRINKLERED)
A-2 = 3 STORIES SPRINKLERED (2 STORIES NOT SPRINKLERED)
A-4 = 3 STORIES SPRINKLERED (2 STORIES NOT SPRINKLERED)
ALLOWABLE AREA (MBC 506.2)
E = 58,000 SF - SINGLE STORY SPRINKLED, IIB CONSTRUCTION
E = 14,500 SF - SINGLE STORY NOT SPRINKLED, IIIB CONSTRUCTION
A-2 = 38,000 SF - SINGLE STORY, SPRINKLERED, IIB CONSTRUCTION
A-4 = 38,000 SF - SINGLE STORY, SPRINKLERED, IIB CONSTRUCTION
REQUIRED SEPARATION OF OCCUPANCIES (HOURS) (MBC 508.4)
E/A = NO SEPARATION REQUIREMENT
CONSTRUCTION TYPE (MBC CH 6)
IIB (MBC CH6)
FIRE-RESISTANCE RATING FOR BUILDING ELEMENTS (MBC TABLE 601)
TYPE IIB CONSTRUCTION
PRIMARY STRUCTURE 0 HOUR
BEARING WALLS
INTERIOR 0 HOUR
EXTERIOR 0 HOUR
NONBEARING WALLS AND PARTITIONS (MBC TABLE 602)
EXTERIOR 0 HOUR (10’-30’)
FLOOR CONSTRUCTION 0 HOUR
ROOF CONSTRUCTION 0 HOUR
FIRE RESISTANT RATING REQUIREMENTS FOR EXTERIOR WALLS (TABLE 705.5)
IIB - OCCUPANCIES A & E - O HOURS
FIRE WALL FIRE RESISTANCE RATINGS (MBC TABLE 706.4)
OCCUPANCIES A & E NEED 2 HOUR FIRE WALLS
HORIZONTAL CONTINUITY (MBC TABLE 706.5)
FIRE WALLS SHALL BE CONTINUOUS AND EXTEND PAST EXTERIOR WALL NOT LESS THAN 18 INCHES
EXCEPTION 2 - AT NON COMBUSTIBLE EXTERIOR WALL, THE RATING CAN EXTEND 4 FEET HORIZONTALLY ON BOTH SIDES OF THE FIRE WALL
VERTICAL CONTINUITY (MBC TABLE 706.6)
FIRE WALLS SHALL EXTEND FROM THE FOUNDATION TO A TERMINATION POINT NOT LESS THAN 30 INCHES ABOVE THE
ADJACENT ROOFS
EXCEPTIONS:
WALLS SHALL BE PERMITTED TO TERMINATE AT THE UNDERSIDE OF NONCOMBUSTIBLE ROOF SHEATHING, DECK OR SLABS WHERE
BOTH BUILDINGS ARE PROVIDED WITH NOT LESS THAN A CLASS B ROOF COVERING. OPENINGS IN THE ROOF SHALL NOT BE LOCATED
WITHIN 4 FEET OF THE FIRE WALL.
FIRE PARTITIONS (MBC 708.1)
CORRIDOR WALLS PER SECTION 1020.3
INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY (MBC TABLE 803.13)
OCCUPANCY GROUPS E - SPRINKLERED
CLASS B - INTERIOR STAIRWAYS AND RAMPS AND EXIT PASSAGEWAYS
CLASS B - CORRIDORS AND ENCLOSURE FOR EXIT ACCESS STAIRWAYS AND RAMPS
CLASS C - ROOMS AND ENCLOSED SPACES
OCCUPANCY GROUPS A - SPRINKLERED
CLASS B - INTERIOR STAIRWAYS AND RAMPS AND EXIT PASSAGEWAYS
CLASS B - CORRIDORS AND ENCLOSURE FOR EXIT ACCESS STAIRWAYS AND RAMPS
CLASS C - ROOMS AND ENCLOSED SPACES
FIRE ALARM AND DETECTION SYSTEMS (MBC 907.2.3 GROUP E)
A MANUAL ALARM SYSTEM THAT INITIATES THE OCCUPANT NOTIFICATION SIGNAL UTILIZING AN EMERGENCY VOICE/ ALARM
COMMUNICATION SYSTEM MEETING THE REQUIREMENTS OF SECTION 907.5.2.2 AND INSTALLED IN ACCORDANCE WITH SECTION
907.6 SHALL BE INSTALLED IN GROUP E OCCUPANCIES. WHERE AUTOMATIC SPRINKLER SYSTEMS OR SMOKE DETECTORS ARE
INSTALLED, SUCH SYSTEMS OR DETECTORS SHALL BE CONNECTED TO THE BUILDING FIRE ALARM SYSTEM.
MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT (MBC 1004.5)
EDUCATION CLASSROOM - 1/20 SF NET
EDUCATION VOCATIONAL - 1/50 SF NET
EDUCATION LOCKER ROOM - 1/15 GROSS
ASSEMBLY - 1/5 SF NET STANDING SPACE
ASSEMBLY - 1/15 SF NET UNCONCENTRATED TABLES AND CHAIRS
BUSINESS AREAS - 150 GROSS
STORAGE - 1/300 GROSS
NUMBER OF EXITS OR ACCESS TO EXITS (MBC TABLE 1006.3.3)
OCCUPANT LOAD PER STORY = 1-500 OCCUPANTS = 2 EXITS MINIMUM PER STORY OR ACCESS TO EXITS PER STORY
PANIC AND FIRE HARDWARE (MBC 1010.2.9)
DOORS SERVING ROOMS OR SPACES WITH AN OCCUPANT LOAD OF 50 OR MORE IN GROUP A & E OCCUPANCY SHALL NOT BE PROVIDED WITH A LATCH OR LOCK OTHER THAN PANIC HARDWARE OR FIRE EXIT
HARDWARE.
EXIT ACCESS TRAVEL DISTANCE (TABLE 1017.2)
200’ MAX OCCUPANCY A & E (MBC TABLE 1017.2 UNSPRINKLERED)
250’ MAX OCCUPANCY A & E (MBC TABLE 1017.2 SPRINKLERED)
CORRIDOR FIRE RESISTANCE RATING (MBC TABLE 1020.1)
1 HOUR
0 HOUR RATING WITH SPRINKLERS PER 903.3.1.1 OR 903.2.1.2
CORRIDORS WIDTH AND CAPACITY (MBC TABLE 1020.2)
72” MINIMUM REQUIRED IN GROUP E WITH 100 OR MORE OCCUPANTS
DEAD ENDS (MBC TABLE 1020.5)
WHERE MORE THAN ONE EXIT OR EXIT ACCESS DOORWAY IS REQUIRED, THE EXIT ACCESS SHALL BE ARRANGED SUCH THAT THERE ARE NO DEAD ENDS IN CORRIDORS MORE THAN 20 FEET IN LENGTH.
COMMON PATH OF TRAVEL (MBC 1030.8)
OCCUPANCY A & E: 30 FEET FROM ANY SEAT TO A POINT WHERE AN OCCUPANT HAS A CHOICE OF TWO PATHS
50 FEET IN SMOKE PROTECTED OPEN AIR ASSEMBLY SEATING
75 FEET COMMON PATH IS ALLOWED WITH LESS THAN 50 OCCUPANTS
SERVICES (MBC 1109.2.1)
IF A SERVICE OR FACILITY IS PROVIDED IN AN AREA THAT IS NOT ACCESSIBLE, THE SAME SERVICE OR FACILITY SHALL BE PROVIDED ON AN ACCESSIBLE LEVEL AND SHALL BE ACCESSIBLE.
WHEELCHAIR SPACES (MBC 1109.2.2)
IN ROOMS AND SPACES USED FOR ASSEMBLY PURPOSES WITH FIXED SEATING, ACCESSIBLE WHEELCHAIR SPACES SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS 1108.2.2.1 AND 1108.2.2.3
2021 MICHIGAN PLUMBING CODE
TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES
ACTUAL OCCUPANT LOAD FOR PLUMBING FIXTURES (MPC 403.1 EXCEPTION. NO.1)
SPRINPGORT ELEMENTARY SCHOOL: PLUMBING FIXTURE COUNT IS BASED ON ACTUAL OCCUPANT LOAD = 489 OCCUPANTS (457 STUDENTS + 32 STAFF)
WATERCLOSETS (MPC 403.1)
SPRINGPORT ELEMENTARY SCHOOL:
1 PER 50 - E OCCUPANCY
489 TOTAL OCCUPANTS / 2 = 245/ 50 = 4.9 = 5
REQUIRED – (10 TOTAL) - 5 WCs FOR BOTH MEN AND WOMEN
PROVIDED – (27 TOTAL) - 6 WCs FOR MEN & 14 WCs FOR WOMEN (20 WCs AND 7 URs)
URINALS (MPC 424.2) SUBSTITUTION FOR WATER CLOSETS.
IN EACH BATHROOM OR TOILET ROOM, URINALS SHALL NOT BE SUBSTITUTED FOR MORE THAN 67 PERCENT OF THE REQUIRED WATER CLOSETS IN ASSEMBLY AND
EDUCATIONAL OCCUPANCIES. URINALS SHALL NOT SUBSTITUTE FOR MORE THAN 50 PERCENT OF THE REQUIRED WATER CLOSETS IN ALL OTHER OCCUPANCIES.
LAVATORIES (MPC 403.1)
SPRINGPORT ELEMENTARY SCHOOL:
1 PER 50 - E OCCUPANCY
489 TOTAL OCCUPANTS / 2 = + 245/ 50 = 4.9 = 5
REQUIRED – (10 TOTAL) – 5 LAVs FOR BOTH MEN AND WOMEN
PROVIDED – (18 TOTAL) – 9 LAVs FOR MEN & 10 LAVs FOR WOMEN
DRINKING FOUNTAIN (MPC 403.1)
WAVERLY ECEC:
1 PER 100 REQUIRED - E OCCUPANCY
489 TOTAL OCCUPANTS / 100 = 4.8 = 5
REQUIRED – (5 TOTAL DFs)
PROVIDED – (7 TOTAL DFs) PLUS (1) BOTTLE FILLER
(MPC 410.4) SUBSTITUTION (FOR DRINKING FOUNTAINS)
IN OCCUPANCIES OTHER THAN RESTAURANTS WHERE DRINKING FOUNTAINS ARE REQUIRED, WATER DISPENSERS SHALL
BE PERMITTED TO BE SUBSTITUTED FOR NOT MORE THAN 50 PERCENT OF THE REQUIRED NUMBER OF DRINKING FOUNTAINS.
OTHER (MPC 403.1)
SPRINGPORT ELEMENTARY SCHOOL:
X SERVICE SINK REQUIRED
X SERVICE SINKS PROVIDED
ENERGY CODE
ASHRAE STANDARD 90.1 - 2019
TABLE 5.5-5 BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 5A
NONRESIDENTIAL
5.1.3 ENVELOPE ALTERNATIONS, EXCEPTION #5
THE ROOF ALTERATIONS NEED NOT COMPLY WITH THESE REQUIREMENTS, PROVIDED SUCH ALTERATIONS WILL NOT INCREASE THE ENERGY USAGE OF THE
BUILDING - #5 ROOF RECOVERING.
ROOFS INSULATION ENTIRELY ABOVE DECK
MAX U-0.032, MIN R-20 c.i. AT EXISTING ROOFS, MIN R-30 c.i. AT NEW ROOFS
WALLS ABOVE GRADE
MASS MAX U-0.090, MIN R-11.4 c.i.
STEEL FRAMED MAX U-0.055, MIN R-13 + R-10 c.i.
WALLS BELOW GRADE
MAX C-0.119, R-7.5 c.i.
FLOORS
MASS MAX U-0.057, MIN R-14.6 c.i.
STEEL JOIST MAX U-0.038, MIN R-30
SLAB ON GRADE FLOORS
HEATED MAX F-0.688, MIN R-15 FOR 24 IN.
OPAQUE DOORS
SWINGING MAX U-0.370
FENESTRATION - 0% TO 40% OF WALL
FIXED - MAX U-0.36, MAX SHGC-0.38
OPERABLE - MAX U-0.45, MAX SHGC-0.33
ENTRANCE DOOR - MAX U-0.63, MAX SHGC-0.33
SKYLIGHTS - 0% TO 3% OF ROOF
ALL TYPES - MAX U-0.50, MAX SHGC-0.40
ISSUED FOR DATE
DN DN
DN
M
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
T T
T T
TTT
T
T
T
M
M
UP
UP
U N
IT A
U N
IT K
U N
IT
A
U N
IT
B
U N
IT K
U N
IT J
U N
IT K
U N
IT J
U N
IT J
U N
IT H
U N
IT
H
U N
IT
G
U N
IT G
U N
IT F
U N
IT A
U N
IT G
U N
IT F
U N
IT E
U N
IT B
U N
IT C
U N
IT A
U N
IT B
U N
IT B
U N
IT C
U N
IT
J
U N
IT
C
U N
IT
F
U N
IT
E
U N
IT
F
U N
IT
D
U N
IT
F
U N
IT
D
PHASE 3
PHASE 3
P H A S E
TEMP WALLS
PHASE 2
OCCUPANCY PHASE 2
AUGUST 2027
OCCUPANCY PHASE 2
AUGUST 2027
OCCUPANCY PHASE 1
AUGUST 2027AUGUST 2027
TEMPORARY
CONSTRUCTION
FENCING
TEMPORARY
CONSTRUCTION
GATE
OCCUPANCY PHASE 3
DECEMBER 2028
OCCUPANCY PHASE 3
DECEMBER 2028
UNIT A UNIT B
UNIT A UNIT C
UNIT A UNIT K
UNIT K UNIT J
UNIT K UNIT J
UNIT J UNIT H UNIT H UNIT F
UNITG UNIT F
UNIT J UNIT H
UNIT F UNIT D
UNIT B UNIT C
UNIT B UNIT C
UNIT J UNIT H
UNIT F UNIT E
UNIT F UNIT D
T E M
P W
A L L
T E M
P W
A L L
T E M
P W
A L L
TEMP WALL
T E M
P W
A L L
TEMPORARY
CONSTRUCTION
FENCING
TEMPORARY
CONSTRUCTION
GATE
DEMO PHASE 1
NOVEMBER 2026
DEMO PHASE 2
SUMMER 2027
DEMO PHASE 2
SUMMER 2027
DEMO PHASE 2
SUMMER 2027
UNIT J UNIT C
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
/2
/2
:0
:3
P
M
P H
A S
IN
G
P L A
N
.0
G
S P
R
IN
G P
O R
T H
IG
H
S C
H O
O L
E L E
M E
N T
A R
Y S
C H
O O
L
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
W E
S T
M A
IN
S
T R
E E
T
S P
R
IN
G P
O R
T
M I
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
A U
G U
S T
D R
A W
N B
Y
X X
X
1" = 50'-0"
OVERALL FIRST FLOOR OCCUPANCY PLAN
1" = 50'-0"
OVERALL FIRST FLOOR DEMOLITION PHASING PLAN
DN
DN
UPUP
T T
T T
TTT
T
T
T
TS
TS
TS
TS
T S
M
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
1. ALL PENETRATIONS THROUGH A FIRE OR SMOKE RATED PARTITION SHOULD BE
SEALED WITH AN APPROVED U.L. RATED PRODUCT.
2. THE TOPS OF ALL FIRE RATED PARTITIONS SHALL BE SEALED TO THE
CONTINUOUS STRUCTURE ABOVE WITH A U.L. RATED SYSTEM OR ASSEMBLY.
3. WOOD BLOCKING IN FIRE-RATED PARTITIONS SHALL BE NON-COMBUSTIBLE
TREATED WOOD.
4. REFER TO SPECIFICATION U.L. RATING INFORMATION.
5. FIRE-RATED WALLS ENDING INTO AN ACOUSTICAL DECK MUST HAVE THE FLUTES
FILLED, REFER TO 'TOP OF WALL DETAIL AT ACOUSTIC DECK' SHOWN ON THIS
SHEET.
• FOR MASONRY WALLS THE MASON SHALL FILL VOIDS AND FIRE SPRAY WITH UL LISTED
MATERIAL.
• FOR STUD WALLS USE FIRE SAFING AND FIRE CAULK.
CODE COMPLIANCE KEY
TRAVEL DISTANCE TO EGRESS DOOR (T.D.)
PERMITTED MAXIMUM TRAVEL DISTANCE PER
CONDITION (P.T.D.)
DIRECTION OF EGRESS
FIRE SAFETY SYMBOLS
FIRE-RATING KEY
XFE
XFEC
FE
FEC
EXISTING FIRE EXTINGUISHER
EXISTING FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
AED
AUTOMATED EXTERNAL DEFIBRILLATOR (AED)
RECESSED CABINET
DESIGNATION RATING PRIORITY
3 HOUR 1
2 HOUR FIRE PARTITION - 708 2
1 HOUR FIRE PARTITION - 708 3
SMOKE RESISTANT 4
COORDINATE ALL REQUIRED DAMPERS WITH MECHANICAL.
T.D. - 100' - 0"
P.T.D. - 200' - 0"
COMMON PATH OF TRAVEL (C.P.T.)
DIRECTION OF EGRESS
C.P.T. - 50' - 0"
MAIN EGRESS EXIT SECONDARY EGRESS EXIT
SMOKE EVACUATION H HORIZONTAL EGRESS
CLASSROOM
A000A
ROOM NAME AND ROOM NUMBER
ROOM AREA
OCCUPANT LOAD FACTOR
OCCUPANT LOAD
1 HOUR FIRE BARRIER - 707 3
2 HOUR FIRE BARRIER - 707 2
2 HOUR FIRE WALL - 706 2
FIRE SAFETY SYMBOLS
REFERENCED CODE
KNOX KNOX BOX
PROJECT AREA
EGRESS
Door #
EGRESS ROOM
UNIT A
UNIT B
U N
IT B
U N
IT C
UNIT B UNIT C
U N
IT
J
U N
IT
C
U N
IT
A
U N
IT
B
U N
IT A
U N
IT K
U N
IT K
U N
IT J
U N
IT K
U N
IT J
U N
IT J
U N
IT G U
N
IT
J
U N
IT
F
U N
IT G
U N
IT F
U N
IT C
U N
IT G
U N
IT
F
U N
IT
E
U N
IT
F
U N
IT
E
UNIT F
UNIT E
U N
IT
F
U N
IT
E
HS MEDIA
CENTER
C352
CLASSROOM
C426
CLASSROOM
C241
CLASSROOM
C347
CLASSROOM
F112CLASSROOM
F111
CLASSROOM
C348
CLASSROOM
C412
CLASSROOM
C236
CLASSROOM
C235
FACULTY
D120
CLASSROOM
C384
CLASSROOM
C383
CLASSROOM
C314
CLASSROOM
C313
CLASSROOM
C379
CLASSROOM
C382
CLASSROOM
C386
WOOD
F119
CLASSROOM
F116
AG SCIENCE
F117
CLASSROOM
F113
CLASSROOM
F127
MECH.
F128
BAND
F108
CHOIR
F101
RECEPTION
D110
HIGH SCHOOL
GYM
H357
KITCHEN
H446
GYMNASIUM
C116
U. MICH
HEALTH
RECEPTION
C115
CLASSROOM
B121
CLASSROOM
B119
CLASSROOM
B118
CLASSROOM
B117
CLASSROOM
B122
CLASSROOM
B123 CLASSROOM
B125
CLASSROOM
B126
CLASSROOM
A415
CLASSROOM
A418
CLASSROOM
A289
CLASSROOM
A412
CLASSROOM
A403
ELEM. MEDIA
CENTER
J100
CLASSROOM
J102
CLASSROOM
J101
CLASSROOM
J109
CLASSROOM
J110
CLASSROOM
J111
CLASSROOM
J112
CLASSROOM
J113
CLASSROOM
K106
CLASSROOM
K105
CLASSROOM
K104
CLASSROOM
K107
CLASSROOM
K108
CLASSROOM
K103
CLASSROOM
K102
CLASSROOM
K101
CLASSROOM
K100
CLASSROOM
K111
CLASSROOM
K110
CLASSROOM
K109
CORRIDOR
C123
SCENE SHOP
G114
FEC
FEC
FEC
FEC
FEC
FEC
FEC
FEC
FEC
T.
D. -
113' - 0"
P.
T.
D. - 250' -
0"
T .D
P .T
.D
T .D
P .T
.D
T.
D. -
121' - 4"
P.
T.
D. -
250' - 0"
T .D
P .T
.D
ELEMENTARY SCHOOL EAST
CLASSROOM WING 2,499 SF TOTAL
UNSPRINKLED 10,145 LEVEL 2
ALTERATION 18% LEVEL 2 ALTERATION
E - NS - IIIB - 14,500 SF ALLOWED
GYMNASIUM 9,402 SF TOTAL SPRINKLED
A4 - S1 - IIB - 38,000 SF ALLOWED
CAFETORIUM 6,866 SF TOTAL SPRINKLED
A2 - S1 - IIB - 38,000 SF ALLOWED
XFEC
XFEC
XFEC
XFEC
XFEC
XFEC
XFEC
XFE
XFE
XFE
2-HOUR FIRE WALL
-H
O U R F
IR
E B
A R R
IE
R
-H
O U R F
IR
E W
A
LL
2-HOUR FIRE WALL
-H
O U R F
IR
E W
A
LL
2-HOUR FIRE WALL
-H
O U R F
IR
E B
A R R
IE
R
2-HOUR FIRE WALL
-H
O U R F
IR
E W
A
LL
C.P.T. - 64' - 6"
C.P.T. - 79' - 10"
C .P
.T
EGRESS
EGRESS
EGRESS
EGRESS
EGRESS
EGRESS
EGRESS
EGRESS
EGRESS340
E G
R E
S S
E G
R E
S S
E G
R E
S S
E G
R E
S S
E G
R E
S S
E G
R E
S S
E G
R E
S S
E G
R E
S S
E G
R E
S S
E G
R E
S S
COURTYARD
C200
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
/2
/2
:0
:3
P
M
O V
E R
A L
L C
O D
E C
O M
P L
IA
N C
E P
L A
N
.0
G
S P
R
IN
G P
O R
T H
IG
H
S C
H O
O L
E L E
M E
N T
A R
Y S
C H
O O
L
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
W E
S T
M A
IN
S
T R
E E
T
S P
R
IN
G P
O R
T
M I
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
A U
G U
S T
D R
A W
N B
Y
X X
X
THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN
COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,
IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN
AN ACCURATE DRAWING
BUILDING: 2021 MICHIGAN BUILDING CODE & 2012 NFPA 101 LIFE SAFETY
CODE
REHABILITATION 2021 MICHIGAN REHAB CODE 2021
ENERGY: 2021 MICHIGAN ENERGY CODE
PLUMBING: 2021 MICHIGAN PLUMBING CODE
MECHANICAL: 2021 MICHIGAN MECHANICAL CODE
FUEL GAS: (IFGC) 2015 INTERNATIONAL FUEL GAS CODE
ELECTRICAL: 2023 MICHIGAN ELECTRICAL CODE, PART 8
BARRIER FREE: 2021 MICHIGAN BUILDING CODE & 2017 ICC & C A117.1
USE GROUP: E (EDUCATION)
CONSTRUCTION TYPE: II B
SPRINKLERS: YES
ADDITION SF 16200 SF
1" = 30'-0"
OVERALL CODE COMPLIANCE PLAN
SPRINGPORT ELEMENTARY / HIGH SCHOOL
A B C D
KEY PLAN
SCALE: NO SCALE
EFG
H
J
F
U N
IT B
U N
IT C
CLASSROOM
B126
CLASSROOM
B121
CORRIDOR
B470
CLASSROOM
B119
CLASSROOM
B118
CLASSROOM
B117
CLASSROOM
B122
CLASSROOM
B123
CLASSROOM
B125
UNIT A
UNIT B
U
N
IT
A
U N
IT
B
U N
IT B
U N
IT C
FEC
-H
O U R F
IR
E W
A
LL
T .D
P .T
.D
T .D
P .T
.D
T .D
P .T
.D
EGRESS
EGRESS
EGRESS
COURTYARD
C200
ELEMENTARY SCHOOL EAST CLASSROOM
WING 2,499 SF TOTAL UNSPRINKLED
10,145 LEVEL 2 ALTERATION 18% LEVEL
2 ALTERATION
E - NS - IIIB - 14,500 SF ALLOWED
1. ALL PENETRATIONS THROUGH A FIRE OR SMOKE RATED PARTITION SHOULD BE
SEALED WITH AN APPROVED U.L. RATED PRODUCT.
2. THE TOPS OF ALL FIRE RATED PARTITIONS SHALL BE SEALED TO THE
CONTINUOUS STRUCTURE ABOVE WITH A U.L. RATED SYSTEM OR ASSEMBLY.
3. WOOD BLOCKING IN FIRE-RATED PARTITIONS SHALL BE NON-COMBUSTIBLE
TREATED WOOD.
4. REFER TO SPECIFICATION U.L. RATING INFORMATION.
5. FIRE-RATED WALLS ENDING INTO AN ACOUSTICAL DECK MUST HAVE THE FLUTES
FILLED, REFER TO 'TOP OF WALL DETAIL AT ACOUSTIC DECK' SHOWN ON THIS
SHEET.
• FOR MASONRY WALLS THE MASON SHALL FILL VOIDS AND FIRE SPRAY WITH UL LISTED
MATERIAL.
• FOR STUD WALLS USE FIRE SAFING AND FIRE CAULK.
CODE COMPLIANCE KEY
TRAVEL DISTANCE TO EGRESS DOOR (T.D.)
PERMITTED MAXIMUM TRAVEL DISTANCE PER
CONDITION (P.T.D.)
DIRECTION OF EGRESS
FIRE SAFETY SYMBOLS
FIRE-RATING KEY
XFE
XFEC
FE
FEC
EXISTING FIRE EXTINGUISHER
EXISTING FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
AED
AUTOMATED EXTERNAL DEFIBRILLATOR (AED)
RECESSED CABINET
DESIGNATION RATING PRIORITY
3 HOUR 1
2 HOUR FIRE PARTITION - 708 2
1 HOUR FIRE PARTITION - 708 3
SMOKE RESISTANT 4
COORDINATE ALL REQUIRED DAMPERS WITH MECHANICAL.
T.D. - 100' - 0"
P.T.D. - 200' - 0"
COMMON PATH OF TRAVEL (C.P.T.)
DIRECTION OF EGRESS
C.P.T. - 50' - 0"
MAIN EGRESS EXIT SECONDARY EGRESS EXIT
SMOKE EVACUATION H HORIZONTAL EGRESS
CLASSROOM
A000A
ROOM NAME AND ROOM NUMBER
ROOM AREA
OCCUPANT LOAD FACTOR
OCCUPANT LOAD
1 HOUR FIRE BARRIER - 707 3
2 HOUR FIRE BARRIER - 707 2
2 HOUR FIRE WALL - 706 2
FIRE SAFETY SYMBOLS
REFERENCED CODE
KNOX KNOX BOX
PROJECT AREA
EGRESS
Door #
EGRESS ROOM
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
/2
/2
:0
:3
P
M
F
IR
S T
F L
O O
R C
O D
E C
O M
P L
IA
N
C E
P L A
N
U N
IT
B
.0
G
B
S P
R
IN
G P
O R
T H
IG
H
S C
H O
O L
E L E
M E
N T
A R
Y S
C H
O O
L
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
W E
S T
M A
IN
S
T R
E E
T
S P
R
IN
G P
O R
T
M I
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
A U
G U
S T
D R
A W
N B
Y
X X
X
1/8" = 1'-0"
FIRST FLOOR CODE COMPLIANCE PLAN - UNIT B
SPRINGPORT ELEMENTARY / HIGH SCHOOL
A B C D
KEY PLAN
SCALE: NO SCALE
EFG
H
J
T S
F
F
F
F
F
C .P
.T
U N
IT B
U N
IT C
GYMNASIUM
C116
ELEC.
C117
STORAGE
C118
STORAGE
C119
BOARD ROOM
C106
VESTIBULE
C100
VESTIBULE
C124
CORRIDOR
C123
OFFICE
C122
E.C.
C121
T.R.
C120
MEN'S
G100
CLASSROOM
B126
CLASSROOM
B121
CORRIDOR
B470
STORAGE
C185
CORRIDOR
C126
U N
IT B
U N
IT C
FEC
FEC
FEC
FEC
FEC
2-HOUR FIRE WALL
-H
O U R F
IR
E W
A
LL
2-HOUR FIRE WALL
-H
O U R F
IR
E B
A R R
IE
R
T .D
P .T
.D
T.
D. -
121' - 4"
P.
T.
D. -
250' - 0"
GYMNASIUM 9,402 SF TOTAL SPRINKLED
A4 - S1 - IIB - 38,000 SF ALLOWED
EGRESS
EGRESS
EGRESS
EGRESS
EGRESS
E G
R E
S S
E G
R E
S S
U N
IT
C
U N
IT
G
DRESSING
ROOM
G103
COURTYARD
C200
NONSTRUCTURAL DECORATIVE GLUE LAMINATED
ARCHES W/ INTUMESCENT PAINT FINISH TO MEET
CLASS C, ASTM E84 FINISH. REFER TO INTERIORS
FOR COLOR OF FINISH
1. ALL PENETRATIONS THROUGH A FIRE OR SMOKE RATED PARTITION SHOULD BE
SEALED WITH AN APPROVED U.L. RATED PRODUCT.
2. THE TOPS OF ALL FIRE RATED PARTITIONS SHALL BE SEALED TO THE
CONTINUOUS STRUCTURE ABOVE WITH A U.L. RATED SYSTEM OR ASSEMBLY.
3. WOOD BLOCKING IN FIRE-RATED PARTITIONS SHALL BE NON-COMBUSTIBLE
TREATED WOOD.
4. REFER TO SPECIFICATION U.L. RATING INFORMATION.
5. FIRE-RATED WALLS ENDING INTO AN ACOUSTICAL DECK MUST HAVE THE FLUTES
FILLED, REFER TO 'TOP OF WALL DETAIL AT ACOUSTIC DECK' SHOWN ON THIS
SHEET.
• FOR MASONRY WALLS THE MASON SHALL FILL VOIDS AND FIRE SPRAY WITH UL LISTED
MATERIAL.
• FOR STUD WALLS USE FIRE SAFING AND FIRE CAULK.
CODE COMPLIANCE KEY
TRAVEL DISTANCE TO EGRESS DOOR (T.D.)
PERMITTED MAXIMUM TRAVEL DISTANCE PER
CONDITION (P.T.D.)
DIRECTION OF EGRESS
FIRE SAFETY SYMBOLS
FIRE-RATING KEY
XFE
XFEC
FE
FEC
EXISTING FIRE EXTINGUISHER
EXISTING FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
AED
AUTOMATED EXTERNAL DEFIBRILLATOR (AED)
RECESSED CABINET
DESIGNATION RATING PRIORITY
3 HOUR 1
2 HOUR FIRE PARTITION - 708 2
1 HOUR FIRE PARTITION - 708 3
SMOKE RESISTANT 4
COORDINATE ALL REQUIRED DAMPERS WITH MECHANICAL.
T.D. - 100' - 0"
P.T.D. - 200' - 0"
COMMON PATH OF TRAVEL (C.P.T.)
DIRECTION OF EGRESS
C.P.T. - 50' - 0"
MAIN EGRESS EXIT SECONDARY EGRESS EXIT
SMOKE EVACUATION H HORIZONTAL EGRESS
CLASSROOM
A000A
ROOM NAME AND ROOM NUMBER
ROOM AREA
OCCUPANT LOAD FACTOR
OCCUPANT LOAD
1 HOUR FIRE BARRIER - 707 3
2 HOUR FIRE BARRIER - 707 2
2 HOUR FIRE WALL - 706 2
FIRE SAFETY SYMBOLS
REFERENCED CODE
KNOX KNOX BOX
PROJECT AREA
EGRESS
Door #
EGRESS ROOM
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
/2
/2
:0
:4
P
M
F
IR
S T
F L
O O
R C
O D
E C
O M
P L
IA
N
C E
P L A
N
U N
IT
C
.0
G
C
S P
R
IN
G P
O R
T H
IG
H
S C
H O
O L
E L E
M E
N T
A R
Y S
C H
O O
L
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
W E
S T
M A
IN
S
T R
E E
T
S P
R
IN
G P
O R
T
M I
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
A U
G U
S T
D R
A W
N B
Y
X X
X
1/8" = 1'-0"
FIRST FLOOR CODE COMPLIANCE PLAN - UNIT C
SPRINGPORT ELEMENTARY / HIGH SCHOOL
A B C D
KEY PLAN
SCALE: NO SCALE
EFG
H
J
DN
DN
T S
M
F
F
C.P.T. - 79' - 10"
C.P.T. - 64' - 6"
MEN'S
G100
CORRIDOR
C126
CAFETORIUM
G111
STAGE
G110
GREEN ROOM
G102
CHOIR
F101
COOLER
F129
FREEZER
F130
VENDING
G112
STORAGE
J108
OFFICE
J107
SCENE SHOP
G114
CUSTODIAL
G113
CLASSROOM
J109CLASSROOM
J110
MECH.
J103
OFFICE
J104
BOYS
J105
GIRLS
J106
T.R.
G104
TR
G105
STORAGE
G106
U N
IT G
U N
IT F
U N
IT J
U N
IT H
U N
IT
J
U N
IT
C
SERVING
H444
FEC
FEC
FEC
FEC
FEC
XFEC
XFEC
XFEC
2-HOUR FIRE WALL
-H
O U R F
IR
E B
A R R
IE
R
-H
O U R F
IR
E W
A
LL
2-HOUR FIRE WALL
2-HOUR FIRE WALL
-H
O U R F
IR
E W
A
LL
T.
D. -
113' - 0"
P.
T.
D. - 250' -
0"
E G
R E
S S
E G
R E
S S
E G
R E
S S
WOMEN'S
G101
DRESSING
ROOM
G103
U N
IT
H
U N
IT
F
1. ALL PENETRATIONS THROUGH A FIRE OR SMOKE RATED PARTITION SHOULD BE
SEALED WITH AN APPROVED U.L. RATED PRODUCT.
2. THE TOPS OF ALL FIRE RATED PARTITIONS SHALL BE SEALED TO THE
CONTINUOUS STRUCTURE ABOVE WITH A U.L. RATED SYSTEM OR ASSEMBLY.
3. WOOD BLOCKING IN FIRE-RATED PARTITIONS SHALL BE NON-COMBUSTIBLE
TREATED WOOD.
4. REFER TO SPECIFICATION U.L. RATING INFORMATION.
5. FIRE-RATED WALLS ENDING INTO AN ACOUSTICAL DECK MUST HAVE THE FLUTES
FILLED, REFER TO 'TOP OF WALL DETAIL AT ACOUSTIC DECK' SHOWN ON THIS
SHEET.
• FOR MASONRY WALLS THE MASON SHALL FILL VOIDS AND FIRE SPRAY WITH UL LISTED
MATERIAL.
• FOR STUD WALLS USE FIRE SAFING AND FIRE CAULK.
CODE COMPLIANCE KEY
TRAVEL DISTANCE TO EGRESS DOOR (T.D.)
PERMITTED MAXIMUM TRAVEL DISTANCE PER
CONDITION (P.T.D.)
DIRECTION OF EGRESS
FIRE SAFETY SYMBOLS
FIRE-RATING KEY
XFE
XFEC
FE
FEC
EXISTING FIRE EXTINGUISHER
EXISTING FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
AED
AUTOMATED EXTERNAL DEFIBRILLATOR (AED)
RECESSED CABINET
DESIGNATION RATING PRIORITY
3 HOUR 1
2 HOUR FIRE PARTITION - 708 2
1 HOUR FIRE PARTITION - 708 3
SMOKE RESISTANT 4
COORDINATE ALL REQUIRED DAMPERS WITH MECHANICAL.
T.D. - 100' - 0"
P.T.D. - 200' - 0"
COMMON PATH OF TRAVEL (C.P.T.)
DIRECTION OF EGRESS
C.P.T. - 50' - 0"
MAIN EGRESS EXIT SECONDARY EGRESS EXIT
SMOKE EVACUATION H HORIZONTAL EGRESS
CLASSROOM
A000A
ROOM NAME AND ROOM NUMBER
ROOM AREA
OCCUPANT LOAD FACTOR
OCCUPANT LOAD
1 HOUR FIRE BARRIER - 707 3
2 HOUR FIRE BARRIER - 707 2
2 HOUR FIRE WALL - 706 2
FIRE SAFETY SYMBOLS
REFERENCED CODE
KNOX KNOX BOX
PROJECT AREA
EGRESS
Door #
EGRESS ROOM
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
/2
/2
:0
:4
P
M
F
IR
S T
F L
O O
R C
O D
E C
O M
P L
IA
N
C E
P L A
N
U N
IT
G
.0
G
G
S P
R
IN
G P
O R
T H
IG
H
S C
H O
O L
E L E
M E
N T
A R
Y S
C H
O O
L
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
W E
S T
M A
IN
S
T R
E E
T
S P
R
IN
G P
O R
T
M I
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
A U
G U
S T
D R
A W
N B
Y
X X
X
1/8" = 1'-0"
FIRST FLOOR CODE COMPLIANCE PLAN - UNIT G
SPRINGPORT ELEMENTARY / HIGH SCHOOL
A B C D
KEY PLAN
SCALE: NO SCALE
EFG
H
J K
ISSUED FOR DATE
CAFETORIUM 6,866 SF TOTAL SPRINKLED
A2 - S1 - IIB - 38,000 SF ALLOWED
M
F
F
F
F
U N
IT
H
U N
IT
F
U N
IT J
U N
IT H
HIGH SCHOOL
GYM
H357
MENS TEAM
LOCKER ROOM
H356
WOMENS TEAM
LOCKER ROOM
H324
PASSAGE
H392
STAIR
H279
STAIR
H431
PASSAGE
H281
STORAGE
H355
PE/COACHES
OFFICE
H396
PE/COACHES
OFFICE
H393
STORAGE
C330
KITCHEN
H446
SERVING
H444
LOBBY
H442
LOBBY
H464
VESTIBULE
H462
VESTIBULE
H441
CORRIDOR
H479
XFEC
XFEC
E G
R E
S S
E G
R E
S S
E G
R E
S S
E G
R E
S S
1. ALL PENETRATIONS THROUGH A FIRE OR SMOKE RATED PARTITION SHOULD BE
SEALED WITH AN APPROVED U.L. RATED PRODUCT.
2. THE TOPS OF ALL FIRE RATED PARTITIONS SHALL BE SEALED TO THE
CONTINUOUS STRUCTURE ABOVE WITH A U.L. RATED SYSTEM OR ASSEMBLY.
3. WOOD BLOCKING IN FIRE-RATED PARTITIONS SHALL BE NON-COMBUSTIBLE
TREATED WOOD.
4. REFER TO SPECIFICATION U.L. RATING INFORMATION.
5. FIRE-RATED WALLS ENDING INTO AN ACOUSTICAL DECK MUST HAVE THE FLUTES
FILLED, REFER TO 'TOP OF WALL DETAIL AT ACOUSTIC DECK' SHOWN ON THIS
SHEET.
• FOR MASONRY WALLS THE MASON SHALL FILL VOIDS AND FIRE SPRAY WITH UL LISTED
MATERIAL.
• FOR STUD WALLS USE FIRE SAFING AND FIRE CAULK.
CODE COMPLIANCE KEY
TRAVEL DISTANCE TO EGRESS DOOR (T.D.)
PERMITTED MAXIMUM TRAVEL DISTANCE PER
CONDITION (P.T.D.)
DIRECTION OF EGRESS
FIRE SAFETY SYMBOLS
FIRE-RATING KEY
XFE
XFEC
FE
FEC
EXISTING FIRE EXTINGUISHER
EXISTING FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
AED
AUTOMATED EXTERNAL DEFIBRILLATOR (AED)
RECESSED CABINET
DESIGNATION RATING PRIORITY
3 HOUR 1
2 HOUR FIRE PARTITION - 708 2
1 HOUR FIRE PARTITION - 708 3
SMOKE RESISTANT 4
COORDINATE ALL REQUIRED DAMPERS WITH MECHANICAL.
T.D. - 100' - 0"
P.T.D. - 200' - 0"
COMMON PATH OF TRAVEL (C.P.T.)
DIRECTION OF EGRESS
C.P.T. - 50' - 0"
MAIN EGRESS EXIT SECONDARY EGRESS EXIT
SMOKE EVACUATION H HORIZONTAL EGRESS
CLASSROOM
A000A
ROOM NAME AND ROOM NUMBER
ROOM AREA
OCCUPANT LOAD FACTOR
OCCUPANT LOAD
1 HOUR FIRE BARRIER - 707 3
2 HOUR FIRE BARRIER - 707 2
2 HOUR FIRE WALL - 706 2
FIRE SAFETY SYMBOLS
REFERENCED CODE
KNOX KNOX BOX
PROJECT AREA
EGRESS
Door #
EGRESS ROOM
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
/2
/2
:0
:4
P
M
F
IR
S T
F L
O O
R C
O D
E C
O M
P L
IA
N
C E
P L A
N
U N
IT
H
.0
G
H
S P
R
IN
G P
O R
T H
IG
H
S C
H O
O L
E L E
M E
N T
A R
Y S
C H
O O
L
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
W E
S T
M A
IN
S
T R
E E
T
S P
R
IN
G P
O R
T
M I
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
A U
G U
S T
D R
A W
N B
Y
X X
X
1/8" = 1'-0"
FIRST FLOOR CODE COMPLIANCE PLAN - UNIT H
SPRINGPORT ELEMENTARY / HIGH SCHOOL
A B C D
KEY PLAN
SCALE: NO SCALE
EFG
H
J
90° HOOK LENGTH
H O
O K L
EN
G
TH
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
/2
/2
:0 :3
P
M
S T
R U
C T
U R
A L G
E N
E R
A L N
O T
E S
.0
S G
A U
G U
S T
S P
R
IN
G P
O R
T H
IG
H
S C
H O
O L
E L E
M E
N T
A R
Y S
C H
O O
L
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
W
E S
T M
A
IN
S T
R E
E T
S P
R
IN
G P
O R
T
M I
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
D R
A W
N B
Y
X X
X
STRUCTURAL LOADS
1. BUILDING CODE:
MICHIGAN BUILDING CODE 2021
2. STRUCTURAL DESIGN CODES AND STANDARDS:
DESIGN LOADS ASCE 7-16
STEEL AISC 360-16
CONCRETE ACI 318-19
MASONRY TMS402-16/ACI 530-16
WOOD ANSI/AWC NDS-18
COLD FORMED METAL AISI S100-16 (2020)
3. BUILDING RISK CATEGORY III
4. DESIGN LOADS:
ROOF DEAD:
ROOFING 1.0 PSF
COVER BOARD 2.0 PSF
INSULATION 1.5 PSF
METAL DECK 2.0 PSF
FRAMING 4.0 PSF
MECHANICAL 4.0 PSF
CEILING 2.0 PSF
MISCELLANEOUS 3.5 PSF
TOTAL 20.0 PSF
FLOOR DEAD:
FINISHED FLOOR 1.0 PSF
CONCRETE & STEEL DECK 50.0 PSF
FRAMING 4.0 PSF
MECHANICAL 4.0 PSF
CEILING 2.0 PSF
MISCELLANEOUS 3.0 PSF
TOTAL 64.0 PSF
DESIGN LIVE LOADS:
ROOFS 20 PSF
MECHANICAL ROOMS 125 PSF
LIGHT STORAGE 125 PSF
LOBBIES AND 1ST FLOOR CORRIDORS 100 PSF
STAIRS 100 PSF
LIVE LOADS HAVE NOT BEEN REDUCED IN ACCORDANCE WITH
THE LIVE LOAD REDUCTION PROVISIONS OF THE BUILDING
CODE.
SNOW:
GROUND SNOW Pg = 30.0 PSF
IMPORTANCE FACTOR I = 1.1
THERMAL FACTOR Ct = 1.0
EXPOSURE FACTOR Ce = 1.0
FLAT ROOF SNOW Pf = 23.1 PSF
SLOPE FACTOR Cs = 1.0
SNOW DRIFT LOADS AS INDICATED
WIND:
ULTIMATE DESIGN WIND SPEED Vult = 115 MPH
NOMINAL DESIGN WIND SPEED Vasd = 92 MPH
EXPOSURE CATEGORY B
INTERNAL PRESSURE COEFFICIENT ± 0.18
TOPOGRAPHIC FACTOR Kzt = 1.0
DIRECTIONALITY FACTOR Kd = 0.85
GROUND ELEVATION FACTOR Ke = 1.0
GUST EFFECT FACTOR G = 0.85
SEISMIC:
SEISMIC IMPORTANCE FACTOR Ie = 1.25
MAPPED ACCELERATION PARAMETERS Ss = 0.108 & S1 = 0.050
SITE CLASS D
DESIGN ACCELERATION PARAMETERS Sds = 0.115 & Sd1 = 0.080
SEISMIC DESIGN CATEGORY B
SEISMIC FORCE RESISTING SYSTEM INTERMEDIATE REINFORCED MASONRY SHEAR WALLS
SEISMIC RESPONSE COEFFICIENT Cs = 0.041
RESPONSE MODIFICATION COEFFICIENT R = 3.5
ANALYSIS PROCEDURE USED EQUIVALENT LATERAL FORCE
COMPONENTS & CLADDING ULTIMATE WIND PRESSURES
ZONE 10 SF 50 SF 100 SF
WALL
NEGATIVE ZONE 4 -24.0 PSF -21.7 PSF -20.8 PSF
NEGATIVE ZONE 5 -29.6 PSF -25.0 PSF -23.0 PSF
POSITIVE ZONES 4 & 5 22.2 PSF 19.9 PSF 18.9 PSF
PARAPET
WINDWARD PARAPET ZONE 4 41.3 PSF 35.9 PSF 34.9 PSF
WINDWARD PARAPET ZONE 5 59.0 PSF 52.3 PSF 51.4 PSF
LEEWARD PARAPET ZONE 4 -46.2 PSF -41.6 PSF -39.7 PSF
LEEWARD PARAPET ZONE 5 -51.8 PSF -44.9 PSF -42.0 PSF
ROOF
NEGATIVE ZONE 1 -27.6 PSF -24.2 PSF -24.2 PSF
NEGATIVE ZONE 2 -50.9 PSF -43.3 PSF -40.1 PSF
NEGATIVE ZONE 3 -69.4 PSF -54.2 PSF -47.7 PSF
POSITIVE ALL ZONES 16.0 PSF 16.0 PSF 16.0 PSF
OVERHANG ZONE 1 -34.9 PSF -33.5 PSF -32.9 PSF
OVERHANG ZONE 2 -47.2 PSF -37.1 PSF -32.7 PSF
OVERHANG ZONE 3 -65.7 PSF -48.0 PSF -40.3 PSF
GENERAL
1. ADDITIONAL ENGINEERING EFFORT TO BRING BUILT CONDITIONS TO COMPLIANCE WITH STRUCTURAL DRAWINGS MAY
RESULT IN ADDITIONAL FEE.
2. THESE NOTES SUPPLEMENT THE PROJECT SPECIFICATIONS, SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
3. THESE DRAWINGS REPRESENT THE COMPLETED PROJECT WHICH HAS BEEN DESIGNED FOR THE DEAD LOAD WEIGHT OF
MATERIALS INDICATED PLUS THE SUPERIMPOSED LIVE LOADS INDICATED IN THE DESIGN DATA. IT IS THE CONTRACTOR’S
RESPONSIBILITY TO DETERMINE ALLOWABLE CONSTRUCTION LOADS AND TO PROVIDE PROPER DESIGN AND
CONSTRUCTION OF FALSEWORK, FORMWORK, STAGING, BRACING, AND SHORING. CONTRACTOR HAS SOLE
RESPONSIBILITY FOR CONSTRUCTION MEANS AND METHODS, SEQUENCES, AND PROCEDURES OF CONSTRUCTION. THE
STRUCTURE IS STABLE ONLY IN ITS COMPLETED FORM, WITH COMPLETED CONNECTIONS, AND FIELD INSTALLED
MATERIALS HAVING REACHED SPECIFIED DESIGN STRENGTH.
4. CROSS CHECK ALL DIMENSIONS AND ELEVATIONS INDICATED. REPORT DISCREPANCIES FOR CLARIFICATION PRIOR TO
STARTING CONSTRUCTION OR ORDERING MATERIALS. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS NOT
INDICATED ON THE STRUCTURAL DRAWINGS. DO NOT SCALE THESE DRAWINGS.
5. IN THE CASE OF A CONFLICT WITHIN THE CONTRACT DOCUMENTS, INCLUDING DRAWINGS AND SPECIFICATIONS, THE
MOST STRINGENT REQUIREMENTS WILL GOVERN.
6. REFER TO ARCHITECTURAL, MECHANICAL, PLUMBING, ELECTRICAL, CIVIL, AND FOOD SERVICE DRAWINGS FOR SIZE AND
LOCATION OF OPENINGS, SLEEVES, CONCRETE HOUSEKEEPING PADS, INSERTS, EMBEDDED ITEMS, CURBS, RAMPS, DRAINS, DEPRESSIONS, ETC. NOTIFY STRUCTURAL ENGINEER OF ANY DISCREPANCIES.
7. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR DETAILED INFORMATION REGARDING SPECIAL FINISHES
ON STRUCTURAL MEMBERS, FIREPROOFING, WATERPROOFING, ETC.
8. REFER TO ARCHITECTURAL DRAWINGS FOR MASONRY AND DRYWALL NON-LOADBEARING PARTITIONS. PROVIDE SLIP
CONNECTIONS THAT ALLOW VERTICAL MOVEMENT AT THE HEADS OF SUCH PARTITIONS. CONNECTIONS SHALL SUPPORT
THE TOP OF THE WALLS LATERALLY FOR THE CODE REQUIRED LATERAL LOAD.
9. REPRODUCTION OF THE STRUCTURAL DRAWINGS FOR SUBMISSION AS SHOP DRAWINGS IS PROHIBITED. SUBMITTALS
PRODUCED IN THIS MANNER WILL BE REJECTED.
10. DELEGATED DESIGN SUBMITTALS: PORTIONS OF THE DESIGN HAVE BEEN DELEGATED AND WILL BE DESIGNED BY
PRODUCT MANUFACTURERS QUALIFIED LICENSED ENGINEERS. THE STRUCTURAL ENGINEER OF RECORD WILL ONLY
REVIEW SUBMITTALS OF THESE SYSTEMS FOR GENERAL CONFORMANCE WITH THE PROJECT PARAMETERS INDICATED
AND IS NOT RESPONSIBLE FOR DELEGATED DESIGN SUBMITTAL. DELEGATED DESIGN SUBMITTALS INCLUDE, BUT ARE
NOT LIMITED TO THE FOLLOWING. SEE SPECIFICATIONS FOR ANY ADDITIONAL DELEGATED DESIGNS REQUIRED.
STRUCTURAL STEEL CONNECTIONS
COLD-FORMED METAL FRAMING
PRE-FABRICATED STEEL STAIRS
METAL LADDERS
STOREFRONT WINDOW WALL SYSTEMS
11. CONTRACTOR TO PROVIDE A SUBMITTAL FOR ENGINEER REVIEW FOR THE FOLLOWING. SEE SPECIFICATIONS FOR ANY
ADDITIONAL SUBMITTALS REQUIRED.
CONCRETE MIX
CONCRETE REINFORCEMENT
MASONRY REINFORCEMENT
STRUCTURAL STEEL
STEEL JOISTS
STEEL DECK
STRUCTURAL GENERAL NOTES
ABBREVIATIONS
ARCH ARCHITECTURAL
BRG BEARING
BS BOTTOM OF STEEL ELEVATION
BTM BOTTOM
CIP CAST-IN-PLACE
CJ CONTROL OR CONSTRUCTION JOINT
CL CENTER LINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONT CONTINUOUS
CVR COVER
DBE DECK BEARING ELEVATION
DIA DIAMETER
EA EACH
EF EACH FACE
EL ELEVATION
EQ EQUAL
EW EACH WAY
FDN FOUNDATION
FO FLOOR OPENING
GA GAUGE
HDG HOT-DIP GALVANIZED
HORIZ HORIZONTAL
k KIP = 1,000 POUNDS
MAX MAXIMUM
MIN MINIMUM
NTS NOT TO SCALE
OC ON-CENTER
PL PLATE
PSF POUNDS PER SQUARE FOOT
PT PRESSURE TREATED
RO ROOF OPENING
SIM SIMILAR
SP SOUTHERN PINE
T&B TOP AND BOTTOM
TF TOP OF FOOTING ELEVATION
TP TOP OF PIER ELEVATION
TS TOP OF STEEL ELEVATION
TW TOP OF WALL ELEVATION
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
VIF VERIFY IN FIELD
w/ WITH
WWF WELDED WIRE FABRIC
DEMOLITION
1. PRIOR TO DEMOLITION, PROVIDE APPROPRIATE SHORING FOR BOTH VERTICAL LOADS AND BRACING AGAINST LATERAL
DISPLACEMENT AS REQUIRED TO MAINTAIN STABILITY OF THE STRUCTURE. DESIGN OF TEMPORARY SHORING SYSTEMS
IS PART OF THE CONTRACTORS “MEANS AND METHODS” AND IS THE RESPONSIBILITY OF THE CONTRACTOR.
2. PROTECT ALL ELEMENTS TO REMAIN BOTH INSIDE AND OUTSIDE OF CONSTRUCTION AREA FROM DAMAGE DURING
DEMOLITION AND RECONSRUCTION INCLUDING, BUT NOT LIMITED TO, BUILDING FACADES, ROOFING, WINDOWS, LIGHT
FIXTURES, LOUVERS, ETC.
3. DEMOLITION OPERATIONS MUST COMPLY WITH LOCAL ORDINANCES (INCLUDING BUT NOT LIMITED TO NOISE LEVELS AND
DUST CONTROL) AT ALL TIMES. CONTRACTOR IS REQUIRED TO VERIFY AND COMPLY WITH ALL LOCAL REQUIREMENTS.
4. PROVIDE TEMPORARY PROTECTION OF WORK AREAS AND ADJACENT AREAS PRIOR TO REMOVAL OF WATERPROOF
MEMBRANES AND FLASHINGS.
EXISTING CONDITIONS
1. ALL EXISTING STRUCTURAL ELEMENTS (SLABS, BEAMS, WALLS, COLUMNS, FOUNDATIONS, ETC.) SHALL REMAIN INTACT
UNLESS SPECIFICALLY NOTED TO BE REMOVED BY THE MOST RECENT DEMOLITION DOCUMENTS OR OTHERWISE NOTED
ON THE STRUCTURAL DRAWINGS.
2. DIMENSIONS AND ELEVATIONS RELATED TO EXISTING CONSTRUCTION ARE APPROXIMATE AND FOR REFERENCE ONLY. ALL
INFORMATION ON THESE DRAWINGS RELATED TO EXISTING CONDITIONS IS BASED ON AVAILABLE DESIGN DOCUMENTS
AND LIMITED FIELD OBSERVATION. CONTRACTOR SHALL FIELD VERIFY DIMENSIONS, ELEVATIONS, AND EXISTING
CONDITIONS PRIOR TO CONSTRUCTION. REPORT DISCREPANCIES PRIOR TO STARTING CONSTRUCTION OR ORDERING
MATERIALS.
3. THIS PROJECT REQUIRES A SIGNIFICANT AMOUNT OF DRILLING INTO THE EXISTING REINFORCED CONCRETE STRUCTURE.
THE CONTRACTOR WILL NOT RECEIVE ADDITIONAL PAYMENT FOR DIFFICULTIES ENCOUNTERED IN DRILLING DUE TO
HARDNESS OF MATERIALS, HITTING OF EXISTING REINFORCING, ETC.. ALL COSTS ASSOCIATED WITH REDRILLING OF
HOLES DUE TO HITTING EXISTING REINFORCING STEEL SHALL BE BORNE BY THE CONTRACTOR. THIS INCLUDES FILLING
UNNECESSARY AND UNUSED HOLES WITH EPOXY GROUT. DO NOT CUT REINFORCING STEEL DURING CONCRETE DRILLING
OR CORING OPERATIONS. LOCATE REINFORCING WITH A PACHOMETER OR OTHER NON-DESTRUCTIVE TESTING DEVICE
PRIOR TO DRILLING OR CORING OPERATIONS.
4. CORE DRILLS REQUIRED BY MECHANICAL OR ELECTRICAL TRADES, BUT NOT SHOWN ON THE STRUCTURAL DRAWINGS
SHALL BE DOCUMENTED IN SKETCH FORM SHOWING EXACT DIMENSIONS AND LOCATIONS. THE SKETCH SHALL BE
SUBMITTED TO THE ENGINEER FOR REVIEW PRIOR TO PROCEEDING WITH THE DRILLING OPERATION.
5. WHERE NEW CONCRETE IS BEING PLACED AGAINST EXISTING CONCRETE AND CONNECTED BY DRILLING AND DOWELING, CLEAN EXISTING CONCRETE SURFACE THOROUGHLY TO REMOVE ALL DEBRIS, LAITANCE, AND EXISTING COATINGS OR
MEMBRANCES. DAMPEN FACE OF EXISTING CONCRETE TO A SATURATED SURFACE DRY CONDITION IMMEDIATELY
BEFORE PLACING NEW CONCRETE.
FOUNDATIONS
1. LOCATE ALL UNDERGROUND UTILITIES BEFORE STARTING WORK. CONTACT UTILITY LOCATING SERVICES PRIOR TO
EXCAVATION. IN MICHIGAN CALL "MISS DIG" 800-482-7171 AT LEAST 72 HOURS PRIOR TO STARTING WORK.
2. ANY EXISTING UTILITIES INDICATED ON DRAWINGS ARE BASED ON ORIGINAL CONSTRUCTION DRAWINGS AND SITE
SURVEYS. EXACT UTILITY LOCATIONS AND ELEVATIONS OF UTILITIES MUST FIELD VERIFIED BY THE CONTRACTOR PRIOR
TO BEGINNING WORK.
3. FOUNDATION DESIGN IS BASED ON THE SOILS INVESTIGATION REPORT NUMBER 251635 BY MATERIALS TESTING
CONSULTANTS DATED OCTOBER 2025.
4. FOUNDATIONS SHALL BEAR ON SOILS HAVING A MINIMUM ALLOWABLE BEARING PRESSURE OF 2,500 PSF FOR SPREAD
FOOTINGS AND 2,500 PSF FOR WALL FOOTINGS.
5. FOOTINGS SHALL BEAR ON UNDISTURBED SOIL AT ELEVATIONS SHOWN ON THE DRAWINGS. IF OVER-EXCAVATION IS
REQUIRED, ENGINEERED COMPACTED FILL SHALL BE PLACED PER SPECIFICATIONS UP TO BEARING ELEVATION. ALL
ENGINEERED COMPACTED FILL SHALL BE PLACED IN THE PRESENCE OF AND AS DIRECTED BY A QUALIFIED GEOTECHNICAL
ENGINEERING FIRM. LOCATION AND EXTENT OF AREAS TO RECEIVE ENGINEERED COMPACTED FILL SHALL BE PER THE
GEOTECHNICAL REPORT AND TESTING OF SOILS SHALL BE ACCORDING TO SPECIFICATIONS PRIOR TO PLACEMENT OF
FOOTINGS.
6. CONTRACTOR SHALL PROVIDE SLEEVES FOR ALL OPENINGS REQUIRED IN WALLS. NO CORE DRILLING WILL BE ALLOWED
WITHOUT PRIOR APPROVAL BY THE STRUCTURAL ENGINEER. COORDINATE LOCATION AND SIZE OF OPENINGS WITH
APPLICABLE CONTRACTORS.
7. DO NOT REPAIR MISPLACED OR DAMAGED COLUMN ANCHOR BOLTS WITHOUT PRIOR APPROVAL BY THE STRUCTURAL
ENGINEER.
8. WHERE FOUNDATION WALLS ARE TO HAVE EARTH PLACED ON EACH SIDE, PLACE FILL ON ALTERNATING SIDES OF WALL IN
SHALLOW LIFTS.
9. COORDINATE ELECTRICAL SERVICE GROUNDING REQUIREMENTS TO FOUNDATION REINFORCING WITH ELECTRICIAN. SEE
ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.
LOCATION 28 DAY f'c (PSI) AIR CONTENT MAX W/C
FOOTINGS & FOUNDATION WALLS 4,000 6% ± 1% 0.50
INTERIOR SLABS 4,000 NO TEST 0.50
RETAINING WALLS & ALL OTHER CONCRETE EXPOSED TO WEATHER 4,500 6% ± 1% 0.45
CONCRETE
1. ALL MATERIAL AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH APPLICABLE AMERICAN CONCRETE INSTITUTE (ACI)
DOCUMENTS REFERENCED IN SPECIFICATIONS.
2. MATERIAL PROPERTIES:
3. REINFORCING BARS SHALL BE ASTM A615 GRADE 60 UNO.
4. REFER TO SPECIFICATIONS FOR ALL TESTING REQUIREMENTS. SUBMIT EACH CONCRETE MIX DESIGN FOR REVIEW.
SUBMITTAL SHALL CONSIST OF DESIGN MIXES FOR EACH TYPE AND STRENGTH OF CONCRETE AND INCLUDE DATA BY
EITHER LABORATORY TRIAL MIX OR FIELD TEST DATA BASE PER ACI 318.
5. ALL CONCRETE SHALL BE CURED FOR A MINIMUM OF 7 DAYS PRIOR TO REMOVAL OF FORMS. IF FORMS ARE REMOVED
BEFORE THE END OF CURING PERIOD, COAT SURFACES WITH LIQUID CURING COMPOUND.
6. PROVIDE DOWELS IN WALL FOOTINGS WITH EQUAL SIZE AND SPACING AS VERTICAL WALL STEEL, UNO.
7. ALL OPENINGS IN SLABS AND WALLS SHALL HAVE REINFORCING ON EACH SIDE EQUAL TO HALF THE AMOUNT OF
REINFORCING DISPLACED. REFER TO TYPICAL DETAIL.
8. ALL CONCRETE SLABS ON GRADE SHALL BE REINFORCED WITH 6"x6"- W1.4xW1.4 WELDED WIRE FABRIC UNO.
9. SEE ARCHITECTURAL DRAWINGS FOR SIZE, DEPTH, AND LOCATION OF DEPRESSED FLOOR SLABS REQUIRED.
10. PROVIDE CLASS "B" TENSION LAP SPLICES FOR ALL BARS UNO.
11. TOP BARS ARE DEFINED AS HORIZONTAL REINFORCEMENT POSITIONED SUCH THAT MORE THAN 12" OF FRESH
CONCRETE IS PLACED BELOW THE REINFORCEMENT. ALL HORIZONTAL BARS IN WALLS SHALL BE CONSIDERED TOP BARS.
12. MECHANICAL COUPLERS DEVELOPING AT LEAST 125% OF THE BAR YIELD STRENGTH MAY BE USED AT CONTRACTOR'S
OPTION IN LIEU OF LAP SPLICES. CONTRACTOR SHALL SUBMIT MECHANICAL COUPLER PRODUCT DATA TO ENGINEER FOR
REVIEW PRIOR TO STARTING CONSTRUCTION OR ORDERING MATERIAL.
13. USE NON-SHRINK, NON-METALLIC GROUT UNDER ALL BASE PLATES, BEARING PLATES, AND SETTING PLATES.
14. TOP AND BOTTOM HORIZONTAL REINFORCEMENT IN WALLS TO BE LOCATED NO LESS THAN 2" AND NO MORE THAN 3"
FROM TOP OR BOTTOM OF THE WALL.
15. WHERE BAR LENGTHS ARE GIVEN ON DRAWINGS, THE LENGTH OF ANY HOOK, IF REQUIRED, IS NOT INCLUDED.
16. THE HARDENED CONCRETE OF CONSTRUCTION JOINTS SHALL BE CLEANED TO REMOVE ALL DEBRIS AND LAITANCE.
DAMPEN SURFACE OF HARDENED CONCRETE TO A SATURATED SURFACE DRY CONDITION IMMEDIATELY BEFORE PLACING
FRESH CONCRETE.
17. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A1064 DELIVERED IN FLAT SHEETS.
18. LAP WELDED WIRE FABRIC ONE SPACE (TWO CROSS WIRES) + 2" AT ALL EDGES AND ENDS OF SHEETS.
19. WELDING OF REINFORCING STEEL IS NOT PERMITTED UNO.
20. COMPLY WITH THE ARCHITECTURAL DRAWINGS FOR LOCATION AND EXTENT OF SPECIAL FINISHES OR TREATMENTS TO
EXPOSED CONCRETE.
BAR SIZE
LAP LENGTH (fc = 4,000 PSI) STANDARD 90°
HOOK LENGTH
STANDARD 180°
HOOK LENGTHTOP BARS OTHER BARS
#3 25" 19" 6" 4"
#4 33" 25" 8" 4 1/2"
#5 41" 31" 10" 5"
#6 49" 37" 12" 6"
#7 71" 54" 14" 7"
#8 81" 62" 16" 8"
CONCRETE REINFORCING CLEAR COVER REQUIREMENTS
OCCURANCES COVER
1. CONCRETE CAST AGAINST AND PERMANENTLY IN CONTACT WITH GROUND 3"
2. CONCRETE EXPOSED TO WEATHER OR IN CONTACT WITH GROUND
A. #5 BAR AND SMALLER 1 1/2"
B. #6 BAR AND LARGER 2"
3. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND
A. SLABS, JOISTS, AND WALLS (NOT LARGER THAN #11 BAR) 3/4"
B. BEAMS, COLUMNS, AND PIERS 1 1/2"
NOTE: CLEAR COVER DIMENSIONS LISTED ARE…