SPRINGPORT HIGH SCHOOL & ELEMENTARY SCHOOL - BP#2 - CONSTRUCTION DOCUMENTS VOL 1.pdf
PDF 28 MB Posted
- Solicitation number
- RFP SPP 260000002583 2
- Issued by
- Kalamazoo County, Michigan
About this file
This is a construction document set for the Springport High School & Elementary School Addition and Renovation project in Springport, Michigan, prepared for Springport Public Schools. The project encompasses a significant renovation and addition to the existing 153,054 square-foot school complex, with the demolition of an existing 8,374 square-foot gymnasium and the construction of a new 17,191 square-foot gymnasium and corridor addition. The work is organized into three phases with occupancy scheduled for August 2027 (Phases 1 and 2) and December 2028 (Phase 3), with demolition occurring in November 2026 (Phase 1) and Summer 2027 (Phase 2). The project includes both sprinkled and unsprinkled areas, with the elementary school east classroom wing comprising 2,499 square feet of unsprinkled space, a gymnasium of 9,402 square feet of sprinkled space, and a cafetorium of 6,866 square feet of sprinkled space. The facility will serve approximately 489 occupants in the elementary school with 10 total water closets (27 provided), 10 total lavatories (18 provided), and 5 required drinking fountains (7 provided plus 1 bottle filler).
The project complies with the 2021 Michigan Building Code, 2012 NFPA 101 Life Safety Code, 2021 Michigan Rehabilitation Code, 2021 Michigan Energy Code, 2021 Michigan Plumbing Code, 2021 Michigan Mechanical Code, 2023 National Electrical Code with Michigan Amendments, and 2017 ICC & CA117.1 accessibility standards. The construction type is IIB with allowable areas of 58,000 square feet for single-story sprinkled education occupancy (E), 38,000 square feet for sprinkled assembly occupancy (A-2 and A-4), and 14,500 square feet for unsprinkled education occupancy. Fire walls rated at 2 hours separate occupancies, and the project includes comprehensive fire safety provisions with multiple fire extinguisher cabinets and emergency egress routes. The site encompasses multiple parcels in Jackson County Township of Springport with easements documented for sanitary, utility, and telephone companies, and benchmark elevations have been established using NAVD88 datum for construction coordination.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Ea to n Ra pi ds
R d
Devereaux Rd
D-Drive N
I-94
I-94
I-94
C-Drive N
M ile
R d
M ile
R d
Comdon Rd
W Main St
M ap le S t M e ch an ic
S t
Ea to n R ap id s
R d
S p ri ng p o rt
R d
Pope Church Rd
/2
M ile
R d
M ile
R d
Elmer Rd
N P ar m a R d
N P ar m a R d
W Michigan Ave
N G ib bs
R d
N G ib bs
R d
Devereaux Rd
B ro w n
R d
B ro w n
R d
AREA OF WORK
E at o n
R ap id s
R d
W Main St
M ec ha ni c S t
2 3
M o nr o e S t
Oyer St
Grand St
P e ar
S t
E Main St Eaton Rapids Rd
Willow St
M ill S t
G re e n
S t
1 - SPRINGPORT FOOTBALL STADIUM
2 - SPRINGPORT MIDDLE SCHOOL
3 - SPRINGPORT HIGH SCHOOL & ELEMENTARY SCHOOL
4 - SPRINGPORT TRANSPORTATION BUILDING
5 - SPRINGPORT AGRICULTURE BUILDING
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
DESIGN TEAM
ARCHITECT/ENGINEER
/2
/2
:1 :0
P
M
SPRINGPORT HIGH SCHOOL &
ELEMENTARY SCHOOL
SPRINGPORT PUBLIC SCHOOLS
SPRINGPORT PUBLIC SCHOOLS
300 WEST MAIN STREET SPRINGPORT, MI 49284
BP#2 - CONSTRUCTION DOCUMENTS
C O
V E
R S
H E
E T
.0
G
S P
R
IN
G P
O R
T H
IG
H
S C
H O
O L
E
L E
M E
N T
A R
Y S
C H
O O
L
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
W E
S T
M A
IN
S
T R
E E
T S
P R
IN
G
P O
R T
M
I
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
A U
G U
S T
D R
A W
N B
Y
X X
X
VILLAGE MAP
CAMPUS MAP
CONSTRUCTION MANAGER
211 E WATER ST. SUITE 201
KALAMAZOO, MI 49007
PHONE: 269.910.1347
REFERENCED CODES
BUILDING:
ENERGY:
PLUMBING:
MECHANICAL:
FUEL GAS:
ELECTRICAL:
BARRIER-FREE:
USE GROUP:
CONSTRUCTION TYPE:
AUTOMATIC SPRINKLERS:
2021 MICHIGAN BUILDING CODE AND 2012 NFPA 101 LIFE SAFETY CODE
2021 MICHIGAN ENERGY CODE
2021 MICHIGAN PLUMBING CODE
2021 MICHIGAN MECHANICAL CODE
(IFGC) 2021 INTERNATIONAL FUEL GAS CODE
2023 NATIONAL ELECTRICAL CODE WITH MICHIGAN AMENDMENTS
2021 MICHIGAN BUILDING CODE AND 2017 ICC & C A117.1
E, A2, A4
IIB, IIIB
EXISTING ELEMENTARY - NON-SPRINKLED
PROJECT AREA
EXISTING BUILDING: 153,054 SF
EXISTING GYM BEING DEMOLISHED: 8,374 SF
242 E KALAMAZOO AVE. SUITE 100
KALAMAZOO, MICHIGAN 49007
PHONE: 269.343.6133
FAX: 269.343.6633
GYM & CORRIDOR ADDITION: 17,191 SF
ISSUED FOR DATE
PROPOSED ADDITION & RENOVATION - SPRINKLED
VOLUME - 1
NOTE:
MOUNT EQUIPMENT AS SHOWN UNLESS SPECIFIED OTHERWISE.
MAX TWO DEVICES IN ONE HIGHER MOUNT
LOCATION AT LATCH SIDE OF DOOR, PROVIDE RFI
IF MORE DEVICES ARE NECESSARY. WHERE THERE
IS ONE DEVICE, CENTER OVER LOWER DEVICE. (TO
BE WITHIN ADA HEIGHT). (IF SWITCH CANNOT BE
LOCATED ON LATCH SIDE, LOCATE ONE DOOR
LEAF AWAY ON HINGE SIDE.)
DOOR
LOW DEVICES
RECEPTACLEVOICE/DATA
MASONRY COURSING
(WHERE APPLICABLE)
LIGHT SWITCH
F.A. AUDIO/VISUAL
ALIGNMENT NOTES
• ALIGN AND LOCATE CLOSE TOGETHER ANY DEVICES INSTALLED WITHIN 6' HORIZONTALLY.
• CENTER ALL DEVICES WHERE INDICATED ON COLUMN WRAP OR BUMP OUT; STACK AND ALIGN VERTICALLY.
• INSTALL DEVICES AT HEIGHTS INDICATED IN SYMBOL LEGEND UNLESS STACKING PER THIS DETAIL.
• WHERE HEIGHT IS SPECIFICALLY NOTED ON FLOOR PLANS, USE THAT MOUNTING HEIGHT
• CENTER ON DOORFRAME OR WHITEBOARDS ANY DEVICES INDICATED ABOVE.
O R L
A N D
IN
G
FR
O M
F
LO
O R
FR
O M
F
LO
O R O
R L
A N D
IN
G
6' - 0" MIN.
4" MAX
CAMERAS, CLOCKS, WALL
OCCUPANCY SENSORS
WHITE BOARD (WHERE APPLICABLE -
VERIFY WITH DETAILS/PLANS PROPER
INSTALL HEIGHT) CENTER ANY SINGLE
DEVICE WITH CENTER OF WHITE BOARD
ANY DEVICES
SHOWN OVER DOOR
TO BE CENTERED.
EQ EQ
EQ EQ
FR
O M
F
LO
O R O
R L
A N D
IN
G
SHORT THROW PROJECTOR
WHERE APPLICABLE
~12"
FA PULL STATION - HINGE SIDE
OF DOOR 1-LEAF AWAY WITHIN
5'-0" OF EXTERIOR OR STAIR
DOORS, WHEN WALL MOUNT
STROBES ARE ON PROJECT,
ALIGN ABOVE.
WHEN DEVICES ARE WITHIN DIMENSION, STACK
HIGH/LOW VERTICALLY AND GROUP DEVICES AT
SAME HEIGHT. UNLESS DEVICES IS PART OF
TECHNOLOGY DETAIL GROUPING OR SERVING A
FURNITURE GROUP.
CASEWORK, COORDINATE DEVICE BOTTOM
TO BE 2" OVER BACKSPLASH OR OVER
COUNTERTOP (IF NO BACKSPLASH). FOR
LARGE FORMAT TILE, ALIGN EDGE OF DEVICE
WITH HORIZONTAL GROUT LINE CLOSEST TO
COUNTERTOP.
COORDINATE OUTLET LOCATIONS WITH
GROUT LINES, EDGE OF DEVICE ON GROUT
LINE IF POSSIBLE. COORDINATE WITH
INTERIOR DESIGN DRAWINGS.
TYPICAL COLUMN
ENCLOSURE, CHASE OR
BUMP-OUT WITH DEVICES
INDICATED IN PLANS.
EQ EQ
EQEQEQEQ
THERMOSTAT,
SENSORS OR AV
CONTROLLER, CARD
READER, ETC.
DEVICES TO BE 4" MAX DISTANCE APART
B1
I 101
A 301
A
A 311
A 00A-1
A 321
ROOM NUMBER
SHEET NUMBER
DETAIL NUMBER
ROOM NAME
100'-0" : 100'-0"
DISTANCE IN THE "X" DIRECTION FROM THE "Y" BASE LINE
DISTANCE IN THE "Y" DIRECTION FROM THE "X" BASE LINE
TYPICAL SYMBOLS AND REFERENCES
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
SECTION NUMBER
SHEET NUMBER
ELEVATION LETTER
SHEET NUMBER
ELEVATION NUMBER
BARRIER-FREE
REVISION IDENTIFIER (ADDENDUM AND BULLETIN)
COLUMN BUBBLE AND LINE
ELEVATION TAG FOR FLOOR PLANS AND
ELEVATION TAG FOR EXTERIOR
ELEVATIONS AND BUILDING SECTIONS
REFLECTED CEILING PLANS
ELEVATION TAG FOR FLOOR PLANS AND
ELEVATION TAG FOR EXTERIOR
ELEVATIONS AND BUILDING SECTIONS
REFLECTED CEILING PLANS
SHEET NUMBER
ELEVATION NUMBER
DOOR NUMBER - CORRESPONDS
TO THE ROOM NUMBER
LETTER DESIGNATES MORE THAN ONE IN ROOM
FINISH FLOOR
ELEVATION 100'-0"
FINISH FLOOR
ELEVATION 100'-0"
100'-0"
100'-0"
NOTE:
ROOM NAMES AND NUMBERS ON PLANS ARE
FOR CONSTRUCTION PURPOSES ONLY.
COORDINATE WITH OWNER REGARDING
PROPOSED NUMBERS FOR ALL SIGNAGE,
SCHEDULE AND PANEL DESIGNATIONS.
DETAIL REFERENCE BUBBLE
DETAIL REFERENCE BUBBLE
BUILDING SECTION REFERENCE BUBBLE
EXTERIOR ELEVATION REFERENCE BUBBLE
INTERIOR ELEVATION REFERENCE BUBBLE
ELEVATION TAG - EXISTING
ELEVATION TAG - NEW
U N
IT
A
U N
IT
B
ROOM NAME
A101A
A 502
ROOM IDENTIFICATION TAG
UNIT MATCHLINES
DETAIL TITLE
TYPICAL NOTATION SYMBOLS
ELEVATION AND SECTION REFERENCE SYMBOLS
WORKING POINT LAYOUT TAG
BORROWED LIGHT AND DOOR IDENTIFICATION
SYMBOLS
DETAIL TITLE
1" = 0'-1"
A 101
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L
L R
IG
H
T S
R E
S E
R V
E D
/2
/2
:5 :0
P
M
T Y
P
IC
A L S
Y M
B O
L S
A N
D R
E F
E R
E N
C E
S
A B
B R
E V
IA
T
IO
N
S
A N
D D
E V
IC
E
A L
IG
N
M E
N T
G U
ID
E
L
IN
E S
.0
G
S P
R
IN
G P
O R
T H
IG
H
S C
H O
O L
E
L E
M E
N T
A R
Y S
C H
O O
L
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
W E
S T
M A
IN
S
T R
E E
T S
P R
IN
G
P O
R T
M
I
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
A U
G U
S T
D R
A W
N B
Y
X X
X
SCALE: NONE
DEVICE ALIGNMENT GUIDELINES
LIST OF ABBREVIATIONS
ACP ACOUSTICAL PANEL CEILING
AFF ABOVE FINISH FLOOR
ALUM ALUMINUM
ANOD ANODIZED
CFMF COLD FORMED METAL FRAMING
CMU CONCRETE MASONRY UNIT
CONC CONCRETE
DCMU DECORATIVE CONCRETE MASONRY UNIT
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FRT FIRE RESISTANT TREATED
FV FIELD VERIFY
GYP BD GYPSUM BOARD
HM HOLLOW METAL
LVL LAMINATED VENEER LUMBER
MCM METAL COMPOSITE MATERIAL WALL PANEL
OC ON CENTER
PT PRESERVATIVE TREATED
PNT PAINT
SS STAINLESS STEEL
SSM SOLID SURFACE MATERIAL
TYP TYPICAL
VIF VERIFY IN FIELD
WD WOOD
GENERAL NOTES - ARCHITECTURAL - NEW CONSTRUCTION
1 THE OWNER RESERVES THE RIGHT TO REMOVE ANY ITEM FROM THE PROJECT PRIOR TO
COMMENCEMENT OF CONTRACTED DEMOLITION WORK.
2 ALL EXISTING CONDITIONS SHOULD BE FIELD VERIFIED BEFORE WORK BEGINS.
3 DIMENSIONS GIVEN ARE ACTUAL AND ARE TO THE FACE OF MASONRY UNITS OR TO THE
FACE OF STUD FRAMING, UNLESS NOTED OTHERWISE.
4 DETAILS SHOWN ILLUSTRATE DESIGN INTENT, NOT ALL POSSIBLE CONDITIONS. FOR
CONDITIONS NOT SHOWN, USE DETAILS CLOSEST TO CONDITION IN QUESTION.
5 EXTEND ALL INTERIOR WALL PARTITIONS FROM FLOOR TO STRUCTURE/DECK ABOVE
UNLESS NOTED OR DETAILED OTHERWISE.
6 WITHIN BUILDING INTERIOR PROVIDE BULLNOSE BLOCK IN CMU WALL ASSEMBLIES AT
ALL EXPOSED OUTSIDE CORNERS, INCLUDING WINDOW AND DOOR JAMBS, UNLESS
NOTES OR DETAILED OTHERWISE. PROVIDE SQUARE CORNERS AT ALL LOCATIONS
FINISHED WITH WALL TILE, REFER TO FINISH PLANS (I100 SHEETS) FOR LOCATIONS.
7 TOOTH-IN MASONRY AT NEW OPENINGS IN EXISTING WALLS.
8 TOOTH-IN NEW MASONRY INFILL INTO EXISTING OPENINGS AT ALL BULLNOSE BLOCK
LOCATIONS.
9 STUD WALLS SPANNING OVER 12'-0" IN HEIGHT SHALL BE A MINIMUM OF 20 GAGE.
10 DOORS ARE TO BE 4" FROM CORNER OF ROOM, UNLESS NOTED OR DIMENSIONED
OTHERWISE.
11 FIRESTOP ALL INTERCONNECTIONS BETWEEN VERTICAL AND HORIZONTAL SPACES AND
CONCEALED WALL SPACES AT CEILING, FLOOR AND ROOF LEVELS.
12 FIRESEAL ALL PENETRATIONS, SUCH AS, PIPES, DUCTS, CONDUITS, ETC. THROUGH FIRE
AND/OR SMOKE RATED ASSEMBLIES.
13 FOR CONTROL JOINT (C.J.) LOCATIONS REFER TO EXTERIOR ELEVATIONS AND/OR FLOOR
PLANS.
14 PAINT ALL ELECTRICAL PANEL COVERS AND ACCESS PANELS TO MATCH ADJACENT
FINISHES. USING OIL-BASED PAINT, NOT LATEX WALL PAINT.
15 PROVIDE WOOD BLOCKING IN WALLS THAT REQUIRE WALL MOUNTED EQUIPMENT OR
ACCESSORIES. COORDINATE WITH EQUIPMENT OR ACCESSORY MANUFACTURER.
16 PROVIDE ALL ASSOCIATED CURBS FOR ROOF TOP EQUIPMENT AND MECHANICAL ROOF
TOP UNITS. LARGE VOIDS BELOW THE AIR HANDLING UNITS SHALL BE FILLED WITH
INSULATION AS SPECIFIED FOR NOISE CONTROL.
17 ALL EXISTING ROOF TOP PENETRATIONS BEING REMOVED REQUIRE ROOF PATCHING TO
MATCH EXISTING ADJACENT.
18 AT AREAS THAT REQUIRE DEMOLITION OF ADJACENT MATERIALS OR FINISHES FOR THE
INSTALLATION OF NEW WORK, THE DISTURBED ITEMS INTENDED TO BE EXISTING TO
REMAIN SHALL BE PATCHED OR RESTORED TO ORIGINAL CONDITION.
GENERAL NOTES - ARCHITECTURAL - DEMOLITION
1 CONTRACTORS ARE REQUIRED TO INSPECT/REVIEW THE EXISTING BUILDING PRIOR TO
RELATED DEMOLITION WORK. UNLESS NOTED OTHERWISE, REMOVAL OF ANY WALL,
FLOOR OR CEILING INCLUDES ALL GENERAL MECHANICAL AND ELECTRICAL ITEMS WHICH
ARE A PART OF, OR ATTACHED TO IT.
2 CONTRACTOR SHALL VERIFY ALL EXISTING JOB SITE CONDITIONS AND DIMENSIONS AND
BE RESPONSIBLE FOR THE SAME ADVISE CONSTRUCTION MANAGER OF ANY AND ALL
DISCREPANCIES.
3 PATCH FLOORS, WALLS AND CEILINGS DAMAGED DURING CONSTRUCTION AND
DEMOLITION AS REQUIRED. FINISH TO MATCH EXISTING.
4 ACCOMMODATE NEW CONSTRUCTION IF NOT INDICATED.
5 PROTECT ALL EXISTING FINISHES THROUGHOUT PROJECT.
6 REFER TO DEMOLITION ELEVATIONS, SECTIONS AND DETAILS FOR ADDITIONAL
INFORMATION.
7 REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL PLANS FOR
ADDITIONAL DEMOLITION NOTES.
8 SALVAGE ALL UNISTRUT AND PROTECT FOR RE-USE IN NEW CONSTRUCTION, IF
REQUIRED.
9 AT LOCATIONS OF REMOVED WALLS, ALL ASSOCIATED ITEMS ATTACHED TO THE WALL
ARE TO BE REMOVED. SUCH AS: DOORS, WINDOWS, FRAMES, MARKERBOARDS,
TACKBOARDS, TACK STRIPS, ETC.
ISSUED FOR DATE
.0
IG
K
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
/2
/2
:0
:4
P
M
C O
D E
R E
V
IE
W
.0
G
S P
R
IN
G P
O R
T H
IG
H
S C
H O
O L
E L E
M E
N T
A R
Y S
C H
O O
L
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
W E
S T
M A
IN
S
T R
E E
T
S P
R
IN
G P
O R
T
M I
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
A U
G U
S T
D R
A W
N B
Y
X X
X
2021 MICHIGAN REHABILITATION CODE SUMMARY
ALTERATION - ANY CONSTRUCTION OR RENOVATION TO AN EXISTING STRUCTURE OTHER THAN REPAIR OR ADDITION. ALTERATIONS ARE CLASSIFIED AS LEVEL 1, LEVEL 2 AND LEVEL 3
WORK AREA - THAT PORTION OR PORTIONS OF A BUILDING CONSISTING OF ALL RECONFIGURED SPACES AS INDICATED ON THE CONSTRUCTION DOCUMENTS. WORK AREA EXCLUDES OTHER PORTIONS OF THE BUILDING
WHERE INCIDENTAL WORK ENTAILED BY THE INTENDED WORK MUST BE PERFORMED AND PORTIONS OF THE BUILDING WHERE WORK NOT INITIALLY INTENDED BY THE OWNER IS SPECIFICALLY REQUIRED BY THIS
CODE.
ALTERATION - LEVEL 1 (MRC 602.1)
SCOPE - LEVEL 1 ALTERATIONS INCLUDE THE REMOVAL AND REPLACEMENT OR THE COVERING OF EXISTING MATERIALS, ELEMENTS, EQUIPMENT, OR FIXTURES USING NEW MATERIALS, ELEMENTS, EQUIPMENT, OR
FIXTURES THAT SERVE THE SAME PURPOSE.
ALTERATION - LEVEL 2 (MRC 603.1)
SCOPE - LEVEL 2 ALTERATIONS INCLUDE THE RECONFIGURATION OF SPACE, THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE
INSTALLATION OF ANY ADDITIONAL EQUIPMENT.
ALTERATION - LEVEL 3 (MRC 604.1)
SCOPE - LEVEL 3 ALTERATIONS APPLY WHERE THE WORK AREA EXCEEDS 50 PERCENT OF THE BUILDING AREA
CHANGE OF OCCUPANCY (MRC 605.1)
SCOPE - ANY ACTIVITY CLASSIFIED AS A CHANGE OF OCCUPANCY AS DEFINED IN CHAPTER 2. SHALL COMPLY WITH CHAPTER 10
MATERIALS AND METHODS (MRC 702.7)
ALL NEW WORK SHALL COMPLY WITH THE MATERIALS AND METHODS REQUIREMENTS IN THE INTERNATIONAL BUILDING CODE, INTERNATIONAL ENERGY CODE, INTERNATIONAL MECHANICAL CODE AND INTERNATIONAL PLUMBING CODE, AS APPLICABLE, THAT SPECIFY
STANDARDS, DETAIL OF INSTALLATION AND CONNECTION, JOINTS, PENETRATIONS, AND CONTINUITY OF ANY ELEMENT, COMPONENT OR
SYSTEM IN THE BUILDING.
ENERGY CONSERVATION, MINIMUM REQUIREMENTS (MRC 708.1)
LEVEL 1 ALTERATIONS TO EXISTING BUILDINGS OR STRUCTURES DO NOT REQUIRE THE ENTIRE BUILDING OR STRUCTURE TO COMPLY WITH THE ENERGY REQUIREMENTS OF THE INTERNATIONAL ENERGY
CONSERVATION. THE ALTERATIONS SHALL CONFORM TO THE ENERGY REQUIREMENTS AS THEY RELATE TO NEW CONSTRUCTION ONLY.
2021 MBC CODE SUMMARY / 2012 NFPA 101 CODE SUMMARY
EXISTING BUILDING - 153,054 SF
EXISTING GYM BEING DEMOLISHED - 8,375 SF
BUILDING GYM AND CORRIDOR ADDITION - 17,191SF
ADDITIONS ARE SEPARATED FROM THE EXISTING BUILDING WITH A FIRE WALL
OCCUPANCY
E (MBC 305) EDUCATION
A-2 (MBC 303.3) CAFETERIAS
A-4 (MBC 303.5) INDOOR SPORTS WITH SPECTATOR SEATING
ALLOWABLE HEIGHT (FEET) (MBC 504.3)
A & E = 75’ MAX SPRINKLERED (55' MAX NOT SPRINKLERED)
ALLOWABLE HEIGHT (STORIES) (MBC 504.4)
E = 3 STORIES SPRINKLERED (2 STORIES NOT SPRINKLERED)
A-2 = 3 STORIES SPRINKLERED (2 STORIES NOT SPRINKLERED)
A-4 = 3 STORIES SPRINKLERED (2 STORIES NOT SPRINKLERED)
ALLOWABLE AREA (MBC 506.2)
E = 58,000 SF - SINGLE STORY SPRINKLED, IIB CONSTRUCTION
E = 14,500 SF - SINGLE STORY NOT SPRINKLED, IIIB CONSTRUCTION
A-2 = 38,000 SF - SINGLE STORY, SPRINKLERED, IIB CONSTRUCTION
A-4 = 38,000 SF - SINGLE STORY, SPRINKLERED, IIB CONSTRUCTION
REQUIRED SEPARATION OF OCCUPANCIES (HOURS) (MBC 508.4)
E/A = NO SEPARATION REQUIREMENT
CONSTRUCTION TYPE (MBC CH 6)
IIB (MBC CH6)
FIRE-RESISTANCE RATING FOR BUILDING ELEMENTS (MBC TABLE 601)
TYPE IIB CONSTRUCTION
PRIMARY STRUCTURE 0 HOUR
BEARING WALLS
INTERIOR 0 HOUR
EXTERIOR 0 HOUR
NONBEARING WALLS AND PARTITIONS (MBC TABLE 602)
EXTERIOR 0 HOUR (10’-30’)
FLOOR CONSTRUCTION 0 HOUR
ROOF CONSTRUCTION 0 HOUR
FIRE RESISTANT RATING REQUIREMENTS FOR EXTERIOR WALLS (TABLE 705.5)
IIB - OCCUPANCIES A & E - O HOURS
FIRE WALL FIRE RESISTANCE RATINGS (MBC TABLE 706.4)
OCCUPANCIES A & E NEED 2 HOUR FIRE WALLS
HORIZONTAL CONTINUITY (MBC TABLE 706.5)
FIRE WALLS SHALL BE CONTINUOUS AND EXTEND PAST EXTERIOR WALL NOT LESS THAN 18 INCHES
EXCEPTION 2 - AT NON COMBUSTIBLE EXTERIOR WALL, THE RATING CAN EXTEND 4 FEET HORIZONTALLY ON BOTH SIDES OF THE FIRE WALL
VERTICAL CONTINUITY (MBC TABLE 706.6)
FIRE WALLS SHALL EXTEND FROM THE FOUNDATION TO A TERMINATION POINT NOT LESS THAN 30 INCHES ABOVE THE
ADJACENT ROOFS
EXCEPTIONS:
WALLS SHALL BE PERMITTED TO TERMINATE AT THE UNDERSIDE OF NONCOMBUSTIBLE ROOF SHEATHING, DECK OR SLABS WHERE
BOTH BUILDINGS ARE PROVIDED WITH NOT LESS THAN A CLASS B ROOF COVERING. OPENINGS IN THE ROOF SHALL NOT BE LOCATED
WITHIN 4 FEET OF THE FIRE WALL.
FIRE PARTITIONS (MBC 708.1)
CORRIDOR WALLS PER SECTION 1020.3
INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY (MBC TABLE 803.13)
OCCUPANCY GROUPS E - SPRINKLERED
CLASS B - INTERIOR STAIRWAYS AND RAMPS AND EXIT PASSAGEWAYS
CLASS B - CORRIDORS AND ENCLOSURE FOR EXIT ACCESS STAIRWAYS AND RAMPS
CLASS C - ROOMS AND ENCLOSED SPACES
OCCUPANCY GROUPS A - SPRINKLERED
CLASS B - INTERIOR STAIRWAYS AND RAMPS AND EXIT PASSAGEWAYS
CLASS B - CORRIDORS AND ENCLOSURE FOR EXIT ACCESS STAIRWAYS AND RAMPS
CLASS C - ROOMS AND ENCLOSED SPACES
FIRE ALARM AND DETECTION SYSTEMS (MBC 907.2.3 GROUP E)
A MANUAL ALARM SYSTEM THAT INITIATES THE OCCUPANT NOTIFICATION SIGNAL UTILIZING AN EMERGENCY VOICE/ ALARM
COMMUNICATION SYSTEM MEETING THE REQUIREMENTS OF SECTION 907.5.2.2 AND INSTALLED IN ACCORDANCE WITH SECTION
907.6 SHALL BE INSTALLED IN GROUP E OCCUPANCIES. WHERE AUTOMATIC SPRINKLER SYSTEMS OR SMOKE DETECTORS ARE
INSTALLED, SUCH SYSTEMS OR DETECTORS SHALL BE CONNECTED TO THE BUILDING FIRE ALARM SYSTEM.
MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT (MBC 1004.5)
EDUCATION CLASSROOM - 1/20 SF NET
EDUCATION VOCATIONAL - 1/50 SF NET
EDUCATION LOCKER ROOM - 1/15 GROSS
ASSEMBLY - 1/5 SF NET STANDING SPACE
ASSEMBLY - 1/15 SF NET UNCONCENTRATED TABLES AND CHAIRS
BUSINESS AREAS - 150 GROSS
STORAGE - 1/300 GROSS
NUMBER OF EXITS OR ACCESS TO EXITS (MBC TABLE 1006.3.3)
OCCUPANT LOAD PER STORY = 1-500 OCCUPANTS = 2 EXITS MINIMUM PER STORY OR ACCESS TO EXITS PER STORY
PANIC AND FIRE HARDWARE (MBC 1010.2.9)
DOORS SERVING ROOMS OR SPACES WITH AN OCCUPANT LOAD OF 50 OR MORE IN GROUP A & E OCCUPANCY SHALL NOT BE PROVIDED WITH A LATCH OR LOCK OTHER THAN PANIC HARDWARE OR FIRE EXIT
HARDWARE.
EXIT ACCESS TRAVEL DISTANCE (TABLE 1017.2)
200’ MAX OCCUPANCY A & E (MBC TABLE 1017.2 UNSPRINKLERED)
250’ MAX OCCUPANCY A & E (MBC TABLE 1017.2 SPRINKLERED)
CORRIDOR FIRE RESISTANCE RATING (MBC TABLE 1020.1)
1 HOUR
0 HOUR RATING WITH SPRINKLERS PER 903.3.1.1 OR 903.2.1.2
CORRIDORS WIDTH AND CAPACITY (MBC TABLE 1020.2)
72” MINIMUM REQUIRED IN GROUP E WITH 100 OR MORE OCCUPANTS
DEAD ENDS (MBC TABLE 1020.5)
WHERE MORE THAN ONE EXIT OR EXIT ACCESS DOORWAY IS REQUIRED, THE EXIT ACCESS SHALL BE ARRANGED SUCH THAT THERE ARE NO DEAD ENDS IN CORRIDORS MORE THAN 20 FEET IN LENGTH.
COMMON PATH OF TRAVEL (MBC 1030.8)
OCCUPANCY A & E: 30 FEET FROM ANY SEAT TO A POINT WHERE AN OCCUPANT HAS A CHOICE OF TWO PATHS
50 FEET IN SMOKE PROTECTED OPEN AIR ASSEMBLY SEATING
75 FEET COMMON PATH IS ALLOWED WITH LESS THAN 50 OCCUPANTS
SERVICES (MBC 1109.2.1)
IF A SERVICE OR FACILITY IS PROVIDED IN AN AREA THAT IS NOT ACCESSIBLE, THE SAME SERVICE OR FACILITY SHALL BE PROVIDED ON AN ACCESSIBLE LEVEL AND SHALL BE ACCESSIBLE.
WHEELCHAIR SPACES (MBC 1109.2.2)
IN ROOMS AND SPACES USED FOR ASSEMBLY PURPOSES WITH FIXED SEATING, ACCESSIBLE WHEELCHAIR SPACES SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS 1108.2.2.1 AND 1108.2.2.3
2021 MICHIGAN PLUMBING CODE
TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES
ACTUAL OCCUPANT LOAD FOR PLUMBING FIXTURES (MPC 403.1 EXCEPTION. NO.1)
SPRINPGORT ELEMENTARY SCHOOL: PLUMBING FIXTURE COUNT IS BASED ON ACTUAL OCCUPANT LOAD = 489 OCCUPANTS (457 STUDENTS + 32 STAFF)
WATERCLOSETS (MPC 403.1)
SPRINGPORT ELEMENTARY SCHOOL:
1 PER 50 - E OCCUPANCY
489 TOTAL OCCUPANTS / 2 = 245/ 50 = 4.9 = 5
REQUIRED – (10 TOTAL) - 5 WCs FOR BOTH MEN AND WOMEN
PROVIDED – (27 TOTAL) - 6 WCs FOR MEN & 14 WCs FOR WOMEN (20 WCs AND 7 URs)
URINALS (MPC 424.2) SUBSTITUTION FOR WATER CLOSETS.
IN EACH BATHROOM OR TOILET ROOM, URINALS SHALL NOT BE SUBSTITUTED FOR MORE THAN 67 PERCENT OF THE REQUIRED WATER CLOSETS IN ASSEMBLY AND
EDUCATIONAL OCCUPANCIES. URINALS SHALL NOT SUBSTITUTE FOR MORE THAN 50 PERCENT OF THE REQUIRED WATER CLOSETS IN ALL OTHER OCCUPANCIES.
LAVATORIES (MPC 403.1)
SPRINGPORT ELEMENTARY SCHOOL:
1 PER 50 - E OCCUPANCY
489 TOTAL OCCUPANTS / 2 = + 245/ 50 = 4.9 = 5
REQUIRED – (10 TOTAL) – 5 LAVs FOR BOTH MEN AND WOMEN
PROVIDED – (18 TOTAL) – 9 LAVs FOR MEN & 10 LAVs FOR WOMEN
DRINKING FOUNTAIN (MPC 403.1)
WAVERLY ECEC:
1 PER 100 REQUIRED - E OCCUPANCY
489 TOTAL OCCUPANTS / 100 = 4.8 = 5
REQUIRED – (5 TOTAL DFs)
PROVIDED – (7 TOTAL DFs) PLUS (1) BOTTLE FILLER
(MPC 410.4) SUBSTITUTION (FOR DRINKING FOUNTAINS)
IN OCCUPANCIES OTHER THAN RESTAURANTS WHERE DRINKING FOUNTAINS ARE REQUIRED, WATER DISPENSERS SHALL
BE PERMITTED TO BE SUBSTITUTED FOR NOT MORE THAN 50 PERCENT OF THE REQUIRED NUMBER OF DRINKING FOUNTAINS.
OTHER (MPC 403.1)
SPRINGPORT ELEMENTARY SCHOOL:
X SERVICE SINK REQUIRED
X SERVICE SINKS PROVIDED
ENERGY CODE
ASHRAE STANDARD 90.1 - 2019
TABLE 5.5-5 BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 5A
NONRESIDENTIAL
5.1.3 ENVELOPE ALTERNATIONS, EXCEPTION #5
THE ROOF ALTERATIONS NEED NOT COMPLY WITH THESE REQUIREMENTS, PROVIDED SUCH ALTERATIONS WILL NOT INCREASE THE ENERGY USAGE OF THE
BUILDING - #5 ROOF RECOVERING.
ROOFS INSULATION ENTIRELY ABOVE DECK
MAX U-0.032, MIN R-20 c.i. AT EXISTING ROOFS, MIN R-30 c.i. AT NEW ROOFS
WALLS ABOVE GRADE
MASS MAX U-0.090, MIN R-11.4 c.i.
STEEL FRAMED MAX U-0.055, MIN R-13 + R-10 c.i.
WALLS BELOW GRADE
MAX C-0.119, R-7.5 c.i.
FLOORS
MASS MAX U-0.057, MIN R-14.6 c.i.
STEEL JOIST MAX U-0.038, MIN R-30
SLAB ON GRADE FLOORS
HEATED MAX F-0.688, MIN R-15 FOR 24 IN.
OPAQUE DOORS
SWINGING MAX U-0.370
FENESTRATION - 0% TO 40% OF WALL
FIXED - MAX U-0.36, MAX SHGC-0.38
OPERABLE - MAX U-0.45, MAX SHGC-0.33
ENTRANCE DOOR - MAX U-0.63, MAX SHGC-0.33
SKYLIGHTS - 0% TO 3% OF ROOF
ALL TYPES - MAX U-0.50, MAX SHGC-0.40
ISSUED FOR DATE
DN DN
DN
M
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
T T
T T
TTT
T
T
T
M
M
UP
UP
U N
IT A
U N
IT K
U N
IT
A
U N
IT
B
U N
IT K
U N
IT J
U N
IT K
U N
IT J
U N
IT J
U N
IT H
U N
IT
H
U N
IT
G
U N
IT G
U N
IT F
U N
IT A
U N
IT G
U N
IT F
U N
IT E
U N
IT B
U N
IT C
U N
IT A
U N
IT B
U N
IT B
U N
IT C
U N
IT
J
U N
IT
C
U N
IT
F
U N
IT
E
U N
IT
F
U N
IT
D
U N
IT
F
U N
IT
D
PHASE 3
PHASE 3
P H A S E
TEMP WALLS
PHASE 2
OCCUPANCY PHASE 2
AUGUST 2027
OCCUPANCY PHASE 2
AUGUST 2027
OCCUPANCY PHASE 1
AUGUST 2027AUGUST 2027
TEMPORARY
CONSTRUCTION
FENCING
TEMPORARY
CONSTRUCTION
GATE
OCCUPANCY PHASE 3
DECEMBER 2028
OCCUPANCY PHASE 3
DECEMBER 2028
UNIT A UNIT B
UNIT A UNIT C
UNIT A UNIT K
UNIT K UNIT J
UNIT K UNIT J
UNIT J UNIT H UNIT H UNIT F
UNITG UNIT F
UNIT J UNIT H
UNIT F UNIT D
UNIT B UNIT C
UNIT B UNIT C
UNIT J UNIT H
UNIT F UNIT E
UNIT F UNIT D
T E M
P W
A L L
T E M
P W
A L L
T E M
P W
A L L
TEMP WALL
T E M
P W
A L L
TEMPORARY
CONSTRUCTION
FENCING
TEMPORARY
CONSTRUCTION
GATE
DEMO PHASE 1
NOVEMBER 2026
DEMO PHASE 2
SUMMER 2027
DEMO PHASE 2
SUMMER 2027
DEMO PHASE 2
SUMMER 2027
UNIT J UNIT C
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
/2
/2
:0
:3
P
M
P H
A S
IN
G
P L A
N
.0
G
S P
R
IN
G P
O R
T H
IG
H
S C
H O
O L
E L E
M E
N T
A R
Y S
C H
O O
L
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
W E
S T
M A
IN
S
T R
E E
T
S P
R
IN
G P
O R
T
M I
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
A U
G U
S T
D R
A W
N B
Y
X X
X
1" = 50'-0"
OVERALL FIRST FLOOR OCCUPANCY PLAN
1" = 50'-0"
OVERALL FIRST FLOOR DEMOLITION PHASING PLAN
DN
DN
UPUP
T T
T T
TTT
T
T
T
TS
TS
TS
TS
T S
M
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
1. ALL PENETRATIONS THROUGH A FIRE OR SMOKE RATED PARTITION SHOULD BE
SEALED WITH AN APPROVED U.L. RATED PRODUCT.
2. THE TOPS OF ALL FIRE RATED PARTITIONS SHALL BE SEALED TO THE
CONTINUOUS STRUCTURE ABOVE WITH A U.L. RATED SYSTEM OR ASSEMBLY.
3. WOOD BLOCKING IN FIRE-RATED PARTITIONS SHALL BE NON-COMBUSTIBLE
TREATED WOOD.
4. REFER TO SPECIFICATION U.L. RATING INFORMATION.
5. FIRE-RATED WALLS ENDING INTO AN ACOUSTICAL DECK MUST HAVE THE FLUTES
FILLED, REFER TO 'TOP OF WALL DETAIL AT ACOUSTIC DECK' SHOWN ON THIS
SHEET.
• FOR MASONRY WALLS THE MASON SHALL FILL VOIDS AND FIRE SPRAY WITH UL LISTED
MATERIAL.
• FOR STUD WALLS USE FIRE SAFING AND FIRE CAULK.
CODE COMPLIANCE KEY
TRAVEL DISTANCE TO EGRESS DOOR (T.D.)
PERMITTED MAXIMUM TRAVEL DISTANCE PER
CONDITION (P.T.D.)
DIRECTION OF EGRESS
FIRE SAFETY SYMBOLS
FIRE-RATING KEY
XFE
XFEC
FE
FEC
EXISTING FIRE EXTINGUISHER
EXISTING FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
AED
AUTOMATED EXTERNAL DEFIBRILLATOR (AED)
RECESSED CABINET
DESIGNATION RATING PRIORITY
3 HOUR 1
2 HOUR FIRE PARTITION - 708 2
1 HOUR FIRE PARTITION - 708 3
SMOKE RESISTANT 4
COORDINATE ALL REQUIRED DAMPERS WITH MECHANICAL.
T.D. - 100' - 0"
P.T.D. - 200' - 0"
COMMON PATH OF TRAVEL (C.P.T.)
DIRECTION OF EGRESS
C.P.T. - 50' - 0"
MAIN EGRESS EXIT SECONDARY EGRESS EXIT
SMOKE EVACUATION H HORIZONTAL EGRESS
CLASSROOM
A000A
ROOM NAME AND ROOM NUMBER
ROOM AREA
OCCUPANT LOAD FACTOR
OCCUPANT LOAD
1 HOUR FIRE BARRIER - 707 3
2 HOUR FIRE BARRIER - 707 2
2 HOUR FIRE WALL - 706 2
FIRE SAFETY SYMBOLS
REFERENCED CODE
KNOX KNOX BOX
PROJECT AREA
EGRESS
Door #
EGRESS ROOM
UNIT A
UNIT B
U N
IT B
U N
IT C
UNIT B UNIT C
U N
IT
J
U N
IT
C
U N
IT
A
U N
IT
B
U N
IT A
U N
IT K
U N
IT K
U N
IT J
U N
IT K
U N
IT J
U N
IT J
U N
IT G U
N
IT
J
U N
IT
F
U N
IT G
U N
IT F
U N
IT C
U N
IT G
U N
IT
F
U N
IT
E
U N
IT
F
U N
IT
E
UNIT F
UNIT E
U N
IT
F
U N
IT
E
HS MEDIA
CENTER
C352
CLASSROOM
C426
CLASSROOM
C241
CLASSROOM
C347
CLASSROOM
F112CLASSROOM
F111
CLASSROOM
C348
CLASSROOM
C412
CLASSROOM
C236
CLASSROOM
C235
FACULTY
D120
CLASSROOM
C384
CLASSROOM
C383
CLASSROOM
C314
CLASSROOM
C313
CLASSROOM
C379
CLASSROOM
C382
CLASSROOM
C386
WOOD
F119
CLASSROOM
F116
AG SCIENCE
F117
CLASSROOM
F113
CLASSROOM
F127
MECH.
F128
BAND
F108
CHOIR
F101
RECEPTION
D110
HIGH SCHOOL
GYM
H357
KITCHEN
H446
GYMNASIUM
C116
U. MICH
HEALTH
RECEPTION
C115
CLASSROOM
B121
CLASSROOM
B119
CLASSROOM
B118
CLASSROOM
B117
CLASSROOM
B122
CLASSROOM
B123 CLASSROOM
B125
CLASSROOM
B126
CLASSROOM
A415
CLASSROOM
A418
CLASSROOM
A289
CLASSROOM
A412
CLASSROOM
A403
ELEM. MEDIA
CENTER
J100
CLASSROOM
J102
CLASSROOM
J101
CLASSROOM
J109
CLASSROOM
J110
CLASSROOM
J111
CLASSROOM
J112
CLASSROOM
J113
CLASSROOM
K106
CLASSROOM
K105
CLASSROOM
K104
CLASSROOM
K107
CLASSROOM
K108
CLASSROOM
K103
CLASSROOM
K102
CLASSROOM
K101
CLASSROOM
K100
CLASSROOM
K111
CLASSROOM
K110
CLASSROOM
K109
CORRIDOR
C123
SCENE SHOP
G114
FEC
FEC
FEC
FEC
FEC
FEC
FEC
FEC
FEC
T.
D. -
113' - 0"
P.
T.
D. - 250' -
0"
T .D
P .T
.D
T .D
P .T
.D
T.
D. -
121' - 4"
P.
T.
D. -
250' - 0"
T .D
P .T
.D
ELEMENTARY SCHOOL EAST
CLASSROOM WING 2,499 SF TOTAL
UNSPRINKLED 10,145 LEVEL 2
ALTERATION 18% LEVEL 2 ALTERATION
E - NS - IIIB - 14,500 SF ALLOWED
GYMNASIUM 9,402 SF TOTAL SPRINKLED
A4 - S1 - IIB - 38,000 SF ALLOWED
CAFETORIUM 6,866 SF TOTAL SPRINKLED
A2 - S1 - IIB - 38,000 SF ALLOWED
XFEC
XFEC
XFEC
XFEC
XFEC
XFEC
XFEC
XFE
XFE
XFE
2-HOUR FIRE WALL
-H
O U R F
IR
E B
A R R
IE
R
-H
O U R F
IR
E W
A
LL
2-HOUR FIRE WALL
-H
O U R F
IR
E W
A
LL
2-HOUR FIRE WALL
-H
O U R F
IR
E B
A R R
IE
R
2-HOUR FIRE WALL
-H
O U R F
IR
E W
A
LL
C.P.T. - 64' - 6"
C.P.T. - 79' - 10"
C .P
.T
EGRESS
EGRESS
EGRESS
EGRESS
EGRESS
EGRESS
EGRESS
EGRESS
EGRESS340
E G
R E
S S
E G
R E
S S
E G
R E
S S
E G
R E
S S
E G
R E
S S
E G
R E
S S
E G
R E
S S
E G
R E
S S
E G
R E
S S
E G
R E
S S
COURTYARD
C200
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
/2
/2
:0
:3
P
M
O V
E R
A L
L C
O D
E C
O M
P L
IA
N C
E P
L A
N
.0
G
S P
R
IN
G P
O R
T H
IG
H
S C
H O
O L
E L E
M E
N T
A R
Y S
C H
O O
L
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
W E
S T
M A
IN
S
T R
E E
T
S P
R
IN
G P
O R
T
M I
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
A U
G U
S T
D R
A W
N B
Y
X X
X
THIS DRAWING SHEET IS INTENDED TO BE PLOTTED IN
COLOR. IF THIS TEXT APPEARS IN BLACK AND WHITE,
IT IS PLOTTED INCORRECTLY. DISCARD AND OBTAIN
AN ACCURATE DRAWING
BUILDING: 2021 MICHIGAN BUILDING CODE & 2012 NFPA 101 LIFE SAFETY
CODE
REHABILITATION 2021 MICHIGAN REHAB CODE 2021
ENERGY: 2021 MICHIGAN ENERGY CODE
PLUMBING: 2021 MICHIGAN PLUMBING CODE
MECHANICAL: 2021 MICHIGAN MECHANICAL CODE
FUEL GAS: (IFGC) 2015 INTERNATIONAL FUEL GAS CODE
ELECTRICAL: 2023 MICHIGAN ELECTRICAL CODE, PART 8
BARRIER FREE: 2021 MICHIGAN BUILDING CODE & 2017 ICC & C A117.1
USE GROUP: E (EDUCATION)
CONSTRUCTION TYPE: II B
SPRINKLERS: YES
ADDITION SF 16200 SF
1" = 30'-0"
OVERALL CODE COMPLIANCE PLAN
SPRINGPORT ELEMENTARY / HIGH SCHOOL
A B C D
KEY PLAN
SCALE: NO SCALE
EFG
H
J
F
U N
IT B
U N
IT C
CLASSROOM
B126
CLASSROOM
B121
CORRIDOR
B470
CLASSROOM
B119
CLASSROOM
B118
CLASSROOM
B117
CLASSROOM
B122
CLASSROOM
B123
CLASSROOM
B125
UNIT A
UNIT B
U
N
IT
A
U N
IT
B
U N
IT B
U N
IT C
FEC
-H
O U R F
IR
E W
A
LL
T .D
P .T
.D
T .D
P .T
.D
T .D
P .T
.D
EGRESS
EGRESS
EGRESS
COURTYARD
C200
ELEMENTARY SCHOOL EAST CLASSROOM
WING 2,499 SF TOTAL UNSPRINKLED
10,145 LEVEL 2 ALTERATION 18% LEVEL
2 ALTERATION
E - NS - IIIB - 14,500 SF ALLOWED
1. ALL PENETRATIONS THROUGH A FIRE OR SMOKE RATED PARTITION SHOULD BE
SEALED WITH AN APPROVED U.L. RATED PRODUCT.
2. THE TOPS OF ALL FIRE RATED PARTITIONS SHALL BE SEALED TO THE
CONTINUOUS STRUCTURE ABOVE WITH A U.L. RATED SYSTEM OR ASSEMBLY.
3. WOOD BLOCKING IN FIRE-RATED PARTITIONS SHALL BE NON-COMBUSTIBLE
TREATED WOOD.
4. REFER TO SPECIFICATION U.L. RATING INFORMATION.
5. FIRE-RATED WALLS ENDING INTO AN ACOUSTICAL DECK MUST HAVE THE FLUTES
FILLED, REFER TO 'TOP OF WALL DETAIL AT ACOUSTIC DECK' SHOWN ON THIS
SHEET.
• FOR MASONRY WALLS THE MASON SHALL FILL VOIDS AND FIRE SPRAY WITH UL LISTED
MATERIAL.
• FOR STUD WALLS USE FIRE SAFING AND FIRE CAULK.
CODE COMPLIANCE KEY
TRAVEL DISTANCE TO EGRESS DOOR (T.D.)
PERMITTED MAXIMUM TRAVEL DISTANCE PER
CONDITION (P.T.D.)
DIRECTION OF EGRESS
FIRE SAFETY SYMBOLS
FIRE-RATING KEY
XFE
XFEC
FE
FEC
EXISTING FIRE EXTINGUISHER
EXISTING FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
AED
AUTOMATED EXTERNAL DEFIBRILLATOR (AED)
RECESSED CABINET
DESIGNATION RATING PRIORITY
3 HOUR 1
2 HOUR FIRE PARTITION - 708 2
1 HOUR FIRE PARTITION - 708 3
SMOKE RESISTANT 4
COORDINATE ALL REQUIRED DAMPERS WITH MECHANICAL.
T.D. - 100' - 0"
P.T.D. - 200' - 0"
COMMON PATH OF TRAVEL (C.P.T.)
DIRECTION OF EGRESS
C.P.T. - 50' - 0"
MAIN EGRESS EXIT SECONDARY EGRESS EXIT
SMOKE EVACUATION H HORIZONTAL EGRESS
CLASSROOM
A000A
ROOM NAME AND ROOM NUMBER
ROOM AREA
OCCUPANT LOAD FACTOR
OCCUPANT LOAD
1 HOUR FIRE BARRIER - 707 3
2 HOUR FIRE BARRIER - 707 2
2 HOUR FIRE WALL - 706 2
FIRE SAFETY SYMBOLS
REFERENCED CODE
KNOX KNOX BOX
PROJECT AREA
EGRESS
Door #
EGRESS ROOM
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
/2
/2
:0
:3
P
M
F
IR
S T
F L
O O
R C
O D
E C
O M
P L
IA
N
C E
P L A
N
U N
IT
B
.0
G
B
S P
R
IN
G P
O R
T H
IG
H
S C
H O
O L
E L E
M E
N T
A R
Y S
C H
O O
L
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
W E
S T
M A
IN
S
T R
E E
T
S P
R
IN
G P
O R
T
M I
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
A U
G U
S T
D R
A W
N B
Y
X X
X
1/8" = 1'-0"
FIRST FLOOR CODE COMPLIANCE PLAN - UNIT B
SPRINGPORT ELEMENTARY / HIGH SCHOOL
A B C D
KEY PLAN
SCALE: NO SCALE
EFG
H
J
T
F
F
F
F
F
C .P
.T
U N
IT B
U N
IT C
GYMNASIUM
C116
ELEC.
C117
STORAGE
C118
STORAGE
C119
BOARD ROOM
C106
VESTIBULE
C100
VESTIBULE
C124
CORRIDOR
C123
OFFICE
C122
E.C.
C121
T.R.
C120
MEN'S
G100
CLASSROOM
B126
CLASSROOM
B121
CORRIDOR
B470
STORAGE
C185
CORRIDOR
C126
U N
IT B
U N
IT C
FEC
FEC
FEC
FEC
FEC
2-HOUR FIRE WALL
-H
O U R F
IR
E W
A
LL
2-HOUR FIRE WALL
-H
O U R F
IR
E B
A R R
IE
R
T .D
P .T
.D
T.
D. -
121' - 4"
P.
T.
D. -
250' - 0"
GYMNASIUM 9,402 SF TOTAL SPRINKLED
A4 - S1 - IIB - 38,000 SF ALLOWED
EGRESS
EGRESS
EGRESS
EGRESS
EGRESS
E G
R E
S S
E G
R E
S S
U N
IT
C
U N
IT
G
DRESSING
ROOM
G103
COURTYARD
C200
NONSTRUCTURAL DECORATIVE GLUE LAMINATED
ARCHES W/ INTUMESCENT PAINT FINISH TO MEET
CLASS C, ASTM E84 FINISH. REFER TO INTERIORS
FOR COLOR OF FINISH
1. ALL PENETRATIONS THROUGH A FIRE OR SMOKE RATED PARTITION SHOULD BE
SEALED WITH AN APPROVED U.L. RATED PRODUCT.
2. THE TOPS OF ALL FIRE RATED PARTITIONS SHALL BE SEALED TO THE
CONTINUOUS STRUCTURE ABOVE WITH A U.L. RATED SYSTEM OR ASSEMBLY.
3. WOOD BLOCKING IN FIRE-RATED PARTITIONS SHALL BE NON-COMBUSTIBLE
TREATED WOOD.
4. REFER TO SPECIFICATION U.L. RATING INFORMATION.
5. FIRE-RATED WALLS ENDING INTO AN ACOUSTICAL DECK MUST HAVE THE FLUTES
FILLED, REFER TO 'TOP OF WALL DETAIL AT ACOUSTIC DECK' SHOWN ON THIS
SHEET.
• FOR MASONRY WALLS THE MASON SHALL FILL VOIDS AND FIRE SPRAY WITH UL LISTED
MATERIAL.
• FOR STUD WALLS USE FIRE SAFING AND FIRE CAULK.
CODE COMPLIANCE KEY
TRAVEL DISTANCE TO EGRESS DOOR (T.D.)
PERMITTED MAXIMUM TRAVEL DISTANCE PER
CONDITION (P.T.D.)
DIRECTION OF EGRESS
FIRE SAFETY SYMBOLS
FIRE-RATING KEY
XFE
XFEC
FE
FEC
EXISTING FIRE EXTINGUISHER
EXISTING FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
AED
AUTOMATED EXTERNAL DEFIBRILLATOR (AED)
RECESSED CABINET
DESIGNATION RATING PRIORITY
3 HOUR 1
2 HOUR FIRE PARTITION - 708 2
1 HOUR FIRE PARTITION - 708 3
SMOKE RESISTANT 4
COORDINATE ALL REQUIRED DAMPERS WITH MECHANICAL.
T.D. - 100' - 0"
P.T.D. - 200' - 0"
COMMON PATH OF TRAVEL (C.P.T.)
DIRECTION OF EGRESS
C.P.T. - 50' - 0"
MAIN EGRESS EXIT SECONDARY EGRESS EXIT
SMOKE EVACUATION H HORIZONTAL EGRESS
CLASSROOM
A000A
ROOM NAME AND ROOM NUMBER
ROOM AREA
OCCUPANT LOAD FACTOR
OCCUPANT LOAD
1 HOUR FIRE BARRIER - 707 3
2 HOUR FIRE BARRIER - 707 2
2 HOUR FIRE WALL - 706 2
FIRE SAFETY SYMBOLS
REFERENCED CODE
KNOX KNOX BOX
PROJECT AREA
EGRESS
Door #
EGRESS ROOM
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
/2
/2
:0
:4
P
M
F
IR
S T
F L
O O
R C
O D
E C
O M
P L
IA
N
C E
P L A
N
U N
IT
C
.0
G
C
S P
R
IN
G P
O R
T H
IG
H
S C
H O
O L
E L E
M E
N T
A R
Y S
C H
O O
L
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
W E
S T
M A
IN
S
T R
E E
T
S P
R
IN
G P
O R
T
M I
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
A U
G U
S T
D R
A W
N B
Y
X X
X
1/8" = 1'-0"
FIRST FLOOR CODE COMPLIANCE PLAN - UNIT C
SPRINGPORT ELEMENTARY / HIGH SCHOOL
A B C D
KEY PLAN
SCALE: NO SCALE
EFG
H
J
DN
DN
T S
M
F
F
C.P.T. - 79' - 10"
C.P.T. - 64' - 6"
MEN'S
G100
CORRIDOR
C126
CAFETORIUM
G111
STAGE
G110
GREEN ROOM
G102
CHOIR
F101
COOLER
F129
FREEZER
F130
VENDING
G112
STORAGE
J108
OFFICE
J107
SCENE SHOP
G114
CUSTODIAL
G113
CLASSROOM
J109CLASSROOM
J110
MECH.
J103
OFFICE
J104
BOYS
J105
GIRLS
J106
T.R.
G104
TR
G105
STORAGE
G106
U N
IT G
U N
IT F
U N
IT J
U N
IT H
U N
IT
J
U N
IT
C
SERVING
H444
FEC
FEC
FEC
FEC
FEC
XFEC
XFEC
XFEC
2-HOUR FIRE WALL
-H
O U R F
IR
E B
A R R
IE
R
-H
O U R F
IR
E W
A
LL
2-HOUR FIRE WALL
2-HOUR FIRE WALL
-H
O U R F
IR
E W
A
LL
T.
D. -
113' - 0"
P.
T.
D. - 250' -
0"
E G
R E
S S
E G
R E
S S
E G
R E
S S
WOMEN'S
G101
DRESSING
ROOM
G103
U N
IT
H
U N
IT
F
1. ALL PENETRATIONS THROUGH A FIRE OR SMOKE RATED PARTITION SHOULD BE
SEALED WITH AN APPROVED U.L. RATED PRODUCT.
2. THE TOPS OF ALL FIRE RATED PARTITIONS SHALL BE SEALED TO THE
CONTINUOUS STRUCTURE ABOVE WITH A U.L. RATED SYSTEM OR ASSEMBLY.
3. WOOD BLOCKING IN FIRE-RATED PARTITIONS SHALL BE NON-COMBUSTIBLE
TREATED WOOD.
4. REFER TO SPECIFICATION U.L. RATING INFORMATION.
5. FIRE-RATED WALLS ENDING INTO AN ACOUSTICAL DECK MUST HAVE THE FLUTES
FILLED, REFER TO 'TOP OF WALL DETAIL AT ACOUSTIC DECK' SHOWN ON THIS
SHEET.
• FOR MASONRY WALLS THE MASON SHALL FILL VOIDS AND FIRE SPRAY WITH UL LISTED
MATERIAL.
• FOR STUD WALLS USE FIRE SAFING AND FIRE CAULK.
CODE COMPLIANCE KEY
TRAVEL DISTANCE TO EGRESS DOOR (T.D.)
PERMITTED MAXIMUM TRAVEL DISTANCE PER
CONDITION (P.T.D.)
DIRECTION OF EGRESS
FIRE SAFETY SYMBOLS
FIRE-RATING KEY
XFE
XFEC
FE
FEC
EXISTING FIRE EXTINGUISHER
EXISTING FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
AED
AUTOMATED EXTERNAL DEFIBRILLATOR (AED)
RECESSED CABINET
DESIGNATION RATING PRIORITY
3 HOUR 1
2 HOUR FIRE PARTITION - 708 2
1 HOUR FIRE PARTITION - 708 3
SMOKE RESISTANT 4
COORDINATE ALL REQUIRED DAMPERS WITH MECHANICAL.
T.D. - 100' - 0"
P.T.D. - 200' - 0"
COMMON PATH OF TRAVEL (C.P.T.)
DIRECTION OF EGRESS
C.P.T. - 50' - 0"
MAIN EGRESS EXIT SECONDARY EGRESS EXIT
SMOKE EVACUATION H HORIZONTAL EGRESS
CLASSROOM
A000A
ROOM NAME AND ROOM NUMBER
ROOM AREA
OCCUPANT LOAD FACTOR
OCCUPANT LOAD
1 HOUR FIRE BARRIER - 707 3
2 HOUR FIRE BARRIER - 707 2
2 HOUR FIRE WALL - 706 2
FIRE SAFETY SYMBOLS
REFERENCED CODE
KNOX KNOX BOX
PROJECT AREA
EGRESS
Door #
EGRESS ROOM
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
/2
/2
:0
:4
P
M
F
IR
S T
F L
O O
R C
O D
E C
O M
P L
IA
N
C E
P L A
N
U N
IT
G
.0
G
G
S P
R
IN
G P
O R
T H
IG
H
S C
H O
O L
E L E
M E
N T
A R
Y S
C H
O O
L
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
W E
S T
M A
IN
S
T R
E E
T
S P
R
IN
G P
O R
T
M I
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
A U
G U
S T
D R
A W
N B
Y
X X
X
1/8" = 1'-0"
FIRST FLOOR CODE COMPLIANCE PLAN - UNIT G
SPRINGPORT ELEMENTARY / HIGH SCHOOL
A B C D
KEY PLAN
SCALE: NO SCALE
EFG
H
J K
ISSUED FOR DATE
CAFETORIUM 6,866 SF TOTAL SPRINKLED
A2 - S1 - IIB - 38,000 SF ALLOWED
M
F
F
F
F
U N
IT
H
U N
IT
F
U N
IT J
U N
IT H
HIGH SCHOOL
GYM
H357
MENS TEAM
LOCKER ROOM
H356
WOMENS TEAM
LOCKER ROOM
H324
PASSAGE
H392
STAIR
H279
STAIR
H431
PASSAGE
H281
STORAGE
H355
PE/COACHES
OFFICE
H396
PE/COACHES
OFFICE
H393
STORAGE
C330
KITCHEN
H446
SERVING
H444
LOBBY
H442
LOBBY
H464
VESTIBULE
H462
VESTIBULE
H441
CORRIDOR
H479
XFEC
XFEC
E G
R E
S S
E G
R E
S S
E G
R E
S S
E G
R E
S S
1. ALL PENETRATIONS THROUGH A FIRE OR SMOKE RATED PARTITION SHOULD BE
SEALED WITH AN APPROVED U.L. RATED PRODUCT.
2. THE TOPS OF ALL FIRE RATED PARTITIONS SHALL BE SEALED TO THE
CONTINUOUS STRUCTURE ABOVE WITH A U.L. RATED SYSTEM OR ASSEMBLY.
3. WOOD BLOCKING IN FIRE-RATED PARTITIONS SHALL BE NON-COMBUSTIBLE
TREATED WOOD.
4. REFER TO SPECIFICATION U.L. RATING INFORMATION.
5. FIRE-RATED WALLS ENDING INTO AN ACOUSTICAL DECK MUST HAVE THE FLUTES
FILLED, REFER TO 'TOP OF WALL DETAIL AT ACOUSTIC DECK' SHOWN ON THIS
SHEET.
• FOR MASONRY WALLS THE MASON SHALL FILL VOIDS AND FIRE SPRAY WITH UL LISTED
MATERIAL.
• FOR STUD WALLS USE FIRE SAFING AND FIRE CAULK.
CODE COMPLIANCE KEY
TRAVEL DISTANCE TO EGRESS DOOR (T.D.)
PERMITTED MAXIMUM TRAVEL DISTANCE PER
CONDITION (P.T.D.)
DIRECTION OF EGRESS
FIRE SAFETY SYMBOLS
FIRE-RATING KEY
XFE
XFEC
FE
FEC
EXISTING FIRE EXTINGUISHER
EXISTING FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
AED
AUTOMATED EXTERNAL DEFIBRILLATOR (AED)
RECESSED CABINET
DESIGNATION RATING PRIORITY
3 HOUR 1
2 HOUR FIRE PARTITION - 708 2
1 HOUR FIRE PARTITION - 708 3
SMOKE RESISTANT 4
COORDINATE ALL REQUIRED DAMPERS WITH MECHANICAL.
T.D. - 100' - 0"
P.T.D. - 200' - 0"
COMMON PATH OF TRAVEL (C.P.T.)
DIRECTION OF EGRESS
C.P.T. - 50' - 0"
MAIN EGRESS EXIT SECONDARY EGRESS EXIT
SMOKE EVACUATION H HORIZONTAL EGRESS
CLASSROOM
A000A
ROOM NAME AND ROOM NUMBER
ROOM AREA
OCCUPANT LOAD FACTOR
OCCUPANT LOAD
1 HOUR FIRE BARRIER - 707 3
2 HOUR FIRE BARRIER - 707 2
2 HOUR FIRE WALL - 706 2
FIRE SAFETY SYMBOLS
REFERENCED CODE
KNOX KNOX BOX
PROJECT AREA
EGRESS
Door #
EGRESS ROOM
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
/2
/2
:0
:4
P
M
F
IR
S T
F L
O O
R C
O D
E C
O M
P L
IA
N
C E
P L A
N
U N
IT
H
.0
G
H
S P
R
IN
G P
O R
T H
IG
H
S C
H O
O L
E L E
M E
N T
A R
Y S
C H
O O
L
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
W E
S T
M A
IN
S
T R
E E
T
S P
R
IN
G P
O R
T
M I
S P
R
IN
G P
O R
T P
U B
L
IC
S C
H O
O L S
A U
G U
S T
D R
A W
N B
Y
X X
X
1/8" = 1'-0"
FIRST FLOOR CODE COMPLIANCE PLAN - UNIT H
SPRINGPORT ELEMENTARY / HIGH SCHOOL
A B C D
KEY PLAN
SCALE: NO SCALE
EFG
H
J
W W W W
Control Point (TBA)
996.50996.53
(BUS ONLY)(BUS ONLY) (BUS ONLY) (BUS ONLY) (BUS ONLY)
3" Ornamental Clump
3" Quad Ornamental C
DS
12" Pear
14" Pear
14" Pear(HCP PARK)(HCP PARK) 12" Pear 14" Pear 12" Pear
12" Pear
14" Pear
996.44
12" Maple996.53
997.45
997.20
DS
DS
14" MapleDS
DS
997.24
997.22
GM
997.20 14" Maple
ACAC
U 996.45C
DS
DS
CO 996.12
(STOP)
(SCHOOL ZONE)
GASG
(BUS ONLY)
WV
H
Y D995.12
12" HDPE
990.95
(ATHLETIC PARK)
(RESERVED PARK)(RESERVED PARK)(RESERVED PARK)(RESERVED PARK)(RESERVED PARK)(RESERVED PARK)(RESERVED PARK)(RESERVED PARK)(RESERVED PARK)(RESERVED PARK)(HCP PARK)
997.48997.47
14" Maple
997.51
DS
DS
AC
DS DS
DS
DS
995.90
995.84CO 995.64
DS
995.83
DS
DS
(SCH XING)
(HCP PARK)(HCP PARK)(HCP PARK)(HCP PARK)
P
HH
WV
H
Y D
DS
995.86995.85
DS DS
DS
22" Hickory
12" Cherry
10" Twin Cherry
DSDSDS
(ONE WAY)
(X WALK)GGAS
HH
FO
(X WALK)
H
Y DWV
WSO
18" Walnut
(SL 35)
Control Point (TBA)
Control Point (TBA)
Control Point (TBA)
H
Y D
998.74WV
(DRUG FREE)
(VISITOR PARK)
(VISITOR PARK)(VISITOR PARK)
(SP VILLAGE LIMIT)
(END SCH SPEED)
C P FO
(SL 35)
P
FO
HH
GASG
(CAUTION BUS) (CAUTION BUS)(CAUTION BUS)
10" Apple 10" Apple 12" Apple
30" Oak
WV
16" Oak12" Oak20" Oak16" Oak 22" Oak18" Oak12" Oak24" Oak18" Oak 30" Twin Oak
8" Oak28" Oak8" Hickory 12" Cherry 24" Oak24" Cherry 12" Hickory14" Twin Cherry12" Cherry14" Cherry
WV
H
Y D
EVENT PARK)
WV
H
Y D
(VISITOR PARK)
16" Cherry24" Twin Cherry10" Hickory6" Hickory18" Walnut16" Walnut20" Walnut8" Triple Cherry16" Walnut24" Walnut 8" Hickory
22" Cherry16" Hickory12" Hickory 20" Walnut
12" CMP
993.39
998.41998.45 P
998.55
998.45
(EVENT PARK)
(STOP)
(SL 10)
(NO PARK)
998.48
998.46
CO 996.06
H
Y D
998.65
WV
WV
(X WALK)
(X WALK)
HH
G
(SL 10)
(X WALK)
991.86
991.74
998.48
998.44
AC
AC
(SCOREBOARD)
22" Twin Pine
16" Twin Pine
18" Twin Pine 20" Pine
30" Pine
26" Pine
996.47
994.35
FO
HH
(NO PARK) (NO PARK) (NO PARK)
(YIELD)
992.34
993.59
994.29
994.26
991.66
991.07
(PU DO)
994.32
GM
DS
DS
FDC
12" Pine
12" Pine
998.69
14" Pine
12" Pine 8" Pine
14" Pine
14" Pine 18" Spruce
998.46998.46 998.53998.53998.54998.55998.50998.49998.51998.50
998.41998.43
HH
997.63
999.53999.55
EM
HH
12" Maple
1017.99
W
998.47
18" Maple
HH
12" HDPE
989.52
14" Pear 16" Pear(NO PARKING)
(NO PARKING)
18" Spruce
16" Pear12" stump
AC
DS
DS
(SL 35)
12" HDPE
989.70(STOP)
12" HDPE
990.83
P
(BUS ONLY)
20" Twin Oak14" Cherry 8" Cherry10" Cherry12" Twin Cherry
12" Poplar12" Poplar12" Poplar 18" Poplar18" Poplar
8" Poplar6" Poplar 18" Poplar16" Poplar16" PoplarP
8" Poplar16" Twin Cherry20" Triple Elm 6" Poplar
18" Poplar18" Twin Poplar 10" Poplar
18" Poplar12" Poplar16" Poplar16" Poplar14" Poplar18" Poplar16" Poplar6" Walnut
8" Triple Poplar
X X
XXX
X X
X
X
X X
X X
X X
X
X
X
X
X X
X
XX
X
X X
X X
X
X
XX
X X
X X
X X
X X
X
X X
X
X
XXX
X X
X X X X X X
X
XXX
X
X X
X X
X X
OE
OE
OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE OE
SD
994.20
SD
993.78
SS
SS
SS
SS
SS
SS
SS
SS
SS SS SS
SS
SS
SS
SD
SD SD SD SD
SD SD SD
SD
S
996.16
S
994.77
S
996.92
994.96
12" CMP
992.48
Control Point (TBA)
997.19
(PU DO)
WVH
Y D
997.85
997.16
997.13 997.16
(PU DO)
ST
993.75
DS
DS
997.18
DS
DS
(HCP)(HCP)
997.21
DS
DS
996.64
996.65 996.57
DS
997.13
CO996.08
AC
DS DS
997.49 Leach Basin
24" HDPE E, W - 984.23
24" HDPE N - 984.23
Leach Basin
24" HDPE E, W - 983.86
24" HDPE S - 987.84
12" HDPE N - 988.39
12" HDPE S, NW - 990.52
12" HDPE SE, N - 990.91
SD
994.12
994.07
994.56
ST
995.20
214912" HDPE NW, NNE - 988.66
12" S, NNW - 990.99
12" HDPE SSE - 991.35
Leach Basin
12" HDPE SSW, NW - 988.78
Leach Basin
12" HDPE SE - 989.38
Leach Basin
12" HDPE S - 989.74
Leach Basin
15" HDPE S - 989.40
12" HDPE N - 989.40
Leach Basin
15" HDPE E - 988.69
12" HDPE S - 988.69
15" HDPE N - 988.91
SD
12" HDPE N - 990.91
15" HDPE E, W - 987.40
12" HDPE N - 987.40
Leach Basin
12" HDPE S, N - 988.29
Leach Basin
12" HDPE S - 988.80
990.23
24" HDPE S - 986.43
15" HDPE N - 986.43
15" HDPE W - 987.03
15" HDPE S, N - 987.02991.17
SD
992.11
15" HDPE S - 987.63
12" HDPE N - 987.63
SD
SD
993.96
12" HDPE S - 987.79
12" HDPE W - 988.01
12" HDPE NE - 989.98
994.36
12" HDPE SW, NE - 991.06
12" HDPE E - 988.84
6" & 4" PVC NW - 989.35
6" PVC SE - 992.36
4" PVC W - 991.66
996.18
996.06
6" PVC SW - 992.68
6" PVC SE - 992.78
8" CLAY NE - 986.47
8" CLAY S, W - 986.57
4" PVC E - 989.74
6" PVC NW - 995.10
4" PVC S - 995.27
4" PVC S - 994.42
4" PVC N - 994.64
8" CLAY N - 987.60
8" CLAY SSE - 987.66
6" PVC E DROP:
LOWER - 988.04
UPPER - 992.62
996.21
8" HDPE W - 993.01
4" PVC E - 993.31
6" PVC SW - 993.91
6" PVC NE, W, S - 993.52
996.12
8" CLAY E - 985.58
8" CLAY SW - 985.71
SS SS SS SS SSS
995.45
Leach Basin
12" HDPE NE - 992.60
8" PVC SW - 992.60
995.05
Leach Basin
8" HDPE E - 989.56
12" HDPE SW - 991.06
SD
992.73
Leach Basin
12" HDPE NE, NW - 989.43
8" HDPE W - 989.43
991.90
12" HDPE SE - 989.85
Press Box Bleachers ramp ra mp ramp
Bleachers basketball hoop basketball hoop
Control Point (TBA)
G(SL 25)
14" Pine
22" Boxelder
12" Pine
26" Pine 26" Pine26" Pine
P
CP16" Cherry 12" Apple 18" Cherry
20" Twin Walnut (MULBERRY)" 24(MULBERRY)" 16(MULBERRY)" 20 8" Maple10" Cottonwood10" Hickory 24" Walnut
12" Twin Cherry14" Cherry10" Boxelder20" Boxelder 16" Boxelder20" Boxelder
10" Walnut 14" Boxelder10" Boxelder
14" Boxelder18" Boxelder20" Boxelder12" Quad Boxelder20" Boxelder12" Boxelder 14" Boxelder
16" Elm 24" Walnut
WSO
WVH
Y D
(EVENT PARK)
C
GM
EM
WV
NO UNAUTH VEH
STOP
48" stump
GM
10" Twin Cherry
995.80 P
995.90
DSDSDSDSDS
AC
AC
AC995.82
DS
DS
DS
AC
DS DS DS DS
995.74
994.74
(YIELD)
(SL15)
DSDS
995.75
DSDS
DS
995.81
DS
992.93
994.02
H
Y D
WV
996.58
DS
995.81995.79
(DUST VACUUM
989.76
989.77
989.66
990.15 990.18990.13990.11990.10990.14
DS
DSDSGM
FDC997.16
DS X
X
DS
997.23 997.20
CO 997.08
DS
(FIRE LANE)
989.79
990.14
990.12990.10990.12990.13 W
988.93
987.62
997.16997.15 997.16997.15
DSDSDSDSDSDS
WV
G
995.17995.26995.41
DS
DS DS DS DS DS
E
P
996.02
GM
DS
991.75
8" Cherry
30" Cottonwood
18" Walnut
16" Walnut 12" Walnut12" Walnut
15" RCP
987.63
FO
P
12" HDPE
992.39
999.79
986.19
987.76
12" HDPE
988.59
12" Cherry 14" Pine
X
X X
X
X X
X
X X
X X
X
X
X
XXXXXXXXX
X X X
X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X X X X X X
X X
X X
X
XX
X X
X X
X X
X X
X X
X X
X X
X X
X
X X X X X X X X X X X X
X
XXXXXXXXX
X X
X X
X X
X X
X X
X X
X X
XX
X X
X X
X
X X
X X
X X
X X
X X
X X
X X
X
X X X X X X X X X X X X X X X X X X X X X X X X X X X
X
X X
X X
O E
O E
O E
O E
O E
Control Point (TBA)
995.23
996.14 DS
996.11
S
995.89 8030S
996.00
996.10
DS
996.13 996.12
DS
24" HDPE
986.36
DS
992.26 992.21992.25
DS
992.24 992.2322" Cottonwood24" Cottonwood
998.42
998.42
998.42
998.41 998.44998.43
998.44
18" Pine
998.40998.41
998.40998.39
GM
998.48
998.40998.41998.40X
P
(SCHOOL SL25)
20" Cherry24" Oak16" BoxelderP
20" Twin Oak
998.49998.47 998.48
8" Apple 998.46998.46
998.44
14" Cedar
16" Cedar
12" Pine
20" Pine
18" Pine
36" Oak
18" Oak 14" Elm
8" Oak 18" Oak18" Twin Oak
20" Oak14" Oak18" Twin Oak16" Triple Oak22" Cherry 24" Twin Oak
X
X X
X
X X
X
X X X
X
X X
X
X
X
X
X
X
X
X X
X X
X
X
X
OE OE generator standpipe
OE OE OE OE
trench drain scoreboard gate gate gate gate gate ga tega te ga te gate gate gate gate gate gate gate gate gate gat e gate scoreboard gate gate sign gate batting cage
North 14 Corner Section 19
T01S, R03W
W W W WW W W W W W
S89° 59' 55"W 1108.80'
S89° 59' 55"W 736.70'
N89° 49' 58"W 732.50'
S00° 38' 05"E 1185.22'
N89° 59' 55"E 1469.32'
N00° 38' 31"W 1183.07'
N89° 59' 55"E 1100.25'
N00° 13' 40"W 1183.01'
Sanitary Easement L 834, Pg 599
Sanitary Easement L 834, Pg 611
Springport Telephone Company Easement
.5
0'
1002 10
10051000999
6 99
0 98
994 995
5 995
995996
997 996
995995
991 99
990 99
7 996 99 6 99 7 997
994 99
996 997
100099
997 996 995 994 993 992 992 993
992 991 990 988 990 991 990
994 995
996995 994 993
995 994
992 993
997995
994995996
995994
991 992
992 993
994993
989990991992
996995
995996
0 98
1 9
993 993
C101 C102 C103 C104
BM 1
Springport Middle School
Springport High School and
Elementary School
BM 2
BM 3
BM 4
BM 5
W W
SS
S
994.27 6076S
992.75
SS
SS
SS
SS
SS
SS SS
S
996.08
S996.74
SD
SD SD
SD
SD
SD
SD
SD
SD
SS
SS
SS
SS
SS
SS
SS
SS
W W W W W W W W W W W W
OE OE
OE
water vault pump house
992.50
994.04
12" HDPE E, W - 991.64
NO VISIBLE INVERTS
SDST993.38
12" RCP E - 989.33
S 993.39
8" CLAY S - 984.35
8" CLAY W, SSW - 984.41
8" CLAY EAST - 984.60 12" RCP E - 990.54 12" RCP N, W - 990.50
12" RCP S, E, W - 990.50
S
994.04
993.50
993.34
12" HDPE SE, NW - 988.84991.74
WET WELL
8" CLAY N - 983.40
FORCE MAIN
PUMP HOUSE
(LOCKED)
FM
8" HDPE S - 990.21
12" HDPE SE - 990.31
12" HDPE SW - 990.46
8" HDPE NE - 990.46
992.16
12" HDPE SW, NE - 988.84992.34
S
993.80
8" CLAY NNE - 985.02
8" CLAY SW - 985.12
12" HDPE SW, NE, W - 988.86993.86
12" HDPE E - 990.67
6" HDPE SW - 990.77
8" HDPE N - 990.87
994.17
8" CLAY NE - 985.50
8" CLAY SW - 985.60
8" CLAY W - 985.95
S
994.20
8" CLAY NE - 985.78
8" CLAY W - 985.88
8" PVC E - 986.62
Bolted shut
S
993.52
SS SS
S
993.14
LEACH BASIN
993.14
12" HDPE SW, N - 989.44
12" HDPE E - 989.88991.38
12" HDPE S, W - 987.80
12" HDPE NE - 988.90
12" HDPE N, SE, W - 987.95
992.70
991.15
991.23
12" HDPE NW, NE - 988.23
12" HDPE E, W - 987.9312" HDPE E - 988.02
12" HDPE NW - 989.07994.22
12" HDPE SE, N - 991.83
8" HDPE NW - 992.58995.98
12" HDPE S - 992.24
8" HDPE NW - 992.64995.74
S
994.97
8" PVC E - 986.38
8" PVC NW - 986.48
8" PVC SE - 986.91
8" PVC W - 987.01
8" PVC N - 988.55
S
996.03
8" PVC S - 989.78
8" PVC N - 989.88
6" CLAY W - 990.16
LEACH BASIN
LEACH BASIN
8" CLAY E - 988.31
8" CLAY NW - 988.41
4" PVC S - 992.44
8" CLAY SE - 988.54
8" CLAY W - 988.64
S
996.40
SEPTIC TANK
6" PVC N - 990.14
6" PVC S - 990.24
8" CLAY NE - 989.50
8" CLAY W - 989.60
6" PVC S - 989.63
S
994.63
8" PVC E - 990.57
8" PVC W - 990.65
S
994.93
8" CLAY E - 992.34
6" CLAY W, N - 992.50
S
997.80
6" CLAY S - 993.48
6" CLAY W - 993.56
S
997.57
SD
SD
SD
ST
997.93
12" RCP NW, E, S - 991.46
12" RCP N, E - 992.37
ST
997.92
SD SD
6" HDPE E - 995.63 FILLED WITH SILT998.03
W
998.81
8" CLAY E - 987.85
8" CLAY SW - 987.94
4" STEEL SW - 992.60
8' DIA BRICK STRUCTURE
996.60
OUTLET CONTROL
FILLED WITH DEBRIS
water vault raised planter
Found Iron Cap #28414
Found rebar
Found Iron Cap #28414
Set Iron Cap #45494
Set Iron Cap #45494
Set Mag Nail in walk
12" HDPE E - 987.80
6" HDPE N, NW - 989.05
W
W W
W W
W
996.45
S996.64
GENERAL NOTES:
1. Coordinates are Michigan State Plane South based on MDOT CORS. Elevations are NAVD88 (Geoid 18) based on MDOT CORS.
2. Description per Sun Title Property Report File Number 312182, Effective Date: September 10, 2025 at 8:00 AM
Land situated in the County of Jackson, Township of Springport, State of MI and is described as follows:
Parcel 1:
Begin on the North line of Section 19, Town 1 South, Range 3 West, at a point 1918.53 feet South 89 degrees 30 minutes West of the Northeast corner of Section 19; thence South 89 degrees 30 minutes West, 737.60 feet on the North line of Section 19, to the North 1/4 corner of Section 19; thence North 89 degrees 31 minutes West 732.5 feet on the North line of Section 19; thence South 01 degree 08 minutes East
1195.64 feet; thence North 89 degrees 30 minutes East 1470.0 feet; thence North 01 degree 08 minutes West 1183.05 feet to the Point of Beginning.
38-000-01-191-126-001-01 and 38-000-01-19-201-003-00
Land situated in the County of Jackson, Township of Springport, State of MI and is described as follows:
Parcel 2:
Commencing at the Northeast corner of Section 19, Town 1 South, Range 3 West; thence South 89 degrees 30 minutes West 809.73 feet along the centerline of Landon Road to a point which is the Place of Beginning of this description; thence South 89 degrees 30 minutes West 1108 .80 feet along the centerline of Landon Road; thence South 1 degree 08 minutes East 1183.05 feet; thence North 89 degrees 30 minutes East 1100.40 feet parallel with the centerline of Landon Road; and thence North 0 degrees 45 minutes West 1183 .05 feet to the Place of Beginning of this description.
EXCEPT Commencing 809.73 feet West of the Northeast corner or Section 19, Town 1 South, Range 3 West, which point is the Northeast corner of ground deeded by Edison Haas to Springport Rural Agricultural School of Springport, Michigan, thence West 490 feet which is the Point of Beginning of this description, thence West 150 feet; thence South 350 feet; thence East 150 feet; thence North 350 feet to the Place or Beginning.
38-015-01-19-201-001-00
Land situated in the County of Jackson, Township of Springport, State of MI and is described as follows:
Commencing 809.73 feet West of the Northeast corner or Section 19, Town 1 South, Range 3 West, which point is the Northeast corner of ground deeded by Edison Haas to Springport Rural Agricultural School of Springport, Michigan, thence West 490 feet which is the Point of Beginning of this description, thence West 150 feet; thence South 350 feet; thence East 150 feet; thence North 350 feet to the Place or Beginning
38-015-01-19-201-002-00
3. Easements per Sun Title Property Report File Number 312182, Effective Date: September 10, 2025 at 8:00 AM
f. Right of way in favor of Consumers Power Company (now known as Consumers Energy), as recorded in Liber 702, Page 38, as to Parcel 2. (Affects the subject property, but unable to determine the route of the easement due to the vagueness of the description.)
g. Right of way in favor of County Drain Commissioner, as recorded in Liber 834, Page 599, as to Parcel 2. (Affects the subject property and shown hereon.)
h. Right of way in favor of County Drain Commissioner, as recorded in Liber 834, Page 611, as assigned to Village of Springport by Assignment of Easement recorded in Liber 2267, Page 46, as to Parcel 2. (Affects the subject property and shown hereon.)
i. Right of way in favor of Springport Telephone Company, as recorded in Liber 885, Page 587, as to Parcel 1. (Affects the subject property and shown hereon.)
4. BENCHMARKS:
Benchmark 1 ELEVATION: 998.74 (NAVD88) Upper northwest flange bolt of hydrant under the "E" in "EJIW", located on the south side of Main Street, ±250' northeast of the Middle School building main entrance.
Benchmark 2 ELEVATION: 998.65 (NAVD88) Upper southwest flange bolt of hydrant above the "W" in "WATEROUS", located ±60' northeast of the southeast Middle School building corner.
Benchmark 3 ELEVATION: 995.12 (NAVD88) Upper southwest flange bolt of hydrant above the "W" in "WATEROUS", located on the south side of Main Street, ±180' north of the Elementary School building main entrance.
Benchmark 4 ELEVATION: 997.85 (NAVD88) Upper southeast flange bolt of hydrant under the "1" in "1998", located ±60' north of the southwest High School gymnasium building corner.
Benchmark 5 ELEVATION: 996.58 (NAVD88) Upper southwest flange bolt of hydrant above the "W" in "WATEROUS", located on the south side of the High School building, ±60' southwest of the shop doors.
Symbol Legend Symbol Denotes
AC UNIT
BENCH
BENCHMARK
BOLLARD
CABLE RISER
CONIFEROUS TREE
DECIDUOUS TREE
DOWN SPOUT
ELECTRIC METER
FIRE DEPT CONNECTION
FLAG POLE
GAS METER
GAS VALVE
GUY ANCHOR
HANDHOLE
HYDRANT
LIGHT POLE
LIGHT POLE
CONC LIGHT POLE BASE ONLY
MAILBOX
PHONE RISER
PICNIC TABLE
POWER POLE
REFERENCE POINT
ROCK
SANITARY CLEANOUT
SANITARY MH
SECTION CORNER
SHRUB
SIGN
SIGN
STORM CB ROUND
STORM CB SQUARE
STORM FES
STORM MH
STUMP
UNKNOWN…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .