Production Test Procedure

Procedure was used during Production: Yes or No?Production Test Procedure Mo. 280C-PTP Rev. EComments
I.LOCAL PANEL TEST
1Verify that the local/remote switch located on the local panel is in the local position.
2Place oil heater switch in the on position, ensure approximately 4.2 amps is present.
3Place air heater switch in the on position, ensure approximately 8.7 amps is present.
4Start the unit by placing the Local Panel Prime/Run Switch to the Start position until the engine engages.
5Verify that the low oil pressure LED (LED 3) has turned off.
6Turn the APU on by placing the momentary APU on switch briefly in the On position. Verify that APU on LED (LED 5) on the Local Panel is illuminated.
7Let unit run for one minute. Ensure voltage has risen to approximately 28 volts.
8Shut down the unit by placing the Local Panel Prime/Run Switch to the off position until the engine stops.
9Start the unit by placing the Local Panel Prime/Run Switch to the Start position until the engine engages.
10Turn the APU on by placing the momentary APU on switch briefly in the On position. Verify that APU on LED (LED 5) on the Local Panel is illuminated.
11Press the Emergency Stop button.
12Verify that the APU has completely shut down and the APU on LED has turned off.
13Pull out the Emergency Stop Button.
14Start the unit by placing the Local Panel Prime/Run Switch to the Start position until the engine engages.
15Remove one (1) connector from the Oil Pressure sender and verify that the unit shuts down while Low Oil Pressure LED is illuminated.
16Re connect oil pressure sender.
17Start the unit by placing the Local Panel Prime/Run Switch to the Start position until the engine engages.
18Short the over Temperature Sender by grounding it. Verify the unit shuts down while the over temperature LED is illuminated.
II.REMOTE PANEL OPERATION
1Place the Local/Remote Switch on the Local Control Panel to the Remote position.
2Verify both Prime/Run switches are in the Off position.
3Verify Emergency Stop Switch is pulled out.
4Press the press to test lamps button (S6) on the Remote Panel and verify that all four (4) LEDs on the Remote Panel are illuminated, then release the button.
5Place oil heater switch in the on position, ensure approximately 4.2 amps is present.
6Place air heater switch in the on position, ensure approximately 8.7 amps is present.
7Place the Prime/Run Switch (S1) located on the Remote Panel to the Prime/Run position.
8Verify that the Low Oil Pressure LED located on the Remote Panel is illuminated.
9Start the unit by placing the Remote Panel Prime/Run Switch (S1) to the Start position until the engine engages.
10Verify that the Low Oil Pressure LED has turned off.
11Turn the APU on by placing the momentary APU On Switch (S4), located on the Remote Panel, briefly in the On Position and verify that the APU on LED located on the Remote Panel is illuminated. Voltmeter should be in the green range.
12Shut down the unit by placing the Remote Panel Prime/Run Switch to the off position until the engine stops.
13Start the unit by placing the Remote Panel Prime/Run Switch to the Start position until the engine engages.
14Turn the APU on by placing the momentary APU on switch briefly in the On position. Verify that APU on LED (LED 5) on the Remote Panel is illuminated.
15Press the Emergency Stop button.
16Verify that the APU has completely shut down and the APU on LED has turned off.
17Verify that the Low Oil Pressure LED turns on with in one (1) minute after the APU has completely shut down.
18Place Prime/Run Switch in Off position.
19Pull out the Emergency Stop Button.
II.A. LOW OIL PRESSURE FAULT, BATTLE-SHORT OPERATION
1Restart the unit by placing the Remote Panel Prime/Run Switch (S1) to the Start position until the engine engages.
2Lift the Battle-short Switch (S5) cover and engage the Battle-short Switch by placing it in the On position.
3Verify that the Battle-short and APU on LEDs have illuminated and that the voltmeter is in the green range.
4Remove one (1) connector from the Oil Pressure sender and verify that the unit remains running while Low Oil Pressure LED is illuminated.
5Reconnect the Oil Pressure sender.
II.B. OVER TEMPERATURE FAULT, BATTLE-SHORT OPERATIONA. LOW OIL PRESSURE FAULT, BATTLE-SHORT OPERATION
1Short the over Temperature Sender by grounding it.
2Verify that the high engine temperature LED has illuminated on the Local (LED4) and Remote Panels (while the over temperature sender is shorted) and the APU remains running.
3Remove jumper wire from the over-temperature sender unit.
III.HAND CRANK OPERATION
1Place the Local/Remote Switch on the Local Panel to the Local position.
2Verify the Local Panel Prime/Run Switch is in the Prime/Run position.
3Open the lid of the unit on the side opposite to the Local Control Panel.
4Hold fuel Solenoid in the down position
5і WARNING: THE FUEL SOLENOID MAY BE EXTREMELY HOT!
6While holding the Solenoid down insert the Hand Crank into the unit and turn counterclockwise until the engine engages. Remove the Hand Crank after the engine is engaged.
7After the engine has started, press the Manual Start Button located next to the Fuel Solenoid.
8Release the Fuel Solenoid.
9Turn the APU off by placing the Prime/Run Switch located on the Local Panel to the Off position.
10Verify that the APU has completely shut down and the APU on LED has turned off.
IV.NO LOAD TEST
1Run the APU at zero-percent (0%) rated load for thirty (30) minutes and verify that APU operates properly during that time. Check Voltage & Load measurements.
V.FIFTY PERCENT (50%) LOAD TEST
1Run the APU at fifty-percent (50%) rated load for thirty (30) minutes and verify that APU operates properly during that time. Check Voltage & Load measurements.
VI.ONE HUNDRED PERCENT (100%) LOAD TEST
1Run the APU at one hundred-percent (100%) rated load for four (4) hours and verify that APU operates properly during that time. Check Voltage & Load measurements.
VII.CURRENT LIMIT POWER TEST
1Apply load until the current limit feature engages and voltage drops to approximately 26 volts. Let unit run for one minute, measure voltage and current readings. Ensure engine does not bog down.
2Turn APU off by placing the Prime/Run Switch located on the Local Panel to the off position.
3Verify that the APU has completely shut down and the APU on LED (LED 5) has turned off.

Attachment 0005 - Production Test Procedure - 208C-PTP REV. E