This is a solicitation for medical equipment replacement issued by the Indian Health Service (IHS), Albuquerque Area Office, for the Ute Mountain Ute Service Unit (UMUSU) Nursing Department in Towaoc, Colorado. The solicitation will result in a firm-fixed price, one-time award to a single entity. Offers must be submitted for "Brand Name or Equal To" products, and all work must comply with federal, state, local, and IHS regulations with minimal schedule divergence and maximum protection of government personnel and property.

The required equipment includes six line items: three Accuvein AV500 Vein Viewers (handheld, compact, rechargeable lithium-ion battery, wipeable); one Welch Allyn Scale-Tronix Stand on Scale (low-profile platform with handrails and bariatric capacity); two GE MAC VU360 Resting ECG-EKG units (with adjustable rollable stand); two SECA Model 3741321004 Infant Scales (portable, 44 lb capacity); ten Masimo Rad-G Pulse Oximeters (handheld, portable, rechargeable, LCD display); and twelve Exergen EXN-124275S Hospital Grade Thermometers (handheld). Delivery is required to the Nursing Department at 232 Rustling Willow, Towaoc, CO 81334, and must commence no later than 10 days after award. Pricing must include unit prices and shipping and handling costs for each item. The NAICS code is 339112 and the PSC is 6515.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Medical Equipment Replacement

PO# ~TBD ~ Ute Mountain Ute Service Unit

Towaoc, Colorado

Purpose:

The Indian Health Service (IHS), Albuquerque Area Office (AAO), Ute Mountain Ute Service Unit (UMUSU) has a need for medical equipment that either need to be replaced or upgraded for the Nursing Department at UMUSU Towaoc, Colorado.

The solicitation will result in a Firm-fixed Price one time award to a single entity.

DESCRIPTION OF SUPPLIES:

The contractor shall be in accordance with all Federal, State, Local and I.H.S regulations and shall be made with minimal divergence from the schedule established and with minimum disturbance and maximum protection of government personnel, property and general public.

Offer will be only for “BRAND NAME or EQUAL TO” following specified items listed:

1) ITEM No: AV500

MANUFACTURER: Accuvein

PRODUCT NAME: Vein Viewer

QTY: 03

Specifications:

• Weight - less than equal to 10 oz, hand-held

• Size – compact ( 2” X 2.4” X 7.9”)

• Continuous Run Time

• Battery – Internal, rechargeable, Lithium ion 3.6V

• Components included – charging cradle

• Wipeable

2) ITEM No: 5002

MANUFACTURER: Welch Allyn Scale-Tronix

PRODUCT NAME: Stand on Scale

QTY: 01

Specifications:

• Low profile platform

• Incl. handrails

• Bariatric capacity

3) ITEM No: MAC VU360

MANUFACTURER: GE

PRODUCT NAME: Resting ECG - EKG

QTY: 02

Specifications:

• With adjustable, rollable stand

4) ITEM No: 3741321004

MANUFACTURER: SECA

PRODUCT NAME: Infant scale

QTY: 02

Specifications:

• Portable

• holds up to 44 lbs

5) ITEM No: 95164

MANUFACTURER: Masimo

PRODUCT NAME: Rad-G Pulse Oximeter

QTY: 10

Specifications:

• Handheld

• Portable

• Rechargeable batteries

• LCD display

6) ITEM No: EXN-124275S

MANUFACTURER: Exergen

PRODUCT NAME: Thermometer

QTY: 12

Specifications:

• Handheld

• Hospital grade

DELIVERY LOCATION

A total of 6 “BRAND NAME or EQUAL TO” medical equipment to the following Albuquerque Area Indian Health Service Unit:

Ute Mountain Ute Service Unit Nursing Department

ATTN: Tara Topaha, RN 232 Rustling Willow Towaoc, CO 81334

PRICING

Offers for the specified “BRAND NAME OR EQUAL TO” for the following items will be provided in the following format:

No Item# Product Name Qty Price

1) AV500 Accuview Vein Finder 3 Shipping & Handling

2) 5002 Welch Allyn Scale Tronic -

Bariatric 1 Shipping & Handling

3) MAC VU360 Resting ECG EKG 2 Shipping & Handling

4) 3741321004 SECA Infant Scale - portable 2 Shipping & Handling

5) 95164 Rad-G Pulse Oximeter 10 Shipping & Handling

6) EXN-124275S Exergen Thermometer 12 Shipping & Handling Total

PERIOD OF PERFORMANCE

The items required under this contract shall commence NLT than 10 days after award

NAICS: 339112

PSC: 6515

File details come from the government source that posted it. Updated .