These Specifications detail a federal solicitation for aluminum gas cylinders for the National Institute of Standards and Technology (NIST) Material Measurement Laboratory's Gas Sensing Metrology Group (GSMG). The procurement requires 80 empty 30 cu-ft Luxfer non-SGS aluminum compressed gas cylinders with packless CGA-350 brass valves, and optionally up to 50 empty 30 cu-ft Luxfer SGS or non-SGS aluminum compressed gas cylinders with packless CGA-660 stainless steel valves. The cylinders will be used to produce Primary Standard Materials (PSMs) for gas reference standards, specifically for carbon monoxide, nitric oxide, and sulfur dioxide gas mixtures.

Key specifications include cylinders being prepped and passivated by the vendor, with specific requirements for gas mixture stability and nitrogen blanket pressurization. Delivery is required within 120 days of award to NIST Gaithersburg, MD. The contractor must provide a factory acceptance test report for NIST review before shipment, and GSMG will conduct a leak test within a year of delivery, with the contractor required to replace any leaking cylinders within 30 days at their expense. The solicitation is a small business set-aside under NAICS code 325120 with a size standard of 1,200 employees.

View the file

Other files for this federal contract opportunity

Other files attached to Aluminum Gas Cylinders, newest first.
File Type Posted
Amended Specifications.pdf PDF
Amended Solicitation .pdf PDF
Provisions Clauses.pdf PDF
Request for Quotation.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SPECIFICATIONS

Aluminum Gas Cylinders

I. BACKGROUND

The Material Measurement Laboratory’s Gas Sensing Metrology Group (GSMG) of Chemical Science Division is committed to supporting the gas Standard Reference Materials (SRMs) and NIST-Traceable Reference Materials (NTRMs) programs. A key element of these programs is the accurate determination of the amount-of-substance of carbon monoxide, nitric oxide and sulfur dioxide.

To support the SRM and NTRM programs, GSMG is maintaining groups of Primary gas Standard Materials (PSMs). A great amount of PSMs are depleted and GSMG is in urgent need of producing replacement PSMs.

GSMG requires eighty (80) empty (size 30 cu-ft.) Luxfer non-SGS aluminum compressed gas cylinders with packless CGA-350 brass valves and, a maximum of fifty (50) empty (size 30 cu-ft.)

Luxfer SGS® or non-SGS aluminum compressed gas cylinders with packless CGA-660 stainless steel valves to make NIST Primary Standard Materials. All cylinders will be filled at NIST.

II. SPECIFICATIONS

The Contractor shall deliver eighty (80) empty (size 30 cy-ft.) Luxfer non-SGS compressed gas aluminum cylinders with the following specifications:

Item 1. Quantity eighty (80) new, empty Luxfer non-SGS compressed gas aluminum cylinders (size 30 cu-ft.) with ¾” tapered thread and new Ceodeux packless CGA-350 brass valves.

Cylinders shall be prepped and passivated by vendor to ensure stability of gas mixtures containing carbon monoxide in nitrogen balance. (Carbon monoxide mixture concentrations from 7ppm to 16%, to be filled by NIST). Cylinders to be shipped with a blanket of nitrogen @ 30psig.

III. DELIVERY

Delivery shall be within 120 days of award to NIST Gaithersburg, MD, Building 227 Room B103.

IV. SEPARATELY PRICED LINE ITEMS

1. A maximum of Fifty (50) new, empty SGS Luxfer compressed gas aluminum cylinders (size 30 cu-ft) with ¾” tapered threat and new Ceodeux packless CGA 660 stainless steel valves.

Cylinders to be prepped and passivated by vendor to ensure stability of gas mixtures containing Nitric oxide / sulfur dioxide in nitrogen balance. (Nitric oxide mixture concentrations from 0.7ppm to 4000ppm, sulfur dioxide mixture concentrations from 3ppm to 5000pm, to be filled by NIST). Cylinders to be shipped with a blanket of nitrogen @ 30 psig.

2. A maximum of Fifty (50) new, empty Non- SGS Luxfer compressed gas aluminum cylinders (size 30 cu-ft) with ¾” tapered threat and new Ceodeux packless CGA 660 stainless steel valves.

Cylinders to be prepped and passivated by vendor to ensure stability of gas mixtures containing Nitric oxide / sulfur dioxide in nitrogen balance. (Nitric oxide mixture concentrations from 0.7ppm to 4000ppm, sulfur dioxide mixture concentrations from 3ppm to 5000pm, to be filled by NIST). Cylinders to be shipped with a blanket of nitrogen @ 30 psig

V. DELIVERABLES

Description Quantity Due Date

Non- SGS Luxfer aluminum compressed gas cylinders with packless CGA-350 brass valves.

Eighty (80) empty (size 30 cu-ft)

Within 120 days of award to the

Subject Matter Expert (SME)

Separately Priced Line Item:

SGS Luxfer compressed gas aluminum cylinders with ¾” tapered thread and new Ceodeux packless CGA 660 stainless steel values

Maximum of Fifty (50) empty (size 30 cu-ft)

Within 120 days of award to SME

Separately Priced Line Item:

Non -SGS Luxfer compressed gas aluminum cylinders with ¾” tapered thread and new Ceodeux packless CGA 660 stainless steel valves.

Maximum of Fifty (50) empty (size 30 cu-ft)

Within 120 days of award to the

SME

Factory Acceptance Test Report

Emailed for review and acceptance to the SME prior to shipment to

NIST.

VI. TESTING & ACCEPTANCE

The Contractor shall provide a factory acceptance test report to the NIST SME for review and acceptance. The Contractor shall not ship cylinders to NIST until after receipt of written acceptance from the NIST SME of the factory acceptance test report. The NIST SME will provide a response to the Contractor within two weeks of receipt.

The factory acceptance test report shall provide a description of the passivation process and the gas mixture pre-loaded in the cylinders for shipping. The factory acceptance test shall indicate, for each cylinder number, the leak test acceptance criteria and the leak test result (may be pass/non-pass or a numerical result).

VII. WARRANTY

GSMG will conduct another leak test on the cylinders within a year of delivery. The Contractor shall replace any leaking cylinder within 30 days at the Contractors expense, excluding shipping fees.