Spec_Sheet_-_Odyssey_Battery_ODX-AGM31.pdf

PDF 160 KB Posted

Attached to
Traffic UPS, Batteries, Traffic & Solar Flashers
Solicitation number
24-0161-ITB
Issued by
Pinellas County, Florida

About this file

This specification sheet details the Odyssey ODX-AGM31 battery manufactured by EnerSys, a product included in Pinellas County, Florida's Invitation to Bid #24-0161-ITB for Uninterruptible Power Source (UPS) Batteries, Traffic & Solar Flashers. The solicitation seeks 480 units of the Odyssey ODX-AGM31 battery to replace non-functioning batteries in Myer UPS traffic controller cabinets and ITS cabinets, with proposals due March 28, 2024, at 3:00 pm and vendor questions accepted until March 21, 2024. The initial contract term is 12 months with potential for four additional 12-month renewals. Deliveries will be accepted Monday through Thursday from 8:00 am to 5:00 pm at 22211 U.S. Highway 19 North, Building 1, Clearwater, Florida. The Odyssey ODX-AGM31 is an AGM technology battery designed for extreme outdoor temperature applications, operating across -40 to 60 degrees Celsius, with virgin lead-alloy grids and a 4-5 year manufacturer warranty. The battery can be mounted or stored in any orientation except inverted and maintains a 2-year storage life at 68 degrees Fahrenheit without requiring recharge.

Vendors must provide transportation and delivery with no additional fees, and batteries must be date stamped upon installation with unconditional free replacement for battery failures. The total expenditure cap for this procurement is $1,825,000.00, which covers the procurement of three battery types across 700 total units (Alphacell 100XTV at 100 units, Odyssey ODX-AGM31 at 480 units, and Bright Way BW 12550 DC at 120 units). The contract allows for potential multiple contractor awards to fulfill material and delivery demands, with no specific set-aside designations for disadvantaged enterprises mentioned in the documentation. Vendors must provide comprehensive technical specifications, including runtime tables, discharge characteristics, and performance metrics across various environmental conditions.

View the file

Other files

Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EnerSys World Headquarters 2366 Bernville Road Reading, PA 19605, USA Tel: +1-800-964-2837

EnerSys EMEA EH Europe GmbH Baarerstrasse 18 6300 Zug, Switzerland

EnerSys Asia 152 Beach Road #11-08 Gateway East Building Singapore 189721 Tel: +65 6416 4800

Want more info?

Scan code to access the ODYSSEY® Battery Literature Library

© 2022 EnerSys. All rights reserved. Trademarks and logos are the property of EnerSys and its affiliates unless otherwise noted. Subject to revisions without prior notice. E.&O.E.

Date Downloaded: February 16, 2022 www.odysseybattery.com www.enersys.com

PDF Generated at https://www.odysseybattery.com 02/16/2022 18:28:39 Information correct at time of exporting PDF. Please check website for updates.

Drawings & Terminal Position

Handling and Storage Can be mounted or stored in any orientation except inverted 2-years storage life at 68°F (20°C) without needing to charge. Recharge when the OCV is <12.6V (50% SOC).

Classified as non-spillable and approved as non-hazardous cargo for ground, sea and air transportation in accordance with the requirements of IMDG (International Maritime code for Dangerous Goods) and ICAO (International Civil Aviation Organisation)

Charging and Self-Discharge Type of charging curve IUU

Charger voltage at 68°F (20°C) 14.4V to 14.8V

Self-discharge per month at 68°F (20°C) 1.25%

Self-discharge per month at 104°F (40°C) 5%

80% depth of discharge cycles 400

Technical Data Sheet

ODX-AGM31

(31-PC2150S)

Battery Type Group 31 with SS 3/8 inch threaded stud terminals and single external vent Absorbed Glass Mat (AGM) with Thin Plate Pure Lead (TPPL) Advanced dual purpose battery for engine start and deep cycle use

Power and Performance Voltage 12V

Pulse (5 second) Hot Cranking Amps

(PHCA)

2150A

Cold Cranking Amps (CCA) 1150A

HCA 1545A

MCA 1370A

20Hr Nominal Capacity (Ah) 100Ah

10Hr Nominal Capacity (Ah) 92Ah

Reserve Capacity Minutes 205 mins

Terminal 3/8-16" Stud

Torque Spec in-lbs (Nm max) 200 (22.6) studs only

Internal Resistance (mΩ) 2.2 mΩ

Short Circuit (A) 5000A

Dimensions and Weight Length 13 in / 330 mm

Width 6.8 in / 173 mm

Height (terminals included) 9.5 in / 241 mm

Height (container) 8.5 in / 216 mm

Weight 77.8 lbs / 35.3 kg

Temperature Operating temperature range -40°F / -40°C to 176°F / +80°C

Optimum storage temperature 68°F / +20°C

Accreditations The management systems governing the manufacture of this product are ISO 9001 and ISO 14001 certified.

*Cold Start Performance S.A.E J537 Apr 2016