About this file
This document is a detailed product specification sheet for the Bright Way Group (BWG) BW 12550 DC (12V55Ah) battery, associated with a Pinellas County, Florida contract opportunity for Traffic UPS, Batteries, Traffic & Solar Flashers. The specification sheet provides comprehensive technical details for a 12-volt sealed lead-acid battery designed for various applications, with a 55 Ah 20-hour capacity, dimensions of 229±2mm x 138±2mm x 211±2mm, and an approximate weight of 15.5 kg.
The battery features a 10-year designed floating life, operating temperatures ranging from -15°C to 50°C for discharge, and specific charging characteristics including float charging voltage of 13.50 to 13.80V and cyclic charging voltage of 14.50 to 15.00V. The specification sheet includes detailed technical graphs and tables covering discharge characteristics, constant current and power discharge performance, charging characteristics, cycle life, temperature effects, and self-discharge rates. The battery is constructed with lead dioxide positive plates, lead negative plates, ABS container and cover, AGM separator, and a copper terminal, making it suitable for municipal traffic and infrastructure applications.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
469.248.0380 | batterysales@bwgllc.com
POWERING PERFORMANCE
BW 12550 DC (12V55Ah)
SPECIFICATIONS
DIMENSIONS
TERMINAL
CONSTRUCTION
Component Positive plate Negative plate Container Cover Separator Electrolyte Safety valve Terminal
Raw material Lead dioxide Lead ABS ABS AGM Sulfuric acid Rubber Copper
CONSTANT CURRENT DISCHARGE CHARACTERISTICS (A, 25℃)
F.V/TIME 10min 15min 30min 60min 2h 3h 4h 5h 8h 10h 20h 9.60V 109 84.0 50.3 30.9 18.3 13.0 10.5 8.98 6.17 5.09 2.70 9.90V 106 82.0 49.2 30.4 18.2 12.9 10.4 8.92 6.13 5.08 2.69 10.2V 101 79.0 47.7 29.7 18.0 12.8 10.4 8.86 6.09 5.07 2.68 10.5V 97.0 76.3 46.6 29.0 17.7 12.8 10.3 8.80 6.05 5.04 2.67 10.8V 91.6 72.2 44.9 28.1 17.3 12.4 9.99 8.54 5.87 5.00 2.65
Nominal Voltage 12 V
Capacity (25℃)
20HR 55 Ah 5HR 44 Ah 1HR 30.5 Ah
Dimension
Length 229±2mm (9.02inch)
Width 138±2mm (5.43inch)
Height 211±2mm (8.31inch)
Total Height 214±2mm (8.43inch)
Approx. Weight 15.5kg (34.2lbs)±4% Terminal type Z (Pic) or M6
Internal resistance (Fully charged, 25℃) Approx. 7.5mΩ
Capacity affected by temperature
(10HR)
40℃ 102% 25℃ 100% 0℃ 85%
-15℃ 65%
Self-discharge (25℃)
3 month Remaining Capacity: 91% 6 month Remaining Capacity: 82%
12 month Remaining Capacity: 65% Nominal operating temperature 25℃±3℃(77℉±5℉)
Operating temperature range
Discharge -15℃~50℃(5℉~122℉) Charge -10℃~50℃(14℉~122℉) Storage -20℃~50℃(-4℉~122℉)
Float charging voltage(25℃)
13.50 to 13.80V Temperature compensation:
-18mV/℃
Cyclic charging voltage(25℃)
14.50 to 15.00V Temperature compensation:
-30mV/℃
Maximum charging current 15A Maximum discharge current 500 A(5 sec.)
Designed floating life(20℃) 10 years
469.248.0380 | batterysales@bwgllc.com
POWERING PERFORMANCE
CONSTANT POWER DISCHARGE CHARACTERISTICS (WATT, 25℃)
F.V/TIME 10min 15min 30min 60min 2h 3h 4h 5h 8h 10h 20h 9.60V 1177 922 564 352 212 153 124 106 73.3 60.8 32.4 9.90V 1142 900 553 347 210 152 123 105 72.9 60.7 32.3 10.2V 1095 867 536 338 208 151 122 105 72.4 60.5 32.2 10.5V 1048 837 523 331 205 150 121 104 71.9 60.1 32.0 10.8V 989 793 503 321 200 145 117 101 69.7 59.7 31.8
Note: The above characteristics data can be obtained within three charge/discharge cycles.
Discharge Characteristics (25℃)
The Relationship for Open Circuit Voltage and Residual Capacity (25℃)
Floating Life on Temperature
Effect of Temperature on Capacity
Charging Characteristics (25℃)
The Relationship for Charging Voltage and Temperature
Cycle Life on D.O.D (25℃)
Self-discharge Characteristics
Charged Volume
Charge Voltage
Charging Current discharge% Depth of 30