SPEC REVISED 15 Apr 26.pdf

PDF 54 KB Posted

Attached to
Purchase of Two (2) each Ground Power System (GPU)
Solicitation number
FA520926Q0022
Issued by

About this file

This is a specification document for a federal contract opportunity (FA520926Q0022) issued by the U.S. Army for the purchase of two Ground Power Systems (GPUs) to be delivered to USARJ, Camp Zama, Kanagawa, Japan within 200 days after receipt of order.

The specification requires static frequency converter units with a minimum 45KVA solid-state power rating, recommended model UFC-45M manufactured by Unitron or an equal alternative. Output requirements include 115/200V AC at 130 maximum amperes at 400Hz with minimum 45KVA capacity, plus 28.5VDC minimum 600A peak with minimum 2000A capability. Input power must be 208V to 240V. Physical dimensions are constrained to a maximum of 2000mm length, 1000mm width, and 1350mm height, with a maximum weight of 1000 lbs including mobile equipment. Each GPU must be mounted on a towable push cart or trailer with a towbar (3 or 4 wheels) and include 2 steering bars. Required accessories include a minimum 10-meter input cable rated for 480VAC and a minimum 15-meter output cable with AC 3-phase 400Hz connectors. The units must be compatible with UH-60L, AH-64, and HH-60 aircraft; include military interlock capability; and comply with ISO 6858, MIL-STD-704F, and DFS-400 standards. The contractor must provide 2 operating manuals and 2 maintenance/repair manuals in English, on-site setup and training at Camp Zama, on-site troubleshooting support by a certified technician during the warranty period, and a minimum one-year warranty or 3000 hours covering parts and labor. Additional requirements include auto calibration capability to compensate for voltage drop, software update capability, neutral voltage and leakage current monitoring, and overload rating up to 400% for one second.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FA520926Q0022

Attachment 1

SPECIFICATION

Purchase of Two (2) each Ground Power System (GPU)

Salient Characteristic of Static Frequency Convertor Recommend UFC-45M (Manufactured by Unitron) or Equal Power Rating Minimum 45KVA Solid State

Output AC: 115/200V, 130 Max AMPS, 400Hz, Minimum 45KVA DC: 28.5VDC Minimum 600A Peak Minimum 2000A

Input Input power must be 208V to 240V Overall Length Max 2000mm Overall Width Max 1000mm Overall Height Max 1350mm

Weight Max 1000 lbs including mobile Towable Type Push Cart or Trailer with Towbar (3 or 4 wheels) Steering bar 2 each

Military Interlock Required Input Cable Minimum 10m and 480 VAC

Output Cable Minimum 15m and AC 3phase 400Hz output plug has 6 x holes, A-phase, B-phase, C-phase, N-phase and E & F DC signal holes. Military interlock is for E&F DC signal

Input Plug P/N: Hubbel HBL4200PS2W, 200 amp, 3W, 4P, or similar

Compliant with ISO 6858, MIL-STD-704F, DFS-400

Miscellaneous Aircraft Compatibility Compatible with UH-60L’s AH-64’s, HH-60’s

Operating Manual 2 ea English Maintenance and Repair Manuals 2 ea English

Delivery Within 200 Days ARO

Warranty Minimum one year or 3000 hours: covers on-site troubleshooting parts, and labor during the warranty period

On site Set-up and Training Training will include on site instruction on the use of the GPU on-site, Camp Zama, Kanagawa, Japan

On Site Troubleshooting Provide on-site support by a certified technician during the warranty period

Internal Calibration Auto Calibration, able to compensate for voltage drop in distribution cables. Auto calibration of each phase

Software Based Able to receive software updates Monitoring Neutral voltage and leakage current monitoring

Overload Rating Up to 400% for one second Delivery Point USARJ, Camp Zama, Kanagawa, Japan

File details come from the government source that posted it. Updated .