Spec 024100 - Demolition.doc
DOC document 31 KB Posted
- Solicitation number
- 36C26125Q0481
About this file
The document is a technical specification (Spec 024100) for demolition services, specifically detailing requirements for demolition and removal of buildings, utilities, and debris at a medical center site. The specification outlines comprehensive safety and protection protocols, including preventing hazards to personnel, minimizing interference with adjacent areas, and maintaining site safety through measures such as warning signs, barricades, and temporary fences. Key execution requirements include daily debris removal off-site, breaking up concrete slabs below grade, legally disposing of materials in compliance with federal, state, and local regulations, and removing existing utilities in a manner conforming to national codes. The specification emphasizes contractor responsibilities for site survey, avoiding damage to existing structures, and coordinating demolition work with other project activities, with all work subject to approval by the Resident Engineer.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Spec 072200 - Roof And Deck Insulation.doc | DOC document | |
| Sepc 075423 Thermoplastic Polyolefin TPO Roofing.docx | DOCX document | |
| 662-25-111 SOW EPDM Roofing Replacement in BLDG 5.docx | DOCX document | |
| Spec 071200 - Built-up Bituminous Waterproofing.doc | DOC document | |
| Spec 07510 - roofing.doc | DOC document | |
| P02 - SSN - 36C26125Q0481.docx | DOCX document | |
| Spec 07920 - sealing caulking.doc | DOC document | |
| 010000_MASTER.doc | DOC document | |
| Spec 07600 - flashing.doc | DOC document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
11-08M
SECTION 02 41 00
PART 1 ‑ GENERAL
1.1 DESCRIPTION:
This section specifies demolition and removal of buildings, portions of buildings, utilities, other structures and debris from trash dumps shown.
1.2 RELATED WORK:
A.
Safety Requirements: GENERAL CONDITIONS Article, ACCIDENT PREVENTION.
B.
Disconnecting utility services prior to demolition: Section 01 00 00, GENERAL REQUIREMENTS.
C.
Reserved items that are to remain the property of the Government: Section 01 00 00, GENERAL REQUIREMENTS.
1.3 PROTECTION:
A.
Perform demolition in such manner as to eliminate hazards to persons and property; to minimize interference with use of adjacent areas, utilities and structures or interruption of use of such utilities; and to provide free passage to and from such adjacent areas of structures. Comply with requirements of GENERAL CONDITIONS Article, ACCIDENT PREVENTION.
B.
Provide safeguards, including warning signs, barricades, temporary fences, warning lights, and other similar items that are required for protection of all personnel during demolition and removal operations. Comply with requirements of Section 01 00 00, GENERAL REQUIREMENTS, Article 1.9 PROTECTION OF EXISTING VEGETATION, STRUCTURES, EQUIPMENT, UTILITIES AND IMPROVEMENTS.
C.
Maintain fences, barricades, lights, and other similar items around exposed excavations until such excavations have been completely filled.
D.
Prevent spread of flying particles and dust. Sprinkle rubbish and debris with water to keep dust to a minimum. Do not use water if it results in hazardous or objectionable condition such as, but not limited to; ice, flooding, or pollution. Vacuum and dust the work area daily.
F.
In addition to previously listed fire and safety rules to be observed in performance of work, include following:
1.
No wall or part of wall shall be permitted to fall outwardly from structures.
3.
Wherever a cutting torch or other equipment that might cause a fire is used, provide and maintain fire extinguishers nearby ready for immediate use. Instruct all possible users in use of fire extinguishers.
4.
Keep hydrants clear and accessible at all times. Prohibit debris from accumulating within a radius of 4500 mm (15 feet) of fire hydrants.
G.
Before beginning any demolition work, the Contractor shall survey the site and examine the drawings and specifications to determine the extent of the work. The contractor shall take necessary precautions to avoid damages to existing items to remain in place, to be reused, or to remain the property of the Medical Center; any damaged items shall be repaired or replaced as approved by the Resident Engineer. The Contractor shall coordinate the work of this section with all other work and shall construct and maintain shoring, bracing, and supports as required. The Contractor shall ensure that structural elements are not overloaded and shall be responsible for increasing structural supports or adding new supports as may be required as a result of any cutting, removal, or demolition work performed under this contract. Do not overload structural elements. Provide new supports and reinforcement for existing construction weakened by demolition or removal works. Repairs, reinforcement, or structural replacement must have Resident Engineer’s approval.
1.4 UTILITY SERVICES:
N/A PART 2 - PRODUCTS (Not Used)
PART 3 – EXECUTION
3.1 DEMOLITION:
A.
Debris, including brick, concrete, stone, metals and similar materials shall become property of Contractor and shall be disposed of by him daily, off the Medical Center to avoid accumulation at the demolition site. Materials that cannot be removed daily shall be stored in areas specified by the Resident Engineer. Break up concrete slabs below grade that do not require removal from present location into pieces not exceeding 600 mm (24 inches) square to permit drainage. Contractor shall dispose debris in compliance with applicable federal, state or local permits, rules and/or regulations.
B.
Remove and legally dispose of all materials, other than earth to remain as part of project work, from any trash dumps shown. Materials removed shall become property of contractor and shall be disposed of in compliance with applicable federal, state or local permits, rules and/or regulations. All materials in the indicated trash dump areas, including above surrounding grade and extending to a depth of 1500mm (5feet) below surrounding grade, shall be included as part of the lump sum compensation for the work of this section. Materials that are located beneath the surface of the surrounding ground more than 1500 mm (5 feet), or materials that are discovered to be hazardous, shall be handled as unforeseen. The removal of hazardous material shall be referred to Hazardous Materials specifications.
C.
Remove existing utilities as indicated or uncovered by work and terminate in a manner conforming to the nationally recognized code covering the specific utility and approved by the Resident Engineer. When Utility lines are encountered that are not indicated on the drawings, the Resident Engineer shall be notified prior to further work in that area.
3.2 CLEAN‑UP:
On completion of work of this section and after removal of all debris, leave site in clean condition satisfactory to Resident Engineer. Clean‑up shall include off the Medical Center disposal of all items and materials not required to remain property of the Government as well as all debris and rubbish resulting from demolition operations.
‑ ‑ ‑ E N D ‑ ‑ ‑