CIRCUIT BREAKER TechSpecsSOW.pdf

PDF 45 KB Posted

Attached to
Smart High Primary Injection Test System
Solicitation number
SP4706-24-Q-0039
Issued by

About this file

This document is a technical specification for a Smart High Current Primary Injection Test System required by the Defense Logistics Agency (DLA) for the DLA Product Test Center in Columbus, Ohio.

The key requirements are for a new, not refurbished, test system that can output up to 2,000A (expandable to 7,478A with 4 units in parallel), has multiple adjustable output ranges, advanced metering and timing capabilities, communication ports, automated testing software, and the ability to test low-voltage molded-case circuit breakers up to 225A. The system must include a smart touch interface, protective devices, software for report generation and record keeping, and a 24-month warranty. The system is to be delivered within 10 weeks to the specified location in Columbus, Ohio. Invoicing will be through the Wide Area Workflow system. The government points of contact are also provided.

View the file

Other files

File Type Posted
AMENDED_SF1449_SP470624Q0039.pdf PDF
SF_1449SP470624Q0039.pdf PDF
Tech Specs CIRCUIT BREAKER TESTER.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Rev 06/26/2024

Technical Specifications

Smart High Primary Injection Test System

DLA Product Test Center, VTA

I. The contractor shall provide all labor, materials, tools, transportation, supplies, supervision, etc. (except as noted), necessary to provide all components for a Smart High Current Primary Injection Test System used to test low-voltage molded-case circuit breakers up to a rating of 225A to the Defense Supply Center Columbus

(DSCC), Columbus, Ohio. The salient characteristics of the Smart High Current Primary Injection Test System are as listed below:

A. Smart High Current Primary Injection Test System with support equipment and with the following salient characteristics:

1. Shall be new, not refurbished.

2. Shall be supplied with Operating manual.

3. Shall be powered by standard US 115V, 15A AC power outlet.

4. Shall be able to output up to 2,000A and be expendable to 7478A if running 4 units in parallel.

5. Shall have three continuously adjustable output ranges: 25 to 500A at 3.5 V MAX, 6.25 to 125A at

14V MAX and 1.25 to 25A at 70V MAX.

6. Shall have a 5-digit auto ranging ammeter display ranging from 1.0000A to 99.999 kA with an accuracy of RMS pulse +/- 1.5% of reading or +/- 0.075A.

7. Shall have a 5-digit auto ranging voltameter display ranging from 0.01 to 600.00V with an accuracy of +/- 1%.

8. Shall have a 5-digit auto ranging timer display ranging from 0.001 to 99999 seconds with an accuracy of +/- 1%.

9. Shall have two ethernet and two USB 2.0 communication ports.

10. Shall be a smart high current primary injection test system for all forms of high current testing required in a substation, including testing overcurrent relays, circuit breakers, motor overloads and current transformers.

11. Shall be Designed for switchgear commissioning, circuit breaker, CT commissioning, ground grid and relay testing

12. Shall have the ability to perform high current commissioning tests as well as test low-voltage molded-case circuit breakers up to a rating of 225A.

13. Shall have software that includes thousands of circuit breaker curve TCC curves.

14. Shall have the ability to turn on at the current zero crossing every time for any load by automatically adjusting the output firing angle.

15. Shall be able to execute automated test programs from a laptop or manually controlled from a Smart

Touch View Interface.

16. Shall include a Smart Touch View Interface that has a simplified touch screen input for manual control.

17. Shall include fuse, circuit breaker and overload protective devices to be incorporated in the system.

18. Shall be provided with software that allows for automated testing, report generation and maintenance record keeping of all primary injection and low voltage circuit breaker tests.

19. Shall have software that includes thousands of circuit breaker curve TCC curves.

20. Shall be able to all breaker parameters including: long time pick-up, long time timing, short time pick-up, short time timing, instantons pick-up, ground fault pick-up and ground fault timing.

21. Shall be able to record up to ten trip/ reclose operations with each trip current, trip time and reclose time recorded.

22. Shall have: a Certificate of Calibration and a 24 Month Extended Warranty.

DLA Product Test Center, VTA

B. Required Upgrades and Accessories - Brand Name or Equal:

1. Shall at a minimum have: Included Accessories: All necessary electrical cables, communication cables to install and operate machine.

2. Shall be provided with a Smart Touch View Interface that uses a stand ethernet cable and PoE operation, include non-volatile built-in data storge for saving tests and test results and have two USB ports for transferring test results.

3. Shall include the PowerDB Pro Licenses, SQL Upgrade, and purchases options support and maintenance for a period of one year from the date of delivery of the equipment.

C. Place of Performance

The instrument shall be delivered to:

Defense Supply Center Columbus

300 North James Road, Bldg 17-3

Mark for: DLA Product Test Center, Bldg 11-7 (TE Lab)

Attn: Jeremiah L. Jones (jeremiah.l.jones@dla.mil / 614-692-8955)

Columbus, Ohio 43213

D. Travel (if applicable)

N/A

E. Invoicing

Payment of invoices will be accomplished by payment through the Defense Finance and Accounting

Service. Invoices will be submitted to the Wide Area Workflow (WAWF) system in accordance with

DFARS 252.232-7003 Electronic Submission of Payment Requests and Receiving Reports and DFARS

252.232-7006 Wide Area Workflow Payment Instructions within 10 workdays after the conclusion of each training session.

F. WAWF Acceptance DODAAC#

1. TA Lab is SL0700.

G. Other Requirements:

1. Delivery: 10 Weeks from date of the award.

2. Contractor shall give notification to Jeremiah L. Jones (jeremiah.l.jones@dla.mil /614-692-8955) when the instrument is ready to be delivered.

3. All shipping costs are to be included in the contracted price.

4. The instrument shall be delivered to:

Defense Supply Center Columbus

300 North James Road, Bldg 17-3

Mark for: DLA Product Test Center, Bldg 11-7 (TE Lab)

Attn: Jeremiah L. Jones (jeremiah.l.jones@dla.mil / 614-692-8955)

Columbus, Ohio 43213 mailto:jeremiah.l.jones@dla.mil

DLA Product Test Center, VTA

5. Invoices shall be submitted through Wide Area Workflow (WAWF), See DFARS Clause 252.232-

7006 Wide Area Workflow Payment Instructions for detailed instructions on how to submit invoices.

H. Points of Contact

The Government Contract Officer:

TBD

The Government Contract Officer Representative (COR):

Kyle Palmer

Kyle.palmer@dla.mil

(614) 692-8860

DLA Land & Maritime Product Test Center, 3990 E. Broad St., Columbus OH, Bldg. 11, Section 7

Jacob Chevraux (614) 692-0024

The Government Technical Representative

Name: Jacob Chevraux

Phone #: (614) 692-0024

Email: Jacob.chevraux@dla.mil mailto:Kyle.palmer@dla.mil