This is a price schedule attachment listing 13 specific items of industrial hygiene equipment to be procured, including detailed specifications and quantities. The items include noise dosimeters (10 units plus cases), sound level meters (2 units), noise calibrators (3 units), indoor air quality meters (2 units), ventilation smoke tubes (2 units), portable personal air sampler pump kits (2 kits), air sampling inhalable samplers (10 units), and related accessories.
Each line item includes specific technical requirements, acceptable manufacturer models (typically offering two options), required certifications/standards compliance, and delivery quantities. All items are to be shipped to Ft. Belvoir, VA with Laura Cox or MAJ Derek Monthei listed as points of contact. The schedule is structured with Contract Line Item Numbers (CLINs) 0001-0013, with fields for unit price and total amount to be filled in by bidders. No pricing information is provided in this version of the schedule.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 2 – Price Schedule
Page | 1
Contract Line Item Number
(CLIN)
Item Item Specifications Make and Models Item Requirements
Unit of Issue
Quantity Unit Price $
Total Amount $
Ship to POC Address
0001 Noise Dosimeter(s)
Single-unit Dosimeter with
✓ Microphone A-weighted Dynamic Range 94 dB Peak Range 78 – 143 dB Peak, C-weighted Peak Weightings A, C, Z RMS Weightings A, C, Z Time Weightings Slow, Fast, Impulse Frequency Range 20 Hz to 10 kHz Data
✓ Windscreen;
✓ USB Cable;
✓ Power Cord;
✓ Calibration Adapter;
✓ Unit Carry Case
✓ 2-year warranty
TSI® Edge 7 Single Dosimeter
EG7
Or
Larson Davis MODEL Spartan
Standards ANSI S1.25-1991 (R2017), IEC 61252 Ed. 1.2 Linear Operating Range 52 – 140 dB rms Logging Selectable 1 second- or 1-minute samples Logged data LAeq, LCeq, LCpeak, LZpeak, LASmax, LAFmax, ACGIH TWA 3 dB Exchange, OSHA TWA 5dB Exchange
Each
(EA)
Two (2) sets of 5 plus two carry cases
Laura Cox/ or MAJ Derek Monthei 8725 John J.
Kingman Ft. Belvoir, VA 22060
0002 Sound Level Meter (SLM)
Type II Sound Level Meter (SLM) with:
✓ Exchange rates of 3,4,5,6 dB
✓ TWA, Lavg, Lmax Lpeak Impluse, Dose
✓ 1/1 and 1/3 Octave 40 to 140 dB
✓ Calibrator adapter
TSI ® Sound Pro
SE DL
SP-SE-2-1/3
Or
Larson Davis® Spartan Series 821H
ANSI S1.4-1985
(R2001), S1.43- 1997 (R2002 /S1.25-1991 (R2007), S1.11-
ANSI A10.46-2007
Each
(EA)
2 Laura Cox/ or MAJ Derek Monthei
8725 John J.
Kingman Ft. Belvoir, VA 22060
Page | 2
0003 Noise Calibrator Calibrator adapter for 1/4 inch microphone Output: 114 dB, 1000 Hz, portable self-contained field calibrator
Larson Davis
CAL150
or
TSI AC3 or equivalent
ANSI S1.40
Each
(EA)
Monthei
8725 John J.
Kingman Ft. Belvoir, VA 22060
0004 Indoor Air Quality (IAQ) Meter
Single unit that measures:
✓ 6 different types of gases,
✓ PM2.5 and PM10 mass concentrations and particle counts:
✓ Temperature:
✓ Relative humidity:
and barometric pressure
✓ Portable Stand
TSI Q-Trak XP IAQ monitor model
EVM-7
Or equivalent
Quest EVM-7
SENSORS:
✓ Carbon Dioxide sensor (0-5000 ppm)
✓ Carbon Monoxide Sensor (0-50 ppm)
✓ Nitrogen Dioxide sensor
✓ Nitrogen Oxide Sensors
✓ Hydrogen sulfide sensor
✓ TVOC sensor – Low
✓ TVOC sensor -high
Each
(EA)
2 Laura Cox 8725 John J.
Kingman
Page | 3
0005 Portable personal air sampler pumps kit
A kit of five (5) Personal air samplers
✓ Flow Range meets Constant flow 20 – 5,100 cc/min. without external adaptors Constant pressure 1 – 5,100 cc/min without external adaptors
✓ Constant Flow or High and Low Flow Constant Pressure
✓ Run Time 8-hour minimum
✓ Temperature Ranges Operating 32°F to 113°F (0°C to 45°C) Storage -4°F to 113°F (- 20°C to 45°C) Charging 41°F to 104°F (5°C to 40°C)
✓ Humidity Ranges Operating 5-95 %RH, non-condensing Storage 5-98 %RH, non-condensing
✓ Display Flow rate, sample time, and sample volume in actual conditions
✓ Controls Indicators Green and Red LED’s
✓ Dimensions no more than
4.3 x 2.4 x 2.4 inches (10.9
GilAir Plus Sampling Pump
910-0904-US-R
or
SKC AirChek Essential 5-pack High/Low Flow Pump Kit
ISO 13137:2013
Compliant
Intrinsic Safety US/Canada NRTL
(FM):
Class I, Div 1 Groups A, B, C, D, E, F, and G; Class II, Div 1 Zone 0; Class
III, T4
ATEX/IEC:
Ex – II 1 G; Ex ia IIC T4
CE
Applicable Directives:
ATEX 94/9/EC;
EMC 2004/108/EC
(RFI); LVD
2006/95/EC; RoHS Compliant
Each
2 Laura Cox/ or MAJ Derek Monthei
8725 John J.
Kingman
Page | 4 x 6.1 x 6.1 centimeters) Weight 20.5 ounce (581 grams)
✓ Warranty must be 2 years from original shipment
✓ Rechargeable nickel-metal hydride (NiMH) battery pack, or optional alkaline battery pack, or DC power.
✓ Battery Level Indicator On-screen icon displays battery level.
✓ Charging Time less than 3.5 hours.
✓ Tygon tubing 1/inch
0006 Primary Calibrator, low, standard and high volume
Primary Standard (NIOSH) Dry Cell Calibrator –with Stable Back Pressure with
(3) dry flow cells for:
✓ Low: 5-450 cc/min,
✓ Standard: 50-5000 cc/min,
✓ High: 1 LPM-30 LPM)
Gilian® Gilibrator®
910-1701-US-R
Or
Bios Drycell Defender
ISO 13137:2013
Compliant
Intrinsic Safety US/Canada NRTL
(FM):
Class I, Div 1 Groups A, B, C, D, E, F, and G; Class II, Div 1 Zone 0; Class
III, T4
Each
(EA)
2 Laura Cox/ or MAJ Derek Monthei
8725 John J.
Kingman
Page | 5
0007 Micromanomete r
Micromanometer Unit that measures
✓ Pressure, velocity and flow o
✓ Auto-zeroing pressure sensor
✓ Automatic density correction
✓ Duct traverse
✓ Pitot, air flow (straight pitot), Temperature /relative humidity, velocity matrix, or thermoanemometer probes
TSI EBT 730 Alnor Micromanometer
EBT 730
Or equivalent
NIST-traceable calibration certificate
Each
(EA)
1 Laura Cox/ or MAJ Derek Monthei
8725 John J.
Kingman Ft. Belvoir, VA 22060
0008 Light meter Light meter measures
✓ Fluorescent
✓ Halogen Lamps
✓ Incandescent
✓ LED
✓ Metal Halide
✓ Sodium
✓ Up to 99,990 footcandles
9.999 fc ±3%
0.001 fc
✓ 36 in Coiled Cable
✓ Built-In Stand
✓ Carrying Case
✓ Light Sensor
✓ Protective Cover Protective Holster
Extech
EA-30
Or equivalent
Each
Monthei
8725 John J.
Kingman
Page | 6
0009 Ventilation Smoke tubes
Tube Kits Allows for controlled generation of visible smoke Determines velocity and flow patterns of heating, ventilating and air-conditioning systems Available with glass or plastic tubes with break-off tips
MSA™ Ventilation Smoke 458481
NA Each
(EA)
2 Laura Cox/ or MAJ Derek Monthei
8725 John J.
Kingman
Page | 7
0010 Handheld Articulating Video boroscope with minimum of 5” monitor display
Articulation video boroscope
✓ Minimum 5 inch color monitor screen
✓ Diameter of probe Less 6 mm
✓ Articulating
✓ 4-way/joystick, manual
✓ Min 1.5 meter probe length
✓ 3 meter probe length
✓ Full Manufacturer warranty
Less than weight: 2 lbs.
Power supply
Power supply/ rechargeable or and battery
Battery operating time: 4 h (battery status in display)
General Electric XL Flex
Or
Or equivalent –
Operating temperature: 32 – 104 °F
Protection:
Waterproof to IP 67 (up to 40 ft.
depth for 30 mins.)
Power supply: 3.7 V rechargeable battery
Operating temperature: 0 – 104 degrees F
Each
(EA)
1 Laura Cox/ or MAJ Derek Monthei
8725 John J.
Kingman Ft. Belvoir, VA 22060
0011 Air Sampling tubing
Tygon Tubing, 1/4-inch ID x 3/8-inch OD, 10 feet Overview
200484 Each
(EA)
2 Laura Cox/ or MAJ Derek Monthei 8725 John J.
Kingman
Page | 8
0012 Low flow sampling tubing kit
Low Flow Adapter Kit, 5 to 500 ml/min Overview
Each
(EA)
5 Laura Cox/ or MAJ Derek Monthei 8725 John J.
Kingman Ft. Belvoir, VA 22060
0013 Air sampling inhalable samplers
IOM Inhalable Samplers and Cassettes, Plastic Overview
385-0095-01 Each
(EA)
10 MAJ Derek Monthei Laura Cox/ or 8725 John J.
Kingman Ft. Belvoir, VA
TOTAL
File details come from the government source that posted it. Updated .