COLUMBUS

AND VlaNITY

UPPER ARLINGTON

LANE. A'£.

W. BRO"° ST.

GROVE CITY

VI/ORK LCJCA.T!(J1�

WESTERVILLE

MORSE RD.

oem

RICKENBACKER AFB

VICINITY MAP

GRANVllil 'fttl.

GROVEPORT

® LOCATION MAP

BRICE

40'\=====

REYNDLDSBURG

70)=====

WINCHESTER

DEFENSE� SUPPLY CENTER

COLUMBUS

PROJECT NUMBER CSC�19300

BU LO NG 308 MPROVEMENTS

INDEX OF DRAWINGS

SHEET NO. SHEET TITLE SHEET NO.

G-OO1 COVER SHEET

G-OO2 GENERAL NOTES

A-1O1 EXISTING CONDITIONS

A-1O2 DEMO PLAN - AREA 1

A-1O3 DEMO PLAN - AREA 2

A-1O4 DEMO PLAN - RESTROOMS & BREAKROOM

A-1O5 NEW WORK - AREA 1

A-1O6 NEW WORK - AREA 2

A-1O7 NEW WORK - RESTROOMS

A-1O8 NEW WORK - BREAKROOM

A-1O9 REFLECTED CEILING PLAN

A-11O PROPOSED FURNITURE PLAN

A-111 DOOR SCHEDULE

A-112 \11/INDOW SCHEDULE

A-113 INTERIOR FINISH & SIGNAGE SCHEDULE

A-5O1 DETAILS - BREAKROOM

A-5O2 DETAILS - BATHROOM COUNTERTOPS

M-OO1 MECHANICAL GENERAL NOTES

M-1O1 HVAC DEMO - AREA 1

M-1O2 HVAC DEMO - AREA 2

M-1O3 HVAC DEMO - AREA 3

M-1O4 HVAC DEMO - AREA 4

M-1O5 WEST OFFICE NEW HVAC WORK AHU-1 SUPPLY DUCT

M-1O6 WEST OFFICE NEW HVAC WORK AHU-1 RETURN DUCT

M-1O7 WEST OFFICE NEW HVAC WORK DOAS-1 OUTSIDE AIR DUCT

M-1O8 WEST OFFICE NEW HVAC WORK DOAS-1 EXHAUST DUCT

GENERAL NOTES;

1. IT SHALL BE THE CONTRACTOR'S SOLE RESPONSIBILITY TO FIELD VERIFY THE EXACT EXTENT OF

WORK, WORKING CONDITIONS AND CONSTRAINTS, PRIOR TO BIDDING.

2. DIMENSIONS SHOWN ON THE DRAWING SHALL BE VERIFIED IN THE FIELD. THE CONTRACTING

M-1O9 M-11O M-111 M-112 M-113 M-5O1 M-5O2 M-6O1 M-6O2 M-6O3 M-6O4 M-6O5 M-6O6 M-6O7 M-6O8 M-6O9 M-61O M-611

ED-1O1

ED-1O2

E-1O1 E-1O2 E-1O3 E-6O1 E-6O2

OFFICER MUST BE NOTIFIED OF ANY DISCREPANCIES PRIOR TO BIDDING AND PROCEEDING WITH THE WORK.

3. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE CONTRACTING OFFICER, THE

SCHEDULE OF WORK.

4. ANY DAMAGE DONE TO GOVERNMENT PROPERTY DURING WORK/CONSTRUCTION SHALL BE REPAIRED IN

KIND AND APPROVED/ACCEPTED BY THE GOVERNMENT.

5. ALL ADDITIONAL WORK PERFORMED BEYOND THE REQUIRED BASE CONTRACT, PRIOR TO THE APPROVAL

OF THE CONTRACTING OFFICER, WILL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.

6. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE TEMPORARY STRUCTURES AND OTHER

PROTECTIVE DEVICES NECESSARY FOR THE EXECUTION OF THE WORK.

7. CONTRACTOR SHALL FOLLOW ALL APPLICABLE SAFETY CODES.

8. ALL DEMOLITION AND DEBRIS SHALL BE HAULED AWAY FROM THE SITE DAILY.

SHEET TITLE

EAST OFFICE NEW HVAC WORK

NEW HVAC PIPING - AREA 1

NEW HVAC PIPING - AREA 2

NEW HVAC PIPING - AREA 3

NEW HVAC PIPING - AREA 4

HVAC DETAILS

HVAC DETAILS

HVAC SCHEDULES

HVAC SCHEDULES

HVAC SCHEDULES

CHILLED /HOT WATER PIPING SCHEMATIC

CHILLED WATER CONTROLS

HOT WATER CONTROLS

AHU-1 CONTROLS

DOAS-1 CONTROLS

EAST OFFICE AHU CONTROLS

VAV/CAV CONTROLS

HEATER CONTROLS

LIGHTING DEMOLITION PLAN

POWER DEMOLITION PLAN

LIGHTING PLAN

POWER PLAN

LOW VOLTAGE PLAN

ELECTRICAL SCHEDULES

ELECTRICAL DETAILS

:;..: � ;;.:co a rn 0 t:,j O � ....... w ? m 3'w " L,J 5 1° 5L,J � L,J "' " "' w w _J z --� � --�

� tr-. I='�

(.) z <( V, 0 0 w >-l.. 0 I C >- "

0 I

_J ;;;D..

ct::>= "' � CD w ..

_J >-

>' '-' 0 0 CD

£ L,J £0 CD --' >- --' w z y >- y 3'

>- ':a3' >- � <( z al z> "' L,J :::, WW 0 y V, y °'

(D 0

>- ;, (J) 0 :::, (J) z ...J

I') wOI

0 0 CXJ

<( 0::: �

(f) w I')

0 f- ..,. _z f- w

UlOO

I 0...10

...J CL

w o_ (/) z (/) (D ww::;;LL (I] :::, �z wO

LL 0

w

lf) I-z w w ci 0

Zo O:'. I- I') 0..

0 CJ)

2 w� -, I OU co O:'. (/)

CL 0 0

n z w w C, CL w " z

(f) w > S2

- LL

0 LL

I- 0

0 w 0"' D..

D..

Z c, w z CXJ :;;_a w O:'. I')

C>W <l'. w 0 zz 2 <l'. i:3- 2 z :J w-z :::, 0 (/] (D -w I- - <l'. f- ...l ...l ...J - <l'. 0 I- <l'.

(/) LL

z

I-w w I lf)

O:'.

w

SHEET

REFERENCE

NUMBER:

G-001

3-1691

AutoCAD SHX Text

SUBMITTED BY:

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR.

AutoCAD SHX Text

FACILITIES ENGINEERING OFFICE

AutoCAD SHX Text

BUILDING 308

AutoCAD SHX Text

INSTALLATION MANAGEMENT DIVISION

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

PROJECT NO.

AutoCAD SHX Text

PLOT DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

MARK

AutoCAD SHX Text DEFENSE LOGISTICS AGENCY DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990

AutoCAD SHX Text

SHEET REFERENCE NUMBER:

AutoCAD SHX Text

CUSTOMER

AutoCAD SHX Text

DF-FCE (ENVIRONMENTAL)

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

FACILITY ENGINEER

AutoCAD SHX Text

DF-FCO (SAFETY)

AutoCAD SHX Text

APPROVED BY:

AutoCAD SHX Text

DF-FCS (SECURITY)

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DEPUTY FACILITY ENGINEER

AutoCAD SHX Text 3-1691

AutoCAD SHX Text

NONE

AutoCAD SHX Text 4-Jun-19

AutoCAD SHX Text

KENT KLINGLER

AutoCAD SHX Text

ADAM DECARLO

AutoCAD SHX Text G-002

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

CSC-19300

AutoCAD SHX Text

BUILDING 308 IMPROVEMENTS

AutoCAD SHX Text

FIELD VERIFY ALL CONDITIONS

AutoCAD SHX Text DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE GOVERNMENT PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE GOVERNMENT AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT GOVERNMENT OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT.

AutoCAD SHX Text

3. WEIGHTS FOR RECYCLED, REUSED, AND LANDFILLED MATERIALS MUST BE SUBMITTED

AutoCAD SHX Text

4. THE FOLLOWING FAR CLAUSES SHALL BE INCORPORATED AS NEEDED:

AutoCAD SHX Text

52.223-1 - BIOBASED PRODUCT CERTIFICATION

AutoCAD SHX Text

5. CONTRACTOR SHALL PROVIDE SEDIMENT CONTROL BAGS TO PROTECT ALL STORM DRAINS,

AutoCAD SHX Text

%%USAFETY AND ENVIRONMENTAL

AutoCAD SHX Text

1. CONTRACTOR SHALL RECYCLE ALL DEMOLITION DEBRIS WHEN FEASIBLE.

AutoCAD SHX Text

2. EMS MATERIALS MUST BE READ AND SIGNED FOR (FAR 52.223-19).

AutoCAD SHX Text

52.223-2 - AFFIRMATIVE PROCUREMENT OF BIOBASED PRODUCTS UNDER SERVICE AND

AutoCAD SHX Text

52.223-3 - HAZARDOUS MATERIAL IDENTIFICATION AND MATERIAL SAFETY DATA

AutoCAD SHX Text

52.223-5 - POLLUTION PREVENTION AND RIGHT-TO-KNOW INFORMATION

AutoCAD SHX Text

52.223-17 - AFFIRMATIVE PROCUREMENT OF EPA-DESIGNATED ITEMS IN SERVICE AND

AutoCAD SHX Text

52.223-20 - AEROSOLS

AutoCAD SHX Text

52.223-21 - FOAMS

AutoCAD SHX Text

52.223-22 - PUBLIC DISCLOSURE OF GREENHOUSE GAS EMISSIONS AND REDUCTION

AutoCAD SHX Text

252.223-7001 - HAZARD WARNING LABELS

AutoCAD SHX Text

252.223-7006 - PROHIBITION OF STORAGE, TREATMENT, AND DISPOSAL OF TOXIC OR

AutoCAD SHX Text

CONSTRUCTION CONTRACTS

AutoCAD SHX Text

CONSTRUCTION CONTRACTS

AutoCAD SHX Text

GOALS-REPRESENTATION

AutoCAD SHX Text

HAZARDOUS MATERIALS

AutoCAD SHX Text

CURB INLETS, AND CATCH BASINS LOCATED WITHIN 100' OF EACH CONSTRUCTION SITE

AutoCAD SHX Text

BEFORE AND DURING CONSTRUCTION. ALL SEDIMENT CONTROL BAGS SHALL BE REMOVED

AutoCAD SHX Text

BY THE CONTRACTOR ONCE CONSTRUCTION IS COMPLETE.

AutoCAD SHX Text FIRE PROTECTION SPRINKLER SYSTEM DESIGN REQUIREMENTS APPLICABLE REFERENCES: 1. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 13, "AUTOMATIC SPRINKLER SYSTEM REQUIREMENTS", 2016 EDITION 2. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 72, "NATIONAL FIRE ALARM AND SIGNALING CODE", 2016 EDITION 3. UNIFIED FACILITIES CRITERIA (UFC) 3-600-01, PROJECT SCOPE: 1. NEW WORK: NEW WORK: a. THE REQUIREMENTS FOR THIS BUILDING ARE TO RETROFIT THE EXISTING FIRE SPRINKLERS AND ASSOCIATED THE REQUIREMENTS FOR THIS BUILDING ARE TO RETROFIT THE EXISTING FIRE SPRINKLERS AND ASSOCIATED PIPING NETWORK IN THE REMODELED OFFICE AREAS. b. THE CONTRACTOR IS TO PROVIDE EXTRA SPRINKLERS, CABINETS, AND WRENCHES PER NFPA 13. THE CONTRACTOR IS TO PROVIDE EXTRA SPRINKLERS, CABINETS, AND WRENCHES PER NFPA 13. c. THE CONTRACTOR IS TO COORDINATE THE PERIOD OF CLOSURE OF THE FIRE PROTECTION SYSTEM WITH THE THE CONTRACTOR IS TO COORDINATE THE PERIOD OF CLOSURE OF THE FIRE PROTECTION SYSTEM WITH THE DSCC FIRE DEPARTMENT. DURING THE PERIOD OF CLOSURE OF THE FIRE PROTECTION SYSTEM, THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING A FIRE WATCH IF THE FIRE PROTECTION SYSTEM IS DOWN FOR LESS THAN 8 HOURS. FOR CLOSURE LONGER THAN 8 HOURS, THE CONTRACTOR SHALL COORDINATE WITH DSCC FIRE DEPARTMENT AND PROVIDE A DESIGN INDICATING EQUIVALENT LEVELS OF FIRE PROTECTION WHILE THE FIRE SUPPRESSION IS DOWN. THIS EQUIVALENCY MUST BE APPROVED BY DLA FIRE PROTECTION ENGINEER PRIOR TO THE SYSTEM BEING TAKEN OUT OF SERVICE. 2. REFERENCE THE FOLLOWING CRITERIA: REFERENCE THE FOLLOWING CRITERIA: DESIGN REQUIREMENTS: OCCUPANCY CLASSIFICATION: LIGHT HAZARD PER UFC 3-600-01 APPENDIX B-1.1 (OFFICES) SYSTEM TYPE: WET-PIPE SYSTEM FIRE HYDRANT FLOWS: CONTRACTOR IS TO PERFORM FLOW TESTS TO DETERMINE; STATIC PRESSURE, RESIDUAL PRESSURE, AND HYDRANT FLOW AT RESIDUAL PRESSURE. 3. SYSTEM SHALL BE DESIGNED AND INSTALLED PER UFC 3-600-01. ALL MATERIALS USED AND ITEMS NOT SYSTEM SHALL BE DESIGNED AND INSTALLED PER UFC 3-600-01. ALL MATERIALS USED AND ITEMS NOT OTHERWISE SHOWN SHALL BE AS ALLOWED OR AS REQUIRED IN UFC 3-600-01. NOTE: ONLY SCHEDULE 40 BLACK PIPE SHALL BE USED, SCHEDULE 10 PIPE WILL NOT BE ACCEPTED PER UFC 3-600-01 SECTION 4-2.3.2 FOR DLA. 4. WATER SERVICE TO THE WET SYSTEM SHALL BE FROM NEW SEPARATE LINES PROVIDED BY THE CONTRACTOR, WATER SERVICE TO THE WET SYSTEM SHALL BE FROM NEW SEPARATE LINES PROVIDED BY THE CONTRACTOR, THE CONTRACTOR, ORIGINATING FROM THE EXISTING MAINS. 5. WATER SERVICE LINES SHALL BE SIZED BY THE CONTRACTOR AS NECESSARY TO PROVIDE ADEQUATE WATER WATER SERVICE LINES SHALL BE SIZED BY THE CONTRACTOR AS NECESSARY TO PROVIDE ADEQUATE WATER ADEQUATE WATER FLOW AT ALL POINTS WITHIN THE SYSTEM. 6. CONTRACTOR SHALL PROVIDE HYDRAULIC CALCULATIONS FOR THE FIRST FLOOR OF BUILDING 306 WITH THE CONTRACTOR SHALL PROVIDE HYDRAULIC CALCULATIONS FOR THE FIRST FLOOR OF BUILDING 306 WITH THE NEW SPRINKLERS INCLUDED, AND SHALL PROVIDE A HYDRAULIC GRAPH FOR WATER DEMAND AND AVAILABLE WATER SUPPLY, PERFORMED BY A LICENSED FIRE PROTECTION ENGINEER OR NICET IV TECHNICIAN. 7. ALL FINAL FIRE PROTECTION DRAWINGS SHALL BE SUBMITTED FOR FINAL APPROVAL INCLUDING SPRINKLER ALL FINAL FIRE PROTECTION DRAWINGS SHALL BE SUBMITTED FOR FINAL APPROVAL INCLUDING SPRINKLER LAYOUT WITH PIPE SIZE, TYPE OF SPRINKLER, RISER DETAIL, AND HYDRAULIC CALCULATIONS THAT MEET THE WATER FLOW DEMAND. CONTRACTOR SHALL NOT INSTALL ANY SPRINKLER SYSTEM COMPONENTS UNTIL THE DRAWINGS AND CALCULATIONS ARE REVIEWED AND APPROVED BY DLA COLUMBUS FIRE AND EMERGENCY SERVICES AND DLA HQ AHJ. ONCE APPROVED, HALF SIZE DRAWINGS SHALL BE PROVIDED TO THE DLA FIRE PROTECTION ENGINEER AND DLA COLUMBUS FIRE AND EMERGENCY SERVICES. 8. SPRINKLER SYSTEM INSTALLATION SHALL BE PERFORMED BY A QUALIFIED SPRINKLER CONTRACTOR LICENSED SPRINKLER SYSTEM INSTALLATION SHALL BE PERFORMED BY A QUALIFIED SPRINKLER CONTRACTOR LICENSED TO INSTALL SPRINKLER SYSTEMS IN THE STATE OF OHIO, WITH A MINIMUM OF TWO OR MORE YEARS EXPERIENCE IN THE SPRINKLER INSTALLATION FIELD. 9. PERFORM A CERTIFIED ACCEPTANCE TEST IN ACCORDANCE WITH NFPA 25 (CURRENT EDITION). PERFORM A CERTIFIED ACCEPTANCE TEST IN ACCORDANCE WITH NFPA 25 (CURRENT EDITION). 10. PROVIDE SAFETY FACTOR OF 10% OR 10 PSI (WHICHEVER IS LARGER) AS PART OF SPRINKLER DESIGN. PROVIDE SAFETY FACTOR OF 10% OR 10 PSI (WHICHEVER IS LARGER) AS PART OF SPRINKLER DESIGN. 11. ENSURE FIRE ALARM NOTIFICATION AND MASS NOTIFICATION SYSTEMS APPLIANCES ARE INSTALLED IN ENSURE FIRE ALARM NOTIFICATION AND MASS NOTIFICATION SYSTEMS APPLIANCES ARE INSTALLED IN INSTALLED IN ACCORDANCE WITH NFPA 72 AND ACCEPTANCE TESTING IS COMPLETE. 12. ENSURE IMPACT DAMAGE PROTECTION IN ACCORDANCE WITH (IAW) NFPA 221 STANDARD FOR HIGH ENSURE IMPACT DAMAGE PROTECTION IN ACCORDANCE WITH (IAW) NFPA 221 STANDARD FOR HIGH CHALLENGE FIRE WALLS, FIRE WALLS, AND FIRE BARRIER WALLS (CURRENT EDITION) 4.6 IMPACT DAMAGE. 13. COMPLY WITH ALL APPLICABLE SECTIONS OF UFC 3-600-01 (CURRENT EDITION) AND NFPA 241 (CURRENT COMPLY WITH ALL APPLICABLE SECTIONS OF UFC 3-600-01 (CURRENT EDITION) AND NFPA 241 (CURRENT EDITION) SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS. OPERATIONS. 14. OFFICES AND SHOPS MUST MAINTAIN ONE-HOUR FIRE RATED CONSTRUCTION FOR DOOR, DOOR JAMS, AND OFFICES AND SHOPS MUST MAINTAIN ONE-HOUR FIRE RATED CONSTRUCTION FOR DOOR, DOOR JAMS, AND WINDOWS. 15. PENETRATIONS BY PLASTIC PIPE OR CONDUIT THROUGH FIRE-RATED WALLS, PARTITIONS, SHAFTS, PENETRATIONS BY PLASTIC PIPE OR CONDUIT THROUGH FIRE-RATED WALLS, PARTITIONS, SHAFTS, AND FLOORS MUST BE FIRE-STOPPED BY AN APPROVED LISTED METHOD IN ACCORDANCE WITH ASTM E814, STANDARD TEST METHOD FOR FIRE TESTS OF THROUGH-PENETRATION FIRE STOPS OR UL 1479, FIRE TESTS OF THROUGH-PENETRATION FIRESTOPS.

AutoCAD SHX Text SPECIAL NOTE 1. ALL EXISTING UTILITIES SHOWN ON THE DRAWINGS ARE BASED ON AVAILABLE INFORMATION AND MUST BE TREATED AS APPROXIMATE ONLY. THE CONTRACTOR MUST TAKE PRECAUTIONARY MEASURES PRIOR TO AND DURING WORK/CONSTRUCTION SO AS NOT TO DAMAGE OR INTERRUPT THE BUILDING SERVICES OR ACTIVITIES. THE GOVERNMENT HAS NO LIABILITY FOR ANY MISHAP THAT MAY BE INCURRED. 2. AT NO TIME SHALL A STREET BE COMPLETELY BLOCKED PREVENTING EMERGENCY VEHICLE ACCESS TO A BUILDING UNLESS THERE IS ALTERNATE MEANS OF ACCESS. THE DSCC EMERGENCY DISPATCH SHALL BE CALLED IF A STREET IS TO BE PARTIALLY OR COMPLETELY BLOCKED. THE EMERGENCY DISPATCH PHONE NUMBER IS 614-692-1260. 3. ENSURE NFPA 502 SECTION 6.5 STANDARDS ARE FOLLOWED AT ALL TIMES IF APPLICABLE; 6.5.1 TRAFFIC CONTROL PROCEDURES SHALL BE ESTABLISHED SO THAT VEHICLES EITHER STOP OR PROCEED WITH CAUTION. 6.5.2 TRAFFIC SHALL NOT BE PERMITTED TO BLOCK OR OTHERWISE INTERFERE WITH RESPONSE OF EMERGENCY AND FIRE EQUIPMENT. TRAFFIC INCIDENT MANAGEMENT SHALL BE IN CONFORMANCE WITH CHAPTER 6I OF THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD), LATEST EDITION. 4. ACCESS TO ALL FIRE HYDRANTS SHALL BE READILY ACCESSIBLE AND FREE OF ANY OBSTRUCTIONS SUCH AS DEBRIS, EQUIPMENT, VEHICLES OR ANY OTHER TYPE OF OBSTRUCTION THAT WOULD HINDER FIREFIGHTING OPERATIONS. 5. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE SECTIONS OF UFC 3-600-01 (2006) AND NFPA 241 (2009) SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS. 6. A SITE INSPECTION AND PERMIT SHALL BE ISSUED BY THE FIRE PREVENTION OFFICE AT 614-692-2921 PRIOR TO ANY WELDING, CUTTING, OR HOT WORK BEING CONDUCTED. 7. HVAC DESIGN AND INSTALLATION MUST CONFORM TO ALL APPLICABLE SECTIONS OF NFPA 90A (2009) STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS AND UFC 4-010-01 (2003) DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS. 8. THE CONTRACTOR SHALL ENSURE THAT ALL PENETRATIONS ARE PROPERLY PROTECTED AS PER IAW UFC 3-600-01 (CURRENT EDITION).

AutoCAD SHX Text GENERAL NOTES 1. CONTRACTOR IS RESPONSIBLE FOR INCORPORATING THE REQUIREMENTS OF ALL DRAWINGS AND SPECIFICATIONS INTO THEIR SHOP DRAWINGS AND WORK. 2. IT SHALL BE THE CONTRACTOR'S SOLE RESPONSIBILITY TO FIELD VERIFY THE EXACT EXTENT OF WORK, WORKING CONDITIONS AND CONSTRAINTS PRIOR TO BIDDING. 3. DIMENSIONS SHOWN ON THE DRAWING SHALL BE VERIFIED IN THE FIELD. DO NOT SCALE THESE DRAWINGS, USE KNOWN DIMENSIONS. 4. THE CONTRACTOR SHALL INFORM THE CONTRACTING OFFICER IN WRITING OF ANY DEVIATION FROM THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL NOT BE RELIEVED OF THE RESPONSIBILITY FOR SUCH DEVIATION BY THE GOVERNMENT'S APPROVAL OF SHOP DRAWINGS, PRODUCT DATE, ETC., UNLESS THE CONTRACTOR HAS SPECIFICALLY INFORMED THE CONTRACTING OFFICER OF SUCH DEVIATION AT THE TIME OF SUBMISSION, AND THE CONTRACTING OFFICER HAS GIVEN WRITTEN APPROVAL TO THE SPECIFIC DEVIATION. 5. ALL THINGS WHICH, IN THE OPINION OF THE CONTRACTOR, APPEAR TO BE DEFICIENCIES, OMISSIONS, CONTRADICTIONS, AND AMBIGUITIES, IN THE PLANS AND SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER. PLANS AND/OR SPECIFICATIONS WILL BE CORRECTED, OR A WRITTEN INTERPRETATION OF THE ALLEGED DEFICIENCY, OMISSION, CONTRADICTION OR AMBIGUITY WILL BE MADE BY THE GOVERNMENT BEFORE THE AFFECTED WORK PROCEEDS. 6. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE CONTRACTING OFFICER, THE SCHEDULE OF WORK. 7. CONTRACTOR SHALL PROTECT EXISTING WALLS, EQUIPMENT, ETC., FROM DAMAGE DUE TO DEMOLITION AND/OR NEW WORK. ANY DAMAGE DONE TO GOVERNMENT PROPERTY DURING WORK/CONSTRUCTION SHALL BE REPAIRED IN KIND AND AT NO ADDITIONAL COST TO THE GOVERNMENT. ALL REPAIR WORK TO BE INSPECTED AND ACCEPTED BY THE GOVERNMENT. 8. ALL ADDITIONAL WORK PERFORMED BEYOND THE REQUIRED BASE CONTRACT, PRIOR TO THE APPROVAL OF THE CONTRACTING OFFICER, WILL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 9. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE TEMPORARY STRUCTURES AND OTHER PROTECTIVE DEVICES NECESSARY FOR THE EXECUTION OF THE WORK. 10. CONTRACTOR SHALL ENSURE THAT ALL WORK WILL BE DONE IN ACCORDANCE WITH NFPA 5000 BUILDING CONSTRUCTION AND SAFETY CODES. 11. ALL DEMOLITION AND DEBRIS SHALL BE HAULED AWAY FROM THE SITE DAILY AND IN ACCORDANCE WITH CURRENT LOCAL, STATE, AND FEDERAL REGULATIONS. 12. ALL WORK TO BE PERFORMED DURING DAYTIME HOURS UNLESS OTHERWISE SPECIFIED BY THE GOVERNMENT. 13. PROPER DUST CONTROL MUST BE IN PLACE TO PREVENT DUST FROM MIGRATING TO ADJACENT WORK AREAS. ASSOCIATES NEED TO BE INFORMED OF WORK BEING CONDUCTED. 14. SEALANT MUST HAVE SDS ON THE FILE FOR SAFETY/IH REVIEW FOR ALL PRODUCTS. PROPER VENTILATION IS REQUIRED TO KEEP FUMES/SMELL DOWN TO A LEVEL AS TO NOT HINDER ASSOCIATES. POSSIBLE IAQ SAMPLING BY CONTRACTORS DURING PROJECT AS WELL AS INFORMING ASSOCIATES OF EXPECTED WORK. 15. CONTRACTOR SHALL INSULATE ALL NEW DOMESTIC WATER PIPING WITH 1" ELASTOMERIC FOAM INSULATION. ALL NEW PIPING MUST BE APPROPRIATELY LABELED IN ACCORDANCE WITH ANSI/ASME A13.1-2007 STANDARD FOR THE IDENTIFICATION OF PIPES. 16. CONTRACTOR SHALL NOTIFY GOVERNMENT A MINIMUM OF 28 DAYS PRIOR TO BEGINNING WORK TO ALLOW SUFFICIENT TIME TO VACANT THE PREMISES.

AutoCAD SHX Text

(FAR 52.223-4).

AutoCAD SHX Text

6. CONTRACTOR SHALL ADHERE TO DSCC ASBESTOS CONTRACT SPECIFICATION - "REMOVAL

AutoCAD SHX Text

AND DISPOSAL OF ASBESTOS CONTAINING MATERIALS".

AutoCAD SHX Text

7. CONTRACTOR MUST PROVIDE TEMPORARY SUPPORT OF EXISTING STRUCTURES DURING ALL

AutoCAD SHX Text

PHASES OF CONSTRUCTION. IF A SAFETY CONCERN IS ENCOUNTERED, CONTRACTOR MUST

NOTIFY THE GOVERNMENT IMMEDIATELY.

D1 D1

D1

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text the biggest cubicle!

AutoCAD SHX Text

FAX

AutoCAD SHX Text 2-3956

AutoCAD SHX Text

HP600

AutoCAD SHX Text

PRINTER

AutoCAD SHX Text

NETWORK

AutoCAD SHX Text

PRINTER

AutoCAD SHX Text B/W

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AKS

AutoCAD SHX Text 30/24/48

AutoCAD SHX Text 30/30/78

AutoCAD SHX Text 24/36

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PRINTER

AutoCAD SHX Text

HP600

AutoCAD SHX Text 308-I-105

AutoCAD SHX Text 308-I-155A

AutoCAD SHX Text 308-I-166

AutoCAD SHX Text 308-I-171

AutoCAD SHX Text 308-I-170

AutoCAD SHX Text 308-I-169A

AutoCAD SHX Text 308-I-169

AutoCAD SHX Text 308-I-168

AutoCAD SHX Text 308-I-167

AutoCAD SHX Text 308-I-164

AutoCAD SHX Text 308-I-163

AutoCAD SHX Text 308-I-162B

AutoCAD SHX Text 308-I-162

AutoCAD SHX Text 308-I-161

AutoCAD SHX Text 308-I-119

AutoCAD SHX Text 308-I-160

AutoCAD SHX Text 308-I-159

AutoCAD SHX Text 308-I-148

AutoCAD SHX Text 308-I-165

AutoCAD SHX Text 308-I-158

AutoCAD SHX Text 308-I-154

AutoCAD SHX Text 308-I-153

AutoCAD SHX Text 308-I-150

AutoCAD SHX Text 308-I-149

AutoCAD SHX Text 308-I-155

AutoCAD SHX Text 308-I-157A

AutoCAD SHX Text 308-I-157

AutoCAD SHX Text 308-I-156A

AutoCAD SHX Text 308-I-156

AutoCAD SHX Text 308-I-144A

AutoCAD SHX Text 308-I-147

AutoCAD SHX Text 308-I-143

AutoCAD SHX Text 308-I-146

AutoCAD SHX Text 308-I-141

AutoCAD SHX Text 308-I-142

AutoCAD SHX Text 308-I-139

AutoCAD SHX Text 308-I-138

AutoCAD SHX Text 308-I-140

AutoCAD SHX Text 308-I-137A

AutoCAD SHX Text 308-I-137

AutoCAD SHX Text 308-I-134

AutoCAD SHX Text 308-I-133

AutoCAD SHX Text 308-I-131

AutoCAD SHX Text 308-I-127A

AutoCAD SHX Text 308-I-130

AutoCAD SHX Text 308-I-129

AutoCAD SHX Text 308-I-127

AutoCAD SHX Text 308-I-117

AutoCAD SHX Text 308-I-119A

AutoCAD SHX Text 308-I-125

AutoCAD SHX Text 308-I-124

AutoCAD SHX Text 308-I-123

AutoCAD SHX Text 308-I-122

AutoCAD SHX Text 308-I-121

AutoCAD SHX Text 308-I-120

AutoCAD SHX Text 308-I-118

AutoCAD SHX Text 308-I-118A

AutoCAD SHX Text 308-I-114A

AutoCAD SHX Text 308-I-115

AutoCAD SHX Text 308-I-114

AutoCAD SHX Text 308-I-113

AutoCAD SHX Text 308-I-109

AutoCAD SHX Text 308-I-112A

AutoCAD SHX Text 308-I-112

AutoCAD SHX Text 308-I-111

AutoCAD SHX Text 308-I-110

AutoCAD SHX Text 308-I-178

AutoCAD SHX Text 308-I-102

AutoCAD SHX Text 308-I-172

AutoCAD SHX Text 308-I-175

AutoCAD SHX Text 308-I-176

AutoCAD SHX Text 308-I-108A

AutoCAD SHX Text 308-I-107

AutoCAD SHX Text 308-I-104

AutoCAD SHX Text 308-I-108

AutoCAD SHX Text 308-I-103

AutoCAD SHX Text 308-I-177

AutoCAD SHX Text 308-I-101

AutoCAD SHX Text 308W-W-045

AutoCAD SHX Text 308W-W-044

AutoCAD SHX Text 308W-W-043

AutoCAD SHX Text 308W-W-042

AutoCAD SHX Text 308W-W-041

AutoCAD SHX Text 308W-W-040

AutoCAD SHX Text 308W-W-039

AutoCAD SHX Text 308W-W-038

AutoCAD SHX Text 308W-W-037

AutoCAD SHX Text 308S-W-036

AutoCAD SHX Text 308S-W-035

AutoCAD SHX Text 308S-W-034

AutoCAD SHX Text 308S-W-033

AutoCAD SHX Text 308S-W-032

AutoCAD SHX Text 308S-W-031

AutoCAD SHX Text 308S-W-029

AutoCAD SHX Text 308S-W-028

AutoCAD SHX Text 308E-W-014

AutoCAD SHX Text 308S-W-027

AutoCAD SHX Text 308E-W-025

AutoCAD SHX Text 308E-W-024

AutoCAD SHX Text 308E-W-023

AutoCAD SHX Text 308E-W-022

AutoCAD SHX Text 308E-W-021

AutoCAD SHX Text 308E-W-020

AutoCAD SHX Text 308E-W-019

AutoCAD SHX Text 308E-W-018

AutoCAD SHX Text 308E-W-017

AutoCAD SHX Text 308E-W-016

AutoCAD SHX Text 308E-W-015

AutoCAD SHX Text 308E-W-026

AutoCAD SHX Text 308W-E-019

AutoCAD SHX Text 308W-E-018

AutoCAD SHX Text 308W-E-017

AutoCAD SHX Text 308W-E-016

AutoCAD SHX Text 308S-E-015

AutoCAD SHX Text 308S-E-014

AutoCAD SHX Text 308S-E-013

AutoCAD SHX Text 308S-E-012

AutoCAD SHX Text 308S-E-011

AutoCAD SHX Text 308S-E-010

AutoCAD SHX Text 308S-E-009

AutoCAD SHX Text 308E-E-008

AutoCAD SHX Text 308N-E-007

AutoCAD SHX Text 308N-E-006

AutoCAD SHX Text 308N-E-005

AutoCAD SHX Text 308N-E-004

AutoCAD SHX Text 308N-E-002

AutoCAD SHX Text 308N-E-003

AutoCAD SHX Text 308E-W-013

AutoCAD SHX Text 147"X103"

AutoCAD SHX Text 147"X103"

AutoCAD SHX Text 69"X58"

AutoCAD SHX Text 147"x103"

AutoCAD SHX Text 147"x103"

AutoCAD SHX Text 45"x60"

AutoCAD SHX Text 73"x58"

AutoCAD SHX Text 147"x66"

AutoCAD SHX Text 147"X103"

AutoCAD SHX Text 147"X103"

AutoCAD SHX Text 107"X60"

AutoCAD SHX Text 308N-E-001

AutoCAD SHX Text 308N-W-005

AutoCAD SHX Text 308-I-116

AutoCAD SHX Text 308-I-126

AutoCAD SHX Text 308-I-139A

AutoCAD SHX Text 308-I-179

AutoCAD SHX Text 47-1/4"x60"

AutoCAD SHX Text 60"x60"

AutoCAD SHX Text 71"x60"

AutoCAD SHX Text 73"x60"

AutoCAD SHX Text 96"x54"

AutoCAD SHX Text 88"x36"

AutoCAD SHX Text 107"X60"

AutoCAD SHX Text 147"X103"

AutoCAD SHX Text 147"X103"

AutoCAD SHX Text 308N-W-003

AutoCAD SHX Text 308N-W-002

AutoCAD SHX Text 308N-W-001

AutoCAD SHX Text 308N-W-008

AutoCAD SHX Text 308N-W-007

AutoCAD SHX Text 308N-W-006

AutoCAD SHX Text 308N-W-004

AutoCAD SHX Text 308N-W-009

AutoCAD SHX Text 308N-W-010

AutoCAD SHX Text 308N-W-012

AutoCAD SHX Text 308N-W-011

AutoCAD SHX Text 69"x58"

AutoCAD SHX Text 68"x58"

AutoCAD SHX Text 44"x63"

AutoCAD SHX Text 44"x63"

AutoCAD SHX Text 44"x63"

AutoCAD SHX Text 44"x63"

AutoCAD SHX Text 44"x63"

AutoCAD SHX Text 44"x63"

AutoCAD SHX Text 69"x58"

AutoCAD SHX Text 69"x58"

AutoCAD SHX Text 68"x58"

AutoCAD SHX Text 148"x103"

AutoCAD SHX Text 68"x58"

AutoCAD SHX Text 148"x103"

AutoCAD SHX Text 94"x58"

AutoCAD SHX Text 93"x58"

AutoCAD SHX Text 34"x56"

AutoCAD SHX Text 83"x58"

AutoCAD SHX Text 83"x58"

AutoCAD SHX Text 71"x56"

AutoCAD SHX Text 72"x56"

AutoCAD SHX Text 95"x58"

AutoCAD SHX Text 67"x56"

AutoCAD SHX Text 308-I-144

AutoCAD SHX Text 308-I-152

AutoCAD SHX Text

PRINTER

AutoCAD SHX Text

SUBMITTED BY:

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR.

AutoCAD SHX Text

FACILITIES ENGINEERING OFFICE

AutoCAD SHX Text

BUILDING 308

AutoCAD SHX Text

INSTALLATION MANAGEMENT DIVISION

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

PROJECT NO.

AutoCAD SHX Text

PLOT DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

MARK

AutoCAD SHX Text DEFENSE LOGISTICS AGENCY DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990

AutoCAD SHX Text

SHEET REFERENCE NUMBER:

AutoCAD SHX Text

CUSTOMER

AutoCAD SHX Text

DF-FCE (ENVIRONMENTAL)

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

FACILITY ENGINEER

AutoCAD SHX Text

DF-FCO (SAFETY)

AutoCAD SHX Text

APPROVED BY:

AutoCAD SHX Text

DF-FCS (SECURITY)

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DEPUTY FACILITY ENGINEER

AutoCAD SHX Text 3-1691

AutoCAD SHX Text

AS STATED

AutoCAD SHX Text 4-Jun-19

AutoCAD SHX Text

KENT KLINGLER

AutoCAD SHX Text

ADAM DECARLO

AutoCAD SHX Text A-101

AutoCAD SHX Text

EXISTING CONDITIONS

AutoCAD SHX Text

CSC-19300

AutoCAD SHX Text

BUILDING 308 IMPROVEMENTS

AutoCAD SHX Text

BUILDING 308 EXISTING CONDITIONS

AutoCAD SHX Text

SCALE: 3/32" = 1'

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

WORKING LIMITS (AREA 1)

AutoCAD SHX Text

WORKING LIMITS (AREA 2)

REMOVE EXISTING WINDOWS AND FILL OPENING. PRESUMED ACM PRESENT. SEE WINDOW SCHEDULE ON SHEET A-112.

D1 D1

D1

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text the biggest cubicle!

AutoCAD SHX Text

FAX

AutoCAD SHX Text 2-3956

AutoCAD SHX Text

HP600

AutoCAD SHX Text

PRINTER

AutoCAD SHX Text

NETWORK

AutoCAD SHX Text

PRINTER

AutoCAD SHX Text B/W

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PRINTER

AutoCAD SHX Text

HP600

AutoCAD SHX Text 308-I-155A

AutoCAD SHX Text 308-I-166

AutoCAD SHX Text 308-I-171

AutoCAD SHX Text 308-I-170

AutoCAD SHX Text 308-I-169A

AutoCAD SHX Text 308-I-169

AutoCAD SHX Text 308-I-168

AutoCAD SHX Text 308-I-167

AutoCAD SHX Text 308-I-164

AutoCAD SHX Text 308-I-163

AutoCAD SHX Text 308-I-162B

AutoCAD SHX Text 308-I-162

AutoCAD SHX Text 308-I-161

AutoCAD SHX Text 308-I-160

AutoCAD SHX Text 308-I-159

AutoCAD SHX Text 308-I-148

AutoCAD SHX Text 308-I-165

AutoCAD SHX Text 308-I-158

AutoCAD SHX Text 308-I-154

AutoCAD SHX Text 308-I-153

AutoCAD SHX Text 308-I-150

AutoCAD SHX Text 308-I-149

AutoCAD SHX Text 308-I-155

AutoCAD SHX Text 308-I-157A

AutoCAD SHX Text 308-I-157

AutoCAD SHX Text 308-I-156A

AutoCAD SHX Text 308-I-156

AutoCAD SHX Text 308-I-144A

AutoCAD SHX Text 308-I-147

AutoCAD SHX Text 308-I-143

AutoCAD SHX Text 308-I-146

AutoCAD SHX Text 308-I-178

AutoCAD SHX Text 308W-W-041

AutoCAD SHX Text 308W-W-040

AutoCAD SHX Text 308W-W-039

AutoCAD SHX Text 308W-W-038

AutoCAD SHX Text 308W-W-037

AutoCAD SHX Text 308S-W-036

AutoCAD SHX Text 308S-W-035

AutoCAD SHX Text 308S-W-034

AutoCAD SHX Text 308S-W-033

AutoCAD SHX Text 308S-W-032

AutoCAD SHX Text 308S-W-031

AutoCAD SHX Text 308W-E-016

AutoCAD SHX Text 308S-E-015

AutoCAD SHX Text 308S-E-014

AutoCAD SHX Text 47-1/4"x60"

AutoCAD SHX Text 60"x60"

AutoCAD SHX Text 71"x60"

AutoCAD SHX Text 73"x60"

AutoCAD SHX Text 96"x54"

AutoCAD SHX Text 94"x58"

AutoCAD SHX Text 93"x58"

AutoCAD SHX Text 34"x56"

AutoCAD SHX Text 83"x58"

AutoCAD SHX Text 83"x58"

AutoCAD SHX Text 71"x56"

AutoCAD SHX Text 308-I-144

AutoCAD SHX Text 308-I-152

AutoCAD SHX Text

PRINTER

AutoCAD SHX Text GENERAL NOTES: CONTRACTOR SHALL SUBMIT A COMPLETE WORK PLAN THAT INCLUDES, BUT NOT LIMITED TO, WORK SCHEDULE, SEQUENCE OF WORK, SHOP DRAWINGS, CALCULATIONS, ALL EQUIPMENT AND THEIR ACCESSORIES FOR APPROVAL PRIOR TO STARTING WORK. EXISTING EQUIPMENT SHOWN IS IN APPROXIMATE LOCATIONS. CONTRACTOR SHALL FIELD VERIFY LOCATIONS PRIOR TO BIDDING WORK. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS NOT TO DAMAGE EXISTING STRUCTURES THAT SHALL REMAIN IN PLACE. ALL EXISTING OFFICE FURNITURE WITHIN WORKING LIMITS TO BE REMOVED BY GOVERNMENT, INCLUDING PERIMETER OFFICES, EXCEPT AS NOTED. SEE FIRE PROTECTION NOTES ON SHEET G-002 FOR FIRE ALARM AND SPRINKLER SYSTEM DESIGN REQUIREMENTS. EXISTING CARPET WITHIN WORKING LIMITS TO BE REMOVED, INCLUDING ALL COVE BASE. EXISTING SUSPENDED CEILING SYSTEM WITHIN WORKING LIMITS TO BE REMOVED. SEE PROPOSED REFLECTED CEILING PLAN ON SHEET A-109. APPROXIMATELY 315 LF OF EXISTING WALL TO BE REMOVED. (~210 LF WOOD FRAMING AND ~105 LF OF CMU BLOCK WALL) ASSUME WALLS ARE 10 FT HIGH. REFER TO NOTES ON SHEET G-002.

AutoCAD SHX Text CODED NOTES: 1. REMOVE DOOR, FRAME, AND ASSOCIATED HARDWARE AND DISPOSE. REMOVE DOOR 308-I-144 FRAME ONLY. REMOVE DOOR, FRAME, AND ASSOCIATED HARDWARE AND DISPOSE. REMOVE DOOR 308-I-144 FRAME ONLY. DOOR 308-I-155A IS KNOWN TO CONTAIN LEAD AND MUST BE PROPERLY DISPOSED OF IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL REGULATIONS. SEE DOOR SCHEDULE ON SHEET A-111 FOR COMPLETE LIST OF DOORS TO BE REPLACED. 2. REMOVE FLOORING DOWN TO SUB-FLOOR. REMOVE FLOORING DOWN TO SUB-FLOOR. 3. REMOVE INTERIOR WINDOW IN ROOM 164 AND EXTERIOR WINDOW IN ROOM 152 AND DISPOSE. SEE WINDOW SCHEDULE REMOVE INTERIOR WINDOW IN ROOM 164 AND EXTERIOR WINDOW IN ROOM 152 AND DISPOSE. SEE WINDOW SCHEDULE ON SHEET A-112 FOR COMPLETE LIST OF WINDOWS TO BE REPLACED. 4. REMOVE EXHAUST FAN AND LOUVERED GRATE IN BLOCK WALL (ROOM 155). REMOVE EXHAUST FAN AND LOUVERED GRATE IN BLOCK WALL (ROOM 155). 5. REMOVE WALL COVERINGS TO EXPOSE STUDS. REMOVE WALL COVERINGS TO EXPOSE STUDS. 6. REMOVE FLOORING AND RAISED THRESHOLDS (TWO TOTAL) TO SUB-FLOOR. OLD SHOWER ROOM FLOOR IN ROOM 145 REMOVE FLOORING AND RAISED THRESHOLDS (TWO TOTAL) TO SUB-FLOOR. OLD SHOWER ROOM FLOOR IN ROOM 145 IS SLOPED TO DRAIN. FLOOR WILL NEED LEVELED IN PREPARATION OF NEW FLOORING. CAP EXISTING PLUMBING AND ABANDON IN PLACE. 7. REMOVE EXISTING MECHANICAL ROOM OVERHEAD ROLL-UP DOOR, FRAME, AND ACCESSORIES AND STORE FOR REMOVE EXISTING MECHANICAL ROOM OVERHEAD ROLL-UP DOOR, FRAME, AND ACCESSORIES AND STORE FOR RE-INSTALLATION DURING NEW WORK PHASE. 8. CONTRACTOR TO INVESTIGATE CONDITION AND OPERATION OF PUMP ROOM LOCATED IN BASEMENT UNDER THE SW CONTRACTOR TO INVESTIGATE CONDITION AND OPERATION OF PUMP ROOM LOCATED IN BASEMENT UNDER THE SW CORNER OFFICE (NEW ROOM #160A). IF DETERMINED TO BE INACTIVE OR OBSOLETE, CONTRACTOR TO SUBMIT A PLAN FOR GOVERNMENT APPROVAL TO REMOVE ALL EXISTING EQUIPMENT AND BACKFILL AND SEAL THE SPACE.

AutoCAD SHX Text

SUBMITTED BY:

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR.

AutoCAD SHX Text

FACILITIES ENGINEERING OFFICE

AutoCAD SHX Text

BUILDING 308

AutoCAD SHX Text

INSTALLATION MANAGEMENT DIVISION

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

PROJECT NO.

AutoCAD SHX Text

PLOT DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

MARK

AutoCAD SHX Text DEFENSE LOGISTICS AGENCY DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990

AutoCAD SHX Text

SHEET REFERENCE NUMBER:

AutoCAD SHX Text

CUSTOMER

AutoCAD SHX Text

DF-FCE (ENVIRONMENTAL)

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

FACILITY ENGINEER

AutoCAD SHX Text

DF-FCO (SAFETY)

AutoCAD SHX Text

APPROVED BY:

AutoCAD SHX Text

DF-FCS (SECURITY)

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DEPUTY FACILITY ENGINEER

AutoCAD SHX Text 3-1691

AutoCAD SHX Text

AS STATED

AutoCAD SHX Text 4-Jun-19

AutoCAD SHX Text

KENT KLINGLER

AutoCAD SHX Text

ADAM DECARLO

AutoCAD SHX Text A-102

AutoCAD SHX Text

DEMOLITION PLAN - AREA 1

AutoCAD SHX Text

CSC-19300

AutoCAD SHX Text

BUILDING 308 IMPROVEMENTS

AutoCAD SHX Text

BUILDING 308 DEMO PLAN - AREA 1

AutoCAD SHX Text

SCALE: 3/16" = 1'

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SEE SHEET A-104

AutoCAD SHX Text

SEE SHEET A-104

AutoCAD SHX Text

SEE SHEET A-104

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DEMO EXISTING WALL SEE GENERAL NOTES THIS SHEET

AutoCAD SHX Text

DEMO EXISTING WALL SEE GENERAL NOTES THIS SHEET

AutoCAD SHX Text

DEMO EXISTING WALLS SEE GENERAL NOTES THIS SHEET

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SEE SHEET A-104

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text DEMO EXISTING WALL. SEE GENERAL NOTES THIS SHEET. CONTRACTOR TO PROVIDE TEMPORARY SUPPORT UNTIL NEW STRUCTURAL MEMBER IS INSTALLED. EXISTING DECKING SYSTEM ABOVE IS TO REMAIN.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text CONTRACTOR IS RESPONSIBLE FOR REMOVING AND REPLACING ALL FURNITURE AND EQUIPMENT IN ROOM 155.

AutoCAD SHX Text

AutoCAD SHX Text

PUMP ROOM UNDER OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

REMOVE EXISTING WALLGUARD AND REPLACE W/ NEW (APPROX. 70 LF).70 LF).

16'-0"

15'-0"

18'-0"3'-3"

4'-10

5'-3"

7'-0"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 308-I-178

AutoCAD SHX Text 308-I-102

AutoCAD SHX Text 308-I-172

AutoCAD SHX Text 308-I-175

AutoCAD SHX Text 308-I-176

AutoCAD SHX Text 308W-W-042

AutoCAD SHX Text 308W-E-019

AutoCAD SHX Text 308W-E-018

AutoCAD SHX Text 308W-E-017

AutoCAD SHX Text 88"x36"

AutoCAD SHX Text

SUBMITTED BY:

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR.

AutoCAD SHX Text

FACILITIES ENGINEERING OFFICE

AutoCAD SHX Text

BUILDING 308

AutoCAD SHX Text

INSTALLATION MANAGEMENT DIVISION

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

PROJECT NO.

AutoCAD SHX Text

PLOT DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

MARK

AutoCAD SHX Text DEFENSE LOGISTICS AGENCY DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990

AutoCAD SHX Text

SHEET REFERENCE NUMBER:

AutoCAD SHX Text

CUSTOMER

AutoCAD SHX Text

DF-FCE (ENVIRONMENTAL)

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

FACILITY ENGINEER

AutoCAD SHX Text

DF-FCO (SAFETY)

AutoCAD SHX Text

APPROVED BY:

AutoCAD SHX Text

DF-FCS (SECURITY)

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DEPUTY FACILITY ENGINEER

AutoCAD SHX Text 3-1691

AutoCAD SHX Text

AS STATED

AutoCAD SHX Text 4-Jun-19

AutoCAD SHX Text

KENT KLINGLER

AutoCAD SHX Text

ADAM DECARLO

AutoCAD SHX Text A-103

AutoCAD SHX Text

DEMOLITION PLAN - AREA 2

AutoCAD SHX Text

CSC-19300

AutoCAD SHX Text

BUILDING 308 IMPROVEMENTS

AutoCAD SHX Text

BUILDING 308 DEMO PLAN - AREA 2

AutoCAD SHX Text

SCALE: 3/16" = 1'

AutoCAD SHX Text

NORTH

AutoCAD SHX Text GENERAL NOTES: CONTRACTOR SHALL SUBMIT A COMPLETE WORK PLAN THAT INCLUDES, BUT NOT LIMITED TO, WORK SCHEDULE, SEQUENCE OF WORK, SHOP DRAWINGS, CALCULATIONS, ALL EQUIPMENT AND THEIR ACCESSORIES FOR APPROVAL PRIOR TO STARTING WORK. EXISTING EQUIPMENT SHOWN IS IN APPROXIMATE LOCATIONS. CONTRACTOR SHALL FIELD VERIFY LOCATIONS PRIOR TO BIDDING WORK. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS NOT TO DAMAGE EXISTING STRUCTURES THAT SHALL REMAIN IN PLACE. ALL EXISTING OFFICE FURNITURE WITHIN WORKING LIMITS TO BE REMOVED BY GOVERNMENT, INCLUDING PERIMETER OFFICES. RELOCATE EXISTING FIRE SUPPRESSION PIPING AND ASSOCIATED HARDWARE AND FITTINGS AS REQUIRED. SEE FIRE PROTECTION NOTES ON SHEET G-002 FOR FIRE ALARM AND SPRINKLER SYSTEM SEE FIRE PROTECTION NOTES ON SHEET G-002 FOR FIRE ALARM AND SPRINKLER SYSTEM DESIGN REQUIREMENTS. APPROXIMATELY 90 LF OF EXISTING WALL TO BE REMOVED. ASSUME WALLS ARE 8 FT HIGH. EXISTING CARPET WITHIN WORKING LIMITS TO BE REMOVED INCLUDING COVE BASE. EXISTING SUSPENDED CEILING SYSTEM WITHIN WORKING LIMITS TO BE REMOVED. SEE PROPOSED REFLECTED CEILING PLAN ON SHEET A-109. REFER TO NOTES ON SHEET G-002.

AutoCAD SHX Text CODED NOTES: 1. REMOVE DOOR, FRAME, AND ASSOCIATED HARDWARE AND DISPOSE. SEE DOOR SCHEDULE ON SHEET A-111 REMOVE DOOR, FRAME, AND ASSOCIATED HARDWARE AND DISPOSE. SEE DOOR SCHEDULE ON SHEET A-111 FOR COMPLETE LIST OF DOORS TO BE REPLACED. TO BE REPLACED. 2. REMOVE FLOORING DOWN TO SUB-FLOOR. REMOVE FLOORING DOWN TO SUB-FLOOR. 3. REMOVE RAISED STORAGE PLATFORM AND STEPS IN THEIR ENTIRETY AND DISPOSE. REMOVE RAISED STORAGE PLATFORM AND STEPS IN THEIR ENTIRETY AND DISPOSE. 4. PATCH OPENING IN EXISTING WALL. PATCH TO MATCH NEW WALL FINISH. PATCH OPENING IN EXISTING WALL. PATCH TO MATCH NEW WALL FINISH. 5. REMOVE EXISTING MIRROR, PAPER TOWEL DISPENSER, SINK, SOAP DISPENSER, TOILET, TOILET TISSUE REMOVE EXISTING MIRROR, PAPER TOWEL DISPENSER, SINK, SOAP DISPENSER, TOILET, TOILET TISSUE HOLDER AND VANITY AND DISPOSE. CAP EXISTING PLUMBING AND ABANDON IN PLACE. 6. REMOVE EXISTING CEILING TILES, GRID, AND LIGHT FIXTURES AND DISPOSE. REMOVE EXISTING CEILING TILES, GRID, AND LIGHT FIXTURES AND DISPOSE. 7. REMOVE EXISTING WINDOW AND FRAME. SEE WINDOW SCHEDULE ON SHEET A-112. REMOVE EXISTING WINDOW AND FRAME. SEE WINDOW SCHEDULE ON SHEET A-112.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DEMO EXISTING WALLS SEE GENERAL NOTES THIS SHEET

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DEMO EXISTING WALLS SEE GENERAL NOTES THIS SHEET

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 308-I-171

AutoCAD SHX Text 308-I-170

AutoCAD SHX Text 308-I-169A

AutoCAD SHX Text 308-I-168

AutoCAD SHX Text 308W-E-016

AutoCAD SHX Text

AutoCAD SHX Text 308-I-160

AutoCAD SHX Text 308S-E-015

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 308-I-153

AutoCAD SHX Text 308S-W-035

AutoCAD SHX Text 308S-W-034

AutoCAD SHX Text 308S-W-033

AutoCAD SHX Text 93"x58"

AutoCAD SHX Text 34"x56"

AutoCAD SHX Text 83"x58"

AutoCAD SHX Text 308-I-152

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 308-I-144A

AutoCAD SHX Text 308-I-143

AutoCAD SHX Text 308-I-144

AutoCAD SHX Text

SUBMITTED BY:

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR.

AutoCAD SHX Text

FACILITIES ENGINEERING OFFICE

AutoCAD SHX Text

BUILDING 308

AutoCAD SHX Text

INSTALLATION MANAGEMENT DIVISION

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

PROJECT NO.

AutoCAD SHX Text

PLOT DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

MARK

AutoCAD SHX Text DEFENSE LOGISTICS AGENCY DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990

AutoCAD SHX Text

SHEET REFERENCE NUMBER:

AutoCAD SHX Text

CUSTOMER

AutoCAD SHX Text

DF-FCE (ENVIRONMENTAL)

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

FACILITY ENGINEER

AutoCAD SHX Text

DF-FCO (SAFETY)

AutoCAD SHX Text

APPROVED BY:

AutoCAD SHX Text

DF-FCS (SECURITY)

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DEPUTY FACILITY ENGINEER

AutoCAD SHX Text 3-1691

AutoCAD SHX Text

AS STATED

AutoCAD SHX Text 4-Jun-19

AutoCAD SHX Text

KENT KLINGLER

AutoCAD SHX Text

ADAM DECARLO

AutoCAD SHX Text A-104

AutoCAD SHX Text

DEMOLITION PLAN - RESTROOMS/BREAKROOM

AutoCAD SHX Text

CSC-19300

AutoCAD SHX Text

BUILDING 308 IMPROVEMENTS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NORTH

AutoCAD SHX Text DEMO NOTES: : 1. REMOVE TOILET, TOILET PAPER RECEPTACLE, AND SEAT COVER RECEPTACLE. REMOVE TOILET, TOILET PAPER RECEPTACLE, AND SEAT COVER RECEPTACLE. FIXTURE TO BE RECYCLED. FIXTURE TO BE RECYCLED. 2. REMOVE LAVATORY AND VANITY. FIXTURES TO BE RECYCLED. REMOVE LAVATORY AND VANITY. FIXTURES TO BE RECYCLED. 3. REMOVE PAPER TOWEL DISPENSER, SOAP DISPENSER, AND MIRROR, AND DISPOSE. REMOVE PAPER TOWEL DISPENSER, SOAP DISPENSER, AND MIRROR, AND DISPOSE. 4. REMOVE EXISTING WALL HEATER AND DISPOSE. REMOVE EXISTING WALL HEATER AND DISPOSE. 5. REMOVE DOOR, FRAME, AND ASSOCIATED HARDWARE AND DISPOSE. REMOVE DOOR, FRAME, AND ASSOCIATED HARDWARE AND DISPOSE. 6. REMOVE FLOORING DOWN TO SUB-FLOOR AND INTERIOR WALL AND CEILING REMOVE FLOORING DOWN TO SUB-FLOOR AND INTERIOR WALL AND CEILING COVERINGS TO EXPOSE STUD FRAMING. 7. REMOVE EXISTING WATER FOUNTAIN AND DISPOSE, ROOM 170 ONLY. DO NOT REMOVE EXISTING WATER FOUNTAIN AND DISPOSE, ROOM 170 ONLY. DO NOT REPLACE. USE AND ADJUST EXISTING PLUMBING AS NECESSARY FOR NEW WATER COOLER INSTALLATION DURING NEW WORK PHASE.

AutoCAD SHX Text

SCALE: 3/16"=1'

AutoCAD SHX Text

BUILDING 308 DEMO WORK ROOMS 170 & 171

AutoCAD SHX Text

RESTROOM 171:

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

SCALE: 3/16"=1'

AutoCAD SHX Text

BUILDING 308 DEMO WORK ROOM 160

AutoCAD SHX Text

RESTROOM 160:

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

SCALE: 3/16"=1'

AutoCAD SHX Text

BUILDING 308 DEMO WORK ROOMS 151 & 152

AutoCAD SHX Text

ROOM 151 & RESTROOM 152:

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text DEMO NOTES: : 1. REMOVE TOILET. FIXTURE TO BE RECYCLED. REMOVE TOILET. FIXTURE TO BE RECYCLED. 2. REMOVE TOILET PARTITIONS AND ACCESSORIES AND DISPOSE. ACCESSORIES INCLUDE REMOVE TOILET PARTITIONS AND ACCESSORIES AND DISPOSE. ACCESSORIES INCLUDE GRAB BARS, TOILET PAPER RECEPTACLE, SEAT COVER RECEPTACLE, AND GRAB BARS, TOILET PAPER RECEPTACLE, SEAT COVER RECEPTACLE, AND SANITARY NAPKIN RECEPTACLE. 3. REMOVE LAVATORY, COUNTERTOP, AND VANITY. FIXTURES TO BE RECYCLED. REMOVE LAVATORY, COUNTERTOP, AND VANITY. FIXTURES TO BE RECYCLED. 4. REMOVE PAPER TOWEL DISPENSER, SOAP DISPENSER, AND MIRROR, AND DISPOSE. REMOVE PAPER TOWEL DISPENSER, SOAP DISPENSER, AND MIRROR, AND DISPOSE. 5. REMOVE DOOR, FRAME, AND ASSOCIATED HARDWARE AND DISPOSE. REMOVE DOOR, FRAME, AND ASSOCIATED HARDWARE AND DISPOSE. 6. REMOVE EXISTING BI-FOLD ACCESS DOOR AND DISPOSE. EXISTING WATER HEATER REMOVE EXISTING BI-FOLD ACCESS DOOR AND DISPOSE. EXISTING WATER HEATER TO REMAIN. 7. REMOVE FLOORING DOWN TO SUB-FLOOR AND INTERIOR WALL COVERINGS TO REMOVE FLOORING DOWN TO SUB-FLOOR AND INTERIOR WALL COVERINGS TO EXPOSE STUD FRAMING. 8. APPROXIMATELY 12 LF OF EXISTING WALL TO BE REMOVED. ASSUME WALLS ARE APPROXIMATELY 12 LF OF EXISTING WALL TO BE REMOVED. ASSUME WALLS ARE 10 FT HIGH. 9. REMOVE CEILING TILES, GRID, AND LIGHT FIXTURES AND DISPOSE.REMOVE CEILING TILES, GRID, AND LIGHT FIXTURES AND DISPOSE.

AutoCAD SHX Text

AutoCAD SHX Text DEMO NOTES: : 1. REMOVE TOILET AND URINAL. FIXTURES TO BE RECYCLED. REMOVE TOILET AND URINAL. FIXTURES TO BE RECYCLED. 2. REMOVE TOILET PARTITIONS AND ACCESSORIES AND DISPOSE. ACCESSORIES INCLUDE REMOVE TOILET PARTITIONS AND ACCESSORIES AND DISPOSE. ACCESSORIES INCLUDE GRAB BARS, TOILET PAPER RECEPTACLE, AND SEAT COVER RECEPTACLE. GRAB BARS, TOILET PAPER RECEPTACLE, AND SEAT COVER RECEPTACLE. 3. REMOVE LAVATORY. FIXTURES TO BE RECYCLED. REMOVE LAVATORY. FIXTURES TO BE RECYCLED. 4. REMOVE PAPER TOWEL DISPENSER, SOAP DISPENSER, AND MIRRORS, AND DISPOSE. REMOVE PAPER TOWEL DISPENSER, SOAP DISPENSER, AND MIRRORS, AND DISPOSE. 5. REMOVE DOOR, FRAME, AND ASSOCIATED HARDWARE AND DISPOSE. REMOVE DOOR, FRAME, AND ASSOCIATED HARDWARE AND DISPOSE. 6. REMOVE FLOORING DOWN TO SUB-FLOOR AND INTERIOR WALL COVERINGS TO REMOVE FLOORING DOWN TO SUB-FLOOR AND INTERIOR WALL COVERINGS TO EXPOSE STUD FRAMING. 7. REMOVE EXISTING BASE AND WALL CABINETS, SINK, COUNTERTOPS, AND PLUMBING REMOVE EXISTING BASE AND WALL CABINETS, SINK, COUNTERTOPS, AND PLUMBING FIXTURES. ROOM 151 ONLY. 8. APPROXIMATELY 45 LF OF EXISTING WALL TO BE REMOVED. ASSUME WALLS ARE APPROXIMATELY 45 LF OF EXISTING WALL TO BE REMOVED. ASSUME WALLS ARE 10 FT HIGH. 9. REMOVE EXTERIOR GLASS BLOCK WINDOW IN ROOM 152 AND DISPOSE. REMOVE EXTERIOR GLASS BLOCK WINDOW IN ROOM 152 AND DISPOSE. 10. REMOVE EXISTING WALL HEATER AND DISPOSE. REMOVE EXISTING WALL HEATER AND DISPOSE. 11. REMOVE CEILING TILES, GRID, AND LIGHT FIXTURES AND DISPOSE. (ROOMS 151 & 152). REMOVE CEILING TILES, GRID, AND LIGHT FIXTURES AND DISPOSE. (ROOMS 151 & 152). 12. REMOVE FLOOR DRAIN. ABANDON AND CAP IN PLACE. REMOVE FLOOR DRAIN. ABANDON AND CAP IN PLACE.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text GENERAL NOTES: CONTRACTOR SHALL SUBMIT A COMPLETE WORK PLAN THAT INCLUDES, BUT NOT LIMITED TO, WORK SCHEDULE, SEQUENCE OF WORK, SHOP DRAWINGS, CALCULATIONS, ALL EQUIPMENT AND THEIR ACCESSORIES FOR APPROVAL PRIOR TO STARTING WORK. EXISTING EQUIPMENT SHOWN IS IN APPROXIMATE LOCATIONS. CONTRACTOR SHALL FIELD VERIFY LOCATIONS. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS NOT TO DAMAGE EXISTING STRUCTURES THAT SHALL REMAIN IN PLACE. SEE NOTES ON SHEET G-002.

AutoCAD SHX Text

AutoCAD SHX Text 160A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

SCALE: 3/16"=1'

AutoCAD SHX Text

BUILDING 308 DEMO WORK ROOM 143

AutoCAD SHX Text

RESTROOM 143:

AutoCAD SHX Text DEMO NOTES: : 1. REMOVE TOILETS (2 TOTAL) AND URINALS (2 TOTAL). FIXTURES TO BE RECYCLED. REMOVE TOILETS (2 TOTAL) AND URINALS (2 TOTAL). FIXTURES TO BE RECYCLED. 2. REMOVE TOILET PARTITIONS AND ACCESSORIES AND DISPOSE. ACCESSORIES INCLUDE REMOVE TOILET PARTITIONS AND ACCESSORIES AND DISPOSE. ACCESSORIES INCLUDE GRAB BARS, TOILET PAPER RECEPTACLE, AND SEAT COVER RECEPTACLE. GRAB BARS, TOILET PAPER RECEPTACLE, AND SEAT COVER RECEPTACLE. 3. REMOVE LAVATORIES (2 TOTAL). FIXTURES TO BE RECYCLED. REMOVE LAVATORIES (2 TOTAL). FIXTURES TO BE RECYCLED. 4. REMOVE PAPER TOWEL DISPENSER, SOAP DISPENSER, AND MIRRORS, AND DISPOSE. REMOVE PAPER TOWEL DISPENSER, SOAP DISPENSER, AND MIRRORS, AND DISPOSE. 5. REMOVE DOOR, FRAME, AND ASSOCIATED HARDWARE AND DISPOSE. REMOVE DOOR, FRAME, AND ASSOCIATED HARDWARE AND DISPOSE. 6. REMOVE FLOORING DOWN TO SUB-FLOOR AND INTERIOR WALL COVERINGS TO REMOVE FLOORING DOWN TO SUB-FLOOR AND INTERIOR WALL COVERINGS TO EXPOSE STUD FRAMING. 7. REMOVE EXISTING MOP SINK AND DISPOSE. REMOVE EXISTING MOP SINK AND DISPOSE. 8. REMOVE CEILING TILES, GRID, AND LIGHT FIXTURES AND DISPOSE.REMOVE CEILING TILES, GRID, AND LIGHT FIXTURES AND DISPOSE.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

XX

XXXX XX

XX

XX

XX

XX

XX

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EWC

AutoCAD SHX Text

EWC

AutoCAD SHX Text 160A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text…