Japan_PCB_bid_schedule.xlsx

XLSX spreadsheet 32 KB Posted

Attached to
Japan PCBs
Solicitation number
SP4500-15-R-0001
Issued by

About this file

Bid Schedule. Use this document to submit price proposals.

View the file

Other files

File Type Posted
Amendment_02_SP450015R0001.pdf PDF
Amend_01.pdf PDF
SP450015R0001_Solicitation.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Base Period Japan PCB Bid Schedule 18 Month Base Period

6300-7990 SPECIAL SERVICES
CLINDescriptionEst. QTYU/MUnit CostTotal
6509MFShipping Maniefests/Documentation [see 3.4]300ea$ - 0$ - 0
6610WPPackaging material disposal service [see 3.1]100ea$ - 0$ - 0
6311AAProvide service to place waste in containers - up to one 5 gal container10ea$ - 0$ - 0
6311BBProvide service to place waste in containers - one non-bulk container greater than 5 gal10ea$ - 0$ - 0
6312C2Provide container, 5 gal, UN 1H1/Y1.8/100 closed top, plastic, new10ea$ - 0$ - 0
6312E2Provide container, 55 gal, 1A1, closed top, steel, reconditioned5ea$ - 0$ - 0
6312F2Provide container, 85 gal UN1H2/X435/S or UN1H2T/Y320/S removable head (dual rated liquid/solid) plastic, new5ea$ - 0$ - 0
7990Overage surcharge for PCB items and containers when nine (9) months have elapsed between the out-of-service date and delivery order removal date [see 3.3]1,000lbs$ - 0$ - 0
Profile Based CLINs
FLAMMABLE/COMBUSTIBLE/IGNITABLE
Base CLINDescriptionSuffixEst. Qty.U/MUnit CostTotal
FL03Flammable Liquids/Solids/Sludges/Debris, i.e. tank sludge, lubricants, paint-related waste, adhesives, rags, filters, PPE, with <50ppm PCBs Physical State: Various Permissible Waste Codes: D001-2, D004-43, Listed Note: contract unique CLIN descriptionC12EA$ - 0$ - 0
C22EA$ - 0$ - 0
C32EA$ - 0$ - 0
C45EA$ - 0$ - 0
0
Base CLINDescriptionSuffixEst. Qty.U/MUnit CostTotal
PC01PCB and PCB/RCRA-Mixed Waste Contaminated with or Containing >=50 ppm Source, i.e., Debris, Sludge, Water, Leaking Capacitors, Fluids other than Transformer Mineral Oil. Certificate of Destruction Required. [2.2] Physical State: Various Permissible Waste Codes: Characteristic, ListedC75,000LB$ - 0$ - 0
PC02PCB Mineral Oil from Transformers, 1-49 ppm PCBs, Non-RCRA [2.2] Physical State: Liquid Permissible Waste Codes: N/AC719,000LB$ - 0$ - 0
PC03PCB Mineral Oil from Transformers, 50-4,000 ppm PCBs. Non-RCRA, Certificate of Recycling or Destruction Required. [2.2]

Physical State: Liquid

Permissible Waste Codes: N/AC71,500LB$ - 0$ - 0
PC04PCB Mineral Oil , Water, Other Fluids, >4,000 ppm PCBs. Certificate of Destruction Required. [2.2] Physical State: Liquid Permissible Waste Codes: Characteristic, ListedC7700LB$ - 0$ - 0
PC05PCB Oil-Filled Capacitors/Equipment other than Transformers, may include cable with asbestos, 1-49 ppm PCBs, Non-RCRA [2.2] Physical State: Various Permissible Waste Codes: N/A (Asbestos) NOTE: Contract unique CLIN descriptionC725,000LB$ - 0$ - 0
PC06PCB Oil-Filled Capacitors/Ballasts/Equipment other than Transformers, >=50 ppm PCBs, Non-RCRA, Certificate of Recycling or Destruction Required. [2.2] Physical State: Various Permissible Waste Codes: N/AC77,000LB$ - 0$ - 0
PC07PCB Oil-Filled Transformers, 0.5-49 ppm PCBs. [2.2]

Physical State: Various

Permissible Waste Codes: N/AC750,000LB$ - 0$ - 0
PC08PCB Oil-Filled Transformers, >=50 ppm PCBs. Certificate of Recycling or Destruction Required. [2.2]

Physical State: Various

Permissible Waste Codes: N/AC711,000LB$ - 0$ - 0
PC09PCB Solids/Debris Contaminated with 0.5-49 ppm Source, i.e., Transformer Carcasses, Drained Equipment, Ballasts, Rags, PPE, Empty Containers, Asphalt, Concrete. No Free Liquids. [2.2]

Physical State: Solid

Permissible Waste Codes: D004-D011 NOTE: Contract unique CLIN descriptionC750,000LB$ - 0$ - 0
PC10PCB Solids/Debris Contaminated with >=50 ppm Source, i.e. Transformer Carcasses, Drained Equipment, Ballasts, Rags, PPE, Empty Containers. No Free Liquids. Certificate of Disposal Required. [2.2]

Physical State: Solid Permissible Waste Codes: N/A C7 36,000 LB $ - 0 $ - 0

CLIN TypeUnit CLIN/Unit of Issue DesignationsSuffixU/M
Containerized0-5 Gal (DM/DF)C1EA
6-15 Gal (DM/DF)C2EA
16-30 Gal (DM/DF)C3EA
31-55 Gal (DM/DF)C4EA
56-95 Gal (DM/DF)C5EA
Cubic Yard Box, Cubic Yard Bag, Tri-Wall, or PalletC6EA
Pounds (Containerized)C7LB
BulkPounds (Bulk) For Loads <10,000 Lbs Net WeightB1LB
Pounds (Bulk) For Loads 10,000-20,000 Lbs Net WeightB2LB
Pounds (Bulk) For Loads 20,000-30,000 Lbs Net WeightB3LB
Pounds (Bulk) For Loads >30,000 Lbs Net WeightB4LB
GallonsB5GL
Cubic Yards for Lightweight Solids/Debris <600 LB/CYB6CY
Miscellaneous Lamps, CylindersEach or Lecture (≤ 3" diameter x 12" height for cylinders)MEEA
Small (≤ 4" diameter x 24" height for cylinders)M1EA
Medium (≤ 12" diameter x 36" height for cylinders)M2EA
Large (≤ 16" diameter x 56" height for cylinders)M3EA

1st Option

Japan PCB Bid Schedule 18 Month 1st Option Period

6300-7990 SPECIAL SERVICES
CLINDescriptionEst. QTYU/MUnit CostTotal
6509MFShipping Maniefests/Documentation [see 3.4]300ea$ - 0$ - 0
6610WPPackaging material disposal service [see 3.1]100ea$ - 0$ - 0
6311AAProvide service to place waste in containers - up to one 5 gal container10ea$ - 0$ - 0
6311BBProvide service to place waste in containers - one non-bulk container greater than 5 gal10ea$ - 0$ - 0
6312C2Provide container, 5 gal, UN 1H1/Y1.8/100 closed top, plastic, new10ea$ - 0$ - 0
6312E2Provide container, 55 gal, 1A1, closed top, steel, reconditioned5ea$ - 0$ - 0
6312F2Provide container, 85 gal UN1H2/X435/S or UN1H2T/Y320/S removable head (dual rated liquid/solid) plastic, new5ea$ - 0$ - 0
7990Overage surcharge for PCB items and containers when nine (9) months have elapsed between the out-of-service date and delivery order removal date [see 3.3]1,000lbs$ - 0$ - 0
Profile Based CLINs
FLAMMABLE/COMBUSTIBLE/IGNITABLE
Base CLINDescriptionSuffixEst. Qty.U/MUnit CostTotal
FL03Flammable Liquids/Solids/Sludges/Debris, i.e. tank sludge, lubricants, paint-related waste, adhesives, rags, filters, PPE, with <50ppm PCBs Physical State: Various Permissible Waste Codes: D001-2, D004-43, Listed Note: contract unique CLIN descriptionC12EA$ - 0$ - 0
C22EA$ - 0$ - 0
C32EA$ - 0$ - 0
C45EA$ - 0$ - 0
0
Base CLINDescriptionSuffixEst. Qty.U/MUnit CostTotal
PC01PCB and PCB/RCRA-Mixed Waste Contaminated with or Containing >=50 ppm Source, i.e., Debris, Sludge, Water, Leaking Capacitors, Fluids other than Transformer Mineral Oil. Certificate of Destruction Required. [2.2] Physical State: Various Permissible Waste Codes: Characteristic, ListedC75,000LB$ - 0$ - 0
PC02PCB Mineral Oil from Transformers, 1-49 ppm PCBs, Non-RCRA [2.2] Physical State: Liquid Permissible Waste Codes: N/AC719,000LB$ - 0$ - 0
PC03PCB Mineral Oil from Transformers, 50-4,000 ppm PCBs. Non-RCRA, Certificate of Recycling or Destruction Required. [2.2]

Physical State: Liquid

Permissible Waste Codes: N/AC71,500LB$ - 0$ - 0
PC04PCB Mineral Oil , Water, Other Fluids, >4,000 ppm PCBs. Certificate of Destruction Required. [2.2] Physical State: Liquid Permissible Waste Codes: Characteristic, ListedC7700LB$ - 0$ - 0
PC05PCB Oil-Filled Capacitors/Equipment other than Transformers, may include cable with asbestos, 1-49 ppm PCBs, Non-RCRA [2.2] Physical State: Various Permissible Waste Codes: N/A (Asbestos) NOTE: Contract unique CLIN descriptionC725,000LB$ - 0$ - 0
PC06PCB Oil-Filled Capacitors/Ballasts/Equipment other than Transformers, >=50 ppm PCBs, Non-RCRA, Certificate of Recycling or Destruction Required. [2.2] Physical State: Various Permissible Waste Codes: N/AC77,000LB$ - 0$ - 0
PC07PCB Oil-Filled Transformers, 0.5-49 ppm PCBs. [2.2]

Physical State: Various

Permissible Waste Codes: N/AC750,000LB$ - 0$ - 0
PC08PCB Oil-Filled Transformers, >=50 ppm PCBs. Certificate of Recycling or Destruction Required. [2.2]

Physical State: Various

Permissible Waste Codes: N/AC711,000LB$ - 0$ - 0
PC09PCB Solids/Debris Contaminated with 0.5-49 ppm Source, i.e., Transformer Carcasses, Drained Equipment, Ballasts, Rags, PPE, Empty Containers, Asphalt, Concrete. No Free Liquids. [2.2]

Physical State: Solid

Permissible Waste Codes: D004-D011 NOTE: Contract unique CLIN descriptionC750,000LB$ - 0$ - 0
PC10PCB Solids/Debris Contaminated with >=50 ppm Source, i.e. Transformer Carcasses, Drained Equipment, Ballasts, Rags, PPE, Empty Containers. No Free Liquids. Certificate of Disposal Required. [2.2]

Physical State: Solid Permissible Waste Codes: N/A C7 36,000 LB $ - 0 $ - 0

CLIN TypeUnit CLIN/Unit of Issue DesignationsSuffixU/M
Containerized0-5 Gal (DM/DF)C1EA
6-15 Gal (DM/DF)C2EA
16-30 Gal (DM/DF)C3EA
31-55 Gal (DM/DF)C4EA
56-95 Gal (DM/DF)C5EA
Cubic Yard Box, Cubic Yard Bag, Tri-Wall, or PalletC6EA
Pounds (Containerized)C7LB
BulkPounds (Bulk) For Loads <10,000 Lbs Net WeightB1LB
Pounds (Bulk) For Loads 10,000-20,000 Lbs Net WeightB2LB
Pounds (Bulk) For Loads 20,000-30,000 Lbs Net WeightB3LB
Pounds (Bulk) For Loads >30,000 Lbs Net WeightB4LB
GallonsB5GL
Cubic Yards for Lightweight Solids/Debris <600 LB/CYB6CY
Miscellaneous Lamps, CylindersEach or Lecture (≤ 3" diameter x 12" height for cylinders)MEEA
Small (≤ 4" diameter x 24" height for cylinders)M1EA
Medium (≤ 12" diameter x 36" height for cylinders)M2EA
Large (≤ 16" diameter x 56" height for cylinders)M3EA

2nd Option

Japan PCB Bid Schedule 18 Month 2nd Option Period

6300-7990 SPECIAL SERVICES
CLINDescriptionEst. QTYU/MUnit CostTotal
6509MFShipping Maniefests/Documentation [see 3.4]300ea$ - 0$ - 0
6610WPPackaging material disposal service [see 3.1]100ea$ - 0$ - 0
6311AAProvide service to place waste in containers - up to one 5 gal container10ea$ - 0$ - 0
6311BBProvide service to place waste in containers - one non-bulk container greater than 5 gal10ea$ - 0$ - 0
6312C2Provide container, 5 gal, UN 1H1/Y1.8/100 closed top, plastic, new10ea$ - 0$ - 0
6312E2Provide container, 55 gal, 1A1, closed top, steel, reconditioned5ea$ - 0$ - 0
6312F2Provide container, 85 gal UN1H2/X435/S or UN1H2T/Y320/S removable head (dual rated liquid/solid) plastic, new5ea$ - 0$ - 0
7990Overage surcharge for PCB items and containers when nine (9) months have elapsed between the out-of-service date and delivery order removal date [see 3.3]1,000lbs$ - 0$ - 0
Profile Based CLINs
FLAMMABLE/COMBUSTIBLE/IGNITABLE
Base CLINDescriptionSuffixEst. Qty.U/MUnit CostTotal
FL03Flammable Liquids/Solids/Sludges/Debris, i.e. tank sludge, lubricants, paint-related waste, adhesives, rags, filters, PPE, with <50ppm PCBs Physical State: Various Permissible Waste Codes: D001-2, D004-43, Listed Note: contract unique CLIN descriptionC12EA$ - 0$ - 0
C22EA$ - 0$ - 0
C32EA$ - 0$ - 0
C45EA$ - 0$ - 0
0
Base CLINDescriptionSuffixEst. Qty.U/MUnit CostTotal
PC01PCB and PCB/RCRA-Mixed Waste Contaminated with or Containing >=50 ppm Source, i.e., Debris, Sludge, Water, Leaking Capacitors, Fluids other than Transformer Mineral Oil. Certificate of Destruction Required. [2.2] Physical State: Various Permissible Waste Codes: Characteristic, ListedC75,000LB$ - 0$ - 0
PC02PCB Mineral Oil from Transformers, 1-49 ppm PCBs, Non-RCRA [2.2] Physical State: Liquid Permissible Waste Codes: N/AC719,000LB$ - 0$ - 0
PC03PCB Mineral Oil from Transformers, 50-4,000 ppm PCBs. Non-RCRA, Certificate of Recycling or Destruction Required. [2.2]

Physical State: Liquid

Permissible Waste Codes: N/AC71,500LB$ - 0$ - 0
PC04PCB Mineral Oil , Water, Other Fluids, >4,000 ppm PCBs. Certificate of Destruction Required. [2.2] Physical State: Liquid Permissible Waste Codes: Characteristic, ListedC7700LB$ - 0$ - 0
PC05PCB Oil-Filled Capacitors/Equipment other than Transformers, may include cable with asbestos, 1-49 ppm PCBs, Non-RCRA [2.2] Physical State: Various Permissible Waste Codes: N/A (Asbestos) NOTE: Contract unique CLIN descriptionC725,000LB$ - 0$ - 0
PC06PCB Oil-Filled Capacitors/Ballasts/Equipment other than Transformers, >=50 ppm PCBs, Non-RCRA, Certificate of Recycling or Destruction Required. [2.2] Physical State: Various Permissible Waste Codes: N/AC77,000LB$ - 0$ - 0
PC07PCB Oil-Filled Transformers, 0.5-49 ppm PCBs. [2.2]

Physical State: Various

Permissible Waste Codes: N/AC750,000LB$ - 0$ - 0
PC08PCB Oil-Filled Transformers, >=50 ppm PCBs. Certificate of Recycling or Destruction Required. [2.2]

Physical State: Various

Permissible Waste Codes: N/AC711,000LB$ - 0$ - 0
PC09PCB Solids/Debris Contaminated with 0.5-49 ppm Source, i.e., Transformer Carcasses, Drained Equipment, Ballasts, Rags, PPE, Empty Containers, Asphalt, Concrete. No Free Liquids. [2.2]

Physical State: Solid

Permissible Waste Codes: D004-D011 NOTE: Contract unique CLIN descriptionC750,000LB$ - 0$ - 0
PC10PCB Solids/Debris Contaminated with >=50 ppm Source, i.e. Transformer Carcasses, Drained Equipment, Ballasts, Rags, PPE, Empty Containers. No Free Liquids. Certificate of Disposal Required. [2.2]

Physical State: Solid Permissible Waste Codes: N/A C7 36,000 LB $ - 0 $ - 0

CLIN TypeUnit CLIN/Unit of Issue DesignationsSuffixU/M
Containerized0-5 Gal (DM/DF)C1EA
6-15 Gal (DM/DF)C2EA
16-30 Gal (DM/DF)C3EA
31-55 Gal (DM/DF)C4EA
56-95 Gal (DM/DF)C5EA
Cubic Yard Box, Cubic Yard Bag, Tri-Wall, or PalletC6EA
Pounds (Containerized)C7LB
BulkPounds (Bulk) For Loads <10,000 Lbs Net WeightB1LB
Pounds (Bulk) For Loads 10,000-20,000 Lbs Net WeightB2LB
Pounds (Bulk) For Loads 20,000-30,000 Lbs Net WeightB3LB
Pounds (Bulk) For Loads >30,000 Lbs Net WeightB4LB
GallonsB5GL
Cubic Yards for Lightweight Solids/Debris <600 LB/CYB6CY
Miscellaneous Lamps, CylindersEach or Lecture (≤ 3" diameter x 12" height for cylinders)MEEA
Small (≤ 4" diameter x 24" height for cylinders)M1EA
Medium (≤ 12" diameter x 36" height for cylinders)M2EA
Large (≤ 16" diameter x 56" height for cylinders)M3EA

File details come from the government source that posted it. Updated .