This is a Statement of Work for the Department of Veterans Affairs Eastern Colorado HealthCare System, Rocky Mountain Regional VA Medical Center, for a firm-fixed contract to deliver one Sonosite ST ultrasound system for Cath/Lab services. The procurement includes seven contract line items (CLINs): the primary ultrasound unit (Sonosite ST or equal), a small basket, steep needle profiling kit, L12-3 transducer, two manuals, a user guide USB, and Sonosite Institute Point-of-Care Ultrasound training. The equipment must meet specific physical specifications including a minimum 21-inch screen, 60-degree tilting capability, four transducer ports, 128GB image storage, 30-minute minimum battery life, and maximum dimensions of 67.5" H x 23.9" W x 43" D weighing no more than 280 pounds.

The ultrasound system must support comprehensive scanning modes including 2D, 3D freehand, navigation software, image fusion, tissue harmonic imaging, M-Mode, and multiple Doppler modes (pulsed wave, continuous wave, velocity color, and power Doppler). Required control interfaces include a physical keyboard, touchscreen monitor, and articulating support arm for flexible viewing. Additional mandatory capabilities include panoramic mode, multi-modality display, image annotation, customizable PACS-compatible forms, patient worklist creation without network connection, needle enhancement, digital calipers, and shear wave/strain-based elastography. The system must include analysis packages for procedural, abdominal, musculoskeletal, small parts, vascular, pelvic, urology, and breast imaging, plus a fusion-targeted biopsy system capable of accepting MRI and ultrasound images with real-time 3D needle tracking. Delivery is required within 30 days of award to Rocky Mountain Regional VA Medical Center in Aurora, Colorado, during Monday-Friday operating hours (0700-1500). The contract includes a five-year manufacturer's warranty, security requirements mandating OEM-supported operating systems, DICOM compatibility, wireless 802.11b/g/n connectivity with FIPS 140-2 compliance, encrypted hard drives, and AGFA PACS compatibility. Vendors must provide two operating and maintenance manuals (electronic and physical) and compiled maintenance schedules in binder format.

View the file

Other files

File Type Posted
VAAR 852 219-76 VA LOS-Certificate of Compliance for Supplies and Products.docx DOCX document
FAR 52 225 2 Buy American Certificate.docx DOCX document
Combine Synopsis Ultrasound.docx DOCX document
36C25926Q0357.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Work Eastern Colorado HealthCare System Rocky Mountain Regional VA Medical Center

1. Purpose:

1.1 The Department of Veterans Affairs, Eastern Colorado HealthCare System, Rocky Mountain Regional Hospital is requesting a Firm-fixed Contract for the delivery of one (1) Sonosite ST ultrasound for Cath/Lab services.

2.0 Nomenclature and Part Number(s):

CLIN
Part Number
Nomenclature
Unit of Measure
Quantity
0001
L31500 or equal
Sonosite ST Ultrasound System or equal
EA
1
0002
P31987 or equal
Small Basket
EA
1
0003
P31199 or equal
Steep Needle Profiling, Sonosite ST or equal
EA
1
0004
L22916 or equal
Transducer L12-3 or equal
EA
1
0005
P27929 or equal
Sonosite Manual or equal
EA
2
0006
P31284 or equal
User Guide USB
EA
1
0007
NA
Sonosite Institute for Point-of-Care Ultrasound or equal
NA
NA

2.1 Salient Characteristics:

1. Unit physical specifications

a. Minimum screen size [in]
21
b. Minimum tilting [degrees]
60
c. Monitor height ranges from floor [in]
57.5-67.5 in
d. Minimum number of transducer ports
4
e. Minimum image storage [days or TB]
128 GB
f. Minimum battery life [min]
30
g. Maximum equipment dimensions (HxWxD) [in]
67.5 x 23.9 x 43
h. Maximum equipment weight [lbs]
280

2. Scanning modes

a. Two-dimensional (2D)

b. Three-dimensional (3D) – freehand

c. Navigation Software

d. Image Fusion Software

e. Tissue Harmonic Imaging

f. M-Mode

g. Simultaneous M-Mode

h. Pulsed Wave Doppler

i. Continuous Wave Doppler

j. Velocity Color Doppler

k. Color Power Doppler

l. Tissue Doppler Imaging

3. Doppler displays

a. Frequency

b. Velocity

c. Power (microvascular/directorial)

d. Duplex

☒ e. Triplex

f. Steering for color Doppler is required to be 3° increments or less

4. Control panel specifications

a. Physical keyboard

b. Touchscreen monitor

c. Keyboard on touchscreen

d. Articulating support arm to allow for vertical and horizontal adjustment of the monitors for viewing from anywhere in the room

5. Additional specifications

a. Panoramic mode

b. Multi-modality display

c. Image annotation

d. One-button image optimization

e. One-button Doppler optimization

f. Programmable protocols

g. Built-in, customizable PACS-compatible form

h. Ability to create patient worklist without order or network connection

i. Specific applications and workflows for all imaging specialties, including interventional guidance

j. Shear wave and strain-based elastography

k. Beam steering

l. Ability to enter standby mode or sleep mode

m. Needle enhancement

n. Image editing – easy video editing and annotation

o. Digital calipers

6. Analysis packages

a. Procedural

b. Abdominal

c. Musculoskeletal Clinical

d. Small Parts

e. Vascular – measurement and analysis of vessels

f. Pelvic

g. Urology

h. Breast

7. Transducers

Description
Qty
Frequency Range [MHz]
a. L22916 - Transducer, L12-3 (RMR/Lindstrom)
2
12 - 3 MHz

8. Advanced features

Fusion-Targeted Biopsy System

a. Capable of accepting MRI (both 1.5T and 3.0T) and ultrasound images from other modalities as input and displaying these images on a screen

b. Tracking and recording of needle movement during biopsy in 3D coordinates in real-time

c. Availability of projected, future needle movement during biopsy in 3D coordinates

d. Image storage for any captured images

2.2 The purchase shall include 5-Year Manufacturer’s Warranty.

3. Security/Connectivity requirements

3.1 OEM-supported operating system

3.2 Latest DICOM print, store, commit, structured report (SR) and modality worklist

3.3 Wireless connectivity to VA network – Compatible with 802.11b/g/n and FIPS 140-2 or FIPS-3 compliant

3.4 Encrypted hard drive

3.5 PACS compatibility – AGFA PACS

4. Delivery:

4.1 Delivery will be made within 30 days of award unless specified differently within the scope of the contract.

4.2 Contractor shall deliver all equipment and supplies to the following address.

Rocky Mountain Regional VA Medical Center (Station 554)
1700 North Wheeling Street
Aurora, CO 80045-7211

4.3 Delivery Hours of Operation: Monday – Friday; 0700hrs – 1500hrs; excluding all Federal Holidays and any other day specifically declared a National Holiday by the President of the United States.

· New Year’s Day

· Dr. Martin Luther King Jr’s Birthday

· Presidents’ Day

· Memorial Day

· Juneteenth

· Independence Day

· Labor Day

· Columbus Day

· Veteran’s Day

· Thanksgiving Day

· Christmas Day

4.4 When one of the above designated legal holidays falls on a Sunday, the following Monday will be observed as a legal holiday. When a legal holiday falls on a Saturday, the preceding Friday is observed as a holiday by US Government Agencies.

4.5 Delivery Markings: Contractor shall deliver items in manufacturer's original sealed containers with manufacturer’s name marked thereon. Deliveries shall be marked with the following information:

· Purchase Order Number

· Contract Number

5. Operation and Maintenance Deliverables:

5.1 Vendor shall include two current operating and maintenance manuals. One electronic and one physical copy.

5.2 Binders and Digital Copies for all equipment

5.3 Deliver compilation of all manufacturers recommended maintenance schedule and operation materials packaged in binder (s) to the POC listed above.

6. Security Requirements:

6.1 Security background checks are not required.

6.2 The Contractor will not have access to VA Desktop computers they will not have access to online resources belonging to the government.

6.3 The Contractor will not have access to protected Patient Health Information (PHI), nor will they have capability of accessing patient information during the services provided to the VA and if removal of equipment from the VA is required; any memory storage device will remain in VA control and will not be removed from VA custody. All research data available for Contractor analysis is de-identified.

6.4 The C&A Requirements do not apply.

6.5 The Security Accreditation Package is not required.

File details come from the government source that posted it. Updated .