SOW Membrane Nitrogen Generator.pdf
PDF 115 KB Posted
- Attached to
- Brand Name Generon Membrane Nitrogen Gas Generator Federal contract opportunity
- Solicitation number
- N0042126Q1049
About this file
This Statement of Work (SOW) details a requirement for a Membrane Nitrogen Gas Generator for the Propulsion Systems Evaluation Facility (PSEF) at the Naval Air Warfare Center Aircraft Division in Patuxent River, Maryland. The technical requirements specify a single unit with precise performance specifications, including a 240 SCFM nitrogen discharge gas flowrate at 96% purity, minimum membrane life of 10 years, and automated purity level control from 96% to 99%. The generator must operate with unfiltered compressed air at pressures between 100-150 psig, housed in a cabinet enclosure measuring 3'-0" Wide x 6'-0" Length x 10' Height, and include features such as pre-filtration equipment, an automated membrane inlet shutdown valve, and a NEMA 4 control panel with local HMI.
The delivery schedule is 12 weeks after contract award, with shipping included to the Naval Air Warfare Center Aircraft Division at 22229 Elmer Road, Building 2360, Patuxent River, MD 20670. The generator must provide continuous, intermittent, or fluctuating flow compatible with downstream pressures between 0 and 150 psig, and include a purity assurance system to divert off-specification nitrogen to a separate port. Additional specifications cover nitrogen discharge pressure, flowrate adjustments, and operational parameters such as compressed air supply conditions and temperature requirements.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SF-30 (0002 Brand Name Generon (1).pdf | ||
| SF-30 (0002 Brand Name Generon.pdf | ||
| Statement of Work (SOW) Membrane Nitrogen Generator revised 10_Feb_ 2026.docx | DOCX document | |
| Updated Statement of Work (SOW).docx | DOCX document | |
| SF-30 Revised SF-18 N0042126Q1049 UPDATED STATEMENT OF WORK SECTION C.pdf | ||
| SF-18 Review.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK
(19 November 20205)
Membrane Nitrogen Gas Generator
BACKGROUND
The Propulsion Systems Evaluation Facility (PSEF), Patuxent River, MD has a requirement for a membrane nitrogen generator to convert dry, unfiltered, compressed air to nitrogen gas to supply a test rig.
TECHNICAL REQUIREMENTS
CLIN 0001: Membrane Nitrogen Generator per specifications below: Quantity - 1
a) Membrane type nitrogen gas generator with minimum membrane life of 10 years at 100% duty cycle.
b) Nitrogen discharge gas flowrate of 240 SCFM (Standard Cubic Feet per Minute, referenced to 68°F at 14.5 psi) at 96% (by volume) purity level with dry, unfiltered compressed air supply of 115 psig at nominal 75°F.
c) Minimum nitrogen discharge pressure of 90 psig for a 115 psig air supply pressure.
d) Fully automated control of purity levels from 96% to 99% based on user adjustable setpoint input.
e) Minimum flowrate of 100 SCFM at 99 % purity level for inlet pressure of 115 psig.
f) Flowrate adjusts automatically to meet demand.
g) Nitrogen gas discharge flow compatible with continuous, intermittent, or fluctuating flow demand and variable downstream pressure between 0 and 150 psig.
h) Operates with unfiltered compressed air at compressed air supply pressures between 100 psig and 150 psig at pressure dewpoint of 38°F or below.
i) Nitrogen Generator is housed in a cabinet enclosure with maximum overall dimensions of
3’-0" Wide x 6’-0" Length x 10’ Height
j) Includes pre-filtration equipment internal to cabinet enclosure to handle moisture and particulates
k) Includes an automated membrane inlet shutdown valve to protect membrane from moisture and particulate contamination.
l) Includes Output purity level indication
m) Cabinet includes forklift slots / lifting eyes
n) Includes purity assurance system with valve to divert Off spec (below setpoint purity level) nitrogen to Off spec port for customer routing to atmospheric vent
o) NEMA 4 control panel with local HMI (Human Machine Interface) for operator interface
p) Shipping to 20670 included, FOB Destination
DELIVERY SCHEDULE
Delivery 12 weeks after contract award.
LOCATION FOR SHIPMENTS:
Naval Air Warfare Center Aircraft Division Propulsion Systems Evaluation Facility 22229 Elmer Road, Bldg. 2360 Patuxent River, MD 20670