SOW Attach 8_Instrumentation Drawings - Split HP-3 DDC Schematic.pdf
PDF 87 KB Posted
- Attached to
- Bldg 77H Split System HP-3 Replacement, NSWCPD Federal contract opportunity
- Solicitation number
- N6449821Q0195
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| N64498-21-Q-0195 Amendment 0001.pdf | ||
| SOW Attach 4_Mobile Equipment Check List.pdf | ||
| SOW Attach 6_NSWCPD ENTRY SCREENING ASSESSMENT 26 APR 2021 Rev 10.pdf | ||
| SOW Attach 1_SiteMap PNBC.pdf | ||
| SOW Attach 2_Contractor Production Report Form.doc | DOC document | |
| SOW Attach 3_Contractor Lift Plan Form.pdf | ||
| N64498-21-Q-0195.pdf | ||
| SOW Attach 5_AHA Form.docx | DOCX document | |
| SOW Attach 7_Photographs - B-77H Split System HP-3 Replacement.docx | DOCX document | |
| SOW Attach 9_Sketch 1 -- Bldg 77H Split System HP-3.pdf | ||
| Attach 10_ Construction Cost Breakdown.xlsx | XLSX spreadsheet |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AutoCAD SHX Text
AI:2
AutoCAD SHX Text
AI:1
AutoCAD SHX Text Building 77H Split 3 DDC Schematic
AutoCAD SHX Text
GND
AutoCAD SHX Text Net -
AutoCAD SHX Text
GND
AutoCAD SHX Text
SE6166
AutoCAD SHX Text
24 VAC
AutoCAD SHX Text Net +
AutoCAD SHX Text Shield
AutoCAD SHX Text
115 VAC
AutoCAD SHX Text
CB
AutoCAD SHX Text
50 VA
AutoCAD SHX Text
1.6 Amp
AutoCAD SHX Text
XFMR
AutoCAD SHX Text F1
AutoCAD SHX Text TS2 - Supply Air Temp, 10K@77 F
AutoCAD SHX Text
DO:6
AutoCAD SHX Text
DO:5
AutoCAD SHX Text
AI:3
AutoCAD SHX Text
AI:4
AutoCAD SHX Text
AI:5
AutoCAD SHX Text
AI:7
AutoCAD SHX Text
AI:6
AutoCAD SHX Text
AI:8
AutoCAD SHX Text
AI:9
AutoCAD SHX Text
AI:10
AutoCAD SHX Text
DO:4
AutoCAD SHX Text
DO:3
AutoCAD SHX Text
DO:2
AutoCAD SHX Text
DO:1
AutoCAD SHX Text Not Used
AutoCAD SHX Text
GND
AutoCAD SHX Text
GND
AutoCAD SHX Text SR1,1 SA Smoke Detector
AutoCAD SHX Text
GND
AutoCAD SHX Text
GND
AutoCAD SHX Text
ALC
AutoCAD SHX Text Control Module
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GND
AutoCAD SHX Text
+24 VDC
AutoCAD SHX Text CS1 - Compressor Status 1 - 0-10 VDC
AutoCAD SHX Text
GND
AutoCAD SHX Text
AO:4
AutoCAD SHX Text
AO:3
AutoCAD SHX Text
AO:2
AutoCAD SHX Text
AO:1
AutoCAD SHX Text
GND
AutoCAD SHX Text
AutoCAD SHX Text
GND
AutoCAD SHX Text
AutoCAD SHX Text
GND
AutoCAD SHX Text
AutoCAD SHX Text
GND
AutoCAD SHX Text
AutoCAD SHX Text Y2-Comp Stage 2
AutoCAD SHX Text Y1-Comp Stage 1
AutoCAD SHX Text G-Supply Fan S/S
AutoCAD SHX Text Robert Smargiassi March 10, 2021
AutoCAD SHX Text Rnet-
AutoCAD SHX Text Rnet+
AutoCAD SHX Text
+12VDC
AutoCAD SHX Text DP1 - Supply Fan DP Switch
AutoCAD SHX Text TS1 - Zone Temp 1, 10K@77 F
AutoCAD SHX Text HS1 - Return Air Humidity
AutoCAD SHX Text TS3 - Return Air Temp, 10K@77 F
AutoCAD SHX Text CS2 - Compressor Status 1 - 0-10 VDC
AutoCAD SHX Text G
AutoCAD SHX Text H1
AutoCAD SHX Text H2
AutoCAD SHX Text TS1A - Zone Temp 2, 10K@77 F
AutoCAD SHX Text Mixed Air Temperature
AutoCAD SHX Text
AI:11
AutoCAD SHX Text
AI:12
AutoCAD SHX Text
GND
AutoCAD SHX Text
AI:13
AutoCAD SHX Text
AI:14
AutoCAD SHX Text
GND
AutoCAD SHX Text Electric Heat 2 Status
AutoCAD SHX Text Drip Pan
AutoCAD SHX Text Electric Heat 1 Status
AutoCAD SHX Text Y1
AutoCAD SHX Text Y2
AutoCAD SHX Text H2-Heat Stage 2
AutoCAD SHX Text H1-Heat Stage 1
AutoCAD SHX Text
AI:15
AutoCAD SHX Text
AI:16
AutoCAD SHX Text
GND
AutoCAD SHX Text Spare
AutoCAD SHX Text Spare
AutoCAD SHX Text Spare
AutoCAD SHX Text Economizer
AutoCAD SHX Text
AO:6
AutoCAD SHX Text
AO:5
AutoCAD SHX Text
GND
AutoCAD SHX Text
AutoCAD SHX Text
GND
AutoCAD SHX Text
AutoCAD SHX Text Notes: 1. The contractor shall leave about 6 feet of cable in the DDC panel for each input/output. 2. The cable shall be marked. 3. The Government will make the final termination.
neal.j.moran Text Box Building 77H Split System HP-3 Replacement SOW Attachment 8 Instrumentation Drawings -- DDC Schematic Sheet 1 of 1
| Sheets and Views |
| B-77H Split-3-Model |