This file is a Hazardous Materials Survey Report documenting comprehensive asbestos-containing materials (ACM) and lead-based paint (LBP) sampling conducted at Building 4047, Kadena Air Base, Okinawa, Japan under Contract No. W912HV21P0027. The survey was prepared by Environmental Science Corporation (ESC) on March 6, 2023, for the 718th Civil Engineer Squadron at Kadena Air Base. The report includes detailed photo records of sampling locations, chain-of-custody documentation, laboratory certifications, and analysis results for bulk samples collected from suspected hazardous materials throughout the building.

The survey results indicate that of 27 asbestos samples collected, 3 samples tested positive for ACM, specifically identifying 2% chrysotile in gray mastic found in vinyl cove base materials from three different rooms (H2 samples from Rooms 104, 101, and 102). All 14 lead-based paint samples tested negative for LBP according to EPA and Japan Environmental Governing Standards (JEGS) criteria defining LBP as paint containing ≥0.5% lead by weight. Samples were analyzed using polarized light microscopy (PLM) with 1000-point counting for asbestos detection and EPA Method 3050B/7000B Atomic Absorption Spectroscopy for lead analysis. The report notes that the GOJ regulatory limit for lead as specially-controlled industrial waste is 0.3 mg/L, and recommends TCLP testing on any lead-containing paint materials for proper disposal classification purposes.

View the file

Other files

File Type Posted
Sources Sought Attachment W912HV26Z0012 VMS Intermediate DRAWINGS DRAFT_Part6.pdf PDF
Sources Sought Attachment W912HV26Z0012 VMS Intermediate DRAWINGS DRAFT_Part12.pdf PDF
Sources Sought Attachment W912HV26Z0012 VMS Intermediate DRAWINGS DRAFT_Part11.pdf PDF
Sources Sought Attachment W912HV26Z0012 VMS Intermediate DRAWINGS DRAFT_Part10.pdf PDF
Sources Sought Attachment W912HV26Z0012 VMS Intermediate DRAWINGS DRAFT_Part8.pdf PDF
Sources Sought Attachment W912HV26Z0012 VMS Intermediate DRAWINGS DRAFT_Part5.pdf PDF
Sources Sought Attachment W912HV26Z0012 VMS Intermediate DRAWINGS DRAFT_Part2.pdf PDF
Sources Sought Notice W912HV26Z0012.pdf PDF
Sources Sought Attachment W912HV26Z0012 VMS Intermediate SPECIFICATIONS DRAFT_Part1.pdf PDF
Sources Sought Attachment W912HV26Z0012 VMS Intermediate DRAWINGS DRAFT_Part9.pdf PDF
Sources Sought Attachment W912HV26Z0012 VMS Intermediate DRAWINGS DRAFT_Part1.pdf PDF
Sources Sought Attachment W912HV26Z0012 VMS Intermediate SPECIFICATIONS DRAFT_Part2.pdf PDF
Sources Sought Attachment W912HV26Z0012 VMS Intermediate DRAWINGS DRAFT_Part7.pdf PDF
Sources Sought Attachment W912HV26Z0012 VMS Intermediate DRAWINGS DRAFT_Part4.pdf PDF
Sources Sought Attachment W912HV26Z0012 VMS Intermediate DRAWINGS DRAFT_Part3.pdf PDF
W912HV26Z0012 Market Survey Questions.docx DOCX document
Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Photo Record Sheet

Asbestos Sampling Kadena Air Base, Bldg.4046

KAB-4046-A7 KAB-4046-A8

KAB-4046-A9 KAB-4046-A10

KAB-4046-A11 KAB-4046-A12

DRAFT

KAB-4046-A13 KAB-4046-A14

KAB-4046-A15 KAB-4046-A16

KAB-4046-A17 KAB-4046-A18

KAB-4046-A19 KAB-4046-A20

KAB-4046-A21 KAB-4046-A22

KAB-4046-A23 KAB-4046-A24

KAB-4046-A25 KAB-4046-A26

KAB-4046-A27 KAB-4046-A28

Intentionally Left Blank Intentionally Left Blank

LEAD BASED PAINT SAMPLING PHOTOS

FY21 KAB Comprehensive ACM & LBP Surveys, Kadena Air Base, Okinawa, Japan

HazMat Survey

Bldg.4046

Lead Based Paint Sampling

KAB-4046-L1 KAB-4046-L2

KAB-4046-L3 KAB-4046-L4

KAB-4046-L5 KAB-4046-L6

KAB-4046-L7 KAB-4046-L8

KAB-4046-L9 KAB-4046-L10

KAB-4046-L11 KAB-4046-L12

KAB-4046-L13 KAB-4046-L14

Contract No. W912HV21P0027

FY21 Comprehensive ACM & LBP Surveys

Kadena Air Base, Okinawa, Japan

Building 4047

Date: 6 March 2023

Prepared for: Kadena Air Base 718th CES/CENM

Prepared by: Environmental Science Corporation (ESC)

DRAFT

chemi テキストボックス NOTE: The following report has been excerpted from the original version to provide the information pertinent to the execution of this project.

i

CONTENTS

ACRONYMS AND ABBREVIATIONS ...................................................................................... ii

1.0 SUMMARY

2.0 ASBESTOS SAMPLING SUMMARY

2.1 ASBESTOS SAMPLING METHODS/ANALYSIS

3.0 LEAD BASED PAINT SAMPLING SUMMARY

3.1 LBP PAINT AS A GOJ SPECIALLY-CONTROLLED INDUSTRIAL

WASTE

3.2 PAINT WITH LEAD

4.0 REFERENCES

TABLES

TABLE 1 SUMMARY TABLE OF ASBESTOS AND LEAD PAINT SAMPLING

APPENDICES

A ASBESTOS / LEAD PAINT SAMPLING LOCATIONS

B ACM SAMPLING CHAINS-OF-CUSTODY & LABORATORY REPORTS

C LBP SAMPLING CHAINS-OF-CUSTODY & LABORATORY REPORTS

D PHOTOGRAPHIC RECORDS OF BULK SAMPLING

E BUILDING INSPECTOR & LABORATORY CERTIFICATIONS

W912HV21P0027 KAB Comprehensive 1

ACM & LBP Surveys B4047

1.0 SUMMARY

Environmental Science Corporation (ESC) conducted a hazardous material inspection at

Building 4047, KAB, Okinawa, Japan. For materials suspected as possible Asbestos Containing

Materials (ACM) and Lead-Based Paint (LBP), bulk sampling was conducted, and samples were sent for subsequent analysis at an accredited analytical laboratory.

The following tasks were conducted as part of the Hazardous Materials Survey:

• Evaluate Government-provided records for validity, conduct on-site sampling and analysis of materials/surfaces where Government-provided records were invalid, conduct new sampling and analysis for areas/surfaces where no records existed, report the evaluation results and new sampling laboratory analysis results in separate summary tables for Asbestos and Lead-Based Paint.

Summary data of all suspect asbestos and lead based paint samples collected from Government provided past records and/or within this survey are located in Table 1 below.

2.0 ASBESTOS SAMPLING SUMMARY

Materials assumed, reported, or confirmed to be ACM was found at the site during this survey investigation. Out of twenty-seven (27) total asbestos samples collected for this survey, three (3) samples were determined to be ACM.

The following additional caveats apply to this supplementary hazardous materials survey for

ACM materials:

• Per the Japan Environmental Governing Standards (JEGS), any polarized light microscopy (PLM) sample result of “trace” is assumed to be > 0.1% asbestos and therefore ACM. For any “trace” sample re-analyzed using 1000-point counting and found to contain less than 0.1% asbestos, the associated homogenous area is considered non-ACM, as long as all other samples of that homogenous area are also less than 0.1% asbestos.

• The highest analytical result from all samples representative of each homogeneous area is used to recommend management of that material as a whole.

• Although not observed at the site during this survey, transite piping, used for older underground sewer and storm drain pipelines, shall be presumed ACM if encountered, unless verified non-ACM by a certified asbestos building inspector.

• Past Government provided ND records analyzed under a 1% laboratory Limit of

Detection (LOD) shall also be treated as an invalid record per JEGS 2022 definition of

ACM.

W912HV21P0027 KAB Comprehensive 2

2.1 ASBESTOS SAMPLING METHODS/ANALYSIS

JEGS defines ACM as any material containing more than 0.1 percent asbestos by weight. All samples were provided to the laboratory accompanied with a copy of paragraph 5.8 from JEGS

2022 as analysis and reporting instructions. The laboratory was instructed to conduct 1000-point counting for all asbestos trace detections. Laboratory result reporting complies with the JEGS criteria.

3.0 LEAD BASED PAINT SAMPLING SUMMARY

The US Environmental Protection Agency (EPA) and JEGS define LBP as paint that contains equal to or greater than 0.5 percent lead by weight. Out of fourteen (14) total paint chip samples collected for this survey, no paint samples were determined to be lead-based paint.

Paint chip samples were collected in accordance with ASTM E1729-05, Standard Practice for

Field Collection of Dried Paint Samples for Subsequent Lead Determination (ASTM, 2005).

The samples were delivered to SGS Forensic Laboratories, Carson, CA under chain of custody for analysis by EPA Method 3050B/7000B, Atomic Absorption Spectroscopy (EPA, 1996).

Laboratory reports are included in Appendix C. Sample locations are shown in Appendix A.

3.1 LBP PAINT AS A GOJ SPECIALLY-CONTROLLED INDUSTRIAL WASTE

It should be noted that GOJ regulatory limit for lead as a specially-controlled industrial waste is

0.3 milligrams per liter (mg/L) for waste sludge, acid, and alkali, as determined by toxicity characteristic leaching procedure (TCLP) laboratory analysis. Although TCLP testing was not part of the scope of this survey, it is recommended that TCLP analysis be performed on LCP-positive materials (particularly for those materials of high surface area) to determine whether the paint in question should be classified as a specially controlled industrial waste for disposal purposes.

3.2 PAINT WITH LEAD

Paint with lead (PWL) can be categorized as lead based paint (LBP) or lead containing paint

(LCP). LBP is defined as paint or other surface coatings that contain lead equal to or greater than one milligram per square centimeter or more than 0.5 percent by weight. Lead-containing paint is paint containing detectable concentrations of lead, but not at sufficient concentration to be classified as LBP. The JEGS define lead containing as paint or other similar surface coating materials containing lead or lead compounds in which the lead content (calculated as lead material) is more than 0.009 percent by weight of the total nonvolatile content of the paint or the weight of the dried paint film (USFJ, 2022).

W912HV21P0027 KAB Comprehensive 4

Table 1 Summary Table of Asbestos and Lead Paint Sampling

HOMOGENEOUS MATERIAL OR SURFACE ANALYSIS RECORD DATA

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

BLDG

NUMBER

ROOM OR

FUNCTIONAL

AREA

HOMOGENEOUS

/SURFACE

NUMBER

MATERIAL NAME

/APPLICATION

DESCRIPTION

(Size, color, other)

FR

IA

B

LE

A C

C

ES

S

CONDITION HA

QTY

GOV

T

C T R

LAB/

SAMPLE ID

NO.

CTR COC SAMPLE

ID NO.

LAB ANALYSIS DATE RESULT VALIDITY

DETERMINATION

NOTES / INVALID OR

UNKNOWN REASONING

ASBESTOS SAMPLES

4047 104 H1 Concrete floor coating Gray N Y Good

SM

Y 51551796 KAB-4047-A1 2022-09-16 ND Valid

4047 104 H2 Vinyl cove base

10cm gray w/white mastic N Y Good

LM

Y 51551797 KAB-4047-A2 2022-09-16

2%/Chr in

Grey mastic

Valid Positive

4047 104 H3 Gypsum board wall Off-white, smooth N Y Good

SM

Y 51551798 KAB-4047-A3 2022-09-16 ND Valid

4047 104 H4 Concrete wall coating Off-white, smooth N Y Good

Y 51551799 KAB-4047-A4 2022-09-16 ND Valid

4047 104 H5 Floor joint sealant Gray mastic N Y Good

LM

Y 51551800 KAB-4047-A5 2022-09-16 ND Valid

4047 104 H6 Door joint sealant White mastic N Y Good

Y 51551801 KAB-4047-A6 2022-09-16 ND Valid

4047 101 H1 Concrete floor coating Gray N Y Good

Y 51551802 KAB-4047-A7 2022-09-16 ND Valid

4047 101 H5 Floor joint sealant Gray mastic N Y Good

Y 51551803 KAB-4047-A8 2022-09-16 ND Valid

4047 101 H2 Vinyl cove base

10cm gray w/white mastic N Y Good

LM

Y 51551804 KAB-4047-A9 2022-09-16

2%/Chr in

Grey mastic

Valid Positive

4047 101 H3 Gypsum board wall Off-white, smooth N Y Good

Y 51551805 KAB-4047-A10 2022-09-16 ND Valid

4047 101 H6 Concrete block wall coating Off-white, smooth N Y Good

Y 51551806 KAB-4047-A11 2022-09-16 ND Valid

4047 102 H1 coating Gray N Y Good

Y 51551807 KAB-4047-A12 2022-09-16 ND Valid

4047 102 H2 Vinyl cove base

10cm gray w/white mastic N Y Good

LM

Y 51551808 KAB-4047-A13 2022-09-16

2%/Chr in

Grey mastic

Valid Positive

4047 102 H3 Gypsum board wall Off-white, smooth N Y Good

SM

Y 51551809 KAB-4047-A14 2022-09-16 ND Valid

4047 102 H5 Floor joint sealant Gray mastic N Y Good

LM

Y 51551810 KAB-4047-A15 2022-09-16 ND Valid

4047 Toilet H7 Ceramic wall tiles 10x10 pale purple tile w/gray grout N Y Good

SM

Y 51551811 KAB-4047-A16 2022-09-16 ND Valid

4047 Toilet H8 Ceramic floor tile 10x10 beige tile w/gray grout N Y Good

SM

Y 51551812 KAB-4047-A17 2022-09-16 ND Valid

4047 Toilet H9 Sink joint sealant White mastic N Y Good

LM

Y 51551813 KAB-4047-A18 2022-09-16 ND Valid

4047 Toilet H4 Concrete wall coating Off-white, smooth N Y Good

SM

Y 51551814 KAB-4047-A19 2022-09-16 ND Valid

4047 Exterior H10 Floor joint sealant Gray mastic N Y Good

LM

Y 51551815 KAB-4047-A20 2022-09-16 ND Valid

4047 Exterior H11 Concrete wall coating Off-white, textured N Y Good

SM

Y 51551816 KAB-4047-A21 2022-09-16 ND Valid

4047 Exterior H12 Wall joint sealant White mastic N Y Good

LM

Y 51551817 KAB-4047-A22 2022-09-16 ND Valid

W912HV21P0027 KAB Comprehensive 5

HOMOGENEOUS MATERIAL OR SURFACE ANALYSIS RECORD DATA

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

BLDG

NUMBER

ROOM OR

FUNCTIONAL

AREA

HOMOGENEOUS

/SURFACE

NUMBER

MATERIAL NAME

/APPLICATION

DESCRIPTION

(Size, color, other)

FR

IA

B

LE

A C

C

ES

S

CONDITION HA

QTY

GOV

T

C T R

LAB/

SAMPLE ID

NO.

CTR COC SAMPLE

ID NO.

LAB ANALYSIS DATE RESULT VALIDITY

DETERMINATION

NOTES / INVALID OR

UNKNOWN REASONING

4047 Exterior H11 Concrete wall coating Off-white, textured N Y Good

SM

Y 51551818 KAB-4047-A23 2022-09-16 ND Valid

4047 Exterior H12 Wall joint sealant White mastic N Y Good

LM

Y 51551819 KAB-4047-A24 2022-09-16 ND Valid

4047 Exterior H11 Concrete wall coating Off-white, textured N Y Good

SM

Y 51551820 KAB-4047-A25 2022-09-16 ND Valid

4047 Exterior H12 Wall joint sealant White mastic N Y Good

LM

Y 51551821 KAB-4047-A26 2022-09-16 ND Valid

4047 Exterior H13 Concrete wall base coating Gray painted orange N Y Good

SM

Y 51551822 KAB-4047-A27 2022-09-16 ND Valid

LEAD PAINT SAMPLES

4047 104 S1 Gypsum board wall Off-white Y Used

Y LM220474 KAB-4047-L1 2022-06-22 <0.007 Valid

4047 104 S2 Metal door frame Light brown Y Used

Y LM220475 KAB-4047-L2 2022-06-22 0.021 Valid

4047 104 S1 Gypsum board wall Off-white Y Used Y LM220476 KAB-4047-L3 2022-06-22 0.007 Valid

4047 104 S3 Metal pipe Red N Used

Y LM220477 KAB-4047-L4 2022-06-22 <0.02 Valid

4047 104 S4 Metal pipe Off-white N Used

Y LM220478 KAB-4047-L5 2022-06-22 <0.009 Valid

4047 104 S5 coating Red Y Used

Y LM220479 KAB-4047-L6 2022-06-22 <0.02 Valid

4047 102 S1 Gypsum board wall Off-white Y Used Y LM220480 KAB-4047-L7 2022-06-22 <0.007 Valid

4047 Exterior S6 Telephone box Yellow Y Used

Y LM220481 KAB-4047-L8 2022-06-22 <0.007 Valid

4047 Exterior S7 Concrete wall Off-white Y Used

Y LM220482 KAB-4047-L9 2022-06-22 0.006 Valid

4047 Exterior S8 Metal pipe Red Y Used

Y LM220483 KAB-4047-L10 2022-06-22 <0.02 Valid

4047 Exterior S9 Metal flange Light blue Y Used

Y LM220484 KAB-4047-L11 2022-06-22 <0.007 Valid

Y LM220485 KAB-4047-L12 2022-06-22 <0.006 Valid

Y LM220486 KAB-4047-L13 2022-06-22 <0.007 Valid

4047 Exterior S10 Metal pipe Off-white Y Used

Y LM220487 KAB-4047-L14 2022-06-22 0.042 Valid

Notes;

The quantities provided in this table represents rough order quantities for the purpose to aid in identifying the homogeneous material identified by the CBI at the time of the survey. This estimate should not be utilized as a basis to develop an estimate for the purpose of formulating a bid for any future work involving all or part of such material.

RED HIGHLIGHT – Asbestos Positive

BLUE HIGHLIGHT – Lead Based Paint Positive

GREEN HIGHLIGHT – Unknown, Trace result with Insufficient Material for Additional Analysis

W912HV21P0027 KAB Comprehensive 6

4.0 REFERENCES

40 CFR Part 745, Lead-Based Paint Poisoning Prevention in Certain Residential Structures.

ASTM, 2005. Standard Practice for Field Collection of Dried Paint Samples for Subsequent

Lead Determination.

Government of Japan, 2001. Japan Waste Management and Public Cleansing Law of 1970, updated 2001.

United States Code 40 CFR Part 745. Lead-Based Paint Poisoning Prevention in Certain

Residential Structures.

US EPA, 1996. Method 3050B/Method No. 7420, Atomic Absorption Spectroscopy.

US EPA, 1993. Method for the Determination of Asbestos in Bulk Building Materials

USFJ, 2022. Japan Environmental Governing Standards (JEGS). April 2022.

APPENDIX A

ASBESTOS / LEAD PAINT SAMPLING LOCATIONS

FY21 KAB COMPREHENSIVE ACM & LBP SURVEYS

KADENA AIR BASE, OKINAWA, JAPAN

BLDG NO:

SAMPLING DATE·

ASBESTOS SAMPLES

A1 A2 A3

A4

A5

A7

A6

A8 A9 A10

A11

A12 A13 A14

A15

A16 A17

A18 A19

A20 A21 A22

A23 A24

A25 A26

A27 L2 L1

L3

L4 L5

L6

L7

L8

L9

L10 L11

L12

L13

L14

APPENDIX B

ACM SAMPLING CHAINS-OF-CUSTODY & LABORATORY REPORTS

Final Report

(EPA Method 40CFR, Part 763, Appendix E to Subpart E and EPA 600/R-93-116, Visual Area Estimation) Bulk Asbestos Analysis

NVLAP Lab Code: 101459-1 L1232Client ID:Environmental Science Corporation B333640Report Number:Sean Dudley

Date Received:Itsuro Building 4F 09/16/22Date Analyzed:3-7-2 Kanda-Nishikicho 09/16/22Date Printed:Chiyoda-ku, Tokyo, JP 101-0054

First Reported:

L1232-1ESC.7315; Kadena Air Base, Okinawa, Japan; Bldg. 4047 SGSFL Job ID:Job ID/Site:

Date(s) Collected: 04/20/2022 27Total Samples Submitted:

Total Samples Analyzed: 27

05/26/22

09/16/22

Sample ID Lab Number Asbestos

Type Percent in

Layer Asbestos AsbestosPercent in Percent in

Type TypeLayer Layer

KAB-4047-A1 51551796

Layer: Grey Cementitious Material ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

KAB-4047-A2 51551797

Layer: Grey Non-Fibrous Material ND Layer: Grey Mastic Chrysotile 2 % Layer: Paint ND Layer: White Joint Compound ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

KAB-4047-A3 51551798

Layer: White Drywall ND Layer: White Skimcoat/Joint Compound ND Layer: Paint ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (10 %) Fibrous Glass (Trace)

KAB-4047-A4 51551799

Layer: Grey Cementitious Material ND Layer: Paint ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

KAB-4047-A5 51551800

Layer: Grey Non-Fibrous Material ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

KAB-4047-A6 51551801

Layer: Off-White Non-Fibrous Material ND Layer: Paint ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

20535 South Belshaw Avenue, Carson, CA 90746 / Telephone: (310) 763-2374 (888) 813-9417 / Fax: (310) 763-4450

Report Number: B333640 Date Printed: 09/16/22Client Name: Environmental Science Corporation

Sample ID Lab Number Asbestos

Type Percent in

Layer Asbestos AsbestosPercent in Percent in

Type TypeLayer Layer

KAB-4047-A7 51551802

Layer: Grey Cementitious Material ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

KAB-4047-A8 51551803

Layer: Grey Non-Fibrous Material ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

KAB-4047-A9 51551804

Layer: Grey Non-Fibrous Material ND Layer: Grey Mastic Chrysotile 2 % Layer: Paint ND Layer: White Drywall ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

KAB-4047-A10 51551805

Layer: White Drywall ND Layer: Paint ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (20 %)

KAB-4047-A11 51551806

Layer: Grey Cementitious Material ND Layer: Paint ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

KAB-4047-A12 51551807

Layer: Grey Cementitious Material ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

KAB-4047-A13 51551808

Layer: Grey Non-Fibrous Material ND Layer: Grey Mastic Chrysotile 2 % Layer: Paint ND Layer: White Drywall ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

KAB-4047-A14 51551809

Layer: White Drywall ND Layer: Paint ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (20 %) Fibrous Glass (2 %)

20535 South Belshaw Avenue, Carson, CA 90746 / Telephone: (310) 763-2374 (888) 813-9417 / Fax: (310) 763-4450

Sample ID Lab Number Asbestos

Type Percent in

Layer Asbestos AsbestosPercent in Percent in

Type TypeLayer Layer

KAB-4047-A15 51551810

Layer: Grey Non-Fibrous Material ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

KAB-4047-A16 51551811

Layer: Grey Ceramic Tile ND Layer: Grey Grout ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

KAB-4047-A17 51551812

Layer: Grey Cementitious Material ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

KAB-4047-A18 51551813

Layer: Off-White Non-Fibrous Material ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

KAB-4047-A19 51551814

Layer: Grey Cementitious Material ND Layer: Paint ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

KAB-4047-A20 51551815

Layer: Grey Non-Fibrous Material ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

KAB-4047-A21 51551816

Layer: Grey Cementitious Material ND Layer: Paint ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

KAB-4047-A22 51551817

Layer: Off-White Non-Fibrous Material w/ ND Layer: Paint ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

KAB-4047-A23 51551818

Layer: Grey Cementitious Material ND Layer: Paint ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

20535 South Belshaw Avenue, Carson, CA 90746 / Telephone: (310) 763-2374 (888) 813-9417 / Fax: (310) 763-4450

Sample ID Lab Number Asbestos

Type Percent in

Layer Asbestos AsbestosPercent in Percent in

Type TypeLayer Layer

KAB-4047-A24 51551819

Layer: White Non-Fibrous Material w/ Debris ND Layer: Paint ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

KAB-4047-A25 51551820

Layer: Grey Cementitious Material ND Layer: White Non-Fibrous Material ND Layer: Paint ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

KAB-4047-A26 51551821

Layer: White Non-Fibrous Material w/ Debris ND Layer: Paint ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

KAB-4047-A27 51551822

Layer: Grey Cementitious Material ND Total Composite Values of Non-Asbestos Fibrous Components:

Cellulose (Trace)

Analytical results and reports are generated by SGS Forensic Laboratories (SGSFL) at the request of and for the exclusive use of the person or entity (client) named on such report.

Results, reports or copies of same will not be released by SGSFL to any third party without prior written request from client. This report applies only to the sample(s) tested.

Supporting laboratory documentation is available upon request. This report must not be reproduced except in full, unless approved by SGSFL. The client is solely responsiblefor the use and interpretation of test results and reports requested from SGSFL. SGSFL is not able to assess the degree of hazard resulting from materials analyzed. SGS Forensic Laboratories reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. All samples were received in acceptable condition unless otherwise noted.

Note: Limit of Quantification ('LOQ') = 1%. 'Trace' denotes the presence of asbestos below the LOQ. 'ND' = 'None Detected'.

Tiffani Ludd, Laboratory Supervisor, Carson Laboratory

20535 South Belshaw Avenue, Carson, CA 90746 / Telephone: (310) 763-2374 (888) 813-9417 / Fax: (310) 763-4450

APPENDIX C

LBP SAMPLING CHAIN OF CUSTODY & LABORATORY REPORTS

Metals Analysis of Paints Client ID:

Report Number:

Date Received:

M242132

Job ID / Site: ESC.7315; KAB Comprehensive Hazmat, Kadena Air Base, Okinawa, Japan, Bldg. 4047

Environmental Science Corporation

3-7-2 Kanda-Nishikicho

L1232

SGSFL Job ID:

Date Analyzed:

L1232-1

Sean Dudley

Chiyoda-ku, Tokyo, JP 101-0054

Itsuro Building 4F

Date Printed: 06/22/22 06/22/22

First Reported: 06/22/22

05/26/22

Final Report

(AIHA-LAP, LLC Accreditation, Lab ID #101762)

Date(s) Collected: 04/20/22 Total Samples Submitted:

Total Samples Analyzed:

Sample Number Lab Number Result Result Reporting Method

Analyte Units Limit* Reference

EPA 3050B/7000B< 0.007PbKAB-4047-L1 LM220474 wt% 0.007

EPA 3050B/7000B0.021PbKAB-4047-L2 LM220475 wt% 0.008

EPA 3050B/7000B0.007PbKAB-4047-L3 LM220476 wt% 0.006

EPA 3050B/7000B< 0.02PbKAB-4047-L4 LM220477 wt% 0.02

EPA 3050B/7000B< 0.009PbKAB-4047-L5 LM220478 wt% 0.009

EPA 3050B/7000B< 0.02PbKAB-4047-L6 LM220479 wt% 0.02

EPA 3050B/7000B< 0.007PbKAB-4047-L7 LM220480 wt% 0.007

EPA 3050B/7000B< 0.007PbKAB-4047-L8 LM220481 wt% 0.007

EPA 3050B/7000B0.006PbKAB-4047-L9 LM220482 wt% 0.006

EPA 3050B/7000B< 0.02PbKAB-4047-L10 LM220483 wt% 0.02

EPA 3050B/7000B< 0.007PbKAB-4047-L11 LM220484 wt% 0.007

EPA 3050B/7000B< 0.006PbKAB-4047-L12 LM220485 wt% 0.006

EPA 3050B/7000B< 0.007PbKAB-4047-L13 LM220486 wt% 0.007

EPA 3050B/7000B0.042PbKAB-4047-L14 LM220487 wt% 0.009

Analytical results and reports are generated by SGS Forensic Laboratories at the request of and for the exclusive use of the person or entity (client) named on such report.

Results, reports or copies of same will not be released by SGS Forensic Laboratories to any third party without prior written request from client. This report applies only to the sample(s) tested. Supporting laboratory documentation is available upon request. This report must not be reproduced except in full, unless approved by SGS Forensic Laboratories. The client is solely responsible for the use and interpretation of test results and reports requested from SGS Forensic Laboratories. SGS Forensic Laboratories is not able to assess the degree of hazard resulting from materials analyzed. SGS Forensic Laboratories reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified. Any modifications that have been made to referenced test methods are documented in SGS Forensic Laboratories' Standard Operating Procedures Manual. Sample results have not been blank corrected. Quality control and sample receipt condition were acceptable unless otherwise noted.

Note* Sampling data used in this report was provided by the client as noted on the associated chain of custody form.

* The Reporting Limit represents the lowest amount of analyte that the laboratory can confidently detect in the sample, and is not a regulatory level. The Units for the Reporting Limit are the same as the Units for the Final Results.

Kevin Poon, Laboratory Analyst, Hayward Laboratory

3777 Depot Road, Suite 409, Hayward, CA 94545 / Telephone: (510) 887-8828 (800) 827-FASI / Fax: (510) 887-4218

ASBESTOS SAMPLING PHOTOS

Kadena Air Base, Okinawa, Japan

HazMat Survey

Bldg. 4047

Kadena Air Base, Bldg.4047

KAB-4047-A1 KAB-4047-A2

KAB-4047-A3 KAB-4047-A4

KAB-4047-A5 KAB-4047-A6

Kadena Air Base, Bldg.4047

KAB-4047-A7 KAB-4047-A8

KAB-4047-A9 KAB-4047-A10

KAB-4047-A11 KAB-4047-A12

Kadena Air Base, Bldg.4047

KAB-4047-A13 KAB-4047-A14

KAB-4047-A15 KAB-4047-A16

KAB-4047-A17 KAB-4047-A18

Kadena Air Base, Bldg.4047

KAB-4047-A19 KAB-4047-A20

KAB-4047-A21 KAB-4047-A22

KAB-4047-A23 KAB-4047-A24

KAB-4047-A25 KAB-4047-A26

Intentionally Left Blank

KAB-4047-A27

LEAD BASED PAINT SAMPLING PHOTOS

Kadena Air Base, Okinawa, Japan

HazMat Survey

Bldg. 4047

KAB-4047-L1 KAB-4047-L2

KAB-4047-L3 KAB-4047-L4

KAB-4047-L5 KAB-4047-L6

KAB-4047-L7 KAB-4047-L8

KAB-4047-L9 KAB-4047-L10

KAB-4047-L11 KAB-4047-L12

KAB-4047-L13 KAB-4047-L14

APPENDIX E

BUILDING INSPECTOR & LABORATORY CERTIFICATIONS

APPENDIX G

Sampling Personnel and Analytical Laboratory Certifications

THIS PAGE IS INTENTIONALLY LEFT BLANK

SAMPLING PERSONNEL CERTIFICATIONS

is awarded to:

Kenneth Bull

ASBESTOS BUILDING INSPECTOR

REFRESHER TRAINING CERTIFICATE

for attending and successfully completing training under the Toxic Substances Control Act (TSCA); Title II, Asbestos Hazard Emergency Response Act (AHERA); Asbestos Model Accreditation Plan.

Certificate Number

ABIR-20240302-01

Course Date March 2, 2024

Examination Date March 2, 2024

Expiration Date March 2, 2025

This course was conducted by:

98-029 Hekaha Street, Suite 21 Aiea, Hawaii, USA +1.808.486.5881

Accreditation T-13-020 Steven Tanaka - Training Director is awarded to:

Kenneth Bull 3-15-9 Suite 305 Kumoji Naha-shi Okinawa 900-0015 Japan

CERTIFICATE OF COMPLETION

LEAD INSPECTOR

for attending and successfully completing a review of the training curriculum as presented in 40 CFR 745 Lead-Based Paint Poisoning Prevention in Certain Residential Structures.

Certificate Number

LIR-202002160-03

Course Completion Date October 14, 2022

Course Examination Date October 14, 2022

Course Expiration Date October 14, 2025

This course was conducted by:

98-029 Hekaha Street, Suite 21 Aiea, Hawaii, USA +1.808.486.5881

Steven Tanaka, Training Director

Accredited Lead Training Provider PBTP-0012, HAR 11-41 LBP Activities; T664657, EPA LBP Program

LABORATORY CERTIFICATIONS

AIHA Laboratory Accreditation Programs, LLC acknowledges that

Hawaii Analytical Laboratory, LLC 3615 Harding Avenue #308, Honolulu, HI 96816

Laboratory ID: LAP-101812 along with all premises from which key activities are performed, as listed above, has fulfilled the requirements of the AIHA Laboratory Accreditation Programs (AIHA LAP), LLC accreditation to the ISO/IEC 17025:2017 international standard, General Requirements for the Competence of Testing and Calibration Laboratories in the following:

LABORATORY ACCREDITATION PROGRAMS

INDUSTRIAL HYGIENE Accreditation Expires: January 01, 2025

ENVIRONMENTAL LEAD Accreditation Expires: January 01, 2025

ENVIRONMENTAL MICROBIOLOGY Accreditation Expires: January 01, 2025

FOOD Accreditation Expires:

UNIQUE SCOPES Accreditation Expires:

Specific Field(s) of Testing (FoT)/Method(s) within each Accreditation Program for which the above named laboratory maintains accreditation is outlined on the attached Scope of Accreditation. Continued accreditation is contingent upon successful on-going compliance with ISO/IEC 17025:2017 and AIHA LAP, LLC requirements. This certificate is not valid without the attached Scope of Accreditation. Please review the AIHA LAP, LLC website (www.aihaaccreditedlabs.org) for the most current Scope.

Revision20: 06/07/2022

Cheryl O Morton Managing Director, AIHA Laboratory Accreditation Programs, LLC

Date Issued: 01/01/2023

Effective: 06/07/2022 Revision: 9.2

SCOPE OF ACCREDITATION

Hawaii Analytical Laboratory, LLC Laboratory ID: LAP-101812 3615 Harding Avenue #308, Honolulu, HI 96816 Issue Date: 07/14/2023

The laboratory is approved for those specific field(s) of testing/methods listed in the table below. Clients are urged to verify the laboratory's current accreditation status for the particular field(s) of testing/Methods, since these can change due to proficiency status, suspension and/or withdrawal of accreditation.

Industrial Hygiene Laboratory Accreditation Program (IHLAP)

Initial Accreditation Date: 03/24/2000

IHLAP Scope Category Field of Testing (FOT) Technology sub-type/Detector

Published Reference Method/Title of

In-house Method

Component, parameter or characteristic tested

Asbestos/Fiber Microscopy Core

Phase Contrast Microscopy (PCM) - NIOSH 7400 Asbestos/Fibers

Miscellaneous Core Gravimetric - NIOSH 0500 Modified Total Dust

Miscellaneous Core Gravimetric - NIOSH 0600 Modified Respirable Dust

Spectrometry Core Atomic Absorption FAA EPA SW-846 3050B Modified Chromium

Spectrometry Core Atomic Absorption FAA EPA SW-846 3050B Modified Cadmium

Spectrometry Core Atomic Absorption FAA EPA SW-846 7000B Modified Chromium

Spectrometry Core Atomic Absorption FAA EPA SW-846 7000B Modified Cadmium

Spectrometry Core Atomic Absorption FAA NIOSH 7024 Modified Chromium

Spectrometry Core Atomic Absorption FAA NIOSH 7030 Modified Zinc

Spectrometry Core Atomic Absorption FAA NIOSH 7048 Modified Cadmium

Spectrometry Core Atomic Absorption FAA NIOSH 7082 Modified Lead

Spectrometry Core Atomic Absorption FAA NIOSH 7900 Modified Arsenic

Spectrometry Core Atomic Absorption FAA OSHA ID-121 Modified Copper, Manganese, Nickel

A complete listing of currently accredited IHLAP laboratories is available on the AIHA LAP, LLC website at:

http://www.aihaaccreditedlabs.org

DRAFT

aantin Highlight aantin Highlight aantin Highlight aantin Highlight

Effective: 06/07/2022 Revision: 8.2

SCOPE OF ACCREDITATION

Hawaii Analytical Laboratory, LLC Laboratory ID: LAP-101812 3615 Harding Avenue #308, Honolulu, HI 96816 Issue Date: 01/01/2023

The laboratory is approved for those specific field(s) of testing/methods listed in the table below. Clients are urged to verify the laboratory's current accreditation status for the particular field(s) of testing/Methods, since these can change due to proficiency status, suspension and/or withdrawal of accreditation.

The EPA recognizes the AIHA LAP, LLC ELLAP program as meeting the requirements of the National Lead Laboratory Accreditation Program (NLLAP) established under Title X of the Residential Lead-Based Paint Hazard Reduction Act of 1992 and includes paint, soil and dust wipe analysis. Air and composited wipes analyses are not included as part of the NLLAP.

Environmental Lead Laboratory Accreditation Program (ELLAP)

Initial Accreditation Date: 05/01/2004

Component, parameter or characteristic tested Technology sub-type/Detector Method Method Description

(for internal methods only)

Airborne Dust AA NIOSH 7082 Modified N/A

EPA SW-846 3050B Modified N/A

EPA SW-846 7000B Modified N/APaint AA

NIOSH 7082 Modified N/A

Settled Dust by Wipe AA NIOSH 7082 Modified N/A

EPA SW-846 3050B Modified N/A

EPA SW-846 7000B Modified N/ASoil AA

NIOSH 7082 Modified N/A

A complete listing of currently accredited ELLAP laboratories is available on the AIHA LAP, LLC website at:

http://www.aihaaccreditedlabs.org

United States Department of Commerce National Institute of Standards and Technology

Certificate of Accreditation to ISO/IEC 17025:2017

NVLAP LAB CODE: 200757-0

Eurofins EMLab P&K Tustin, CA is accredited by the National Voluntary Laboratory Accreditation Program for specific services, listed on the Scope of Accreditation, for:

Asbestos Fiber Analysis

2024-01-01 through 2024-12-31

Effective Dates For the National Voluntary Laboratory Accreditation Program

This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017.

This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communique dated January 2009).

PN77833 VEHICLE MAINTENANCE SHOP W912HV-19-D-0010

SECTION 01 57 19.11

INDOOR AIR QUALITY (IAQ) MANAGEMENT

08/22

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

U.S. ENVIRONMENTAL PROTECTION AGENCY (EPA)

EPA SW-846 (Third Edition; Update IV) Test Methods for Evaluating Solid Waste:

Physical/Chemical Methods

U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)

29 CFR 1910.1053 Respirable Crystalline Silica

29 CFR 1910.1200 Hazard Communication

29 CFR 1926.1153 Respirable Crystalline Silica

40 CFR 50 National Primary and Secondary Ambient Air Quality Standards

40 CFR 60 Standards of Performance for New Stationary Sources

40 CFR 63 National Emission Standards for Hazardous Air Pollutants for Source Categories

40 CFR 64 Compliance Assurance Monitoring

40 CFR 82 Protection of Stratospheric Ozone

40 CFR 112 Oil Pollution Prevention

40 CFR 122.26 Storm Water Discharges (Applicable to State NPDES Programs, see section 123.25)

40 CFR 152 Pesticide Registration and Classification Procedures

40 CFR 152 - 186 Pesticide Programs

40 CFR 241 Guidelines for Disposal of Solid Waste

40 CFR 243 Guidelines for the Storage and Collection of Residential, Commercial, and Institutional Solid Waste

40 CFR 258 Subtitle D Landfill Requirements

SECTION 01 57 19.11 Page 1

40 CFR 260 Hazardous Waste Management System: General

40 CFR 261 Identification and Listing of Hazardous Waste

40 CFR 261.7 Residues of Hazardous Waste in Empty Containers

40 CFR 262 Standards Applicable to Generators of Hazardous Waste

40 CFR 262.11 Hazardous Waste Determination and Recordkeeping

40 CFR 263 Standards Applicable to Transporters of Hazardous Waste

40 CFR 264 Standards for Owners and Operators of Hazardous Waste Treatment, Storage, and Disposal Facilities

40 CFR 265 Interim Status Standards for Owners and Operators of Hazardous Waste Treatment, Storage, and Disposal Facilities

40 CFR 266 Standards for the Management of Specific Hazardous Wastes and Specific Types of Hazardous Waste Management Facilities

40 CFR 268 Land Disposal Restrictions

40 CFR 273 Standards for Universal Waste Management

40 CFR 273.2 Standards for Universal Waste Management - Batteries

40 CFR 273.3 Standards for Universal Waste Management - Pesticides

40 CFR 273.4 Standards for Universal Waste Management - Mercury Containing Equipment

40 CFR 273.5 Standards for Universal Waste Management - Lamps

40 CFR 273.6 Applicability - Aerosol Cans

40 CFR 279 Standards for the Management of Used Oil

40 CFR 300 National Oil and Hazardous Substances Pollution Contingency Plan

40 CFR 300.125 National Oil and Hazardous Substances Pollution Contingency Plan - Notification and Communications

40 CFR 355 Emergency Planning and Notification

40 CFR 403 General Pretreatment Regulations for

SECTION 01 57 19.11 Page 2

Existing and New Sources of Pollution

40 CFR 745 Lead-Based Paint Poisoning Prevention in Certain Residential Structures

40 CFR 761 Polychlorinated Biphenyls (PCBs) Manufacturing, Processing, Distribution in Commerce, and Use Prohibitions

49 CFR 171 General Information, Regulations, and Definitions

49 CFR 172 Hazardous Materials Table, Special Provisions, Hazardous Materials Communications, Emergency Response Information, and Training Requirements

49 CFR 172.101 Hazardous Material Regulation-Purpose and Use of Hazardous Material Table

49 CFR 173 Shippers - General Requirements for Shipments and Packagings

49 CFR 178 Specifications for Packagings

WASHINGTON STATE ADMINISTRATIVE CODE (WAC)

WAC-173-303-573 Standards for Universal Waste Management

WAC-173-303-573(2) Standards for Universal Waste Management - Batteries

WAC-173-303-573(3) Standards for Universal Waste Management - Mercury-containing Equipment

WAC-173-303-573(5) Standards for Universal Waste Management - Lamps

1.2 DEFINITIONS

1.2.1 Class I and II Ozone Depleting Substance (ODS)

Class I ODS is defined in Section 602(a) of The Clean Air Act. A list of Class I ODS can be found on the EPA website at the following weblink.

https://www.epa.gov/ozone-layer-protection/ozone-depleting-substances .

Class II ODS is defined in Section 602(s) of The Clean Air Act. A list of Class II ODS can be found on the EPA website at the following weblink.

https://www.epa.gov/ozone-layer-protection/ozone-depleting-substances .

1.2.2 Contractor Generated Hazardous Waste

Contractor generated hazardous waste is materials that, if abandoned or disposed of, may meet the definition of a hazardous waste. These waste streams would typically consist of material brought on site by the Contractor to execute work, but are not fully consumed during the course of construction. Examples include, but are not limited to, excess paint thinners (i.e., methyl ethyl ketone, toluene), waste thinners, excess paints, excess solvents, waste solvents, excess pesticides, and

SECTION 01 57 19.11 Page 3 contaminated pesticide equipment rinse water.

1.2.3 Electronics Waste

Electronics waste is discarded electronic devices intended for salvage, recycling, or disposal.

1.2.4 Environmental Pollution and Damage

Environmental pollution and damage is the presence of chemical, physical, or biological elements or agents which adversely affect human health or welfare; unfavorably alter ecological balances of importance to human life; affect other species of importance to humankind; or degrade the environment aesthetically, culturally or historically.

1.2.5 Environmental Protection

Environmental protection is the prevention/control of pollution and habitat disruption that may occur to the environment during construction.

The control of environmental pollution and damage requires consideration of land, water, and air; biological and cultural resources; and includes management of visual aesthetics; noise; solid, chemical, gaseous, and liquid waste; radiant energy and radioactive material as well as other pollutants.

1.2.6 Hazardous Debris

As defined in paragraph SOLID WASTE, debris that contains listed hazardous waste (either on the debris surface, or in its interstices, such as pore structure) in accordance with 40 CFR 261 . Hazardous debris also includes debris that exhibits a characteristic of hazardous waste in accordance with 40 CFR 261 .

1.2.7 Hazardous Materials

Hazardous material is any material that: Is defined in 49 CFR 171 , listed in 49 CFR 172 , regulated as a hazardous material in accordance with 49 CFR 173 ; or requires a Safety Data Sheet (SDS) in accordance with 29 CFR 1910.1200 ; or during end use, treatment, handling, packaging, storage, transportation, or disposal meets or has components that meet or have potential to meet the definition of a hazardous waste as defined by 40 CFR 261 Subparts A, B, C, or D. Designation of a material by this definition, when separately regulated or controlled by other sections or directives, does not eliminate the need for adherence to that hazard-specific guidance which takes precedence over this section for "control" purposes. Such material includes ammunition, weapons, explosive actuated devices, propellants, pyrotechnics, chemical and biological warfare materials, medical and pharmaceutical supplies, medical waste and infectious materials, bulk fuels, radioactive materials, and other materials such as asbestos, mercury, and polychlorinated biphenyls (PCBs).

1.2.8 Hazardous Waste

Hazardous Waste is any material that meets the definition of a solid waste and exhibits a hazardous characteristic (ignitability, corrosivity, reactivity, or toxicity) as specified in 40 CFR 261 , Subpart C, or contains a listed hazardous waste as identified in 40 CFR 261 , Subpart D, or meets a state, local, or host nation definition of a hazardous waste.

SECTION 01 57 19.11 Page 4

1.2.9 Installation Pest Management Coordinator

Installation Pest Management Coordinator (IPMC) is the individual officially designated by the Installation Commander to oversee the Installation Pest Management Program and the Installation Pest Management Plan.

1.2.10 Land Application

Land Application means spreading or spraying discharge water at a rate that allows the water to percolate into the soil. No sheeting action, soil erosion, discharge into storm sewers, discharge into defined drainage areas, or discharge into the "waters of the United States" must occur.

Comply with federal, state, and local laws and regulations.

1.2.11 Municipal Separate Storm Sewer System (MS4) Permit

MS4 permits are those held by municipalities or installations to obtain NPDES permit coverage for their stormwater discharges.

1.2.12 National Pollutant Discharge Elimination System (NPDES)

The NPDES permit program controls water pollution by regulating point sources that discharge pollutants into waters of the United States.

1.2.13 Oily Waste

Oily waste are those materials that are, or were, mixed with Petroleum, Oils, and Lubricants (POLs) and have become separated from that POLs.

Oily wastes also means materials, including wastewaters, centrifuge solids, filter residues or sludges, bottom sediments, tank bottoms, and sorbents which have come into contact with and have been contaminated by, POLs and may be appropriately tested and discarded in a manner which is in compliance with other state and local requirements.

This definition includes materials such as oily rags, "kitty litter" sorbent clay and organic sorbent material. These materials may be land filled provided that: It is not prohibited in other state regulations or local ordinances; the amount generated is "de minimus" (a small amount);

it is the result of minor leaks or spills resulting from normal process operations; and free-flowing oil has been removed to the practicable extent possible. Large quantities of this material, generated as a result of a major spill or in lieu of proper maintenance of the processing equipment, are a solid waste. As a solid waste, perform a hazardous waste determination prior to disposal. As this can be an expensive process, it is recommended that this type of waste be minimized through good housekeeping practices and employee education.

1.2.14 Pesticide

Pesticide is any substance or mixture of substances intended for preventing, destroying, repelling, or mitigating any pest, or intended for use as a plant regulator, defoliant or desiccant.

1.2.15 Pesticide Treatment Plan

A plan for the prevention, monitoring, and control to eliminate pest infestation.

SECTION 01 57 19.11 Page 5

1.2.16 Pests

Pests are arthropods, birds, rodents, nematodes, fungi, bacteria, viruses, algae, snails, marine borers, snakes, weeds and other organisms (except for human or animal disease-causing organisms) that adversely affect readiness, military operations, or the well-being of personnel and animals; attack or damage real property, supplies, equipment, or vegetation; or are otherwise undesirable.

1.2.17 Project Pesticide Coordinator

The Project Pesticide Coordinator (PPC) is an individual who resides at a Civil Works Project office and who is responsible overseeing of pesticide application on project grounds.

1.2.18 Regulated Waste

Regulated waste are solid wastes that have specific additional federal, state, or local controls for handling, storage, or disposal.

1.2.19 Sediment

Sediment is soil and other debris that have eroded and have been transported by runoff water or wind.

1.2.20 Solid Waste

Solid waste is a solid, liquid, semi-solid or contained gaseous waste. A solid waste can be a hazardous waste, non-hazardous waste, or non-Resource Conservation and Recovery Act (RCRA) regulated waste. Types of solid waste typically generated at construction sites may include:

1.2.20.1 Debris

Debris is non-hazardous solid material generated during the construction, demolition, or renovation of a structure that exceeds 60 mm particle size that is: a manufactured object; plant or animal matter; or natural geologic material (for example, cobbles and boulders), broken or removed concrete, masonry, and rock asphalt paving; ceramics; roofing paper and shingles. Inert materials [may][may not] be reinforced with or contain ferrous wire, rods, accessories and weldments. A mixture of debris and other material such as soil or sludge is also subject to regulation as debris if the mixture is comprised primarily of debris by volume, based on visual inspection.

1.2.20.2 Green Waste

Green waste is the vegetative matter from landscaping, land clearing and grubbing, including, but not limited to, grass, bushes, scrubs, small trees and saplings, tree stumps and plant roots. Marketable trees, grasses and plants that are indicated to remain, be re-located, or be re-used are not included.

1.2.20.3 Material Not Regulated As Solid Waste

Material not regulated as solid waste is nuclear source or byproduct materials regulated under the Federal Atomic Energy Act of 1954 as amended; suspended or dissolved materials in domestic sewage effluent or irrigation return flows, or other regulated point source discharges;

SECTION 01 57 19.11 Page 6 regulated air emissions; and fluids or wastes associated with natural gas or crude oil exploration or production.

1.2.20.4 Non-Hazardous Waste

Non-hazardous waste is waste that is excluded from, or does not meet, hazardous waste criteria in accordance with 40 CFR 261 .

1.2.20.5 Recyclables

Recyclables are materials, equipment and assemblies such as doors, windows, door and window frames, plumbing fixtures, glazing and mirrors that are recovered and sold as recyclable,[ wiring,][ insulated/non-insulated copper wire cable,][ wire rope,] and structural components. It also includes commercial-grade refrigeration equipment with Freon removed, household appliances where the basic material content is metal, clean polyethylene terephthalate bottles, cooking oil, used fuel oil, textiles, high-grade paper products and corrugated cardboard, stackable pallets in good condition, clean crating material, and clean rubber/vehicle tires. Metal meeting the definition of lead contaminated or lead based paint contaminated [may][may not] be included as recyclable if sold to a scrap metal company. Paint cans that meet the definition of empty containers in accordance with 40 CFR 261.7 may be included as recyclable if sold to a scrap metal company.

1.2.20.6 Surplus Soil

Surplus soil is existing soil that is in excess of what is required for this work, including aggregates intended, but not used, for on-site mixing of concrete, mortars, and paving. Contaminated soil meeting the definition of hazardous material or hazardous waste is not included and must be managed in accordance with paragraph HAZARDOUS MATERIAL MANAGEMENT.

1.2.20.7 Scrap Metal

This includes scrap and excess ferrous and non-ferrous metals such as reinforcing steel, structural shapes, pipe, and wire that are recovered or collected and disposed of as scrap. Scrap metal meeting the definition of hazardous material or hazardous waste is not included.

1.2.20.8 Wood

Wood is dimension and non-dimension lumber, plywood, chipboard, hardboard. Treated or painted wood that meets the definition of lead contaminated or lead based contaminated paint is not included. Treated wood includes, but is not limited to, lumber, utility poles, crossties, and other wood products with chemical treatment.

1.2.21 Surface Discharge

Surface discharge means discharge of water into drainage ditches, storm sewers, or creeks meeting the definition of "waters of the United States". Surface discharges from construction sites are discrete, identifiable sources and require a permit from the governing agency.

Comply with federal, state, and local laws and regulations.

1.2.22 Wastewater

Wastewater is the used water and solids that flow through a sanitary sewer

SECTION 01 57 19.11 Page 7 to a treatment plant.

1.2.22.1 Stormwater

Stormwater is any precipitation in an urban or suburban area that does not evaporate or soak into the ground, but instead collects and flows into storm drains, rivers, and streams.

1.2.23 Waters of the United States

Waters of the United States means Federally jurisdictional waters, including wetlands, that are subject to regulation under Section 404 of the Clean Water Act or navigable waters, as defined under the Rivers and Harbors Act.

1.2.24 Wetlands

Wetlands are those areas that are inundated or saturated by surface or groundwater at a frequency and duration sufficient to support, and that under normal circumstances do support, a prevalence of vegetation typically adapted for life in saturated soil conditions.

1.2.25 Universal Waste

The universal waste regulations streamline collection requirements for certain hazardous wastes in the following categories: batteries, pesticides, mercury-containing equipment (for example, thermostats), and lamps (for example, fluorescent bulbs). The rule is designed to reduce hazardous waste in the municipal solid waste (MSW) stream by making it easier for universal waste handlers to collect these items and send them for recycling or proper disposal. These regulations can be found at

40 CFR 273 .

1.2.26 Location Specific Universal Waste

Any of the following dangerous waste that are subject to the universal waste requirements of WAC-173-303-573 : Batteries as described in WAC-173-303-573(2) ); Lamps as described in WAC-173-303-573(5) ;

Mercury-containing equipment as described in WAC-173-303-573(3) .

1.3 SUBMITTALS

Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are [for Contractor Quality Control approval.][for information only. When used, a code following the "G" classification identifies the office that will review the submittal for the Government.] Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-01 Preconstruction Submittals

Preconstruction Survey

Regulatory Notifications ; G[, [_____]]

Environmental Manager Qualifications ; G[, [_____]]

Employee Training Records ; G[, [_____]]

SECTION 01 57 19.11 Page 8

Environmental Protection Plan ; G[, [_____]]

Dirt and Dust Control Plan ; G[, [_____]]

Solid Waste Management Permit ; G[, [_____]]

[ Stormwater Pollution Prevention Plan (SWPPP); G[, [_____]]

][ Stormwater Notice of Intent (for NPDES coverage under the general permit for construction activities); G[, [_____]]

] Spill Prevention Control And Countermeasure (SPCC) Plan ; G[, SD-06 Test Reports

Monthly Solid Waste Disposal Report ; G[, [_____]]

[ Inspection Reports

][ Laboratory Analysis

] SD-07 Certificates

Employee Training Records ; G[, [_____]]

[ Erosion and Sediment Control Inspector Qualifications

Certificate of Competency

SD-11 Closeout Submittals Regulatory Notifications ; G[, [_____]]

Assembled Employee Training Records ; G[, [_____]]

Solid Waste Management Permit ; G[, [_____]]

[ Stormwater Pollution Prevention Plan Compliance Notebook ; G[, ][ Stormwater Notice of Termination (for NPDES coverage under the general permit for construction activities); G[, [_____]]

][ As-Built Topographic Survey

] Waste Determination Documentation ; G[, [_____]]

Project Solid Waste Disposal Documentation Report ; G[, [_____]]

Sales Documentation ; G[, [_____]]

[ Contractor Certification

] Hazardous Waste/Debris Management ; G[, [_____]]

Disposal Documentation for Hazardous and Regulated Waste ; G[, SECTION 01 57 19.11 Page 9

1.4 ENVIRONMENTAL PROTECTION REQUIREMENTS

Provide…