Sources Sought Attachment W912HV26Z0012 VMS Intermediate DRAWINGS DRAFT_Part7.pdf
PDF 20 MB Posted
- Solicitation number
- W912HV26Z0012
About this file
This file is an intermediate design drawing package (dated 12/17/2025) for the Vehicle Maintenance Shop (VMS) and associated support facilities at Kadena Air Base, Okinawa, Japan. The drawings cover six Contract Line Item Numbers (CLINs): CLIN 0001 for the VMS building (approximately 5,100 square meters), CLIN 0002 for organizational storage and hazardous material storage buildings, CLIN 0003 (not separately documented), CLIN 0004 for a secure storage annex warehouse and Company Operations Facility Swing Space, and additional CLINs for fire pump, cable hut, water tank, and transformer enclosures. The design includes detailed architectural floor plans, elevations, sections, reflected ceiling plans, roof plans, air barrier plans, signage plans, mechanical and electrical system layouts, and furniture/equipment placement plans. Key architectural features encompass a two-story vehicle maintenance facility with elevator systems, secure vaults, administrative spaces, training rooms, maintenance areas with bridge cranes, and comprehensive building systems including HVAC, plumbing, fire protection, electrical distribution, and communications infrastructure.
The drawings specify materials and finishes including spray tile systems on concrete, fluid-applied roofing, stainless steel hardware, various door and window assemblies, aluminum railings, and decorative breeze block elements. Mechanical systems feature variable air volume (VAV) terminal units, air-cooled chillers, dedicated outside air systems (DOAS), and exhaust fans. Infrastructure components include a two-stage elevator system (1,750 kg capacity, 1.0 m/sec), emergency systems, accessible facilities compliant with accessibility standards, and comprehensive fire safety provisions. The design incorporates seismic bracing requirements per ASCE 7-16 and ASTM E580 standards. Design Partners Incorporated of Honolulu prepared these intermediate design documents for the Japan District, U.S. Army Corps of Engineers, representing progress toward final design and eventual competitive solicitation for construction services.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FLOOR 1 (VMS)
FLOOR 2 (VMS)
A7A8
ELEV PIT (VMS)
-1500
HALL
A121
ELEV
LOBBY
A213
ELEVATOR
AE01
PILE FOUNDATION
SEE STRUCT, TYP.
STAIR 2
AS02
ELEVATOR HOIST BEAM,
SEE STRUCT DWGS
ELEVATOR
PIT LADDER
A-534
E1
A-534
M10
C L R
R .O
C L R
R .O
CONTROL POINT 1 (VMS)
AD
A7
A7
A8
A8
G1
A-A720
NURSING
ROOM
A140
ELEV
EQUIPMENT
ROOM
A117
HALL
A121
STAIR 2
AS02
ARMS
VAULT
A114
ELEVATOR
AE01
H O
IS
T
W A
Y
P
IT
HOISTWAY & PIT
REMOVABLE
STEEL GRATE
G10
A-A720
ENTRY MAT
6502800
A-A403
M12
C L
R .O
C L R
CONTROL
PANEL
AD AD
A7
A7
A8
A8
G1
A-A720
AS02
STAIR 2
HOISTWAY & PIT
3150 2525
ELEV
LOBBY
A213
CORRIDOR
A201
TRAINING
ROOM
A205
MEN
A211
H O
IS
T
W A
Y
P
IT
G10
A-A720
C L
R .O
C L R
FLOOR 2 (VMS)
AD
ELEV PIT (VMS)
-1500
PILE FOUNDATION
SEE STRUCT
DWGS, TYP.
REMOVABLE
STEEL GRATE
ELEVATOR
PIT LADDER
ELEVATOR
AE01
ELEV
EQUIPMENT
ROOM
A117
TRAINING
ROOM
A205
ELEVATOR
SUMP PIT
ELEVATOR HOIST BEAM,
SEE STRUCT DWGS FOR
ADDITIONAL INFORMATION
A-534
I10
OPENING WIDTH
E N
T R
A N
C E
H E
IG
H
T
1300 1550
FLOOR 1 (VMS)
CONTROL POINT 1 (VMS)
C L E
A R
1. DIMENSIONS MARKED "CLR" ARE FROM FINISH SURFACE TO
FINISH SURFACE.
2. FURNITURE AND EQUIPMENT ARE SHOWN IN DASHED FOR
REFERENCE ONLY.
3. REFER TO SHEET A-601 AND A-602 FOR DOOR SCHEDULES.
4. REFER TO SHEET A-611 FOR WINDOW AND LOUVER
SCHEDULES.
5. REFER TO SHEET A-621 FOR MATERIAL FINISH SCHEDULES.
6. REFER TO SHEET A-622 FOR ROOM FINISH SCHEDULES.
7. REFER TO SHEETS A-731 TO A-746 FOR ELEVATOR DESIGN
DRAWINGS AND SPECIFICATIONS.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:4
A M
A-A720
E N
L A
R G
E D
F L
O O
R P
L A
N S
A N
D S
E C
T
IO
N
V M
S E
L E
V A
T O
R
A P
O A
P
-5
K .E
L L
IN
G W
O O
D
I.
R
O L L O
J .M
A N
U
IA
D .M
O A
T S
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
SCALE: 1 : 50
1000 2000
GENERAL NOTES
GRAPHIC SCALE
1 : 50G1
ELEVATOR SECTION 1
1 : 50A1
VMS - FIRST FLOOR ELEVATOR PLAN (CLIN 0001)
1 : 50A10
VMS - SECOND FLOOR ELEVATOR PLAN (CLIN 0001)
1 : 50G10
ELEVATOR SECTION 2
PLAN
NORTH
DRAFT
NO.1
1. PROVISIONS
2. PROVISION OF REMOVAL OF THE EXISTING ELEVATOR AND REPAIRING THE SHAFT.
3. PROVISION OF STEELS TO INSTALL JAMBS, INDICATORS, BUTTONS, HANGAR CASES, ETC.
4. PROVISION OF MORTAR AROUND THE ENTRANCE FRAMES OF ALL FLOORS.
5. FINISHING OF WALLS AND FLOORS AROUND THE ENTRANCE FRAMES OF ALL FLOORS.
6. SHATTERING AND REPAIRING OF BASE OF THRESHOLD OF ALL FLOORS.
7. PROVISION OF WATERPROOFING IN THE PIT.
8. PROVISION OF TEMPORARY ENTRANCE FOR CARRYING-IN AND RESTORATION WORK.
(INCLUDES INSTALLATION AND RESTORATION WORK OF MACHINE ROOM DELIVERY ENTRANCE)
9. PROVISION OF SUPPORTS FOR MACHINE BEAM AND SPACER.
10. SHATTERING OF CINDER CONCRETE OF MACHINE ROOM FLOORS.
11. PROVISION OF FILLING UP THE OPENINGS AND ANOTHER OPENINGS ON THE MACHINE ROOM FLOOR.
12. PROVISION OF CINDER CONCRETE OF MACHINE ROOM FLOOR.
13. PROVISION OF DUST-PROOFING ON THE MACHINE ROOM FLOOR.
SERVICE
VARIABLE VOLTAGE VARIABLE FREQUENCY CONTROL
SELECTIVE COLLECTIVE AUTOMATIC
1750 KG (26 PERSONS)
1.0 M/SEC
AC 3-PHASE 200 VOLTS 60 Hz
KPM-2000 11.0 Kw
10 DIA X 6 2:1 ROPING
ISO T127-1/B
1~2 FL TOTAL 2 STOPS/OPENING
WIDTH 1500MM X DEPTH 2500MM X HEIGHT 2300MM
WIDTH 1220MM X DEPTH 2135MM
TWO PANEL SIDE OPENING DOOR AUTOMATIC DOORS
SPRING BUFFER
EMERGENCY LANDING DEVICE
UNINTENDED CAR MOVEMENT PROTECTION,
COMPLY WITH (2009) THE BUILDING STANDARDS ACT
EARTHQUAKE PROTECTION CLASS: A14
MULTIPLE BEAM DOOR CENSOR
CAR CALL CANCEL
AUTOMATIC ANNOUNCE
SENDING THE TROUBLE SIGNAL
FASCIA PLATE
CAR EMERGENCY TELEPHONE
BRAILLE PLATE (LOBBY PUSH BUTTON, CAR OPERATING PANEL)
COUNTER WEIGHT GUARD
EARTHQUAKE ROPE-JUMP GUARDS
STANDARD RAILING
DOOR CLOSER
EARTHQUAKE EMERGENCY RETURN OPERATION
FIREFIGHTERS' SERVICE 2005 ASME A17, 1, 2, 27
STANDARD FLOOR (1ST FLOOR)
HOISTWAY ACCESS SWITCH
SHEAVE SIDE COVER
LOBBY DOOR FALL PROTECTION DEVICE
LOBBY DOOR SILL AND CAR SILL: STAINLESS STEEL
BUTTONS: STAINLESS STEEL
LOBBY DOOR UL FIREPROOF
CAR DOOR SAFETY DEVICE (WITH AREA SENSOR)
NUMBER
USE
CONTROL
OPERATION
CAPACITY
SPEED
POWER
HOISTING MOTOR
ROPE
GUIDE RAIL
SERVICE FL
CAR INTERNAL
DOOR OPENING
DOOR TYPE
BUFFER
OPTION
ELEVATOR SPECIFICATIONS
WORK NOT INCLUDED BY ELEVATOR CONSTRUCTION
CW 1900
UCMP CERTIFICATION NUMBER: ENNNUN-2470
WORK BY BUILDING CONSTRUCTOR
1. WIRING AND CONNECTION OF POWER CABLES, LIGHTING CABLES AND GROUNDING WIRES TO THE
RECEIVING TERMINALS IN THE MACHINE ROOM.
2. PIPING & WIRING WORK FOR CAR TELEPHONE USE BETWEEN HOIST WAY / MACHINE ROOM
AND EXTERNAL PLACE TO BE INSTALLED.
3. WIRING AND PIPING FOR FIRE ALARM SIGNALS OUTSIDE OF THE MACHINE ROOM.
4. PIPING AND WIRING FROM HOIST WAY TO OUTSIDE FOR SECURITY CAMERA & MONITOR IN THE CAR.
5. PROVISION OF OUTLET FOR MAINTENANCE IN THE PIT.
6. PROVISION OF SMOKE DETECTORS ON THE CEILING ON THE MACHINE ROOM AND TOP OF THE SHAFT.
7. PROVISION OF LIGHTING AND OUTLET FOR MAINTENANCE IN THE MACHINE ROOM.
8. POWER CIRCUIT BREAKER DRAWER POWER SUPPLY.
WORK BY ELECTRICIAN
1. USE THE CONCRETE WITH THE STRENGTH OF 21N / MM2 OR MORE.
2. POWER VOLTAGE VARIATION MUST BE WITHIN - 10% OR +5%
AND VOLTAGE UNBALANCE FACTOR MUST BE 5% OR LESS.
3. TO MAINTAIN PERFORMANCE OF THE ELEVATOR, FOLLOW THE CONDITIONS BELOW.
(1) TEMPERATURE IN THE SHAFT AND MACHINE ROOM: 40 DEGREES CELCIUS OR LESS
MONTHLY AVERAGE HUMIDITY: 90% OR LESS, DAILY AVERAGE HUMIDITY: 95% OR LESS
(2) DUST OR TOXIC GAS WHICH MAY CAUSE WEAR OR CORROSION OF METAL
OR CONTACT FAILURE IS NOT ALLOWED
4. PROVIDE A ROOF, SLOPE (FOR FLOORS) OR DRAINAGE
IF WATER MAY COME INTO THE HALL
5. DO NOT EMBED DUCT OR EQUIPMENT FOR ELECTRICITY OR WATER IN THE SHAFT WALL.
6. KEEP THE MAIN POWER LINE FOR ELEVATORS AT LEAST 1M AWAY FROM POWER SUPPLY GABLES AND COMMUNICATION LINES FOR COMMUNICATION DEVICES OR OTHER LIGHT ELECTRICAL APPLIANCES.
7. KEEP THE POWER TRANSFORMER FOR ELEVATORS AWAY FROM THAT FOR COMMUNICATION
DEVICES OR OTHER LIGHT ELECTRICAL APPLIANCES.
8. KEEP THE GROUNDING WIRE FOR ELEVATORS AWAY FROM THAT FOR THE POWER
TRANSFORMER OF COMMUNICATION DEVICES OR OTHER LIGHT ELECTRICAL APPLIANCES.
9. USE THE BREAKER FOR INVERTER CIRCUIT.
10. KEEP THE GROUNDING WIRE FOR NEUTRAL POINT OF THE POWER TRANSFORMER
FOR ELEVATORS AWAY FROM THE GROUNDING ROD.
11. DO NOT CARRY HEAVY LOAD SUCH AS CARRIAGE
WHICH EXCEEDS 250 KG.
NOTES
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:4
A M
A-A721
E L
E V
A T
O R
S P
E C
IF
IC
A T
IO
N
S
A P
O A
P
-5
K .E
L L
IN
G W
O O
D
I.
R
O L L O
J .M
A N
U
IA
D .M
O A
T S
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
S
HOIST WAY WIDTH
PLATFORM WIDTH
1550 775
CAR INT. WIDTH
PIT WAY PLAN
1 FL HOIST WAY PLAN
2 FL HOIST WAY PLAN
3250HOISTWAY WIDTH
1300 1550
H O
IS
T
W A
Y D
E P
T H
WATERPROOFING MEMBRANE
GRATING
H O
IS
T
W A
Y D
E P
T H
P L A
T F
O R
M D
E P
T H
PIT LADDER
PIT OUTLET
OPENING WIDTH
1365 135 1750
CL
CONTROL PANEL
POWER SUPPLY INPUT
HOIST WAY WIDTH
PLATFORM WIDTH
1550 775
CAR INTERIOR WIDTH
H O
IS
T
W A
Y D
E P
T H
P L A
T F
O R
M D
E P
T H
C A
R I N
T E
R
IO
R D
E P
T H
OPENING WIDTH
1365 135 1750
SMOKE DETECTOR
LOW VOLTAGE WIRING WORK:
INTERCOM WIRING
FIRE SIGNAL LINE
POWER SUPPLY INSTALLATION WORK:
FOR POWER 200V
FOR LIGHTING 100V
REACTION FORCE
43 KN LONG TERM LOADR1
R2
R3
R4
R5
R6
PIT
42 KN LONG TERM LOAD
41 KN LONG TERM LOAD
36 KN LONG TERM LOAD
81.1 KN LONG TERM LOAD
60.1 KN LONG TERM LOAD
EARTHQUAKE RAIL REACTION FORCE
Px
Py Py
CAR
COUNTER
Px
Py
Px
Py
13.8 KN SHORT TERM LOAD
6.9 KN LONG TERM LOAD
21.8 KN LONG TERM LOAD
10.9 KN LONG TERM LOAD
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:4
A M
A-A722
H O
IS
T
W A
Y P
L A
N S
A P
O A
P
-5
K .E
L L
IN
G W
O O
D
I.
R
O L L O
J .M
A N
U
IA
D .M
O A
T S
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
SCALE: 1 : 20
400 800
1 : 20A1
HOIST WAY PLANS
S H
A F
T T
O T
A L H
E
IG
H T
HOIST SECTION A-A HOIST SECTION B-A
1 FL
2 FL
1 FL
2 FL
HOISTWAY DEPTH
1125 2025SMOKE DETECTOR
P
IT
D E
P T
H
T R
A V
E L D
IS
T
A N
C E
E N
T R
A N
C E
H E
IG
H
T
E N
T R
A N
C E
H E
IG
H
T
OPENING WIDTH
HOISTWAY WIDTH
BEAM
E N
T R
A N
C E
H E
IG
H
T
S H
A F
T T
O T
A L H
E
IG
H T
P
IT
D E
P T
H
E N
T R
A N
C E
H E
IG
H
T
OPENING WIDTH
PISTON
PIT WATER PROOFING
LOW VOLTAGE WIRING WORK:
INTERCOM WIRING
FIRE SIGNAL LINE
POWER SUPPLY INSTALLATION WORK:
FOR POWER 200V
FOR LIGHTING 100V
CONTROL PANELCONTROL PANEL
GRATING
PIT
OUTLET
PIT
LADDER
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:4
A M
A-A723
H O
IS
T
W A
Y S
E C
T
IO
N S
A P
O A
P
-5
K .E
L L
IN
G W
O O
D
I.
R
O L L O
J .M
A N
U
IA
D .M
O A
T S
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
500 1000
SCALE: 1 : 25
1 : 25A1
HOIST WAY SECTIONS
EXAMPLE OF SMOKE DETECTOR CONSTRUCTION
LOCK SCREW
INSPECTOR SWITCH
INSPECTION DOOR
(MADE OF IRON
OVER 1.5MM) (ELV
INTERLOCKING
SWITCH, LOCKABLE
IRON DOOR)
CEILING
OPENING
MOUNTING
PLATE
SMOKE
DETECTOR
HOISTWAY
CONSTRUCTION EXAMPLE
90 3
.5
.5
DIRECTION INDICATOR
POSITION INDICATOR
PARK
FIRE
MESSAGE INDICATOR
PARK/EMERGENCY SWITCH
FE SWTICH
UP BUTTON
BRAILLE TEXT
DOWN BUTTON
BRAILLE TEXT
90 3
.5
.5
DIRECTION INDICATOR
PARK
FIRE
DIRECTION INDICATOR
MESSAGE INDICATOR
UP BUTTON
BRAILLE TEXT
DOWN BUTTON
BRAILLE TEXT
HANDICAP SIGN HANDICAP SIGN
1ST FLOOR 2ND FLOOR
FACE PLATE 3.0 STAINLESS STEEL HAIRLINE FINISH
INDICATOR RESIN PLATE FACE-TO-FACE
DIRECTION LIGHT LED DISPLAY GREEN
FLOOR INDICATOR
LIGHT LED DISPLAY RED
SERVICE
INDICATOR LIGHT
CONTROL
INDICATOR LIGHT
FIREFIGHTER
LAMP
PUSH BUTTON
INTERNATIONAL
MARK
LETTER
PARKING SWITCH
FIREFIGHTER
SWITCH
BACKLIGHT LED DISPLAY RED
BACKLIGHT LED DISPLAY RED
ROUND LED DISPLAY RED
TAMPER-RESISTANT BUTTON
SILK PRINTING
SILK PRINTING BLACK LETTERS
FACE TO FACE
FED-K1
SPECIFICATIONS
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:5
A M
A-A724
H A
L L
P O
S
IT
IO
N
I N
D
IC
A T
O R
D R
A W
IN
G
A P
O A
P
-5
K .E
L L
IN
G W
O O
D
I.
R
O L L O
J .M
A N
U
IA
D .M
O A
T S
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
SCALE: 1 : 2
40 80
1 : 2A1
HALL POSITION INDICATOR
FINISH
SURFACE
29 DIA X 100L
10 1510 10
5 X 2 - 8 DIA X 20L
CHAMFER
FINISH
55 50 55 60 430
N O
S M
O K
IN
G
P A
S S
E N
G E
R C
A P
A C
IT
Y k g
P E
R S
O N
S
E A
R T
H Q
U A
K E
P O
W E
R F
A
IL
U R
E
F
IR
E
LE
A
V E
T H
E C
A R
W H
E N
D O
O R
S O
P E
N
F
IR
E O
P E
R A
TI
O
N
火 災
時 運
転
W he n f la sh in g ex it el ev at or
点 滅
し て
い る
と き
は エ
レ ベ
ー タ
ー 使
用 禁
止
To o pe ra te c ar
運 転
To c an ce l f lo or d es tin at io n
行 き
先 階
を キ
ャ ン
セ ル
To c lo se d oo r
ド ア
閉 め
To o pe n do or
ド ア
開 く
To h ol d ca r at fl oo r
カ ゴ
を 止
め て
お く
F or e m er ge nc y st op
緊 急
停 止
To a ut om at ic al ly s en d ca r to r ec al l f lo or
自 動
で 元
の 階
に 戻
る
In se rt fi re k ey a nd tu rn to
O
N
P re ss d es ire d bu tto n.
カ ギ
を 差
込 み
" O N
" に 回
し
行 き
先 階
ボ タ
ン を
押 す
P re ss
C A
LL
C
A N
C E
L" b ut to n.
"C A
LL
C
A N
C E
L" ボ
タ ン
を 押
す
P re ss a nd h ol d
"C
LO
S E bu tto n.
"C
LO
S E
" ボ タ
ン を
押 し
続 け
る
P re ss a nd h ol d
"O P
E N bu tto n.
"O P
E N
" ボ タ
ン を
押 し
続 け
る
W ith d oo rs o pe n, T ur n ke y to
H
O
LD
ド ア
が 開
い て
い る
間 に
カ
ギ を
"H O
LD
" に
回 す
U se
S
TO
P sw itc h.
"S
TO
P " ス
イ ッ
チ を
押 す
Tu rn k ey to
O F
F
カ ギ
を "O
F F
" に 回
す
F
IR
E F
IG
H
T E
R S
' O P
E R
A
TI
O N
F O
R M
A
IN
T E
N A
N C
E U
S E
O N
LY
A
LA
R M
2 1 O P
E N
C
LO
S E
E X
TE
N
D O
P E
N
O F
F
O N
IN
D
S V
C
C A
LL
C
A N
C E
L
O P
E N
F
IR
E O
P E
R A
T
IO
N
H O
LD
O
F F
O N
C
LO
S E
R U
N
S
TO
P
F A
N
LO
W
H
IG
H
O F
F
LI
G
H T
R U
N
O F
F S
TO
P
O F
F
R F
C U
T
O F
F O
F F
F R
E E
E A
C H
F
LO
O R
C U
T F
R E
E
O F
F O
F F
O F
F
C H
E C
K D
O O
R A
U
TO
C U
T
N O
R M
A L
IN
S
P E
C
TI
O
A C
C
A C
C E
S S
E N
A B
LE
FOR MAINTENANCE
USE ONLY
CLOSE
OPEN
1 2
FOR MAINTENANCE
USE ONLY
CLOSE
OPEN
1 2
85 3
125 200 555
R3
2X2 - 8 DIA X 20L
POSITION
INDICATOR
DIRECTION
INDICATOR
"EARTHQUAKE"
"POWER FAILURE"
RUNNING
INDICATOR
"FIRE" CHARACTER HEIGHT, 10MM
SILK PRINTING RED LETTERS
OPEN DOOR KEY
INTERCOM BUTTON
WITH COVER
ALARM
BUTTON
CAR BUTTONS BRAILLE TEXT
DOOR OPEN
BUTTON
DOOR CLOSE BUTTON
EXTEND OPEN BUTTON
INDICATOR LIGHT
INDEPENDENT
SERVICE KEY
CAR FLOOR +1200
DOOR CLOSE
BUTTON
NEARBY FLOOR
STOP SWITCH
SWITCH FOR
RESCUE
DOOR OPEN
BUTTON
CALL CANCEL
BUTTON
THE SWITCH IN SWITCH COVER
ACCESS ENABLE
SWITCH
GFCI
OUTLET
2X2 - 8 DIA X 20L
HANDICAPPED
MARK
DIRECTION
INDICATOR
POSITION
INDICATOR
INTERCOM
BUTTON WITH
COVER
CAR
BUTTONS
BRAILLE
TEXT
DOOR OPEN
BUTTON
DOOR CLOSE
BUTTON
65 100 90 100 65
C A
R F
L O
O R
ACCESSIBLE CONTROL PANEL DETAIL (MAIN PANEL)
1 SET
29 DIA X 100L
HANDICAPPED
MARK
DIRECTION
INDICATOR
POSITION
INDICATOR
INTERCOM
BUTTON WITH
COVER
CAR
BUTTONS
BRAILLE
TEXT
DOOR OPEN
BUTTON
DOOR CLOSE
BUTTON
C A
R F
L O
O R
ACCESSIBLE CONTROL PANEL DETAIL (SECONDARY PANEL)
1 SET
29 DIA X 100L
65 100 90 100 65
R3R3
FACE PLATE 3.0 STAINLESS STEEL HAIRLINE FINISH
INDICATOR DARK RESIN PLATE
(FOR FACEPLATE ALIGNMENT)
DIRECTION LIGHT DOT MATRIX LED DISPLAY
(LIGHT COLOR: GREEN)
FLOOR INDICATOR DOT MATRIX LED DISPLAY
LIGHT (LIGHT COLOR: RED)
CONTROL INDICATOR BACKLIGHT LED DISPLAY
LIGHT (LIGHT COLOR: RED)
PUSH BUTTON BT-24106-37 (LIGHT COLOR: BLUE)
TAMPER-RESISTANT BUTTON
(VANDAL-RESISTANT)
LETTER SILK PRINTING BLACK LETTERS
* [NO SMOKING]: RED LETTERS
INTERNATIONAL MARK SILK PRINTING ON BLUE BACKGROUND
(30 X 30)
RESCUE SWITCH OFF/HOLD: ON: INSTALLED
D8161-PH2-FE0K1-14
* INSTALLED SO THAT IT FITS INSIDE THE BOX
* THE KEY IS THE SAME AS THE LANDING FIRE
BRIGADE SWITCH AND SWING DOOR COVER
INDICATOR LIGHT AR22JR-2B11B (FUJI ELECTRIC)
ACCESS ENABLE IDEC HA3K-3C2A KEY NUMBER 231 SAME AS
SWITCH THE KEY FOR THE PLATFORM ACCESS SWITCH
GFCI OUTLET GFRST151
SPECIFICATION
• CHAMFERED AROUND THE FACE PLATE
• OPERATION PANEL BOX CORNER. R3 FINISH
• LIGHTS THE DOOR OPEN BUTTON WHEN THE
CONTROL OPERATION IS COMPLETED
NOTES:
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:5
A M
A-A725
C A
R O
P E
R A
T
IN
G P
A N
E L
D E
S
IG
N D
R A
W
IN
G
A P
O A
P
-5
K .E
L L
IN
G W
O O
D
I.
R
O L L O
J .M
A N
U
IA
D .M
O A
T S
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
60 120
1 : 3A1
CAR OPERATING PANEL
SCALE: 1 : 3
B O
X H
E
IG
H T
BOX DEPTH
90 3
.5
.5
E Q
E Q
ACCESS
R3
UP
OFF
DOWN
ACCESS SWITCH
A .F
.F
(2) M4 HEX SOCKET SCREWS
(M4 COUNTERSUNK)
H A
IR
L
IN
E D
IR
E
C T
IO
N
ACCESS SWITCH FOR 1ST AND 2ND FLOORS
CHAMFER
27.5 50 27.5
7.5 105 7.5
60 60
4-8 DIA X 16L OBLONG HOLE
(BOX TOP AND BOTTOM)
CHAMFER
SPECIFICATION
FACE PLATE
LETTER
ACCESS SWITCH
STAINLESS STEEL HAIRLINE FINISH
SILK PRINTING BLACK TEXT
IDEC HA1K-33C2D KEY NO. 231
AUTOMATIC RETURN METHOD
• OFF: KEY MISSING
• UP: NO KEY MISSING
• DOWN: NO KEY MISSING
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:5
A M
A-A726
A C
C E
S S
S W
IT
C
H D
R A
W
IN
G
A P
O A
P
-5
K .E
L L
IN
G W
O O
D
I.
R
O L L O
J .M
A N
U
IA
D .M
O A
T S
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
SCALE: 1 : 2
40 80
1 : 2A1
ACCESS SWITCH DETAIL
62 1.5
EMERGENCY
PHONE
PULL TO OPEN
EMERGENCY PHONE
SOLID LIGHT: CALLING
BLINKING LIGHT: RECEIVED
RATH
OPERATION
INDICATOR LIGHT
CALL BUTTON
FACE PLATE
COVER
CAUTION
FOR ELEVATOR TROUBLE,
PUSH THE BUTTON
FOR EMERGENCIES ONLY
注 意 エレベータートラブルの際は、
ボタンを押してください 非常時連絡専用
INTERCOM INFORMATION BOARD
1 SET
.5
.5
7.5 185 7.5
SPECIFICATION
NAMEPLATE BODY
LETTER
MOUNTING POSITION
STAINLESS STEEL HAIRLINE FINISH
SILK PRINTING BLACK TEXT
(ROUND GOTHIC FONT)
UPPER PART OF INTERCOM
SPECIFICATION
PHONE MODEL NAME
REMARKS
2100-958SSC2 (RATH)
WITH PUSH BUTTON COVER
DEDICATED TELEPHONE
1 SET
19 165 19
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:5
A M
A-A727
D E
D
IC
A T
E D
P H
O N
E C
A U
T
IO
N N
A M
E P
L A
T E
D E
S
IG
N D
R A
W
IN
G
A P
O A
P
-5
K .E
L L
IN
G W
O O
D
I.
R
O L L O
J .M
A N
U
IA
D .M
O A
T S
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
SCALE: 1 : 1
20 40
1 : 1A1
DEDICATED PHONE CAUTION NAMEPLATE
.2
171.45
170.18 45
ELEVATOR COMMUNICATIONS FAILURE
OPERATION
INDICATOR LIGHT
KEY SWITCH
ELEVATOR EMERGENCY COMMUNICATION SYSTEM MALFUNCTION INDICATOR LIGHT
1 SET
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:5
A M
A-A728
E L
E V
A T
O R
C O
M M
U N
IC
A
T
IO
N S
F A
IL
U
R E
D E
S
IG
N D
R A
W
IN
G
A P
O A
P
-5
K .E
L L
IN
G W
O O
D
I.
R
O L L O
J .M
A N
U
IA
D .M
O A
T S
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
SCALE: 1 : 1
20 40
1 : 1A1
ELEVATOR COMMUNICATIONS
ELEVATOR
CONTROLLER
INVERTER
AC 3-PHASE
POWER SUPPLY
CONTROL PANEL
SPEED
FEEDBACK
INDUCTION
MOTOR
PULSE
ENCODER
TRACTION
MACHINE
SHEAVE
ROPE ROPE
HALL POSITION INDICATOR
CAR OPERATION INDICATOR
COUNTER WEIGHT
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:5
A M
A-A729
S Y
S T
E M
D
IA
G R
A M
A P
O A
P
-5
K .E
L L
IN
G W
O O
D
I.
R
O L L O
J .M
A N
U
IA
D .M
O A
T S
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
SCALE: 1 : 1
20 40
1 : 1A1
SYSTEM DIAGRAM
EARTHQUAKE
地 震 発 生
DID P-WAVE SENSOR OPERATE?
P波センサーは作動したか
NO
いいえ
YES
はい
ELEVATOR REMAINS OPERATIONAL
平 常 運 転
EARTHQUAKE
地震の発生を表示灯とアナウンスで知らせる
OPERATE VISUAL & AUDIBLE SIGNAL
EARTHQUAKE
エレベーターは最寄階へ到着し戸開後、 照明は消灯する(戸開は継続する)
CAR STOPS AT NEAREST LANDING
AND DOOR KEEP OPEN
DID S-WAVE (2ND STAGE)SENSOR
OPERATE?
P波センサーは作動したか
NO
いいえ
YES
はい
ELEVATOR REMAINS STOPPED
運 転 休 止
CALL MAINTENANCE COMPANY
保守会社に連絡
P波センサーが無感になり
一定時間後平常運転に自動復帰
ELEVATOR RESUMES OPERATION AFTER
THE P-WAVE SENSOR RESETS AND THE
GIVEN TIME PASSES
【P波センサーの設定値】
S波(低)センサーの設定値 200ガル S波(高)センサーの設定値 300ガル
地震による停電で地震加速度が300ガルを超えた場合は乗客の安全のため停電時自動着床装置は動作しません
SET UP ACCELERATION OF P-WAVE SENSOR
SET UP ACCELERATION OF S-WAVE (2ND STAGE) SENSOR 200 GAL (LOW), 300 GAL (HIGH) AT THE
TIME OF POWER FAILURE BY EARTHQUAKE AND THE ACCELERATION IS MORE THAN 300 GAL,
AUTOMATIC STOPPING SYSTEM WILL NOT WORK FOR THE PASSENGER'S SAFETY.
PRIMARY-WAVE SENSING EARTHQUAKE EMERGENCY RETURN OPERATION
1.P波地震時管制運転の動作フロー
EMERGENCY LANDING DEVICE
2.停電時自動着床装置の動作フロー
POWER FAILURE / TROUBLE
停電・故障発生
自動的に安全を確認し異常が
無ければバッテリーに切り替える
AUTOMATICALLY CHECK ELEVATOR
CONDITION SWITCH OVER TO BATTERY
OPERATION
POWER FAILURE
停電である事を表示灯とアナウンスで
知らせる
停電で天井照明が消灯すると
停電灯が点灯
POWER FAILURE
OPERATE VISUAL AND AUDIBLE SIGNAL
CEILING LIGHTS TURN OFF
EMERGENCY LIGHTS TURN ON
エレベーターは最寄階へ到着し 自動的に戸開後その状態を保つ
CAR STOPS AT NEAREST LANDING AND
DOORS KEEP OPEN
POWER RECOVERY
停 電 復 旧
TROUBLE OTHER THAN OUTAGE
停電以外の故障
RESUMES OPERATION
平 常 運 転
CALL MAINTENANCE COMPANY
保守会社に連絡
AT THE TIME OF POWER FAILURE BY EARTHQUAKE AND THE ACCELERATION IS MORE THAN 300 GAL, AUTOMATIC STOPPING SYSTEM WILL NOT WORK FOR THE PASSENGER'S SAFELY.
地震による停電で地震加速度が300ガルを超えた場合は乗客の安全のため停電時自動着床装置は動作しません
FIREFIGHTERS' EMERGENCY OPERATION - PHASE 1
3.消防隊運転の動作フロー PHASE 1
DID FIRE OCCUR?
火災は発生したか?
NO
いいえ
YES
はい
NO
いいえ
IS FIRE RECALL KEY SWITCH TO "ON" POSITION?
FIRE RECALL スイッチがONに回されたか
ELEVATOR REMAINS OPERATIONAL
平 常 運 転
(PHASE 1 OPERATION)
OPERATE VISUAL AND AUDIBLE SIGNAL
火災である事を表示灯とブザーで知らせる
OPERATE VISUAL AND AUDIBLE SIGNAL
火災である事を表示灯とブザーで知らせる
• FE 表示灯が点灯する。
機械室か昇降路から火災信号のときに限り、
点滅する。
• FE OPERATION INDICATOR IS ILLUMINATED.
THE INDICATOR FLASHES ONLY WHEN THE
FIRE ALARM DEVICE IN THAT MACHINE
ROOM OR IN THAT HOISTWAY WAS
ACTIVATED.
NO
いいえ
YES
はい
DID FIRE OCCUR 1ST FLOOR?
火災発生場所は1階か?
GOES DIRECTLY TO THE 2ND FLOOR
エレベーターは2階に直行で向かう
GOES DIRECTLY TO THE 1ST FLOOR
エレベーターは1階に直行で向かう
エレベーターは呼び戻し階へ到着すると戸開し、
「ドアが開いたらエレベーターから降りて下さい」を発報する
(エレベーターは呼び戻し階で戸開中)
OPENS THE DOOR WHEN IT ARRIVES AT THE RECALL FLOOR
THEN, "DING, DING, PLEASE EXIT WHEN THE DOORS OPEN, "ARE ANNOUCED TWICE.
(THE ELEVATOR IS HELD AT THE RECALL FLOOR, AND DOORS REMAIN OPEN.
TO PHASE 2 OPERATION
消防隊運転PHASE2へ
NOTE: THE KEY SHALL BE REMOVABLE ONLY IN THE "OFF" AND "ON" POSITIONS.
備考:キーは「OFF及び」「ON」の位置でのみ取外しできる。
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:5
A M
A-A730
E M
E R
G E
N C
Y O
P E
R A
T
IO
N F
L O
W C
H A
R T
A P
O A
P
-5
K .E
L L
IN
G W
O O
D
I.
R
O L L O
J .M
A N
U
IA
D .M
O A
T S
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O
FIREFIGHTERS' EMERGENCY OPERATION - PHASE 2
4.消防隊運転の動作フロー PHASE 2
以下の全ての条件が成立する。
①いずれかのFE-PHASE 1運転開始条件が発生している
②カゴ呼び戻し階に停止していて、戸開中である
③PHASE 2キースイッチがONに回される
ALL OF THE FOLLOWING CONDITIONS OCCUR.
① ANY OF CONDITIONS TO INITIATE FE-PHASE 1 OPERATION OCCURS.
② THE CAR IS AT THE RECALL FLOOR WITH THE DOORS OPEN.
③ PHASE 2 KEY SWITCH IS TURNED TO "ON".
(PHASE 2 OPERATION)
PRESS THE DESIRED FLOOR BUTTON AT CAR CONTROL PANEL. (※)
カゴ内の行先階ボタンを押す(※)
CLOSE THE DOORS BY A CONTINUOUS-PRESSURE OF "CLOSE" BUTTON.
(IF "CLOSE" BUTTON IS RELEASED BEFORE THE DOORS REACHING THE FULLY CLOSE POSITION, IT SHALL AUTOMATICALLY REOPEN.)
CLOSEボタンを押し続け、ドアを完全に閉じる(閉まる途中で指を離すとドアは全開)
THE CAR TRAVELS TOWARD THE FLOOR.
カゴが行先階へ向かう
THE CAR ARRIVES AT THE FLOOR. (THE DOORS REMAIN CLOSED.)
カゴが目的階へ到着する(到着後、ドアは自動で開かず戸閉状態を継続)
OPEN THE DOORS BY A CONTINUOUS-PRESSURE OF "OPEN" BUTTON.
(IF "OPEN" BUTTON IS RELEASED BEFORE THE DOORS REACHING THE FULLY OPEN POSITION. IT SHALL AUTOMATICALLY CLOSE.)
OPENボタンを押し続け、ドアを全開する(開く途中で指を離すとドアは全閉)
WHEN PHASE 2 KEY SWITCH IS TURNED TO "HOLD" POSITION, THE CAR SHALL REMAIN AT THE FLOOR WITH THE DOORS OPEN.
カゴ内の2次消防キースイッチをHOLDに回すと、ドアは開いた状態を継続する。
RESCUE
救 助 活 動
WHEN PHASE 2 KEY SWITCH IS TURNED TO "OFF" POSITION, THE DOORS CLOSE AUTOMATICALLY, AND THE CAR GOES TO THE RECALL FLOOR AS PHASE 1 OPERATION.
カゴ内の2次消防キースイッチをOFFに回すと、1次消防運転に戻り、ドアは自動で閉まって呼び戻し階に直行する。
※ 登録されたカゴ呼びは、CALL CANCELボタンを押すとキャンセルされます。
走行中にこの操作が行われた場合、カゴは最寄階に停止します。.
※ REGISTERED CAR CALLS ARE CANCELLED WHEN "CALL CANCEL" BUTTON IS PRESSED.
IF THE CAR IS TRAVELING, IT STOPS BEFORE OR AT THE NEXT AVAILABLE FLOOR.
SPRINKLER EMERGENCY OPERATION
5.スプリンクラー管制運転の動作フロー
ANY OF SPRINKLER IN MACHINE ROOM OPERATION
エレベーター機械室のスプリンクラーが作動する
THE ELEVATORS CUT THE POWER SUPPLY
エレベーターは電源を遮断する
NFB OFF FOR AUTOMATIC LANDING DEVICE PANEL FOR POWER CUT
EV STOP POWER SUPPLY
EV制御盤ブレーカ OFF 停電時自動着床装置 OFF エレベーター停止
1. 再配置するフロースイッチと監視コントロールバルブをエレベーター機械室の外に設置する。
2. フロースイッチは延滞時間を持たないものとする。
1. RELOCATE EXISTING FLOW SWITCH AND SUPERVISED CONTROL VALVE AT OUTSIDE
OF THE ELEVATOR MACHINE ROOM.
2. THE FLOW SWITCH SHALL HAVE NO TIME DELAY.
NOTE:
備考:
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:5
A M
A-A731
E M
E R
G E
N C
Y O
P E
R A
T
IO
N F
L O
W C
H A
R T
A P
O A
P
-5
K .E
L L
IN
G W
O O
D
I.
R
O L L O
J .M
A N
U
IA
D .M
O A
T S
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O
鏡
RATH
EMERGENCY PHONE
SOLID LIGHT:CALLING
BLINKING LIGHT:RECEIVED
EMERGENCY
PHONE
PULL TO OPEN→
E N
T R
A N
C E
H E
IG
H
T
A P
E R
T U
R E
CAGE INTERIOR
PROTECTIVE CURTAIN
1630 10
120 240 200
NOTCH
460 610
N O
T C
H
PROTECTIVE CURTAIN
1630 10
P R
O T
E C
T
IV
E C
U R
T A
IN
P R
O T
E C
T
IV
E C
U R
T A
IN
H
E
IG
H T
C A
R I N
T E
R
IO
R H
E
IG
H T
CAGE INTERIOR
PROTECTIVE CURTAIN
2480 10
NOTCH
630 925
N O
T C
H
P R
O T
E C
T
IV
E C
U R
T A
IN
P R
O T
E C
T
IV
E C
U R
T A
IN
H
E
IG
H T
C A
R I N
T E
R
IO
R
CAGE INTERIOR
C A
R I N
T E
R
IO
R
P R
O T
E C
T
IV
E C
U R
T A
IN
H
E
IG
H T
PROTECTIVE CURTAIN
1630 10
NOTCH
460 560
E N
T R
A N
C E
H E
IG
H
T
P R
O T
E C
T
IV
E C
U R
T A
IN
P R
O T
E C
T
IV
E C
U R
T A
IN
H
E
IG
H T
C A
R I N
T E
R
IO
R H
E
IG
H T
E N
T R
A N
C E
H E
IG
H
T
IN-CAR TELEPHONE
WARNING SIGN
IN-CAR
PHONE
BASKET PROTECTION
SCREEN (MAGNETIC
TYPE)
WHEELCHAIR OPERATION
PANEL (SECONDARY)
SIDE OF THE CAR (WHEELCHAIR SUB-CONTROL PANEL SIDE) CAR PROTECTION CURTAIN
(MAGNETIC TYPE)
BACK OF BASKET
BASKET PROTECTION SCREEN
(MAGNETIC TYPE)
BASKET PROTECTION SCREEN
(MAGNETIC TYPE)
WHEELCHAIR OPERATION
PANEL (POSITIVE)
SIDE OF THE CAR (FRONT OF WHEELCHAIR CONTROL PANEL)
CAR PROTECTION CURTAIN
(MAGNETIC TYPE)
10 575 10
ENTRANCE / EXIT WIDTH
CAR PROTECTION CURTAIN
(MAGNETIC TYPE)
GENERAL
OPERATION
PANEL
CAR ENTRANCE SIDE
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:5
A M
A-A732
P R
O T
E C
T
IV
E C
U R
T A
IN
I
N S
ID
E
E L
E V
A T
O R
C A
R
A P
O A
P
-5
K .E
L L
IN
G W
O O
D
I.
R
O L L O
J .M
A N
U
IA
D .M
O A
T S
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
240 480
1 : 12A1
PROTECTIVE CURTAIN INSIDE CAR
SCALE: 1:12
RATH
EMERGENCY PHONE
SOLID LIGHT:CALLING
BLINKING LIGHT:RECEIVED
EMERGENCY
PHONE
PULL TO OPEN→
1. EARTHQUAKE! PLEASE EXIT AS SOON AS THE DOOR OPENS. EARTHQUAKE DRIVING GUIDANCE
2. POWER FAILURE! PLEASE EXIT AS SOON AS THE DOOR OPENS. GUIDANCE DURING POWER OUTAGE OPERATION.
3. FIRE! PLEASE EXIST AS SOON AS THE DOOR OPENS. GUIDANCE IN CASE OF FIRE OPERATION.
4. FAILURE! PLEASE CONTACT US BY USING THE EMERGENCY CALL. EMERGENCY INFORMATION
5. GOING UP. DIRECTIONAL GUIDANCE
6. GOING DOWN. DIRECTIONAL GUIDANCE
7. SORRY, OVERLOAD. PLEASE GET OFF THE ELEVATOR OVERBOARDING INFORMATION
8. THE DOOR WILL CLOSE. DOOR CLOSING INFORMATION
9. THE DOOR WILL OPEN. DOOR OPENING GUIDE
10. FIRST FLOOR. FLOOR GUIDE
11. SECOND FLOOR. FLOOR GUIDE
12. CALLING OPERATOR. PLEASE WAIT. INTERCOM CALL NOTIFICATION
VOICE SYNTHESIS GUIDANCE BROADCAST CONTENT
BROADCAST CONTENT CLASSIFICATIONNO.
CAR CEILING SHEET TEEL PAINT FINISH
CAR PANEL STAINLESS STEEL HAIRLINE FINISH
ENTRANCE COLUMN STAINLESS STEEL HAIRLINE FINISH
DOORS STAINLESS STEEL HAIRLINE FINISH
UPPER PANEL STAINLESS STEEL HAIRLINE FINISH
LIGHTING LED CEILING LIGHTING
BASE LIGHT WITH MILKY WHITE ACRYLIC COLOR
EMERGENCY LIGHT 2 LIGHT (BUILT-IN CEILING)
BUILT-IN STORAGE BATTERY LED EMERGENCY LIGHT
KICK PLATE STAINLESS STEEL HAIRLINE FINISH
HANDRAIL STAINLESS STEEL HAIRLINE FINISH
CAR SILL STAINLESS STEEL
CAR FLOOR VINYL TILE FLOOR
ESCAPE HATCH EXISTENCE (600 X 600)
VENTILATION SYSTEM 2-STAGE SWITCHING
SPECIFICATION
STANDARDTYPE
E N
T R
A N
C E
O
P E
N
IN
G
H E
IG
H
T
C E
IL
IN
G H
E
IG
H T
CONTROL PANEL
FOR WHEELCHAIR
HANDRAIL
KICKPLATE
SECTION A SECTION B
C E
IL
IN
G H
E
IG
H T
C E
IL
IN
G H
E
IG
H T
SECTION C
KICK PLATE
HANDRAIL
CONTROL
PANEL FOR
WHEELCHAIR
CAR
EMERGENCY
TELEPHONE
CAUTION SIGN (CAR
EMERGENCY TELEPHONE) 275 200
CAR MAIN
OPERATING
PANEL
E N
T R
A N
C E
O
P E
N
IN
G
H E
IG
H
T
E N
T R
A N
C E
O
P E
N
IN
G
H E
IG
H
T
OPENING WIDTH
KICK PLATE
SECTION D
CAGE FLOOR PLAN CAGE CEILING PLAN
A
B
C
D
C A
R I N
T D
E P
T H
P L A
T F
O R
M D
E P
T H
120 450 860 450 120
CAR INT. WIDTH
2000 30
PLATFORM WIDTH
OPENING WIDTH
CAR FLOOR
(VINYL TILE)
CAR INT. WIDTH
2000 30
PLATFORM WIDTH
C A
R I N
T D
E P
T H
P L A
T F
O R
M D
E P
T H
OPENING WIDTH
LED CEILING LIGHTING CEILING ESCAPE HATCH
(600 X 600)
LED CEILING
LIGHTING
EMERGENCY
LIGHT
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:5
A M
A-A733
C A
R D
E S
IG
N
D E
T A
IL
A P
O A
P
-5
K .E
L L
IN
G W
O O
D
I.
R
O L L O
J .M
A N
U
IA
D .M
O A
T S
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
SCALE: 1 : 20
400 800
1 : 20A1
ELEVATOR CAR DESIGN
UP BUTTON
1 FL LANDING
HALL LANTERN
2 FL LANDING
HALL LANTERN
DOWN BUTTON
.5
.5
90 3
E Q
E Q
EQ EQ
.5
.5
90 3
E Q
E Q
EQ EQ
7.5 85 7.5
7.5 85 7.5
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:5
A M
A-A734
L A
N T
E R
N I
N T
H E
B O
A R
D
IN
G H
A L
L D
E T
A
IL
A P
O A
P
-5
K .E
L L
IN
G W
O O
D
I.
R
O L L O
J .M
A N
U
IA
D .M
O A
T S
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
SCALE: 1 : 1
20 40
1 : 2A1
LANTERN IN THE BOARDING HALL
101.6
.6
101.6
.6
FLOOR DISPLAY BOARD (1ST FLOOR) FLOOR DISPLAY BOARD (2ND FLOOR)
1 2
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:5
A M
A-A735
F L
O O
R D
IS
P
L A
Y B
O A
R D
S
A P
O A
P
-5
K .E
L L
IN
G W
O O
D
I.
R
O L L O
J .M
A N
U
IA
D .M
O A
T S
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
SCALE: 1 : 1
20 40
1 : 1A1
FLOOR DISPLAY BOARD DESIGN
E N
T R
A N
C E
H E
IG
H
T
OPENING WIDTH
1220 50
250 200
5 1
W A
L L O
P E
N
IN
G H
E
IG
H T
100 1180 100
114112
WALL OPENING WIDTH
.5
58 171
73 142
OPENING WIDTH
1220 50
250250
E N
T R
A N
C E
H E
IG
H
T
WALL OPENING WIDTH
W A
L L O
P E
N
IN
G H
E
IG
H T
ACCESS SWITCH
LOBBY
PUSH
BUTTON
2FL HOIST WAY
J
100 1180 100
ACCESS SWITCH
WALL OPENING LOBBY PUSH
BUTTON WALL
OPENING
2FL WALL OPENING
J
J J
ACCESS SWITCH
FIRE BOX
ELEVATOR
COMMUNICATIONS
FAILURE
LOBBY PUSH BUTTON
1FL HOIST WAY
1FL WALL OPENING
ACCESS
SWITCH
WALL
OPENING
LOBBY PUSH BUTTON
WALL OPENING
ELEVATOR COMMUNICATIONS
FAILURE WALL OPENING
FIREBOX WALL OPENING
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:5
A M
A-A736
F R
O N
T E
N T
R A
N C
E W
A L
L O
P E
N
IN
G D
IA
G
R A
M
A P
O A
P
-5
K .E
L L
IN
G W
O O
D
I.
R
O L L O
J .M
A N
U
IA
D .M
O A
T S
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
1 : 15A1
FRONT ENTRANCE WALL OPENING DIAGRAM
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
300 600
SCALE: 1:15
AA
BB
D/B106B
D /B
A
D/B105B
D /B
A
D/B104B
D /B
A
D /B
A
D/B102B
D /B
A
D/B101B
ALPHA
STORAGE
B101
BRAVO
STORAGE
B102
CHARLIE
STORAGE
B103
DELTA
STORAGE
B104
ECHO
STORAGE
B105
HQ
STORAGE
B106
D/B103B
D /B
A
45900
7650 7650 7650 7650 7650 7650
EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ
C1
A-B301
C1
A-B301
I1
A-B301
I1
A-B301
F1
A-B201
K1
A-B201
A1
A-B201
F10
A-B201
DS DS DS DS
D /B
D /B
D /B
D /B
D /B
D /B
B116
HQ CLOSET
B115
ECHO CLOSET
B114
DELTA CLOSET
B113
CHARLIE CLOSET
B112
BRAVO CLOSET
B111
ALPHA CLOSET
1630 1630
1630 1630 1630L /B
B
L /B
B
L /B
B
L /B
B
L /B
B
L /B
B
2000 2000 2000 2000 2000 2000
L/B106A L/B105A
L/B104A L/B103A
L/B101AL/B102A
ABOVEABOVE
ABOVEABOVE
ABOVE ABOVE
EPOXY COATED,
FULL HT EXPANDED
METAL MESH PARTITION
EPOXY COATED,
FULL HT EXPANDED
METAL MESH PARTITION
L /B
C
L /B
C
L /B
C
L /B
C
L /B
C
L /B
C
A1
A-B312
A1
A-B311
A10
A-B311
9 9
3950 3950
1300 1300
3700 3950 3950
1300 1300
3950 3950
1300 1300
1. CONTRACTOR OR RESPONSIBLE PARTY TO FIELD VERIFY
AND CONFIRM ALL DIMENSIONS AND LAYOUT INFORMATION.
NOTIFY DESIGNER OF ANY CONFLICTS OR DISCREPENCIES
PRIOR TO CONSTRUCTION.
2. DO NOT SCALE DRAWINGS.
3. DIMENSIONS MARKED "CLR" ARE FROM FINISH FURFACE TO
FINISH SURFACE.
4. SEE STRUCTURAL DRAWINGS FOR CONCRETE WALL
THICKNESSES.
1 : 100A1
OS - OVERALL FLOOR PLAN (CLIN 0002)
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:5
A M
A-B101
O S
F
L O
O R
P L A
N
C L
IN
A P
O A
P
-5
K .E
L L
IN
G W
O O
D
I.
R
O L L O
J .M
A N
U
IA
D .M
O A
T S
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
AREA - GSF - ORG STORAGE
BUILDING AREA (SM) AREA (SF)
ORGANIZATIONAL STORAGE 552 m² 5946 ft²
PLAN
NORTH
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
SCALE: 1 : 100
2000 4000
INT
ELEV
KEY
A
D B
C
GENERAL NOTES
GRAPHIC SCALE
CLIN 0002
1. ALL ITEMS INDICATED ON REFLECTED CEILING PLAN ARE
SHOWN IN DESIRED LOCATIONS. COORDINATE RELATED
WORK TO AVOID CONFLICTS AND ASSURE COMPLIANCE
WITH CONTRACT DOCUMENTS AND THE DESIGN INTENT.
ANY CONFLICTS SHALL BE BROUGHT TO THE ATTENTION
OF THE CONTRACTING OFFICER BEFORE WORK
PROCEEDS.
2. REFER TO MECHANICAL, ELECTRICAL, AND FIRE
PROTECTION FOR DIFFUSERS, LIGHT FIXTURE, ALARM
SPEAKER, AND OTHER CEILING ELEMENTS.
1. PRIMARY ROOFING TO BE FLUID APPLIED ELASTOMERIC
ROOFING.
2. ROOFING SUBCONTRACTOR TO VERIFY ALL DIMENSIONS
AND CONDITIONS ON SITE.
3. ALL SPOT ELEVATIONS ON PLAN INDICATE THE
APPROXIMATE ROOF SURFACE U.N.O. AND ARE BASED ON
FINISH FLOOR HEIGHT OF 0MM.
4. ROOF SLOPE SHALL MAINTAIN SLOPE AS NOTED OVER THE
ENTIRE ROOF AREA.
5. ROOF GUTTERS SHALL MAINTAIN A MINIMUM 0.5:10 SLOPE
TO ROOF DRAINS.
6. PAINT ALL ROOF TOP EQUIPMENT, ACCESSORIES AND
PENETRATIONS TO MATCH ROOF.
7. REFER TO ELECTRICAL FOR LIGHTING PROTECTION LAYOUT.
8. REFER TO REFLECTED CEILING PLANS FOR CONCRETE
EYEBROW DIMENSIONS.
9. PROVIDE PERMANENT ROOF ANCHOR FALL ARREST SYSTEM
AS REQUIRED PER OSHA. CONTRACTOR TO RETAIN A
COMPANY SPECIALIZING IN FALL PROTECTION SYSTEMS TO
DESIGN, SUPPLY, INSTALL, AND CERTIFY THE ROOF ANCHOR
FALL ARREST SYSTEM.
AA
BB
C1
A-B301
C1
A-B301
I1
A-B301
I1
A-B301A1
A-B201
F10
A-B201
RDHPRDHPRDHPRD
FLUID APPLIED ROOFING
SYSTEM ON CONC, TYP.
INTEGRATED CONC GUTTER
W/ 0.5% MIN SLOPE, TYP.
WALLS BELOW,
TYP.
A-06
A-06
.2
S
L
O
H
O H
OH
1000 46350
OH
AA
BB
C1
A-B301
C1
A-B301
I1
A-B301
I1
A-B301
HQ
STORAGE
B106
ECHO
STORAGE
B105
DELTA
STORAGE
B104
CHARLIE
STORAGE
B103
BRAVO
STORAGE
B102
ALPHA
STORAGE
B101
O.T.S. O.T.S. O.T.S. O.T.S. O.T.S. O.T.S.
B116
HQ CLOSET
B115
ECHO CLOSET
B114
DELTA CLOSET
B113
CHARLIE CLOSET
B112
BRAVO CLOSET
B111
ALPHA CLOSET
O.T.S. O.T.S. O.T.S. O.T.S. O.T.S. O.T.S.
OPEN TO SLAB
LIGHTING FIXTURES,
SEE ELEC DWGS
1 : 100I1
OS - ROOF PLAN (CLIN 0002)
1 : 100A1
OS - REFLECTED CEILING PLAN (CLIN 0002)
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:0
A M
A-B102
O S
R
O O
F P
L A
N A
N D
R E
F L
E C
T E
D C
E
IL
IN
G
P L
A N
C
L
IN
A P
O A
P
-5
K .E
L L
IN
G W
O O
D
I.
R
O L L O
J .M
A N
U
IA
D .M
O A
T S
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
PLAN
NORTH
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
SCALE: 1 : 100
2000 4000
INT
ELEV
KEY
A
D B
C
GENERAL NOTES - RCP
GRAPHIC SCALE
GENERAL NOTES - ROOF PLAN
CLIN 0002
LEGEND
AIR BARRIER, SEE NOTE BELOW
PROVIDE CONTINUOUS AIR BARRIER FOR THE ENTIRE
EXTERIOR BUILDING ENVELOPE. SEE DETAIL A-104 FOR
TYPICAL AIR BARRIER DETAILS INCLUDING TRANSITIONS,
JOINTS, AND PENETRATIONS. AIR BARRIER
COMPONENTS AND ASSEMBLIES ARE AS FOLLOWS:
ROOF ASSEMBLIES
FLUID APPLIED ROOFING OVER CONCRETE (AIR
BARRIER). PROVIDE MEMBRANE AIR BARRIER AT ALL
JOINTS AND PENETRATIONS
WALL ASSEMBLIES
1 - SPRAY TILE FINISH OVER CONCRETE (AIR BARRIER).
PROVIDE MEMBRANE AIR BARRIER AT ALL JOINTS AND
PENETRATIONS.
FLOOR ASSEMBLIES
1 - CONCRETE SLAB WITH VAPOR BARRIER (AIR BARRIER)
ON COMPACTED BASE COURSE
1. CONTRACTOR OR RESPONSIBLE PARTY TO FIELD VERIFY
AND CONFIRM ALL DIMENSIONS AND LAYOUT INFORMATION.
NOTIFY DESIGNER OF ANY CONFLICTS OR DISCREPENCIES
PRIOR TO CONSTRUCTION.
2. DO NOT SCALE DRAWINGS.
3. REFER TO SHEET A-104 FOR AIR BARRIER DETAILS
AIR/VAPOR BARRIER, TYP.
ENVELOPE 1 ENVELOPE 2 ENVELOPE 3
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
SCALE: 1 : 300
6000 12000
PLAN
NORTH
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:0
A M
A-B141
O S
A
IR
B
A R
R
IE
R P
L A
N
C L
IN
A P
O A
P
-5
K .E
L L
IN
G W
O O
D
I.
R
O L L O
J .M
A N
U
IA
D .M
O A
T S
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
GENERAL NOTES
GRAPHIC SCALE
LEGEND
AIR BARRIER ENVELOPE AREAS
ORGANIZATIONAL STORAGE:
ENVELOPE 1 13.2 SM
ENVELOPE 2 13.2 SM
ENVELOPE 3 13.2 SM
SCALE: 1 : 200
4000 8000
SCALE: 1 : 100
2000 4000
CLIN 0001-0002
1 : 100A1
OS - AIR BARRIER FLOOR PLAN (CLIN 002)
ALPHA
STORAGE
B101
BRAVO
STORAGE
B102
CHARLIE
STORAGE
B103
DELTA
STORAGE
B104
ECHO
STORAGE
B105
HQ
STORAGE
B106
B116
HQ CLOSET
B115
ECHO CLOSET
B114
DELTA CLOSET
B113
CHARLIE CLOSET
B112
BRAVO CLOSET
B111
ALPHA CLOSET
B104A B103A
B102AB105AB106A
B116 B115 B114 B113 B112
B111
B101A
B106C B105C B104C B103C B102C B101C
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:0
A M
A-B151
O S
S
IG
N
A G
E P
L
(C L
IN
-0
A P
O A
P
-5
K .E
L L
IN
G W
O O
D
I.
R
O L L O
J .M
A N
U
IA
D .M
O A
T S
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
1 : 100A1
OS - SIGNAGE FLOOR PLAN (CLIN 0002)
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
SCALE: 1 : 100
2000 4000
PLAN
NORTH
CLIN 0002
GENERAL NOTES
1. REFER TO A-551 FOR SIGN TYPES, SIGNAGE MOUNTING
TYPES AND NOTES.
2. REFER TO A-651 FOR SIGNAGE SCHEDULE.
GRAPHIC SCALE
FLOOR 1 (ORGS)
CONTROL POINT (ORGS)
AB 1
4% SL
SPRAY TILE FINISH
SYSTEM, TYP.
CONC. REVEAL,
TYP.
FLOOR 1 (ORGS)
CONTROL POINT (ORGS)
1234567
5 OVERHEAD COILING
DOOR, TYP.
ALUMINUM DOOR
AND FRAME, TYP.
FLUID APPLIED
ROOFING SYSTEM
ON CONC. TYP.
SPRAY TILE FINISH
SYSTEM, TYP.
CONC. REVEALS,
TYP.
FLOOR 1 (ORGS)
CONTROL POINT (ORGS)
1 2 3 4 5 6 7
1 ?SPRAY TILE FINISH
SYSTEM, TYP.
FLUID APPLIED
ROOFING SYSTEM
ON CONC. TYP.
LOUVER W/ HOOD
AS SCHED, TYP. 2
MECH EQUIP, SEE
MECH DWGS TYP.
FLOOR 1 (ORGS)
CONTROL POINT (ORGS)
A B
4% SL
SPRAY TILE FINISH
SYSTEM, TYP.
FLUID APPLIED
ROOFING SYSTEM
ON CONC. TYP.
1. SEE SHEET A-200 FOR EXTERIOR FINISH SCHEDULE
2. ALL DOWNSPOUTS SHALL BE PROVIDED WITH BOOTS
1200MM HIGH WITH AIR GAP AND CLEANOUTS. ALL
DOWNSPOUTS SHALL BE CONNECTED TO THE DRAINAGE
SYSTEM. REFER TO CIVIL DRAWINGS.
3. CONTRACTOR OR RESPONSIBLE PARTY TO FIELD VERIFY
AND CONFIRM ALL DIMENSIONS AND LAYOUT INFORMATION.
NOTIFY DESIGNER OF ANY CONFLICTS OR DISCREPENCIES
PRIOR TO CONSTRUCTION.
4. DO NOT SCALE DRAWINGS.
5. DIMENSIONS MARKED "CLR" ARE FROM FINISH SURFACE TO
FINISH SURFACE
6. SEE STRUCTURAL DRAWINGS FOR CONCRTE WALL
THICKNESSES
1 : 100F1
OS - EXTERIOR ELEVATION - EAST (CLIN 0002)
1 : 100K1
OS - EXTERIOR ELEVATION - NORTH (CLIN 0002)
1 : 100A1
OS - EXTERIOR ELEVATION - SOUTH (CLIN 0002)
1 : 100F10
OS - EXTERIOR ELEVATION - WEST (CLIN 0002)
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:1
A M
A-B201
O S
E
X T
E R
IO
R
E L E
V A
T
IO
N S
C
L
IN
A P
O A
P
-5
K .E
L L
IN
G W
O O
D
I.
R
O L L O
J .M
A N
U
IA
D .M
O A
T S
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
SCALE: 1 : 100
2000 4000
GENERAL NOTES
GRAPHIC SCALE
CONTROL POINT (ORGS)
TOF (ORGS)
-600
A B
OPEN OPEN
CHARLIE
CLOSET
B113
B103
CHARLIE STORAGE
4.3% SLOPE
AIR/VAPOR BARRIER, TYP.
FLOOR 1 (ORGS)
CONTROL POINT (ORGS)
1 2 3 4 5 6 7
ALPHA
STORAGE
B101
BRAVO
STORAGE
B102
CHARLIE
STORAGE
B103
DELTA
STORAGE
B104
ECHO
STORAGE
B105
HQ
STORAGE
B106
1. CONTRACTOR OR RESPONSIBLE PARTY TO FIELD VERIFY
AND CONFIRM ALL DIMENSIONS AND LAYOUT INFORMATION.
NOTIFY DESIGNER OF ANY CONFLICTS OR DISCREPENCIES
PRIOR TO CONSTRUCTION.
2. DO NOT SCALE DRAWINGS.
3. DIMENSIONS MARKED "CLR" ARE FROM FINISH SURFACE TO
FINISH SURFACE.
4. SEE STRUCTURAL DRAWINGS FOR CONCRETE WALL
THICKNESSES.
5. REFER TO SHEET A-101 TO A-103 FOR AIR BARRIER PLANS.
1 : 50I1
OS - BUILDING SECTION - B4.3 (CLIN 0002)
1 : 100C1
OS - BUILDING SECTION - BA.5 (CLIN 0002)
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:1
A M
A-B301
O S
B
U
IL
D
IN
G S
E C
T
IO
N S
C
L
IN
A P
O A
P
-5
K .E
L L
IN
G W
O O
D
I.
R
O L L O
J .M
A N
U
IA
D .M
O A
T S
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
SCALE: 1 : 100
2000 4000
SCALE: 1 : 50
1000 2000
GENERAL NOTES
GRAPHIC SCALE
CONTROL POINT (ORGS)
TOF (ORGS)
-600
A
BOLLARDS,
TYP.
PCC PAVEMENT,
SEE CIVIL DWGS
CONC SLAB OVER
VAPOR BARRIER ON
GRANULAR FILL, SEE
STRUCT DWGS, TYP.
DOOR AS SCHED
CONC WALL, SEE
STRUCT DWGS,
TYP.
COLUMN BEYOND
A-531
E13
4.2% SL
A-515
I1
A-515
M9
A-515
I9
1000 225
CONC FOOTING, SEE
STRUCT DWGS, TYP.
A-532
L8
EPOXY COATED, FULL
HT EXPANDED METAL
MESH PARTITION
FLOOR 1 (ORGS)
CONTROL POINT (ORGS)
TOF (ORGS)
-600
CONC WALL, SEE
STRUCT DWGS,
TYP.
PCC PAVEMENT,
SEE CIVIL DWGS
CONC SLAB OVER
VAPOR BARRIER ON
GRANULAR FILL, SEE
STRUCT DWGS, TYP.
FLUID APPLIED
ROOFING SYSTEM
ON CONCA-532
L14
HQ
STORAGE
B106
1000 225
CONC FOOTING, SEE
STRUCT DWGS, TYP.
1. CONTRACTOR OR RESPONSIBLE PARTY TO FIELD VERIFY
AND CONFIRM ALL DIMENSIONS AND LAYOUT INFORMATION.
NOTIFY DESIGNER OF ANY CONFLICTS OR DISCREPENCIES
PRIOR TO CONSTRUCTION.
2. DO NOT SCALE DRAWINGS.
3. DIMENSIONS MARKED "CLR" ARE FROM FINISH SURFACE TO
FINISH SURFACE.
4. SEE STRUCTURAL DRAWINGS FOR CONCRETE WALL
THICKNESSES.
5. REFER TO SHEET A-101 TO A-103 FOR AIR BARRIER PLANS.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
E M
F
A R
C H v2
.r v t
/1
/2
:2
:1
A M
A-B311
O S
W
A L L S
E C
T
IO
N S
C
L
IN
A P
O A
P
-5
D e s ig n e r
A u th o r
C h e c k e r
IN
T
E R
M E
D
IA
T E
D E
S
IG
N
F Y
M
C A
P N
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
1 : 25A1
OS - WALL SECTION 1 (CLIN 0002)
1 : 25A10
OS - WALL SECTION 2 (CLIN 0002)
ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN
CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS
OTHERWISE NOTED.
SCALE: 1 : 100
2000 4000
GENERAL NOTES
GRAPHIC SCALE
CONTROL POINT (ORGS)
TOF (ORGS)
-600
B
LOUVER W/ SST
HOOD AS SCHED
CONC WALL, SEE
STRUCT DWGS,
TYP.
CONC PAVEMENT,
SEE CIVIL DWGS
4.2% SL
A-532
G1
HQ
CLOSET
B116
HQ
STORAGE
B106
225 1000
DOOR AS SCHED
FLR FIN AS SCHED
BATT INSULATION AT
UNDERSIDE OF CONC ROOF
A-531
H18
1. CONTRACTOR OR RESPONSIBLE PARTY TO FIELD VERIFY
AND CONFIRM ALL DIMENSIONS AND LAYOUT INFORMATION.
NOTIFY DESIGNER OF ANY CONFLICTS OR DISCREPENCIES
PRIOR TO CONSTRUCTION.
2. DO NOT SCALE DRAWINGS.
3. DIMENSIONS MARKED "CLR" ARE FROM FINISH SURFACE TO
FINISH SURFACE.
4. SEE STRUCTURAL DRAWINGS FOR CONCRETE WALL
THICKNESSES.
5. REFER TO SHEET A-101 TO A-103 FOR AIR BARRIER PLANS.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
O
3 5 7 9 11 13 15 17 19
L
J
I
G
C
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
D
B
W
H
V -1
-D
-0
D E
S
IG
N P
A R
T N
E R
S I N
C O
R P
O R
A T
E D
M
A K
A L O
A S
T R
E E
T S
U
IT
E
H O
N O
L U
L U
H
A W
A
II
J A
P A
N E
N G
IN
E
E R
D
IS
T R
IC
T
O K
IN
A
W A
A R
E A
O F
F
IC
E A
P O
A P
-5
E
F
A
N
A u to d e s k D o c s:
S
S F
M J
E D
I D
C V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
/5 T
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .