Source Sought Notice.1707354037753.docx

DOCX document 23 KB Posted

Attached to
Monitoring and Maintenance of Irrigation System at Sarasota National Cemetery
Solicitation number
36C78624Q50109
Issued by

About this file

This market research notice seeks information from suppliers for a potential future solicitation to provide 24-hour remote monitoring and preventative maintenance services for three pump systems at the Sarasota National Cemetery. Interested parties are requested to provide company information and details on relevant experience by February 16, 2024. The Department of Veterans Affairs National Cemetery Administration intends to use responses to determine qualified sources and their small business classifications prior to potentially issuing a solicitation under NAICS 333914, Measuring, Dispensing, and Other Pumping Equipment Manufacturing. The scope of work would include remote monitoring and two annual preventative maintenance visits for each of three pump systems, testing and servicing various pump components.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Please note that this is NOT a request for quotes or proposals, the Government is seeking information for market research purposes only. The Department of Veterans Affairs, National Cemetery Administration (NCA) is conducting a market survey for interested vendors capable of providing “24-hour Remote Monitoring of the Irrigation and Pump System,” at the Sarasota National Cemetery located at 9810 State Rd 72, Sarasota, FL 34241.

The scope of work consists of the following:

Contractor shall provide 24-hour remote monitoring of the irrigation and pump system combined with 2 preventative maintenance visits to the site per year by a certified technician (Hoover Technician) on three (3) pump systems.

Site ID
Site Name
Model #
6539
Sarasota National Cemetery 08-153-6539
HC2F-50J15PDV-460/3-HMSR3L-Z
7059
Sarasota National Cemetery Refill Station
HSPRF-20CS-460/3-MR3W-Z
7333
Sarasota National Cemetery North Pump
HC2-75J15PDV-460/3-HMSR3L-Z

Preventative maintenance will be furnished for each pump system (3) as required:

· Priority Scheduling - When repair service is required.

· Pump Control Panel - Test control logic, torque electrical connections to specification, treat components with anti-oxidant protective spray, test and replace surge protection components.

· Variable Frequency Drive(s) (if applicable) - Test and confirm proper operation. Change 4. Pump motor(s) - Service bearings, check operation and current draw against specification.

· Pump(s) - Check condition of seal. Confirm flow and pressure performance.

· Air Conditioner (if applicable) - Check and confirm proper operation. Clean filter.

· Control Valve (if applicable) - Check pilots and service. Clean filter. Calibrate valve and replace worn diaphragm if required.

· Flow Meter (if applicable) -Test flow meter and pressure transducer for proper operation.

· Calibrate flow meter as required by Florida Water Management District upon client request.

· Pressure Tank (if applicable) - Check and adjust tank pre-charge pressure as required.

· Suction Intake (if applicable) - Evaluate intake performance and recommend screen cleaning as

· Fiberglass Enclosure (if applicable) - Check lockable handle, hinges and opening mechanism.

· Disc-Filter cleaning

· Report - To be submitted upon completion of service call with findings and recommendations.

In response to this announcement, please complete the information below and return to Charnell.Cunningham@va.gov by February 16, 2024 at 10:00 a.m. EST.

Company Name:

Address:

Contact Name:

Phone No:

Email:

Cage Code and/or SAM Unique ID:

Business size information

Select all that applies:

☐ Small Business ☐ Emerging Small Business ☐ Small Disadvantaged Business ☐ Certified under Section 8(a) of the Small Business Act ☐ HubZone ☐ Woman Owned ☐ Certified Service-Disabled Veteran Owned Small in Vetbiz.gov ☐ Certified Veteran Owned Small Business in Vetbiz.gov ☐ Large Business ☐ Other:

FSS/ GSA Contract Holder
Yes ☐ No ☐
FSS/ GSA Contract Number
Effective Date / Expiration Date
Identify any other companies owned (wholly or in-part) by the owners of this business who provide goods or services under the same or a related NAICS codes.
Not applicable ☐

Comment:

Identify any other companies owned (wholly or in-part) by the owners of this business who provide goods or services that are registered under the same or a related NAICS code with the Center for Veterans Enterprise (CVE); Provide the certification type (SDVOSB/VOSB), Federal Identification Number, and state of incorporation for each.
Not applicable ☐

Comment:

Do you plan on responding to a solicitation for this requirement with a Joint Venture utilizing multiple owned companies as majority or non-majority owner?
Yes ☐ No ☐

If yes, please identify which companies are considering a Joint Venture and the ownership of each company.

Are you currently licensed and qualified to provide the following services?
Have you provided this service in the past 3 years?

NAICS: 333914 - Measuring, Dispensing, and Other Pumping Equipment Manufacturing

Yes ☐ No ☐
Yes ☐ No ☐

Contract Number:

Will there be any subcontracting?
Yes ☐ No ☐

Vendor Name:

Cage Code and/or SAM Unique ID:

The purpose of this synopsis is to gain knowledge of potential qualified sources and their size classification (HUBZone, 8(a), small, small disadvantage, veteran owned small business (VOSB), service-disabled veteran owned small business (SDVOSB), or large business) relative to: NAICS 333914, Measuring, Dispensing, and Other Pumping Equipment Manufacturing, with size standards of 750 employees.

Note that if VA’s pending market research establishes that two or more SDVOSB or VOSB, who are certified on SBA’s VetCert, Veteran Small Business Certification (sba.gov), can perform the project at a fair and reasonable price, VA will set aside the underlying solicitation per 38 U.S.C. §8127.

Responses to this synopsis will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Synopsis, a solicitation announcement may be published on SAM.gov and/or GSA eBuy. Responses to this Sources Sought Synopsis are not considered adequate responses to the solicitation announcement.

This notice is neither a request for competitive proposal nor solicitation of offerors. This notice is to assist the NCA in determining sources only and a solicitation is not currently available. If a solicitation is issued it will be announced at a later date, and all interested parties must respond to that solicitation announcement separately from this response. Responses to this Sources Sought Synopsis is not a request to be added to a prospective bidders list or to receive a copy of the solicitation. Information received as a result of this notice will normally be considered solely for the purpose of determining whether to conduct a competitive procurement. This notice does not represent a commitment by the Government to pay for costs incurred in the preparation and submission of information or any other costs incurred as a response to this announcement. Inquiries will only be accepted in writing via email to Charnell.Cunningham@va.gov by February 16, 2024 at 10:00 a.m. EST.

File details come from the government source that posted it. Updated .