SoN - 22 LRS - X-Ray Machine 17 June 2025.pdf
PDF 148 KB Posted
- Attached to
- 22 LRS X-Ray Machine - McConnell AFB
- Solicitation number
- FA462125Q0051
About this file
This Statement of Need outlines requirements for a new X-ray machine for the 22nd Logistics Readiness Squadron (LRS) at McConnell Air Force Base in Kansas. The machine must screen carry-on and checked luggage for airlift operations, meeting United States Transportation Command (USTRANSCOM) and Air Mobility Command (AMC) passenger baggage screening requirements. Key technical specifications include a minimum tunnel size of 30.6" wide by 22.8" high, dual or multi-view imaging capability, material discrimination technology, and storage capacity of at least 256 GB.
Critical requirements include TSA certification, compliance with FDA radiation health standards, ISO 9001 and 14001 certifications, and compatibility with Astrophysics entry/exit roller tables. The vendor must provide a minimum 1-year warranty with options for up to 5-year extended coverage, complete delivery within 115 calendar days, handle machine assembly and installation, and provide training for up to 10 personnel. The X-ray machine must operate in temperatures between 0°C to 40°C, include threat image protection software, and have specific power supply and electrical requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 22 LRS X-Ray - FA462125Q0051 Questions and Answers.docx | DOCX document | |
| Solicitation - FA462125Q0051.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
17 June 2025
Statement of Need
X-Ray Machine
McConnell AFB, Kansas
1. Overview
1.1 The 22nd LRS requires the purchase of one X-ray machine. The machine will be primarily used for screening all carry-on and checked luggage departing via airlift. The Air Force requires passenger baggage X-Ray machines to ensure passenger service agents are not required to hand search all hand-carried and checked baggage to meet United States Transportation Command (USTRANSCOM) and Air Mobility Command (AMC) passenger baggage screening requirements. Additionally, X-Ray screening technology provides a second level of screening to ensure safety of flight on military and commercial aircraft.
2.Tunnel Size Requirements:
2.1 Machine must have a minimum tunnel size of 30.6” inches wide by 22.8” inches high.
2.2 Machine tunnel conveyor must have a weight load/capacity of 364 pounds (minimum 250 pounds).
3. Technology and Environmental Characteristic Requirements:
3.1 Machine must have Material Discrimination Capability as listed in the TSA ACSTL.
3.2 Machine must be either dual or multi-view. Single view will not be accepted.
3.3 Machine must have a wire resolution up to: Standard 38 AWG or Typical 40 AWG
3.5 Machine operating temperature must be between 0°C to 40°C / 32°F to 104°F.
3.6 Machine must be able to be stored in temperatures between -20°C to 60°C / -4°F to 140°F.
3.7 Machine display type must include dual monitors/screens.
3.8 Machine video and image storage capacity must be able to store no less than 256 GB.
3.9 Machine features must include 3 and 6 color imaging, black and white imaging, enhanced imaging, organic and inorganic imaging.
3.10 Machine must include threat image protection software and screener assist software.
4. Electrical/Power Requirements:
4.1 Machine must include an Uninterruptible Power Supply (UPS)
4.2 Machine system power needs to be 110 VAC +/- 10% 50/60Hz, 20 Amp Max and
220 VAC +/- 10% 50/60Hz, 15 Amp Max.
5. Maintenance Requirements:
5.1 Machine's respective vendor must have some maintenance support entity (can either be contracted or vendor owned).
6. Health and Safety Certification Requirements:
6.1 Machine must be TSA Certified and listed on the TSA Air Cargo Screening Technology List (ACSTL).
6.2 Machine must be compliant with USFDA Center for Devices and Radiation Health Standards for Cabinet X-Ray Systems (21-CFR 1020.40).
6.3 Machine must produce typical radiation leakage is less than 0.1 mR/hr (Leakage less than 0.5 mR/hr permitted by U.S. Federal Standards).
6.4 Machine must be certified ISO 9001 and 14001.
7. Compatibility Requirements:
7.1 X-Ray machine must be compliant and be able to connect to Astrophysics entry/exit roller tables.
8. Warranty:
8.1 The vendor shall provide a minimum of 1 year warranty (includes all labor, parts, shipping and travel). Any defect that is not caused by government damage or misuse shall be replaced by the vendor at no cost to the government.
8.2 The vendor shall offer extended warranty plans for up to 5 years (includes all labor, parts, shipping and travel). Any defect that is not caused by government damage or misuse shall be replaced by the vendor at no cost to the government.
9. Delivery and Installation Requirements:
9.1 The vendor or contractor shall complete delivery to McConnell AFB Passenger Terminal no later than 115 calendar days after receipt of the order.
9.2 Vendor or contractor must handle assembly and installation of the machines to include assistance with placement and securement of roller tables.
9.3 Vendor or contractor must provide standard training for up to 10 personnel.
File details come from the government source that posted it. Updated .