STORM WATER RETENTION BASIN
ATCT
PARKING LOT
A T
C T
A
C E
S S
R O
A D
ASPHALT ROAD WAY
SWALE
DUMPSTER PAD
BLDG
UPS
BASE BUILDING
WAY
DRIVE
P A
R K
IN
G
SCREEN
PATIO
L E
A
H
F
IE
L D
30 0 30 60 X
X
X
X
X
X
X
X
X
X
X X X X X X X X X
XXXXXXXXXXXXXXXXXXXXXXXXX
EXISTING FENCE
XXXXXXXXXXXXXXXXXXXXXXX
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
XXXXXXXXXXXXXXXXXXXXXX
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
LUMINAIRE SCHEDULE
Symbol Label Qty File Lumens LLF WattsCatalog Number Description Lamp
A 10 Ltl8505.IES 29000 310
B 1 Ltl8506.IES 50000 468
C 0 94090802.IES 16000 1.00 378
D 5 94121702.IES 6300 1.00 94
FLAT GLASS LENS
ET-18 HIGH PRESSURE
SODIUM, HORIZONTAL
POSITION.
ET-18 HIGH PRESSURE
SODIUM, HORIZONTAL
POSITION.
KSF1 150S R2
ARM MOUNTED FIXTURE
WITH PREMIUM
SEGMENTED OPTICS
ET-23.5 HIGH
PRESSURE SODIUM,
HORIZONTAL POSITION.
TWP 70S
GENERAL PURPOSE
BUILDING MOUNTED
LUMINAIRE, 70W HPS,
W/ CLEAR LAMP.
ONE 70-WATT CLEAR ED-
-17 HIGH PRESSURE
SODIUM, HORIZONTAL
POSITION.
DUAL 150-WATT CLEAR
E
E
E
DUAL POLE MOUNT
EXISTING
SINGLE POLE MOUNT
EXISTING
WALL PACK
EXISTING
N
X X
A
A
A
SEE DRAWING E02 NEW FENCE
EXISTING FENCE
A
D
D
D
D
D
NOTES
PANEL IN BUILDING.
6. LIGHT PAL'S ON BASE BUILDING SHOULD BE WIRED TO CLOSEST AVAILABLE
5. LIGHT PAL'S ON UPS BUILDING SHOULD BE WIRED TO PANEL IN SIDE BUILDING.
4. ADDITIONAL LIGHTING SHOULD BE INCORPORATED INTO PHOTO CELL.
AVAILABLE. ADDITIONAL SPACES AVAILABLE IN PANEL NPA.
3. EXISTING PARKING LOT LIGHTS ARE ON PANEL NLPA. PANEL HAS TWO SPARES
2. POLE FOUNDATIONS SHALL BE PER DRAWING D06 DETAIL 7.
INCLUDE LOWERING WINCH WHEN ORDERING .FINISH COLOR SHALL BE BRONZE.
AT THE MIDDLE FOR LOWERING (LITHONIA) PART #STSG-25-6-48-DM19-DDB.
1. PROVIDE 25 FOOT SQUARE TAPERED GALVANIZED STEEL POLE HINGED
A
A A
A
A
A
X X
X X
X X X
X
B
GATE
PEDESTRIAN GATE
D
D
D
E D
M
IS
S
U E
D
R
$W
ATERMARK$
$W
ATERMARK$
$W
ATERMARK$
$W
ATERMARK$
$W
ATERMARK$
$W
ATERMARK$
$W
ATERMARK$
$W
ATERMARK$
$W
ATERMARK$
$W
ATERMARK$
ANI-300
FL
ATLANTA IMPLEMENTATION CENTER ATLANTA, GA
NAS IMPLEMENTATION
SITE SECURITY PLAN
SECURITY SYSTEM DESIGN
DAYTONA BEACH INTL AIRPORTDAYTONA BEACH
s o d e .d g n
DRAWING PRODUCED ON ASO REGION MICROSTATION SYSTEM
SO-D-100053-E01
JM
MH
SR ENGR, INFRASTRUCTURE PLTFRM MGR, INFRASTRUCTURE PLATFORM
03/06/2007 214105
KSF2 250S R3
VSF2 400S R3
AREA LIGHT WITH
TYPE 3 SHORT,
CUTOFF REFLECTOR,
FLAT GLASS LENS
AREA LIGHT WITH
TYPE 3 SHORT,
CUTOFF REFLECTOR,
250-WATT CLEAR
400-WATT CLEAR
81.
81.
C O
N S
T R
U C
T
IO
N
John M. HerringtonCharles W. Folsom
ORIGINAL DRAWING SIGNED BY: ORIGINAL DRAWING SIGNED BY:
ISSUED
F
IL
E S
D
A T
E
T
IM
E
N
A M
E
A
B
C
D
E
F
G
H
8 7 6 5 4 3 2 1
H
G
F
E
D
C
12345678
REVDRAWING NO
DATE JCN
APPROVED BY
ISSUED BY
CHECKED
DRAWN
DESIGNED
SUBMITTED BY
REVIEWED BY
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV
DATE
APPROVED
DESCRIPTION JCN
DATE
REDLINE
APVD
NOTES
E02
GUARD BOOTH
NOT TO SCALE
C O
U N
T
R
L
IN
E
COUNTER LINE
D O
O R
LAYMENT
UNDER
OVER
TILE
VCT
DOOR
1'-4"
1'-0"
1'-0" C
D
A
B
SERVICE ENTRANCE/ANCHOR BOLT LAYOUT
NOTE: PROVIDE 120/240V 1°-3 WIRE SERVICE WITH GROUND
E02 NOT TO SCALE
POWER PANEL
SEE NOTE 4
#4/0 COUNTERPOISE
E03
GUARD BOOTH
MAG LOOP/PHOTO EYE DETAIL
NOT TO SCALE
PHOTO EYES
PHOTO EYES
SAFETY LOOP
SAFETY LOOP
SEE NOTE 5
SEE NOTE 5
SEE NOTE 5
OPERATOR
GATE
CONTROL WIRING
3/4" CONDUIT FOR
JUNCTION BOX
SEE NOTE 2
HAND HOLD
SEE NOTE 6
CARDREADER PEDESTAL
ROD TO BOOTH STEEL
#2/0 FROM GROUND
OF 4 SEE NOTE 5
PHOTO EYES, TOTAL
GATE MOTOR SEE NOTE 3
CONDUIT FEEDERS TO
GROUND ROD 2 EACH
3/4"x 10' COPPER
POWER AND 1" CONDUIT FOR COMM
EXISTING 2" PVC CONDUIT FOR
E D
M
IS
S
U
D
R
$W
ATERMARK$
$W
ATERMARK$
$W
ATERMARK$
$W
ATERMARK$
$W
ATERMARK$
$W
ATERMARK$
$W
ATERMARK$
$W
ATERMARK$
$W
ATERMARK$
$W
ATERMARK$
ANI-300
FL
JM
MH 03/06/2007 214105
ATLANTA IMPLEMENTATION CENTER ATLANTA, GA
NAS IMPLEMENTATION
GUARD BOOTH ELECTRICAL LAYOUT
CONTROL TOWER
DAYTONA BEACH INTL AIRPORTDAYTONA BEACH
SR ENGR, INFRASTRUCTURE PLTFRM MGR, INFRASTRUCTURE PLATFORM
s o d e .d g n
DRAWING PRODUCED ON ASO REGION MICROSTATION SYSTEM
SO-D-100053-E02
GROUND ROD 2 EACH
3/4" x 10' COPPER
MODEL S3S41243.
6. PEDESTAL AND BACK BOX SHALL BE MANUFACTURED BY PARGON, PHONE NUMBER (818) 882-1638.
BOLLARDS REQUIRED, NOT SHOWN FOR CLARITY.
MANUFACTURERS RECOMMENDATION AND INDUSTRY STANDARD.
MAG LOOPS ARE REQUIRED IN ASPHALT AND WIRED TO MOTOR OPERATOR AS PER THE MOTOR OPERATOR
AS SUCH WIRING WILL BE REQUIRED TO ALL LOCATIONS.
OTHERWISE INSTALL PER MANUFACTURES RECOMMENDATIONS. NOTE THESE ARE TRANSMIT/RECEIVE PHOTO EYES.
ASSOCIATED WIRING SHALL BE RUN UP INSIDE TUBING TO PHOTO CELL. CAP TUBING WITH GALVANIZED CAP.
PHOTO EYES SHALL BE MOUNTED TO GALVANIZED SQUARE TUBING SET IN CONCRETE. MIN SIZE 2".
MODULATED PHOTOCELLS MANUFACTURED BY EMX INDUSTRIES INC. PHONE NUMBER (800) 426-9912.
WITH THE ON SITE CONTRACTING OFFICERS REPRESENTATIVE. PHOTO EYES SHALL BE IRB-325 INFRARED
5. LOCATION OF PHOTO EYES ARE APPROXIMATE. FINAL LOCATION SHALL BE COORDINATED IN THE FIELD
SLAB LEVEL WITH EXTERIOR GROUND LUG. ALL CONNECTIONS BELOW GRADE SHALL BE EXOTHERMIC.
RUN #2/0 BARE FROM COUNTERPOISE UP OVER SLAB AND CONNECT TO STEEL OF BOOTH AT
4. #4/0 COUNTERPOISE AROUND NEW GUARD BOOTH. TWO 3/4" X 10' COPPER GROUND RODS AS SHOWN.
HOUSING USING #6 BSDC IN 1/2" PVC TO GUARD BOOTH COUNTERPOISE.
OPERATOR SHALL BE POWERED FROM PANEL BOARD IN GUARD BOOTH. GROUND OPERATOR
INTO GROUND. CONTRACTOR SHALL SIZE CONDUITS AND WIRING AS NEEDED FOR OPERATOR.
SHALL COME UP THROUGH PAD INTO OPERATOR. NO CONDUITS SHALL RUN OVER SLAB AND DOWN
3. CONCRETE PADS FOR OPERATORS SHALL BE PER DRAWING C06 DETAIL 6. CONDUITS REQUIRED
AS REQUIRED BY SPEC AND CODE
2. CONTRACTOR SHALL PROVIDE HAND HOLD. PAY SPECIAL ATTENTION TO SEPARATION OF COMM/POWER CABLES
ATTENTION TO GROUNDING REQUIREMENTS.
AND ONE CONDUIT IS FOR COMMUNICATION/LOW VOLTAGE. CONDUIT SHALL BE PVC COATED. PAY SPECIAL
1. CONDUITS SHALL RUN BACK TO ATCT AS REQUIRED BY DRAWINGS AND SPECS. ONE CONDUIT IS FOR POWER
3'-11"
D. OUTER EDGE OF BASE
NOT INCLUDED.
BOOTH AFTER FINAL LOCATION. ANCHOR BOLTS
BOLT HOLE 4-REQ'D, ONE EACH CORNER. ANCHOR
C. 3"x 3" x 1/4 " MIN. ANCHOR CLIP WITH 1" ANCHOR
B. 3"x 12" SLOT IN FOR COMMUNICATION SERVICE ENTRANCE.
ENTRANCE TO C.B. PANEL ABOVE
A. 3"x 12" SLOT IN FLOOR FOR ELECTRIC SERVICE
C O
N S
T R
U C
T
IO
N
John M. HerringtonCharles W. Folsom
ORIGINAL DRAWING SIGNED BY: ORIGINAL DRAWING SIGNED BY:
ISSUED
F
IL
E S
D
A T
E
T
IM
E
N
A M
E
A
B
C
D
E
F
G
H
8 7 6 5 4 3 2 1
H
G
F
E
D
C
12345678
REVDRAWING NO
DATE JCN
APPROVED BY
ISSUED BY
CHECKED
DRAWN
DESIGNED
SUBMITTED BY
REVIEWED BY
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV
DATE
APPROVED
DESCRIPTION JCN
DATE
REDLINE
APVD