About this file

The document is a set of drawings and specifications for an audio visual (AV) systems renovation project for the Savannah International Trade and Convention Center (SITCC) in Savannah, Georgia. The project scope includes the installation of new AV infrastructure, equipment, and systems throughout the facility, including meeting rooms, boardrooms, the ballroom, and the Oglethorpe Auditorium. The drawings provide detailed information on the required AV components, cabling, and mounting locations. The project is being procured by the Georgia World Congress Center Authority, which oversees the SITCC facility. The AV bid set was issued on May 1, 2023, and responses are due from specialized AV services firms.

The drawings indicate the AV contractor will be responsible for providing and installing various ceiling and wall-mounted speakers, wall interface plates, control panels, and other AV equipment as specified. The project will be funded through the Authority's capital improvement program, though the specific budget amount is not provided. The project will renovate the existing AV systems and is not expected to have any incumbent AV services provider.

View the file

Other files

File Type Posted
ADDENDUM One June 2024.pdf PDF
Question from previous ADDENDUM 1.pdf PDF
As Built Two.pdf PDF
Audio Visual RFP Savannah July 2024.pdf PDF
Sign in Sheet AV July 2024.pdf PDF
As Built One.pdf PDF
As Built Three.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SUBMITTED ON: MAY 01, 2023

SAVANNAH, GEORGIA 31421

SAVANNAH ITCC - EXISTING FACILITY

AUDIO-VISUAL SYSTEMS

GENERAL NOTES:

A. ELECTRICAL CONTRACTOR TO INSTALL PULL STRINGS IN ALL CONDUIT.

B. ELECTRICAL CONTRACTOR TO TERMINATE ALL CONDUIT STUB-OUT AND SLEEVES WITH PLASTIC BUSHINGS.

C. NO MORE THAN THREE(3) QUARTER BENDS OR 200 DEGREES OF CONDUIT SHALL BE INSTALLED BETWEEN PULL

BOXES.

D. GENERAL CONTRACTOR TO PROVIDE WALL BLOCKING AT ALL FLAT PANEL LOCATIONS.

E. ALL FREE-RUN CABLING SHALL BE SEPARATED BY SIGNAL TYPE. PROVIDE 12" MINIMUM SPACING BETWEEN

LOUDSPEAKER CABLES, DIGITAL AV CABLES, AND ANALOG MICROPHONE CABLES.

F. ROUTE CABLING THROUGH UNDERFLOOR RACEWAY SYSTEM IN SPACES WHERE A RAISED ACCESS FLOOR IS

AVAILABLE.

G. ALL AV CABLING INSTALLED BELOW RAISED ACCESS FLOOR SHALL BE SUPPORTED ON J-HOOKS OR RINGS SPACED

AT 4' ON CENTERS MAXIMUM. DO NOT ALLOW CABLING TO CONTACT CONCRETE SLAB.

ELECTRICAL CONDUIT ROUGH-IN LEGEND:

FLAT PANEL DISPLAY MOUNTING SYSTEM WITH SPEAKERS (IF REQUIRED) SEE FLOOR PLANS FOR POWER AND

INTERFACE REQUIREMENTS. PROVIDE A POWER RECEPTACLE AT EACH DISPLAY LOCATION.

AUDIO VISUAL CEILING LOUDSPEAKER . AUDIO VISUAL CONTRACTOR TO PROVIDE MANUFACTURER'S BACK BOX AND MOUNTING ACCESSORIES FOR ALL LOCATIONS AS SHOWN ON PLANS. COORDINATE MOUNTING

LOCATION WITH MECHANICAL AND LIGHTING. INSTALLS IN CEILING GRID.

• ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL 3/4" CONDUIT BETWEEN LOUDSPEAKER BOXES IN HARD

CEILING SPACES AND/OR LOCATIONS THAT ARE INACCESSIBLE. ROUTE CONDUIT TO ACCESSIBLE CEILING

SPACES VIA PASS-THRU SLEEVES.

20 VOLT DUPLEX RECEPTACLE NEMA 5-20R. PROVIDED BY ELECTRICAL CONTRACTOR. SEE PLANS AND DETAILS

FOR LOCATIONS. ELEVATION IS AT 18" AFF OR AS NOTED ON PLANS.

DATA OUTLET. BACK BOX PROVIDED BY ELECTRICAL CONTRACTOR. SEE PLANS AND DETAILS FOR LOCATIONS AND QUANTITIES. ELEVATION IS AT 18" AFF OR AS NOTED ON PLANS. REFERENCE TELECOM DRAWINGS FOR

ROUGH-IN REQUIREMENTS.

• #SUBSCRIPT DETAILS NUMBER OF DATA DROPS PER LOCATION.

TELEVISION OUTLET WITH ONE DATA OUTLET, ONE VIDEO OVER IP OUTLET, AND CATV OUTLET. BACK BOX PROVIDED BY ELECTRICAL CONTRACTOR. SEE PLANS AND DETAILS FOR LOCATIONS AND QUANTITIES.

ELEVATION IS AT 18" AFF OR AS NOTED ON PLANS. REFERENCE TELECOM DRAWINGS FOR ROUGH-IN

REQUIREMENTS.

CATV OUTLET WITH ONE DATA OUTLET. BACK BOX PROVIDED BY ELECTRICAL CONTRACTOR. SEE PLANS AND DETAILS FOR LOCATIONS AND QUANTITIES. ELEVATION IS AT 18" AFF OR AS NOTED ON PLANS. REFERENCE

TELECOM DRAWINGS FOR ROUGH-IN REQUIREMENTS.

WALL MOUNTED CONTROL PANEL. REFERENCE FLOOR PLANS FOR LOCATION.

• ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL TWO-GANG BACK BOX MOUNTED AT 42-INCHES AFF

WITH CONDUITS AS SHOWN ON PLANS.

WALL MOUNTED INTERFACE CONNECTION PLATE. REFERENCE FLOOR PLANS FOR LOCATION.

• INP1 - UTILIZE EXISITING BACK BOX. SEE EACH SEET GENERAL NOTE.

• INP2 - UTILIZE EXISITING BACK BOX. SEE EACH SEET GENERAL NOTE.

• INP3 - UTILIZE EXISITING BACK BOX. SEE EACH SEET GENERAL NOTE.

• INP4 - UTILIZE EXISITING BACK BOX. SEE EACH SEET GENERAL NOTE.

SHEET LEGEND:

ABBREVIATION LEGEND:

A. LAN - LOCAL AREA NETWORK

B. NET - FACILITY COMPUTER NETWORK

C. RJ45 - EIGHT POSITION MODULAR PLUG AND JACK UTILIZED FOR TWISTED-PAIR CABLE CONNECTIONS

D. SC - FIBER OPTIC CABLE CONNECTOR FORM FACTOR

E. VOIP - VOICE OVER INTERNET PROTOCOL (IP) TELEPHONE SYSTEM

F. POE - POWER OVER ETHERNET

G. HDMI - HIGH-DEFINITION MULTIMEDIA INTERFACE DIGITAL VIDEO STANDARD

H. AEC - ACOUSTIC ECHO CANCELING MICROPHONE INPUT

I. PGM - PROGRAM AUDIO OR VIDEO

J. RS232 - UNBALANCED SERIAL CONTROL INTERFACE STANDARD

K. CNTR - CONTROL INPUT OR OUTPUT

L. OFE - OWNER FURNISHED EQUIPMENT

DEVICE LEGEND:

FLAT PANEL DISPLAY MOUNTING SYSTEM WITH INTEGRAL LOUDSPEAKER (IF REQUIRED, SEE FLOOR PLANS). SEE MOUNTED HEIGHTS AT XX"AFF TO CENTER OF SCREEN - SIZE DISPLAY AS INDICATED ON FLOOR PLANS.

COORDINATE EXACT LOCATION AS INDICATED ON FLOOR PLANS. COORDINATE MOUNTING WITH

ARCHITECTURAL AND FURNITURE LOCATIONS. SEE FLOOR PLANS FOR POWER, WALL BLOCKING, AND

INTERFACE REQUIREMENTS.

TYPE "S1" RECESSED CEILING LOUDSPEAKER PROVIDED AND INSTALLED BY AUDIO VISUAL CONTRACTOR.

SPEAKER TO BE WHITE IN COLOR, CONFIRM WITH ARCHITECT.

TYPE "S2" RECESSED HIGH-CEILING LOUDSPEAKER PROVIDED AND INSTALLED BY AUDIO VISUAL CONTRACTOR.

SPEAKER TO BE WHITE IN COLOR, CONFIRM WITH ARCHITECT.

TYPE "S3" PENDANT HIGH-LOUDSPEAKER PROVIDED AND INSTALLED BY AUDIO VISUAL CONTRACTOR. SPEAKER

TO BE WHITE IN COLOR, CONFIRM WITH ARCHITECT.

TYPE "S4" WALL MOUNTED LOUDSPEAKER PROVIDED AND INSTALLED BY AUDIO VISUAL CONTRACTOR.

SPEAKER TO BE WHITE IN COLOR, CONFIRM WITH ARCHITECT.

TYPE "S5" HORN LOADED PAGING LOUDSPEAKER PROVIDED AND INSTALLED BY AUDIO VISUAL CONTRACTOR.

SPEAKER TO BE WHITE IN COLOR, CONFIRM WITH ARCHITECT.

TYPE "S6" ABOVE FINISHED CEILING DUAL-WOOFER/HORN LOUDSPEAKER PROVIDED AND INSTALLED BY

AUDIO VISUAL CONTRACTOR. SPEAKER TO BE BLACK IN COLOR, CONFIRM WITH ARCHITECT.

TYPE "S7" WALL MOUNTED LOUDSPEAKER PROVIDED AND INSTALLED BY AUDIO VISUAL CONTRACTOR.

SPEAKER TO BE BLACK IN COLOR, CONFIRM WITH ARCHITECT.

WALL OR TABLE MOUNTED CONTROL PANEL. REFERENCE FLOOR PLANS FOR LOCATION.

• #SUBSCRIPT INDICATES MODEL TYPE. REFERENCE FLOOR PLAN & DETAILS FOR MODEL TYPE.

WALL MOUNTED INPUT INTERFACE CONNECTION PLATE. REFERENCE LARGE SCALE PLANS FOR LOCATION.

• #SUBSCRIPT INDICATES MODEL TYPE. REFERENCE DETAILS FOR ADDITIONAL INFORMATION.

WIRELESS MICROPHONE ANTENNA. REFERENCE FLOOR PLAN & CEILING PLANS FOR REQUIREMENTS.

INSTALL BELOW CEILING TILE USING TILE BRIDGE IN GRID OR SIMILAR MOUNTING DEVICE.

S1

AV

CTL#

AV

INP#

AV

ANT

S#

AV

CTL1

AV

INP#

TV

DS

D#

S2

S3

S4

S5

S6

S7

1 INTERNATIONAL DRIVE

L O

W E

R R

O

SW

E

LL

R O

A D

, S U

IT

E

O N

E M

A R

IE

T

T A

, G E

O R

G

IA

P

H O

N E

F

A X

W

W W

.J A

E N

G

IN

E E

R

IN

G .N

E T

Professional Seal

These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018

Project No:

Drawn By:

Checked By:

Original Document Size = 36" x 48"

C

U se rs \j p a rk \D o cu m e n ts

\1

_S a va n n a h

C o n ve n ti o n _C e n te r_

E xi st in g J&

A _C e n tr a l_ R

JP

A R

K

.r vt

/1

/2

:4

:1

A

M

AV0-000

COVER PAGE

JP

VP

18051

05/01/23AV BID SET

SI

T

C C

A U

D

IO

-V

IS

U A

L R

E N

O V

A T

IO

N

SA

V

A N

N A

H , G

E O

R G

IA

A U

D

IO

V

IS

U A

L S

Y

ST

E M

C

O V

E R

P A

G E

AV BID SET

AV0-000 COVER PAGE

AV2-100 OVERALL FLOOR PLAN - LEVEL 1

AV2-101 LEVEL 1 - FLOOR PLAN - ZONE 1

AV2-102 LEVEL 1 - FLOOR PLAN - ZONE 2

AV2-103 LEVEL 1 - FLOOR PLAN - ZONE 3

AV2-106 LEVEL 1 - FLOOR PLAN - ZONE 6

AV2-107 LEVEL 1 - FLOOR PLAN - ZONE 7

AV2-108 LEVEL 1 - FLOOR PLAN - ZONE 8

AV2-111 LEVEL 1 - FLOOR PLAN - ZONE 11

AV2-200 OVERALL FLOOR PLAN - LEVEL 2

AV2-202 LEVEL 2 - FLOOR PLAN - ZONE 2

AV2-206 LEVEL 2 - FLOOR PLAN - ZONE 6

AV2-207 LEVEL 2 - FLOOR PLAN - ZONE 7

AV2-211 LEVEL 2 - FLOOR PLAN - ZONE 11

AV3-100 LEVEL 1 - RCP - OVERALL

AV3-101 LEVEL 1 - RCP - ZONE 1

AV3-102 LEVEL 1 - RCP - ZONE 2

AV3-106 LEVEL 1 - RCP - ZONE 6

AV3-111 LEVEL 1 - RCP - ZONE 11

AV3-112 LEVEL 1 - RCP - ZONE 12

AV3-200 LEVEL 2 - RCP - OVERALL

AV3-201 LEVEL 2- RCP - ZONE 1

AV3-202 LEVEL 2 - RCP - ZONE 2

AV3-206 LEVEL 2 - RCP - ZONE 6

AV3-207 LEVEL 2 - RCP - ZONE 7

AV3-208 LEVEL 2 - RCP - ZONE 8

AV3-211 LEVEL 2 - RCP - ZONE 11

AV3-212 LEVEL 2 - RCP - ZONE 12

AV4-101 LARGE SCALES - BOARDROOMS

AV4-102 LARGE SCALES - MEETING ROOMS

AV4-103 LARGE SCALES - MEETING ROOMS, AV RACK ROOM

AV4-104 LARGE SCALES - OGLETHORPE AUDITORIUM

AV4-105 LARGE SCALES - BALLROOM

AV4-106 LARGE SCALES - MEETING ROOMS - LEVEL 2

AV5-101 ONE-LINE DIAGRAM - EXHIBIT TIE LINE

AV5-102 ONE-LINE DIAGRAM - MEETING ROOM TIE LINE

AV5-103 ONE-LINE DIAGRAM - MEETING ROOM TIE LINE

AV5-104 ONE-LINE DIAGRAM - BALLROOM TIE LINE

AV5-105 ONE-LINE DIAGRAM - BALLROOM

AV5-106 ONE-LINE DIAGRAM - EXHIBIT HALL AUDIO #1

AV5-107 ONE-LINE DIAGRAM - EXHIBIT HALL AUDIO #2

AV5-108 ONE-LINE DIAGRAM - EXHIBIT HALL AUDIO #3

AV5-109 ONE-LINE DIAGRAM - EXHIBIT HALL AUDIO #4

AV5-110 ONE-LINE DIAGRAM - CONTROL SYSTEM

AV5-111 ONE-LINE DIAGRAM - OGLETHORPE AUDITORIUM

AV5-112 ONE-LINE DIAGRAM - BOARDROOMS

AV5-113 ONE-LINE DIAGRAM - DS & RS

AV6-101 DETAILS

UP

RESTROOM-

WOMEN

10808

HALL A

C2.5

HALL B

#43

CONCOURSE

EAST LOBBY/

REGISTRATION

10309MECHANICAL

ROOM

B.O.H.

RESTAURANT

CAFE

439CONCOURSE

RECEPTION

STORAGE

CONCOURSE

B.O.H.

B.O.H.

C3.76

LOADING DOCK

209.

UNIFORM ISSUE

C3.386

PUBLIC STAIRS

PUBLIC STAIRS

LOADING DOCK

209.

LOADING DOCK

209.

B.O.H.

B.O.H.

AV4-103

STORAGE

B.O.H.

210.

B.O.H.

B.O.H.

HALL C

10804

TRUCK PARKING AV4-102

AV4-102

AV4-102

AV4-103

AV4-104

AV4-101

AV4-101

BOARDROOM-

GWINNETT

BOARDROOM-

GREENE

BOARDROOM-

PULASKI

BOARDROOM-

JASPER

MEETING ROOM

MEETING ROOM

MEETING ROOM

MEETING ROOM

MEETING ROOM

MEETING ROOM

MEETING ROOM

OGLETHORPE

AUDITORIUM

NEW CONSTRUCTION

CONCESSIONS

RIVER CONCOURCE

ROTUNDA

REGISTRATION

RECEPTION

AV4-103

MAIN EQUIPMENT RACK ROOM

AV EQUIPMENT RACK ROOM

DEDICATED FIBER OPTIC FOR DIGITAL AUDIO

NETWORK & CONTROL

6-STRAND SM BY AUDIO VISUAL CONTRACTOR

( REFER TO

TELECOM DRAWINGS FOR CONDUIT PATHWAY)

TO IDF/AV 10812

TO IDF/AV 10333

DEDICATED FIBER OPTIC FOR DIGITAL AUDIO

NETWORK & CONTROL

6-STRAND SM BY AUDIO VISUAL CONTRACTOR

( REFER TO

TELECOM DRAWINGS FOR CONDUIT

PATHWAY) DEDICATED FIBER OPTIC FOR DIGITAL

AUDIO NETWORK & CONTROL

6-STRAND SM BY AUDIO VISUAL

CONTRACTOR ( REFER TO

TELECOM DRAWINGS FOR CONDUIT

PATHWAY)

B.O.H.

N

ZONE 08ZONE 13 ZONE 03

ZONE 07ZONE 12 ZONE 02

ZONE 06ZONE 11 ZONE 01

ZONE 09ZONE 14 ZONE 04

ZONE 10ZONE 15 ZONE 05

A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR

LEVEL 1

LEVEL 2 & P1

LEVEL 3 & P2

LEVEL 4 & P3

LEVEL 5 & P4

LEVEL 6 & P5

LEVEL 7

DIAGRAM SECTION CUT

AT ZONES 13, 08, 03

L O

W E

R R

O

SW

E

LL

R O

A D

, S U

IT

E

O N

E M

A R

IE

T

T A

, G E

O R

G

IA

P

H O

N E

F

A X

W

W W

.J A

E N

G

IN

E E

R

IN

G .N

E T

Professional Seal

These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018

Project No:

Drawn By:

Checked By:

Original Document Size = 36" x 48"

C

U se rs \j p a rk \D o cu m e n ts

\1

_S a va n n a h

C o n ve n ti o n _C e n te r_

E xi st in g J&

A _C e n tr a l_ R

JP

A R

K

.r vt

/1

/2

:4

:2

A

M

AV2-100

OVERALL FLOOR PLAN - LEVEL

JP

VP

18051

05/01/23AV BID SET

SI

T

C C

A U

D

IO

-V

IS

U A

L R

E N

O V

A T

IO

N

SA

V

A N

N A

H , G

E O

R G

IA

A U

D

IO

V

IS

U A

L S

Y

ST

E M

F

L O

O R

P L A

N

AV BID SET

FLOOR PLAN

1" = 20'-0" 1

OVERALL FLOOR PLAN - LEVEL 1

S4S4

S4S4 S4S4 S4S4

S4S4

S4S4

S4S4

S4S4

S4S4

MEETING ROOMS

32"D

32"D

TYP.

7 AV

INP1

TO MAIN

EQUIPMENT

RACK ROOM

TYP.

TO MAIN

EQUIPMENT

RACK ROOM

TO MAIN

EQUIPMENT

RACK ROOM

EXISTING

VIDEO WALL

TO REMAIN

226"D

Z1-1.1 Z1-1.1 Z1-1.1

Z1-1.1

Z1-1.1

Z2-1.1

Z1-1.1

Z1-1.1

B.O.H.

N

ZONE 08ZONE 13 ZONE 03

ZONE 07ZONE 12 ZONE 02

ZONE 06ZONE 11 ZONE 01

ZONE 09ZONE 14 ZONE 04

ZONE 10ZONE 15 ZONE 05

A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR

LEVEL 1

LEVEL 2 & P1

LEVEL 3 & P2

LEVEL 4 & P3

LEVEL 5 & P4

LEVEL 6 & P5

LEVEL 7

DIAGRAM SECTION CUT

AT ZONES 13, 08, 03

L O

W E

R R

O

SW

E

LL

R O

A D

, S U

IT

E

O N

E M

A R

IE

T

T A

, G E

O R

G

IA

P

H O

N E

F

A X

W

W W

.J A

E N

G

IN

E E

R

IN

G .N

E T

Professional Seal

These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018

Project No:

Drawn By:

Checked By:

Original Document Size = 36" x 48"

C

U se rs \j p a rk \D o cu m e n ts

\1

_S a va n n a h

C o n ve n ti o n _C e n te r_

E xi st in g J&

A _C e n tr a l_ R

JP

A R

K

.r vt

/1

/2

:4

:2

A

M

AV2-101

LEVEL 1 - FLOOR PLAN - ZONE

JP

LC/JD

18051

05/01/23AV BID SET

SI

T

C C

A U

D

IO

-V

IS

U A

L R

E N

O V

A T

IO

N

SA

V

A N

N A

H , G

E O

R G

IA

A U

D

IO

V

IS

U A

L S

Y

ST

E M

F

L O

O R

P L A

N

AV BID SET

32-INCH ROOM SCHEDULING DISPLAY.

ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL A PASS &

SEYMOUR TV2M, BY LEGRAND, FOR AV BACKBOX. ALSO PROVIDE

AND INSTALL ONE (1) 120V/1-PHASE DUPLEX RECEPTACLE IN

SPACE PROVIDED BEHIND FLAT PANEL DISPLAY, ADJACENT

BRACKET LOCATION.

TELECOM CONTRACTOR TO PROVIDE AND INSTALL DATA

OUTLET(S) IN SPACE PROVIDED..

AUDIO VSUAL CONTRACTOR TO PROVIDE AND INSTALL WALL

MOUNTED LOUDSPEAKERS.

ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ONE 1-

GANG BACK BOX FLUSH-MOUNTED IN WALL AT 120-INCHES A.F.F

TO CENTER AND ONE (1) 1-INCH CONDUIT , STUBBED UP TO

ACCESSIBLE CEILING FOR WALL LOUDSPEAKER.

CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT

CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE

INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE

PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND

INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-

ACCESSIBLE CEILING OR HARD CEILING AREAS.

AUDIO VISUAL CONTRACTOR TO REMOVE EXISTING WALL

INTERFACE PLATE WITH CABLES AND INSTALL NEW FINISHED

CONNECTORIZED PLATE IN SAME LOCATION. REFERENCE PLATE

DETAILS. AUDIO VISUAL CONTRATOR TO UTILIZE EXISTING A 4-

GANG BACK BOX FOR PATHWAY ROUTE TO RACK ROOM.

KEY NOTES:

FLOOR PLAN

1/8" = 1'-0" 1

FLOOR PLAN - LEVEL 1 - ZONE 1

A. UTILIZE EXISTING CONDUIT OR PATHWAY AND RUN THROUGH

AV RACK ACCESS.

B. UTILIZE EXISTING POWER RECEPTACLE. AUDIO VISUAL

CONTRACTOR TO DETERMINE IF CIRCUIT IS DEDICATED AND IF

SECOND CIRCUIT IS REQUIRED.

GENERAL NOTES:

S4S4 S4S4

S4S4

S4S4 S4S4

S4S4

MEETING ROOMS

106.

101.

100.

1 2

TYP.

TO MAIN

EQUIPMENT

RACK ROOM

(1)1"C

65"D

DS

CONCESSIONS

AV

INP1

AV

INP1

AV

INP1

TO MAIN

EQUIPMENT

RACK ROOM

Z2-1.1

TYP.

TYP.

TYP.

Z2-1.1

Z2-1.1

Z2-1.1

Z2-1.1

Z2-1.1

Z2-1.1

Z2-1.1

B.O.H.

B.O.H.

N

ZONE 08ZONE 13 ZONE 03

ZONE 07ZONE 12 ZONE 02

ZONE 06ZONE 11 ZONE 01

ZONE 09ZONE 14 ZONE 04

ZONE 10ZONE 15 ZONE 05

A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR

LEVEL 1

LEVEL 2 & P1

LEVEL 3 & P2

LEVEL 4 & P3

LEVEL 5 & P4

LEVEL 6 & P5

LEVEL 7

DIAGRAM SECTION CUT

AT ZONES 13, 08, 03

L O

W E

R R

O

SW

E

LL

R O

A D

, S U

IT

E

O N

E M

A R

IE

T

T A

, G E

O R

G

IA

P

H O

N E

F

A X

W

W W

.J A

E N

G

IN

E E

R

IN

G .N

E T

Professional Seal

These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018

Project No:

Drawn By:

Checked By:

Original Document Size = 36" x 48"

C

U se rs \j p a rk \D o cu m e n ts

\1

_S a va n n a h

C o n ve n ti o n _C e n te r_

E xi st in g J&

A _C e n tr a l_ R

JP

A R

K

.r vt

/1

/2

:4

:2

A

M

AV2-102

LEVEL 1 - FLOOR PLAN - ZONE

JP

LC/JD

18051

05/01/23AV BID SET

SI

T

C C

A U

D

IO

-V

IS

U A

L R

E N

O V

A T

IO

N

SA

V

A N

N A

H , G

E O

R G

IA

A U

D

IO

V

IS

U A

L S

Y

ST

E M

F

L O

O R

P L A

N

AV BID SET

FLOOR PLAN

1/8" = 1'-0" 1

FLOOR PLAN - LEVEL 1 - ZONE 2

AUDIO VSUAL CONTRACTOR TO PROVIDE AND INSTALL WALL

MOUNTED LOUDSPEAKERS.

ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ONE 1-

GANG BACK BOX FLUSH-MOUNTED IN WALL AT 120-INCHES A.F.F

TO CENTER AND ONE (1) 1-INCH CONDUIT , STUBBED UP TO

ACCESSIBLE CEILING FOR WALL LOUDSPEAKER.

CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT

CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE

INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE

PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND

INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-

ACCESSIBLE CEILING OR HARD CEILING AREAS.

AUDIO VISUAL CONTRACTOR TO REMOVE EXISTING WALL

INTERFACE PLATE WITH CABLES AND INSTALL NEW FINISHED

CONNECTORIZED PLATE IN SAME LOCATION. REFERENCE PLATE

DETAILS. AUDIO VISUAL CONTRATOR TO UTILIZE EXISTING A 4-

GANG BACK BOX FOR PATHWAY ROUTE TO RACK ROOM.

65-INCH SIGNAGE DISPLAY. ELECTRICAL CONTRACTOR TO

PROVIDE AND INSTALL A PASS & SEYMOUR TV2M, BY LEGRAND,

FOR AV BACKBOX. ALSO PROVIDE AND INSTALL ONE (1) 120V/1-

PHASE DUPLEX RECEPTACLE IN SPACE PROVIDED BEHIND

FLAT PANEL DISPLAY AT 78" AFF. TELECOM CONTRACTOR TO

PROVIDE AND INSTALL DATA OUTLET(S) IN SPACE PROVIDED.

KEY NOTES:

A. UTILIZE EXISTING CONDUIT OR PATHWAY AND RUN THROUGH

AV RACK ACCESS.

B. UTILIZE EXISTING POWER RECEPTACLE. AUDIO VISUAL

CONTRACTOR TO DETERMINE IF CIRCUIT IS DEDICATED AND IF

SECOND CIRCUIT IS REQUIRED.

100.

EAST LOBBY/

REGISTRATION

10308

HALL C

10804

HALL B

#43

AV

EX

STAIR #22

10301

Z2-1.1

1 2 3

N

ZONE 08ZONE 13 ZONE 03

ZONE 07ZONE 12 ZONE 02

ZONE 06ZONE 11 ZONE 01

ZONE 09ZONE 14 ZONE 04

ZONE 10ZONE 15 ZONE 05

A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR

LEVEL 1

LEVEL 2 & P1

LEVEL 3 & P2

LEVEL 4 & P3

LEVEL 5 & P4

LEVEL 6 & P5

LEVEL 7

DIAGRAM SECTION CUT

AT ZONES 13, 08, 03

L O

W E

R R

O

SW

E

LL

R O

A D

, S U

IT

E

O N

E M

A R

IE

T

T A

, G E

O R

G

IA

P

H O

N E

F

A X

W

W W

.J A

E N

G

IN

E E

R

IN

G .N

E T

Professional Seal

These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018

Project No:

Drawn By:

Checked By:

Original Document Size = 36" x 48"

C

U se rs \j p a rk \D o cu m e n ts

\1

_S a va n n a h

C o n ve n ti o n _C e n te r_

E xi st in g J&

A _C e n tr a l_ R

JP

A R

K

.r vt

/1

/2

:4

:3

A

M

AV2-103

LEVEL 1 - FLOOR PLAN - ZONE

JP

LC/JD

18051

05/01/23AV BID SET

SI

T

C C

A U

D

IO

-V

IS

U A

L R

E N

O V

A T

IO

N

SA

V

A N

N A

H , G

E O

R G

IA

A U

D

IO

V

IS

U A

L S

Y

ST

E M

F

L O

O R

P L A

N

AV BID SET

FLOOR PLAN

1/8" = 1'-0" 1

FLOOR PLAN - LEVEL 1 - ZONE 3

A. UTILIZE EXISTING CONDUIT OR PATHWAY AND RUN THROUGH

AV RACK ACCESS.

B. UTILIZE EXISTING POWER RECEPTACLE. AUDIO VISUAL

CONTRACTOR TO DETERMINE IF CIRCUIT IS DEDICATED AND IF

SECOND CIRCUIT IS REQUIRED.

GENERAL NOTES:

AUDIO VSUAL CONTRACTOR TO PROVIDE AND INSTALL WALL

MOUNTED LOUDSPEAKERS.

ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ONE 1-

GANG BACK BOX FLUSH-MOUNTED IN WALL AT 120-INCHES A.F.F

TO CENTER AND ONE (1) 1-INCH CONDUIT , STUBBED UP TO

ACCESSIBLE CEILING FOR WALL LOUDSPEAKER.

CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT

CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE

INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE

PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND

INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-

ACCESSIBLE CEILING OR HARD CEILING AREAS.

EXISTING AV WALL INTERFACE PLATE. AUDIO VISUAL

CONTRACTOR TO LEAVE IN EXISTING WALL INTERFACE PLATE.

KEY NOTES:

S4S4S4S4 S4S4

S4S4

S4S4

S4S4 S4S4 S4S4 S4S4 S4S4 S4S4

S4S4 S4S4 S4S4 S4S4 S4S4

S4S4

S4S4

S4S4

STORAGE

B.O.H.

B.O.H.

RIVER CONCOURSE

4 AV

INP2

AV

INP2

TO MAIN

EQUIPMENT

RACK ROOM

Z1-1.1

Z6-1.1 Z6-1.1 Z6-1.1 Z6-1.1

Z6-1.1

Z6-1.1

Z6-1.1

Z6-1.1

Z6-1.1 Z6-1.1 Z6-1.1 Z6-1.1 Z6-1.1 Z6-1.1

Z6-1.2Z6-1.2Z6-1.2 Z6-1.2

Z6-1.2

2 4TYP.

TYP.

TYP.

TYP.

Z11-1.1

N

ZONE 08ZONE 13 ZONE 03

ZONE 07ZONE 12 ZONE 02

ZONE 06ZONE 11 ZONE 01

ZONE 09ZONE 14 ZONE 04

ZONE 10ZONE 15 ZONE 05

A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR

LEVEL 1

LEVEL 2 & P1

LEVEL 3 & P2

LEVEL 4 & P3

LEVEL 5 & P4

LEVEL 6 & P5

LEVEL 7

DIAGRAM SECTION CUT

AT ZONES 13, 08, 03

L O

W E

R R

O

SW

E

LL

R O

A D

, S U

IT

E

O N

E M

A R

IE

T

T A

, G E

O R

G

IA

P

H O

N E

F

A X

W

W W

.J A

E N

G

IN

E E

R

IN

G .N

E T

Professional Seal

These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018

Project No:

Drawn By:

Checked By:

Original Document Size = 36" x 48"

C

U se rs \j p a rk \D o cu m e n ts

\1

_S a va n n a h

C o n ve n ti o n _C e n te r_

E xi st in g J&

A _C e n tr a l_ R

JP

A R

K

.r vt

/1

/2

:4

:3

A

M

AV2-106

LEVEL 1 - FLOOR PLAN - ZONE

JP

LC/JD

18051

05/01/23AV BID SET

SI

T

C C

A U

D

IO

-V

IS

U A

L R

E N

O V

A T

IO

N

SA

V

A N

N A

H , G

E O

R G

IA

A U

D

IO

V

IS

U A

L S

Y

ST

E M

F

L O

O R

P L A

N

AV BID SET

FLOOR PLAN

1/8" = 1'-0" 1

FLOOR PLAN - LEVEL 1 - ZONE 6

A. UTILIZE EXISTING CONDUIT OR PATHWAY AND RUN THROUGH

AV RACK ACCESS.

B. UTILIZE EXISTING POWER RECEPTACLE. AUDIO VISUAL

CONTRACTOR TO DETERMINE IF CIRCUIT IS DEDICATED AND IF

SECOND CIRCUIT IS REQUIRED.

GENERAL NOTES:

AUDIO VSUAL CONTRACTOR TO PROVIDE AND INSTALL WALL

MOUNTED LOUDSPEAKERS.

ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ONE 1-

GANG BACK BOX FLUSH-MOUNTED IN WALL AT 120-INCHES A.F.F

TO CENTER AND ONE (1) 1-INCH CONDUIT , STUBBED UP TO

ACCESSIBLE CEILING FOR WALL LOUDSPEAKER.

CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT

CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE

INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE

PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND

INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-

ACCESSIBLE CEILING OR HARD CEILING AREAS.

AUDIO VISUAL CONTRACTOR TO REMOVE EXISTING WALL

INTERFACE PLATE WITH CABLES AND INSTALL NEW FINISHED

CONNECTORIZED PLATE IN SAME LOCATION. REFERENCE PLATE

DETAILS. AUDIO VISUAL CONTRATOR TO UTILIZE EXISTING A 4-

GANG BACK BOX FOR PATHWAY ROUTE TO RACK ROOM.

KEY NOTES:

S

S

S

S

HALL A

C2.5

HALL B

#43

B.O.H.

C3.76

LOADING DOCK

209.

LOADING DOCK

209.

B.O.H.

AV

INP1

AV

INP1

AV

INP1

AV

INP1

AV

INP1

AV

INP1

AV

INP1

AV

INP1

TO MAIN

EQUIPMENT

RACK ROOM

TYP.

TYP.

TYP.

FOR DANTE AUDIO & AUDIO NETWORK CABLING DISTANCE

BEYOND 90 METERS IN TOTAL CABLE LENGTH, CONTRACTOR TO

PROVIDE AND INSTALL POE EXTENDERS.

N

ZONE 08ZONE 13 ZONE 03

ZONE 07ZONE 12 ZONE 02

ZONE 06ZONE 11 ZONE 01

ZONE 09ZONE 14 ZONE 04

ZONE 10ZONE 15 ZONE 05

A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR

LEVEL 1

LEVEL 2 & P1

LEVEL 3 & P2

LEVEL 4 & P3

LEVEL 5 & P4

LEVEL 6 & P5

LEVEL 7

DIAGRAM SECTION CUT

AT ZONES 13, 08, 03

L O

W E

R R

O

SW

E

LL

R O

A D

, S U

IT

E

O N

E M

A R

IE

T

T A

, G E

O R

G

IA

P

H O

N E

F

A X

W

W W

.J A

E N

G

IN

E E

R

IN

G .N

E T

Professional Seal

These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018

Project No:

Drawn By:

Checked By:

Original Document Size = 36" x 48"

C

U se rs \j p a rk \D o cu m e n ts

\1

_S a va n n a h

C o n ve n ti o n _C e n te r_

E xi st in g J&

A _C e n tr a l_ R

JP

A R

K

.r vt

/1

/2

:4

:3

A

M

AV2-107

LEVEL 1 - FLOOR PLAN - ZONE

JP

LC/JD

18051

05/01/23AV BID SET

SI

T

C C

A U

D

IO

-V

IS

U A

L R

E N

O V

A T

IO

N

SA

V

A N

N A

H , G

E O

R G

IA

A U

D

IO

V

IS

U A

L S

Y

ST

E M

F

L O

O R

P L A

N

AV BID SET

FLOOR PLAN

1/8" = 1'-0" 1

FLOOR PLAN - LEVEL 1 - ZONE 7

AUDIO VISUAL CONTRACTOR TO REMOVE EXISTING WALL

INTERFACE PLATE WITH CABLES AND INSTALL NEW FINISHED

CONNECTORIZED PLATE IN SAME LOCATION. REFERENCE PLATE

DETAILS. AUDIO VISUAL CONTRATOR TO UTILIZE EXISTING A 4-

GANG BACK BOX FOR PATHWAY ROUTE TO RACK ROOM.

WALL MOUNTED LOUDSPEAKER "S5". ELECTRICAL CONTRACTOR

TO PROVIDE AND INSTALL ONE (1) - 1-GANG WALL BOX LOCATED

AT 96-INCHES AFF. SUB-UP ONE(1) 1-INCH CONDUIT TO

ACCESSIBLE CIEILING. SEE DETAIL DRAWINGS FOR ADDITIONAL

INFORMATION.

CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT

CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE

INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE

PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND

INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-

ACCESSIBLE CEILING OR HARD CEILING AREAS.

KEY NOTES:

A. UTILIZE EXISTING CONDUIT OR PATHWAY AND RUN THROUGH

AV RACK ACCESS.

B. UTILIZE EXISTING POWER RECEPTACLE. AUDIO VISUAL

CONTRACTOR TO DETERMINE IF CIRCUIT IS DEDICATED AND IF

SECOND CIRCUIT IS REQUIRED.

GENERAL NOTES:

S5

S

S

S

RESTROOM-

WOMEN

10808

LOADING DOCK

209.

LOADING DOCK

209.

HALL B

#43

HALL C

10804

LOADING DOCK

10806

BACK OF HOUSE

CORRIDOR

11AV

INP1

AV

INP1

TO MAIN

EQUIPMENT

RACK ROOM

TYP.

TYP.

Z12-1.1

Z12-1.1

Z12-1.1

Z12-1.1

TO IDF/AV

10812

(1)1-1/2"

TO IDF/AV

10333

(1)1-1/2"

N

ZONE 08ZONE 13 ZONE 03

ZONE 07ZONE 12 ZONE 02

ZONE 06ZONE 11 ZONE 01

ZONE 09ZONE 14 ZONE 04

ZONE 10ZONE 15 ZONE 05

A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR

LEVEL 1

LEVEL 2 & P1

LEVEL 3 & P2

LEVEL 4 & P3

LEVEL 5 & P4

LEVEL 6 & P5

LEVEL 7

DIAGRAM SECTION CUT

AT ZONES 13, 08, 03

L O

W E

R R

O

SW

E

LL

R O

A D

, S U

IT

E

O N

E M

A R

IE

T

T A

, G E

O R

G

IA

P

H O

N E

F

A X

W

W W

.J A

E N

G

IN

E E

R

IN

G .N

E T

Professional Seal

These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018

Project No:

Drawn By:

Checked By:

Original Document Size = 36" x 48"

C

U se rs \j p a rk \D o cu m e n ts

\1

_S a va n n a h

C o n ve n ti o n _C e n te r_

E xi st in g J&

A _C e n tr a l_ R

JP

A R

K

.r vt

/1

/2

:4

:3

A

M

AV2-108

LEVEL 1 - FLOOR PLAN - ZONE

JP

LC/JD

18051

05/01/23AV BID SET

SI

T

C C

A U

D

IO

-V

IS

U A

L R

E N

O V

A T

IO

N

SA

V

A N

N A

H , G

E O

R G

IA

A U

D

IO

V

IS

U A

L S

Y

ST

E M

F

L O

O R

P L A

N

AV BID SET

FLOOR PLAN

1/8" = 1'-0" 1

FLOOR PLAN - LEVEL 1 - ZONE 8

AUDIO VISUAL CONTRACTOR TO REMOVE EXISTING WALL

INTERFACE PLATE WITH CABLES AND INSTALL NEW FINISHED

CONNECTORIZED PLATE IN SAME LOCATION. REFERENCE PLATE

DETAILS. AUDIO VISUAL CONTRATOR TO UTILIZE EXISTING A 4-

GANG BACK BOX FOR PATHWAY ROUTE TO RACK ROOM.

WALL MOUNTED LOUDSPEAKER "S5". ELECTRICAL CONTRACTOR

TO PROVIDE AND INSTALL ONE (1) - 1-GANG WALL BOX LOCATED

AT 96-INCHES AFF. SUB-UP ONE(1) 1-INCH CONDUIT TO

ACCESSIBLE CIEILING. SEE DETAIL DRAWINGS FOR ADDITIONAL

INFORMATION.

CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT

CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE

INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE

PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND

INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-

ACCESSIBLE CEILING OR HARD CEILING AREAS.

KEY NOTES:

A. UTILIZE EXISTING CONDUIT OR PATHWAY AND RUN THROUGH

AV RACK ACCESS.

B. UTILIZE EXISTING POWER RECEPTACLE. AUDIO VISUAL

CONTRACTOR TO DETERMINE IF CIRCUIT IS DEDICATED AND IF

SECOND CIRCUIT IS REQUIRED.

GENERAL NOTES:

S4S4S4S4 S4S4

S4S4

S4S4

S4S4

S4S4

S4S4 S4S4

RESTAURANT

CAFE

MEETING ROOMS

C3.388

MEETING ROOMS

C3.389

MEETING ROOMS

C3.390

MEETING ROOMS

Administrative

Offices

RECEPTION

B.O.H.

B.O.H.

1 2

(TYP)

AV

CTL1

AV

INP2

AV

INP2

(TYP)

Z11-1.1 Z11-1.1 Z11-1.1 Z11-1.1 Z11-1.1

Z11-1.1 Z11-1.1

Z11-1.1Z11-1.1

Z11-1.1

TO AV

RACK

N

ZONE 08ZONE 13 ZONE 03

ZONE 07ZONE 12 ZONE 02

ZONE 06ZONE 11 ZONE 01

ZONE 09ZONE 14 ZONE 04

ZONE 10ZONE 15 ZONE 05

A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR

LEVEL 1

LEVEL 2 & P1

LEVEL 3 & P2

LEVEL 4 & P3

LEVEL 5 & P4

LEVEL 6 & P5

LEVEL 7

DIAGRAM SECTION CUT

AT ZONES 13, 08, 03

L O

W E

R R

O

SW

E

LL

R O

A D

, S U

IT

E

O N

E M

A R

IE

T

T A

, G E

O R

G

IA

P

H O

N E

F

A X

W

W W

.J A

E N

G

IN

E E

R

IN

G .N

E T

Professional Seal

These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018

Project No:

Drawn By:

Checked By:

Original Document Size = 36" x 48"

C

U se rs \j p a rk \D o cu m e n ts

\1

_S a va n n a h

C o n ve n ti o n _C e n te r_

E xi st in g J&

A _C e n tr a l_ R

JP

A R

K

.r vt

/1

/2

:4

:4

A

M

AV2-111

LEVEL 1 - FLOOR PLAN - ZONE

JP

LC/JD

18051

05/01/23AV BID SET

SI

T

C C

A U

D

IO

-V

IS

U A

L R

E N

O V

A T

IO

N

SA

V

A N

N A

H , G

E O

R G

IA

A U

D

IO

V

IS

U A

L S

Y

ST

E M

F

L O

O R

P L A

N

AV BID SET

FLOOR PLAN

1/8" = 1'-0" 1

FLOOR PLAN - LEVEL 1 - ZONE 11

AUDIO VSUAL CONTRACTOR TO PROVIDE AND INSTALL WALL

MOUNTED LOUDSPEAKERS.

ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ONE 1-

GANG BACK BOX FLUSH-MOUNTED IN WALL AT 120-INCHES A.F.F

TO CENTER AND ONE (1) 1-INCH CONDUIT , STUBBED UP TO

ACCESSIBLE CEILING FOR WALL LOUDSPEAKER.

CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT

CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE

INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE

PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND

INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-

ACCESSIBLE CEILING OR HARD CEILING AREAS.

AUDIO VISUAL CONTRACTOR TO REMOVE EXISTING WALL

INTERFACE PLATE WITH CABLES AND INSTALL NEW FINISHED

CONNECTORIZED PLATE IN SAME LOCATION. REFERENCE PLATE

DETAILS. AUDIO VISUAL CONTRATOR TO UTILIZE EXISTING A 4-

GANG BACK BOX FOR PATHWAY ROUTE TO RACK ROOM.

KEY NOTES:

A. UTILIZE EXISTING CONDUIT OR PATHWAY AND RUN THROUGH

AV RACK ACCESS.

B. UTILIZE EXISTING POWER RECEPTACLE. AUDIO VISUAL

CONTRACTOR TO DETERMINE IF CIRCUIT IS DEDICATED AND IF

DN

DN

PUBLIC STAIRS

#34

21301

BEER & WINE

20809

SECURED

LIQUOR

STORAGE

20808

PUBLIC STAIRS

20302

AV4-105

AV4-106

AV4-106

GEORGIA

INTERNATIONAL

GALLERY

GEORGIA

INTERNATIONAL

GALLERY

BALLROOM

BALLROOM

BALLROOM

B.O.H.

MAIN KITCHEN

KITCHEN / BOH

KITCHEN / BOH

EAST

CONCOURSE

20308

GEORGIA

INTERNATIONAL

GALLERY

B.O.H.

OGLETHORPE

AUDITORIUM

OGLETHORPE

AUDITORIUM

MEETING ROOM

MEETING ROOM

MEETING ROOM

MEETING ROOM

MEETING ROOM

MEETING ROOM

NEW CONSTRUCTION

OPEN TO

BELOW

RIVER CONCOURSE PUBLIC CORRIDOE

RIVER CONCOURSE SERVICE CORRIDOE

O P

E N

T O

B E

L O

W N

ZONE 08ZONE 13 ZONE 03

ZONE 07ZONE 12 ZONE 02

ZONE 06ZONE 11 ZONE 01

ZONE 09ZONE 14 ZONE 04

ZONE 10ZONE 15 ZONE 05

A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR

LEVEL 1

LEVEL 2 & P1

LEVEL 3 & P2

LEVEL 4 & P3

LEVEL 5 & P4

LEVEL 6 & P5

LEVEL 7

DIAGRAM SECTION CUT

AT ZONES 13, 08, 03

L O

W E

R R

O

SW

E

LL

R O

A D

, S U

IT

E

O N

E M

A R

IE

T

T A

, G E

O R

G

IA

P

H O

N E

F

A X

W

W W

.J A

E N

G

IN

E E

R

IN

G .N

E T

Professional Seal

These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018

Project No:

Drawn By:

Checked By:

Original Document Size = 36" x 48"

C

U se rs \j p a rk \D o cu m e n ts

\1

_S a va n n a h

C o n ve n ti o n _C e n te r_

E xi st in g J&

A _C e n tr a l_ R

JP

A R

K

.r vt

/1

/2

:4

:0

A

M

AV2-200

OVERALL FLOOR PLAN - LEVEL

JP

LC/JD

18051

05/01/23AV BID SET

SI

T

C C

A U

D

IO

-V

IS

U A

L R

E N

O V

A T

IO

N

SA

V

A N

N A

H , G

E O

R G

IA

A U

D

IO

V

IS

U A

L S

Y

ST

E M

F

L O

O R

P L A

N

AV BID SET

FLOOR PLAN

OVERALL FLOOR PLAN - LEVEL 2

S4S4 S4S4

S4S4

S4S4

S4S4

GEORGIA

INTERNATIONAL

GALLERY

GEORGIA

INTERNATIONAL

GALLERY

RS

RS

RS

RS

1 2

(TYP)

TO MAIN

EQUIPMENT

RACK ROOM

(TYP)

TO MAIN

EQUIPMENT

RACK ROOM

(TYP)

Z2-2.2

Z2-2.2

Z2-2.2

Z2-2.2 Z2-2.2

REFERENCE AV4-106

REFERENCE AV4-106

N

ZONE 08ZONE 13 ZONE 03

ZONE 07ZONE 12 ZONE 02

ZONE 06ZONE 11 ZONE 01

ZONE 09ZONE 14 ZONE 04

ZONE 10ZONE 15 ZONE 05

A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR

LEVEL 1

LEVEL 2 & P1

LEVEL 3 & P2

LEVEL 4 & P3

LEVEL 5 & P4

LEVEL 6 & P5

LEVEL 7

DIAGRAM SECTION CUT

AT ZONES 13, 08, 03

L O

W E

R R

O

SW

E

LL

R O

A D

, S U

IT

E

O N

E M

A R

IE

T

T A

, G E

O R

G

IA

P

H O

N E

F

A X

W

W W

.J A

E N

G

IN

E E

R

IN

G .N

E T

Professional Seal

These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018

Project No:

Drawn By:

Checked By:

Original Document Size = 36" x 48"

C

U se rs \j p a rk \D o cu m e n ts

\1

_S a va n n a h

C o n ve n ti o n _C e n te r_

E xi st in g J&

A _C e n tr a l_ R

JP

A R

K

.r vt

/1

/2

:4

:0

A

M

AV2-202

LEVEL 2 - FLOOR PLAN - ZONE

JP

LC/JD

18051

05/01/23AV BID SET

SI

T

C C

A U

D

IO

-V

IS

U A

L R

E N

O V

A T

IO

N

SA

V

A N

N A

H , G

E O

R G

IA

A U

D

IO

V

IS

U A

L S

Y

ST

E M

F

L O

O R

P L A

N

AV BID SET

FLOOR PLAN

1/8" = 1'-0" 1

FLOOR PLAN - LEVEL 2 - ZONE 2

AUDIO VSUAL CONTRACTOR TO PROVIDE AND INSTALL WALL

MOUNTED LOUDSPEAKERS.

ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ONE 1-

GANG BACK BOX FLUSH-MOUNTED IN WALL AT 120-INCHES A.F.F

TO CENTER AND ONE (1) 1-INCH CONDUIT , STUBBED UP TO

ACCESSIBLE CEILING FOR WALL LOUDSPEAKER.

CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT

CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE

INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE

PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND

INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-

ACCESSIBLE CEILING OR HARD CEILING AREAS.

KEY NOTES:

A. UTILIZE EXISTING CONDUIT OR PATHWAY AND RUN THROUGH

AV RACK ACCESS.

B. UTILIZE EXISTING POWER RECEPTACLE. AUDIO VISUAL

CONTRACTOR TO DETERMINE IF CIRCUIT IS DEDICATED AND IF

S4S4 S4S4S4S4S4S4 S4S4 S4S4 S4S4

S4S4 S4S4 S4S4 S4S4 S4S4 S4S4

S4S4

S4S4 S4S4

S4S4 S4S4

S4S4

S4S4 S4S4

S4S4

S4S4

S4S4

GEORGIA

INTERNATIONAL

GALLERY

RESTROOM- MEN

C3.406

RESTROOM-

WOMEN

RESTROOM-

WOMEN

BALLROOM

B.O.H.

1 2

(TYP.)

TO MAIN

EQUIPMENT

RACK ROOM

Z11-2.1 Z6-2.2

Z6-2.2 Z6-2.2 Z6-2.2

Z6-2.2

Z6-2.1

Z6-2.1

Z6-2.1

Z6-2.1

Z6-2.1

Z6-2.1

Z6-2.1

Z6-2.1

Z6-2.1

Z6-2.1

Z6-2.1

Z6-2.1

Z6-2.1

(TYP.)

(TYP.)

Z6-2.2

Z6-2.2

Z6-2.2

Z6-2.2

Z6-2.2

TO MAIN

EQUIPMENT

RACK ROOM

(TYP.)

TO MAIN

EQUIPMENT

RACK ROOM

(TYP.)

1 2

(TYP.)

1 2

(TYP.)

Z11-2.2

N

ZONE 08ZONE 13 ZONE 03

ZONE 07ZONE 12 ZONE 02

ZONE 06ZONE 11 ZONE 01

ZONE 09ZONE 14 ZONE 04

ZONE 10ZONE 15 ZONE 05

A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR

LEVEL 1

LEVEL 2 & P1

LEVEL 3 & P2

LEVEL 4 & P3

LEVEL 5 & P4

LEVEL 6 & P5

LEVEL 7

DIAGRAM SECTION CUT

AT ZONES 13, 08, 03

L O

W E

R R

O

SW

E

LL

R O

A D

, S U

IT

E

O N

E M

A R

IE

T

T A

, G E

O R

G

IA

P

H O

N E

F

A X

W

W W

.J A

E N

G

IN

E E

R

IN

G .N

E T

Professional Seal

These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018

Project No:

Drawn By:

Checked By:

Original Document Size = 36" x 48"

C

U se rs \j p a rk \D o cu m e n ts

\1

_S a va n n a h

C o n ve n ti o n _C e n te r_

E xi st in g J&

A _C e n tr a l_ R

JP

A R

K

.r vt

/1

/2

:4

:0

A

M

AV2-206

LEVEL 2 - FLOOR PLAN - ZONE

JP

LC/JD

18051

05/01/23AV BID SET

SI

T

C C

A U

D

IO

-V

IS

U A

L R

E N

O V

A T

IO

N

SA

V

A N

N A

H , G

E O

R G

IA

A U

D

IO

V

IS

U A

L S

Y

ST

E M

F

L O

O R

P L A

N

AV BID SET

FLOOR PLAN

1/8" = 1'-0" 1

FLOOR PLAN - LEVEL 2 - ZONE 6

AUDIO VSUAL CONTRACTOR TO PROVIDE AND INSTALL WALL

MOUNTED LOUDSPEAKERS.

ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ONE 1-

GANG BACK BOX FLUSH-MOUNTED IN WALL AT 120-INCHES A.F.F

TO CENTER AND ONE (1) 1-INCH CONDUIT , STUBBED UP TO

ACCESSIBLE CEILING FOR WALL LOUDSPEAKER.

CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT

CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE

INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE

PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND

INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-

ACCESSIBLE CEILING OR HARD CEILING AREAS.

KEY NOTES:

A. UTILIZE EXISTING CONDUIT OR PATHWAY AND RUN THROUGH

AV RACK ACCESS.

B. UTILIZE EXISTING POWER RECEPTACLE. AUDIO VISUAL

CONTRACTOR TO DETERMINE IF CIRCUIT IS DEDICATED AND IF

BALLROOM

KITCHEN / BOH

OPEN TO BELOW

AV

EX

AV

EX

N

ZONE 08ZONE 13 ZONE 03

ZONE 07ZONE 12 ZONE 02

ZONE 06ZONE 11 ZONE 01

ZONE 09ZONE 14 ZONE 04

ZONE 10ZONE 15 ZONE 05

A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR

LEVEL 1

LEVEL 2 & P1

LEVEL 3 & P2

LEVEL 4 & P3

LEVEL 5 & P4

LEVEL 6 & P5

LEVEL 7

DIAGRAM SECTION CUT

AT ZONES 13, 08, 03

L O

W E

R R

O

SW

E

LL

R O

A D

, S U

IT

E

O N

E M

A R

IE

T

T A

, G E

O R

G

IA

P

H O

N E

F

A X

W

W W

.J A

E N

G

IN

E E

R

IN

G .N

E T

Professional Seal

These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018

Project No:

Drawn By:

Checked By:

Original Document Size = 36" x 48"

C

U se rs \j p a rk \D o cu m e n ts

\1

_S a va n n a h

C o n ve n ti o n _C e n te r_

E xi st in g J&

A _C e n tr a l_ R

JP

A R

K

.r vt

/1

/2

:4

:0

A

M

AV2-207

LEVEL 2 - FLOOR PLAN - ZONE

JP

LC/JD

18051

05/01/23AV BID SET

SI

T

C C

A U

D

IO

-V

IS

U A

L R

E N

O V

A T

IO

N

SA

V

A N

N A

H , G

E O

R G

IA

A U

D

IO

V

IS

U A

L S

Y

ST

E M

F

L O

O R

P L A

N

AV BID SET

FLOOR PLAN

1/8" = 1'-0" 1

FLOOR PLAN - LEVEL 2 - ZONE 7

EXISTING AV WALL INTERFACE PLATE. AUDIO VISUAL

CONTRACTOR TO LEAVE IN EXISTING WALL INTERFACE PLATE.

KEY NOTES:

A. UTILIZE EXISTING CONDUIT OR PATHWAY AND RUN THROUGH

AV RACK ACCESS.

B. UTILIZE EXISTING POWER RECEPTACLE. AUDIO VISUAL

CONTRACTOR TO DETERMINE IF CIRCUIT IS DEDICATED AND IF

S4S4

S4S4

S4S4S4S4S4S4

S4S4S4S4

S4S4

S4S4

S4S4 S4S4S4S4

S4S4

S4S4 S4S4

S4S4 S4S4

GEORGIA

INTERNATIONAL

GALLERY

505TO MAIN

EQUIPMENT

RACK ROOM

1 2

Z11-2.1

Z11-2.1

Z11-2.1

Z11-2.1

Z11-2.1

Z11-2.1

Z11-2.1

Z11-2.1

Z11-2.1

Z11-2.1

Z11-2.2

Z11-2.2 Z11-2.2

Z11-2.2

Z11-2.2

Z11-2.2

Z11-2.2

Z11-2.2

TO MAIN

EQUIPMENT

RACK ROOM

N

ZONE 08ZONE 13 ZONE 03

ZONE 07ZONE 12 ZONE 02

ZONE 06ZONE 11 ZONE 01

ZONE 09ZONE 14 ZONE 04

ZONE 10ZONE 15 ZONE 05

A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR

LEVEL 1

LEVEL 2 & P1

LEVEL 3 & P2

LEVEL 4 & P3

LEVEL 5 & P4

LEVEL 6 & P5

LEVEL 7

DIAGRAM SECTION CUT

AT ZONES 13, 08, 03

L O

W E

R R

O

SW

E

LL

R O

A D

, S U

IT

E

O N

E M

A R

IE

T

T A

, G E

O R

G

IA

P

H O

N E

F

A X

W

W W

.J A

E N

G

IN

E E

R

IN

G .N

E T

Professional Seal

These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018

Project No:

Drawn By:

Checked By:

Original Document Size = 36" x 48"

C

U se rs \j p a rk \D o cu m e n ts

\1

_S a va n n a h

C o n ve n ti o n _C e n te r_

E xi st in g J&

A _C e n tr a l_ R

JP

A R

K

.r vt

/1

/2

:4

:1

A

M

AV2-211

LEVEL 2 - FLOOR PLAN - ZONE

JP

LC/JD

18051

05/01/23AV BID SET

SI

T

C C

A U

D

IO

-V

IS

U A

L R

E N

O V

A T

IO

N

SA

V

A N

N A

H , G

E O

R G

IA

A U

D

IO

V

IS

U A

L S

Y

ST

E M

F

L O

O R

P L A

N

AV BID SET

FLOOR PLAN

1/8" = 1'-0" 1

FLOOR PLAN - LEVEL 2 - ZONE 11

AUDIO VSUAL CONTRACTOR TO PROVIDE AND INSTALL WALL

MOUNTED LOUDSPEAKERS.

ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ONE 1-

GANG BACK BOX FLUSH-MOUNTED IN WALL AT 120-INCHES A.F.F

TO CENTER AND ONE (1) 1-INCH CONDUIT , STUBBED UP TO

ACCESSIBLE CEILING FOR WALL LOUDSPEAKER.

CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT

CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE

INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE

PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND

INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-

ACCESSIBLE CEILING OR HARD CEILING AREAS.

AUDIO VISUAL CONTRACTOR TO REMOVE EXISTING WALL

INTERFACE PLATE WITH CABLES AND INSTALL NEW FINISHED

CONNECTORIZED PLATE IN SAME LOCATION. REFERENCE PLATE

DETAILS. AUDIO VISUAL CONTRATOR TO UTILIZE EXISTING A 4-

GANG BACK BOX FOR PATHWAY ROUTE TO RACK ROOM.

KEY NOTES:

A. UTILIZE EXISTING CONDUIT OR PATHWAY AND RUN THROUGH

AV RACK ACCESS.

B. UTILIZE EXISTING POWER RECEPTACLE. AUDIO VISUAL

CONTRACTOR TO DETERMINE IF CIRCUIT IS DEDICATED AND IF

100.

CONCOURSE

CONCOURSE

PUBLIC STAIRS

CONCOURSE

MEETING ROOMS

106.

101.

PUBLIC STAIRS

B.O.H.

HALL A

C2.5

HALL B

#43

CONCOURSE

MEETING ROOMS

C3.390

MEETING ROOMS

C3.389

MEETING ROOMS

C3.388

CONCOURSE

B.O.H.

B.O.H.

B.O.H.

B.O.H.

255 LOCKER ROOM

C3.383

RESTROOM- MEN

RESTROOM-

WOMEN

B.O.H.

NEW CONSTRUCTION

N

ZONE 08ZONE 13 ZONE 03

ZONE 07ZONE 12 ZONE 02

ZONE 06ZONE 11 ZONE 01

ZONE 09ZONE 14 ZONE 04

ZONE 10ZONE 15 ZONE 05

A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR

LEVEL 1

LEVEL 2 & P1

LEVEL 3 & P2

LEVEL 4 & P3

LEVEL 5 & P4

LEVEL 6 & P5

LEVEL 7

DIAGRAM SECTION CUT

AT ZONES 13, 08, 03

L O

W E

R R

O

SW

E

LL

R O

A D

, S U

IT

E

O N

E M

A R

IE

T

T A

, G E

O R

G

IA

P

H O

N E

F

A X

W

W W

.J A

E N

G

IN

E E

R

IN

G .N

E T

Professional Seal

These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018

Project No:

Drawn By:

Checked By:

Original Document Size = 36" x 48"

C

U se rs \j p a rk \D o cu m e n ts

\1

_S a va n n a h

C o n ve n ti o n _C e n te r_

E xi st in g J&

A _C e n tr a l_ R

JP

A R

K

.r vt

/1

/2

:4

:1

A

M

AV3-100

LEVEL 1 - RCP - OVERALL

JP

LC/JD

18051

05/01/23AV BID SET

SI

T

C C

A U

D

IO

-V

IS

U A

L R

E N

O V

A T

IO

N

SA

V

A N

N A

H , G

E O

R G

IA

A U

D

IO

V

IS

U A

L S

Y

ST

E M

R

C P

AV BID SET

RCP

OVERALL RCP - LEVEL 1

S1

S1

S1

S1

S1

S1

S1

S1 S1

S1 S1

S1

S1

S1

PUBLIC STAIRS

RESTROOM- MEN

RESTROOM-

WOMEN

RESTROOM- MEN

C3.380

TYP.

TYP.

TYP.

TO MAIN

EQUIPMENT

RACK ROOM

TYP.

TO MAIN

EQUIPMENT

RACK ROOM

Z1-1.3

Z1-1.2 Z1-1.2

Z1-1.2 Z1-1.2

Z1-1.3

Z1-1.3

Z1-1.3

Z1-1.3

Z1-1.3

Z1-1.3

Z1-1.3

N

ZONE 08ZONE 13 ZONE 03

ZONE 07ZONE 12 ZONE 02

ZONE 06ZONE 11 ZONE 01

ZONE 09ZONE 14 ZONE 04

ZONE 10ZONE 15 ZONE 05

A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR

LEVEL 1

LEVEL 2 & P1

LEVEL 3 & P2

LEVEL 4 & P3

LEVEL 5 & P4

LEVEL 6 & P5

LEVEL 7

DIAGRAM SECTION CUT

AT ZONES 13, 08, 03

L O

W E

R R

O

SW

E

LL

R O

A D

, S U

IT

E

O N

E M

A R

IE

T

T A

, G E

O R

G

IA

P

H O

N E

F

A X

W

W W

.J A

E N

G

IN

E E

R

IN

G .N

E T

Professional Seal

These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018

Project No:

Drawn By:

Checked By:

Original Document Size = 36" x 48"

C

U se rs \j p a rk \D o cu m e n ts

\1

_S a va n n a h

C o n ve n ti o n _C e n te r_

E xi st in g J&

A _C e n tr a l_ R

JP

A R

K

.r vt

/1

/2

:4

:2

A

M

AV3-101

LEVEL 1 - RCP - ZONE 1

JP

LC/JD

18051

05/01/23AV BID SET

SI

T

C C

A U

D

IO

-V

IS

U A

L R

E N

O V

A T

IO

N

SA

V

A N

N A

H , G

E O

R G

IA

A U

D

IO

V

IS

U A

L S

Y

ST

E M

R

C P

AV BID SET

RCP

1/8" = 1'-0" 1

RCP - LEVEL 1 - ZONE 1

CEILING MOUNTED LOUDSPEAKER TYPE "S1". AUDIO VISUAL

INTEGRATOR TO PROVIDE AND ELECTRICAL CONTRACTOR TO

INSTALL LOUDSPEAKER BACK-CAN. INTERCONNECT

LOUDSPEAKERS WITH 1-INCH CONDUIT IF CEILING IS

INACCESSIBLE AND/OR STUB TO ACCESSIBLE CEILING IF

NECESSARY. COORDINATE EXACT LOCATION WITH ARCHITECT

AND/OR OWNER.

CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT

CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE

INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE

PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND

INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-

ACCESSIBLE CEILING OR HARD CEILING AREAS.

KEY NOTES:

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S1

S1

S1

S1

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

100.

CONCOURSE

CONCOURSE

CONCOURSE

MEETING ROOMS

106.

101.

PUBLIC STAIRS

B.O.H.

B.O.H.

B.O.H.

C4.CC

CONCOURSE

TYP.

TO MAIN

EQUIPMENT

RACK ROOM

TYP.

TYP.

TYP.

TO MAIN

EQUIPMENT

RACK ROOM

TYP.

TYP.

TO MAIN

EQUIPMENT

RACK ROOM

TYP.

TYP.

TO MAIN

EQUIPMENT

RACK ROOM

TYP.

TYP.

TO MAIN

EQUIPMENT

RACK ROOM

TYP.

TYP.

TO MAIN

EQUIPMENT

RACK ROOM

TYP.

TYP.

TO MAIN

EQUIPMENT

RACK ROOM

TYP.

TYP.

TO MAIN EQUIPMENT RACK

ROOM

Z1-1.3

Z2-1.2

Z2-1.2

Z2-1.2

Z2-1.2

Z2-1.2

Z2-1.2

Z2-1.3 Z2-1.3 Z2-1.3 Z2-1.3

Z2-1.3Z2-1.3Z2-1.3Z2-1.3

Z2-1.4 Z2-1.4 Z2-1.4 Z2-1.4

Z2-1.4Z2-1.4Z2-1.4Z2-1.4

Z2-1.2

Z2-1.5

Z2-1.5 Z2-1.5 Z2-1.5 Z2-1.5

Z2-1.5Z2-1.5Z2-1.5

Z2-1.2

Z2-1.2

Z2-1.2

Z2-1.7 Z2-1.7 Z2-1.7 Z2-1.7

Z2-1.6 Z2-1.6 Z2-1.6

Z2-1.6Z2-1.6Z2-1.6Z2-1.6

Z2-1.7 Z2-1.7 Z2-1.7 Z2-1.7

Z2-1.8 Z2-1.8 Z2-1.8 Z2-1.8

Z2-1.8Z2-1.8 Z2-1.8 Z2-1.8Z2-1.2Z1-1.2

Z1-1.2

Z2-1.2

Z1-1.2

Z1-1.2

Z2-1.2

Z2-1.9 Z2-1.9 Z2-1.9 Z2-1.9

Z2-1.9Z2-1.9Z2-1.9Z2-1.9

Z2-1.6

N

ZONE 08ZONE 13 ZONE 03

ZONE 07ZONE 12 ZONE 02

ZONE 06ZONE 11 ZONE 01

ZONE 09ZONE 14 ZONE 04

ZONE 10ZONE 15 ZONE 05

A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR

LEVEL 1

LEVEL 2 & P1

LEVEL 3 & P2

LEVEL 4 & P3

LEVEL 5 & P4

LEVEL 6 & P5

LEVEL 7

DIAGRAM SECTION CUT

AT ZONES 13, 08, 03

L O

W E

R R

O

SW

E

LL

R O

A D

, S U

IT

E

O N

E M

A R

IE

T

T A

, G E

O R

G

IA

P

H O

N E

F

A X

W

W W

.J A

E N

G

IN

E E

R

IN

G .N

E T

Professional Seal

These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018

Project No:

Drawn By:

Checked By:

Original Document Size = 36" x 48"

C

U se rs \j p a rk \D o cu m e n ts

\1

_S a va n n a h

C o n ve n ti o n _C e n te r_

E xi st in g J&

A _C e n tr a l_ R

JP

A R

K

.r vt

/1

/2

:4

:2

A

M

AV3-102

LEVEL 1 - RCP - ZONE 2

JP

LC/JD

18051

05/01/23AV BID SET

SI

T

C C

A U

D

IO

-V

IS

U A

L R

E N

O V

A T

IO

N

SA

V

A N

N A

H , G

E O

R G

IA

A U

D

IO

V

IS

U A

L S

Y

ST

E M

R

C P

AV BID SET

RCP

1/8" = 1'-0" 1

RCP - LEVEL 1 - ZONE 2

CEILING MOUNTED LOUDSPEAKER TYPE "S1". AUDIO VISUAL

INTEGRATOR TO PROVIDE AND ELECTRICAL CONTRACTOR TO

INSTALL LOUDSPEAKER BACK-CAN. INTERCONNECT

LOUDSPEAKERS WITH 1-INCH CONDUIT IF CEILING IS

INACCESSIBLE AND/OR STUB TO ACCESSIBLE CEILING IF

NECESSARY. COORDINATE EXACT LOCATION WITH ARCHITECT

AND/OR OWNER.

CEILING MOUNTED LOUDSPEAKER "S2". AUDIO VISUAL

CONTRACTOR SHALL PROVIDE AND INSTALL IN-CEILING

MOUNTED LOUDSPEAKER AT LOCATION SHOWN. CONFIRM FINAL

COLOR WITH ARCHITECT.

CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT

CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE

INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE

PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND

INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-

ACCESSIBLE CEILING OR HARD CEILING AREAS.

KEY NOTES:

S1

S1

S1 S1

CONCOURSE

RESTROOM- MEN

RESTROOM-

WOMEN

HALL A

C2.5

B.O.H.

C3.76

RESTROOM- MEN

RESTROOM-

WOMEN

STORAGE

PUBLIC STAIRS

RESTROOM- MEN

RESTROOM-

WOMEN

CONCOURSE

RIVER CONCOURSE

TO MAIN

EQUIPMENT

RACK ROOM

TYP.

TYP.

TO MAIN

EQUIPMENT

RACK ROOM

Z1-1.2

Z1-1.2

Z1-1.2

Z1-1.2

Z1-1.2

Z1-1.2

N

ZONE 08ZONE 13 ZONE 03

ZONE 07ZONE 12 ZONE 02

ZONE 06ZONE 11 ZONE 01

ZONE 09ZONE 14 ZONE 04

ZONE 10ZONE 15 ZONE 05

A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR

LEVEL 1

LEVEL 2 & P1

LEVEL 3 & P2

LEVEL 4 & P3

LEVEL 5 & P4

LEVEL 6 & P5

LEVEL 7

DIAGRAM SECTION CUT

AT ZONES 13, 08, 03

L O

W E

R R

O

SW

E

LL

R O

A D

, S U

IT

E

O N

E M

A R

IE

T

T A

, G E

O R

G

IA

P

H O

N E

F

A X

W

W W

.J A

E N

G

IN

E E

R

IN

G .N

E T

Professional Seal

These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018

Project No:

Drawn By:

Checked By:

Original Document Size = 36" x 48"

C

U se rs \j p a rk \D o cu m e n ts

\1

_S a va n n a h

C o n ve n ti o n _C e n te r_

E xi st in g J&

A _C e n tr a l_ R

JP

A R

K

.r vt

/1

/2

:4

:2

A

M

AV3-106

LEVEL 1 - RCP - ZONE 6

JP

LC/JD

18051

05/01/23AV BID SET

SI

T

C C

A U

D

IO

-V

IS

U A

L R

E N

O V

A T

IO

N

SA

V

A N

N A

H , G

E O

R G

IA

A U

D

IO

V

IS

U A

L S

Y

ST

E M

R

C P

AV BID SET

FLOOR PLAN

1/8" = 1'-0" 1

RCP - LEVEL 1 - ZONE 6

CEILING MOUNTED LOUDSPEAKER TYPE "S1". AUDIO VISUAL

INTEGRATOR TO PROVIDE AND ELECTRICAL CONTRACTOR TO

INSTALL LOUDSPEAKER BACK-CAN. INTERCONNECT

LOUDSPEAKERS WITH 1-INCH CONDUIT IF CEILING IS

INACCESSIBLE AND/OR STUB TO ACCESSIBLE CEILING IF

NECESSARY. COORDINATE EXACT LOCATION WITH ARCHITECT

AND/OR OWNER.

CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT

CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE

INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE

PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND

INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-

ACCESSIBLE CEILING OR HARD CEILING AREAS.

KEY NOTES:

S2

S2 S2

S2

S2

S2

S1

S1 S1

S1

S1 S1

S1S1

S2 S2S2 S2

CONCOURSE

LOCKER ROOM

C3.387

TYP.

TO MAIN

EQUIPMENT

RACK ROOM

TYP.

TYP.

TO MAIN

EQUIPMENT

RACK ROOM

TYP.

BOARDROOM -

JASPER

BOARDROOM-

GWINNETT

BOARDROOM-

GREENE BOARDROOM-

PULASKI

TYP.

TO MAIN

EQUIPMENT

RACK ROOM

TYP.

TYP.

TO MAIN

EQUIPMENT

RACK ROOM

TYP.

Z11-1.5 Z11-1.5

Z11-1.5Z11-1.5

Z11-1.2 Z11-1.2 Z11-1.3 Z11-1.3 Z11-1.4 Z11-1.4

Z1-1.2 Z1-1.2

Z1-1.2 Z1-1.2

Z1-1.2

Z1-1.2 Z1-1.2

Z1-1.2

TO MAIN

EQUIPMENT

RACK ROOM3

TYP.

N

ZONE 08ZONE 13 ZONE 03

ZONE 07ZONE 12 ZONE 02

ZONE 06ZONE 11 ZONE 01

ZONE 09ZONE 14 ZONE 04

ZONE 10ZONE 15 ZONE 05

A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR

LEVEL 1

LEVEL 2 & P1

LEVEL 3 & P2

LEVEL 4 & P3

LEVEL 5 & P4

LEVEL 6 & P5

LEVEL 7

DIAGRAM SECTION CUT

AT ZONES 13, 08, 03

L O

W E

R R

O

SW

E

LL

R O

A D

, S U

IT

E

O N

E M

A R

IE

T

T A

, G E

O R

G

IA

P

H O

N E

F

A X

W

W W

.J A

E N

G

IN

E E

R

IN

G .N

E T

Professional Seal

These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018

Project No:

Drawn By:

Checked By:

Original Document Size = 36" x 48"

C

U se rs \j p a rk \D o cu m e n ts

\1

_S a va n n a h

C o n ve n ti o n _C e n te r_

E xi st in g J&

A _C e n tr a l_ R

JP

A R

K

.r vt

/1

/2

:4

:2

A

M

AV3-111

LEVEL 1 - RCP - ZONE 11

JP

LC/JD

18051

05/01/23AV BID SET

SI

T

C C

A U

D

IO

-V

IS

U A

L R

E N

O V

A T

IO

N

SA

V

A N

N A

H , G

E O

R G

IA

A U

D

IO

V

IS

U A

L S

Y

ST

E M

R

C P

AV BID SET

FLOOR PLAN

1/8" = 1'-0" 1

RCP - LEVEL 1 - ZONE 11

CEILING MOUNTED LOUDSPEAKER TYPE "S1". AUDIO VISUAL

INTEGRATOR TO PROVIDE AND ELECTRICAL CONTRACTOR TO

INSTALL LOUDSPEAKER BACK-CAN. INTERCONNECT

LOUDSPEAKERS WITH 1-INCH CONDUIT IF CEILING IS

INACCESSIBLE AND/OR STUB TO ACCESSIBLE CEILING IF

NECESSARY. COORDINATE EXACT LOCATION WITH ARCHITECT

AND/OR OWNER.

CEILING MOUNTED LOUDSPEAKER "S2". AUDIO VISUAL

CONTRACTOR SHALL PROVIDE AND INSTALL IN-CEILING

MOUNTED LOUDSPEAKER AT LOCATION SHOWN. CONFIRM FINAL

COLOR WITH ARCHITECT.

CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT

CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE

INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE

PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND

INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-

ACCESSIBLE CEILING OR HARD CEILING AREAS.

KEY NOTES:

S1 S1

S1

S1S1

B.O.H.

B.O.H.

B.O.H.

B.O.H.

255 LOCKER ROOM

C3.383

LOCKER ROOM

C3.387

TYP.

TO MAIN

EQUIPMENT

RACK ROOM

TYP.

B.O.H.

B.O.H.

Z1-1.2

Z1-1.2 Z1-1.2

Z1-1.2

Z1-1.2 Z1-1.2 Z1-1.2

N

ZONE 08ZONE 13 ZONE 03

ZONE 07ZONE 12 ZONE 02

ZONE 06ZONE 11 ZONE 01

ZONE 09ZONE 14 ZONE 04

ZONE 10ZONE 15 ZONE 05

A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR

LEVEL 1

LEVEL 2 & P1

LEVEL 3 & P2

LEVEL 4 & P3

LEVEL 5 & P4

LEVEL 6 & P5

LEVEL 7

DIAGRAM SECTION CUT

AT ZONES 13, 08, 03

L O

W E

R R

O

SW

E

LL

R O

A D

, S U

IT

E

O N

E M

A R

IE

T

T A

, G E

O R

G

IA

P

H O

N E

F

A X

W

W W

.J A

E N

G

IN

E E

R

IN

G .N

E T

Professional Seal

These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018

Project No:

Drawn By:

Checked By:

Original Document Size = 36" x 48"

C

U se rs \j p a rk \D o cu m e n ts

\1

_S a va n n a h

C o n ve n ti o n _C e n te r_

E xi st in g J&

A _C e n tr a l_ R

JP

A R

K

.r vt

/1

/2

:4

:3

A

M

AV3-112

LEVEL 1 - RCP - ZONE 12

JP

LC/JD

18051

05/01/23AV BID SET

SI

T

C C

A U

D

IO

-V

IS

U A

L R

E N

O V

A T

IO

N

SA

V

A N

N A

H , G

E O

R G

IA

A U

D

IO

V

IS

U A

L S

Y

ST

E M

R

C P

AV BID SET

FLOOR PLAN

1/8" = 1'-0" 1

RCP - LEVEL 1 - ZONE 12

CEILING MOUNTED LOUDSPEAKER TYPE "S1". AUDIO VISUAL

INTEGRATOR TO PROVIDE AND ELECTRICAL CONTRACTOR TO

INSTALL LOUDSPEAKER BACK-CAN. INTERCONNECT

LOUDSPEAKERS WITH 1-INCH CONDUIT IF CEILING IS

INACCESSIBLE AND/OR STUB TO ACCESSIBLE CEILING IF

NECESSARY. COORDINATE EXACT LOCATION WITH ARCHITECT

AND/OR OWNER.

CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT

CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE

INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE

PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND

INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-

ACCESSIBLE CEILING OR HARD CEILING AREAS.

KEY NOTES:

B.O.H.

EAST

CONCOURSE

20308

GEORGIA

INTERNATIONAL

GALLERY

BALLROOM

BALLROOM

BALLROOM

GEORGIA

INTERNATIONAL

GALLERY

PARKING

20815

NEW CONSTRUCTION

N

ZONE 08ZONE 13 ZONE 03

ZONE 07ZONE 12 ZONE 02

ZONE 06ZONE 11 ZONE 01

ZONE 09ZONE 14 ZONE 04

ZONE 10ZONE 15 ZONE 05

A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR

LEVEL 1

LEVEL 2 & P1

LEVEL 3 & P2

LEVEL 4 & P3

LEVEL 5 & P4

LEVEL 6 & P5

LEVEL 7

DIAGRAM SECTION CUT

AT ZONES 13, 08, 03

L O

W E

R R

O

SW

E

LL

R O

A D

, S U

IT

E

O N

E M

A R

IE

T

T A

, G E

O R

G

IA

P

H O

N E

F

A X

W

W W

.J A

E N

G

IN

E E

R

IN

G .N

E T

Professional Seal

These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018

Project No:

Drawn By:

Checked By:

Original Document Size = 36" x 48"

C

U se rs \j p a rk \D o cu m e n ts

\1

_S a va n n a h

C o n ve n ti o n _C e n te r_

E xi st in g J&

A _C e n tr a l_ R

JP

A R

K

.r vt

/1

/2

:4

:4

A

M

AV3-200

LEVEL 2 - RCP - OVERALL

JP

LC/JD

18051

05/01/23AV BID SET

SI

T

C C

A U

D

IO

-V

IS

U A

L R

E N

O V

A T

IO

N

SA

V

A N

N A

H , G

E O

R G

IA

A U

D

IO

V

IS

U A

L S

Y

ST

E M

R

C P

AV BID SET

FLOOR PLAN

1" = 20'-0" 1

OVERALL RCP - LEVEL 2

S6

S6

S6

S6

S6

S6

S6

S6

S6

S6 S6

S6

S6

S6

S6

S6

S3

S1

S4S4

GEORGIA

INTERNATIONAL

GALLERY

TO MAIN

EQUIPMENT

RACK ROOM

TYP.

TO MAIN

EQUIPMENT

RACK ROOM

TYP.

Z2-2.5

Z7-1.1

Z2-2.5

Z2-2.2

Z1-2.5

Z1-2.5

Z1-2.5

Z1-2.5

Z1-2.5

Z1-2.5

Z1-2.5

Z1-2.5

Z1-2.5

Z1-2.5

Z1-2.5

Z1-2.5

Z1-2.4

Z1-2.4

Z1-2.4

Z1-2.4

Z1-2.4

N

ZONE 08ZONE 13 ZONE 03

ZONE 07ZONE 12 ZONE 02

ZONE 06ZONE 11 ZONE 01

ZONE 09ZONE 14 ZONE 04

ZONE 10ZONE 15 ZONE 05

A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR

LEVEL 1

LEVEL 2 & P1

LEVEL 3 & P2

LEVEL 4 & P3

LEVEL 5 & P4

LEVEL 6 & P5

LEVEL 7

DIAGRAM SECTION CUT

AT ZONES 13, 08, 03

L O

W E

R R

O

SW

E

LL

R O

A D

, S U

IT

E

O N

E M

A R

IE

T

T A

, G E

O R

G

IA

P

H O

N E

F

A X

W

W W

.J A

E N

G

IN

E E

R

IN

G .N

E T

Professional Seal

These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018

Project No:

Drawn By:

Checked By:

Original Document Size = 36" x 48"

C

U se rs \j p a rk \D o cu m e n ts

\1

_S a va n n a h

C o n ve n ti o n _C e n te r_

E xi st in g J&

A _C e n tr a l_ R

JP

A R

K

.r vt

/1

/2

:4

:4

A

M

AV3-201

LEVEL 2- RCP - ZONE 1

JP

LC/JD

18051

05/01/23AV BID SET

SI

T

C C

A U

D

IO

-V

IS

U A

L R

E N

O V

A T

IO

N

SA

V

A N

N A

H , G

E O

R G

IA

A U

D

IO

V

IS

U A

L S

Y

ST

E M

R

C P

AV BID SET

FLOOR PLAN

1/8" = 1'-0" 1

RCP - LEVEL 2 - ZONE 1

CEILING MOUNTED LOUDSPEAKER TYPE "S1". AUDIO VISUAL

INTEGRATOR TO PROVIDE AND ELECTRICAL CONTRACTOR TO

INSTALL LOUDSPEAKER BACK-CAN. INTERCONNECT

LOUDSPEAKERS WITH 1-INCH CONDUIT IF CEILING IS

INACCESSIBLE AND/OR STUB TO ACCESSIBLE CEILING IF

NECESSARY. COORDINATE EXACT LOCATION WITH ARCHITECT

AND/OR OWNER.

CEILING MOUNTED PENDANT SPEAKER TYPE "S3" . ELECTRICAL

CONTACTOR SHALL PROVIDE AND INSTALL A SURFACE MOUNTED

SINGLE GANG BACK BOX CAPABLE OF SUPPORTING A 11.5

POUND PENDANT SPEAKER. COORDINATE LOUDSPAKER

LOCATION WITH LIGHT FIXTURE AND DIFFUSER LOCATIONS.

COORDINATE FINISH COLOR WITH ARCHITECT. AUDIO VISUAL

CONTRACTOR TO SUSPEND LOUDSPEAKER USING AIRCRAFT

CABLE. PAINT CABLE TO MATCH CEILING FINISH.

CEILING FLOWN LOUDSPEAKERS PROVIDED AND INSTALLED BY

AUDIO VISUAL CONTRACTOR. ALL LOUDSPEAKER FINISHES,

CABLING AND RIGGING HARDWARE SHALL BE COLORED 'WHITE'.

LOUDSPEAKER SHALL BE INSTALLED IN FULL COMPLIANCE WITH

RIGGING METHODS APPROVED BY A STRUCTURAL ENGINEER.

PROFESSIONAL RIGGING HARDWARE AND FORGED EYEBOLTS

SHALL BE UTILIZED AND SHALL BE RATED FOR FIVE TIMES THE

ACTUAL LOAD. HARDWARE AND CABLES SHALL BE PRE-

MANUFACTURED FROM ATM, POLAR FOCUS, OR OTHER RIGGING

MANUFACTURER AS APPROVED. CRIMP CONNECTIONS MADE IN

THE FIELD SHALL BE INSPECTED BY A CERTIFIED RIGGING

PROFESSIONAL. RIGGING SHALL INCLUDE CAPABILITY FOR

ADJUSTMENT OF VERTICAL LOUDSPEAKER AIMING ANGLE.

CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT

CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE

INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE

PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND

INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-

ACCESSIBLE CEILING OR HARD CEILING AREAS.

HIGH CEILING MOUNTED LOUDSPEAKER "S6". AUDIO VISUAL

CONTRACTOR SHALL PROVIDE AND INSTALL IN-CEILING

MOUNTED LOUDSPEAKER AT LOCATION SHOWN. CONFIRM FINAL

COLOR WITH ARCHITECT.

KEY NOTES:

S1S1

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .