SITCC EXISTING_AV_BID SET_05012023.pdf
PDF 9 MB Posted
- Attached to
- Audio Visual
- Solicitation number
- PE-92200-RFP-2025-000000031
- Issued by
- Chatham County, Georgia
About this file
The document is a set of drawings and specifications for an audio visual (AV) systems renovation project for the Savannah International Trade and Convention Center (SITCC) in Savannah, Georgia. The project scope includes the installation of new AV infrastructure, equipment, and systems throughout the facility, including meeting rooms, boardrooms, the ballroom, and the Oglethorpe Auditorium. The drawings provide detailed information on the required AV components, cabling, and mounting locations. The project is being procured by the Georgia World Congress Center Authority, which oversees the SITCC facility. The AV bid set was issued on May 1, 2023, and responses are due from specialized AV services firms.
The drawings indicate the AV contractor will be responsible for providing and installing various ceiling and wall-mounted speakers, wall interface plates, control panels, and other AV equipment as specified. The project will be funded through the Authority's capital improvement program, though the specific budget amount is not provided. The project will renovate the existing AV systems and is not expected to have any incumbent AV services provider.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ADDENDUM One June 2024.pdf | ||
| Question from previous ADDENDUM 1.pdf | ||
| As Built Two.pdf | ||
| Audio Visual RFP Savannah July 2024.pdf | ||
| Sign in Sheet AV July 2024.pdf | ||
| As Built One.pdf | ||
| As Built Three.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SUBMITTED ON: MAY 01, 2023
SAVANNAH, GEORGIA 31421
SAVANNAH ITCC - EXISTING FACILITY
AUDIO-VISUAL SYSTEMS
GENERAL NOTES:
A. ELECTRICAL CONTRACTOR TO INSTALL PULL STRINGS IN ALL CONDUIT.
B. ELECTRICAL CONTRACTOR TO TERMINATE ALL CONDUIT STUB-OUT AND SLEEVES WITH PLASTIC BUSHINGS.
C. NO MORE THAN THREE(3) QUARTER BENDS OR 200 DEGREES OF CONDUIT SHALL BE INSTALLED BETWEEN PULL
BOXES.
D. GENERAL CONTRACTOR TO PROVIDE WALL BLOCKING AT ALL FLAT PANEL LOCATIONS.
E. ALL FREE-RUN CABLING SHALL BE SEPARATED BY SIGNAL TYPE. PROVIDE 12" MINIMUM SPACING BETWEEN
LOUDSPEAKER CABLES, DIGITAL AV CABLES, AND ANALOG MICROPHONE CABLES.
F. ROUTE CABLING THROUGH UNDERFLOOR RACEWAY SYSTEM IN SPACES WHERE A RAISED ACCESS FLOOR IS
AVAILABLE.
G. ALL AV CABLING INSTALLED BELOW RAISED ACCESS FLOOR SHALL BE SUPPORTED ON J-HOOKS OR RINGS SPACED
AT 4' ON CENTERS MAXIMUM. DO NOT ALLOW CABLING TO CONTACT CONCRETE SLAB.
ELECTRICAL CONDUIT ROUGH-IN LEGEND:
FLAT PANEL DISPLAY MOUNTING SYSTEM WITH SPEAKERS (IF REQUIRED) SEE FLOOR PLANS FOR POWER AND
INTERFACE REQUIREMENTS. PROVIDE A POWER RECEPTACLE AT EACH DISPLAY LOCATION.
AUDIO VISUAL CEILING LOUDSPEAKER . AUDIO VISUAL CONTRACTOR TO PROVIDE MANUFACTURER'S BACK BOX AND MOUNTING ACCESSORIES FOR ALL LOCATIONS AS SHOWN ON PLANS. COORDINATE MOUNTING
LOCATION WITH MECHANICAL AND LIGHTING. INSTALLS IN CEILING GRID.
• ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL 3/4" CONDUIT BETWEEN LOUDSPEAKER BOXES IN HARD
CEILING SPACES AND/OR LOCATIONS THAT ARE INACCESSIBLE. ROUTE CONDUIT TO ACCESSIBLE CEILING
SPACES VIA PASS-THRU SLEEVES.
20 VOLT DUPLEX RECEPTACLE NEMA 5-20R. PROVIDED BY ELECTRICAL CONTRACTOR. SEE PLANS AND DETAILS
FOR LOCATIONS. ELEVATION IS AT 18" AFF OR AS NOTED ON PLANS.
DATA OUTLET. BACK BOX PROVIDED BY ELECTRICAL CONTRACTOR. SEE PLANS AND DETAILS FOR LOCATIONS AND QUANTITIES. ELEVATION IS AT 18" AFF OR AS NOTED ON PLANS. REFERENCE TELECOM DRAWINGS FOR
ROUGH-IN REQUIREMENTS.
• #SUBSCRIPT DETAILS NUMBER OF DATA DROPS PER LOCATION.
TELEVISION OUTLET WITH ONE DATA OUTLET, ONE VIDEO OVER IP OUTLET, AND CATV OUTLET. BACK BOX PROVIDED BY ELECTRICAL CONTRACTOR. SEE PLANS AND DETAILS FOR LOCATIONS AND QUANTITIES.
ELEVATION IS AT 18" AFF OR AS NOTED ON PLANS. REFERENCE TELECOM DRAWINGS FOR ROUGH-IN
REQUIREMENTS.
CATV OUTLET WITH ONE DATA OUTLET. BACK BOX PROVIDED BY ELECTRICAL CONTRACTOR. SEE PLANS AND DETAILS FOR LOCATIONS AND QUANTITIES. ELEVATION IS AT 18" AFF OR AS NOTED ON PLANS. REFERENCE
TELECOM DRAWINGS FOR ROUGH-IN REQUIREMENTS.
WALL MOUNTED CONTROL PANEL. REFERENCE FLOOR PLANS FOR LOCATION.
• ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL TWO-GANG BACK BOX MOUNTED AT 42-INCHES AFF
WITH CONDUITS AS SHOWN ON PLANS.
WALL MOUNTED INTERFACE CONNECTION PLATE. REFERENCE FLOOR PLANS FOR LOCATION.
• INP1 - UTILIZE EXISITING BACK BOX. SEE EACH SEET GENERAL NOTE.
• INP2 - UTILIZE EXISITING BACK BOX. SEE EACH SEET GENERAL NOTE.
• INP3 - UTILIZE EXISITING BACK BOX. SEE EACH SEET GENERAL NOTE.
• INP4 - UTILIZE EXISITING BACK BOX. SEE EACH SEET GENERAL NOTE.
SHEET LEGEND:
ABBREVIATION LEGEND:
A. LAN - LOCAL AREA NETWORK
B. NET - FACILITY COMPUTER NETWORK
C. RJ45 - EIGHT POSITION MODULAR PLUG AND JACK UTILIZED FOR TWISTED-PAIR CABLE CONNECTIONS
D. SC - FIBER OPTIC CABLE CONNECTOR FORM FACTOR
E. VOIP - VOICE OVER INTERNET PROTOCOL (IP) TELEPHONE SYSTEM
F. POE - POWER OVER ETHERNET
G. HDMI - HIGH-DEFINITION MULTIMEDIA INTERFACE DIGITAL VIDEO STANDARD
H. AEC - ACOUSTIC ECHO CANCELING MICROPHONE INPUT
I. PGM - PROGRAM AUDIO OR VIDEO
J. RS232 - UNBALANCED SERIAL CONTROL INTERFACE STANDARD
K. CNTR - CONTROL INPUT OR OUTPUT
L. OFE - OWNER FURNISHED EQUIPMENT
DEVICE LEGEND:
FLAT PANEL DISPLAY MOUNTING SYSTEM WITH INTEGRAL LOUDSPEAKER (IF REQUIRED, SEE FLOOR PLANS). SEE MOUNTED HEIGHTS AT XX"AFF TO CENTER OF SCREEN - SIZE DISPLAY AS INDICATED ON FLOOR PLANS.
COORDINATE EXACT LOCATION AS INDICATED ON FLOOR PLANS. COORDINATE MOUNTING WITH
ARCHITECTURAL AND FURNITURE LOCATIONS. SEE FLOOR PLANS FOR POWER, WALL BLOCKING, AND
INTERFACE REQUIREMENTS.
TYPE "S1" RECESSED CEILING LOUDSPEAKER PROVIDED AND INSTALLED BY AUDIO VISUAL CONTRACTOR.
SPEAKER TO BE WHITE IN COLOR, CONFIRM WITH ARCHITECT.
TYPE "S2" RECESSED HIGH-CEILING LOUDSPEAKER PROVIDED AND INSTALLED BY AUDIO VISUAL CONTRACTOR.
SPEAKER TO BE WHITE IN COLOR, CONFIRM WITH ARCHITECT.
TYPE "S3" PENDANT HIGH-LOUDSPEAKER PROVIDED AND INSTALLED BY AUDIO VISUAL CONTRACTOR. SPEAKER
TO BE WHITE IN COLOR, CONFIRM WITH ARCHITECT.
TYPE "S4" WALL MOUNTED LOUDSPEAKER PROVIDED AND INSTALLED BY AUDIO VISUAL CONTRACTOR.
SPEAKER TO BE WHITE IN COLOR, CONFIRM WITH ARCHITECT.
TYPE "S5" HORN LOADED PAGING LOUDSPEAKER PROVIDED AND INSTALLED BY AUDIO VISUAL CONTRACTOR.
SPEAKER TO BE WHITE IN COLOR, CONFIRM WITH ARCHITECT.
TYPE "S6" ABOVE FINISHED CEILING DUAL-WOOFER/HORN LOUDSPEAKER PROVIDED AND INSTALLED BY
AUDIO VISUAL CONTRACTOR. SPEAKER TO BE BLACK IN COLOR, CONFIRM WITH ARCHITECT.
TYPE "S7" WALL MOUNTED LOUDSPEAKER PROVIDED AND INSTALLED BY AUDIO VISUAL CONTRACTOR.
SPEAKER TO BE BLACK IN COLOR, CONFIRM WITH ARCHITECT.
WALL OR TABLE MOUNTED CONTROL PANEL. REFERENCE FLOOR PLANS FOR LOCATION.
• #SUBSCRIPT INDICATES MODEL TYPE. REFERENCE FLOOR PLAN & DETAILS FOR MODEL TYPE.
WALL MOUNTED INPUT INTERFACE CONNECTION PLATE. REFERENCE LARGE SCALE PLANS FOR LOCATION.
• #SUBSCRIPT INDICATES MODEL TYPE. REFERENCE DETAILS FOR ADDITIONAL INFORMATION.
WIRELESS MICROPHONE ANTENNA. REFERENCE FLOOR PLAN & CEILING PLANS FOR REQUIREMENTS.
INSTALL BELOW CEILING TILE USING TILE BRIDGE IN GRID OR SIMILAR MOUNTING DEVICE.
S1
AV
CTL#
AV
INP#
AV
ANT
S#
AV
CTL1
AV
INP#
TV
DS
D#
S2
S3
S4
S5
S6
S7
1 INTERNATIONAL DRIVE
L O
W E
R R
O
SW
E
LL
R O
A D
, S U
IT
E
O N
E M
A R
IE
T
T A
, G E
O R
G
IA
P
H O
N E
F
A X
W
W W
.J A
E N
G
IN
E E
R
IN
G .N
E T
Professional Seal
These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018
Project No:
Drawn By:
Checked By:
Original Document Size = 36" x 48"
C
U se rs \j p a rk \D o cu m e n ts
\1
_S a va n n a h
C o n ve n ti o n _C e n te r_
E xi st in g J&
A _C e n tr a l_ R
JP
A R
K
.r vt
/1
/2
:4
:1
A
M
AV0-000
COVER PAGE
JP
VP
18051
05/01/23AV BID SET
SI
T
C C
A U
D
IO
-V
IS
U A
L R
E N
O V
A T
IO
N
SA
V
A N
N A
H , G
E O
R G
IA
A U
D
IO
V
IS
U A
L S
Y
ST
E M
C
O V
E R
P A
G E
AV BID SET
AV0-000 COVER PAGE
AV2-100 OVERALL FLOOR PLAN - LEVEL 1
AV2-101 LEVEL 1 - FLOOR PLAN - ZONE 1
AV2-102 LEVEL 1 - FLOOR PLAN - ZONE 2
AV2-103 LEVEL 1 - FLOOR PLAN - ZONE 3
AV2-106 LEVEL 1 - FLOOR PLAN - ZONE 6
AV2-107 LEVEL 1 - FLOOR PLAN - ZONE 7
AV2-108 LEVEL 1 - FLOOR PLAN - ZONE 8
AV2-111 LEVEL 1 - FLOOR PLAN - ZONE 11
AV2-200 OVERALL FLOOR PLAN - LEVEL 2
AV2-202 LEVEL 2 - FLOOR PLAN - ZONE 2
AV2-206 LEVEL 2 - FLOOR PLAN - ZONE 6
AV2-207 LEVEL 2 - FLOOR PLAN - ZONE 7
AV2-211 LEVEL 2 - FLOOR PLAN - ZONE 11
AV3-100 LEVEL 1 - RCP - OVERALL
AV3-101 LEVEL 1 - RCP - ZONE 1
AV3-102 LEVEL 1 - RCP - ZONE 2
AV3-106 LEVEL 1 - RCP - ZONE 6
AV3-111 LEVEL 1 - RCP - ZONE 11
AV3-112 LEVEL 1 - RCP - ZONE 12
AV3-200 LEVEL 2 - RCP - OVERALL
AV3-201 LEVEL 2- RCP - ZONE 1
AV3-202 LEVEL 2 - RCP - ZONE 2
AV3-206 LEVEL 2 - RCP - ZONE 6
AV3-207 LEVEL 2 - RCP - ZONE 7
AV3-208 LEVEL 2 - RCP - ZONE 8
AV3-211 LEVEL 2 - RCP - ZONE 11
AV3-212 LEVEL 2 - RCP - ZONE 12
AV4-101 LARGE SCALES - BOARDROOMS
AV4-102 LARGE SCALES - MEETING ROOMS
AV4-103 LARGE SCALES - MEETING ROOMS, AV RACK ROOM
AV4-104 LARGE SCALES - OGLETHORPE AUDITORIUM
AV4-105 LARGE SCALES - BALLROOM
AV4-106 LARGE SCALES - MEETING ROOMS - LEVEL 2
AV5-101 ONE-LINE DIAGRAM - EXHIBIT TIE LINE
AV5-102 ONE-LINE DIAGRAM - MEETING ROOM TIE LINE
AV5-103 ONE-LINE DIAGRAM - MEETING ROOM TIE LINE
AV5-104 ONE-LINE DIAGRAM - BALLROOM TIE LINE
AV5-105 ONE-LINE DIAGRAM - BALLROOM
AV5-106 ONE-LINE DIAGRAM - EXHIBIT HALL AUDIO #1
AV5-107 ONE-LINE DIAGRAM - EXHIBIT HALL AUDIO #2
AV5-108 ONE-LINE DIAGRAM - EXHIBIT HALL AUDIO #3
AV5-109 ONE-LINE DIAGRAM - EXHIBIT HALL AUDIO #4
AV5-110 ONE-LINE DIAGRAM - CONTROL SYSTEM
AV5-111 ONE-LINE DIAGRAM - OGLETHORPE AUDITORIUM
AV5-112 ONE-LINE DIAGRAM - BOARDROOMS
AV5-113 ONE-LINE DIAGRAM - DS & RS
AV6-101 DETAILS
UP
RESTROOM-
WOMEN
10808
HALL A
C2.5
HALL B
#43
CONCOURSE
EAST LOBBY/
REGISTRATION
10309MECHANICAL
ROOM
B.O.H.
RESTAURANT
CAFE
439CONCOURSE
RECEPTION
STORAGE
CONCOURSE
B.O.H.
B.O.H.
C3.76
LOADING DOCK
209.
UNIFORM ISSUE
C3.386
PUBLIC STAIRS
PUBLIC STAIRS
LOADING DOCK
209.
LOADING DOCK
209.
B.O.H.
B.O.H.
AV4-103
STORAGE
B.O.H.
210.
B.O.H.
B.O.H.
HALL C
10804
TRUCK PARKING AV4-102
AV4-102
AV4-102
AV4-103
AV4-104
AV4-101
AV4-101
BOARDROOM-
GWINNETT
BOARDROOM-
GREENE
BOARDROOM-
PULASKI
BOARDROOM-
JASPER
MEETING ROOM
MEETING ROOM
MEETING ROOM
MEETING ROOM
MEETING ROOM
MEETING ROOM
MEETING ROOM
OGLETHORPE
AUDITORIUM
NEW CONSTRUCTION
CONCESSIONS
RIVER CONCOURCE
ROTUNDA
REGISTRATION
RECEPTION
AV4-103
MAIN EQUIPMENT RACK ROOM
AV EQUIPMENT RACK ROOM
DEDICATED FIBER OPTIC FOR DIGITAL AUDIO
NETWORK & CONTROL
6-STRAND SM BY AUDIO VISUAL CONTRACTOR
( REFER TO
TELECOM DRAWINGS FOR CONDUIT PATHWAY)
TO IDF/AV 10812
TO IDF/AV 10333
DEDICATED FIBER OPTIC FOR DIGITAL AUDIO
NETWORK & CONTROL
6-STRAND SM BY AUDIO VISUAL CONTRACTOR
( REFER TO
TELECOM DRAWINGS FOR CONDUIT
PATHWAY) DEDICATED FIBER OPTIC FOR DIGITAL
AUDIO NETWORK & CONTROL
6-STRAND SM BY AUDIO VISUAL
CONTRACTOR ( REFER TO
TELECOM DRAWINGS FOR CONDUIT
PATHWAY)
B.O.H.
N
ZONE 08ZONE 13 ZONE 03
ZONE 07ZONE 12 ZONE 02
ZONE 06ZONE 11 ZONE 01
ZONE 09ZONE 14 ZONE 04
ZONE 10ZONE 15 ZONE 05
A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR
LEVEL 1
LEVEL 2 & P1
LEVEL 3 & P2
LEVEL 4 & P3
LEVEL 5 & P4
LEVEL 6 & P5
LEVEL 7
DIAGRAM SECTION CUT
AT ZONES 13, 08, 03
L O
W E
R R
O
SW
E
LL
R O
A D
, S U
IT
E
O N
E M
A R
IE
T
T A
, G E
O R
G
IA
P
H O
N E
F
A X
W
W W
.J A
E N
G
IN
E E
R
IN
G .N
E T
Professional Seal
These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018
Project No:
Drawn By:
Checked By:
Original Document Size = 36" x 48"
C
U se rs \j p a rk \D o cu m e n ts
\1
_S a va n n a h
C o n ve n ti o n _C e n te r_
E xi st in g J&
A _C e n tr a l_ R
JP
A R
K
.r vt
/1
/2
:4
:2
A
M
AV2-100
OVERALL FLOOR PLAN - LEVEL
JP
VP
18051
05/01/23AV BID SET
SI
T
C C
A U
D
IO
-V
IS
U A
L R
E N
O V
A T
IO
N
SA
V
A N
N A
H , G
E O
R G
IA
A U
D
IO
V
IS
U A
L S
Y
ST
E M
F
L O
O R
P L A
N
AV BID SET
FLOOR PLAN
1" = 20'-0" 1
OVERALL FLOOR PLAN - LEVEL 1
S4S4
S4S4 S4S4 S4S4
S4S4
S4S4
S4S4
S4S4
S4S4
MEETING ROOMS
32"D
32"D
TYP.
7 AV
INP1
TO MAIN
EQUIPMENT
RACK ROOM
TYP.
TO MAIN
EQUIPMENT
RACK ROOM
TO MAIN
EQUIPMENT
RACK ROOM
EXISTING
VIDEO WALL
TO REMAIN
226"D
Z1-1.1 Z1-1.1 Z1-1.1
Z1-1.1
Z1-1.1
Z2-1.1
Z1-1.1
Z1-1.1
B.O.H.
N
ZONE 08ZONE 13 ZONE 03
ZONE 07ZONE 12 ZONE 02
ZONE 06ZONE 11 ZONE 01
ZONE 09ZONE 14 ZONE 04
ZONE 10ZONE 15 ZONE 05
A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR
LEVEL 1
LEVEL 2 & P1
LEVEL 3 & P2
LEVEL 4 & P3
LEVEL 5 & P4
LEVEL 6 & P5
LEVEL 7
DIAGRAM SECTION CUT
AT ZONES 13, 08, 03
L O
W E
R R
O
SW
E
LL
R O
A D
, S U
IT
E
O N
E M
A R
IE
T
T A
, G E
O R
G
IA
P
H O
N E
F
A X
W
W W
.J A
E N
G
IN
E E
R
IN
G .N
E T
Professional Seal
These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018
Project No:
Drawn By:
Checked By:
Original Document Size = 36" x 48"
C
U se rs \j p a rk \D o cu m e n ts
\1
_S a va n n a h
C o n ve n ti o n _C e n te r_
E xi st in g J&
A _C e n tr a l_ R
JP
A R
K
.r vt
/1
/2
:4
:2
A
M
AV2-101
LEVEL 1 - FLOOR PLAN - ZONE
JP
LC/JD
18051
05/01/23AV BID SET
SI
T
C C
A U
D
IO
-V
IS
U A
L R
E N
O V
A T
IO
N
SA
V
A N
N A
H , G
E O
R G
IA
A U
D
IO
V
IS
U A
L S
Y
ST
E M
F
L O
O R
P L A
N
AV BID SET
32-INCH ROOM SCHEDULING DISPLAY.
ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL A PASS &
SEYMOUR TV2M, BY LEGRAND, FOR AV BACKBOX. ALSO PROVIDE
AND INSTALL ONE (1) 120V/1-PHASE DUPLEX RECEPTACLE IN
SPACE PROVIDED BEHIND FLAT PANEL DISPLAY, ADJACENT
BRACKET LOCATION.
TELECOM CONTRACTOR TO PROVIDE AND INSTALL DATA
OUTLET(S) IN SPACE PROVIDED..
AUDIO VSUAL CONTRACTOR TO PROVIDE AND INSTALL WALL
MOUNTED LOUDSPEAKERS.
ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ONE 1-
GANG BACK BOX FLUSH-MOUNTED IN WALL AT 120-INCHES A.F.F
TO CENTER AND ONE (1) 1-INCH CONDUIT , STUBBED UP TO
ACCESSIBLE CEILING FOR WALL LOUDSPEAKER.
CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT
CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE
INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE
PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND
INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-
ACCESSIBLE CEILING OR HARD CEILING AREAS.
AUDIO VISUAL CONTRACTOR TO REMOVE EXISTING WALL
INTERFACE PLATE WITH CABLES AND INSTALL NEW FINISHED
CONNECTORIZED PLATE IN SAME LOCATION. REFERENCE PLATE
DETAILS. AUDIO VISUAL CONTRATOR TO UTILIZE EXISTING A 4-
GANG BACK BOX FOR PATHWAY ROUTE TO RACK ROOM.
KEY NOTES:
FLOOR PLAN
1/8" = 1'-0" 1
FLOOR PLAN - LEVEL 1 - ZONE 1
A. UTILIZE EXISTING CONDUIT OR PATHWAY AND RUN THROUGH
AV RACK ACCESS.
B. UTILIZE EXISTING POWER RECEPTACLE. AUDIO VISUAL
CONTRACTOR TO DETERMINE IF CIRCUIT IS DEDICATED AND IF
SECOND CIRCUIT IS REQUIRED.
GENERAL NOTES:
S4S4 S4S4
S4S4
S4S4 S4S4
S4S4
MEETING ROOMS
106.
101.
100.
1 2
TYP.
TO MAIN
EQUIPMENT
RACK ROOM
(1)1"C
65"D
DS
CONCESSIONS
AV
INP1
AV
INP1
AV
INP1
TO MAIN
EQUIPMENT
RACK ROOM
Z2-1.1
TYP.
TYP.
TYP.
Z2-1.1
Z2-1.1
Z2-1.1
Z2-1.1
Z2-1.1
Z2-1.1
Z2-1.1
B.O.H.
B.O.H.
N
ZONE 08ZONE 13 ZONE 03
ZONE 07ZONE 12 ZONE 02
ZONE 06ZONE 11 ZONE 01
ZONE 09ZONE 14 ZONE 04
ZONE 10ZONE 15 ZONE 05
A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR
LEVEL 1
LEVEL 2 & P1
LEVEL 3 & P2
LEVEL 4 & P3
LEVEL 5 & P4
LEVEL 6 & P5
LEVEL 7
DIAGRAM SECTION CUT
AT ZONES 13, 08, 03
L O
W E
R R
O
SW
E
LL
R O
A D
, S U
IT
E
O N
E M
A R
IE
T
T A
, G E
O R
G
IA
P
H O
N E
F
A X
W
W W
.J A
E N
G
IN
E E
R
IN
G .N
E T
Professional Seal
These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018
Project No:
Drawn By:
Checked By:
Original Document Size = 36" x 48"
C
U se rs \j p a rk \D o cu m e n ts
\1
_S a va n n a h
C o n ve n ti o n _C e n te r_
E xi st in g J&
A _C e n tr a l_ R
JP
A R
K
.r vt
/1
/2
:4
:2
A
M
AV2-102
LEVEL 1 - FLOOR PLAN - ZONE
JP
LC/JD
18051
05/01/23AV BID SET
SI
T
C C
A U
D
IO
-V
IS
U A
L R
E N
O V
A T
IO
N
SA
V
A N
N A
H , G
E O
R G
IA
A U
D
IO
V
IS
U A
L S
Y
ST
E M
F
L O
O R
P L A
N
AV BID SET
FLOOR PLAN
1/8" = 1'-0" 1
FLOOR PLAN - LEVEL 1 - ZONE 2
AUDIO VSUAL CONTRACTOR TO PROVIDE AND INSTALL WALL
MOUNTED LOUDSPEAKERS.
ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ONE 1-
GANG BACK BOX FLUSH-MOUNTED IN WALL AT 120-INCHES A.F.F
TO CENTER AND ONE (1) 1-INCH CONDUIT , STUBBED UP TO
ACCESSIBLE CEILING FOR WALL LOUDSPEAKER.
CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT
CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE
INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE
PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND
INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-
ACCESSIBLE CEILING OR HARD CEILING AREAS.
AUDIO VISUAL CONTRACTOR TO REMOVE EXISTING WALL
INTERFACE PLATE WITH CABLES AND INSTALL NEW FINISHED
CONNECTORIZED PLATE IN SAME LOCATION. REFERENCE PLATE
DETAILS. AUDIO VISUAL CONTRATOR TO UTILIZE EXISTING A 4-
GANG BACK BOX FOR PATHWAY ROUTE TO RACK ROOM.
65-INCH SIGNAGE DISPLAY. ELECTRICAL CONTRACTOR TO
PROVIDE AND INSTALL A PASS & SEYMOUR TV2M, BY LEGRAND,
FOR AV BACKBOX. ALSO PROVIDE AND INSTALL ONE (1) 120V/1-
PHASE DUPLEX RECEPTACLE IN SPACE PROVIDED BEHIND
FLAT PANEL DISPLAY AT 78" AFF. TELECOM CONTRACTOR TO
PROVIDE AND INSTALL DATA OUTLET(S) IN SPACE PROVIDED.
KEY NOTES:
A. UTILIZE EXISTING CONDUIT OR PATHWAY AND RUN THROUGH
AV RACK ACCESS.
B. UTILIZE EXISTING POWER RECEPTACLE. AUDIO VISUAL
CONTRACTOR TO DETERMINE IF CIRCUIT IS DEDICATED AND IF
SECOND CIRCUIT IS REQUIRED.
100.
EAST LOBBY/
REGISTRATION
10308
HALL C
10804
HALL B
#43
AV
EX
STAIR #22
10301
Z2-1.1
1 2 3
N
ZONE 08ZONE 13 ZONE 03
ZONE 07ZONE 12 ZONE 02
ZONE 06ZONE 11 ZONE 01
ZONE 09ZONE 14 ZONE 04
ZONE 10ZONE 15 ZONE 05
A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR
LEVEL 1
LEVEL 2 & P1
LEVEL 3 & P2
LEVEL 4 & P3
LEVEL 5 & P4
LEVEL 6 & P5
LEVEL 7
DIAGRAM SECTION CUT
AT ZONES 13, 08, 03
L O
W E
R R
O
SW
E
LL
R O
A D
, S U
IT
E
O N
E M
A R
IE
T
T A
, G E
O R
G
IA
P
H O
N E
F
A X
W
W W
.J A
E N
G
IN
E E
R
IN
G .N
E T
Professional Seal
These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018
Project No:
Drawn By:
Checked By:
Original Document Size = 36" x 48"
C
U se rs \j p a rk \D o cu m e n ts
\1
_S a va n n a h
C o n ve n ti o n _C e n te r_
E xi st in g J&
A _C e n tr a l_ R
JP
A R
K
.r vt
/1
/2
:4
:3
A
M
AV2-103
LEVEL 1 - FLOOR PLAN - ZONE
JP
LC/JD
18051
05/01/23AV BID SET
SI
T
C C
A U
D
IO
-V
IS
U A
L R
E N
O V
A T
IO
N
SA
V
A N
N A
H , G
E O
R G
IA
A U
D
IO
V
IS
U A
L S
Y
ST
E M
F
L O
O R
P L A
N
AV BID SET
FLOOR PLAN
1/8" = 1'-0" 1
FLOOR PLAN - LEVEL 1 - ZONE 3
A. UTILIZE EXISTING CONDUIT OR PATHWAY AND RUN THROUGH
AV RACK ACCESS.
B. UTILIZE EXISTING POWER RECEPTACLE. AUDIO VISUAL
CONTRACTOR TO DETERMINE IF CIRCUIT IS DEDICATED AND IF
SECOND CIRCUIT IS REQUIRED.
GENERAL NOTES:
AUDIO VSUAL CONTRACTOR TO PROVIDE AND INSTALL WALL
MOUNTED LOUDSPEAKERS.
ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ONE 1-
GANG BACK BOX FLUSH-MOUNTED IN WALL AT 120-INCHES A.F.F
TO CENTER AND ONE (1) 1-INCH CONDUIT , STUBBED UP TO
ACCESSIBLE CEILING FOR WALL LOUDSPEAKER.
CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT
CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE
INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE
PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND
INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-
ACCESSIBLE CEILING OR HARD CEILING AREAS.
EXISTING AV WALL INTERFACE PLATE. AUDIO VISUAL
CONTRACTOR TO LEAVE IN EXISTING WALL INTERFACE PLATE.
KEY NOTES:
S4S4S4S4 S4S4
S4S4
S4S4
S4S4 S4S4 S4S4 S4S4 S4S4 S4S4
S4S4 S4S4 S4S4 S4S4 S4S4
S4S4
S4S4
S4S4
STORAGE
B.O.H.
B.O.H.
RIVER CONCOURSE
4 AV
INP2
AV
INP2
TO MAIN
EQUIPMENT
RACK ROOM
Z1-1.1
Z6-1.1 Z6-1.1 Z6-1.1 Z6-1.1
Z6-1.1
Z6-1.1
Z6-1.1
Z6-1.1
Z6-1.1 Z6-1.1 Z6-1.1 Z6-1.1 Z6-1.1 Z6-1.1
Z6-1.2Z6-1.2Z6-1.2 Z6-1.2
Z6-1.2
2 4TYP.
TYP.
TYP.
TYP.
Z11-1.1
N
ZONE 08ZONE 13 ZONE 03
ZONE 07ZONE 12 ZONE 02
ZONE 06ZONE 11 ZONE 01
ZONE 09ZONE 14 ZONE 04
ZONE 10ZONE 15 ZONE 05
A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR
LEVEL 1
LEVEL 2 & P1
LEVEL 3 & P2
LEVEL 4 & P3
LEVEL 5 & P4
LEVEL 6 & P5
LEVEL 7
DIAGRAM SECTION CUT
AT ZONES 13, 08, 03
L O
W E
R R
O
SW
E
LL
R O
A D
, S U
IT
E
O N
E M
A R
IE
T
T A
, G E
O R
G
IA
P
H O
N E
F
A X
W
W W
.J A
E N
G
IN
E E
R
IN
G .N
E T
Professional Seal
These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018
Project No:
Drawn By:
Checked By:
Original Document Size = 36" x 48"
C
U se rs \j p a rk \D o cu m e n ts
\1
_S a va n n a h
C o n ve n ti o n _C e n te r_
E xi st in g J&
A _C e n tr a l_ R
JP
A R
K
.r vt
/1
/2
:4
:3
A
M
AV2-106
LEVEL 1 - FLOOR PLAN - ZONE
JP
LC/JD
18051
05/01/23AV BID SET
SI
T
C C
A U
D
IO
-V
IS
U A
L R
E N
O V
A T
IO
N
SA
V
A N
N A
H , G
E O
R G
IA
A U
D
IO
V
IS
U A
L S
Y
ST
E M
F
L O
O R
P L A
N
AV BID SET
FLOOR PLAN
1/8" = 1'-0" 1
FLOOR PLAN - LEVEL 1 - ZONE 6
A. UTILIZE EXISTING CONDUIT OR PATHWAY AND RUN THROUGH
AV RACK ACCESS.
B. UTILIZE EXISTING POWER RECEPTACLE. AUDIO VISUAL
CONTRACTOR TO DETERMINE IF CIRCUIT IS DEDICATED AND IF
SECOND CIRCUIT IS REQUIRED.
GENERAL NOTES:
AUDIO VSUAL CONTRACTOR TO PROVIDE AND INSTALL WALL
MOUNTED LOUDSPEAKERS.
ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ONE 1-
GANG BACK BOX FLUSH-MOUNTED IN WALL AT 120-INCHES A.F.F
TO CENTER AND ONE (1) 1-INCH CONDUIT , STUBBED UP TO
ACCESSIBLE CEILING FOR WALL LOUDSPEAKER.
CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT
CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE
INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE
PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND
INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-
ACCESSIBLE CEILING OR HARD CEILING AREAS.
AUDIO VISUAL CONTRACTOR TO REMOVE EXISTING WALL
INTERFACE PLATE WITH CABLES AND INSTALL NEW FINISHED
CONNECTORIZED PLATE IN SAME LOCATION. REFERENCE PLATE
DETAILS. AUDIO VISUAL CONTRATOR TO UTILIZE EXISTING A 4-
GANG BACK BOX FOR PATHWAY ROUTE TO RACK ROOM.
KEY NOTES:
S
S
S
S
HALL A
C2.5
HALL B
#43
B.O.H.
C3.76
LOADING DOCK
209.
LOADING DOCK
209.
B.O.H.
AV
INP1
AV
INP1
AV
INP1
AV
INP1
AV
INP1
AV
INP1
AV
INP1
AV
INP1
TO MAIN
EQUIPMENT
RACK ROOM
TYP.
TYP.
TYP.
FOR DANTE AUDIO & AUDIO NETWORK CABLING DISTANCE
BEYOND 90 METERS IN TOTAL CABLE LENGTH, CONTRACTOR TO
PROVIDE AND INSTALL POE EXTENDERS.
N
ZONE 08ZONE 13 ZONE 03
ZONE 07ZONE 12 ZONE 02
ZONE 06ZONE 11 ZONE 01
ZONE 09ZONE 14 ZONE 04
ZONE 10ZONE 15 ZONE 05
A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR
LEVEL 1
LEVEL 2 & P1
LEVEL 3 & P2
LEVEL 4 & P3
LEVEL 5 & P4
LEVEL 6 & P5
LEVEL 7
DIAGRAM SECTION CUT
AT ZONES 13, 08, 03
L O
W E
R R
O
SW
E
LL
R O
A D
, S U
IT
E
O N
E M
A R
IE
T
T A
, G E
O R
G
IA
P
H O
N E
F
A X
W
W W
.J A
E N
G
IN
E E
R
IN
G .N
E T
Professional Seal
These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018
Project No:
Drawn By:
Checked By:
Original Document Size = 36" x 48"
C
U se rs \j p a rk \D o cu m e n ts
\1
_S a va n n a h
C o n ve n ti o n _C e n te r_
E xi st in g J&
A _C e n tr a l_ R
JP
A R
K
.r vt
/1
/2
:4
:3
A
M
AV2-107
LEVEL 1 - FLOOR PLAN - ZONE
JP
LC/JD
18051
05/01/23AV BID SET
SI
T
C C
A U
D
IO
-V
IS
U A
L R
E N
O V
A T
IO
N
SA
V
A N
N A
H , G
E O
R G
IA
A U
D
IO
V
IS
U A
L S
Y
ST
E M
F
L O
O R
P L A
N
AV BID SET
FLOOR PLAN
1/8" = 1'-0" 1
FLOOR PLAN - LEVEL 1 - ZONE 7
AUDIO VISUAL CONTRACTOR TO REMOVE EXISTING WALL
INTERFACE PLATE WITH CABLES AND INSTALL NEW FINISHED
CONNECTORIZED PLATE IN SAME LOCATION. REFERENCE PLATE
DETAILS. AUDIO VISUAL CONTRATOR TO UTILIZE EXISTING A 4-
GANG BACK BOX FOR PATHWAY ROUTE TO RACK ROOM.
WALL MOUNTED LOUDSPEAKER "S5". ELECTRICAL CONTRACTOR
TO PROVIDE AND INSTALL ONE (1) - 1-GANG WALL BOX LOCATED
AT 96-INCHES AFF. SUB-UP ONE(1) 1-INCH CONDUIT TO
ACCESSIBLE CIEILING. SEE DETAIL DRAWINGS FOR ADDITIONAL
INFORMATION.
CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT
CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE
INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE
PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND
INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-
ACCESSIBLE CEILING OR HARD CEILING AREAS.
KEY NOTES:
A. UTILIZE EXISTING CONDUIT OR PATHWAY AND RUN THROUGH
AV RACK ACCESS.
B. UTILIZE EXISTING POWER RECEPTACLE. AUDIO VISUAL
CONTRACTOR TO DETERMINE IF CIRCUIT IS DEDICATED AND IF
SECOND CIRCUIT IS REQUIRED.
GENERAL NOTES:
S5
S
S
S
RESTROOM-
WOMEN
10808
LOADING DOCK
209.
LOADING DOCK
209.
HALL B
#43
HALL C
10804
LOADING DOCK
10806
BACK OF HOUSE
CORRIDOR
11AV
INP1
AV
INP1
TO MAIN
EQUIPMENT
RACK ROOM
TYP.
TYP.
Z12-1.1
Z12-1.1
Z12-1.1
Z12-1.1
TO IDF/AV
10812
(1)1-1/2"
TO IDF/AV
10333
(1)1-1/2"
N
ZONE 08ZONE 13 ZONE 03
ZONE 07ZONE 12 ZONE 02
ZONE 06ZONE 11 ZONE 01
ZONE 09ZONE 14 ZONE 04
ZONE 10ZONE 15 ZONE 05
A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR
LEVEL 1
LEVEL 2 & P1
LEVEL 3 & P2
LEVEL 4 & P3
LEVEL 5 & P4
LEVEL 6 & P5
LEVEL 7
DIAGRAM SECTION CUT
AT ZONES 13, 08, 03
L O
W E
R R
O
SW
E
LL
R O
A D
, S U
IT
E
O N
E M
A R
IE
T
T A
, G E
O R
G
IA
P
H O
N E
F
A X
W
W W
.J A
E N
G
IN
E E
R
IN
G .N
E T
Professional Seal
These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018
Project No:
Drawn By:
Checked By:
Original Document Size = 36" x 48"
C
U se rs \j p a rk \D o cu m e n ts
\1
_S a va n n a h
C o n ve n ti o n _C e n te r_
E xi st in g J&
A _C e n tr a l_ R
JP
A R
K
.r vt
/1
/2
:4
:3
A
M
AV2-108
LEVEL 1 - FLOOR PLAN - ZONE
JP
LC/JD
18051
05/01/23AV BID SET
SI
T
C C
A U
D
IO
-V
IS
U A
L R
E N
O V
A T
IO
N
SA
V
A N
N A
H , G
E O
R G
IA
A U
D
IO
V
IS
U A
L S
Y
ST
E M
F
L O
O R
P L A
N
AV BID SET
FLOOR PLAN
1/8" = 1'-0" 1
FLOOR PLAN - LEVEL 1 - ZONE 8
AUDIO VISUAL CONTRACTOR TO REMOVE EXISTING WALL
INTERFACE PLATE WITH CABLES AND INSTALL NEW FINISHED
CONNECTORIZED PLATE IN SAME LOCATION. REFERENCE PLATE
DETAILS. AUDIO VISUAL CONTRATOR TO UTILIZE EXISTING A 4-
GANG BACK BOX FOR PATHWAY ROUTE TO RACK ROOM.
WALL MOUNTED LOUDSPEAKER "S5". ELECTRICAL CONTRACTOR
TO PROVIDE AND INSTALL ONE (1) - 1-GANG WALL BOX LOCATED
AT 96-INCHES AFF. SUB-UP ONE(1) 1-INCH CONDUIT TO
ACCESSIBLE CIEILING. SEE DETAIL DRAWINGS FOR ADDITIONAL
INFORMATION.
CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT
CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE
INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE
PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND
INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-
ACCESSIBLE CEILING OR HARD CEILING AREAS.
KEY NOTES:
A. UTILIZE EXISTING CONDUIT OR PATHWAY AND RUN THROUGH
AV RACK ACCESS.
B. UTILIZE EXISTING POWER RECEPTACLE. AUDIO VISUAL
CONTRACTOR TO DETERMINE IF CIRCUIT IS DEDICATED AND IF
SECOND CIRCUIT IS REQUIRED.
GENERAL NOTES:
S4S4S4S4 S4S4
S4S4
S4S4
S4S4
S4S4
S4S4 S4S4
RESTAURANT
CAFE
MEETING ROOMS
C3.388
MEETING ROOMS
C3.389
MEETING ROOMS
C3.390
MEETING ROOMS
Administrative
Offices
RECEPTION
B.O.H.
B.O.H.
1 2
(TYP)
AV
CTL1
AV
INP2
AV
INP2
(TYP)
Z11-1.1 Z11-1.1 Z11-1.1 Z11-1.1 Z11-1.1
Z11-1.1 Z11-1.1
Z11-1.1Z11-1.1
Z11-1.1
TO AV
RACK
N
ZONE 08ZONE 13 ZONE 03
ZONE 07ZONE 12 ZONE 02
ZONE 06ZONE 11 ZONE 01
ZONE 09ZONE 14 ZONE 04
ZONE 10ZONE 15 ZONE 05
A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR
LEVEL 1
LEVEL 2 & P1
LEVEL 3 & P2
LEVEL 4 & P3
LEVEL 5 & P4
LEVEL 6 & P5
LEVEL 7
DIAGRAM SECTION CUT
AT ZONES 13, 08, 03
L O
W E
R R
O
SW
E
LL
R O
A D
, S U
IT
E
O N
E M
A R
IE
T
T A
, G E
O R
G
IA
P
H O
N E
F
A X
W
W W
.J A
E N
G
IN
E E
R
IN
G .N
E T
Professional Seal
These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018
Project No:
Drawn By:
Checked By:
Original Document Size = 36" x 48"
C
U se rs \j p a rk \D o cu m e n ts
\1
_S a va n n a h
C o n ve n ti o n _C e n te r_
E xi st in g J&
A _C e n tr a l_ R
JP
A R
K
.r vt
/1
/2
:4
:4
A
M
AV2-111
LEVEL 1 - FLOOR PLAN - ZONE
JP
LC/JD
18051
05/01/23AV BID SET
SI
T
C C
A U
D
IO
-V
IS
U A
L R
E N
O V
A T
IO
N
SA
V
A N
N A
H , G
E O
R G
IA
A U
D
IO
V
IS
U A
L S
Y
ST
E M
F
L O
O R
P L A
N
AV BID SET
FLOOR PLAN
1/8" = 1'-0" 1
FLOOR PLAN - LEVEL 1 - ZONE 11
AUDIO VSUAL CONTRACTOR TO PROVIDE AND INSTALL WALL
MOUNTED LOUDSPEAKERS.
ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ONE 1-
GANG BACK BOX FLUSH-MOUNTED IN WALL AT 120-INCHES A.F.F
TO CENTER AND ONE (1) 1-INCH CONDUIT , STUBBED UP TO
ACCESSIBLE CEILING FOR WALL LOUDSPEAKER.
CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT
CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE
INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE
PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND
INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-
ACCESSIBLE CEILING OR HARD CEILING AREAS.
AUDIO VISUAL CONTRACTOR TO REMOVE EXISTING WALL
INTERFACE PLATE WITH CABLES AND INSTALL NEW FINISHED
CONNECTORIZED PLATE IN SAME LOCATION. REFERENCE PLATE
DETAILS. AUDIO VISUAL CONTRATOR TO UTILIZE EXISTING A 4-
GANG BACK BOX FOR PATHWAY ROUTE TO RACK ROOM.
KEY NOTES:
A. UTILIZE EXISTING CONDUIT OR PATHWAY AND RUN THROUGH
AV RACK ACCESS.
B. UTILIZE EXISTING POWER RECEPTACLE. AUDIO VISUAL
CONTRACTOR TO DETERMINE IF CIRCUIT IS DEDICATED AND IF
DN
DN
PUBLIC STAIRS
#34
21301
BEER & WINE
20809
SECURED
LIQUOR
STORAGE
20808
PUBLIC STAIRS
20302
AV4-105
AV4-106
AV4-106
GEORGIA
INTERNATIONAL
GALLERY
GEORGIA
INTERNATIONAL
GALLERY
BALLROOM
BALLROOM
BALLROOM
B.O.H.
MAIN KITCHEN
KITCHEN / BOH
KITCHEN / BOH
EAST
CONCOURSE
20308
GEORGIA
INTERNATIONAL
GALLERY
B.O.H.
OGLETHORPE
AUDITORIUM
OGLETHORPE
AUDITORIUM
MEETING ROOM
MEETING ROOM
MEETING ROOM
MEETING ROOM
MEETING ROOM
MEETING ROOM
NEW CONSTRUCTION
OPEN TO
BELOW
RIVER CONCOURSE PUBLIC CORRIDOE
RIVER CONCOURSE SERVICE CORRIDOE
O P
E N
T O
B E
L O
W N
ZONE 08ZONE 13 ZONE 03
ZONE 07ZONE 12 ZONE 02
ZONE 06ZONE 11 ZONE 01
ZONE 09ZONE 14 ZONE 04
ZONE 10ZONE 15 ZONE 05
A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR
LEVEL 1
LEVEL 2 & P1
LEVEL 3 & P2
LEVEL 4 & P3
LEVEL 5 & P4
LEVEL 6 & P5
LEVEL 7
DIAGRAM SECTION CUT
AT ZONES 13, 08, 03
L O
W E
R R
O
SW
E
LL
R O
A D
, S U
IT
E
O N
E M
A R
IE
T
T A
, G E
O R
G
IA
P
H O
N E
F
A X
W
W W
.J A
E N
G
IN
E E
R
IN
G .N
E T
Professional Seal
These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018
Project No:
Drawn By:
Checked By:
Original Document Size = 36" x 48"
C
U se rs \j p a rk \D o cu m e n ts
\1
_S a va n n a h
C o n ve n ti o n _C e n te r_
E xi st in g J&
A _C e n tr a l_ R
JP
A R
K
.r vt
/1
/2
:4
:0
A
M
AV2-200
OVERALL FLOOR PLAN - LEVEL
JP
LC/JD
18051
05/01/23AV BID SET
SI
T
C C
A U
D
IO
-V
IS
U A
L R
E N
O V
A T
IO
N
SA
V
A N
N A
H , G
E O
R G
IA
A U
D
IO
V
IS
U A
L S
Y
ST
E M
F
L O
O R
P L A
N
AV BID SET
FLOOR PLAN
OVERALL FLOOR PLAN - LEVEL 2
S4S4 S4S4
S4S4
S4S4
S4S4
GEORGIA
INTERNATIONAL
GALLERY
GEORGIA
INTERNATIONAL
GALLERY
RS
RS
RS
RS
1 2
(TYP)
TO MAIN
EQUIPMENT
RACK ROOM
(TYP)
TO MAIN
EQUIPMENT
RACK ROOM
(TYP)
Z2-2.2
Z2-2.2
Z2-2.2
Z2-2.2 Z2-2.2
REFERENCE AV4-106
REFERENCE AV4-106
N
ZONE 08ZONE 13 ZONE 03
ZONE 07ZONE 12 ZONE 02
ZONE 06ZONE 11 ZONE 01
ZONE 09ZONE 14 ZONE 04
ZONE 10ZONE 15 ZONE 05
A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR
LEVEL 1
LEVEL 2 & P1
LEVEL 3 & P2
LEVEL 4 & P3
LEVEL 5 & P4
LEVEL 6 & P5
LEVEL 7
DIAGRAM SECTION CUT
AT ZONES 13, 08, 03
L O
W E
R R
O
SW
E
LL
R O
A D
, S U
IT
E
O N
E M
A R
IE
T
T A
, G E
O R
G
IA
P
H O
N E
F
A X
W
W W
.J A
E N
G
IN
E E
R
IN
G .N
E T
Professional Seal
These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018
Project No:
Drawn By:
Checked By:
Original Document Size = 36" x 48"
C
U se rs \j p a rk \D o cu m e n ts
\1
_S a va n n a h
C o n ve n ti o n _C e n te r_
E xi st in g J&
A _C e n tr a l_ R
JP
A R
K
.r vt
/1
/2
:4
:0
A
M
AV2-202
LEVEL 2 - FLOOR PLAN - ZONE
JP
LC/JD
18051
05/01/23AV BID SET
SI
T
C C
A U
D
IO
-V
IS
U A
L R
E N
O V
A T
IO
N
SA
V
A N
N A
H , G
E O
R G
IA
A U
D
IO
V
IS
U A
L S
Y
ST
E M
F
L O
O R
P L A
N
AV BID SET
FLOOR PLAN
1/8" = 1'-0" 1
FLOOR PLAN - LEVEL 2 - ZONE 2
AUDIO VSUAL CONTRACTOR TO PROVIDE AND INSTALL WALL
MOUNTED LOUDSPEAKERS.
ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ONE 1-
GANG BACK BOX FLUSH-MOUNTED IN WALL AT 120-INCHES A.F.F
TO CENTER AND ONE (1) 1-INCH CONDUIT , STUBBED UP TO
ACCESSIBLE CEILING FOR WALL LOUDSPEAKER.
CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT
CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE
INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE
PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND
INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-
ACCESSIBLE CEILING OR HARD CEILING AREAS.
KEY NOTES:
A. UTILIZE EXISTING CONDUIT OR PATHWAY AND RUN THROUGH
AV RACK ACCESS.
B. UTILIZE EXISTING POWER RECEPTACLE. AUDIO VISUAL
CONTRACTOR TO DETERMINE IF CIRCUIT IS DEDICATED AND IF
S4S4 S4S4S4S4S4S4 S4S4 S4S4 S4S4
S4S4 S4S4 S4S4 S4S4 S4S4 S4S4
S4S4
S4S4 S4S4
S4S4 S4S4
S4S4
S4S4 S4S4
S4S4
S4S4
S4S4
GEORGIA
INTERNATIONAL
GALLERY
RESTROOM- MEN
C3.406
RESTROOM-
WOMEN
RESTROOM-
WOMEN
BALLROOM
B.O.H.
1 2
(TYP.)
TO MAIN
EQUIPMENT
RACK ROOM
Z11-2.1 Z6-2.2
Z6-2.2 Z6-2.2 Z6-2.2
Z6-2.2
Z6-2.1
Z6-2.1
Z6-2.1
Z6-2.1
Z6-2.1
Z6-2.1
Z6-2.1
Z6-2.1
Z6-2.1
Z6-2.1
Z6-2.1
Z6-2.1
Z6-2.1
(TYP.)
(TYP.)
Z6-2.2
Z6-2.2
Z6-2.2
Z6-2.2
Z6-2.2
TO MAIN
EQUIPMENT
RACK ROOM
(TYP.)
TO MAIN
EQUIPMENT
RACK ROOM
(TYP.)
1 2
(TYP.)
1 2
(TYP.)
Z11-2.2
N
ZONE 08ZONE 13 ZONE 03
ZONE 07ZONE 12 ZONE 02
ZONE 06ZONE 11 ZONE 01
ZONE 09ZONE 14 ZONE 04
ZONE 10ZONE 15 ZONE 05
A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR
LEVEL 1
LEVEL 2 & P1
LEVEL 3 & P2
LEVEL 4 & P3
LEVEL 5 & P4
LEVEL 6 & P5
LEVEL 7
DIAGRAM SECTION CUT
AT ZONES 13, 08, 03
L O
W E
R R
O
SW
E
LL
R O
A D
, S U
IT
E
O N
E M
A R
IE
T
T A
, G E
O R
G
IA
P
H O
N E
F
A X
W
W W
.J A
E N
G
IN
E E
R
IN
G .N
E T
Professional Seal
These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018
Project No:
Drawn By:
Checked By:
Original Document Size = 36" x 48"
C
U se rs \j p a rk \D o cu m e n ts
\1
_S a va n n a h
C o n ve n ti o n _C e n te r_
E xi st in g J&
A _C e n tr a l_ R
JP
A R
K
.r vt
/1
/2
:4
:0
A
M
AV2-206
LEVEL 2 - FLOOR PLAN - ZONE
JP
LC/JD
18051
05/01/23AV BID SET
SI
T
C C
A U
D
IO
-V
IS
U A
L R
E N
O V
A T
IO
N
SA
V
A N
N A
H , G
E O
R G
IA
A U
D
IO
V
IS
U A
L S
Y
ST
E M
F
L O
O R
P L A
N
AV BID SET
FLOOR PLAN
1/8" = 1'-0" 1
FLOOR PLAN - LEVEL 2 - ZONE 6
AUDIO VSUAL CONTRACTOR TO PROVIDE AND INSTALL WALL
MOUNTED LOUDSPEAKERS.
ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ONE 1-
GANG BACK BOX FLUSH-MOUNTED IN WALL AT 120-INCHES A.F.F
TO CENTER AND ONE (1) 1-INCH CONDUIT , STUBBED UP TO
ACCESSIBLE CEILING FOR WALL LOUDSPEAKER.
CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT
CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE
INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE
PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND
INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-
ACCESSIBLE CEILING OR HARD CEILING AREAS.
KEY NOTES:
A. UTILIZE EXISTING CONDUIT OR PATHWAY AND RUN THROUGH
AV RACK ACCESS.
B. UTILIZE EXISTING POWER RECEPTACLE. AUDIO VISUAL
CONTRACTOR TO DETERMINE IF CIRCUIT IS DEDICATED AND IF
BALLROOM
KITCHEN / BOH
OPEN TO BELOW
AV
EX
AV
EX
N
ZONE 08ZONE 13 ZONE 03
ZONE 07ZONE 12 ZONE 02
ZONE 06ZONE 11 ZONE 01
ZONE 09ZONE 14 ZONE 04
ZONE 10ZONE 15 ZONE 05
A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR
LEVEL 1
LEVEL 2 & P1
LEVEL 3 & P2
LEVEL 4 & P3
LEVEL 5 & P4
LEVEL 6 & P5
LEVEL 7
DIAGRAM SECTION CUT
AT ZONES 13, 08, 03
L O
W E
R R
O
SW
E
LL
R O
A D
, S U
IT
E
O N
E M
A R
IE
T
T A
, G E
O R
G
IA
P
H O
N E
F
A X
W
W W
.J A
E N
G
IN
E E
R
IN
G .N
E T
Professional Seal
These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018
Project No:
Drawn By:
Checked By:
Original Document Size = 36" x 48"
C
U se rs \j p a rk \D o cu m e n ts
\1
_S a va n n a h
C o n ve n ti o n _C e n te r_
E xi st in g J&
A _C e n tr a l_ R
JP
A R
K
.r vt
/1
/2
:4
:0
A
M
AV2-207
LEVEL 2 - FLOOR PLAN - ZONE
JP
LC/JD
18051
05/01/23AV BID SET
SI
T
C C
A U
D
IO
-V
IS
U A
L R
E N
O V
A T
IO
N
SA
V
A N
N A
H , G
E O
R G
IA
A U
D
IO
V
IS
U A
L S
Y
ST
E M
F
L O
O R
P L A
N
AV BID SET
FLOOR PLAN
1/8" = 1'-0" 1
FLOOR PLAN - LEVEL 2 - ZONE 7
EXISTING AV WALL INTERFACE PLATE. AUDIO VISUAL
CONTRACTOR TO LEAVE IN EXISTING WALL INTERFACE PLATE.
KEY NOTES:
A. UTILIZE EXISTING CONDUIT OR PATHWAY AND RUN THROUGH
AV RACK ACCESS.
B. UTILIZE EXISTING POWER RECEPTACLE. AUDIO VISUAL
CONTRACTOR TO DETERMINE IF CIRCUIT IS DEDICATED AND IF
S4S4
S4S4
S4S4S4S4S4S4
S4S4S4S4
S4S4
S4S4
S4S4 S4S4S4S4
S4S4
S4S4 S4S4
S4S4 S4S4
GEORGIA
INTERNATIONAL
GALLERY
505TO MAIN
EQUIPMENT
RACK ROOM
1 2
Z11-2.1
Z11-2.1
Z11-2.1
Z11-2.1
Z11-2.1
Z11-2.1
Z11-2.1
Z11-2.1
Z11-2.1
Z11-2.1
Z11-2.2
Z11-2.2 Z11-2.2
Z11-2.2
Z11-2.2
Z11-2.2
Z11-2.2
Z11-2.2
TO MAIN
EQUIPMENT
RACK ROOM
N
ZONE 08ZONE 13 ZONE 03
ZONE 07ZONE 12 ZONE 02
ZONE 06ZONE 11 ZONE 01
ZONE 09ZONE 14 ZONE 04
ZONE 10ZONE 15 ZONE 05
A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR
LEVEL 1
LEVEL 2 & P1
LEVEL 3 & P2
LEVEL 4 & P3
LEVEL 5 & P4
LEVEL 6 & P5
LEVEL 7
DIAGRAM SECTION CUT
AT ZONES 13, 08, 03
L O
W E
R R
O
SW
E
LL
R O
A D
, S U
IT
E
O N
E M
A R
IE
T
T A
, G E
O R
G
IA
P
H O
N E
F
A X
W
W W
.J A
E N
G
IN
E E
R
IN
G .N
E T
Professional Seal
These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018
Project No:
Drawn By:
Checked By:
Original Document Size = 36" x 48"
C
U se rs \j p a rk \D o cu m e n ts
\1
_S a va n n a h
C o n ve n ti o n _C e n te r_
E xi st in g J&
A _C e n tr a l_ R
JP
A R
K
.r vt
/1
/2
:4
:1
A
M
AV2-211
LEVEL 2 - FLOOR PLAN - ZONE
JP
LC/JD
18051
05/01/23AV BID SET
SI
T
C C
A U
D
IO
-V
IS
U A
L R
E N
O V
A T
IO
N
SA
V
A N
N A
H , G
E O
R G
IA
A U
D
IO
V
IS
U A
L S
Y
ST
E M
F
L O
O R
P L A
N
AV BID SET
FLOOR PLAN
1/8" = 1'-0" 1
FLOOR PLAN - LEVEL 2 - ZONE 11
AUDIO VSUAL CONTRACTOR TO PROVIDE AND INSTALL WALL
MOUNTED LOUDSPEAKERS.
ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ONE 1-
GANG BACK BOX FLUSH-MOUNTED IN WALL AT 120-INCHES A.F.F
TO CENTER AND ONE (1) 1-INCH CONDUIT , STUBBED UP TO
ACCESSIBLE CEILING FOR WALL LOUDSPEAKER.
CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT
CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE
INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE
PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND
INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-
ACCESSIBLE CEILING OR HARD CEILING AREAS.
AUDIO VISUAL CONTRACTOR TO REMOVE EXISTING WALL
INTERFACE PLATE WITH CABLES AND INSTALL NEW FINISHED
CONNECTORIZED PLATE IN SAME LOCATION. REFERENCE PLATE
DETAILS. AUDIO VISUAL CONTRATOR TO UTILIZE EXISTING A 4-
GANG BACK BOX FOR PATHWAY ROUTE TO RACK ROOM.
KEY NOTES:
A. UTILIZE EXISTING CONDUIT OR PATHWAY AND RUN THROUGH
AV RACK ACCESS.
B. UTILIZE EXISTING POWER RECEPTACLE. AUDIO VISUAL
CONTRACTOR TO DETERMINE IF CIRCUIT IS DEDICATED AND IF
100.
CONCOURSE
CONCOURSE
PUBLIC STAIRS
CONCOURSE
MEETING ROOMS
106.
101.
PUBLIC STAIRS
B.O.H.
HALL A
C2.5
HALL B
#43
CONCOURSE
MEETING ROOMS
C3.390
MEETING ROOMS
C3.389
MEETING ROOMS
C3.388
CONCOURSE
B.O.H.
B.O.H.
B.O.H.
B.O.H.
255 LOCKER ROOM
C3.383
RESTROOM- MEN
RESTROOM-
WOMEN
B.O.H.
NEW CONSTRUCTION
N
ZONE 08ZONE 13 ZONE 03
ZONE 07ZONE 12 ZONE 02
ZONE 06ZONE 11 ZONE 01
ZONE 09ZONE 14 ZONE 04
ZONE 10ZONE 15 ZONE 05
A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR
LEVEL 1
LEVEL 2 & P1
LEVEL 3 & P2
LEVEL 4 & P3
LEVEL 5 & P4
LEVEL 6 & P5
LEVEL 7
DIAGRAM SECTION CUT
AT ZONES 13, 08, 03
L O
W E
R R
O
SW
E
LL
R O
A D
, S U
IT
E
O N
E M
A R
IE
T
T A
, G E
O R
G
IA
P
H O
N E
F
A X
W
W W
.J A
E N
G
IN
E E
R
IN
G .N
E T
Professional Seal
These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018
Project No:
Drawn By:
Checked By:
Original Document Size = 36" x 48"
C
U se rs \j p a rk \D o cu m e n ts
\1
_S a va n n a h
C o n ve n ti o n _C e n te r_
E xi st in g J&
A _C e n tr a l_ R
JP
A R
K
.r vt
/1
/2
:4
:1
A
M
AV3-100
LEVEL 1 - RCP - OVERALL
JP
LC/JD
18051
05/01/23AV BID SET
SI
T
C C
A U
D
IO
-V
IS
U A
L R
E N
O V
A T
IO
N
SA
V
A N
N A
H , G
E O
R G
IA
A U
D
IO
V
IS
U A
L S
Y
ST
E M
R
C P
AV BID SET
RCP
OVERALL RCP - LEVEL 1
S1
S1
S1
S1
S1
S1
S1
S1 S1
S1 S1
S1
S1
S1
PUBLIC STAIRS
RESTROOM- MEN
RESTROOM-
WOMEN
RESTROOM- MEN
C3.380
TYP.
TYP.
TYP.
TO MAIN
EQUIPMENT
RACK ROOM
TYP.
TO MAIN
EQUIPMENT
RACK ROOM
Z1-1.3
Z1-1.2 Z1-1.2
Z1-1.2 Z1-1.2
Z1-1.3
Z1-1.3
Z1-1.3
Z1-1.3
Z1-1.3
Z1-1.3
Z1-1.3
N
ZONE 08ZONE 13 ZONE 03
ZONE 07ZONE 12 ZONE 02
ZONE 06ZONE 11 ZONE 01
ZONE 09ZONE 14 ZONE 04
ZONE 10ZONE 15 ZONE 05
A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR
LEVEL 1
LEVEL 2 & P1
LEVEL 3 & P2
LEVEL 4 & P3
LEVEL 5 & P4
LEVEL 6 & P5
LEVEL 7
DIAGRAM SECTION CUT
AT ZONES 13, 08, 03
L O
W E
R R
O
SW
E
LL
R O
A D
, S U
IT
E
O N
E M
A R
IE
T
T A
, G E
O R
G
IA
P
H O
N E
F
A X
W
W W
.J A
E N
G
IN
E E
R
IN
G .N
E T
Professional Seal
These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018
Project No:
Drawn By:
Checked By:
Original Document Size = 36" x 48"
C
U se rs \j p a rk \D o cu m e n ts
\1
_S a va n n a h
C o n ve n ti o n _C e n te r_
E xi st in g J&
A _C e n tr a l_ R
JP
A R
K
.r vt
/1
/2
:4
:2
A
M
AV3-101
LEVEL 1 - RCP - ZONE 1
JP
LC/JD
18051
05/01/23AV BID SET
SI
T
C C
A U
D
IO
-V
IS
U A
L R
E N
O V
A T
IO
N
SA
V
A N
N A
H , G
E O
R G
IA
A U
D
IO
V
IS
U A
L S
Y
ST
E M
R
C P
AV BID SET
RCP
1/8" = 1'-0" 1
RCP - LEVEL 1 - ZONE 1
CEILING MOUNTED LOUDSPEAKER TYPE "S1". AUDIO VISUAL
INTEGRATOR TO PROVIDE AND ELECTRICAL CONTRACTOR TO
INSTALL LOUDSPEAKER BACK-CAN. INTERCONNECT
LOUDSPEAKERS WITH 1-INCH CONDUIT IF CEILING IS
INACCESSIBLE AND/OR STUB TO ACCESSIBLE CEILING IF
NECESSARY. COORDINATE EXACT LOCATION WITH ARCHITECT
AND/OR OWNER.
CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT
CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE
INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE
PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND
INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-
ACCESSIBLE CEILING OR HARD CEILING AREAS.
KEY NOTES:
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S1
S1
S1
S1
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
100.
CONCOURSE
CONCOURSE
CONCOURSE
MEETING ROOMS
106.
101.
PUBLIC STAIRS
B.O.H.
B.O.H.
B.O.H.
C4.CC
CONCOURSE
TYP.
TO MAIN
EQUIPMENT
RACK ROOM
TYP.
TYP.
TYP.
TO MAIN
EQUIPMENT
RACK ROOM
TYP.
TYP.
TO MAIN
EQUIPMENT
RACK ROOM
TYP.
TYP.
TO MAIN
EQUIPMENT
RACK ROOM
TYP.
TYP.
TO MAIN
EQUIPMENT
RACK ROOM
TYP.
TYP.
TO MAIN
EQUIPMENT
RACK ROOM
TYP.
TYP.
TO MAIN
EQUIPMENT
RACK ROOM
TYP.
TYP.
TO MAIN EQUIPMENT RACK
ROOM
Z1-1.3
Z2-1.2
Z2-1.2
Z2-1.2
Z2-1.2
Z2-1.2
Z2-1.2
Z2-1.3 Z2-1.3 Z2-1.3 Z2-1.3
Z2-1.3Z2-1.3Z2-1.3Z2-1.3
Z2-1.4 Z2-1.4 Z2-1.4 Z2-1.4
Z2-1.4Z2-1.4Z2-1.4Z2-1.4
Z2-1.2
Z2-1.5
Z2-1.5 Z2-1.5 Z2-1.5 Z2-1.5
Z2-1.5Z2-1.5Z2-1.5
Z2-1.2
Z2-1.2
Z2-1.2
Z2-1.7 Z2-1.7 Z2-1.7 Z2-1.7
Z2-1.6 Z2-1.6 Z2-1.6
Z2-1.6Z2-1.6Z2-1.6Z2-1.6
Z2-1.7 Z2-1.7 Z2-1.7 Z2-1.7
Z2-1.8 Z2-1.8 Z2-1.8 Z2-1.8
Z2-1.8Z2-1.8 Z2-1.8 Z2-1.8Z2-1.2Z1-1.2
Z1-1.2
Z2-1.2
Z1-1.2
Z1-1.2
Z2-1.2
Z2-1.9 Z2-1.9 Z2-1.9 Z2-1.9
Z2-1.9Z2-1.9Z2-1.9Z2-1.9
Z2-1.6
N
ZONE 08ZONE 13 ZONE 03
ZONE 07ZONE 12 ZONE 02
ZONE 06ZONE 11 ZONE 01
ZONE 09ZONE 14 ZONE 04
ZONE 10ZONE 15 ZONE 05
A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR
LEVEL 1
LEVEL 2 & P1
LEVEL 3 & P2
LEVEL 4 & P3
LEVEL 5 & P4
LEVEL 6 & P5
LEVEL 7
DIAGRAM SECTION CUT
AT ZONES 13, 08, 03
L O
W E
R R
O
SW
E
LL
R O
A D
, S U
IT
E
O N
E M
A R
IE
T
T A
, G E
O R
G
IA
P
H O
N E
F
A X
W
W W
.J A
E N
G
IN
E E
R
IN
G .N
E T
Professional Seal
These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018
Project No:
Drawn By:
Checked By:
Original Document Size = 36" x 48"
C
U se rs \j p a rk \D o cu m e n ts
\1
_S a va n n a h
C o n ve n ti o n _C e n te r_
E xi st in g J&
A _C e n tr a l_ R
JP
A R
K
.r vt
/1
/2
:4
:2
A
M
AV3-102
LEVEL 1 - RCP - ZONE 2
JP
LC/JD
18051
05/01/23AV BID SET
SI
T
C C
A U
D
IO
-V
IS
U A
L R
E N
O V
A T
IO
N
SA
V
A N
N A
H , G
E O
R G
IA
A U
D
IO
V
IS
U A
L S
Y
ST
E M
R
C P
AV BID SET
RCP
1/8" = 1'-0" 1
RCP - LEVEL 1 - ZONE 2
CEILING MOUNTED LOUDSPEAKER TYPE "S1". AUDIO VISUAL
INTEGRATOR TO PROVIDE AND ELECTRICAL CONTRACTOR TO
INSTALL LOUDSPEAKER BACK-CAN. INTERCONNECT
LOUDSPEAKERS WITH 1-INCH CONDUIT IF CEILING IS
INACCESSIBLE AND/OR STUB TO ACCESSIBLE CEILING IF
NECESSARY. COORDINATE EXACT LOCATION WITH ARCHITECT
AND/OR OWNER.
CEILING MOUNTED LOUDSPEAKER "S2". AUDIO VISUAL
CONTRACTOR SHALL PROVIDE AND INSTALL IN-CEILING
MOUNTED LOUDSPEAKER AT LOCATION SHOWN. CONFIRM FINAL
COLOR WITH ARCHITECT.
CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT
CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE
INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE
PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND
INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-
ACCESSIBLE CEILING OR HARD CEILING AREAS.
KEY NOTES:
S1
S1
S1 S1
CONCOURSE
RESTROOM- MEN
RESTROOM-
WOMEN
HALL A
C2.5
B.O.H.
C3.76
RESTROOM- MEN
RESTROOM-
WOMEN
STORAGE
PUBLIC STAIRS
RESTROOM- MEN
RESTROOM-
WOMEN
CONCOURSE
RIVER CONCOURSE
TO MAIN
EQUIPMENT
RACK ROOM
TYP.
TYP.
TO MAIN
EQUIPMENT
RACK ROOM
Z1-1.2
Z1-1.2
Z1-1.2
Z1-1.2
Z1-1.2
Z1-1.2
N
ZONE 08ZONE 13 ZONE 03
ZONE 07ZONE 12 ZONE 02
ZONE 06ZONE 11 ZONE 01
ZONE 09ZONE 14 ZONE 04
ZONE 10ZONE 15 ZONE 05
A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR
LEVEL 1
LEVEL 2 & P1
LEVEL 3 & P2
LEVEL 4 & P3
LEVEL 5 & P4
LEVEL 6 & P5
LEVEL 7
DIAGRAM SECTION CUT
AT ZONES 13, 08, 03
L O
W E
R R
O
SW
E
LL
R O
A D
, S U
IT
E
O N
E M
A R
IE
T
T A
, G E
O R
G
IA
P
H O
N E
F
A X
W
W W
.J A
E N
G
IN
E E
R
IN
G .N
E T
Professional Seal
These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018
Project No:
Drawn By:
Checked By:
Original Document Size = 36" x 48"
C
U se rs \j p a rk \D o cu m e n ts
\1
_S a va n n a h
C o n ve n ti o n _C e n te r_
E xi st in g J&
A _C e n tr a l_ R
JP
A R
K
.r vt
/1
/2
:4
:2
A
M
AV3-106
LEVEL 1 - RCP - ZONE 6
JP
LC/JD
18051
05/01/23AV BID SET
SI
T
C C
A U
D
IO
-V
IS
U A
L R
E N
O V
A T
IO
N
SA
V
A N
N A
H , G
E O
R G
IA
A U
D
IO
V
IS
U A
L S
Y
ST
E M
R
C P
AV BID SET
FLOOR PLAN
1/8" = 1'-0" 1
RCP - LEVEL 1 - ZONE 6
CEILING MOUNTED LOUDSPEAKER TYPE "S1". AUDIO VISUAL
INTEGRATOR TO PROVIDE AND ELECTRICAL CONTRACTOR TO
INSTALL LOUDSPEAKER BACK-CAN. INTERCONNECT
LOUDSPEAKERS WITH 1-INCH CONDUIT IF CEILING IS
INACCESSIBLE AND/OR STUB TO ACCESSIBLE CEILING IF
NECESSARY. COORDINATE EXACT LOCATION WITH ARCHITECT
AND/OR OWNER.
CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT
CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE
INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE
PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND
INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-
ACCESSIBLE CEILING OR HARD CEILING AREAS.
KEY NOTES:
S2
S2 S2
S2
S2
S2
S1
S1 S1
S1
S1 S1
S1S1
S2 S2S2 S2
CONCOURSE
LOCKER ROOM
C3.387
TYP.
TO MAIN
EQUIPMENT
RACK ROOM
TYP.
TYP.
TO MAIN
EQUIPMENT
RACK ROOM
TYP.
BOARDROOM -
JASPER
BOARDROOM-
GWINNETT
BOARDROOM-
GREENE BOARDROOM-
PULASKI
TYP.
TO MAIN
EQUIPMENT
RACK ROOM
TYP.
TYP.
TO MAIN
EQUIPMENT
RACK ROOM
TYP.
Z11-1.5 Z11-1.5
Z11-1.5Z11-1.5
Z11-1.2 Z11-1.2 Z11-1.3 Z11-1.3 Z11-1.4 Z11-1.4
Z1-1.2 Z1-1.2
Z1-1.2 Z1-1.2
Z1-1.2
Z1-1.2 Z1-1.2
Z1-1.2
TO MAIN
EQUIPMENT
RACK ROOM3
TYP.
N
ZONE 08ZONE 13 ZONE 03
ZONE 07ZONE 12 ZONE 02
ZONE 06ZONE 11 ZONE 01
ZONE 09ZONE 14 ZONE 04
ZONE 10ZONE 15 ZONE 05
A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR
LEVEL 1
LEVEL 2 & P1
LEVEL 3 & P2
LEVEL 4 & P3
LEVEL 5 & P4
LEVEL 6 & P5
LEVEL 7
DIAGRAM SECTION CUT
AT ZONES 13, 08, 03
L O
W E
R R
O
SW
E
LL
R O
A D
, S U
IT
E
O N
E M
A R
IE
T
T A
, G E
O R
G
IA
P
H O
N E
F
A X
W
W W
.J A
E N
G
IN
E E
R
IN
G .N
E T
Professional Seal
These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018
Project No:
Drawn By:
Checked By:
Original Document Size = 36" x 48"
C
U se rs \j p a rk \D o cu m e n ts
\1
_S a va n n a h
C o n ve n ti o n _C e n te r_
E xi st in g J&
A _C e n tr a l_ R
JP
A R
K
.r vt
/1
/2
:4
:2
A
M
AV3-111
LEVEL 1 - RCP - ZONE 11
JP
LC/JD
18051
05/01/23AV BID SET
SI
T
C C
A U
D
IO
-V
IS
U A
L R
E N
O V
A T
IO
N
SA
V
A N
N A
H , G
E O
R G
IA
A U
D
IO
V
IS
U A
L S
Y
ST
E M
R
C P
AV BID SET
FLOOR PLAN
1/8" = 1'-0" 1
RCP - LEVEL 1 - ZONE 11
CEILING MOUNTED LOUDSPEAKER TYPE "S1". AUDIO VISUAL
INTEGRATOR TO PROVIDE AND ELECTRICAL CONTRACTOR TO
INSTALL LOUDSPEAKER BACK-CAN. INTERCONNECT
LOUDSPEAKERS WITH 1-INCH CONDUIT IF CEILING IS
INACCESSIBLE AND/OR STUB TO ACCESSIBLE CEILING IF
NECESSARY. COORDINATE EXACT LOCATION WITH ARCHITECT
AND/OR OWNER.
CEILING MOUNTED LOUDSPEAKER "S2". AUDIO VISUAL
CONTRACTOR SHALL PROVIDE AND INSTALL IN-CEILING
MOUNTED LOUDSPEAKER AT LOCATION SHOWN. CONFIRM FINAL
COLOR WITH ARCHITECT.
CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT
CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE
INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE
PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND
INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-
ACCESSIBLE CEILING OR HARD CEILING AREAS.
KEY NOTES:
S1 S1
S1
S1S1
B.O.H.
B.O.H.
B.O.H.
B.O.H.
255 LOCKER ROOM
C3.383
LOCKER ROOM
C3.387
TYP.
TO MAIN
EQUIPMENT
RACK ROOM
TYP.
B.O.H.
B.O.H.
Z1-1.2
Z1-1.2 Z1-1.2
Z1-1.2
Z1-1.2 Z1-1.2 Z1-1.2
N
ZONE 08ZONE 13 ZONE 03
ZONE 07ZONE 12 ZONE 02
ZONE 06ZONE 11 ZONE 01
ZONE 09ZONE 14 ZONE 04
ZONE 10ZONE 15 ZONE 05
A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR
LEVEL 1
LEVEL 2 & P1
LEVEL 3 & P2
LEVEL 4 & P3
LEVEL 5 & P4
LEVEL 6 & P5
LEVEL 7
DIAGRAM SECTION CUT
AT ZONES 13, 08, 03
L O
W E
R R
O
SW
E
LL
R O
A D
, S U
IT
E
O N
E M
A R
IE
T
T A
, G E
O R
G
IA
P
H O
N E
F
A X
W
W W
.J A
E N
G
IN
E E
R
IN
G .N
E T
Professional Seal
These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018
Project No:
Drawn By:
Checked By:
Original Document Size = 36" x 48"
C
U se rs \j p a rk \D o cu m e n ts
\1
_S a va n n a h
C o n ve n ti o n _C e n te r_
E xi st in g J&
A _C e n tr a l_ R
JP
A R
K
.r vt
/1
/2
:4
:3
A
M
AV3-112
LEVEL 1 - RCP - ZONE 12
JP
LC/JD
18051
05/01/23AV BID SET
SI
T
C C
A U
D
IO
-V
IS
U A
L R
E N
O V
A T
IO
N
SA
V
A N
N A
H , G
E O
R G
IA
A U
D
IO
V
IS
U A
L S
Y
ST
E M
R
C P
AV BID SET
FLOOR PLAN
1/8" = 1'-0" 1
RCP - LEVEL 1 - ZONE 12
CEILING MOUNTED LOUDSPEAKER TYPE "S1". AUDIO VISUAL
INTEGRATOR TO PROVIDE AND ELECTRICAL CONTRACTOR TO
INSTALL LOUDSPEAKER BACK-CAN. INTERCONNECT
LOUDSPEAKERS WITH 1-INCH CONDUIT IF CEILING IS
INACCESSIBLE AND/OR STUB TO ACCESSIBLE CEILING IF
NECESSARY. COORDINATE EXACT LOCATION WITH ARCHITECT
AND/OR OWNER.
CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT
CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE
INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE
PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND
INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-
ACCESSIBLE CEILING OR HARD CEILING AREAS.
KEY NOTES:
B.O.H.
EAST
CONCOURSE
20308
GEORGIA
INTERNATIONAL
GALLERY
BALLROOM
BALLROOM
BALLROOM
GEORGIA
INTERNATIONAL
GALLERY
PARKING
20815
NEW CONSTRUCTION
N
ZONE 08ZONE 13 ZONE 03
ZONE 07ZONE 12 ZONE 02
ZONE 06ZONE 11 ZONE 01
ZONE 09ZONE 14 ZONE 04
ZONE 10ZONE 15 ZONE 05
A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR
LEVEL 1
LEVEL 2 & P1
LEVEL 3 & P2
LEVEL 4 & P3
LEVEL 5 & P4
LEVEL 6 & P5
LEVEL 7
DIAGRAM SECTION CUT
AT ZONES 13, 08, 03
L O
W E
R R
O
SW
E
LL
R O
A D
, S U
IT
E
O N
E M
A R
IE
T
T A
, G E
O R
G
IA
P
H O
N E
F
A X
W
W W
.J A
E N
G
IN
E E
R
IN
G .N
E T
Professional Seal
These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018
Project No:
Drawn By:
Checked By:
Original Document Size = 36" x 48"
C
U se rs \j p a rk \D o cu m e n ts
\1
_S a va n n a h
C o n ve n ti o n _C e n te r_
E xi st in g J&
A _C e n tr a l_ R
JP
A R
K
.r vt
/1
/2
:4
:4
A
M
AV3-200
LEVEL 2 - RCP - OVERALL
JP
LC/JD
18051
05/01/23AV BID SET
SI
T
C C
A U
D
IO
-V
IS
U A
L R
E N
O V
A T
IO
N
SA
V
A N
N A
H , G
E O
R G
IA
A U
D
IO
V
IS
U A
L S
Y
ST
E M
R
C P
AV BID SET
FLOOR PLAN
1" = 20'-0" 1
OVERALL RCP - LEVEL 2
S6
S6
S6
S6
S6
S6
S6
S6
S6
S6 S6
S6
S6
S6
S6
S6
S3
S1
S4S4
GEORGIA
INTERNATIONAL
GALLERY
TO MAIN
EQUIPMENT
RACK ROOM
TYP.
TO MAIN
EQUIPMENT
RACK ROOM
TYP.
Z2-2.5
Z7-1.1
Z2-2.5
Z2-2.2
Z1-2.5
Z1-2.5
Z1-2.5
Z1-2.5
Z1-2.5
Z1-2.5
Z1-2.5
Z1-2.5
Z1-2.5
Z1-2.5
Z1-2.5
Z1-2.5
Z1-2.4
Z1-2.4
Z1-2.4
Z1-2.4
Z1-2.4
N
ZONE 08ZONE 13 ZONE 03
ZONE 07ZONE 12 ZONE 02
ZONE 06ZONE 11 ZONE 01
ZONE 09ZONE 14 ZONE 04
ZONE 10ZONE 15 ZONE 05
A0-X00 SHEET LEVEL INDICATOR A0-0XX SHEET ZONE INDICATOR
LEVEL 1
LEVEL 2 & P1
LEVEL 3 & P2
LEVEL 4 & P3
LEVEL 5 & P4
LEVEL 6 & P5
LEVEL 7
DIAGRAM SECTION CUT
AT ZONES 13, 08, 03
L O
W E
R R
O
SW
E
LL
R O
A D
, S U
IT
E
O N
E M
A R
IE
T
T A
, G E
O R
G
IA
P
H O
N E
F
A X
W
W W
.J A
E N
G
IN
E E
R
IN
G .N
E T
Professional Seal
These drawings are the property of J&A Engineering and may not be reproduced or reused without permission of J&A Engineering, LLC 2018
Project No:
Drawn By:
Checked By:
Original Document Size = 36" x 48"
C
U se rs \j p a rk \D o cu m e n ts
\1
_S a va n n a h
C o n ve n ti o n _C e n te r_
E xi st in g J&
A _C e n tr a l_ R
JP
A R
K
.r vt
/1
/2
:4
:4
A
M
AV3-201
LEVEL 2- RCP - ZONE 1
JP
LC/JD
18051
05/01/23AV BID SET
SI
T
C C
A U
D
IO
-V
IS
U A
L R
E N
O V
A T
IO
N
SA
V
A N
N A
H , G
E O
R G
IA
A U
D
IO
V
IS
U A
L S
Y
ST
E M
R
C P
AV BID SET
FLOOR PLAN
1/8" = 1'-0" 1
RCP - LEVEL 2 - ZONE 1
CEILING MOUNTED LOUDSPEAKER TYPE "S1". AUDIO VISUAL
INTEGRATOR TO PROVIDE AND ELECTRICAL CONTRACTOR TO
INSTALL LOUDSPEAKER BACK-CAN. INTERCONNECT
LOUDSPEAKERS WITH 1-INCH CONDUIT IF CEILING IS
INACCESSIBLE AND/OR STUB TO ACCESSIBLE CEILING IF
NECESSARY. COORDINATE EXACT LOCATION WITH ARCHITECT
AND/OR OWNER.
CEILING MOUNTED PENDANT SPEAKER TYPE "S3" . ELECTRICAL
CONTACTOR SHALL PROVIDE AND INSTALL A SURFACE MOUNTED
SINGLE GANG BACK BOX CAPABLE OF SUPPORTING A 11.5
POUND PENDANT SPEAKER. COORDINATE LOUDSPAKER
LOCATION WITH LIGHT FIXTURE AND DIFFUSER LOCATIONS.
COORDINATE FINISH COLOR WITH ARCHITECT. AUDIO VISUAL
CONTRACTOR TO SUSPEND LOUDSPEAKER USING AIRCRAFT
CABLE. PAINT CABLE TO MATCH CEILING FINISH.
CEILING FLOWN LOUDSPEAKERS PROVIDED AND INSTALLED BY
AUDIO VISUAL CONTRACTOR. ALL LOUDSPEAKER FINISHES,
CABLING AND RIGGING HARDWARE SHALL BE COLORED 'WHITE'.
LOUDSPEAKER SHALL BE INSTALLED IN FULL COMPLIANCE WITH
RIGGING METHODS APPROVED BY A STRUCTURAL ENGINEER.
PROFESSIONAL RIGGING HARDWARE AND FORGED EYEBOLTS
SHALL BE UTILIZED AND SHALL BE RATED FOR FIVE TIMES THE
ACTUAL LOAD. HARDWARE AND CABLES SHALL BE PRE-
MANUFACTURED FROM ATM, POLAR FOCUS, OR OTHER RIGGING
MANUFACTURER AS APPROVED. CRIMP CONNECTIONS MADE IN
THE FIELD SHALL BE INSPECTED BY A CERTIFIED RIGGING
PROFESSIONAL. RIGGING SHALL INCLUDE CAPABILITY FOR
ADJUSTMENT OF VERTICAL LOUDSPEAKER AIMING ANGLE.
CABLE PROVIDED AND INSTALLED IN J-HOOKS ON 4-FOOT
CENTERS BY AUDIO VISUAL CONTRACTOR. CABLE TO BE
INSTALLED FREE OF SPLICES BETWEEN DEVICES AND SHALL BE
PLENUM RATED. ELECTRICAL CONTRACTOR TO PROVIDE AND
INSTALL 0.75" CONDUIT WITHIN ALL OPEN CEILING, NON-
ACCESSIBLE CEILING OR HARD CEILING AREAS.
HIGH CEILING MOUNTED LOUDSPEAKER "S6". AUDIO VISUAL
CONTRACTOR SHALL PROVIDE AND INSTALL IN-CEILING
MOUNTED LOUDSPEAKER AT LOCATION SHOWN. CONFIRM FINAL
COLOR WITH ARCHITECT.
KEY NOTES:
S1S1
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S…
This is the start of the file's text. The full file is on GovTribe.