SFLC-ESD-25_Tank_and_Void_Assessment_Form.pdf
PDF 1 MB Posted
- Attached to
- USCGC William Hart Dockside Tank Clean & Inspect
- Solicitation number
- 70Z03426QHONO1007
About this file
This document is a standardized Tank and Void Assessment Form (SFLC-ESD-25) used for inspecting and evaluating the condition of ship tanks and void compartments. The form is a two-page template designed to systematically document the physical condition and structural integrity of tank systems on vessels, with a note directing users to Form SFLC-ESD-29 for compartments other than tanks and voids.
The first page captures general inspection data including inspector and cutter identification information, tank specifications (service type, area, capacity in gallons), and detailed condition assessments across multiple categories. These categories include access conditions (manhole and tank penetration), vent overflow systems with check valve functionality, ladder presence and condition, tank level indicator status, sounding tube integrity, and cathodic protection components. The form uses a 1-6 rating scale with color-coded responses (Green 1-2 for acceptable, Yellow 3-4 for marginal, Red 5-6 for critical) to evaluate cleanliness and housekeeping, coating systems on painted surfaces, and structural issues including corrosion and pitting/grooving. Page two addresses structural integrity data, requesting estimates of linear feet and square feet requiring repair, and yes/no assessments for cracks, fractures, buckling, distortions, holes, material wastage, and weld integrity. The form includes provisions for photographs and additional comments, with instructions for combining photo documentation into the final PDF file using Adobe Acrobat.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| dockside SOW.docx | DOCX document | |
| SF1449.pdf | ||
| 154B-WPC_601_302_1_-_A.pdf | ||
| 154-WPC_506_201_1_-_A.pdf | ||
| WI1 Spec.pdf | ||
| Wage Determination Honolulu.txt | TXT text file | |
| Fixed_Price_Service_FAR_HSAR_Clauses.docx | DOCX document | |
| 154-WPC_601_302_1_-_D.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SFLC-ESD-25 TANK AND VOID ASSESSMENT
FORM
GENERAL DATA Note: Use SFLC-ESD-29 for Compartments other than Tanks & Voids.
Inspector’s Name: Organization: Contact Info:
Cutter Name: Cutter Class: Hull:
Tank: Service: Tank Area: Gallons:
Solid Balast: Access Compt: Date: Assessment Reason:
ACCESS DATA
Manhole and cover condition: Tank Penetration Condition:
VENT OVERFLOW DATA
Present: Yes No Check Valve Installed: Yes No Check Valve Operates Properly: Yes No
LADDER DATA
NR of Ladder(s) Present: Yes No Ladder Damaged: Yes No Ladder Material:
TANK LEVEL INDICATOR (TLI) DATA
TLI Present in Tank: Yes No TLI Damaged: Yes No TLI Type:
SOUNDING TUBE DATA
Sounding Tube Present in Tank: Yes No Sounding Tube Damaged: Yes No Striker Plate Damaged (>50%): Yes No
CATHODIC PROTECTION DATA
Cathodic Protection in Tank: Yes No Total Zincs: Number of Zincs > 50% Depleted:
1-6 Cleanliness & Housekeeping Clean to light layer or residue 1-2 (G) Comments:
Loose accumulation scale 3-4 (Y) Impending residue and sediments 5-6 (R)
% 1-6 Coating Systems
All Painted Surfaces 1-2 (G) Comments:
3-4 (Y) 5-6 (R)
% 1-6 Structural
Corrosion 1-2 (G) Comments:
Pitting & Grooving 1-2 (G) Comments:
Page 1 of 2 18MAR2015
SFLC-ESD-25 TANK AND VOID ASSESSMENT
SHEET
Structural Integrity Data Estimated Total Linear Feet of Structure Requiring Repair: Estimated Total Square Feet of Plating Requiring Repair:
Cracks/ Fractures Present: Yes No Buckling/Deflections/ Distortions Present: Yes No Holes Present: Yes No Material Wastage Present: Yes No All Welds Intact: Yes No Structural Evaluation Recommended: Yes No
PHOTOGRAPHS
Pictures Taken (enter quantity):
Note: To add pictures to this form, Work Station must have Adobe Acrobat (not Reader) installed.
Add all photos and photo comments to a word document and save file. Open this form and click "Combine Files". Add the document with photos you've just saved and save as a new combined .pdf files.
Additional Comments:
Page 2 of 2 18MAR2015
| Ladder Material: |
| Tank Penetration Condition: |
| RESET: |
| Inspectors Name: |
| Organization: |
| Contact Info: |
| Cutter Name: |
| Cutter Class: |
| Hull: |
| Tank: |
| Service: |
| Tank Area: |
| Gallons: |
| Solid Balast: |
| Access Compt: |
| Date: |
| Assessment Reason: |
| Manhole and cover condition: |
| Text8: |
| vent preset: Off |
| cv installed: Off |
| cv operates properly: Off |
| ladder present: Off |
| ladder damaged: Off |
| tli present: Off |
| tli damaged: Off |
| cp present: Off |
| Text2: |
| Total Zincs: |
| st present: Off |
| st damaged: Off |
| sp damaged: Off |
| Pitting Grooving_3: |
| Comments: |
| Clean to light layer or residue: |
| Comments_4: |
| Loose accumulation scale: |
| Impending residue and sediments: |
| Comments_2: |
| Comments_3: |
| 111: |
| 333: |
| 222: |
| 444: |
| 666: |
| 555: |
| 777: |
| 999: |
| 888: |
| All Painted Surfaces: |
| All Painted Surfaces_2: |
| All Painted Surfaces_3: |
| Corrosion: |
| Corrosion_2: |
| Corrosion_3: |
| Pitting Grooving: |
| Pitting Grooving_2: |
| PRINT: |
| Additional Comments: |
| Estimated Total Linear Feet of Structure Requiring Repair: |
| Estimated Total Square Feet of Plating Requiring Repair: |
| Pictures Taken enter quantity: |
| cracks: Off |
| holes: Off |
| welds: Off |
| buck: Off |
| mar: Off |
| stuc: Off |
File details come from the government source that posted it. Updated .