Septic_New_Construction_Permit_4487_Audiss_Rd_SRCDS.pdf
PDF 3 MB Posted
- Solicitation number
- 25-033
- Issued by
- Santa Rosa County, Florida
About this file
This document is a Florida Department of Environmental Protection Onsite Sewage Treatment and Disposal System Construction Permit for a new septic system at 4487 Audiss Road in Milton, Florida. The permit, issued on 2/27/2025 and valid until 8/27/2026, authorizes the installation of a new 900-gallon septic tank system with a 375 square foot drainfield for a single-family residential property. The system is designed for a 3-bedroom residence with a maximum occupancy of 6 persons, with an estimated total flow of 300 gallons per day. The permit requires maintaining all setbacks in accordance with Florida Administrative Code 62-6 and properly abandoning the existing septic tank during installation.
The property, owned by Linda Coonrod, is located on a 0.459-acre parcel in Santa Rosa County's Bagdad tax district. The site evaluation indicates the proposed system location has a benchmark at 47 inches below a reference point, with the drainfield bottom to be 77 inches below the benchmark. The permit was specified by Charles F. Oker, a Private Site Evaluator, and approved by Dana Grissom, an Environmental Supervisor from the Santa Rosa County Health Department. The documentation includes detailed site plans, soil profile information, and a boundary survey, demonstrating compliance with local and state regulations for onsite sewage treatment system installation.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DATE ISSUED: 2/27/2025 12:00:00 AM EXPIRATION DATE: 8/27/2026 12:00:00 AM
FLORIDA DEPARTMENT OF
ENVIRONMENTAL PROTECTION
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION PERMIT
PERMIT NO. 57-S2-5057639
APPLICATION #: AP4184448
DATE PAID: 02/24/2025
FEE PAID: 55
RECEIPT #: 57-PID-9225181
DOCUMENT #: PR4202110
CONSTRUCTION PERMIT FOR:
[ X ] New System [ ] Existing System [ ] Holding Tank [ ] Innovative [ ] Repair [ ] Abandonment [ ] Temporary [ ]
APPLICANT: Linda Coonrod
PROPERTY ADDRESS: 4487 Audiss Rd Milton, FL 32583
LOT: BLOCK: SUBDIVISION: Metes & Bounds
PROPERTY ID #: 15-1N-28-0000-04404-0000 (SECTION, TOWNSHIP, RANGE, PARCEL NUMBER)
(OR TAX ID NUMBER)
SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 381.0065, F.S., AND CHAPTER 62-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL
PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY.
SYSTEM DESIGN AND SPECIFICATIONS
T [900 ] GALLONS / GPD Septic Tank CAPACITY MULTI-CHAMBERED/IN-SERIES [ ]
A [ ] GALLONS / GPD N/A CAPACITY MULTI-CHAMBERED/IN-SERIES [ ]
N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK: 1250 GALLONS] K [ ] GALLONS DOSING TANK CAPACITY [ ] GALLONS @ [ ] DOSES PER 24 HRS # PUMPS [ ]
D [375 ] SQUARE FEET Drainfield SYSTEM
R [ ] SQUARE FEET N/A SYSTEM
A TYPE SYSTEM: [X] STANDARD [ ] FILLED [ ] MOUND [ ]
I CONFIGURATION: [X] TRENCH [ ] BED [ ]
N F LOCATION OF BENCHMARK: Nail in tree w/orange tape near proposed.
I ELEVATION OF PROPOSED SYSTEM SITE [47] [INCHES] [BELOW] BENCHMARK/REFERENCE POINT
E BOTTOM OF DRAINFIELD TO BE [77 ] [INCHES] [BELOW] BENCHMARK/REFERENCE POINT
L
D FILL REQUIRED: [0 ] INCHES EXCAVATION REQUIRED: [0 ] INCHES
O T H E R
The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300 gpd. Install a new 900 gal septic tank system with 375 sq ft drainfield. Maintain all setbacks in accordance with FAC 62-6. Above must be completed prior to Final Inspection & Approval. A re-inspection fee will be charged for additional inspections. Properly abandon existing septic tank at time of installation.
SPECIFICATIONS BY: Charles F Oker TITLE: Private Site Evaluator
APPROVED BY: Dana Grissom TITLE: Environmental Supervisor Santa Rosa CHD
DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 62-6, FAC Page 1 of 3
57-S2-5057639
Dana Grissom Approved
| download.pdf |
| FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION PERMIT |
| SYSTEM DESIGN AND SPECIFICATIONS |
| INSTRUCTIONS: |
File details come from the government source that posted it. Updated .