About this file

The document is a comprehensive architectural and engineering plan set for a residential structure reconstruction project at 4487 Audiss Road in Milton, Florida, prepared by Dean A. Spencer Engineering, Inc. The file includes detailed elevation drawings, floor plans, foundation details, structural specifications, and wind load calculations for a single-story residential building. The plans are dated December 2, 2024, and digitally sealed by Maxwell M. Spencer, PE, with specific focus on wind load and structural engineering requirements for the property.

The project is part of a Santa Rosa County housing reconstruction initiative, with a mandatory pre-bid meeting scheduled for April 22, 2025, at the project site. Sealed bids will be accepted through the county's procurement portal until 10:00 am on May 8, 2025, with a public bid opening via Teams. The county encourages participation from small businesses, minority/women-owned businesses, and disadvantaged business enterprises, and reserves the right to waive irregularities or reject bids. The engineering plans provide extensive technical details including wall and roof sheathing specifications, wood framing requirements, foundation details, and wind resistance mechanisms, indicating a comprehensive approach to residential reconstruction that meets local building codes and structural standards.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

December 2, 2024

Building Inspection Department

This letter references the Residential Structure located at:

4487 Audiss Road, Milton, FL

The digital signature on this page applies to all pages in this binder with the structural seal as shown at the bottom of this letter. Dean A. Spencer Engineering, Inc. is only responsible for the wind load and structure of the sealed architectural pages.

This item has been digitally signed and sealed by Maxwell M. Spencer, PE on 12/2/2024 using a Digital Signature. Printed copies of this document are not considered signed and sealed, and the signature must be verified on any electronic copies.

Sincerely, Maxwell M. Spencer

Maxwell M. Spencer, PE – FL#88877

Dean A. Spencer Engineering, Inc.

1197 Tiger Trace Blvd

Gulf Breeze, FL 32563 850.932.8730 dean.spencer.pe@gmail.com

Seal Letter 4487 Audiss

2024-12-02T14:21:42-0600
Maxwell Spencer

File details come from the government source that posted it. Updated .