SENECA SOW.pdf

PDF 2 MB Posted

Attached to
Dry-Dock (DD):USCGC SENECA REPAIR FY-22
Solicitation number
70Z080-22Q-MECP0015
Issued by

About this file

This specification outlines work items required for dry-dock repair of the USCGC SENECA in fiscal year 2022. The Coast Guard seeks a contractor to perform various tasks including hull plating inspection and repair via side scan and ultrasonic testing, underwater body preservation, appendage leak testing and preservation, shaft fairwater and rope guard inspection, void preservation and leak testing, mast preservation, and other mechanical systems work. The specification provides detailed requirements for surface preparation, coating application, inspections, record keeping, and reporting. The contractor must follow all applicable Coast Guard drawings and standards for welding, preservation, and quality control.

View the file

Other files

File Type Posted
SENECA DD FY-22 Questions Answers.pdf PDF
0002.pdf PDF
905-WMEC_123_3_1_-_B.pdf PDF
0001.pdf PDF
SENECA SOW REV-1.pdf PDF
SENECA Solicitation .pdf PDF
SENECA Schedule of Services.xls XLS spreadsheet

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

USCGC SENECA (WMEC 906)

SPECIFICATION FOR DRYDOCK REPAIRS

FY2022

Developed By: Allison J Waters

(Rev-0, 7 March 2022)

Attachment 2

USCGC SENECA (WMEC-270B) DRYDOCK AVAILABILITY FY2022

ii (Rev-0)

TABLE OF CONTENTS

Revisions Record ......................................................................................................................................... iii Consolidated List of References ................................................................................................................... iv Consolidated List of Government-furnished Property ................................................................................. ix Consolidated List of Critical Inspection Items ............................................................................................. xi Principal Characteristics ............................................................................................................................. xii General Requirements WORK ITEM 1: Hull Plating, Side Scan, Ultrasonic Testing WORK ITEM 2: Hull Plating, U/W Body, Ultrasonic Testing WORK ITEM 3: U/W Body, Preserve, 100 percent WORK ITEM 4: Hull Plating Freeboard, Preserve, 100 Percent WORK ITEM 5: Appendages (U/W), Preserve (Internal) and Leak Test WORK ITEM 6: Propulsion Shaft Fairwaters And Rope Guards, Inspect WORK ITEM 7: Voids (Non-Accessible), Preserve (Internal) and Leak Test WORK ITEM 8: Mast, Preserve, 100 Percent WORK ITEM 9: Propulsion Shafting, Strain Gage Alignment, Inspect WORK ITEM 10: Propulsion Propeller Shaft Coating, Inspect and Test WORK ITEM 11: Propulsion Shaft Seal (Mechanical And Inflatable) Assemblies, Inspect and Repair or

Renew WORK ITEM 12: Controllable Pitch Propellers, Clean and Inspect WORK ITEM 13: Controllable Pitch Propeller (CPP) System, Inspect and Service WORK ITEM 14: Controllable Pitch Propeller (CPP) Hubs, Remove, Inspect and Reinstall WORK ITEM 15: Fathometer Transducer, Renew WORK ITEM 16: Sea Strainers, Duplex, All Sizes, Overhaul WORK ITEM 17: Sea Strainers, Simplex, All Sizes, Clean and Inspect WORK ITEM 18: Rudder Assemblies, Inspect and Repair WORK ITEM 19: Superstructure, Preserve, 100 Percent WORK ITEM 20: Cathodic Protection, Zinc Anodes, Renew WORK ITEM 21: Drydock WORK ITEM 22: Temporary Services, Provide - Cutter WORK ITEM 23: Deep Water Sounder, Remove WORK ITEM 24: Doppler Speed Log, Replace WORK ITEM 25: Tank Top and Sea Chest Plating, Renew WORK ITEM 26: Hull Plating, Renew WORK ITEM 27: Bulkhead Plating, Renew WORK ITEM 28: Deck Covering, One-Step Deck, Renew WORK ITEM 29: Bilge, Auxiliary Machinery Space No 2, Preserve, 100 Percent WORK ITEM 30: Bilge, Engine Room, Partial Preserve WORK ITEM 31: Sanitary Space Deck Plating, Renew WORK ITEM 32: Bilge, JP-5 Pump Room, Preserve, 100 Percent WORK ITEM 33: Auxiliary Seawater Piping, Renew WORK ITEM 34: Bilge, Dry Stores, Partial Preserve WORK ITEM 35: Ventilation Duct, Repair WORK ITEM 36: Sea Valves and Waster Pieces, Overhaul or Renew WORK ITEM 37: Tank Bottom Plating, Renew WORK ITEM 38: Ventilation Duct, Repair WORK ITEM 39: Tanks, Ballast, Preserve, 100 Percent WORK ITEM 40: Starboard Rudder Bore, Repair WORK ITEM 41: Oily Water Separator Potable Water Supply, Modify iii (Rev-0)

REVISIONS RECORD

This page is used to record specification revisions, which may have occurred subsequent to a Revision 0 (Rev-0) package. Information listed is intended to provide contractors and field unit personnel a means to ensure all the current specification revision pages are present when reviewing or utilizing this specification package.

DATE REV# WORK

ITEM#

CHANGES MADE

NOTE: All work item and paragraph numbers listed above for a given revision correspond to same numbers in the previous revision. This revised specification is self-contained with all of the above listed changes incorporated.

iv (Rev-0)

CONSOLIDATED LIST OF REFERENCES

The below-listed documents form a part of this specification to the extent specified herein. Approval/publication dates or revision dates/numbers are also identified, to ensure that same document versions are used at the time of specification writing and during contract execution.

All Coast Guard drawings, technical publications, and standard specifications will be provided to contractors by the Coast Guard at an appropriate time, or upon request, free of charge. Other Government documents may be accessed – free of charge – from links located on the SFLC website. Commercial sites provide access to their respective documents.

COAST GUARD DRAWINGS

Coast Guard Drawing 901 WMEC 256-012, Rev -, Shaft Seal Vent Line Modification

Coast Guard Drawing 901 WMEC 320-035, Rev AR, As-Built Electrical One Line Diagram

Coast Guard Drawing 901 WMEC 320-076, Rev A, Electrical Power Sys Mods, GEA Westfalia OWS

Install

Coast Guard Drawing 901 WMEC 320-079, Rev -, OWS Booster Pump and Cooling Fan Install

Coast Guard Drawing 901 WMEC 410-009, Rev L, Seawatch Block Diagram & Installation Details

Coast Guard Drawing 901 WMEC 424-004, Rev E, Doppler Speed Log System Replacement Ripout, Installation, Arrangement, Wiring and Details

Coast Guard Drawing 901 WMEC 431-003, Rev J, Main IC Switchboard Arrangements, ELEM WRG

DIAG & DETS

Coast Guard Drawing 901 WMEC 431-004, Rev F, Replacement Main IC SWBD Ripout\Installation

Details

Coast Guard Drawing 901 WMEC 451-010, Rev D, 1SG38-SINS2(V)45 Installation BWD & Details

Coast Guard Drawing 901 WMEC 451-011, Rev B, 1SG38-SINS2(V)45 Wiring Data (COED)

Coast Guard Drawing 901 WMEC 562-005, Rev K, Rudder Stock and Steering Gear A & D

Coast Guard Drawing 901 WMEC 593-033, Rev D, Piping Mods, GEA Westfalia OWS Install

Coast Guard Drawing 905 WMEC 111-001, Rev E, Shell Expansion Fwd 101

Coast Guard Drawing 905 WMEC 111-002, Rev F, Shell Exp Aft 182

Coast Guard Drawing 905 WMEC 111-003, Rev F, Shell Exp Fr 101-182

Coast Guard Drawing 905 WMEC 113-001, Rev C, Tank Top Pl & Fr Fwd Fr 101

Coast Guard Drawing 905 WMEC 113-002, Rev A, Tank Top Pltg & Framing Aft 182

Coast Guard Drawing 905 WMEC 113-003, Rev F, Tank Top Pltg & Framing Fr 101-182

Coast Guard Drawing 905 WMEC 114-001, Rev D, Skeg

Coast Guard Drawing 905 WMEC 114-002, Rev C, Bilge Keels

Coast Guard Drawing 905 WMEC 114-003, Rev B, Shaft Fairwaters & Rope Guards

Coast Guard Drawing 905 WMEC 117-003, Rev C, FP Frwk, Breast Hook & Stem Bar Fwd Fr 28

Coast Guard Drawing 905 WMEC 122-003, Rev D, Transv Bhds 103, 117

Coast Guard Drawing 905 WMEC 123-003, Rev B, Misc Built-in Tanks & Sea Chest Struct

Coast Guard Drawing 905 WMEC 131-001, Rev D, Main Deck, Plate & Frame, Fwd 101

Coast Guard Drawing 905 WMEC 162-001, Rev B, Stacks v (Rev-0)

Coast Guard Drawing 905 WMEC 171-001, Rev F, Main Mast

Coast Guard Drawing 905 WMEC 184-010, Rev E, XDCR FDNS & Shell Mods

Coast Guard Drawing 905 WMEC 184-014, Rev B, Struct Mods Incidental to DS60 Doppler Install &

ODOM DWDS Rip-Out

Coast Guard Drawing 905 WMEC 185-009, Rev C, JP-5 Pump Room Fdns

Coast Guard Drawing 905 WMEC 201-001, Rev H, Engine Room Arrangement

Coast Guard Drawing 905 WMEC 243-001, Rev B, Shafting Arrangement

Coast Guard Drawing 905 WMEC 243-002, Rev F, Stern Tubes Strut Brg and Seal-A & D

Coast Guard Drawing 905 WMEC 243-006, Rev B, General Arrangement 12.125” Dia. Shaft Type MA

Water Lub., Inboard Stern Tube Seal

Coast Guard Drawing 905 WMEC 243-008, Rev B, Shaft & Rudder Removal Padeye A & D

Coast Guard Drawing 905 WMEC 243-010, Rev A, General Arrangement of 10.500” Dia. Bulkhead

Stuffing Box

Coast Guard Drawing 905 WMEC 243-012, Rev A, Controllable Pitch Propeller Shafting Details

Coast Guard Drawing 905 WMEC 245-001, Rev H, CPCH Prop Hyd Sys Diagram

Coast Guard Drawing 905 WMEC 245-003, Rev C, Controllable Pitch Propeller Propeller Hub Assy

Coast Guard Drawing 905 WMEC 245-004, Rev A, Controllable Pitch Propeller Blade & Palm

Coast Guard Drawing 905 WMEC 245-007, Rev C, Controllable Pitch Propeller Special Tools

Coast Guard Drawing 905 WMEC 245-008, Rev B, Controllable Pitch Propeller Actuating Unit 300.3GN

Coast Guard Drawing 905 WMEC 245-009, Rev C, CPCH Prop Hyd Sys Power Plant A & D

Coast Guard Drawing 905 WMEC 256-001, Rev W, Main & Auxiliary Salt Water Cooling System

Diagram

Coast Guard Drawing 905 WMEC 256-002, Rev J, Eng Rm SW Cooling Sys A & D

Coast Guard Drawing 905 WMEC 256-004, Rev E, AMS SW Cooling Sys A & D

Coast Guard Drawing 905 WMEC 256-011, Rev -, Mn and Aux SW Cooling Sys Diag

Coast Guard Drawing 905 WMEC 259-002, Rev C, Diesel Exhaust System Arr & Det

Coast Guard Drawing 905 WMEC 320-012, Rev F, 60 HZ Pwr Sply to ELEX Equip

Coast Guard Drawing 905 WMEC 320-013, Rev AR, Electronic Power Distribution

Coast Guard Drawing 905 WMEC 320-014, Rev AL, Electrical One Line Diagram

Coast Guard Drawing 905 WMEC 320-055, Rev A, Electrical Power Sys Mods, GEA Westfalia OWS

Install

Coast Guard Drawing 905 WMEC 321-006, Rev B, Wireways 02 LVL & Above

Coast Guard Drawing 905 WMEC 321-108, Rev-, Cable Routing

Coast Guard Drawing 905 WMEC 400-009, Rev AA, Command and Surveillance Wiring Data (COED)

VOL-5 Navigation Equipment Wiring Data

Coast Guard Drawing 905 WMEC 401-001, Rev AR, Arrangement Pilothouse & Bridge Wings

Coast Guard Drawing 905 WMEC 401-002, Rev BK, Arrangement Sensor Room & Command Support

Center

Coast Guard Drawing 905 WMEC 401-003, Rev M, Arr-Elec Eqpt Sp & Strm

Coast Guard Drawing 905 WMEC 401-005, Rev AH, Arrangement Communication Center

Coast Guard Drawing 905 WMEC 424-001, Rev K, Electronic Navigation Sys Acst Block & ISO Wrg

Diag vi (Rev-0)

Coast Guard Drawing 905 WMEC 426-002, Rev K, Doppler Speed Log Block & Isometric Wiring

Diagram

Coast Guard Drawing 905 WMEC 501-003, Rev F, Steering Gear Room Arrangement

Coast Guard Drawing 905 WMEC 501-004, Rev F, JP-5 Pump Room Arrangement

Coast Guard Drawing 905 WMEC 512-005, Rev E, Vent, Mn Dk Fwd 47 A&D

Coast Guard Drawing 905 WMEC 513-005, Rev F, Vent, ER & ECC – Plan, Sect & Elev A&D

Coast Guard Drawing 905 WMEC 514-002, Rev C, HVAC Equipment List

Coast Guard Drawing 905 WMEC 514-005, Rev C, HVAC Fan Rooms Main Deck A & D

Coast Guard Drawing 905 WMEC 514-013, Rev C, HVAC 01 Lvl Fwd Fr 82 A&D

Coast Guard Drawing 905 WMEC 521-013, Rev –, Fire Main and Sprinkler System Diagram

Coast Guard Drawing 905 WMEC 524-003, Rev C, Sea Conn, Sea Chest and Waster Piece A&D

Coast Guard Drawing 905 WMEC 528-001, Rev K, Plumbing Vents & Drains Sys Diagram

Coast Guard Drawing 905 WMEC 528-006, Rev D, Vents & Drains Main Deck A&D

Coast Guard Drawing 905 WMEC 529-006, Rev -, Ballasting & Emerg Bilge Drainage Sys Diagram

Coast Guard Drawing 905 WMEC 562-001, Rev G, Rudder

Coast Guard Drawing 905 WMEC 562-003, Rev B, GA of 11.10” Type ES Rudderstock Seal for WMEC

Coast Guard 270’ BEAR Class Cutters

Coast Guard Drawing 905 WMEC 588-003, Rev E, Hlcptr Safety Net A & D

Coast Guard Drawing 905 WMEC 593-004, Rev E, Sewage Transfer System- A&D

Coast Guard Drawing 905 WMEC 593-021, Rev C, Piping Mods, GEA Westfalia OWS Install

Coast Guard Drawing 905 WMEC 602-002, Rev C, Distinguishing Figures

Coast Guard Drawing 905 WMEC 621-003, Rev G, Joiner Arr Main Deck Frames 47-117

Coast Guard Drawing 905 WMEC 631-001, Rev L, Paint Schedule

Coast Guard Drawing 905 WMEC 633-001, Rev B, Cathodic Protection A & D

Coast Guard Drawing 905 WMEC 634-001, Rev D, Deck Covering Schedule

Coast Guard Drawing 905 WMEC 635-001, Rev F, Hull Thermal & Acoustic Insulation A/D

Coast Guard Drawing 905 WMEC 801-007, Rev E, General Arrangement Hold

Coast Guard Drawing 905 WMEC 801-009, Rev J, Outboard Profile

Coast Guard Drawing 905 WMEC 801-012, Rev C, Curves of Form

Coast Guard Drawing 905 WMEC 801-033, Rev F, Docking Plan USCGC SENECA

Coast Guard Drawing 905 WMEC 801-040, Rev G, Docking Plan

Coast Guard Drawing FL 184-002, Rev A, SS60 Transducer Install Adapter Assy

Coast Guard Drawing FL 184-003, Rev B, DS-60 Doppler Shell Ring Fabrication

Coast Guard Fleet Drawing FL 2804-12, Rev -, U.S.C.G. Emblem

Coast Guard Fleet Drawing FL 2804-22, Rev A, Consolidated Visual ID for Cutters

Naval Sea Systems Command (NAVSEA) 0944-LP-005-0010, Propeller Controller Ptch Plant

NAVSEA Drawing 803-921865, Rev R, Cathodic Protection Hull Zinc Anodes

NAVSEA Drawing 804-5773931, Rev A, Acoustic & Thermal Insulation for Compartments Installation

Details

COAST GUARD PUBLICATIONS

Coast Guard Commandant Instruction (COMDTINST) M10360.3, Jun 2006, Coatings and Colors

Manual vii (Rev-0)

Coast Guard Technical Publication (TP) 2817, SWBS 245, Section A, Feb 2018, Controllable Pitch

Propeller System

Coast Guard Technical Publication (TP) 5454, Nov 2013, Technical Manual for Type MA Mechanical

Stern Tube Seal

Coast Guard Technical Publication (TP) 9169, Aug 2018, Electro-Hydraulic Steering System & Alarm

System Upgrade, 270’ WMEC “A” and “B” Class Cutters

Coast Guard Technical Publication 10500, Mar 2021, Doppler Sonar – Model DS-60

Coast Guard Technical Publication E-424-027, 2012, SOUNDER, DEEP WATER - MODEL DF3200

Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2020, General

Requirements

Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2020, Welding and

Allied Processes

Surface Forces Logistics Center Standard Specification 0850 (SFLC Std Spec 0850), 2020, General

Requirements for Drawing Preparation

Surface Forces Logistics Center Standard Specification 3041 (SFLC Std Spec 3041), 2020, Shipboard

Electrical Cable Test

Surface Forces Logistics Center Standard Specification 3042 (SFLC Std Spec 3042), 2020, Shipboard

Electrical Cable Removal, Relocation, Splice, Repair, and Installation

Surface Forces Logistics Center Standard Specification 5000 (SFLC Std Spec 5000), 2020, Auxiliary

Machine Systems

Surface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), 2020, Requirements for Preservation of Ship Structures

Surface Forces Logistics Center Standard Specification 6341 (SFLC Std Spec 6341), 2020, Install New

Deck Covering Systems

Surface Forces Logistics Center Standard Specification 8634 (SFLC Std Spec 8634), 2020, Drydocking

Surface Forces Logistics Center Standard Specification 8635 (SFLC Std Spec 8635), 2020, Temporary

Services

Surface Forces Logistics Center Standard Specification 8636 (SFLC Std Spec 8636), 2020, Temporary

Hull Accesses

OTHER REFERENCES

American Society for Nondestructive Testing (ASNT) SNT-TC-1A, 2020, Recommended Practice for

Personal Qualification and Certification in Nondestructive Testing

American Society of Mechanical Engineers (ASME) B16.34, 2017, Valves-Flanged, Threaded, and

Welding End

ASTM International (ASTM) D1330, 2015, Standard Specification for Rubber Sheet Gaskets

ASTM International (ASTM) D5363, 2016, Standard Specification for Anaerobic Single-Component

Adhesives (AN)

ASTM International (ASTM) F683, 2014, Standard Practice for Selection and Application of Thermal

Insulation for Piping and Machinery

ASTM International (ASTM) F992, 2017, Standard Specification for Valve Label Plates

Commercial Item Description (CID) A-A-59313, Nov 2003, Thread Compound; Anti-seize, Zinc Dust-

Petrolatum

Federal Specification (Fed Spec) HH-P-151, Mar 1991, Packing; Rubber-Sheet, Cloth-Insert viii (Rev-0)

International Standard Organization (ISO) 4406, 2017, Hydraulic Fluid Power – Fluids – Method for

Coding the Level of Contamination by Solid Particles – Third Edition

Manufacturers Standardization Society of the Valve and Fittings Industry (MSS) SP-61, 2013 Edition, Pressure Testing Of Steel Valves

Manufacturers Standardization Society of the Valve and Fittings Industry (MSS) SP-67, 2017 Edition, Butterfly Valves

Manufacturers Standardization Society of the Valve and Fittings Industry (MSS) SP-72, 2018 Edition, Ball Valves with Flanged or Butt-Welding Ends for General Service

Manufacturers' Standardization Society of the Valve and Fittings Industry (MSS) SP-80, 2013 Edition, Bronze Gate, Globe, Angle and Check Valves

Manufacturers Standardization Society of the Valve and Fittings Industry (MSS), SP-58, 2018, Pipe

Hangers and Supports – Materials, Design, Manufacture, Selection, Application and Installation

MIL-A-18001, Dec 2015, Anodes, Sacrificial Zinc Alloy

MIL-PRF-16173E, Oct 2017, Corrosion Prevention Compound, Solvent Cutback, Cold-Application

MIL-PRF-17672E, Oct 2012, Hydraulic Fluid, Petroleum, Inhibited

MIL-S-45180, 1998, Sealing Compound, Gasket, Hydrocarbon Fluid and Water Resistant

MIL-STD-2199B (SH), Jan 2020, Coverings for Waterborne Main Propulsion Shafting on U.S. Naval

Surface Ships and Submarines

NAVSEA Technical Publication T9074-AD-GIB-010/1688, (TP 1688), May 1997, Requirements for

Fabrication, Welding, and Inspection of Submarine Structure

Society of Automotive Engineers (SAE) Aerospace Material Specification (AMS) G-6032, 2020, Grease, Plug Valve, Gasoline and Oil Resistant, NATO Code Number G-363, Metric

The Society for Protective Coatings (SSPC) Surface Preparation Specification No.1 (SSPC-SP 1), 2016, Solvent Cleaning

The Society for Protective Coatings (SSPC)/NACE International (NACE) Joint Surface Preparation

Standard SSPC-SP 10/NACE No.2, 2007, Near-White Blast Cleaning

The Society for Protective Coatings (SSPC)/NACE International (NACE) Joint Surface Preparation

Standard SSPC-SP WJ-2, 2012, Waterjet Cleaning of Metals – Very Thorough Cleaning ix (Rev-0)

CONSOLIDATED LIST OF GOVERNMENT-FURNISHED PROPERTY

The following is a list of property, which the Government will furnish. This list supersedes any other material obligations indicated or implied by referenced drawings.

WORK

ITEM

MTI ITEM DESCRIPTION NSN/PN QTY ESTIMATED

COST

($/UNIT)

11 N Stern tube seal major overhaul kit

NSN: 5330-01-527-0959 2 ea. 34,607.00

11 N **Stern tube seal split seat

NSN: 5330-01-359-5555 2 ea. 12,708.00

11 N **Stern tube seal face change out kit

NSN: 5330-01-527-0696 2 kt. 8,954.00

11 N Automatic Air Eliminator PN: AE36 NSN: 4820-01-690-

2 ea. 543.00

13 N O.D. Box Inspection Kit NSN: 3010-01470-3519 2 kt. 1,173.00

13 N Filter NSN: 4330-01-177-4069 12 ea. 97.00

13 Y **Oil Feed Bushing NSN: 3120-12-329-5287 2 ea. 14,800.00

13 N **Ball Bearing NSN: 3110-00-156-6745 2 pr. 120.00

13 N **Bearing Bushing NSN: 2010-01-469-8639 2 ea. 1,300.00

13 N **Bearing Bushing NSN: 3120-12-198-7607 8 ea. 1,300.00

13 N **Spool valve assembly NSN: 4820-01-513-2509 2 ay. 30,000.00

14 N Hub Installation kit NSN: 2010-01-470-3258 2 kt. 215.00

14 Y **Left hand hub assembly

NSN: 2010-01-119-5469 1 ea. 304,313.00

14 Y **Right hand hub assembly

NSN: 2010-01-118-8538 1 ea. 304,313.00

14 N ***CPP Tool Kit N/A 1 se. 20,000.00

14 N *"Special tools" (see 4.2

(Government-loaned installation tools))

N/A 1 se. 1,000.00

14 Y **Propeller Blade-RH

(Port)

NSN: 2010-01-119-3972 1 se. 40,000.00

14 Y **Propeller Blade-LH

(Stbd)

NSN: 2010-01-120-2871 1 se. 40,000.00

14 N O-Ring NSN: 5330-01-120-5229 8 ea. 97.00

14 N O-Ring NSN: 5330-01-118-8529 8 ea. 96.00

14 N Blade Washer NSN: 5310-01-335-4361 48 ea. 112.00

14 Y **Shoulder bolt NSN: 5306-01-118-8337 8 ea. 1,897.00

14 Y **Shoulder blade bolt NSN: 5306-01-119-3607 16 ea. 857.00

15 Y ***Fathometer

Transducer, Shallow

Water

NSN: 5845-01-668-2181 PN:

A80214

1 ea. 1,884.26

18 N John Crane Seal kit NSN: 5330-01-527-0778 2 ea. 5,955.00

18 Y **Rudder Assembly NSN: 2040-01-486-0550 2 ea. 182,000.00

18 N **Upper Bearing NSN: 3110-01-121-8032 2 ea. 3,910.00

18 N **Thordon Lower

Bearing (SXL 20.7" X

17.5" X 14)

PN: F546150102 2 ea. 1,000.00

21 Y *Transducer Cover Plate N/A 4 ea. 50.00

24 N Display Unit, DS60 PN: DS600 1 ea. 1,200.00 x (Rev-0)

24 N Distribution Unit, DS60 PN: DS610 1 ea. 1,200.00

24 N Transceiver Unit, DS60 PN: DS620 1.ea. 800.00

24 N Transducer w/30M Cable PN: DS630-30 1 ea. 200.00

24 N Gate Valve, DS60 PN: DS661 1 ea. 300.00

24 N Hull ring PN: DS-661-1 1 ea. 350.00

24 N Hanger Bracket PN: 000-016-313 1 ea 262.50

24 N Remote Display RD-33 PN: 7025-01-616-1486 1 ea 671.98

24 N Cable Assembly, Can, Bus, (included with RD-

PN: M12-05BM+05BF-06 1 ea 0.00

41 N Booster Pump Control

Panel

PN: BCP11-0.5-D-L1-E2-POL-

PRL-DSP NSN: 6110-01-f20-

1 ea. 2950.00

41 N Potable Water Booster

Pump

PN: Grundfos Model CR 1-4-1-

FGJ-I-E-HQQE-60 HZ NSN:

4320-01-689-8635

1 ea. 950.00

41 N Thermal Transfer System PN: AOC-08-41-1PH NSN:

4420-01-F21-6424

1ea. 437.00

*Government-loaned property, which shall be returned to the vessel upon completion of the availability.

**New or refurbished equipment that the Government may provide for installation in place of existing equipment.

***Government-furnished property, which is to be supplied by either the vessel or the C4IT ServiceCenter xi (Rev-0)

CONSOLIDATED LIST OF CRITICAL INSPECTION ITEMS

The following is a list of work items, which contain Critical Inspection reports, which the Contractor must complete within the first 25% of the availability contract period (see SFLC Std Spec 0000, paragraph 3.2.6.1.4

(Inspection report particulars)):

Work

Item Title

1 Hull Plating, Side Scan, Ultrasonic Testing

2 Hull Plating, U/W Body, Ultrasonic Testing

3 U/W Body, Preserve, 100 percent

5 Appendages (U/W), Preserve (Internal) and Leak Test

7 Voids (Non-Accessible), Preserve (Internal) and Leak Test

10 Propulsion Propeller Shaft Coating, Inspect and Test

Propulsion Shaft Seal (Mechanical And Inflatable) Assemblies, Inspect and Repair or

Renew

12 Controllable Pitch Propellers, Clean and Inspect

13 Controllable Pitch Propeller (CPP) System, Inspect and Service

14 Controllable Pitch Propeller (CPP) Hubs, Remove, Inspect and Reinstall

16 Sea Strainers, Duplex, All Sizes, Overhaul

17 Sea Strainers, Simplex, All Sizes, Clean and Inspect

18 Rudder Assemblies, Inspect and Repair xii (Rev-0)

PRINCIPAL CHARACTERISTICS

270' WMEC (B-CLASS)

PHYSICAL

Length overall 270' 0"

Length between perpendiculars 255' 0"

Beam molded 38' 0"

Depth molded, main deck amidships, 01 level amidships

23' 7"

31' 4"

Full load displacement 1,886 long tons

Draft, full load to baseline amidships 14' 2"

Highest projection above baseline

*height approximated

≈ 110' 0"

Shore tie voltage requirements 2 cables, 400A / 450V, 3 phase

Frame spacing 1' 0"

MACHINERY

Main propulsion 2 ALCO Model 18-251-F Diesel Engines, 3,650 BHP each

Ship’s service generators 2 Caterpillar Model D-398-TA Diesel-driven KATO 6P6-1350 Generators. 475

KW each @ 0.8 power factor, 450VAC, 3 phase, 60 cycle

Emergency generators Caterpillar Model D-348-TA Diesel-driven KATO 4P4-1900. 475KW @ 0.8 power factor, 450VAC, 3 phase, 60 cycle

Number of propellers 2

Propeller diameter 9' 0"

Number of blades, each 4

Pitch Controllable

Shaft RPM 260

Shaft diameter 10.55" at exit of hull

Anchor & chain Two 4,000 lb Navy Stockless Anchors, 8 shots of chain each

TANK CAPACITIES

Diesel fuel total (95%) 79,950 gal.

JP-5 total (95%) 19,626 gal.

Potable water total (100%) 8,553 gal.

Hydraulic & lube oil total (95%) 2,561 gal.

1 (Rev-0)

00000_0222_FLT

REC_00000_FLT_Commercial Project @ CG Facility (0121)

General Requirements

1. SCOPE

1.1 Intent. This standard specification invokes general requirements for conducting vessel repairs performed by commercial contractors at a Coast Guard facility for Coast Guard vessels.

1.2 Term interchangeability. The terms 'Contractor', 'CG Yard', 'NAVSTA EVERETT', 'shipyard', 'Base', and

'Coast Guard Industrial' are used interchangeably in this specification. Where the primary service provider is

Coast Guard personnel, references to contractor and other noted descriptors within this specification or within drawings, publications, SFLC Standard Specifications or other commercial and military references are deemed the same as prime service provider.

2. REFERENCES

COAST GUARD DRAWINGS

None

COAST GUARD PUBLICATIONS

Coast Guard Commandant Instruction (COMDTINST) M10360.3 (series), Coatings and Color Manual

Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2020, General

Requirements

Surface Forces Logistics Center Standard Specification 0740 (SFLC Std Spec 0740), 2020, Welding and

Allied Processes

Surface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), 2020, Requirements for Preservation of Ship Structures

OTHER REFERENCES

NAVSEA Technical Publication T9074-AD-GIB-010/1688, (TP 1688), May 1997, Requirements for

Fabrication, Welding, and Inspection of Submarine Structure

3. REQUIREMENTS

3.1 General. The Contractor must conform to all requirements specified in SFLC Std Spec 0000 and in this item, as applicable, during the performance of this availability. The requirements of this WI applies to all work under the scope of this contract, whether explicitly stated in all following work items or not, and to all other work subsequently authorized by changes, modifications, or extensions to the contract.

2 (Rev-0)

3.1.1 NAVSEA drawings listed will be available FOR INSPECTION ONLY from the Coast Guard Port Engineer post-award. SFLC will not redistribute NAVSEA documents. Contractors can apply to NAVSEA headquarters directly for copies.

3.2 Fire watch requirements. The Contractor must refer to 3.3.1.3 (Fire watch requirements) of SFLC Std Spec

0000, in accomplishing the following task:

Provide portable fire extinguishers for Coast Guard fire watch personnel. Coast Guard fire watch is in lieu of contractor personnel during the hours of 0800-1600, Monday through Friday, and limited to two Coast Guard fire watch personnel.

Provide fire watch personnel and fire extinguishers for the duration of the availability period, during and beyond noted Coast Guard fire watch support.

3.3 Preservation requirements. The Contractor must accomplish all preservation tasks, including touch-ups, in accordance with SFLC Std Spec 6310.

3.3.1 Brand name approval. Ensure that all contractor-furnished coatings are in accordance with SFLC Std Spec

6310, Appendix C (Authorized Coatings for Use on Cutters and Boats).

3.3.2 Coating colors and system color schemes. The Contractor must obtain a written KO authorization to deviate from any coatings required in SFLC Std Spec 6310 Appendix C before work.

3.3.3 In-process quality control measures. The Contractor must abide by all the safety, preservation, and quality control requirements specified in SFLC Std Spec 0000, paragraph 3.2.4.2 (In-process QC measures for “critical-coated surfaces”).

3.3.3.1 Quality control requirements. The Contractor must abide by the following when performing preservation related inspections. The following measurements must be randomly spaced throughout for the purposes of providing a representation of the entire prepared or coated surface.

3.3.3.1.1 Surface profile measurements. One surface profile measurement must be taken for every 200 square feet for the first 1000 square feet; for each additional 500 square feet or less, one profile measurement must be taken.

Profile measurements must be taken in accordance with SFLC Std Spec 6310, paragraph 3.1.8.3 (Surface profile measurements). A “measurement” for surface profile is defined as follows:

ASTM D4417, Method B: One profile measurement is the average (mean) of 10 individual readings.

ASTM D4417, Method C: One profile measurement is the average (mean) of 2 individual readings.

3.3.3.1.2 Soluble salt conductivity measurements. 5 conductivity measurements must be taken every 1000 square feet. For submerged (immersed) applications conductivity measurements must not exceed 30 microsiemens/cm.

For non-submerged (non-immersed) applications conductivity measurements must not exceed 70 microsiemens/cm. If a conductivity check fails, clean the surface in accordance with SFLC Std Spec 6310, paragraph 3.1.8.5 (Soluble salt removal).

3.3.3.1.3 Coating thickness measurements. Three area measurements must be taken for the first 1000 square feet;

for each additional 1000 square feet, perform an additional area measurement. A “measurements” for coating thickness is defined as follows:

SSPC-PA 2 defines an area measurement as 5 separate spot measurements randomly spaced throughout a 100 square foot area.

SSPC-PA 2 defines a spot measurement as 3 gage readings and each new gage reading the probe must be moved to a new location within a 1.5 inch diameter circle defining the spot.

3 (Rev-0)

3.4 Welding and brazing requirements. The Contractor must perform all welding and allied processes, and NDE in accordance with SFLC Std Spec 0740.

3.4.1 HY-130 material substitution. The Contractor must be aware that HY-130 steel plating is no longer commercially available. For the purpose of performing flight deck repairs on US Coast Guard WMEC-270 “B-

Class” cutters, Weldox 900 steel plating has been approved as a replacement for HY-130. Due to the similarity in material properties and weldability of HY-130 and Weldox 900, all welding procedures and welder qualifications for welding Weldox 900 must be the same as those outlined in NAVSEA TP 1688 as applicable for welding HY-

130.

3.4.2 Standard spec modification. For any welding involving HY-130 on the flight deck of WMEC-270 “B-Class” cutters, perform all welding and allied processes, and non-destructive evaluation (NDE) in accordance with

NAVSEA TP 1688. The Contractor must be aware that the welding requirements specified in this document take precedence over paragraph 3.3.6 of SFLC Standard Spec 0000 for the purpose of welding involving HY-130.

3.4.3 Approval to weld HY-130. To obtain Coast Guard approval to weld on HY-130 steel for WMEC-270 “B-

Class” cutters, the Contractor must provide written Performance Qualification Records (PQR’s) for each process to be used. The PQR’s must be approved by one of the regulatory agencies affirming that the WPS meets the welding requirements of NAVSEA TP 1688. In addition, the Contractor must ensure that all subcontractors, prior to performing welding operations, have qualified procedures by meeting all the requirements set forth in this document.

NOTE

NAVSEA approval is NOT required for welding procedures submitted but the procedures must be reviewed and shown to satisfy the requirements set forth in

NAVSEA TP 1688, by a welding regulatory agency. The requirements for welding

Weldox 900 must be considered the same as those for welding HY-130.

3.5 Environmental protection requirements. The Contractor must adhere to the following environmental protection requirements in accordance with the SFLC Stand Spec 0000:

3.5.1 Contractor operated (non USCG) facilities. The Contractor must provide and maintain environmental protection as defined in SFLC Std Spec 0000 Appendix A, Requirements for Environmental Protection at

Contractor Operated (Non USCG) Facilities, as applicable, during the performance of this availability. Contractor must plan for and provide environmental protective measures to control pollution that develops during normal practice, as well as plan for and provide environmental protective measures required to correct conditions that develop during the project. Contractor must comply with applicable Federal, state, and local laws, codes, ordinances, and regulations in their entirety. Any reference to a specific portion of a Federal, state, or local law, code, ordinance, or regulation in this or any other item must not be construed to mean that relief is provided from any other sections of the law, code, ordinance, or regulation.

3.5.2 Test and procedures. The Contractor is required to promptly conduct tests and procedures for the purpose of assessing whether operations are in compliance with applicable Environmental Laws. Analytical work must be done by qualified laboratories; and where required by law, the laboratories must be certified.

3.5.3 Regulatory notifications. The Contractor is responsible for all regulatory notification requirements in accordance with Federal, State and local regulations. In cases where the Coast Guard must also provide public notification, such as storm water permitting, the Contractor must coordinate with the Contracting Officer or COR, and if work is being performed at a USCG Facility, the local Facility Engineer or Engineering Officer. The

Contractor must submit copies of all regulatory notifications to the Contracting Officer and the local Facility

Engineer or Engineering Officer prior to commencement of work activities. Regulatory notifications must be

4 (Rev-0) provided for including but not limited to demolition, renovation, National Pollutant Discharge Elimination System

(NPDES) defined site work, and remediation of controlled substances such as asbestos, hazardous waste, and lead paint.

3.5.4 Environmental manager. The Contractor must appoint in writing an Environmental Manager for the project, who is responsible for coordinating Contractor compliance with Federal, State, local, and station environmental requirements. The Environmental Manager must ensure compliance with Hazardous Waste Program requirements, including hazardous waste handling, storage, manifesting, and disposal; implement the Contractors’

Environmental Management Plan; ensure that all environmental permits are obtained, maintained, and closed out;

ensure compliance with Storm Water Program Management requirements; ensure compliance with Hazardous

Materials including storage, handling, and reporting requirements; as well as coordinate any remediation of regulated substances such as lead, asbestos, and polychlorinated biphenyl (PCB). This may be a collateral position; however the individual must be trained to accomplish the following duties; ensure waste segregation and storage compatibility requirements are met; inspect and manage Satellite Accumulation areas; ensure only authorized personnel add wastes to containers; ensure all Contractor personnel are trained in 40 CFR requirements and individual position requirements; coordinate removal of waste containers; and maintain the Environmental

Records binder and required documentation, including environmental permits compliance and close-out.

3.5.5 HW disposal. Contractor must comply with SFLC Std Spec 0000 Appendix A, Requirements For

Environmental Protection At Contractor Operated (Non USCG) Facilities for HW disposal.

3.6 Local Policy. The Contractor must refer to site (e.g. Base) Regulations and Instructions for details regarding local policies (e.g. crane services, parking, or facility usage).

3.7 SFLC Standard Specification approved changes. The Contractor must be aware that the following are approved changes to published SFLC 2020 Edition Standard Specifications and supersede published content:

3.7.1 SFLC Standard Specification 8636. Add missing paragraphs between 3.2 and 3.5 of Std Spec 8636 as follows:

“3.3 Access cut boundaries. The Contractor shall ensure that access cuts comply with the requirements and restrictions detailed in the following and in SFLC Std Spec 0740, and referenced codes.

3.3.1 Location of boundaries. Boundaries of access cuts and closure plates shall, in general, be located between principal ship framing, bulkheads, and other structural members and shall be at least three inches from any of these members or from the toes of other welds. A reduction in this three inch minimum may be approved by the

KO on a case by case basis provided sufficient clearance is maintained for welding and inspection requirements.

The boundaries of access cuts and closure plates should land on existing butts or seams, wherever practicable. The boundaries of prior access cuts should be utilized wherever possible. Boundaries may extend across one or more frames as required for the size of the opening.

3.3.2 Access hole dimensions and arrangements. Holes or access cuts shall be the minimum size necessary and shall be in accordance with the following:

Rectangular access cuts and closure plates welded into primary hull structure shall be at least 12 inches wide in the lesser dimension.

For circular access cuts, the minimum diameter shall be 4T, where T = thickness of the involved structural member, but not less than three inches.

Circular closure plates for access cuts less than two feet in diameter shall be dished 1/16 to 1/8 inch to allow for shrinkage when welded.

Corners of rectangular access cuts and closure plates shall have a minimum radius of 6 inches except when a boundary lands on an existing hull longitudinal seam or transverse butt weld.

5 (Rev-0)

Corners at an existing seam or butt shall intersect at a 90 degree angle.

Cuts that are to cross existing butts or seams shall do so at an angle of 90 degrees plus or minus 15 degrees.

In primary hull structure, existing welds forming the boundary of a cut shall be cut back 3 inches beyond the toe of the access cut, except that the cut back shall not intersect or cross an existing weld, frame, or structural member. In which case, the cut back may be reduced to a minimum of two inches in length.

Existing welds crossed by the cut shall not be cut back.

3.3.3 Primary hull structure. Primary Hull Structure includes the shell, main strength decks, principal longitudinal bulkheads, vertical keel, deep web girders and stiffeners designed to withstand the ship bending stress.

3.3.4 Mechanically fastened joints. Welding closer than six inches to a mechanically fastened joint should be avoided. When access cuts cross or come within six inches of a mechanically fastened joint, the fasteners shall be checked for tightness and if necessary, loose fasteners shall be seal welded or removed, and replaced for a distance of 6 inches beyond the edge of the cut. When a cut crosses a mechanically fastened seam the cut plates shall be repaired using single V welds backed with glass tape (MIL-C-20079) to prevent fusion between the mechanically fastened plates.

3.4 Ship integrity maintenance. The Contractor shall maintain safety and ship integrity by installing temporary guarding and coaming, in addition to weathertight and watertight closures. Remove these temporary fabrications after closing the hull access, and grind surfaces flush in way of removals. For shell plating cuts made at or below the waterline where temporary closures are impractical, the Contractor shall secure each vulnerable compartment and subdivision to minimize potential damage to the extent permitted by the scope and urgency of the work.

3.4.1 Guarding. Install temporary guards in accordance with 29 CFR 1915.73.

3.4.2 Coaming. Ensure that in areas where flammable liquids may be stored, a 4 inch high metal coaming shall be installed on the surface of the deck with tack welds and fully sealed with caulking compound. The coaming shall encircle the access cut in the deck.

3.4.3 Weathertight and contamination closures. Fabricate temporary closures, using fire retardant material, before cutting access openings and install closures whenever access is not in use. Closures shall be:

Constructed to protect the access from inclement weather and entry of contaminants (shall include a coaming or dam on the deck to redirect rain runoff away from the opening).

Fitted with fasteners that permit rapid installation and removal.

Able to support a minimum of 150 pounds per square foot for horizontal deck closures.

Where the access opening is in way of a removed hatch, scuttle or door, the closure shall be configured to allow normal passage of ship’s personnel and equipment.

3.4.4 Watertight closures. Ensure that access openings created four feet or less above the maximum anticipated waterline shall include temporary watertight closures when the vessel is waterborne.

NOTE

NAVSEA S0600-AA-PRO-160/CH16 provides requirements for design, fabrication, and installation of temporary watertight closures.”

6 (Rev-0)

4. NOTES

4.1 QA inspection forms. QA inspection forms (QA-1 thru QA-5), required in SFLC Std Spec 6310 to be completed and submitted during preservation of “critical-coated surfaces”, are provided at the end of this document.

7 (Rev-0)

QA-1 - QUALITY ASSURANCE INSPECTION FORM

(PRESERVATION CHECKLIST)

VESSEL NAME HULL # WORK ITEM

WORK ITEM TITLE

LOCATION OF WORK (INCL. FRAME #’S) AREA (SQFT)

CHECKPOINT 1 – COATING SYSTEM COMPLIANCE

Ensure all coatings are in compliance with SFLC Std Spec 6310, Appendix C.

CHECKPOINT 2 - PAINT STORAGE

Ensure all coatings are kept at a temperature of 65 to 85°F at all times, unless otherwise specified by the coating mfg.

CHECKPOINT 3 - AMBIENT CONDITIONS

Ensure surface and surrounding temperatures are each between 50 and 90°F for water-containing coatings, and 35 and 95°F for other coatings, unless otherwise specified by the coating manufacturer(s).

Ensure maximum relative humidity (RH) is as follows, from surface preparations through final curing of topcoat: 50% for tanks, voids, and vent plenum; and 85% for all other areas, unless otherwise specified by manufacturer(s).

Ensure surface temperature is at least 5°F above the dew point, unless otherwise specified by the coating mfg.

CHECKPOINT 4 - PRE-SURFACE PREPARATION

Remove surface contaminants (soluble salts, loose rust, mud, and marine growth) with low pressure fresh water wash down (maximum 5,000 psi). If oil and grease are present, perform solvent cleaning, as per SSPC SP-1.

Verify equipment setup, blast media, and surface preparation methods match designated test coupon.

CHECKPOINT 5 - SURFACE PREPARATION

Verify environmental conditions (see CHECKPOINT 3).

Ensure cleanliness of prepared surface is as per specification (i.e.: SSPC SP-11, SP-10, SP WJ-2…).

Verify surface anchor profile using ASTM D4417-Methods B or C against SFLC Std Spec 6310. Conduct profile readings at a minimum of 5 locations for the first 1000-sqft area, and 2 locations for each succeeding 1000-sqft area.

Measure soluble salt conductivity in accordance with SSPC-Guide 15. Conduct 5 measurements per each 1000-sqft area (max. threshold: 70 microsiemens/cm for non-submerged surfaces, 30 microsiemens/cm for submerged surfaces).

CHECKPOINT 6 - PRIMER COAT APPLICATION

Verify environmental conditions (see CHECKPOINT 3).

Verify proper mixing and stand-in (induction) times.

Ensure no paint is applied when the temperature is expected to drop to freezing before the paint has dried.

Ensure surfaces are completely dry, unless otherwise allowed by the coating manufacturer(s).

Verify wet film thickness (WFT) at random, to prevent under or over application. Verify final DFT.

Brush out all runs, sags, drips, and puddles.

Perform visual inspection for holidays and other defects.

CHECKPOINT 7 – STRIPE COAT APPLICATION

Verify environmental conditions (see CHECKPOINT 3).

Ensure overcoating window is as per manufacturer’s instructions.

After primer coat (mist coat after inorganic zinc), brush-apply un-thinned coat of same primer paint over edges, weld seams, cut-outs, and areas of complex geometries @ 3-4 mils wet film thickness (WFT).

CHECKPOINT 8 – TOP COAT APPLICATION

Verify environmental conditions (see CHECKPOINT 3).

Ensure overcoating window is as per manufacturer’s instructions.

Verify proper mixing and stand-in (induction) times, as applicable.

Verify wet film thickness at random, to prevent under or over application.

Brush out all runs, sags, drips, and puddles.

CHECKPOINT 9 – FINAL INSPECTION

Verify final system dry film thickness. Conduct 5 sets of 3 readings for each of the first 3 100-sqft areas, followed by 5 sets of 3 readings for each succeeding 1000-sqft area.

Ensure that system cure is in accordance with manufacturer's recommendation for intended service.

Ensure potable water tank exhaust ventilation is maintained continuously from and during coating application through final system cure, to exhaust all solvent to the atmosphere and to prevent solvent entrapment.

For immersion coatings (including tank U/W body), record date and time of the following events:

Final coat application: _____/_____; Return to service or removal from environment controls: _____/_____

CHECKPOINT 10 – RECORD KEEPING

Complete, sign, and submit all provided QA Inspection Forms.

NAME OF QP-1/NACE INSPECTOR SIGNATURE CERT. # DATE / TIME

NAME OF CG REPRESENTATIVE SIGNATURE UNIT DATE/TIME

8 (Rev-0)

QA-2 - QUALITY ASSURANCE INSPECTION FORM

(ENVIRONMENTAL READINGS)

VESSEL NAME HULL #

WORK ITEM

Use one sheet for each activity. Record conditions every four hours from before surface preparation to application of final coating system coat.

DATE

TIME

ACTIVITY (SURFACE

PREPARATION, PRIMER COAT,

BARRIER COAT, TOP COAT,

ETC…)

LOCATION (FRAME &

DECK, RELATION TO

EQUIPMENT, ETC.)

TEMPERATURE % REL.

HUMID-

ITY

DEW

PT.

SURFACE AMBIENT ΔT

| DP -

SURFACE |

9 (Rev-0)

QA-3a - QUALITY ASSURANCE INSPECTION FORM

(SURFACE PROFILE LOG FOR PROFILE MEASUREMENTS IAW ASTM D4417-METHOD-C)

VESSEL NAME HULL # WORK ITEM

LOCATION OF WORK (FRAME REFERENCES) AREA (SQFT)

SURFACE PREPARATION METHOD PROFILE ACHIEVED (MILS)

MIN MAX MEAN

SSPC-SP-10/NACE No. 2

SSPC-SP WJ-2/NACE WJ-2

SSPC-SP-3

SSPC-SP-11

SSPC-SP-11 (inaccessible area)

Brush-blasting (non-metallic substrate)

ABRASIVE MANUFACTURER: ABRASIVE SIEVE SIZE:

PLACE SURFACE PROFILE REPLICA TAPES IN THE SPACES PROVIDED BELOW, TO SERVE AS

PERMANENT QA RECORD. MAINTAIN A SEPARATE LOG FOR EACH LOCATION. WHEN AN AREA IS

DIVIDED INTO SEPARATE SECTIONS, MAINTAIN A SEPARATE LOG FOR EACH SECTION.

Place Surface Profile

Replica Tape Here

Place Surface Profile

Replica Tape Here

Place Surface Profile

Replica Tape Here

Reading (mils): Reading (mils): Reading (mils):

Place Surface Profile

Replica Tape Here

Place Surface Profile

Replica Tape Here

Place Surface Profile

Replica Tape Here

Reading (mils): Reading (mils): Reading (mils):

Place Surface Profile

Replica Tape Here

Place Surface Profile

Replica Tape Here

Place Surface Profile

Replica Tape Here

Reading (mils): Reading (mils): Reading (mils):

Place Surface Profile

Replica Tape Here

Place Surface Profile

Replica Tape Here

Place Surface Profile

Replica Tape Here

Reading (mils): Reading (mils): Reading (mils):

Place Surface Profile

Replica Tape Here

Place Surface Profile

Replica Tape Here

Place Surface Profile

Replica Tape Here

Reading (mils): Reading (mils): Reading (mils):

MEAN MIL READING (IAW ASTM D4417-METHOD C) FOR ABOVE 15 READINGS:

10 (Rev-0)

QA-3b - QUALITY ASSURANCE INSPECTION FORM

(SURFACE PROFILE LOG FOR PROFILE MEASUREMENTS IAW ASTM D4417-METHOD-B)

VESSEL NAME HULL # WORK ITEM

SURFACE PREPARATION METHOD PROFILE ACHIEVED (MILS)

MIN MAX MEAN

SSPC-SP-10/NACE No. 2

SSPC-SP WJ-2/NACE WJ-2

SSPC-SP-3

SSPC-SP-11

SSPC-SP-11 (inaccessible area)

Brush-blasting (non-metallic substrate)

ABRASIVE MANUFACTURER: ABRASIVE SIEVE SIZE:

RECORD MEASUREMENTS TAKEN IN THE SPACES PROVIDED BELOW, TO SERVE AS PERMANENT

QA RECORD. MAINTAIN SEPARATE LOG FOR EACH LOCATION. WHEN AN AREA IS DIVIDED INTO

SEPARATE SECTIONS, MAINTAIN A SEPARATE LOG FOR EACH SECTION.

Reading (mils):

Reading (mils):

Reading (mils):

Reading (mils):

Reading (mils):

Reading (mils):

Reading (mils):

Reading (mils):

Reading (mils):

Reading (mils):

Mean Mils Reading (IAW ASTM D4417-Method B for above 10 readings (by column):

Mean Reading

(mils)

11 (Rev-0)

QA-4 - QUALITY ASSURANCE INSPECTION FORM

(SURFACE SOLUBLE SALT CONDUCTIVITY LOG)

VESSEL NAME HULL # WORK ITEM

SOLUBLE SALT CONDUCTIVITY MEASUREMENTS IAW SSPC-GUIDE 15.

DATE TEST LOCATIONS CONDUCTIVITY (MICROSIEMENS/CM)

NAME OF QP-1/NACE INSPECTOR SIGNATURE CERT. # DATE /

TIME

12 (Rev-0)

QA-5 - QUALITY ASSURANCE DATA FORM

(COATING THICKNESS)

(Use one sheet for each sequence)

VESSEL NAME HULL #

WORK ITEM

COATING MFG PRODUCT NAME

BATC

H #

INDUCTI

ON TIME

COATING SYSTEM

SEQUENCE

(PRIMER/TOUCHUP/3RD

COAT, ETC.)

DRY FILM THICKNESS (DFT) MEASUREMENTS IAW SSPC-PA 2.

SPOT 1 2 3 4 5

AVERAGE

VALUE

*BASE METAL READING

(BMR)

*Required, If Magnetic Pull-Off (Type I/Banana) Gauge Is Used.

LOCATION (FRAME REFERENCE):

SPOT 1 2 3 4 5 OVERALL AVG. DFT ADJUSTMENTS

1 AVG. BMR DEVIATION

3 BEFORE ADJUSTMENTS AFTER ADJUSTMENTS

AVG.

LOCATION (FRAME REFERENCE):

SPOT 1 2 3 4 5 OVERALL AVG. DFT ADJUSTMENTS

1 AVG. BMR DEVIATION

3 BEFORE ADJUSTMENTS AFTER ADJUSTMENTS

AVG.

LOCATION (FRAME REFERENCE):

SPOT 1 2 3 4 5 OVERALL AVG. DFT ADJUSTMENTS

1 AVG. BMR DEVIATION

3 BEFORE ADJUSTMENTS AFTER ADJUSTMENTS

AVG.

APPLICATION METHOD (AIRLESS,

CONVENTIONAL SPRAY, ROLLED)

AVERAGE DFT

13 (Rev-0)

4.2 Tank and Void Assessment form.

14 (Rev-0)

15 (Rev-0)

11000_SideScan_ESD_1021_FLT

REC_11000_Side_Scan_FLT_270’ WMEC ‘B’ Class (ALL) (0821)

WORK ITEM 1: Hull Plating, Side Scan, Ultrasonic Testing

1. SCOPE

1.1 Intent. This work item describes the requirements for the Contractor to perform thickness measurements of underwater (u/w) hull plating by ultrasonic side scan method.

1.2 Government-furnished property.

None.

2. REFERENCES

COAST GUARD DRAWINGS

Coast Guard Drawing 905 WMEC 111-001, Rev E, Shell Expansion Fwd 101

Coast Guard Drawing 905 WMEC 111-002, Rev F, Shell Exp Aft 182

Coast Guard Drawing 905 WMEC 111-003, Rev F, Shell Exp Fr 101-182

Coast Guard Drawing 905 WMEC 801-033, Rev F, Docking Plan USCGC SENECA

COAST GUARD PUBLICATIONS

Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2020, General Requirements

OTHER REFERENCES

American Society for Nondestructive Testing (ASNT) SNT-TC-1A, 2020, Recommended

Practice for Personal Qualification and Certification in Nondestructive Testing

3. REQUIREMENTS

3.1 General.

3.1.1 CIR. The Contractor must submit a CIR for the inspections listed in the following paragraph(s):

3.3 Side scan requirements and procedures.

3.1.2 Tech Rep.

Not applicable.

16 (Rev-0)

3.1.3 Protective measures. The Contractor must furnish and install all protective measures in accordance with SFLC Std Spec 0000, paragraph 3.3.3 (Vessel component, space, and equipment protection).

3.1.4 Interferences. The Contractor must handle all interferences in accordance with SFLC Std Spec 0000, paragraph 3.3.5 (Interferences). Known interferences include, but are not limited to the following:

Hull zinc anode system

Docking blocks

3.2 Work coordination and preparation. The Contractor must plan all specified vessel work detailed in this specification package to ensure the side scan survey does not necessitate a work stoppage. The

Contractor must abide by the following guidance, to facilitate the ultrasonic survey:

Ensure that all u/w body surface preparation and primer coat application tasks are completed within ten days of lifting the vessel.

Provide a continuous supply of fresh water at .50 gpm within 50 feet of the vessel with standard hose bib fitting.

Provide 110 VAC electrical power, and scaffolding or other suitable means of access to bring inspection personnel within one foot of all the body surface inspection areas that are five feet above ground level.

After completion of the hull survey, and authorized hull repairs, resume/complete u/w body preservation process by applying the second coat of the anti-corrosive coating system, and all anti-fouling paint coats.

Pay close attention to manufacturer’s recommended practices in regards to paint system overcoat time limitations and required…

This is the start of the file's text. The full file is on GovTribe.