SD MHLS 103 Market St Office Building Improvement Final.pdf
PDF 2 MB Posted
- Attached to
- Mid-Hudson Library System Office Building Structured Cabling System and 2nd Floor Improvement Project
- Solicitation number
- 2140010
- Issued by
- Dutchess County, New York
About this file
This is a construction document set containing architectural and engineering plans for the Mid-Hudson Library System office building located at 103 Market Street, Poughkeepsie, New York 12601. The project involves alterations and renovations to the second floor office layout and installation of a structured cabling system throughout the building. The scope of work includes demolition and removal of existing walls and dividers, installation of a drop ceiling and new lighting system on the second floor, reconfiguration of office spaces and accessory areas including a kitchenette and restroom, installation of new flooring (2'x2' carpet tiles in offices and 2'x2' floor tiles in common areas), and comprehensive upgrades to the fiber, switches, routers, access points, data lines, and data jacks on all floors. The plans are dated October 14, 2026, with sealed bids due November 9, 2026, at 1:00 PM. Site visits for contractors must be scheduled with Chris Herron, Facilities Manager, at 845-471-6060 extension 247 or cherron@midhudson.org. The project is being pursued for federal E-Rate program reimbursement eligibility where applicable.
The project requires prevailing wage rates and mandates that all contractors be registered with the New York State Department of Labor Contractor Registry. A performance bond is required upon contract signing, while security bid bonds, deposits, labor and material payment bonds have been waived. Bidding documents became available October 19, 2026, and are obtainable at the MHLS headquarters or via email request. No MWBE, DBE, or SDVOB contracting goals have been established for this procurement. No identical or substantially similar contracts have been awarded to any business within the past five years. The system will cooperate with the federal E-Rate program for eligible project costs. Bids must be submitted in duplicate, and any bids received after the opening time will be rejected; bidders may withdraw bids within 120 days after opening.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Prevailing Wage Schedule.pdf | ||
| RFP Final.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M
AR
KE
T
ST
RE
ET
EXISTING
AUDITORIUM
BUILDING
(105 MARKET ST)
- NOT IN SCOPE -EXISTING DRIVE /
PARKING
E
XI
S
TI
N G
D R
IV
E
THESE DRAWINGS ARE BASED ON ORIGINAL ARCHITECTURAL PLANS BY MIGUEL A. FRANCO AIA DATED 6/11/1965 AND PETER HOFFMAN AIA DATED 2/12/1992 WITH MINOR CHANGES & MANY NEW ADDED DETAILS NOT SHOWN. I.E. VENTS AND
FANS. VERIFY ALL CONDITIONS IN FIELD.
SHEET NO.
PROJECT NO.
DATE
DRAWN BY
IT IS UNLAWFUL TO MODIFY A DOCUMENT BEARING THE SEAL AND
SIGNATURE OF A REGISTERED ARCHITECT OR PROFESSIONAL ENGINEER
NOTE:
IN
IT
IA
L
P R
IC
IN
G P
LA
N
D R
A W
IN
G
S F
O R
M
ID
H U
D S
O N
L
IB
R A
R Y
S
YS
TE
M
M A
R K
E T
S
TR
E E
T
P
O U
G H
K E
E P
S
IE
, N Y
DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS TAKE PRECEDENCE.
IN CASE OF DISCREPANCIES OR CONFLICTS, NOTIFY DESIGN PROFESSIONAL.
P O
B O
X
K
IN
G
S
TO
N N
Y in fo sy ne rg yd es ig n.
or g
Y N E R G Y
E S
IG
N
A R
C H
IT
E
C
TU
R E
E
N G
IN
E
E R
IN
G
P
LL
C
IN
ITI
AL
PRIC
IN
G SE
T -
NOT F
OR C
ONSTRUCTIO
N
26-113
SH, JV
14 OCT 2026
REV. DATE
A
C O
VE
R
DRAWING INDEX:
A COVER
EX-1 EXISTING & DEMO SECOND FLOOR PLAN
A-1 SECOND FLOOR LAYOUT PLAN
A-2 SECOND FLOOR CONSTRUCTION PLAN
A-3 SECOND FLOOR FLOORING PLAN
A-4 INTERIOR SECTION & ELEVATIONS
RCP-1 SECOND FLOOR REFLECTED CEILING PLAN
E-1 SECOND FLOOR ELECTRICAL & LIGHTING PLAN
ED-1 FIRST FLOOR DATA PLAN
ED-2 SECOND FLOOR DATA PLAN
ED-3 THIRD FLOOR DATA PLAN
N NOTES
CERTIFICATION DISCLAIMER:
PLOT PLAN INFORMATION HERE PRESENTED FROM DUTCHESS
COUNTY PARCEL ACCESS DATA AND OTHER ONLINE
RESOURCES.
NO CERTIFICATION IS HERE GIVEN NOR IMPLIED FOR SAID
EXISTING BOUNDARY LOCATIONS, SITE FEATURES,
STRUCTURES, AND CONTOURS, ONLY FOR THEIR FAITHFUL
REPRESENTATION TO SERVE PURPOSES OF PRESENTING
PROPOSED SOLAR PV PLAN.
PROJECT SCOPE:
PROPOSED UPGRADE TO AND MOVING WHERE SHOWN OF
FIBER, SWITCHES, ROUTERS, ACCESS POINTS, DATA LINES,
AND DATA JACKS ON ALL FLOORS.
PROPOSED ALTERATIONS AND RENOVATIONS TO SECOND
FLOOR LAYOUT OF OFFICES AND ACCESSORY SPACES, TO
INCLUDE INSTALLATION OF A DROP CEILING AND LIGHTING
SYSTEM THROUGHOUT.
ZONING
DISTRICT
MIN. LOT
AREA
(SF) FRONT
MIN. SETBACKS
FOR YARDS (FT)
EACH TOTAL
BUILDING
HEIGHT
(LESSER OF)
LOT
COVERAGE
100%
MIN. LOT
WIDTH
(FT)
MIN. LOT
FRONTAGE
(FT)
USABLE
OPEN
SPACE
--C-2 NONE * * *
DISTRICT SCHEDULE OF AREA AND BULK REGULATIONS
40 PSF 115 SEVERE 48" SLIGHT TO
MODERATE
6° REQUIRED
FIRM MAP:
36027C0358E (5/2/2012)
GROUND
SNOW
LOAD SPEED
(MPH)
SUBJECT TO DAMAGE FROM
WEATHERING FROST LINE TERMITE
WINTER
DESIGN
TEMPERATURE
ICE SHIELD
UNDERLAYMENT
FLOOD
HAZARD
CLIMATE & GEOGRAPHIC DESIGN CRITERIA
WIND DESIGN
TOPOGRAPHIC
EFFECTS
SPECIAL
WIND REGION
WIND-BORNE
DEBRIS ZONE
SEISMIC
DESIGN
CATAGORY
AIR
FREEZING
INDEX
MEAN
ANNUAL
TEMP.
0.25 YES B 1160 --NO
REAR
SIDE
FLOOR
AREA
RATIO
2.0, BONUS
TO 8REQUIRED
-- ---- -- --25,700.4 -- -- -- -- --EXISTING
* FRONT YARD: WHERE THE BLOCK FRONTAGE IS LOCATED PARTLY IN THE C-2 DISTRICT AND PARTLY IN AN R-1 THROUGH R-6 OR O-R DISTRICT, THE FRONT YARD
REQUIREMENT OF THE R OR O-R DISTRICT SHALL APPLY IN THE C-2 DISTRICT.
SIDE YARDS:WHERE THE SIDE OF A LOT IN THE -2 DISTRICT ABUTS UPON THE SIDE OF A LOT IN AN R OR O-R DISTRICT, THERE SHALL BE A SIDE YARD OF NOT LESS THAN THE SIDE YARD REQUIRED IN THE ABUTTING R OR O-R DISTRICT. IN ALL OTHER CASES,M A SIDE YARD FOR A COMMERCIAL BUILDING SHALL NOT BE
REQUIRED, BUT, IF PROVIDED, HALL NOT BE LESS THAN SIX FEET IN WIDTH.
REAR YARD: WHERE THE C-2 DISTRICT ABUTS UPON AN R OR O-R DISTRICT, THERE SHALL BE A REAR YARD OF NOT LESS THAN FIFTEEN PERCENT OF THE DEPTH OF THE LOT, BUT SUCH REAR YARD NEED NOT EXCEED TWENTY FEET. IN ALL OTHER CASES, A REAR YARD IS NOT REQUIRED, EXCEPT IF ONE IS PROVIDED, IT SHALL NOT BE LESS THAN EIGHT FEET IN DEPTH. IN THE CASE OF A CORNER LOT ABUTTING A NONRESIDENTIAL DISTRICT ON BOTH STREETS, BOTH INTERIOR PROPERTY LINES SHALL BE CONSIDERED TO BE SIDE LOT LINES. (NOTE: THIS AVOIDS THE NEED FOR A REAR YARD ON A CORNER LOT IN A C-2 DISTRICT WHICH
WOULD DISRUPT THE CONTINUITY OF FRONTAGE).
FRONT (SOUTH) ELEVATION 2
1/4" = 1'-0"
PLOT PLAN3
1" = 20'
NORTH
PARCEL GRID IDENTIFICATION:
131300-6061-28-990966-0000
MUNICIPALITY: CITY OF POUGHKEEPSIE
PARCEL LOCATION:
103-105 MARKET STREET
PARCEL INFORMATION:
131300-6061-28-990966-0000
SIZE (ACRES): 0.59 AC(D)
LAND USE CLASS: (611) LIBRARY
DEED BOOK: 1544
DEED PAGE: 0760
SCHOOL DISTRICT: POUGHKEEPSIE - CITY CSD
AGRICULTURAL DISTRICT: NONE
ZONING DIST: C-2
PROJECT PROPERTY:
103-105 MARKET STREET
POUGHKEEPSIE, NY 12601
OWNER: MID HUDSON LIBRARY SYSTEM
LOCATION MAP1
1" = 500'
NORTH
A
A
A-1
PROJECT
ALTERATIONS AND RENOVATIONS TO EXISTING
OFFICE BUILDING @ 103 MARKET ST -
UPDN
ELEVATOR
ENCLOSED OFFICE 2-1
OUTREACH & SUSTAINABILITY
ADVOCACY & FUNDING
CLOSET /
STORAGE
IT OPERATIONS
SUPERVISOR
KITCHENETTE
ENCLOSED OFFICE
2-2
W/M
CLOSET
ELEC
PANEL
WIRES
THRU
WALL
WIRES
THRU
FLOOR
WIRES
THRU
WALL
WIRES
THRU
WALL
LIBRARY
SUSTAINABILITY
ASSISTANT
COMMUNICATION
SPECIALIST
DATA OPERATIONS
SUPERVISOR INTERLIBRARY LOAN
& CATALOGING
SPECIALIST
ILS & TECHNOLOGIES
OPERATIONS
SPECIALIST
IT SUPPORT
ENGINEER
ASSISTANT
OPERATIONS
MANAGER
ASSISTANT DIRECTOR
& TECHNOLOGIES
OPERATIONS
MANAGER
OUTREACH & EDI
SPECIALIST
TECH SUPPORT &
OPERATIONS
SPECIALIST
CATALOGING
SPECIALIST
OPERATIONS
MANAGER
2 3 5
6 7
15 16 13121110
PARTITION OFFICE 2-1
FIBER FROM ABOVE TO BELOW
FIBER FROM ABOVE TO BELOW
SD
T
$ VE
N T
VE
N T
F
VENT
SD
WIRES
THRU
WALL
WIRES
THRU
WALL
ACROSS
CLG
SD
T
VENT
WIRES
THRU
FLOOR
FI
R
S T
A
ID
H A
TC
H
HATCH
ELEV
CLG
J-BOX
CLG
J-BOX
DN UP
PROVIDE OPENING
FOR PROPOSED
RESTROOM EXHAUST
OUTLET
EXISTING BASE HEATING / COOLING TO REMAIN - TYP
NOTE:
1 DISCONNECT & SAVE ALL EXISTING FIRE / SMOKE
DETECTOR COMPONENTS, EMERGENCY EXIT
SIGNS, & SECUIRITY CAMERAS @ EXISTING CEILING
TO RE-INSTALL ON PROPOSED DROP CEILING IN
SAME LOCATIONS - TYP THROUGHOUT
DEMO & REMOVE EXISTING ELECTRICAL
PANEL - SALVAGE & REUSE ANY APPLICABLE
EXISTING WIRING TO SWITCHES & FIXTURES -
DEMO & REMOVE ANY UNUSED WIRING TO
ACHIEVE PROPOSED ELECTRICAL LAYOUT -
SEE SHEET E-1
DEMO & REMOVE ALL EXISTING CEILING
LIGHTS & ASSOCIATED WIRING - TYP
THROUGHOUT
DEMO & REMOVE ALL CEILING
FANS
DEMO & REMOVE EXISTING OUTLETS
& JUNCTION BOXES - TYP
THROUGHOUT;
CONTRACTOR TO REVIEW
PROPOSED ELECTRICAL PLANS FOR
ANY / ALL OUTLET LOCATIONS THAT
MAY ALLOW REUSE OF WIRING OR
EVEN OUTLET ITSELF AS PROXIMITY
& CONDITIONS MAY WARRANT -
COORDINATE IN FIELD;
SEE NOTE ABOVE FOR SYMBOL
LEGEND CONCERNING OUTLETS TO
LEAVE IN OR NEARLY IN PLACE
DEMO & REMOVE DATA & PHONE
JACKS & ASSOCIATED WIRING - TYP
THROUGHOUT ALL FLOORS
DEMO & REMOVE EXISTING DOOR -
OPEN EXISTING ADJACENT WALL AS
NECESSARY FOR REPLACEMENT
DOOR INSTALLATION & MOVED
LIGHT SWITCH
DEMO & REMOVE ALL EXISTING
WALLS & DIVIDERS FOR ALL AREAS
UNDER ALTERATION & RENOVATION
- REFERENCE SHEETS A-1 & A-2 FOR
SPECIFIC EXTENTS OF WORK - TYP
THROUGHOUT
DEMO & REMOVE EXISTING LAV SINK
& TOILET & APPLICABLE PORTION
OF / ACCESS FOR NEW PLUMBING
TO ALLOW FOR INSTALLATION OF
PROPOSED RESTROOM LAYOUT -
SEE SHEET A-1
DEMO EXISTING DOOR
NOTE:
OUTLETS DRAWN w/ A CIRCLE AROUND THEM ARE
TO BE ATTEMPTED TO BE KEPT IN OR NEARLY IN
PLACE - SEE SHEET E-1 FOR THE SAME OUTLETS
SHOWN ON THE PROPOSED ELECTRICAL PLAN
SHEET NO.
PROJECT NO.
DATE
DRAWN BY
IT IS UNLAWFUL TO MODIFY A DOCUMENT BEARING THE SEAL AND
SIGNATURE OF A REGISTERED ARCHITECT OR PROFESSIONAL ENGINEER
NOTE:
IN
IT
IA
L
P R
IC
IN
G P
LA
N
D R
A W
IN
G
S F
O R
M
ID
H U
D S
O N
L
IB
R A
R Y
S
YS
TE
M
M A
R K
E T
S
TR
E
U
G H
K E
E P
S
IE
, N Y
DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS TAKE PRECEDENCE.
IN CASE OF DISCREPANCIES OR CONFLICTS, NOTIFY DESIGN PROFESSIONAL.
P O
B O
X
K
IN
G
S
TO
N N
Y in fo sy ne rg yd es ig n.
or g
Y N E R G Y
E S
IG
N
A R
C H
IT
E
C
TU
R E
E
N G
IN
E
E R
IN
G
P
LL
C
IN
ITI
AL
PRIC
IN
G SE
T -
NOT F
OR C
ONSTRUCTIO
N
26-113
SH, JV
14 OCT 2026
REV. DATE
EX-1
E
XI
S
TI
N G
D
E M
O S
E C
O N
D F
LO
O
R P
LA
N
1/4" = 1'-0"EX-1
EXISTING & DEMO SECOND FLOOR PLAN
NORTH
UP
DN UP
DN
ELEVATOR
CLOSET /
STORAGE
KITCHENETTE
CLOSET
1 2 3 4 5 6 7 8 9
15 14
12 10
M/W
PRINTER /
COPIER
LIBRARY
SUSTAINABILITY
ASSISTANT
COMMUNICATION
SPECIALIST
ENCLOSED OFFICE 2-1
OUTREACH & SUSTAINABILITY
ADVOCACY & FUNDING
OUTREACH & EDI
SPECIALIST
INTERLIBRARY LOAN
& CATALOGING
SPECIALIST
CATALOGING
SPECIALIST
DATA OPERATIONS
SUPERVISOR
TECH SUPPORT &
OPERATIONS
SPECIALIST
IT SUPPORT
ENGINEER
IT WORK AREA
ILS & TECHNOLOGIES
OPERATIONS
SPECIALIST
ASSISTANT DIRECTOR
& TECHNOLOGIES
OPERATIONS
MANAGER ENCLOSED OFFICE
2-2
OPERATIONS
MANAGER
ASSISTANT
OPERATIONS
MANAGER
CENTRAL CORRIDOR
BLINDS & SLIDING
GLASS DOOR BETWEEN
OFFICE TEAM SPACES -
TYP THROUGHOUT
AWNING WINDOW GLASS w/ BLINDS @ OFFICE WALLS w/
CENTRAL CORRIDOR - TYP
THROUGHOUT
HALF GLASS DOORS w/ BLINDS
- TYP FOR ALL OFFICES
SOUND INSULATED WALLS -
TYP THROUGHOUT
146 SF
106 SF
106 SF
145 SF
106 SF 106 SF
106 SF
106 SF
126 SF
100 SF
151 SF138 SF
120 SF
150 SF
59 SF
151 SF
151 SF
IT OPERATIONS
SUPERVISOR
CHASE
120 SF
126 SF
STAIR -
WEST
STAIR -
EAST
877 SF
UPPER AWNING WINDOW
GLASS @ OFFICE WALLS w/
CENTRAL CORRIDOR - TYP
THROUGHOUT
2'x2' CARPET TILES IN
ALL OFFICES - TYP
THROUGHOUT - SEE
FLOORING PLAN
2'x2' FLOOR TILES IN
COMMON SPACE,
KITCHENETTE &
RESTROOM - SEE
FLOORING PLAN
NEW 2'x2' DROP
CEILING ABOVE - TYP
THROUGHOUT - SEE
REFLECTED CEILING
PLAN
FOR FLOOR FINISHES, SEE FLOORING PLAN
FOR CEILING LIGHTS, SEE REFLECTED CEILING PLAN
FOR ELECTRICAL OUTLETS & SWITCHES, SEE ELECTRICAL AND LIGHTING PLAN
FOR DATA JACKS & WIRING, SEE DATA PLANS
- TYP THROUGHOUT
NEW DOORS TO
KITCHENETTE & TO
RESTROOM - SEE
SHEET A-2
SHEET NO.
PROJECT NO.
DATE
DRAWN BY
IT IS UNLAWFUL TO MODIFY A DOCUMENT BEARING THE SEAL AND
SIGNATURE OF A REGISTERED ARCHITECT OR PROFESSIONAL ENGINEER
NOTE:
IN
IT
IA
L
P R
IC
IN
G P
LA
N
D R
A W
IN
G
S F
O R
M
ID
H U
D S
O N
L
IB
R A
R Y
S
YS
TE
M
M A
R K
E T
S
TR
E
U
G H
K E
E P
S
IE
, N Y
DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS TAKE PRECEDENCE.
IN CASE OF DISCREPANCIES OR CONFLICTS, NOTIFY DESIGN PROFESSIONAL.
P O
B O
X
K
IN
G
S
TO
N N
Y in fo sy ne rg yd es ig n.
or g
Y N E R G Y
E S
IG
N
A R
C H
IT
E
C
TU
R E
E
N G
IN
E
E R
IN
G
P
LL
C
IN
ITI
AL
PRIC
IN
G SE
T -
NOT F
OR C
ONSTRUCTIO
N
26-113
SH, JV
14 OCT 2026
REV. DATE
A-1
S E
C O
N D
F
LO
O R
L A
YO
U
T P
LA
N
1/4" = 1'-0"A-1
SECOND FLOOR LAYOUT PLAN
106'-0"
'-0
UP
DN UP
DN
11'-11" ±
VIF
'-0
8'-10"
'-0
8'-10"
'-0
12'-1"
'-0
8'-10"
'-0
8'-10"
'-0
8'-10"
'-0
8'-10"
'-0
12'-3" ±
VIF
'-0
8'-3 1/2" ±
VIF
2' -5
/2
10'-3 1/2" ±
VIF
'-8
/2
10'-3 1/2"
'-8
/2
11'-1 1/2" ±
VIF
'-8
/2
8' -8
/2
4'-7 1/2"
8'-0" ±
VIF
'-0
9'-5"
'-8
/2
13'-2" ±
VIF
'-8
/2
4' -9
/2
8'-10 1/2" ±
VIF
8'-7" ±
VIF
6' -1
1'-10 1/2"
6' -3
5'-7"
6'-8 1/2"
2'-5" 2'
-0
6' -6
15'-9 1/2" ±
VIF
4' -1
1"
4' -8
/2
4'-11"4'-2"
3' -2
'-8
/2
VI
F
76'-0 1/2" ±
VIF
5' -0
8'-3"
5' -8
/2
" 76'-2 1/2"
2'-2 1/2" 2'-11 1/2" 2'-11 1/2" 2'-11 1/2" 2'-11 1/2" 3'-9" 3'-9" 2'-11 1/2" 2'-11 1/2" 2'-11 1/2" 2'-11 1/2" 2'-11 1/2" 2'-11 1/2" 2'-11 1/2" 2'-11 1/2" 2'-3"
4'-0"
VIF
5' -0
5' -0
5' -0
5' -0
5' -0
5' -0
5' -4
/2
6' -9
/2
1' -1
0" 2'
-9
/2
3'-4" 3'-4" 3'-4" 3'-4"
3'-3" 2'-1" 2'-2"
3'-1 1/2" 3'-1 1/2"
5' -4
EX-D
EX-D
EX-D
EX-D
2-2 2-3
2-2
EX-W EX-W EX-W EX-W
EX-W
EX-W
EX-W
EX-W
201 201 201 201 201 201 201 201
201201 201201
2-2 2-2 2-2 2-2 2-2 2-2 2-2 2-2 2-2 2-2 2-22-3
2-3
2-42-4 2-4 2-4
2-2 2-2
1 1 1 1 1 1 1 1
EX
EX
EX
EX
EXEX
EX
EX
EX
EX
EX
EX
9'-1"
3'-11 1/2"
HOLD
4'-3 1/2"
HOLD
9' -1
1"
'-1
/2
VI
F
2 EX
PROJECT BASE REFERENCE
LOCATION - CENTERED ON
PROPOSED CENTRAL
CORRIDOR
A-4
A-4
TYP
TYP
5' -4
/2
203 203 203 203 203 203
203203
201 16 HALF GLASS
DOOR SCHEDULE:
ID: QTY: SIZE: DESCRIPTION: U-VALUE:
WINDOW SCHEDULE:
ID: SIZE:TYPE:
NOTE:
ALL WINDOWS TO BE LOW-E, LOW U-VALUE HIGH PERFORMANCE UNITS
QTY: U-VALUE:HEAD HT:
HEAD HT:
6'-8"
NOTES:
NOTES:
ADA COMPLIANT
SILL HT:
2-2 2'-0" x 3'-11 1/8"AWNING15 ---6'-8" MARVIN ELAWN 25472'-8 7/8"
2-3 3 ---
2-4 4 ---
202 1 3'-0" x 6'-8" SOLID ---
203 10 5'-0" x 6'-8" SLIDER ---6'-8" ---
3'-0" x 6'-8"
6'-8"
3'-4" x 3'-11 1/8"6'-8"
EX-W ---EXISTING TO REMAIN15 ------ ---
2'-4" x 3'-11 1/8"6'-8"
AWNING
AWNING
201 3'-0" x 1'-7 1/8"AWNING
OPTIONAL UPPER WINDOW SCHEDULE:
ID: SIZE:TYPE:
NOTE:
ALL WINDOWS TO BE LOW-E, LOW U-VALUE HIGH PERFORMANCE UNITS
QTY:
U-VALUE:
---8'-5 3/8"
HEAD HT: NOTES:
ABOVE DOORS 201 -
MARVIN ELAWN 3719
6'-10 1/4"
SILL HT:
2-2 2'-0" x 1'-7 1/8"AWNING15 --- MARVIN ELAWN 2519
2-3 3 --- MARVIN ELAWN 4119
2-4 4 --- MARVIN ELAWN 2919
3'-4" x 1'-7 1/8"
2'-4" x 1'-7 1/8"
AWNING
AWNING
EX-D 4 VARIES EXISTING TO REMAIN ------ ---
ADA COMPLIANT
2'-8 7/8"
2'-8 7/8"
MARVIN ELAWN 4147
MARVIN ELAWN 2947
8'-5 3/8" 6'-10 1/4"
8'-5 3/8" 6'-10 1/4"
8'-5 3/8" 6'-10 1/4"
2x4 @ 16" O.C. w/ SOUND ATTENUATING BATT INSULATION1
WALL TYPE SCHEDULE
EX
2x6 @ 16" O.C. w/ SOUND ATTENUATING BATT INSULATION
EXISTING WALLS TO REMAIN
SHEET NO.
PROJECT NO.
DATE
DRAWN BY
IT IS UNLAWFUL TO MODIFY A DOCUMENT BEARING THE SEAL AND
SIGNATURE OF A REGISTERED ARCHITECT OR PROFESSIONAL ENGINEER
NOTE:
IN
IT
IA
L
P R
IC
IN
G P
LA
N
D R
A W
IN
G
S F
O R
M
ID
H U
D S
O N
L
IB
R A
R Y
S
YS
TE
M
M A
R K
E T
S
TR
E
U
G H
K E
E P
S
IE
, N Y
DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS TAKE PRECEDENCE.
IN CASE OF DISCREPANCIES OR CONFLICTS, NOTIFY DESIGN PROFESSIONAL.
P O
B O
X
K
IN
G
S
TO
N N
Y in fo sy ne rg yd es ig n.
or g
Y N E R G Y
E S
IG
N
A R
C H
IT
E
C
TU
R E
E
N G
IN
E
E R
IN
G
P
LL
C
IN
ITI
AL
PRIC
IN
G SE
T -
NOT F
OR C
ONSTRUCTIO
N
26-113
SH, JV
14 OCT 2026
REV. DATE
A-2
S E
C O
N D
F
LO
O R
C O
N S
TR
U
C
TI
O N
P
LA
N
1/4" = 1'-0"A-2
SECOND FLOOR CONSTRUCTION PLAN
NORTH
NOTE:
ALL DIMENSIONS ARE RELATIVE TO PROJECT BASE REFERENCE
LOCATION AND THEREFORE, GIVEN WORKING WITHIN EXISTING
BUILDING, ALL DIMENSIONS ARE IN FACT TO BE VERIFIED IN FIELD BY
CONTRACTOR TO ENSURE DESIGN INTENT AND ALIGNMENTS ARE
REALIZED. COORDINATE WITH ARCHITECT AFTER DEMO OF
APPLICABLE CONSTRUCTION AND PRIOR TO NEW CONSTRUCTION.
FOR FLOOR FINISHES, SEE FLOORING PLAN
FOR CEILING LIGHTS, SEE REFLECTED CEILING PLAN
FOR ELECTRICAL OUTLETS AND SWITCHES, SEE ELECTRICAL AND
LIGHTING PLAN
FOR DATA JACKS AND WIRING, SEE DATA PLANS
- TYP THROUGHOUT
SEE INTERIOR WALL SECTION DETAIL, SHEET A-4
CARPET FLOORING IN
ALL OFFICES - TYP
2' x 2' TILE FLOORING IN
KITCHENETTE, RESTROOM &
COMMON CORRIDOR - TYP
THRESHOLD
T-1 T-1 T-1 T-1 T-1 T-1 T-1 T-1 T-1
T-1 T-1 T-1
T-4
T-4
T-4
T-1
EX-F
T-1 T-1T-2
T-4 T-3
F-1
EX-F EX-F
F-1
F-1
F-2
F-2F-2F-2F-2F-2
F-2F-2F-2F-2F-2F-2F-2F-2F-2
TILE LAYOUT NOTE: VERIFY ALL DIMENSIONS IN
FIELD. CENTER PATTERN AS SHOWN - START
LAYOUT AT CENTER OF CORRIDOR AS
PRESENTED.
INSTALL NEW 2' x 2' TILE FLOORING IN CENTRAL
CORRIDOR.
F-1 F-1
F-1
DN UP
FLOORING SCHEDULE
2' x 2' COLOREX TILE FLOORING BY FORBO - IN
KITCHENETTE, RESTROOM, AND COMMON
CORRIDOR - TYP
2' x 2' CARPET TILE FLOOR - IN ALL OFFICES - TYP
EXISTING FLOORING TO REMAIN
F-1
F-2
EX-F
THRESHOLD SCHEDULE
FLOOR TILE TO CARPET TILE TRANSITION
VISUAL TRANSITION BAND FROM CORRIDOR TO
RESTROOM
ELEVATOR CAR TO FLOOR TILE TRANSITION
EXISTING CONCRETE FLOOR TO FLOOR TILE
TRANSITION
T-1
T-2
T-3
T-4
SHEET NO.
PROJECT NO.
DATE
DRAWN BY
IT IS UNLAWFUL TO MODIFY A DOCUMENT BEARING THE SEAL AND
SIGNATURE OF A REGISTERED ARCHITECT OR PROFESSIONAL ENGINEER
NOTE:
IN
IT
IA
L
P R
IC
IN
G P
LA
N
D R
A W
IN
G
S F
O R
M
ID
H U
D S
O N
L
IB
R A
R Y
S
YS
TE
M
M A
R K
E T
S
TR
E
U
G H
K E
E P
S
IE
, N Y
DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS TAKE PRECEDENCE.
IN CASE OF DISCREPANCIES OR CONFLICTS, NOTIFY DESIGN PROFESSIONAL.
P O
B O
X
K
IN
G
S
TO
N N
Y in fo sy ne rg yd es ig n.
or g
Y N E R G Y
E S
IG
N
A R
C H
IT
E
C
TU
R E
E
N G
IN
E
E R
IN
G
P
LL
C
IN
ITI
AL
PRIC
IN
G SE
T -
NOT F
OR C
ONSTRUCTIO
N
26-113
SH, JV
14 OCT 2026
REV. DATE
A-3
S E
C O
N D
F
LO
O R
F
LO
O R
IN
G
P
LA
N
1/4" = 1'-0"A-3
SECOND FLOOR FLOORING PLAN
2' x 2' FLOOR TILE IN COMMON SPACE - TYP
1x3 BASE TRIM, PAINTED - TYP
1/2" GWB, PAINTED - TYP
16" O.C WOOD STUD PARTITION WALL w/
SOUND ATTENUATING BATT INSULATION -
2x4 OR 2x6 PER WALL TYPE NOTES ON PLAN
- TYP
2x4 DOUBLE TOP PLATE - HILTI TO
CONCRETE
2x4 BOTTOM PLATE - HILTI TO CONCRETE
2' x 2' COMMERCIAL CARPET TILE IN OFFICES - TYP
DROP CEILING GRID & ACT
ATTACH HANGER CABLE w/ HILTI
CONNECTORS TO CONCRETE - TYP
9' -0
8' -6
T
O B
E V
E R
IF
IE
D F
E A
S
IB
LE
UPPER OPENINGS w/ AWNING UNITS
SHEET NO.
PROJECT NO.
DATE
DRAWN BY
IT IS UNLAWFUL TO MODIFY A DOCUMENT BEARING THE SEAL AND
SIGNATURE OF A REGISTERED ARCHITECT OR PROFESSIONAL ENGINEER
NOTE:
IN
IT
IA
L
P R
IC
IN
G P
LA
N
D R
A W
IN
G
S F
O R
M
ID
H U
D S
O N
L
IB
R A
R Y
S
YS
TE
M
M A
R K
E T
S
TR
E
U
G H
K E
E P
S
IE
, N Y
DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS TAKE PRECEDENCE.
IN CASE OF DISCREPANCIES OR CONFLICTS, NOTIFY DESIGN PROFESSIONAL.
P O
B O
X
K
IN
G
S
TO
N N
Y in fo sy ne rg yd es ig n.
or g
Y N E R G Y
E S
IG
N
A R
C H
IT
E
C
TU
R E
E
N G
IN
E
E R
IN
G
P
LL
C
IN
ITI
AL
PRIC
IN
G SE
T -
NOT F
OR C
ONSTRUCTIO
N
26-113
SH, JV
14 OCT 2026
REV. DATE
A-4
IN
TE
R
IO
R S
E C
TI
O
N
E
LE
VA
TI
O N
S
1/2" = 1'-0"A-4
INTERIOR WALL SECTION DETAIL - TYP
1/2" = 1'-0"A-4
INTERIOR OFFICE ENTRANCE ELEVATION 3
1/2" = 1'-0"A-4
INTERIOR OFFICE SHARED PARTITION ELEVATION
SEE WINDOW AND DOOR
SCHEDULE ON SHEET A-2
DROP CEILING THROUGHOUT
WHERE SHOWN - TYP
RESTROOM EXHAUST - SEE
ELECTRICAL & LIGHTING PLAN
2' x 2' LIGHTS - SEE ELECTRICAL
& LIGHTING PLAN
CEILING TILE GRID LAYOUT NOTE: VERIFY ALL
DIMENSIONS IN FIELD. CENTER PATTERN AS
SHOWN - START LAYOUT ABOVE CENTER OF
CORRIDOR AS PRESENTED. CEILING GRID IS TO
ALIGN EXACTLY WITH FLOOR TILE LAYOUT
BELOW.
INSTALL NEW 2' x 2' ARMSTRONG OPTIMA 9/16"
TEGULAR SQUARE TILE & SILHOUETTE 1/4"
BOLT-SLOT DROP CEILING TILE / GRID
THROUGHOUT AS SHOWN ON PLAN
DN UP
DIMMABLE, TUNABLE (2700 - 6500 K) 2'x2'
FINELITE HPT LED CEILING GRID LIGHTS - TYP
THROUGHOUT ALL OFFICE SPACES
DIMMABLE, TUNABLE (3000 - 6000 K) 2'x2'
LITELINE LEDP-22-WH-TW-2-MT LED CEILING
GRID LIGHTS - TYP THROUGHOUT COMMON
SPACES, KITCHENETTE & RESTROOM
EXISTING OUTLETS, SWITCHES, & LIGHTING IN
SPACES OUTSIDE OF PROJECT SCOPE TO
REMAIN AS IS - NOT HERE SHOWN - TYP
RECESSES CEILING GRID &
CEILING TILE TO ALLOW FOR
UNOBSTRUCTED ACCESS TO
RETURN GRILLE
SHEET NO.
PROJECT NO.
DATE
DRAWN BY
IT IS UNLAWFUL TO MODIFY A DOCUMENT BEARING THE SEAL AND
SIGNATURE OF A REGISTERED ARCHITECT OR PROFESSIONAL ENGINEER
NOTE:
IN
IT
IA
L
P R
IC
IN
G P
LA
N
D R
A W
IN
G
S F
O R
M
ID
H U
D S
O N
L
IB
R A
R Y
S
YS
TE
M
M A
R K
E T
S
TR
E
U
G H
K E
E P
S
IE
, N Y
DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS TAKE PRECEDENCE.
IN CASE OF DISCREPANCIES OR CONFLICTS, NOTIFY DESIGN PROFESSIONAL.
P O
B O
X
K
IN
G
S
TO
N N
Y in fo sy ne rg yd es ig n.
or g
Y N E R G Y
E S
IG
N
A R
C H
IT
E
C
TU
R E
E
N G
IN
E
E R
IN
G
P
LL
C
IN
ITI
AL
PRIC
IN
G SE
T -
NOT F
OR C
ONSTRUCTIO
N
26-113
SH, JV
14 OCT 2026
REV. DATE
RCP-1
S E
C O
N D
F
LO
O R
R E
FL
E
C
TE
D C
E
IL
IN
G
P
LA
N
1/4" = 1'-0"RCP-1
SECOND FLOOR REFLECTED CEILING PLAN
$D $D $D $ $D
$D
$D$D$D$D$D$D$D$D $D
$D
$4
$4
$4
ELEC
PANEL
DN UP
PROPOSED
EXHAUST FAN
OUTLET
DIMMABLE, TUNABLE (2700 - 6500 K) 2'x2'
FINELITE HPT LED CEILING GRID LIGHTS - TYP
THROUGHOUT ALL OFFICE SPACES
DIMMABLE, TUNABLE (3000 - 6000 K) 2'x2'
LITELINE LEDP-22-WH-TW-2-MT LED CEILING
GRID LIGHTS - TYP THROUGHOUT COMMON
SPACES, KITCHENETTE & RESTROOM
EXISTING OUTLETS, SWITCHES, & LIGHTING IN
SPACES OUTSIDE OF PROJECT SCOPE TO
REMAIN AS IS - NOT HERE SHOWN - TYP
PANASONIC WHISPERVALUE DC VENTILATION
FAN FV-0510VS1 OR EQUAL - CONTRACTOR TO
PROVIDE FLANGE AS NECESSARY FOR
INSTALLATION IN 2'x2' CEILING GRID
GFCI GFCI GFCI
GFCI GFCI GFCI GFCI GFCI GFCI
GFCI
GFCI
GFCI
GFCI
GFCI
GFCI GFCI
GFCI GFCI
GFCI GFCI
UPDATE ELECTRICAL PANEL TO STANDARD
CURRENT BREAKERS
GFCI
ELECTRICAL LEGEND
SWITCH, DIMMABLE
SWITCH, 4-POLE
DUPLEX RECEPTACLE
DUPLEX RECEPTACLE (GROUND FAULT INTERRUPTER)
2' x 2' CEILING LIGHT - SEE NOTES FOR TYPE
EXISTING ELECTRICAL PANEL
ELECTRICAL WIRING
ELEC
PANEL
$D
$4
GFCI
SHEET NO.
PROJECT NO.
DATE
DRAWN BY
IT IS UNLAWFUL TO MODIFY A DOCUMENT BEARING THE SEAL AND
SIGNATURE OF A REGISTERED ARCHITECT OR PROFESSIONAL ENGINEER
NOTE:
IN
IT
IA
L
P R
IC
IN
G P
LA
N
D R
A W
IN
G
S F
O R
M
ID
H U
D S
O N
L
IB
R A
R Y
S
YS
TE
M
M A
R K
E T
S
TR
E
U
G H
K E
E P
S
IE
, N Y
DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS TAKE PRECEDENCE.
IN CASE OF DISCREPANCIES OR CONFLICTS, NOTIFY DESIGN PROFESSIONAL.
P O
B O
X
K
IN
G
S
TO
N N
Y in fo sy ne rg yd es ig n.
or g
Y N E R G Y
E S
IG
N
A R
C H
IT
E
C
TU
R E
E
N G
IN
E
E R
IN
G
P
LL
C
IN
ITI
AL
PRIC
IN
G SE
T -
NOT F
OR C
ONSTRUCTIO
N
26-113
SH, JV
14 OCT 2026
REV. DATE
E-1
S E
C O
N D
F
LO
O R
E
LE
C
TR
IC
A
L
L
IG
H
TI
N G
P
LA
N
1/4" = 1'-0"E-1
SECOND FLOOR ELECTRICAL & LIGHTING PLAN
ELECT METER
& MAIN PANEL
FURNACE
AIR
HANDLER
ELEVATOR
HYDRAULIC
UP
UP
DN
DN
ELEVATOR
KITCHENETTE
CONFERENCE ROOM
ENCLOSED OFFICE
1-1
EXECUTIVE DIRECTOR
OFFICE
SHIPPING ROOM
WOMENS BATH
W/M BATH
CLOSET / STORAGE
UTILITY ROOM
ELEC
PANEL
ENTRY
ENTRY
LOADING DOCKOVERHEAD DOOR
CLOSET
ELEC
PANEL
WIRES
THRU
WALL
PARTITION OFFICE 1-1
FRONT DESK
4 6
PR
PR
PR R
AP
FIBER FROM ABOVE
R
AP
AS FS
SOLAR SYSTEM OUTLET - 1 WIRE
COMMUNICATION SYMBOLS
DATA OUTLET w/ 2 JACKS. PROVIDE & INSTALL (2) CAT-6A CABLES FROM
OUTLET LOCATION TO AT OR ABOVE CEILING, AS APPLICABLE, EACH IN 3 4"
CONDUIT. MOUNT OUTLET 18" AFF UNLESS OTHERWISE NOTED.
PRINTER OUTLET. PROVIDE & INSTALL CAT-6A FROM OUTLET LOCATION TO AT
OR ABOVE CEILING, AS APPLICABLE, EACH IN 3 4" CONDUIT. MOUNT OUTLET 18"
AFF UNLESS OTHERWISE NOTED.
PR
COPIER OUTLET. PROVIDE & INSTALL CAT-6A FROM OUTLET LOCATION TO AT OR
ABOVE CEILING, AS APPLICABLE, EACH IN 3 4" CONDUIT. MOUNT OUTLET 18" AFF
UNLESS OTHERWISE NOTED.
CO
SS
CAMERA NVR OUTLET - 1 WIRENVR
FS
R ROUTER
LAYER 3 CORE FIBER SWITCH - 48 PORT
CAT 6A WIRE - 1 OR 2 DEPENDING ON CONNECTION - SEE LEGEND ABOVE
FIBER LINE WIRE
R WIRELESS ROUTER ACCESS POINT - 1 WIRE - POE
AP
AS ACCESS SWITCH - VLAN - w/ POE - 48 PORT
DATA OUTLET w/ 1 JACK. PROVIDE & INSTALL (1) CAT-6A CABLES FROM
OUTLET LOCATION TO AT OR ABOVE CEILING, AS APPLICABLE, EACH IN 3 4"
CONDUIT. MOUNT OUTLET 18" AFF UNLESS OTHERWISE NOTED.
NOTE:
ALL JACKS SHALL BE TERMINATED WITH A COMPATIBLE CAT 6A KEYSTONE
TO ALLOW FOR UP TO 10 GBPS.
FW FIREWALL - PALO ALTO NEXT GEN
SHEET NO.
PROJECT NO.
DATE
DRAWN BY
IT IS UNLAWFUL TO MODIFY A DOCUMENT BEARING THE SEAL AND
SIGNATURE OF A REGISTERED ARCHITECT OR PROFESSIONAL ENGINEER
NOTE:
IN
IT
IA
L
P R
IC
IN
G P
LA
N
D R
A W
IN
G
S F
O R
M
ID
H U
D S
O N
L
IB
R A
R Y
S
YS
TE
M
M A
R K
E T
S
TR
E
U
G H
K E
E P
S
IE
, N Y
DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS TAKE PRECEDENCE.
IN CASE OF DISCREPANCIES OR CONFLICTS, NOTIFY DESIGN PROFESSIONAL.
P O
B O
X
K
IN
G
S
TO
N N
Y in fo sy ne rg yd es ig n.
or g
Y N E R G Y
E S
IG
N
A R
C H
IT
E
C
TU
R E
E
N G
IN
E
E R
IN
G
P
LL
C
IN
ITI
AL
PRIC
IN
G SE
T -
NOT F
OR C
ONSTRUCTIO
N
26-113
SH, JV
14 OCT 2026
REV. DATE
ED-1
FI
R
S T
FL
O
O R
D A
TA
P
LA
N
1/4" = 1'-0"ED-1
FIRST FLOOR DATA PLAN
NORTH
ALL IT EQUIPMENT BRAND SPECIFICATION PER OWNER NETWORK / IT
ENGINEER PREFERENCE - TYPICAL THROUGHOUT
ALL EXISTING STRUCTURED CABLING SYSTEM COMPONENTS TO BE
REMOVED THROUGHOUT
UP
DN UP
DN
ELEVATOR
CLOSET /
STORAGE
KITCHENETTE
CLOSET
1 2 3 4 5 6 7 8 9
15 14
12 10
M/W
PRINTER /
COPIER
LIBRARY
SUSTAINABILITY
ASSISTANT
COMMUNICATION
SPECIALIST
ENCLOSED OFFICE 2-1
OUTREACH & SUSTAINABILITY
ADVOCACY & FUNDING
OUTREACH & EDI
SPECIALIST
INTERLIBRARY LOAN
& CATALOGING
SPECIALIST
CATALOGING
SPECIALIST
DATA OPERATIONS
SUPERVISOR
TECH SUPPORT &
OPERATIONS
SPECIALIST
IT SUPPORT
ENGINEER
IT WORK AREA
ILS & TECHNOLOGIES
OPERATIONS
SPECIALIST
ASSISTANT DIRECTOR
& TECHNOLOGIES
OPERATIONS
MANAGER ENCLOSED OFFICE
2-2
OPERATIONS
MANAGER
ASSISTANT
OPERATIONS
MANAGER
CENTRAL CORRIDOR
FIBER FROM ABOVE TO BELOW
FIBER FROM ABOVE
P R
C O
146 SF
106 SF
106 SF
145 SF
106 SF 106 SF
106 SF
106 SF
126 SF
100 SF
151 SF138 SF
120 SF
150 SF
59 SF
151 SF
151 SF
IT OPERATIONS
SUPERVISOR
CHASE
120 SF
126 SF
STAIR -
WEST
STAIR -
EAST
877 SF
ELEC
PANEL
AS
R
AP
SOLAR SYSTEM OUTLET - 1 WIRE
COMMUNICATION SYMBOLS
DATA OUTLET w/ 2 JACKS. PROVIDE & INSTALL (2) CAT-6A CABLES FROM
OUTLET LOCATION TO AT OR ABOVE CEILING, AS APPLICABLE, EACH IN 3 4"
CONDUIT. MOUNT OUTLET 18" AFF UNLESS OTHERWISE NOTED.
PRINTER OUTLET. PROVIDE & INSTALL CAT-6A FROM OUTLET LOCATION TO AT
OR ABOVE CEILING, AS APPLICABLE, EACH IN 3 4" CONDUIT. MOUNT OUTLET 18"
AFF UNLESS OTHERWISE NOTED.
PR
COPIER OUTLET. PROVIDE & INSTALL CAT-6A FROM OUTLET LOCATION TO AT OR
ABOVE CEILING, AS APPLICABLE, EACH IN 3 4" CONDUIT. MOUNT OUTLET 18" AFF
UNLESS OTHERWISE NOTED.
CO
SS
CAMERA NVR OUTLET - 1 WIRENVR
FS
R ROUTER
LAYER 3 CORE FIBER SWITCH - 48 PORT
CAT 6A WIRE - 1 OR 2 DEPENDING ON CONNECTION - SEE LEGEND ABOVE
FIBER LINE WIRE
R WIRELESS ROUTER ACCESS POINT - 1 WIRE - POE
AP
AS ACCESS SWITCH - VLAN - w/ POE - 48 PORT
DATA OUTLET w/ 1 JACK. PROVIDE & INSTALL (1) CAT-6A CABLES FROM
OUTLET LOCATION TO AT OR ABOVE CEILING, AS APPLICABLE, EACH IN 3 4"
CONDUIT. MOUNT OUTLET 18" AFF UNLESS OTHERWISE NOTED.
NOTE:
ALL JACKS SHALL BE TERMINATED WITH A COMPATIBLE CAT 6A KEYSTONE
TO ALLOW FOR UP TO 10 GBPS.
FW FIREWALL - PALO ALTO NEXT GEN
SHEET NO.
PROJECT NO.
DATE
DRAWN BY
IT IS UNLAWFUL TO MODIFY A DOCUMENT BEARING THE SEAL AND
SIGNATURE OF A REGISTERED ARCHITECT OR PROFESSIONAL ENGINEER
NOTE:
IN
IT
IA
L
P R
IC
IN
G P
LA
N
D R
A W
IN
G
S F
O R
M
ID
H U
D S
O N
L
IB
R A
R Y
S
YS
TE
M
M A
R K
E T
S
TR
E
U
G H
K E
E P
S
IE
, N Y
DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS TAKE PRECEDENCE.
IN CASE OF DISCREPANCIES OR CONFLICTS, NOTIFY DESIGN PROFESSIONAL.
P O
B O
X
K
IN
G
S
TO
N N
Y in fo sy ne rg yd es ig n.
or g
Y N E R G Y
E S
IG
N
A R
C H
IT
E
C
TU
R E
E
N G
IN
E
E R
IN
G
P
LL
C
IN
ITI
AL
PRIC
IN
G SE
T -
NOT F
OR C
ONSTRUCTIO
N
26-113
SH, JV
14 OCT 2026
REV. DATE
ED-2
S E
C O
N D
F
LO
O R
D A
TA
P
LA
N
1/4" = 1'-0"ED-2
SECOND FLOOR DATA PLAN
NORTH
ALL IT EQUIPMENT BRAND SPECIFICATION PER OWNER NETWORK / IT
ENGINEER PREFERENCE - TYPICAL THROUGHOUT
FIBER TO BELOW
ELEVATOR
DN
DN
UP
RAMPLANDING
COMPUTER
OPERATIONS 3-1
COMPUTER
OPERATION 3-2
MECHANICAL
PODCAST OFFICE
CLOSET / STORAGE
T
DATA ROOM
ELEC
PANEL
DATA
ENTRY -
FIBER
ELEC
PANEL
ELEC
PANEL
ELEC
PANEL PARTITION OFFICE 3-1
OPEN AREA
SS
NVR
NVR
FS
FIBER TO BELOW
LAYER 3 CORE SWITCH MAIN FIBER LINE TO / FROM EXTERIOR
FIBER LINE FOR ENTIRETY OF FIRST FLOOR
FIBER LINE FOR ENTIRETY OF SECOND FLOOR
FW
FIREWALL
SOLAR SYSTEM OUTLET - 1 WIRE
COMMUNICATION SYMBOLS
DATA OUTLET w/ 2 JACKS. PROVIDE & INSTALL (2) CAT-6A CABLES FROM
OUTLET LOCATION TO AT OR ABOVE CEILING, AS APPLICABLE, EACH IN 3 4"
CONDUIT. MOUNT OUTLET 18" AFF UNLESS OTHERWISE NOTED.
PRINTER OUTLET. PROVIDE & INSTALL CAT-6A FROM OUTLET LOCATION TO AT
OR ABOVE CEILING, AS APPLICABLE, EACH IN 3 4" CONDUIT. MOUNT OUTLET 18"
AFF UNLESS OTHERWISE NOTED.
PR
COPIER OUTLET. PROVIDE & INSTALL CAT-6A FROM OUTLET LOCATION TO AT OR
ABOVE CEILING, AS APPLICABLE, EACH IN 3 4" CONDUIT. MOUNT OUTLET 18" AFF
UNLESS OTHERWISE NOTED.
CO
SS
CAMERA NVR OUTLET - 1 WIRENVR
FS
R ROUTER
LAYER 3 CORE FIBER SWITCH - 48 PORT
CAT 6A WIRE - 1 OR 2 DEPENDING ON CONNECTION - SEE LEGEND ABOVE
FIBER LINE WIRE
R WIRELESS ROUTER ACCESS POINT - 1 WIRE - POE
AP
AS ACCESS SWITCH - VLAN - w/ POE - 48 PORT
DATA OUTLET w/ 1 JACK. PROVIDE & INSTALL (1) CAT-6A CABLES FROM
OUTLET LOCATION TO AT OR ABOVE CEILING, AS APPLICABLE, EACH IN 3 4"
CONDUIT. MOUNT OUTLET 18" AFF UNLESS OTHERWISE NOTED.
NOTE:
ALL JACKS SHALL BE TERMINATED WITH A COMPATIBLE CAT 6A KEYSTONE
TO ALLOW FOR UP TO 10 GBPS.
FW FIREWALL - PALO ALTO NEXT GEN
SHEET NO.
PROJECT NO.
DATE
DRAWN BY
IT IS UNLAWFUL TO MODIFY A DOCUMENT BEARING THE SEAL AND
SIGNATURE OF A REGISTERED ARCHITECT OR PROFESSIONAL ENGINEER
NOTE:
IN
IT
IA
L
P R
IC
IN
G P
LA
N
D R
A W
IN
G
S F
O R
M
ID
H U
D S
O N
L
IB
R A
R Y
S
YS
TE
M
M A
R K
E T
S
TR
E
U
G H
K E
E P
S
IE
, N Y
DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS TAKE PRECEDENCE.
IN CASE OF DISCREPANCIES OR CONFLICTS, NOTIFY DESIGN PROFESSIONAL.
P O
B O
X
K
IN
G
S
TO
N N
Y in fo sy ne rg yd es ig n.
or g
Y N E R G Y
E S
IG
N
A R
C H
IT
E
C
TU
R E
E
N G
IN
E
E R
IN
G
P
LL
C
IN
ITI
AL
PRIC
IN
G SE
T -
NOT F
OR C
ONSTRUCTIO
N
26-113
SH, JV
14 OCT 2026
REV. DATE
ED-3
TH
IR
D F
LO
O
R D
A
TA
P
LA
N
1/4" = 1'-0"ED-3
THIRD FLOOR DATA PLAN
NORTH
ALL IT EQUIPMENT BRAND SPECIFICATION PER OWNER NETWORK / IT
ENGINEER PREFERENCE - TYPICAL THROUGHOUT
GENERAL NOTES
1. ALL WORK PERFORMED SHALL COMPLY WITH THE BUILDING AND ZONING ORDINANCES OF THE CITY OF POUGHKEEPSIE AND THE BUILDING CODE OF NEW
YORK STATE.
2. ALL FEDERAL, STATE AND LOCAL CODES, ORDINANCES, REGULATIONS, ETC. SHALL BE CONSIDERED AS PART OF THE SPECIFICATIONS FOR THIS BUILDING AND SHALL TAKE PRECEDENCE OVER ANYTHING SHOWN, DESCRIBED OR IMPLIED WHEN SAME ARE AT VARIANCE.
3. THESE PLANS ARE TO BE USED FOR PERMITS AND CONSTRUCTION GUIDE ONLY. IT IS NOT INTENDED TO BE USED AS A CONTRACT DOCUMENT UNLESS
OTHERWISE INDICATED BY ARCHITECT.
4. CONTRACTOR OR ANY SUBCONTRACTOR DOING ANY WORK UNDER THIS CONTRACT SHALL CARRY LIABILITY, WORKMAN'S COMPENSATION AND PROPERTY DAMAGE INSURANCE AGAINST ACCIDENTS OF ALL KINDS. THE OWNER SHALL EFFECT FIRE, LIGHTENING AND ANY OTHER INSURANCE AS REQUIRED, IN PROPER SUMS TO COVER THE COST OF THE WORK IN PLACE. THE CONTRACTOR AND SUB-CONTRACTORS SHALL ADD OWNER ONTO ALL POLICIES AND FURNISH OWNER
WITH ALL CERTIFICATES OF INSURANCE.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING ALL DIMENSIONS ON THESE PLANS AGAINST FIELD CONDITIONS PRIOR TO CONSTRUCTION AND
REPORT ANY DISCREPANCIES TO THE ARCHITECT.
6. ALL DIMENSIONS AND LOCATIONS AS INDICATED ON THE DRAWINGS SHALL BE CONSIDERED AS REASONABLY CORRECT, BUT IT SHALL BE UNDERSTOOD THAT THEY ARE SUBJECT TO MODIFICATION AS MAY BE NECESSARY OR DESIRABLE AT THE TIME OF INSTALLATION TO MEET ANY UNFORESEEN OR OTHER CONDITION.
7. ARCHITECT AND RELATED CONSULTANTS HAVE NOT BEEN RETAINED FOR CONSTRUCTION INSPECTION OR CONTRACT ADMINISTRATION SERVICES. IT REMAINS INCUMBENT ON THE CONTRACTOR TO INFORM THE BUILDING DEPARTMENT AND THE ARCHITECT OF ANY DISCREPANCY OR CHANGE ON APPROVED PLANS AND OF ANY UNFORESEEN DEVELOPMENT THAT MAY OCCUR DURING THE COURSE OF CONSTRUCTION.
8. ARCHITECT ASSUMES NO RESPONSIBILITY FOR ANY EXISTING STRUCTURE OR ANY UNFORESEEN PROBLEMS PRIOR TO CONSTRUCTION. ARCHITECT ASSUMES NO RESPONSIBILITY FOR ANY CONSTRUCTION AND/OR DEMOLITION OPERATIONS, MEANS AND METHODS.
9. CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH EXISTING CONDITIONS, INCLUDING HOW NEW WORK WILL AFFECT EXISTING TENANT SPACES. IN THE EVENT CONSTRUCTION AFFECTS EXISTING TENANT SPACES, OR THE GENERAL CONTRACTOR REQUIRES THAT AREAS IN TENANT SPACES NEED TO BE SECURED, CORDONED OFF OR ALTERED IN ANY WAY, THE G.C. SHALL NOTIFY THE BUILDING OWNER MINIMUM 7 DAYS PRIOR AND A SEQUENCING PLAN MUST BE PROVIDED IN WRITING. WORK AREAS IN EXISTING SPACES MUST BE CLOSED OFF TO PREVENT DUST FROM ESCAPING.
10. ALL DIMENSIONS ARE APPROXIMATE AND ARE TO BE FIELD VERIFIED PRIOR TO START OF WORK. DO NOT SCALE DIMENSIONS FROM DRAWINGS. WRITTEN
DIMENSIONS ARE TO BE FOLLOWED FOR CONSTRUCTION PURPOSES.
11. ALL CONSTRUCTION AND MATERIALS SHALL BE NEW, UNLESS OTHERWISE NOTED. ALL MATERIALS SHALL BE FURNISHED AND INSTALLED BY CONTRACTOR
UNLESS OTHERWISE NOTED.
12. ALL WORK OF THE VARIOUS TRADES INVOLVED WITH THE CONSTRUCTION OF THIS PROJECT IS TO BE PERFORMED BY CAPABLE AND REPUTABLE CONTRACTORS LICENSED IN THE STATE OF NEW YORK AND AS REQUIRED BY THE LOCAL GOVERNING AGENCIES.
13. NO WORK SHALL BE STARTED UNTIL A BUILDING PERMIT HAS BEEN SECURED AS REQUIRED BY THE APPLICABLE GOVERNING AGENCY OR AGENCIES.
14. ALL CONDITIONS AND DIMENSIONS SHALL BE VERIFIED BEFORE START OF ANY WORK AND DISCREPANCIES OR VARIATIONS TO APPROVED PLAN ARE TO BE
BROUGHT TO THE ATTENTION OF THE OWNER AND ARCHITECT BEFORE PROCEEDING.
15. PRIOR TO COMPLETION OF THE WORK CONTRACTOR SHALL REMOVE FROM THE JOB SITE ALL TOOLS, SURPLUS MATERIALS, EQUIPMENT, SCRAP, DEBRIS, AND
WASTE EXCEPT AS OTHERWISE NOTED BY THE OWNER.
16. ALL DIMENSIONS ON PLAN ARE NOMINAL. CRITICAL DIMENSIONS ARE NOTED "HOLD". FINISH DIMENSIONS WILL VARY IN ACTUAL CONSTRUCTION.
17. THE A.I.A. GENERAL CONDITIONS DOCUMENT A201 LATEST EDITION IS HEREBY MADE A PART OF THESE DOCUMENTS EXCLUDING ALL MENTION OF
ARCHITECTS OBSERVATION AND OWNER REPRESENTATION.
18. ALL LABOR AND MATERIALS SHALL CONFORM WITH THE REQUIREMENTS OF ALL LOCAL BUILDING LAWS AND ALL WORK SHALL BE CONSTRUCTED TO THE APPROVAL AND ACCEPTANCE OF THE BUILDING DEPARTMENT AT NO EXTRA COST; INCLUDING BUT NOT LIMITED TO GENERAL CONSTRUCTIONS, PLUMBING, HVAC, ELECTRICAL, ETC.
19. ANYTHING NOT EXPRESSLY SET FORTH IN THE DRAWINGS AND SPECIFICATIONS, BUT WHICH IS REASONABLY IMPLIED SHALL BE FURNISHED THOUGH NOT SPECIFICALLY INDICATED. FIGURES ARE TO BE TAKEN IN PREFERENCE TO SCALE. CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND SHALL NOTIFY
THE ARCHITECT IN WRITING OF ANY DISCREPANCIES BEFORE INSTALLING ANY WORK.
20. CONTRACTOR SHALL INSTALL MATERIALS IN ACCORDANCE WITH STANDARD TRADE PRACTICES AND MANUFACTURER AND TRADE ASSOCIATIONS
SPECIFICATIONS.
21. EXISTING GRADES AND SITE DIMENSIONS MAY VARY ON JOB FROM THOSE NOTED DUE TO FIELD CONDITIONS. CONTRACTOR SHALL NOTIFY ENGINEER IN
WRITING OF ANY DEVIATIONS OF SAME.
BRACING
22. ALL MASONRY AND FRAME WALLS SHALL BE ADEQUATELY BRACED AND SHORED DURING CONSTRUCTION UNTIL FULLY AND PROPERLY TIED BACK AND
CURED. FOLLOW CODE REQUIREMENTS AND GOOD CONSTRUCTION PRACTICES FOR SAME.
THERMAL AND MOISTURE PROTECTION, FLASHING AND CAULKING
23. ALL WINDOWS AND DOORS SHALL BE WEATHERSTRIPPED AND CAULKED. ALL SEALANT TO BE SILICONE, COLORED TO MATCH SURROUNDING MATERIAL.
24. FLASH ALL ROOF TO WALL CONDITIONS AND ALL WINDOW HEADS. ALL FLASHING SHALL BE NON-FERROUS METAL UNLESS OTHERWISE NOTED. PROVIDE
EXPANSION JOINTS AS REQUIRED FOR ALL METAL FLASHING.
25. SEALANTS AND CAULKING TO BE A POLYSULFIDE BASED COMPOUND AT THE FRAMES OF ALL OPENINGS IN THE EXTERIOR WALL, EXPANSION JOINTS AND ELSEWHERE. USE STANDARD COMPOUND CAULKING AT INTERIOR CAULKING CONDITIONS EXPOSED TO VIEW. USE PRIMERS AS RECOMMENDED BY
MANUFACTURER. PROVIDE ALUMINUM FLASHING AS NEEDED.
26. FLASH AROUND CHIMNEY, VENT STACKS, ALL ROOF PENETRATIONS AND WHEREVER ELSE REQUIRED WITH ALUMINUM, LAPPING ALL FLASHING AT LEAST 6".
ALL VALLEYS AND ROOF INTERSECTIONS WITH WALLS SHALL ALSO HAVE ALUMINUM FLASHING. PROVIDE FLASHING ABOVE DOORS, WINDOWS AND LOUVERS AND ALL OTHER OPENINGS. CAULK ALL EXTERIOR JOINTS. BUILDING SHALL BE GUARANTEED FULLY WATERTIGHT.
PROVIDE SEALANT AT ALL DISSIMILAR MATERIAL JOINTS.
MECHANICAL ENGINEERING GENERAL NOTES
A LICENSED PROFESSIONAL ENGINEER SHALL PROVIDE HVAC, PLUMBING, ELECTRICAL, SPRINKLER AND FIRE ALARM PLANS, SECTIONS, DETAILS, NOTES AND SPECIFICATIONS FOR THIS PROJECT. NOTES PROVIDED BY THE PROFESSIONAL ENGINEER SHALL SUPERSEDE THE GENERAL NOTES BELOW IF IN CONFLICT.
CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS AND APPROVALS FROM ALL AGENCIES AND JURISDICTIONS HAVING AUTHORITY OVER THIS PROJECT.
CONTRACTOR AND ALL TRADES ARE RESPONSIBLE FOR COMPLYING WITH ALL BUILDING CODES IN COMPLETENESS PERTAINING TO THIS PROJECT.
1. IF ANY EXISTING SERVICES NEED TO BE SHUT DOWN IN CONNECTION WITH THIS PROJECT, CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NOTIFICATIONS TO OWNER MINIMUM 7 DAYS PRIOR TO SHUTDOWN, APPROVALS AND PERMISSION AND PROVIDE TEMPORARY SERVICES AS REQUIRED. TENANT SPACES ARE TO REMAIN OPEN DURING CONSTRUCTION. GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY POWER AS REQUIRED.
2. WHERE PIPE OR DUCT PENETRATE RATED WALL, THE SPACE BETWEEN THE INSULATION AND THE WALL SHALL BE CAULKED WITH NON-COMBUSTIBLE MATERIAL IN AN APPROVED MANNER. ALL PIPING AND DUCT TO BE INSTALLED ABOVE HUNG CEILING UNLESS OTHERWISE NOTED. CONTRACTOR SHALL
COORDINATE WITH ARCHITECTURAL DWGS FOR ALL ELEVATIONS.
ELECTRICAL SYSTEM GENERAL NOTES
1. THE CONTRACTOR SHALL OBTAIN ALL PERMITS AND ARRANGE FOR ALL INSPECTION AND APPROVALS REQUIRED.
2. ALL TEMPORARY WIRING SHALL CONFORM TO NEC ART NO. 305 AND NEC SECTION B30.06.1. ELECTRICAL CONTRACTOR TO PROVIDE STAND-BY ELECTRICIAN
DURING TEMPORARY WIRING CONSTRUCTION.
3. SUBMISSION OF A BID, REPRESENTS THAT THE BIDDER HAS EXAMINED THE DRAWINGS, SPECIFICATIONS, AND OTHER CONTRACT DOCUMENTS, AND VISITED THE SITE OF THE WORK TO ASCERTAIN THE EXISTING CONDITIONS AND LIMITATIONS UNDER WHICH THE WORK IS TO BE PERFORMED, AND HAS INCLUDED IN THEIR BID A SUM NECESSARY TO PERFORM THE WORK AS SET FORTH IN THE CONTRACT DOCUMENTS. EACH BIDDER IS REQUIRED TO VISIT AND EXAMINE THE SITE, PRIOR TO SUBMISSION OF A BID, TO BE SATISFIED WITH ALL WORK CONDITIONS. CONTRACTORS CAN ONLY VISIT AND EXAMINE THE SITE BY SCHEDULING SITE VISIT WITH THE MHLS ON-SITE PROJECT MANAGER: CHRIS HERRON, FACILITIES MANAGER AT MID-HUDSON LIBRARY SYSTEM, 103 MARKET STREET, POUGHKEEPSIE, NY 12601.
845-471-6060 X 247. CHERRON@MIDHUDSON.ORG
4. ALL OPENINGS AROUND ELECTRICAL PENETRATIONS THROUGH FIRE RESISTANCE RATED CONSTRUCTION SHALL BE FIRE-STOPPED USING APPROVED
METHODS.
5. WHERE USED IN THIS DRAWING, "THE (THIS) CONTRACTOR", "ELECTRICAL CONTRACTOR" SHALL BE INTERPRETED AS THE PARTY OR PARTIES WHO HAVE BEEN DULY AWARDED THE CONTRACT FOR AND ARE THEREBY MADE RESPONSIBLE FOR ALL ELECTRICAL WORK. THE CONTRACTOR SHALL SUPPLY ALL NECESSARY LABOR, EQUIPMENT, AND MATERIALS REQUIRED TO PROVIDE A COMPLETE INSTALLATION (AS CONTEMPLATED IN THESE PLANS, WHETHER SPECIFICALLY SHOWN OR
NOT), AND IN COMPLIANCE WITH ALL GOVERNING BUILDING AND ELECTRIC CODES.
6. ALL WORK SHALL BE GUARANTEED AGAINST DEFECTS FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE OF THE INSTALLATION, AND ANY PORTIONS OF THE WORK WHICH DEVELOP DEFECTS DURING THAT TIME SHALL BE REPLACED OR REPAIRED.
7. ELECTRICAL CONTRACTOR SHALL PREPARE AND FURNISH COPY OF "AS BUILT" PLANS FOR ALL WORK INSTALLED TO THE OWNER. INCLUDE CATALOG CUTS, OPERATION AND MAINTENANCE MANUAL OF ALL EQUIPMENT INSTALLED.
8. 120 VOLT CIRCUITS RUN OF MORE THAN 90'-0" LONG SHALL BE INCREASED BY ONE SIZE.
9. CONTRACTOR SHALL REFER TO PLUMBING AND MECHANICAL DRAWINGS FOR LOCATION AND RATING OF EQUIPMENT REQUIRING ELECTRIC POWER. SIZE AND
LOAD REQUIREMENTS SHALL BE COORDINATED WITH EQUIPMENT PROVIDED IN FIELD.
PLUMBING GENERAL NOTES
1. THE CONTRACTOR SHALL FURNISH AND INSTALL A PLUMBING SYSTEM COMPLETE WITH ALL EQUIPMENT, PIPING, VALVES, INSULATION, CONTROLS, ACCESSORIES AND ASSOCIATED WORK IN ACCORDANCE WITH THE BUILDING CODE ALL AUTHORITIES HAVING JURISDICTION, AND THIS SPECIFICATION.
2. PLUMBING CONTRACTOR SHALL VERIFY ADA REQUIREMENTS AND COMPLY WITH ALL APPLICABLE BUILDING CODES.
3. THE WORK SHALL INCLUDE ALL LABOR, MATERIALS, EQUIPMENT, HOISTING AND RIGGING, SCAFFOLDING, AND SERVICES TO COMPLETE THE SYSTEM AND
PROVIDE THE OWNER WITH FULLY OPERATIONAL SYSTEM.
4. ALL WORK SHALL BE PROPERLY COORDINATED WITH THE OTHER TRADES TO AVOID CONFLICTS. REFER TO THE ARCHITECTURAL DRAWINGS AND PROVIDE
THE OWNER WITH A FULLY OPERATIONAL SYSTEM.
5. ALL NECESSARY CUTTING AND PATCHING IN FLOOR SLABS, ROOF SLABS, WALLS AND CEILINGS FOR THE PLUMBING WORK SHALL BE PERFORMED BY THIS
CONTRACTOR. RESTORE TO MATCH EXISTING CONDITIONS.
6. ALL MATERIALS AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE OF THIS WORK. ENGAGE THE SERVICES OF VARIOUS MANUFACTURERS' SUPPLYING THE EQUIPMENT FOR THE PROPER START-UP AND OPERATION OF THE PLUMBING SYSTEMS. INSTRUCT THE
OWNER'S PERSONNEL IN THE PROPER OPERATION AND SERVICING OF THE SYSTEM.
7. THIS CONTRACTOR SHALL SECURE ALL REQUIRED PERMITS AND APPROVALS AND TRANSMIT SAME TO THE OWNER. CONTRACTOR SHALL BE RESPONSIBLE
FOR ALL FEES.
8. SUBMIT A SEPIA AND TWO PRINTS OF THE PLUMBING LAYOUT SHOP DRAWING, CERTIFIED BY ALL TRADES THAT COORDINATION HAS BEEN ESTABLISHED.
SUBMIT PLUMBING FIXTURE CUTS WITH TRIM, INSULATION, VALVES AND FITTINGS, PIPE MATERIALS AND CERTIFIED EQUIPMENT CUTS WITH CONSTRUCTION WIRING DIAGRAM. SUBMIT FOUR (4) BOOKBOUND OPERATING AND SERVICE MANUALS, WHICH SHALL INCLUDE COPIES OF ALL SHOP DRAWINGS.
9. PROVIDE ACCESS DOORS IN GENERAL CONSTRUCTION WHICH WILL BE REQUIRED FOR THE PROPER OPERATION AND MAINTENANCE OF ALL CONCEALED EQUIPMENT, VALVES, AND OTHER SIMILAR DEVICES. PREPARE A LIST AND SUBMIT TO THE GENERAL CONTRACTOR FOR HIS INSTALLATION. ACCESS DOORS SHALL
BE A MINIMUM SIZE OF 12"X12", PIANO HINGE TYPE AND FIRE RATED FOR RATED WALLS.
10. ALL EXISTING SYSTEMS SHALL BE LEFT IN PERFECT WORKING ORDER UPON COMPLETION OF ALL NEW WORK.
11. EXACT SIZES AND LOCATIONS OF ALL EXISTING PIPING SHALL BE VERIFIED ON THE SITE.
12. NO REMOVED EXISTING PIPING SHALL BE REUSED UNLESS OTHERWISE INDICATED.
13. THIS CONTRACTOR SHALL NOT INTERRUPT ANY OF THE SERVICES OF ANY EXISTING BUILDING NOR INTERFERE WITH THE SERVICES IN ANY WAY WITHOUT THE EXPRESSED PERMISSION OF THE OWNER. SUCH INTERRUPTIONS AND INTERFERENCES SHALL BE MADE AS BRIEF AS POSSIBLE AND ONLY AT THE SUTIED BY THE
OWNER.
14. UNDER NO CIRCUMSTANCES WILL THIS CONTRACTOR OR HIS WORKMEN BE PERMITTED TO USE ANY PART OF THE BUILDING AS A SHOP, EXCEPT PART
DESIGNATED BY THE OWNER FOR SUCH PURPOSES.
15. UNNECESSARY NOISE SHALL BE AVOIDED AT ALL TIMES AND NECESSARY NOISE SHALL BE REDUCED TO A MINIMUM.
16. WHERE THE WORK MAKES TEMPORARY SHUT DOWN OF SERVICES UNAVOIDABLE, THEY SHALL BE MADE AT NIGHT OR AT TIMES AS THIS WILL CAUSE THE LEAST
INTERFERENCE WITH THE ESTABLISHED OPERATING ROUTINE OF THE BUILDING.
17. THIS CONTRACTOR SHALL ARRANGE THE WORK CONTINUOUSLY, INCLUDING APPROVED BY THE ARCHITECT OVERTIME IF REQUIRED, TO ASSURE THAT SERVICES WILL BE SHUT DOWN AND CUT-INS ONLY DURING THE TIME ACTUALLY REQUIRED TO MAKE THE NECESSARY CONNECTION TO EXISTING WORK.
18. THIS CONTRACTOR SHALL GIVE AMPLE WRITTEN NOTICE IN ADVANCE TO THE OWNER OF ANY REQUIRED SHUT DOWNS.
19. TO ENSURE CONTINUOUS OPERATION, MAKE ALL NECESSARY TEMPORARY CONNECTIONS BETWEEN NEW AND EXISTING WORK. ALL COST RESULTING FROM
TEMPORARY SHUTDOWNS SHALL BE BORNE BY THIS CONTRACTOR.
SLEEVES AND ESCUTCHEONS FOR PIPING
1. PROVIDE SLEEVES FOR PIPES PASSING THROUGH WALL PARTITIONS AND FLOORS.
2. CAULK SPACE BETWEEN PIPE AND PIPE INSULATION WITH NON-COMBUSTIBLE MINERAL WOOL TO WITHIN 1/2" OF WALL FACES AND FILLED WITH CAULKING
COMPOUND TO WALL SPACES.
3. PROVIDE ESCUTCHEONS ON EXPOSED PIPING THROUGH WALLS OR FLOORS WITH SET SCREWS OR INTERNAL SPRING TENSION.
ABBREVIATIONS:
# POUND OR NUMBER
& AND
@ AT
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLER UNIT
ALUM ALUMINUM
BSMT BASEMENT
BYND BEYOND
B.O. BOTTOM OF
CJ CONTROL JOINT
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CT CERAMIC TILE
DBL DOUBLE
DEMO DEMOLISH OR DEMOLITION
DIA DIAMETER
DIM DIMENSION
DIMS DIMENSIONS
DN DOWN
DR DOOR
DWG DRAWING
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR OR ELEVATION
EPDM ETHYLENE PROPYLENE DIENE
M-CLASS (ROOFING)
EQ EQUAL
EXIST EXISTING
EXP JT EXPANSION JOINT
EXT EXTERIOR
FD FLOOR DRAIN
FIXT FIXTURE
FLR FLOOR
FO FACE OF
FND FOUNDATION
GA GAUGE
GALV GALVANIZED
G.C. GENERAL CONTRACTOR
GWB GYPSUM WALL BOARD
HP HIGH POINT
HVAC HEATING, VENTILATING,
AND AIR CONDITIONING
IRGWB IMPACT RESISTANT GYPSUM
WALL BOARD
INSUL INSULATED OR INSULATION
INT INTERIOR
MAX MAXIMUM
MO MASONRY OPENING
MECH MECHANICAL
MIN MINIMUM
MR GWB MOISTURE-RESISTANT
GYPSUM WALL BOARD
MTL METAL
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OAE OR APPROVED EQUAL
OC ON CENTER
OH OPPOSITE HAND
OZ OUNCE
PLUMB PLUMBING
PLYD PLYWOOD
PT PRESSURE TREATED
PNT PAINT OR PAINTED
PVC POLYVINYL CHLORIDE
RBR RUBBER
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REQD REQUIRED
RM ROOM
SIM SIMILAR
SPEC SPECIFIED OR SPECIFICATION
SSTL STAINLESS STEEL
STC SOUND TRANSMISSION
COEFFICIENT
STL STEEL
STRUCT STRUCTURE OR STRUCTURAL
T&G TONGUE AND GROOVE
TELE TELEPHONE
TLT TOILET
T.O. TOP OF
TOC TOP OF CONCRETE
TOS TOP OF STEEL
TPD TOILET PAPER DISPENSER
T/D TELEPHONE/DATA
TYP TYPICAL
U.N.O. UNLESS NOTED OTHERWISE
U/S UNDERSIDE
VIF VERIFY IN FIELD
W/ WITH
WD WOOD
SHEET NO.
PROJECT NO.
DATE
DRAWN BY
IT IS UNLAWFUL TO MODIFY A DOCUMENT BEARING THE SEAL AND
SIGNATURE OF A REGISTERED ARCHITECT OR PROFESSIONAL ENGINEER
NOTE:
IN
IT
IA
L
P R
IC
IN
G P
LA
N
D R
A W
IN
G
S F
O R
M
ID
H U
D S
O N
L
IB
R A
R Y
S
YS
TE
M
M A
R K
E T
S
TR
E
U
G H
K E
E P
S
IE
, N Y
DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS TAKE PRECEDENCE.
IN CASE OF DISCREPANCIES OR CONFLICTS, NOTIFY DESIGN PROFESSIONAL.
P O
B O
X
K
IN
G
S
TO
N N
Y in fo sy ne rg yd es ig n.
or g
Y N E R G Y
E S
IG
N
A R
C H
IT
E
C
TU
R E
E
N G
IN
E
E R
IN
G
P
LL
C
IN
ITI
AL
PRIC
IN
G SE
T -
NOT F
OR C
ONSTRUCTIO
N
26-113
SH, JV
14 OCT 2026
REV. DATE
N
N O
TE
S
| Sheets and Views |
| SD MHLS 103 Market St Office Building Renovation 2026 10 14-A |
| SD MHLS 103 Market St Office Building Renovation 2026 10 14-EX-1 |
| SD MHLS 103 Market St Office Building Renovation 2026 10 14-A-1 |
| SD MHLS 103 Market St Office Building Renovation 2026 10 14-A-2 |
| SD MHLS 103 Market St Office Building Renovation 2026 10 14-A-3 |
| SD MHLS 103 Market St Office Building Renovation 2026 10 14-A-4 |
| SD MHLS 103 Market St Office Building Renovation 2026 10 14-RCP-1 |
| SD MHLS 103 Market St Office Building Renovation 2026 10 14-E-1 |
| SD MHLS 103 Market St Office Building Renovation 2026 10 14-ED-1 |
| SD MHLS 103 Market St Office Building Renovation 2026 10 14-ED-2 |
| SD MHLS 103 Market St Office Building Renovation 2026 10 14-ED-3 |
| SD MHLS 103 Market St Office Building Renovation 2026 10 14-N-COM |
File details come from the government source that posted it. Updated .