Scope of work.pdf

PDF 315 KB Posted

Attached to
CSC-24911 Building 20 Lighting Supplies
Solicitation number
SP4702-24-Q-0030
Issued by

About this file

This document appears to be a Scope of Work for a federal contract opportunity. The contract is for the purchase of lighting supplies, including 2G11 PLL lamps, T8 ballast bypass retrofit lamps, can fixtures, and emergency backup ballasts. The quantities and salient characteristics of the required items are detailed.

The related federal contract opportunity is Solicitation SP4702-24-Q-0030, issued by the Defense Logistics Agency, for the CSC-24911 Building 20 Lighting Supplies project. The supplies will be used by in-house electricians to complete lighting repair work in Building 20 at the Defense Supply Center Columbus in Columbus, Ohio. The supplies are required to be delivered to DSCC Building 17 at the specified address.

View the file

Other files

File Type Posted
Solicitation Questions.pdf PDF
SF30-Amendment 001.pdf PDF
SP4702-24-Q-0030.pdf PDF
BID SHEET.xlsx XLSX spreadsheet

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Item Quantities:

Salient Characteristics:

Material Descrip�on Color Lumens Retrofit

Type Base Type Length/

Diameter Wattage Voltage CRI L70 Output

Voltage Output

Wattage Emergency

Opera�on Time

2G11 PLL Lamp 4000K 2800 N/A 2G11 21.8 in 23 120 - 277V 82 100000 N/A N/A N/A 3 � T8 Ballast Bypass Retrofit Lamp 4000K 1440 Type B T8 36 in 11.5 120 - 277V 83 54000 N/A N/A N/A 4 � T8 Ballast Bypass Retrofit Lamp 4000K 2200 Type B T8 48 in 17 120 - 277V 82 54000 N/A N/A N/A 6" CAN 5000K Fixture 5000K 1150 N/A CAN 6 in 14 120 - 277V 90 50000 N/A N/A N/A 8" CAN 5000K Fixture 5000K 1800 N/A CAN 8 in 20 120 - 277V 90 50000 N/A N/A N/A 8" CAN 4000K Fixture 4000K 1800 N/A CAN 8 in 21 120 - 277V 90 50000 N/A N/A N/A Emergency Backup Ballast for 4 � T8 Retrofit Lamps as required 4000K N/A N/A N/A N/A N/A 120 - 277V N/A N/A 40-100 VDC 10 90 minutes

*NOTE: All items must support mul�ple voltages from 120-277 V

Lamp/Fixture Type Quantity Unit 2G11 PLL Lamp 5,392 EA 3 � T8 Ballast Bypass Retro 739 EA 4 � T8 Ballast Bypass Retro 2,312 EA

6" CAN 5000K 287 EA

8" CAN 5000K 277 EA

8" CAN 4000K 1,263 EA

Emergency Backup Ballast for 4 � T8 Retrofit Lamps as required 185 EA

Project CSC-24911 requires the purchase of lighting supplies. The purchased supplies will be used by in house electricians to complete lighting repair work throughout Building 20. The supplies shall be delivered to DSCC Building 17, 3990 E Broad Street Columbus, OH 43213

File details come from the government source that posted it. Updated .